1. e Do not attempt to dispose of batteries by burning them This could cause battery explosion e Do not open or destroy batteries Escaping electrolyte can cause injury to the skin and eyes It may be toxic e Please replace the fuse only by a fuse of the same type and of the same amperage in order to avoid fire hazards e Do not dismantle the UPS system Page 4 V2 8 Emerson Network Power Liebert PSA itON Installation and User Manual Product Introduction 2 Product Introduction O i iy This UPS is specially designed for Personal Computer with multi functions Its light weight compact design perfect fits to the limited working environment The line of UPS is equipped with boost and buck AVR to stabilize input voltage range It is also built in with DC start function This function enables the UPS to be started up without AC power supplied Although it s a small UPS it s equipped with Smart RS 232 Communication Port to offer users more benefits The download software helps users monitor UPS inside status The main features of the UPS are listed below e Microprocessor control guarantees high reliability e Equipped with Boost and Buck AVR to stabilize the input voltage e DC Start Function e Built in RS 232 Communication Port e Free Software bundled Please check UPS Monitoring Software for detail information e Green Power Function for energy saving e Auto restart while AC recovers e Compact size Light weight e Provides
2. 7 Turn On Off To turn on the UPS just simply press power switch Please do so gently to extend the life of the power switch 4 8 DC Start Function DC Start Function allows the UPS to start up when AC utility power is not available and the battery is fully charged Just simply press the power switch to turn on the UPS 4 9 Green Power Function All these Series are equipped with Green Power Function If no load connects to the UPS it will automatically shut down in 45 seconds for energy saving while power failure The UPS will restart while AC recovers This feature is only applicable with itON 600 Page 9 V2 8 Emerson Network Power Liebert PSA itON Installation and User Manual Software 5 Software Po 000 Free UPS Monitoring Software The UPS monitoring software provides user friendly interface to monitor and control your UPS This unique software provides safe auto shutdown for multi computer systems during a power failure With this software users can monitor and control any UPS on the same LAN no matter how far from the UPSs Features e Saves files before shutdown occurs e Scheduled system shutdown e Graphic display of UPS status e Warning notification via E mail e User friendly interface e Multi language versions System Log UPS Tools Mondor Erfimace Langer Hely a ciel e com Vong zog y a a 40 Hz Ej pi Mar Vall m0 CP vay iin Youll cli T Ls Eee AC LINE Nine OM LINE F
3. Modem and Phone line Surge Protection e Provide AC Overload Protection Page 5 V2 8 Emerson Network Power Liebert PSA itON Installation and User Manual System Description 3 System Description E Front panel 1 Power Switch LED AC Mode Green LED on Battery Mode Green LED flashing Back Panel 1 Output receptacles 2 AC Input 3 Modem Phone line Surge Protection 4 Communication Port 4 itON 600 itON 1000 itON 600 India Version Page 6 V2 8 Emerson Network Power Liebert PSA itON Installation and User Manual Installation 4 Installation i i_O Installing the UPS is as easy as following the steps shown Be aware that the power Switch must be kept in the ON position otherwise the UPS will be disabled and your equipment will not be protected during a power failure 4 1 Inspection Remove the UPS from its package and inspect it for damage that may have occurred during shipping If any damage is discovered re pack the unit and return it to the place of purchase i b Moe 4 2 Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an environment where the ambient temperature or humidity is high 4 3 Charging This unit is shipped from the factory with its internal ba
