Home

Spin Doctor Manual - Kenton Electronics

image

Contents

1. Spin Doctor Foreword Congratulations on your purchase of a Kenton Spin Doctor Using the technology that made the Kenton Control Freak one of the most popular MIDI controllers in the world Spin Doctor offers incredible value for money and immense control over all of your MIDI devices Please take the time to read this manual thoroughly as it explains everything you will need to know in order to get the most from your purchase Because of its ability to generate any type of MIDI message including SysEx and NRPNs when used in conjunction with the PC and Mac editing software Spin Doctor allows you to unlock the full potential of any device that conforms to the MIDI standard What is Spin Doctor Spin Doctor is a MIDI hardware controller which allows you to control any piece of MIDI equipment be it a synth soft synth soundcard sequencer or anything else with a MIDI IN port The degree to which you can do this depends only on the amount of external MIDI control that particular piece of equipment has been designed to allow From the front panel you can control most common MIDI devices using standard MIDI controller messages With the hundreds of Control Freak profiles available from our website and the free software editors Spin Doctor opens up a whole new world of possibilities rd ae DAR Features 16 fully programmable rotary knobs Front panel editing of controller messages Software editor support for SysEx
2. where the virtual faders on the computer screen can be manipulated from Spin Doctor s real world control knobs Another very popular use is for controlling software synths such as the excellent Native Instruments range This removes the need for tedious adjustments by mouse and is a far more intuitive way of working What is the principle of operation of Spin Doctor Spin Doctor is a device to make editing and controlling everything from MIDI hardware to software sequencers and software synths easier than ever before Unlike many other low cost controller units Spin Doctor when used in conjunction with the editing software for PC and Macintosh has the power to support all possible MIDI messages not just the limited controllers and NRPNs found on other products in this price range In most MIDI strings used to control equipment be they SysEx messages continuous controller messages CCs or NRPNs there is usually one byte which actually specifies the new value required With System Exclusive SysEx particularly out of typically around 12 bytes often only one or two bytes need to change to give you the change in sound The rest are there to specify the manufacturer the synth model the type of message and which parameter you want to change When setting up a knob to control something most of the bytes have fixed values When it comes to the variable data bytes these can be set up to take their value from the knob With Spin
3. Doctor editing from the front panel is restricted to just controller data and we recommend the use of the PC and Macintosh editing packages to get the full benefit of the power of Spin Doctor What really sets Spin Doctor apart is the fact that it is fully compatible with the range of profiles designed for the award winning Kenton Control Freak Studio Edition and Control Freak Live You can download hundreds of presets free from our website for a wide range of popular MIDI applications both old and new Here too you will find the free software editors for Spin Doctor which allow you to fully program the unit from a PC or Macintosh Spin Doctor is also ideal as an inexpensive channel expander for existing Kenton Control Freak users The units can be linked together and profiles transferred from the Freak to Spin Doctor and vice versa making setups even more flexible Mac editor is currently in the advanced stages of development Itis not possible to transfer profiles to or from the Control Freak Original due to the different data formats used although the units may still be used in tandem Including Spin Doctor in your MIDI setup Connecting up 1 In the most basic setup where you have only a keyboard synthesiser sound module or MIDI effects processor connect the MIDI OUT of Spin Doctor to the MIDI IN of your synthesiser In the following diagram you can see a basic setup with Spin Doctor connected to the MIDI IN on a synt
4. several useful functions to the F KEY Use the DATA ENTRY knob to cycle throught the choices available When you stop moving the DATA ENTRY knob the name of the function currently selected will scroll across the screen twice then the screen will revert to butn The functions available are as follows Snapshot default Sends the current position of all 16 knobs over MIDI Reset all controllers Sends a reset all controllers message on the global MIDI channel All notes off Sends an all notes off message on the global MIDI channel GM reset Sends a General MIDI reset message XG reset Sends a Yamaha XG reset message VST Mixer select Selects the Cubase VST SX mixer to control when used in conjunction with the Kenton VST SX profiles Both the knobs and the F KEY operate as normal in this mode This assignment is not stored and will be forgotten when Spin Doctor is switched off PSnd Program Change send This mode allows you to send MIDI program change messages to your equipment Use the DATA ENTRY knob to select the required program change value in the range of 0 127 Since programs sometimes start at 1 you may need to send a value that is one lower than the program you actually wish to change to e g to change a device to program 10 select P 9 Once you have selected the program number press the F KEY to send the program change to any MIDI device The MIDI OUT indicator will light and the program chang
