MEC 32 Instruction Manual - Digital Advanced Control
Contents
1. INDICATOR CONTROL CARD USER MANUAL YSP 11 11 VER 1 0 4 1 Introduction The SF750 indicator control card has been designed to act as an interface between a lift controller and the Digital Advanced Control range of dot matrix indicators and TFT LCD screens The indicator control card is a fully featured programmable unit which includes speech real time and date full opto isolation and controller area network C A N communication The unit is operated from 12 24 V A C or D C and it s a small compact unit designed to fit on DIN Rail 1 0 Standard Features A user friendly interface to allow changes to be made to the indicators and TFT displays on site Programmable inputs including line per floor binary grey code inverted binary and seven segment inputs Input monitoring via the on board liquid crystal display Real time and date from a super accurate real time clock Positive and negative common inputs as standard Self test features to simplify commissioning Controller area network C A N On board speech as standard Designed manufactured and technical support in the UK INDICATOR CONTROL CARD USER MANUAL 5 Unit2 Faraday Close Daventry Northamptonshire NN11 8RD enquiries digital advanced control co uk Tel 44 0 1327 879334 2 Indicator Control Card Layout The indicator control card consists of a main PCB board which includes p
2. UP browse adjust parameter button DN DOWN browse adjust parameter button LEFT Left browse button RIGHT Right browse button ENTER Confirm Enter button SETUP gives access to the configuration menus The display also gives information on the inputs as can be seen in the diagram overleaf these are position inputs message inputs speech and indicator input operation INDICATOR CONTROL CARD USER MANUAL YSP 11 11 VER 1 0 12 5 Changing a Parameter The ICC has a simple intuitive graphical MMI interface to set the parameters of the indicator system The menus are configured from a set of main menus then into Sub menus where the parameters can be accessed The system can be navigated by pressing the setup button and then using the arrows to browse through the main menu to select the sub menu required Once the submenu is selected notated by the gt lt arrows on the far left and far right hand side of the display then the enter confirm button can be used to select the submenu Once in the submenu to select the desired parameter to be changed and then press the confirm button you will then enter the parameter change display Press the confirm button again and the parameter to be changed will flash The parameter now may be changed using the up and down buttons and selecting the required value Once the required value is displayed press the Enter Confirm button and the parameter will stop flashing
3. M a y 1 7 2 0 1 0 Indicator Control Card User Manual INDICATOR CONTROL CARD USER MANUAL YSP 11 11 VER 1 0 2 Contents 1 Introduction 4 1 0 Standard Features 4 2 Indicator Control Card Layout 5 3 Electrical Connections 9 4 Indicator Control Card MMI Interface 10 5 Changing A Parameter 12 5 1 Example of changing the position from 1 to G 13 5 2 ICC Menu Structure Indicator Setup 17 5 3 ICC Menu Structure Factory Setup 18 5 4 ICC Menu Structure Board Management 19 5 5 ICC Menu Structure ICC Test Mode 20 5 6 ICC Parameters 21 6 Maintenance Required 25 Appendix A Electrical amp Mechanical Data 27 INDICATOR CONTROL CARD USER MANUAL 3 Unit2 Faraday Close Daventry Northamptonshire NN11 8RD enquiries digital advanced control co uk Tel 44 0 1327 879334 Revision History Date Revision Description Changed By 01 09 2011 1 0 Initial Deployment YSP