4. the building wiring socket outlet shockproof socket outlet Please use only VDE tested CE marked power cables to connect the loads to the UPS system The UPS must be serviced by an authorized representative of Emerson Network Power Failure to do so could result in personnel safety risk equipment malfunction and invalidation of warranty The Liebert PSA itON has been designed for Commercial Industrial use only and is not recommended for use in life support applications In the event of Emergency press OFF button and disconnect the power cord from AC Power supply to properly disable the UPS Do not plug UPS input to its own output Do not attach power strip or surge suppressor to the UPS Page 3 V2 8 Emerson Network Power Liebert PSA itON Installation and User Manual Safety Instructions Operation e Do not disconnect the mains cable on the UPS system or the building wiring socket outlet shockproof socket outlet during operations since this would cancel the protective earthing of the UPS system and of all connected loads e The UPS system features its own internal current source batteries The UPS output sockets or output terminals block may be electrically lived even if the UPS system is not connected to the building wiring socket outlet e In order to fully disconnect the UPS system first press the Standby switch then disconnect the mains lead e Ensure that no fluids or other foreign objects can enter the UPS system Maintena
5. Liebert PSA itON UPS User Manual Version V2 8 Revision date November 14 2005 Emerson Network Power provides customers with technical support Users may contact the nearest Emerson local sales office or service center While every precaution has been taken to ensure accuracy and completeness in this manual Emerson Network Power assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions Emerson Network Power pursues a policy of continuous product development and reserves the right to change the equipment design without notice Copyright 2005 by Emerson Network Power All rights reserved The contents in this document are subject to change without notice Page 1 V2 8 Emerson Network Power Liebert PSA itON Contents Safety Instructions 1 2 Page 2 Product Introduction System Description Installation Software Troubleshooting Technical data V2 8 Installation and User Manual Table of Contents 7 9 10 11 12 Emerson Network Power Liebert PSA itON Installation and User Manual AN Safety Instructions Safety Instructions As dangerous voltages are present within the UPS only an Emerson technician or an Emerson authorized technician is permitted to open it Failure to observe this could result in electric shock risk and invalidation of any implied warranty Transport Please transport the UPS system onl
6. hnical Data Liebert PSA itON PS600 TN PS1000 TN 600VA 1000VA CAPACITY Voltage Regulation Frequency Regulation Overload 110 for 5 minutes as Mains 110 for 5 minutes as Mains Overload mode mode SAREI TYPES 12V 7AH 1Pc 12V 7AH 2 Pcs BATTERY CRUD IME AS RED liras 30 min typical with 1 PC the loads 8 hours to 90 after complete 8 hours to 90 after complete discharge discharge Typical 4 8 ms Green Lights Up The 1st green lighting up the 2nd to 5th green lighting up indicates load capacit Green Flashes The 1st green flashing the 2nd Sle ATES to 5th green gradually lighting indicates batteries capabilit Faut Red Lightingup AUDIBLE ALARM PROTECTION Full Protection Discharge overcharge and Discharge overcharge and overload protection overload protection Dimension m m PHYSICAL DxWxH 330 x 100 x 140 369x141x181 Net Weight 13 5 kg Operate Eronen 0 40 C 0 90 relative humidity 0 40 C 0 90 relative humidity ENVIRONMENT p g non condensing non condensino Less than 40 db Less than 40 db Support Windows Support Windows Ee pas 95 98 NT 2000 XP and Linux 95 98 NT 2000 XP and Linux For additional information on backup please contact your local Emerson Network Power representative Z z 3 o 4 D Recharge Time RANSFER TIME 4 8 ms S U Green Lights up INDICATOR Backup Mode Typical __ AC Mode 4 O 5 7 C pe ur Page 1 2 V2 8 Emerson Network Power
7. nce servicing and faults e The UPS system operates with hazardous voltages Repairs may be carried out only by qualified maintenance personnel e Caution risk of electric shock Even after the unit is disconnected from the mains power supply building wiring socket outlet components inside the UPS system are still connected to the battery and are still electrically live and dangerous e Before carrying out any kind of servicing and or maintenance disconnect the batteries and verify that no current is present and no hazardous voltage exist in the terminals of high capability Capacitor such as BUS capacitors e Only persons who are familiar with batteries and with the required precautionary measures may replace batteries and supervise operations Unauthorised persons must be kept well away from the batteries e Caution risk of electric shock The battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals and the ground Before touching please verify that no voltage is present e Batteries may cause electric shock and have a high short circuit current Please take the precautionary measures specified below and any other measures necessary when working with batteries remove wristwatches rings and other metal objects use only tools with insulated grips and handles e Do not short circuit battery terminals e When changing batteries install the same number and same type of batteries