5. A ENTRY knob to switch between the different memory locations As each one is called up the name of the profile it contains will scroll across the screen If the location is blank then just the program number will briefly be shown followed by a short blank screen and then again the program number shown in the form PrXX where XX is the program number from 0 24 If you are using a computer and a sequencer load a song on the sequencer and start it playing Connect your Spin Doctor to your computer and assign the MIDI IN on your sequencer to come from the MIDI OUT of Spin Doctor for example if you were using a Yamaha SW1000XG sound card as your MIDI Interface then you would set the MIDI IN for your software to come from SW1000 MIDI IN and you would have the MIDI OUT of Spin Doctor connected to the SW1000XG MIDI IN port Select program 0 on Spin Doctor and move the rotary knobs If you have a 16 track MIDI song loaded up then you should be able to control the volumes of each of the tracks from Spin Doctor This you will immediately see is far easier than using a mouse to control volume levels You probably want to do more than just control the volumes of tracks so move the DATA ENTRY knob one click to the right and the screen will flash Pr 1 Program 1 which will allow you to modify as the display shows the panning control for tracks 1 16 For in depth control of software sequencers plug ins and software synths you will need to refe
6. DI file for the profile you wish to load inside your sequencer Profiles must be loaded one at a time so always start with an empty song otherwise you may end up with two or more files loaded Press the PLAY button on your sequencer and the profile will load into Spin Doctor It s as simple as that Note Spin Doctor is not compatible with the Freak Original profiles Submit your own profiles We welcome profiles submitted by our customers for the benefit of other users You can email these along with general comments and ideas to feedback kentonuk com MIDI Analyser Mode Spin Doctor also has a MIDI analyser function This feature allows you to see what types of MIDI messages are being transmitted by your equipment In this way Spin Doctor may be used as a powerful diagnostic tool if you have a problem with your MIDI set up To enter analyser mode switch the unit on whilst holding down the F KEY The display will show the software revision number of the unit until the F KEY is released at which point it will change to ntno note number Use the DATA ENTRY knob to select the type of MIDI message you want to display The data types available and their abbreviations are as follows ntno ntvL ccno ccvL chAn Prog SX n tcn StAt Note number display will change to show the note number if a note on message is received Note velocity display will change to show the note velocity if a note on message is rece
7. NRPNs and all other MIDI messages 1 multi function EDIT button 1 multi function F KEY DATA ENTRY rotary encoder knob e 4x 7 segment LED display with scrolling text MIDI IN OUT with merging Soft Thru 25 user memories Individual names for every knob and program Knobs can send any MIDI message including multiple and inverted messages software editor required for detailed editing SysEx dump of profiles to external devices Snapshot function sends all current slider positions to MIDI OUT MIDI analyser mode Rugged metal construction Hundreds of profiles already available from www kentonuk com download What are the benefits of using Spin Doctor Many pieces of MIDI gear have no front panel controls of their own whilst others possess on board controls which are frustrating and fiddly to operate Spin Doctor gives you the hands on control you need to access the various parameters on such pieces of equipment instantly and in real time The ability to tweak volumes filters envelopes and other popular effects with such ease can give a new lease of life to your existing MIDI equipment Why pay out for new synth modules when you can unlock the full potential of the ones you already own Spin Doctor is an excellent time saving device One of the most popular uses for the unit is as a control surface for sequencers such as Cubase VST SX Emagic Logic Audio and Cakewalk Pro Audio Sonar
8. and pay for carriage to and from Kenton Electronics Written by Nick Howes Anthony Barden amp John Price Kenton Electronics Brookfarm House Station Road South Wimbledon Londen 51 19 ZLF 44 0120 8544 9200 Fax 44 0 20 8544 9300 Email info kentanuk cam www kentonuk com KENTON
