Home
        Quick Installation Guide - Promise Technology, Inc.
         Contents
1.      Quick Installation Guide    Supertrak100 Controller Card    The Supertrak100 controller card has several physical features of interest for  purposes of installation  A SIMM socket for EDO memory  6 IDE channel  connections  1    master    drive per channel   an alarm buzzer  a battery  and 4 LEDs  on the card   s backplane     NOTE  The Supertrak100 controller card  like every other valuable part of your PC   is sensitive to static electricity  Be sure that you are properly grounded  Promise  recommends that you wear an antistatic strap  or place a free hand on a grounded  object   and that your PC is unplugged before installing any of the Supertrak100  components            EDO Simm Stot            Onboard CPU      UDMA 100  LEDs ASIC    Supertrak100 controller card    Cables    Ultra ATA 66 100 drive cables are provided with the Supertrak100 controller card   These cables must be used with Ultra ATA 6 or UltraATA 100 drives in order to  realize full Ultra ATA 66 100 specs  They differ from older 40 wire 40 pin IDE cables  by adding an extra ground wire between each data wire  resulting in an 80 wire 40   pin cable     Quick Installation Guide    Install Hardware    1  Install 16MB EDO memory into the SIMM slot on card     2  Remove protective label for 3V  CR2032 or compatible  battery shipped with the  card that supports NVRAM  Remove protective label for audible alarm buzzer        Typical controller card installation    4  Install the controller card into an availab
2.    SuverTRak iy    Quick Installation  Guide    Quick Installation Guide    This guide is designed to help you quickly install Supertrak100 and configure your  RAID array into a Windows NT 4 0 or Windows 2000 host system  Please read  through this guide carefully before attempting to install Supertrak100  The steps  are as follows     Unpack Supertrak100   Install Hardware   Build Array   Install SuperTrak100 Windows Driver  Install SuperCheck Components  Check TCP IP Settings    D ODN  gt     If you have any questions about these steps  consult the main User   s Manual     NOTE  Users should record their current CMOS  system setup  settings before  making any changes  This preventative measure is aimed at protecting such  information from loss  which may happen unpredictably and or periodically during  any hardware installation     Unpack Supertrak100    The Supertrak100 package should contain the following items     Supertrak100 controller card   Supertrak100 User   s Manual    1  16MB 72 pin EDO SIMM   Supertrak100 OS drivers  amp  utility diskettes  3    Internal 18    Ultra ATA 100 80 wire 40 pin hard drive cables  6     If any of the items are missing or appear damaged  please contact your dealer or  distributor immediately     NOTE  The Supertrak100 controller card ships with two removable protective  labels that cover the audible alarm buzzer device and the battery which maintains  the non volatile RAM memory  These labels must be removed prior to installing the  card
3. d click on    Run       from the Start  Menu  Type in  AAsetup exe     3  The main SuperCheck component installation menu will appear     SUperChech    SUPCICHECK    SUPCICNECK    SoperChech    SUPEICHECK S  Superenech    Superenech      SuperCheck Setup screen       E  Install Monitoring Utility    E gt   Install Message Server   amp  1 install Massage Agent  4 Install Al Components  E 5 Visit www promise com    cP bh Est       Select  4 Install All Components   Reboot the system AFTER all software components have been installed in  order to activate any installed NT services    6  If you want to monitor the Supertrak100 from another PC s  running Win  95 98 NT 2000 in your network  install just the SuperCheck Monitoring Utility  component on to this system s      Check TCP IP Settings   Proper TCP IP setup is crucial for the Supertrak100 software package to function  correctly  Without TCP IP installed and configured correctly  the monitoring  software will not be able to make connections to the Supertrak100 RAID server     Use the IP address for which your Windows NT host system  the server containing  Supertrak100  is already configured to establish connections  Otherwise  use IP  address 127 0 0 1 for all your TCP IP configurations  this address will allow all  TCP IP requests to remain within the system     P N  C6105ST10000000    
4. em  Windows 2000  setup will show a    New Hardware Found    dialog box     1     7   8     In the dialog box  choose    Driver from disk provided by hardware manufacturer     button     Check    Search for a suitable driver for my device  recommended     and then  click the    Next    button     In the    Locate Driver Files    dialogue box uncheck    Floppy Disk Drives     check     Specify a location     and then click the    Next    button     In the A  drive  insert the SuperTrak100 driver diskette   Type    A WIN2000    in the text box  Press    Enter           Windows2000 Promise SuperTrak66 100 IDE RAID Controller    should be found   Click the    Next    button     Click the    Yes    button in the    Digital Signature Not Found    dialogue box   Click on the    Finish    button and reboot the system     Confirming Windows 2000 Installation    1     From Windows 2000  open the Control Panel from    My Computer    followed by  the System icon   Choose the    Hardware    tab  then click the    Device Manager    tab     Click the         in front of    SCSI and RAID controllers   Windows2000 Promise  SuperTrak66 100 IDE RAID Controller    should appear     Installing Driver During New Windows 2000 Installation  1a  Floppy Install  Boot the computer with the Windows 2000 installation diskettes   1b  Floppyless Install  Boot from floppy and type    WINNT     After files have been    copied  the system will reboot  On the reboot  press  lt F6 gt  after the message     Pres
