MEC 32 Instruction Manual - Digital Advanced Control

image

Contents

1. module is in quiet mode between 0 100 The Quiet mode selection can be adjusted in the timed event settings These parameters allow you to set up the functionality of the scrolling arrows This selects the type of direction arrow to be displayed These parameters allow you to set the scrolling speeds of the indicators This parameter selects the speed of the scrolling position This parameter selects a speed of the scrolling messages This parameter selects the speed of the scrolling arrows These parameters allow you to set the functionality of Hall arrow and gongs This parameter selects the type of hall arrow to be displayed 1 6 2 0 Hall Gong This parameter if set to yes turns Y Britain Unit2 Faraday Close Daventry Northamptonshire NN11 8RD enquiries digital advanced control co uk 23 Tel 44 0 1327 879334 INDICATOR CONTROL CARD USER MANUAL 1 6 3 0 Car Gong This parameter if set to yes turns on the car gong only 1 7 1 0 No Entry Setup This parameter sets if message input Displays the NO ENTRY Symbol 2 0 0 0 Board Management These parameter set the Board configuration Parameters 2 1 1 0 Date And Time This parameter sets the time and date of the real time clock for displaying the time on the Clear View indicators 2 1 1 0 DLight Saving This parameter sets if the day light saving is ON or OFF 2 2 0 0 ICC Test Modes These parameters set up the self test mo
2. 10 Relay Board Input Voltage 24VDC 10 Indicator Control Card the Indicator Control Card consumption Internal Voltages 5V 3V3 and 1 8V Microprocessor Specification Microprocessor Type 32Bit RISC Microcontroller with a MIPS32 M4A4K core operating at 60MHz and 90MIPS Can Ports 1 Can ports operating at 250Kbits Sec with a maximum bus length of 200m terminated by 1200 resistor Real Time Clock Super accurate real time clock with an internal temperature compensated clock frequency with a drift of 3ppm Display 4x20 STN Alphanumeric White On Blue LCD Display with LED Backlight Dimensions 195mm x 115mm x 40mm Weight 250 grammes 12 24V DC inputs Can be switched positively and negatively draw 5mA each input Unit2 Faraday Close Daventry A Northamptonshire NN11 8RD Britain enquiries digital advanced control co uk Tel 44 0 1327 879334 INDICATOR CONTROL CARD USER MANUAL Operational Temperatures Maximum Operating Temperature Maximum Ambient Temperature Minimum Operating Temperature 60 C 40 C 10 C EMC Compliance Emissions BS EN12015 2004 Lifts Escalators amp Passenger Conveyors BS EN55022 2006 A1 2007 Class A Emissions Standard for Information Technology Equipment BS EN12016 2004 Lifts Escalators amp Passenger Conveyors BS EN61000 4 2 1995 Electrostatic Discharge BS EN61000 4 3 2002 Radiated Immunity BS EN61000 4 4 1995 Fast Transient B
3. P2 2 PAGE 1of4 Press the Enter button to confirm the change to G and the character will stop flashing Northamptonshire NN11 8RD Britain enquiries digital advanced control co uk Tel 44 0 1327 879334 f Unit2 Faraday Close Daventry 1 5 BM TRADA CERTIFICATION ISO 9001 2008 INDICATOR CONTROL CARD USER MANUAL SBI SP2 ONIRU III pI G ID gt Z lt PAGE lof4 Press the DN button to scroll to the next parameter and repeat the previous to change TINIZIUNE ELOR DIL G DZ SS PAGE lof4 Press the SETUP button to Return to the screen 16 YSP 11 11 VER 1 0 INDICATOR CONTROL CARD USER MANUAL 5 2 ICC Menu Structure Indicator Setup SETUP Indicator Setup Position Setup UP DN UP DN Factory Setup UP DN UP DN tit UP DN UP DN ICC Test Mode UP DN Scroll Speeds UP DN HL amp Gong Setup UP DN No Entry Setup WA Unit2 Faraday Close Daventry 1 7 A Northamptonshire NN11 8RD Britain enquiries digital advanced control co uk Tel 44 0 1327 879334 5 3 INDICATOR CONTROL CARD USER MANUAL ICC Menu Structure Factory Setup Indicator Setup UP DN SETUP Factory Setup ki a UP DN as E Nin Reset Eng Pass UPZDN UP DN ICC Test Mode UP DN About Programme Version YSP 11 11 VER 1 0 18 INDICATOR CONTROL CARD USER MANUAL 5 4 ICC Menu Structure Board Management Indicator Setup UP DN Fac