9. ange send ScrL Scroll speed adjustment for scrolling text MAP Map incoming profiles to the program location of your choice dMP Dump a Spin Doctor profile Edit Edit a knob to send the controller number of your choice Pressing the EDIT key at any time will show the currently selected mode PSEL Program select This is the default mode which allows you to select any one of the 25 memory locations Use the DATA ENTRY knob to change the current program number When you stop moving the DATA ENTRY knob the current program name will scroll across the screen To display the program name again press and release the EDIT button When you turn a knob the value is shown in the display and the MIDI OUT indicator lights to show that you are sending MIDI When you stop moving the knob the knob name will scroll across the screen Pressing the EDIT button will mute the MIDI output from Spin Doctor until the EDIT button is released This is useful if you want to set a knob to a new value without sending the interim values or if you want to check what a knob does If you turn a knob while the EDIT button is held down the value is shown in the display but the MIDI OUT indicator will not light as no MIDI is being sent When you stop moving the knob the knob name will scroll continuously across the screen By default the F KEY sends a snapshot of all 16 knobs in their current position Sending a snapshot will cause the MIDI indicator to flash briefl
10. e command will be sent on the global MIDI channel You can change the global MIDI channel by going to chAn in edit mode see page 11 The knobs operate as normal in this mode ScrL Scroll speed adjustment for scrolling text default 6 This mode allows you to adjust the scroll speed for the text being displayed by Spin Doctor Use the DATA ENTRY knob to change the scroll speed from 1 16 where 1 is the fastest and 16 is the slowest Press the F KEY to store your selection display will read Stor The knobs operate as normal in this mode MAP Map incoming profiles to the program location of your choice This mode allows you to specify the program location that a profile will load into All pre programmed profiles carry within them the program number for which they are destined to enable the software editors to work effectively You can override the allocated program number and make profiles load into the program location of your choice In some cases this is essential as Spin Doctor will ignore any profile with an allocated program number that is higher than 24 Initially the display will show MXX where XX is the last program selected from 0 24 You can use the DATA ENTRY knob to change this to whichever program location you wish to map to If you change the mapping location the current program will change to the same number When you have selected a program you can load a profile in the usual way While the profile is being r
11. eceived the MIDI IN indicator will light and the SysEx indicator will flash The knobs operate as normal in this mode but the F KEY will do nothing Notes 1 Spin Doctor can only use the knob slider parts of the data and will ignore any button data from Control Freak profiles Please be aware of this when loading profiles from a Control Freak into Spin Doctor or vice versa When dumps are transmitted to a Freak Studio Edition or Live Spin Doctor will transmit button data for compatibility but will transmit empty button data 2 MAP mode also works with individual knob assignments although you can only specify the program location not which knob they will load into dMP Dump a Spin Doctor profile This mode allows you to dump complete profiles into another Spin Doctor a Kenton Control Freak or a data librarian package In this way you can store your own custom presets on your computer to be loaded back into Spin Doctor as required Initially the display will show d XX where XX is the last program selected from 0 24 You can use the DATA ENTRY knob to change this to whichever program location you wish to dump from When you have selected a program press the F KEY to send the dump While the dump is being sent the display will show but the MIDI OUT and SysEx indicators will not light The display will revert to d XX when the dump has been transmitted The knobs operate as normal in this mode Edit Edit a knob to send
12. encer then you need the MIDI OUT of Spin Doctor connected to the MIDI IN of your computer and whatever you might previously have had plugged into the MIDI IN of the computer should now be plugged into the MIDI IN of Spin Doctor This is shown in the diagram below MEDIN our MIDI OUT WEDI IN MIDI OUT il 5 For connecting Spin Doctor up to a Control Freak we recommend that you connect the MIDI OUT of the Control Freak to the MIDI IN on Spin Doctor and the MIDI OUT of Spin Doctor to the MIDI IN on your computer In this way you can edit Spin Doctor from the Control Freak during your working session as well as use both devices as either independent controller units or as one unit e g for controlling 32 channels of a software mixer MIDI OUT mi OUT MICH IM 6 If you are using a keyboard that has its own internal sounds then you may want to use these in your setup too With Spin Doctor you can access these sounds quickly and easily even in a live situation One could use Spin Doctor to make a featureless digital synth as easy to control as the original analogue synths of yesteryear RAICH IM en AAAS HOA a Advanced Set Ups In more complicated setups there may be situations where MIDI Thru boxes merge boxes and switch boxes will come in handy Kenton can supply high quality versions of these together w