4. The parameters will remain stored for at least 99 years after power removal An example of changing the position at a floor is shown in the diagrams overleaf INDICATOR CONTROL CARD USER MANUAL 13 Unit2 Faraday Close Daventry Northamptonshire NN11 8RD enquiries digital advanced control co uk Tel 44 0 1327 879334 5 1 Example of changing the position from 1 to G INDICATOR CONTROL CARD USER MANUAL YSP 11 11 VER 1 0 14 INDICATOR CONTROL CARD USER MANUAL 15 Unit2 Faraday Close Daventry Northamptonshire NN11 8RD enquiries digital advanced control co uk Tel 44 0 1327 879334 INDICATOR CONTROL CARD USER MANUAL YSP 11 11 VER 1 0 16 INDICATOR CONTROL CARD USER MANUAL 17 Unit2 Faraday Close Daventry Northamptonshire NN11 8RD enquiries digital advanced control co uk Tel 44 0 1327 879334 5 2 ICC Menu Structure Indicator Setup INDICATOR CONTROL CARD USER MANUAL YSP 11 11 VER 1 0 18 5 3 ICC Menu Structure Factory Setup INDICATOR CONTROL CARD USER MANUAL 19 Unit2 Faraday Close Daventry Northamptonshire NN11 8RD enquiries digital advanced control co uk Tel 44 0 1327 879334 5 4 ICC Menu Structure Board Management INDICATOR CONTROL CARD USER MANUAL YSP 11 11 VER 1 0 20 5 5 ICC Menu Structure ICC Test Mode INDICATOR CONTROL CARD USER MANUAL 21 Unit2 Faraday Close D
5. 1 8RD enquiries digital advanced control co uk Tel 44 0 1327 879334 Real time clock The real time clock is provided by a super accurate real time clock with an internally temperature compensated calibrated clock to ensure the real time clock is accurate to or 3 5 ppm This Real time clock includes the minutes hours day date month and year information This automatically adjusted for months with fewer than 31 days including corrections for the leap years The clock operates in a 24 hour format and a 3 2v battery which provides backup of the time and date Should be changed every 5 years Power supply The power supply to the unit is from 12 24 V DC utilising a DC to DC switch mode power supply is reduced to 5V and 3 3V on the board the microprocessor has its own on board regulator for generating the 1 8 V and is supplied from 3 3 V The board is a 4 layer board and has separate power and ground planes internally sandwiched inside the board C A N drivers The microprocessor board has a controller area Network C A N device to implement a network for controlling the indicators The communication is at 250K bits s and uses the Peli Can V2 0B mode with 11 bit identifiers The transceiver is a MCP2551 CAN chip on the left hand side of the board LED indication of the network is provided when the LEDs are flashing brightly at a rate of 1 Hz this indicates there is no bus communication with the indicator devices If the LEDs
6. E Mail enquiries digital advanced control co uk We Also Provide Free Training at Our Offices in Northamptonshire
7. aventry Northamptonshire NN11 8RD enquiries digital advanced control co uk Tel 44 0 1327 879334 5 6 ICC Parameters The Indicator Control Card has a built in can port to act as a control interface to the serial data SF750 digital position indicators and clear view range of TFT Indicators The settings each of the parameters is described in the table below 1 0 0 0 SF750 indicator parameter Description 1 1 0 0 Indicator Setup These parameters allow you to Set up the indicators 1 1 1 0 Position Input Setup This parameter allows you to change what position is displayed on the indicator display 1 1 2 0 Position Input Type This allows you to change the selected inputs from the following options DISC Line Per Floor BIN Binary INVERT BIN Inverted Binary GRAY Gray Code SEVEN SEG Seven Segment 1 1 3 0 Lowest Level Sets the lowest level of the lift inputs 1 1 4 0 Highest Level Sets the number of floors of the Lift 1 1 5 0 Brightness Setup Set the intensity level of the indicators INDICATOR CONTROL CARD USER MANUAL YSP 11 11 VER 1 0 22 1 1 6 0 Display Zero Position Displays a base position with no inputs 1 2 0 0 Message Setup These parameters allow you to set up the messages 1 2 1 0 Message setup This parameter allows the message to be written for each message input i e When the microprocessor outputs lift overloaded the standard message of lift overloaded wil