8. ohage ai Y Com Peat mm BATTERY Bie wo V Temp mo Ct Nt Capacity Wooo SMA 008 135335 Agent Stiat a Installation procedure 1 Insert the CD into CD ROM 2 Connect the software cable 3 Follow the on screen instructions to install the software When your computer restarts the software will appear as a green plug icon located in the system tray near the clock Page 10 V2 8 Emerson Network Power Liebert PSA itON Installation and User Manual Trouble Shooting 6 Trouble Shooting No LED display 1 Missing battery 1 Charge battery on the front panel up to 4 hours 2 battery defect 2 Replace with the same type of batter Alarm buzzer Overload of the UPS Verify that the load beeps matches the UPS continuously capability specified in when AC supply the specs is normal When power 1 Remove some failure back up UPS non critical load time is reduced 2 Battery voltage is too low for 4 hours or more 3 Battery defect due 3 Replace with the to high temperature same type of operation battery environment or improper operation of the batter Mains normal but 1 Breaker is flicked on 1 Reset the Breaker LED is flashing 2 Power cord is loose power cord proper If any abnormal situations occur that are not listed above please call the authorized Emerson Network Power service engineers immediately Page 1 1 V2 8 Emerson Network Power Liebert PSA itON Installation and User Manual 6 Tec
9. ttery fully charged however some charge may be lost during shipping and the battery should be recharged prior to use Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 8 hours i amp hours amp hours itON 600 itON 1000 ION 600 India Version Page 7 V2 8 Emerson Network Power Liebert PSA itON Installation and User Manual Installation 4 4 Computer Connection Connect one computer related device into each of the power receptacles supplied on the back of the UPS COMPUTER COMPUTER COMPUTER Taal UPS eae T el El re Ge eS i p Fal aa by 9 i l a iz GUA j T a e al canal Soap ig Samia Lal wE lg 5 B itON 600 itON 1000 itON 600 India Version 4 5 Modem Phone line Connection Plug incoming internet line into the In socket at the back of the UPS Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS Plug the other end of the modem input socket as shown below itON 600 itON 1000 itON 600 India Version 4 6 Serial cable Connection To allow for unattended system shutdown for your operating system connect the serial cable as per diagram below COMPUTER COMPUTER COMPUTER itON 600 itON 1000 itON 600 India Version Page 8 V2 8 Emerson Network Power Liebert PSA itON Installation and User Manual Installation 4
10. y in the original packaging to protect against shock and impact Set up Condensation may occur if the UPS system is moved directly from a cold to a warm environment The UPS system must be absolutely dry before being installed Please allow an acclimatization time of at least two hours Do not install the UPS system near water or in damp environments Do not install the UPS system where it would be exposed to direct sunlight or near heat source Do not block off ventilation openings in the UPS system s housing Installation This manual contains information concerning the installation and operation of the Emerson Network Power Liebert PSA itON Uninterruptible Power System UPS All relevant parts of the manual should be read prior to commencing the installation Do not connect appliances or equipment e g laser printer to the output socket which would overload the UPS system Place cables in such a way that no one can step on or trip over them Do not connect domestic appliances such as hair dryers to UPS output sockets Connect the UPS system only to an earthed shockproof socket outlet Connection to any type of receptacle other than two pole three wire grounded receptacle may result in shock hazard The building wiring socket outlet shockproof socket outlet must be easily accessible and close to the UPS system Please use only VDE tested CE marked mains cable e g the mains cable of your computer to connect the UPS system to
Download Pdf Manuals
Related Search
Related Contents
La Boîte à bisous 特許出願中世界初 自動車用シートカバー兼水難事故避難装着具 producto: algicida especial piscinas cubiertas M68HC12B32EVB Evaluation Board 綺麗な写真印画紙・特厚 OPERATORS MANUAL - Landis International Inc. AL20081124 Blue Rhino 82300 Patio Heater User Manual W I C H T I G E R H I N W E I S ! ! ! W I C H brennenstuhl Manual de instruçőes Copyright © All rights reserved.