13. f you have any custom setups that you wish to keep you should dump these before performing the reset See page 13 for details of how to do this Downloading Profiles How do download profiles from the web and load them in We are continually adding to the hundreds of profiles already on our website These profiles are available for download free from our website www kentonuk com download From the download page of the website click on the Freak Live amp Studio Edition profiles link This will bring up a File Download window Click on Save to store the zip file on your hard drive Once you have downloaded the zip file you will need to extract it using Winzip or a similar application The profiles are saved as MIDI mid files grouped by manufacturer They can be loaded into Spin Doctor using any suitable Windows Atari Macintosh or Linux sequencer application or indeed any MIDI file format compatible hardware capable of sending SysEx data Please ensure that you set the tempo in your sequencer relatively low and turn off any MIDI processing or quantisation on the track to avoid data transfer errors You should also turn off any SysEx filters Connect the MIDI OUT of your sequencer to the MIDI IN of Spin Doctor This is the only MIDI connection required for loading profiles Don t forget that Spin Doctor needs to be in MAP mode to specify which program location the profiles will load into see page 13 for details Open the MI
14. hesiser This can just as easily be a hardware module being controlled directly from Spin Doctor MI OWT 1 ae JEU SPIN DOCTOR KEYBOARD WITH INTERNAL SOUNDS 2 In a simple setup where you typically have a controller keyboard connected to a computer which has a sound card installed you would normally have the MIDI OUT of your keyboard connected directly to the MIDI IN of your computer To include Spin Doctor in your system it should be inserted between the keyboard and the computer To do this connect the MIDI OUT of your keyboard to the MIDI IN of Spin Doctor and connect the MIDI OUT of Spin Doctor to the MIDI IN of your computer GUT _ Spin Doctor will automatically pass any MIDI it receives at its MIDI IN directly to its MIDI OUT Whenever you move any knobs or press the F KEY in specific modes on Spin Doctor this is merged with the MIDI from your keyboard and everything is sent directly to your computer 3 If you have a sound module or other synthesisers connected to the MIDI OUT of your soundcard this is not a problem as your sequencer will generally pass MIDI received at its MIDI IN to its MIDI OUT This is often known as Soft Thru This kind of connection is shown in the diagram below miD OUT MIHIN MIDI OUT u IMac THRU ou 2990098 our 4 Whatever your setup if you want to record the knob movements you make on Spin Doctor into your sequ
15. ith a full range of MIDI leads and other sundries Contact us via the details found at the back of this manual Getting Started Switching on Please connect the supplied power adapter to your Spin Doctor Kenton can and will only warranty the operation of Spin Doctor with the supplied adapter exception is the Australian market Usage of other power supplies may cause damage to Spin Doctor which will void your warranty For replacement adapters please contact Kenton When you first power up the unit the 4 x 7 segment LED display will scroll the name Spin Doctor and then default to Pr 0 Program 0 This program is pre loaded with a profile to control the MIDI volume controller 7 on MIDI channels 1 16 assigned logically to knobs 1 16 The best way to familiarise yourself with Spin Doctor is to experiment with some of the pre loaded factory profiles Spin Doctor is pre loaded with 6 useful profiles to get you started These are Program 0 Volumes on MIDI channels 1 16 Program 1 Pans on MIDI channels 1 16 Program 2 Controllers 1 16 all on the global MIDI channel default 1 Program 3 Controllers 17 32 all on the global MIDI channel default 1 Program 4 Controllers 33 48 all on the global MIDI channel default 1 Program 5 Controllers 49 64 all on the global MIDI channel default 1 Programs 6 to 24 are left blank for the user to program or load pre programmed profiles as required Use the DAT
16. ived Controller number display will change to show the controller number if a controller message is received Pbnd if pitchbend is received or Aft if aftertouch is received Controller value display will change to show the data value if a controller pitchbend or aftertouch message is received MIDI channel display will change to show the MIDI channel of any message received Program change display will change to show the program number in the range of 1 128 if a program change message is received SysEx display will change to SX if System Exclusive is received Timing clock MIDI clock display will change to te Y if MIDI clock is received Clock status display will change to StoP if a clock stop command is received Strt if a clock start command is received or cont if a clock continue command is received In every case the display will only change if the relevant message is received Overview of the MIDI message format To make it easier to understand MIDI data bytes are usually represented in either decimal base 10 or hexadecimal base 16 numbers On Spin Doctor data are always shown in decimal format This quick guide is to help and explain the data types and message types for MIDI The MIDI standard uses 0 255 in the following way 00 7F 0 127 variable for data Channel Commands Data 1 0 127 Data 2 0 127 80 8F Note on channels 1 16 Note number Velocity 90 9F Note off channels 1 16 No