8. eter will display the NO ENTRY Sign on the indicators when set INDICATOR CONTROL CARD USER MANUAL YSP 11 11 VER 1 0 26 6 Maintenance Required The Indicator Control Card its self is a solid state device has few user serviceable parts and requires little maintenance but the indicator control card will require the following to be done with the power off Note Electronic boards contain static sensitive devices and should not be touched unless you have the required protection Every 5 7 Years Change the Battery in the Microprocessor Date Changed Date Changed Date Changed Date Changed INDICATOR CONTROL CARD USER MANUAL 27 Unit2 Faraday Close Daventry Northamptonshire NN11 8RD enquiries digital advanced control co uk Tel 44 0 1327 879334 Appendix A Technical Specification Electrical Data Microprocessor Input Voltage 12 24VDC 10 Relay Board Input Voltage 24VDC 10 Maximum current of the Indicator Control Card 0 25A Maximum power consumption of the Indicator Control Card 2 Watts Relay board maximum current consumption 0 15A Internal Voltages 5V 3V3 and 1 8V Microprocessor Specification Microprocessor Type 32Bit RISC Microcontroller with a MIPS32 M4K core operating at 60MHz and 90MIPS Ca
9. flash INDICATOR CONTROL CARD USER MANUAL YSP 11 11 VER 1 0 8 dimly and at a much faster rate then communication with the indicator devices is successful Contrast potentiometer The contrast of the display of the microprocessor can be adjusted by the contrast pop located on the top left hand side of the microprocessor Speech Unit The indicator control card has an on board speech unit included This provides a digitised speech output with a carrier frequency of 21 6 kHz The digitised speech is filtered and then amplified using the latest D Class amplifier technology allowing for a heat sink less design compact size and clarity of sound INDICATOR CONTROL CARD USER MANUAL 9 Unit2 Faraday Close Daventry Northamptonshire NN11 8RD enquiries digital advanced control co uk Tel 44 0 1327 879334 3 Electrical Connections INDICATOR CONTROL CARD USER MANUAL YSP 11 11 VER 1 0 10 4 Indicator Control Card MMI Interface The MMI interface of the MEC32 is a Alphanumeric character LCD display which has 5 push buttons to navigate the setup menus The buttons are configured in an intuitive arrangement similar to most modern day mobile phones allowing for ease of operation INDICATOR CONTROL CARD USER MANUAL 11 Unit2 Faraday Close Daventry Northamptonshire NN11 8RD enquiries digital advanced control co uk Tel 44 0 1327 879334 The buttons are as follows UP
10. l be displayed this could be changed to lift overloaded please reduce the load The lift overloaded message which is message one will only ever be displayed on the car 1 3 0 0 Speech Setup These parameters allow you to set up the functionality of the speech module 1 3 1 0 Announce All FL This parameter is set when announcing of the floors is required as each floor is passed without a speech position trigger 1 3 2 0 Speech Volume This parameter adjusts the level of the volume from the speech module between 0 100 1 3 3 0 Quiet volume This parameter adjusts the level of the volume when the speech INDICATOR CONTROL CARD USER MANUAL 23 Unit2 Faraday Close Daventry Northamptonshire NN11 8RD enquiries digital advanced control co uk Tel 44 0 1327 879334 module is in quiet mode between 0 100 The Quiet mode selection can be adjusted in the timed event settings 1 4 0 0 Arrow setup These parameters allow you to set up the functionality of the scrolling arrows 1 4 0 0 Direction arrow type This selects the type of direction arrow to be displayed 1 5 0 0 Scroll speed setup These parameters allow you to set the scrolling speeds of the indicators 1 5 1 0 Position scroll speed This parameter selects the speed of the scrolling position 1 5 2 0 Message scroll speed This parameter selects a speed of the scrolling messages 1 5 3 0 Arrow scroll speed This parameter selects the speed