4. V and is supplied from 3 3 V The board is a 4 layer board and has separate power and ground planes internally sandwiched inside the board C A N drivers The microprocessor board has a controller area Network C A N device to implement a network for controlling the indicators The communication is at 250K bits s and uses the Peli Can V2 0B mode with 11 bit identifiers The transceiver is a MCP2551 CAN chip on the left hand side of the board LED indication of the network is provided when the LEDs are flashing brightly at a rate of 1 Hz this indicates there is no bus communication with the indicator devices If the LEDs flash WA Unit2 Faraday Close Daventry A Northamptonshire NN11 8RD Britain enquiries digital advanced control co uk Tel 44 0 1327 879334 INDICATOR CONTROL CARD USER MANUAL dimly and at a much faster rate then communication with the indicator devices is successful Contrast potentiometer The contrast of the display of the microprocessor can be adjusted by the contrast pop located on the top left hand side of the microprocessor Speech Unit The indicator control card has an on board speech unit included This provides a digitised speech output with a carrier frequency of 21 6 kHz The digitised speech is filtered and then amplified using the latest D Class amplifier technology allowing for a heat sink less design compact size and clarity of sound YSP 11 11 VER 1 0 INDICATOR CONTROL CARD USER MAN
5. to give indication of successful communication and operation of the card Setup menus are accessed via the operator interface which is designed to be both flexible and user friendly WA Unit2 Faraday Close Daventry 5 A Northamptonshire NN11 8RD Britain enquiries digital advanced control co uk Tel 44 0 1327 879334 INDICATOR CONTROL CARD USER MANUAL CH CL NETX AC DC Input Serial data C A N output o ooo EZAN Speaker output M1 M2 M3 M4 M6 M7 DOI DCI speech input doors closing PT SX HU M5 Lift out of Service 12 24V PC P1 P8 Loop Led If not beating then the microprocessor has failed YSP 11 11 VER 1 0 INDICATOR CONTROL CARD USER MANUAL Real time clock The real time clock is provided by a super accurate real time clock with an internally temperature compensated calibrated clock to ensure the real time clock is accurate to or 3 5 ppm This Real time clock includes the minutes hours day date month and year information This automatically adjusted for months with fewer than 31 days including corrections for the leap years The clock operates in a 24 hour format and a 3 2v battery which provides backup of the time and date Should be changed every 5 years Power supply The power supply to the unit is from 12 24 V DC utilising a DC to DC switch mode power supply is reduced to 5V and 3 3V on the board the microprocessor has its own on board regulator for generating the 1 8
6. Giri Goni l Indicator Control Card User Manual CERTIFICATION i Y 012 Made in Britain INDICATOR CONTROL CARD USER MANUAL Contents I Introduction 4 1 0 Standard FeaturesS 4 2 Indicator Control Card Layout 5 3 Electrical Con ections LLULLU S asss 9 4 Indicator Control Card MMI Ilnterface 10 5 Changing A Parameter 12 5 1 Example of changing the position from 1 to G 13 5 2 ICC Menu Structure Indicator Setup 17 5 3 ICC Menu Structure Factory Setup 18 5 4 ICC Menu Structure Board Management 19 5 5 ICC Menu Structure ICC Test Mode 20 5 6 ICC Parame lel ten 21 6 Maintenance Required 25 Appendix A Electrical amp Mechanical Data 27 YSP 11 11 VER 1 0 INDICATOR CONTROL CARD USER MANUAL Revision History By 01 09 2011 Initial Deployment WA Unit2 Faraday Close Daventry A Northamptonshire NN11 8RD Britain enquiries digital advanced control co uk Tel 44 0 1327 879334 INDICATOR CONTROL CARD USER MANUAL 1 Introduction The SF750 indicator control card has been designed to act as an interface between a lift controller and the Digital Advanced Control range of dot matrix indicators an
7. SEVEN SEG Seven Segment Sets the lowest level of the lift inputs Sets the number of floors of the Lift Set the intensity level of the indicators 21 Tel 44 0 1327 879334 INDICATOR CONTROL CARD USER MANUAL 1 1 6 0 Display Zero Position 1 2 0 0 Message Setup f 1 3 0 0 Speech Setup 1 3 1 0 Announce All FL 1 3 2 0 Speech Volume Displays a base position with no inputs set up the messages This parameter allows the message to be written for each message input i e When the microprocessor outputs lift overloaded the standard message of lift overloaded will be displayed this could be changed to lift overloaded please reduce the load The lift overloaded message which is message one will only ever be displayed on the car These parameters allow you to set up the functionality of the speech module This parameter is set when announcing of the floors is required as each floor is passed without a speech position trigger This parameter adjusts the level of the volume from the speech module between 0 100 1 3 3 0 Quiet volume This parameter adjusts the level of the volume when the speech YSP 11 11 VER 1 0 22 INDICATOR CONTROL CARD USER MANUAL 1 4 0 0 1 5 0 0 1 5 1 0 Position scroll speed Direction arrow type Scroll speed setup 1 5 2 0 Message scroll 1 5 3 0 Arrow scroll speeq 1 6 0 0 Hall arrow and Gong set up 1 6 1 0 Hall arrow type