17. r to the relevant user manuals for information about configuring the software to respond to external MIDI control In many cases we will have already created profiles which can be downloaded from our website www kentonuk com Editing Spin Doctor We have demonstrated how easy it is to connect and immediately start to use Spin Doctor in your MIDI environment The profiles can be used not only with software applications but also with any MIDI hardware device so feel free to connect and experiment with your existing MIDI hardware using some of the controller based presets that are to be found in Spin Doctor Front panel editing modes All of the editing modes on Spin Doctor can be accessed by pressing the EDIT button to the right of knob 8 Depressing this and releasing it after first powering up will display PSEL Program Select then scroll the name of the profile in the program currently selected across the screen before reverting back to a static display of the program number e g Pr 0 To start editing Spin Doctor simply hold down the EDIT button whilst turning the DATA ENTRY knob When you have reached the required mode release the EDIT button and use the DATA ENTRY knob to change the value of the selected parameter The editing modes available and their abbreviations are as follows PSEL Program Select default chAn Global MIDI channel select butn Selects what function the F KEY will perform in the main level PSnd Program Ch
18. te number Velocity AO AF Poly after touch channels 1 16 Note number Aft Amount BO BF Controllers channels 1 16 Controller number Controller value CO CF Programs channels 1 16 Program number DO DF Mono after touch channels 1 16 After touch amount EF Pitch bend channels 1 16 LSB MSB System Common Commands FO Begin System Exclusive Company ID data data F7 F1 MIDI time code quarter frame Type Value F2 Song position pointer LSB MSB F3 Song select Song number F4 Undefined F5 Undefined F6 Tune request F7 End System Exclusive System Real time Commands F8 Timing clock F9 Undefined FA Clock start FB Clock continue FC Clock stop FD Undefined FE Active sensing FF System reset Specifications User interface Controls 16 x linear response rotary control potentiometer knobs 1 x F KEY push button 1 x EDIT push button DATA ENTRY rotary encoder knob Power switch Display LED 4 x 7 segment Connections Inputs DC Power socket 2 1mm centre positive MIDI IN 5 pin DIN type Outputs MIDI OUT 5 pin DIN type Accessories Operating manual Mains power adapter UK EU USA Physical data Dimensions 390 mm x 120mm x 58mm Weight 1 5Kg boxed with PSU Power Requirement 9V d c 250mA Warranty Spin Doctor comes with a 12 month back to base warranty from purchase date Customers must arrange
19. the controller number of your choice This mode allows you to assign any MIDI continuous controller number 0 127 to any knob in any program In this way you can control any piece of MIDI equipment that responds to controller messages You will need to use PSEL mode to select the program to edit see page 10 Initially the display will show EdXX where XX is the last knob moved from 1 16 If you want to edit a different knob simply turn the DATA ENTRY knob to select a different knob number Then turn the corresponding knob to select the controller number you wish to assign Knobs other than the one selected will do nothing When the display is showing the controller number you wish to assign press the F KEY to store your selection The display will then revert showing EdXX Neither the knobs nor the F KEY will send any MIDI data in this mode Factory Reset If you find at any stage that you are encountering problems with Spin Doctor then it may be worth trying the factory reset option This will return the unit to the same operational state as when it was first supplied to you To reset Spin Doctor to factory defaults switch the unit on whilst holding down both the EDIT button and the F KEY The display will show before scrolling the name Spin Doctor and then defaulting to Pr 0 Program 0 Important This operation will erase all profiles except for those pre loaded at the factory these are listed on page 8 I
20. y indicating MIDI OUT activity You can change the function of the F KEY by going to butn in edit mode see page 12 If a blank program is selected only the program number will be displayed Ifan unassigned knob is moved only the value will be displayed chAn Global MIDI channel select This mode allows you to change the default MIDI channel that Spin Doctor sends on The display will show the current global MIDI channel which by default is channel 1 shown as ch 1 To adjust the MIDI channel simply rotate the DATA ENTRY knob either clockwise or anti clockwise and you will see the display change from ch 1 through to ch16 denoting MIDI channels 1 16 This is useful when controlling a synth or other device on a specific MIDI channel An example of this could be a synth or drum machine in your studio which only works in Poly mode and is set to MIDI channel 10 Setting the global channel to 10 would allow you to send specific edits to that device only The global MIDI channel can be overridden by MIDI channels defined at either a program or individual knob level Some of our website profiles have been set up in this way but you cannot assign separate MIDI channels to different knobs from the front panel of Spin Doctor To do this you will need the software editors Both the knobs and the F KEY operate as normal in this mode butn Selects what function the F KEY will perform in the main level This mode allows you to assign one of

Download Pdf Manuals

image

Related Search

Related Contents

電磁弁  Traffic User Manual - Terias Consulting Ltd  MANUAL DE INSTRUÇÕES  Perel WAF18M2 vacuum cleaner  

Copyright © All rights reserved.
Failed to retrieve file