11. n Ports 1 Can ports operating at 250Kbits Sec with a maximum bus length of 200m terminated by 120 resistor Real Time Clock Super accurate real time clock with an internal temperature compensated clock frequency with a drift of 3ppm Display 4x20 STN Alphanumeric White On Blue LCD Display with LED Backlight Dimensions Dimensions 195mm x 115mm x 40mm Weight 250 grammes Inputs 12 24V DC inputs Can be switched positively and negatively draw 5mA each input INDICATOR CONTROL CARD USER MANUAL YSP 11 11 VER 1 0 28 Operational Temperatures Maximum Operating Temperature 60 C Maximum Ambient Temperature 40 C Minimum Operating Temperature 10 C EMC Compliance Emissions BS EN12015 2004 Lifts Escalators amp Passenger Conveyors BS EN55022 2006 A1 2007 Class A Emissions Standard for Information Technology Equipment Immunity BS EN12016 2004 Lifts Escalators amp Passenger Conveyors BS EN61000 4 2 1995 Electrostatic Discharge BS EN61000 4 3 2002 Radiated Immunity BS EN61000 4 4 1995 Fast Transient Bursts BS EN61000 4 5 1995 Surges BS EN61000 4 6 1996 Conducted Immunity INDICATOR CONTROL CARD USER MANUAL 29 Unit2 Faraday Close Daventry Northamptonshire NN11 8RD enquiries digital advanced control co uk Tel 44 0 1327 879334 If you require support at any stage please do not hesitate to contact us Tel 01327 879 334 Fax 01327 877 087
12. of the scrolling arrows 1 6 0 0 Hall arrow and Gong set up These parameters allow you to set the functionality of Hall arrow and gongs 1 6 1 0 Hall arrow type This parameter selects the type of hall arrow to be displayed 1 6 2 0 Hall Gong This parameter if set to yes turns INDICATOR CONTROL CARD USER MANUAL YSP 11 11 VER 1 0 24 on the hall gongs 1 6 3 0 Car Gong This parameter if set to yes turns on the car gong only 1 7 0 0 No Entry Setup 1 7 1 0 No Entry Setup This parameter sets if message input Displays the NO ENTRY Symbol 2 0 0 0 Board Management These parameter set the Board configuration Parameters 2 1 1 0 Date And Time This parameter sets the time and date of the real time clock for displaying the time on the Clear View indicators 2 1 1 0 DLight Saving This parameter sets if the day light saving is ON or OFF 2 2 0 0 ICC Test Modes These parameters set up the self test modes of the Indicator Control Card 2 2 1 0 Position Check This parameter displays the position on the position indicators automatically 2 2 2 0 Message Check This parameter displays the messages automatically on the indicators INDICATOR CONTROL CARD USER MANUAL 25 Unit2 Faraday Close Daventry Northamptonshire NN11 8RD enquiries digital advanced control co uk Tel 44 0 1327 879334 2 2 3 0 Speech Check This parameter checks the speech and speaker operation 2 2 4 0 No Entry Check This param
13. ower and input stages connections for communication and a speaker a LCD and an operator keypad There are LED s to give indication of successful communication and operation of the card Setup menus are accessed via the operator interface which is designed to be both flexible and user friendly INDICATOR CONTROL CARD USER MANUAL YSP 11 11 VER 1 0 6 Connections Description Voltage AC1 AC2 AC DC Input 12 24V CH CL Serial data C A N output SP1 SP2 Speaker output M1 Lift overloaded 12 24V M2 Lift under fire control 12 24V M3 Lift under fire alarm operation 12 24V M4 Lift on inspection control 12 24V M5 Lift out of Service 12 24V M6 Lift on Evacuation Control 12 24V M7 CUSTOM 12 24V DOI speech input doors opening 12 24V DCI speech input doors closing 12 24V PT position trigger 12 24V SX Un used 12 24V HU Hall Lantern up input 12 24V HD Hall Lantern down input 12 24V IU scrolling arrow up input 12 24V ID scrolling arrow down input 12 24V MC message common 12 24V PC position common 12 24V P1 P8 position inputs 1 to 8 12 24V LED Description LOOP Loop Led If not beating then the microprocessor has failed 3V3 Indicates the 3V3 supply is present 5V Indicates the 5V supply is present TX Can port 1 transmit LED RX Can port 1 receiver LED INDICATOR CONTROL CARD USER MANUAL 7 Unit2 Faraday Close Daventry Northamptonshire NN1
Download Pdf Manuals
Related Search
Related Contents
Quantum superloader 3 User's Manual MITIEYS DECEMBRE 2014 ジョイントスリーブ取扱説明書 manuel d`instructions et d`utilisation modèle 1100 poêle 2015 Ranger RT Brochure Télécharger Guia de Inicio Rapido Cargarlo AmpliVox VHF S1600 User's Manual KTI Networks KS-115F Series User's Manual - Hawking Technology Copyright © All rights reserved.