8. UAL 3 Electrical Connections 33 s A 5 DS Position Inputs Wod UOl ISOcJ Woy ebessay UMO Jy O49S dn iv O49S UMO MOV eH dn mouy EH x RIGHT el e DOWN SETUP LEFT ENTER RIGHT 4186611 uonisoq so O 4000 uado J00g CONTROL 04 00 OV 31927 EVSA SE7590 CAN INDICATOR TE CLIE LLLLELLLD DIGITAL ADV I8 04 10 Fri 44 CAR INDICATOR WA Unit2 Faraday Close Daventry A Northamptonshire NN11 8RD Britain enquiries digital advanced control co uk Tel 44 0 1327 879334 INDICATOR CONTROL CARD USER MANUAL 4 Indicator Control Card MMI Interface Operator Keypad POSITION INPUT ENERGISED DIGITA ADVANCED CONIMROIL M 0 S 00000000 MESSAGE INPUT ENERGISED SPEECH amp INDICATOR OPERATION INPUT ENERGISED pt SPEECH amp INDICATOR OPERATION INPUTS MESSAGE POSITION INPUTS INPUTS The MMI interface of the MEC32 is a Alphanumeric character LCD display which has 5 push buttons to navigate the setup menus The buttons are configured in an intuitive arrangement similar to most modern day mobile phones allowing for ease of operation 10 YSP 11 11 VER 1 0 INDICATOR CONTROL CARD USER MANUAL The buttons are as follows UP UP browse adjust parameter button DN DOWN browse adjust parameter button LEFT Left browse button RIGHT Right browse button ENTER Confirm Enter button SETUP gives access to the conf
9. anging the position at a floor is shown in the diagrams overleaf 12 YSP 11 11 VER 1 0 INDICATOR CONTROL CARD USER MANUAL 51 Example of changing the position from 1 to G SP1 SP2 MAIN MENU 1 2 Sil Minehlecicose Seo 2 Faectory Setup 3 Board Management Press The SETUP Button to Select The Setup menus Position Setup 1 2 Silos Tipu Serup 2 Pos Input Type So mes Level Press the ENTER button to select the position setup menu Northamptonshire NN11 8RD Britain enquiries digital advanced control co uk Tel 44 0 1327 879334 f Unit2 Faraday Close Daventry 1 3 INDICATOR CONTROL CARD USER MANUAL SPA SP2 INPUT FLOOR PI gt lt DZ 2 PAGE lof4 O O O TX E ae Press the ENTER button to select the position input setup menu SP1 SP2 PNEU FLOOR Pal gt Is os BZ PAGE 1of4 O O c MS M1 M2 M3 M4 M5 M6 M7 M8 DOI DCI PT SX HU HD IU ID MC E P1 P P3 P4 P5 P6 P7 P8 gt i gt Q N Press the ENTER button and the position will flash signaling the parameter can be changed CERTIFICATION ISO 9001 2008 YSP 11 11 VER 1 0 INDICATOR CONTROL CARD USER MANUAL SS CN fel Yak nn UP LEFT ENTER TINIZIONE oye PI gt _ES os PZ 2 DOW PAGE lof4 Press the UP button to change the position to G e gt CN s nw UP INPUT FLOOR LEFT ENTER RIGH PI gt G lt
10. d TFT LCD screens The indicator control card is a fully featured programmable unit which includes speech real time and date full opto isolation and controller area network C A N communication The unit is operated from 12 24 V A C or D C and it s a small compact unit designed to fit on DIN Rail 1 0 Standard Features e A user friendly interface to allow changes to be made to the indicators and TFT displays on site e Programmable inputs including line per floor binary grey code inverted binary and seven segment inputs e Input monitoring via the on board liquid crystal display e Real time and date from a super accurate real time clock e Positive and negative common inputs as standard e Self test features to simplify commissioning e Controller area network C A N e Onboard speech as standard e Designed manufactured and technical support in the UK YSP 11 11 VER 1 0 INDICATOR CONTROL CARD USER MANUAL 2 Indicator Control Card Layout Speaker Contrast Pot Operator Keypad Connections L C D Display DIGITAL ADV CONTROL 24 0 1327 879334 SF750 CAN INDICATOR 18 04 10 Fri 04 00 Speech EPROM C A N Transceiver Serial Data Output Controller Input Posi FUSE Input Power Supply Connections Connections Connections The indicator control card consists of a main PCB board which includes power and input stages connections for communication and a speaker a LCD and an operator keypad There are LED s