5. enu and manually assign the  exact number of drives you want included  See User   s Manual     SuperBuild firray Utility 1 00 Copyright CC  1999 Promise Technology  Inc       fiuto Setup Options Menu    Optimize firray for  RAIDS      Array Setup Configuration      MORI ZAIRE CANE RA anice Data Parity Striping    Spare Drive  Drive s  Used in firray    Array Disk Capacity  size in MB       Reys Available     3    Up  i    Down        Space   Change Option  ESC   Exit  Ctrl Y   Save       Auto setup screen    Quick Installation Guide    Install Windows NT or 2000 Driver    At this point  you will be installing the Promise drivers into an existing Windows NT  or 2000 system  on a boot drive that is separate from the SuperTrak array  or you  will begin installing Windows NT or 2000 from scratch     Installing Driver in Existing Windows NT 4 0 System    oar wh  gt     11     From the    Start    menu  choose    Control Panel    in the    Settings       In the    Control Panel    window  double click on the    SCSI Adapters    icon   In the    SCSI Adapters    window  choose the    Drivers    tab    Press the    Add    button    Choose    Have Disk    in the    Install Driver    window  insert Driver diskette     Enter the directory location of the driver in the text box  A  or use browse  button to locate file      Click on the filename    sptrak inf    and press    Open    button   Select    WinNT Promise SuperTrak66 100 Controller    and press    OK           Select SCSI Adapte
6. le PCI slot on the system motherboard  and secure it in place     5  Set the hard drives to  Master    Cable Select   or    Single     depending on drive  specification     6  Next  install hard drives into the PC chassis  Attach black end of Ultra  ATA 66 100 cable and power cable to back of each drive  Connect the blue end  of the Ultra ATA 66 100 cable to any IDE channel available on the  Supertrak100     NOTE  Device support for drives is provided by the Supertrak100 system  No  changes are necessary in the motherboard CMOS BIOS Setup for resources or  drive types regarding hard drive configuration  Changes may or may not be  necessary for PCI device setup     Quick Installation Guide    Build Array   Boot the system  You will see the Promise BIOS sign on banner appear on the  screen  Press  Ctrl F  to initialize SuperBuild and display the Main Menu   Creating a disk array from the Auto Setup screen   1  From the Main Menu press  1  to display the Auto Setup screen     2  Choose an option in the    Optimize array for     field  The choices offered are  RAID 0  striping   RAID 1  mirroring   RAID3  striping w  dedicated parity   and  RAID5  data striping w  striped parity   and JBOD  spanning array     3  Press the  Ctrl Y  keys  SuperBuild will build an array automatically from the  hard drives connected to the Supertrak100 controller     NOTE  Auto setup does not allow configuring a hot spare drive  If you wish to have  a spare drive  you must use the View Define Array M
7. r Option    will be displayed  Press    Install     which initiates  the installation operation       After a successful installation  the    SCSI Adapter Setup    dialog box will appear    which states that the     WinNT Promise SuperTrak66 100 Controller    has been  installed     Restart the system     Installing DriverDuring New Install of Windows NT 4 0    1  a  Floppy Install  Boot the computer with the Windows NT installation  diskettes   b  Floppyless Install  Boot from floppy and type    WINNT  B     After files  have been copied  the system will reboot  On the reboot  press  lt F6 gt  when  the message    Setup is inspecting your computer   s hardware  configuration       appears   c  CD ROM Install  Boot from the CD ROM and press  lt F6 gt  when the  message    Setup is inspecting your computer s hardware configuration           Press    S    to add the Supertrak100 controller    Select    Other  requires disk provided by hardware manufacturer        Insert the Promise driver diskette into drive A  and press ENTER    Select the    WinNT Promise SuperTrak66 100 Controller    and click    OK        ak WD    Quick Installation Guide    NOTE  for CD installations  you must also specify the driver for your CD ROM  adapter  i e  if using an ATAPI CD ROM  specify the IDE 2 1 controller     6  Follow the normal setup installation procedure     Windows 2000    Installing Driver in Existing Windows 2000 System    After installing the Supertrak100 card and rebooting your syst
8. s F6 if you need to install third party SCSI or RAID driver    appears     Quick Installation Guide    1c  CD ROM Install  Boot from the CD ROM  Press  lt F6 gt  after the message    2        Press F6 if you need to install third party SCSI or RAID driver    appears    When the    Windows 2000 Setup    window is generated  press    S    to Specify an  Additional Device s    Insert the Promise Technology    driver diskette into drive A  and press    Enter     key    Choose    Win2000 Promise SuperTrak66 100 Controller    from the list that  appears on screen  then press the    Enter    key    The Windows 2000 Setup screen will appear again saying    Setup will load  support for the following mass storage devices  The list will include  Win2000  Promise SuperTrak66 100 IDE RAID Controller        NOTE  If you need to specify any additional devices to be installed  do so at  this time  Once all devices are specified  continue to step 6     From the Windows 2000 Setup screen  press the Enter key  Setup will now  load all device files and then continue the Windows 2000 installation     Quick Installation Guide    Install SuperCheck Components    This section explains the installation of components to run SuperCheck on a single  file server housing a Supertrak100 array within a local area network  For more  complex installations  see the User   s Manual     1  Insert the    SuperCheck Install Diskette Number 1    into the floppy drive   2  From Windows NT  go to the Start button  an
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
10584 NSBT-210  Click&DECiDE Business Application Intelligence  iP-01L/iP-02シリーズ/iP  PREFEITURA MUNICIPAL DE MATINHOS    Sweex CR005V4OEM card reader  KWA Kriss Vector  Réfractomètres Brixxus® CRI 204|CRI 265  Dell PowerEdge M420-Systeme Benutzerhandbuch  High Performance    Copyright © All rights reserved. 
   Failed to retrieve file