11. des of the Indicator Control Card 2 2 1 0 Position Check This parameter displays the position on the position indicators automatically 2 2 2 0 Message Check This parameter displays the messages automatically on the indicators YSP 11 11 VER 1 0 24 INDICATOR CONTROL CARD USER MANUAL 2 2 3 0 Speech Check This parameter checks the speech and speaker operation 2 2 4 0 No Entry Check This parameter will display the NO ENTRY Sign on the indicators when set WA Unit2 Faraday Close Daventry 5 A Northamptonshire NN11 8RD Britain enquiries digital advanced control co uk Tel 44 0 1327 879334 INDICATOR CONTROL CARD USER MANUAL 6 Maintenance Required The Indicator Control Card its self is a solid state device has few user serviceable parts and requires little maintenance but the indicator control card will require the following to be done with the power off Note Electronic boards contain static sensitive devices and should not be touched unless you have the required protection Every 5 7 Years Change the Battery in the Microprocessor Date Changed Date Changed Date Changed Date Changed 26 YSP 11 11 VER 1 0 INDICATOR CONTROL CARD USER MANUAL Appendix A Technical Specification Electrical Data Microprocessor Input Voltage 12 24VDC
12. iguration menus The display also gives information on the inputs as can be seen in the diagram overleaf these are position inputs message inputs speech and indicator input operation WA Unit2 Faraday Close Daventry 1 1 A Northamptonshire NN11 8RD Britain enquiries digital advanced control co uk Tel 44 0 1327 879334 INDICATOR CONTROL CARD USER MANUAL 5 Changing a Parameter The ICC has a simple intuitive graphical MMI interface to set the parameters of the indicator system The menus are configured from a set of main menus then into Sub menus where the parameters can be accessed The system can be navigated by pressing the setup button and then using the arrows to browse through the main menu to select the sub menu required Once the submenu is selected notated by the gt lt arrows on the far left and far right hand side of the display then the enter confirm button can be used to select the submenu Once in the submenu to select the desired parameter to be changed and then press the confirm button you will then enter the parameter change display Press the confirm button again and the parameter to be changed will flash The parameter now may be changed using the up and down buttons and selecting the required value Once the required value is displayed press the Enter Confirm button and the parameter will stop flashing The parameters will remain stored for at least 99 years after power removal An example of ch
13. tory Setup UP DN SETUP Board e Date And Time Management UP DN UP DN ICC Test Mode DLight Save Mode WA Unit2 Faraday Close Daventry 1 9 A Northamptonshire NN11 8RD Britain enquiries digital advanced control co uk Tel 44 0 1327 879334 5 5 INDICATOR CONTROL CARD USER MANUAL ICC Menu Structure ICC Test Mode Indicator Setup UP DN Factory Setup UP DN Board Management UP DN SETUP Position Check ICC Test Mode UP DN Message Check Speech Check No Entry Check YSP 11 11 VER 1 0 20 INDICATOR CONTROL CARD USER MANUAL 5 6 ICC Parameters The Indicator Control Card has a built in can port to act as a control interface to the serial data SF750 digital position indicators and clear view range of TFT Indicators The settings each of the parameters is described in the table below 1 1 0 0 Indicator Setup These parameters allow you to Set up the indicators 1 1 1 0 Position Input Setup 1 1 2 0 Position Input Type Lowest Level 1 1 3 0 _ 1 1 5 0 Brightness Setup Y Britain Unit2 Faraday Close Daventry Northamptonshire NN11 8RD enquiries digital advanced control co uk This parameter allows you to change what position is displayed on the indicator display This allows you to change the selected inputs from the following options DISC Line Per Floor BIN Binary INVERT BIN Inverted Binary GRAY Gray Code
14. ursts BS EN61000 4 5 1995 Surges BS EN61000 4 6 1996 Conducted Immunity 28 YSP 11 11 VER 1 0 INDICATOR CONTROL CARD USER MANUAL If you require support at any stage please do not hesitate to contact us Tel 01327 879 334 Fax 01327 877 087 E Mail enquiries digital advanced control co uk We Also Provide Free Training at Our Offices in Northamptonshire Digital Advanced kb oOontTro WA Unit2 Faraday Close Daventry 9 A Northamptonshire NN11 8RD Britain enquiries digital advanced control co uk Tel 44 0 1327 879334

Download Pdf Manuals