Home
datasheet: pdf
Contents
1. Notice that the Agilent 2000 X Series allows you to see more of your signals and captures the infrequent glitch that you are unable to see on other oscilloscopes in this class Deeper memory for longer time capture Agilent Aequaition With up to 100 kpts of memory you get 40X more than Steet other scopes in this class enabling you to capture long Th a eam non repeating signals while maintaining a high sample a a rate then quickly zoom in on areas of interest Deep memory lets the scope maintain a high sample rate over longer time spans How does Agilent do that Agilent designed MegaZoom IV custom ASIC technology combines the capabilities of an oscilloscope logic analyzer and WaveGen built in function generator in a compact form factor at an affordable price 4 generation WegaZoom technology enables the industry s fastest waveform update rate with responsive deep memory acquisitions Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Do more with the power of 4 instruments in 1 Best in class oscilloscope r a Fae E dpi i The InfiniiVision 2000 X Series features the deepest memory in its class with 100 kpts of Agilent s patented MegaZoom INV technology that is always enabled and always responsive providing the industry s fastest update rate at up to 50 000 waveforms per second with no compromise if you turn on measurements or add digital channels In addition t
2. falling alternate either Conventional level driven trigger e Pulse width or glitch Trigger on a pulse width less than greater than or within a time range with a selectable time limit ranging from 17 ns to 10 s e Pattern trigger on a logical AND combination of the channels Each channel can have a value of zero one don t care X or a rising or falling edge one channel only e Video Trigger on all lines or individual lines odd even or all fields from composite video or broadcast standards NTSC PAL PAL M SECAM Trigger coupling Coupling selections AC DC noise reject LF reject and HF reject Trigger source Each analog channel each digital channel MSO models or DSOX2MSO upgrade Ext WaveGen line Trigger sensitivity internal lt 10 mV div greater of 1 div or 5 mV 10 mV div 0 6 div Trigger sensitivity external 200 mV DC to 100 MHz 350 mV 100 MHz 200 MHz Types Amplitude time frequency FFT manual tracking binary HEX Measurements AT 1 AT AV X 1 AX AY Phase and Ratio Cursors e Single cursor accuracy DC vertical gain accuracy DC vertical offset accuracy 0 25 full scale e Dual cursor accuracy DC vertical gain accuracy 0 5 full scale Automatic waveforms measurements Voltage Snapshot all maximum minimum peak to peak top base amplitude overshoot preshoot average N cycles average full screen DC RMS N cycles DC RMS full screen AC RMS N cycles Ti
3. for the same budget Performance characteristics DS0X2000 Series MS0X2000 Series mixed signal oscilloscope digital signal oscilloscope 2002A 2004A 2012A 2014A 2022A 2024A 2002A 2004A 2012A 2014A 2022A 2024A Characteristic Analog Bandwidth 3 dB Bandwidth upgrade Channels Maximum sample rate Maximum memory depth record length Display Waveform update rate External trigger input Vertical resolution Horizontal resolution Vertical sensitivity range DC vertical accuracy DC vertical gain accuracy DC vertical offset accuracy Vertical zoom Maximum input voltage Position range offset Bandwidth limit Input coupling Input impedance Time base range Time base accuracy A Time accuracy using cursors Dynamic range Horizontal zoom modes 70 MHz 100 MHz 200 MHz 70 MHz 100 MHz 200 MHz YES YES NO YES YES NO f 4 2 4 2 4 2 4 Z 4 2 4 2 GSa s half channel interleaved 1 GSa s per channel 100 kpts half channel 50 kpts per channel 8 5 inch WVGA with 64 levels of intensity grading 50 000 waveforms s Included on all models 8 bits 2 5 ps 1 mV div to 5 V div DC vertical gain accuracy DC vertical offset accuracy 0 25 full scale 3 full scale gt 10 mV div 4 full scale lt 10 mV div 0 1div 2mV 1 of offset setting Ability to scale and position a live or stopped waveform vertically When the acquisition is stopped turning t
4. play stop rewind with MegaZoom V s setting the vertical and fast forward instant response and horizontal and trigger _throughwaveforms s optimum resolution lt r controls for the Horizontal 0 Run best display while Stop optinizirig memory Agilent AW Auto Scale Acquisition Normal Trager ann RA asc ae aaa Dedicated 25 MSa s Pushfor60 ff Force 4 keys for quick Channels access to digital Channels Juick summary math lisplay of yiunctions sample rate ee and hannel CL T G a S reference settings and Vertical _ waveforms neasurements All front a pe knobs are pushable Push to Zoro Demo and pr ame Integrated training s digital signals 3 voltmeter Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Configuring your InfiniiVision X Series oscilloscope Step 1 Choose your bandwidth and channel count InfiniiVision 2000 X Series scopes DS0X2002A DS0X2004A DSOX2012A DS0X2014A DS0X2022A DS0X2024A MS0X2002A MS0X2004A MSOX2012A MS0X2014A MS0X2022A MSOX2024A Bandwidth upgradable 70 MHz 100 MHz 200 MHz Analog channels 2 4 2 4 2 4 Digital channels MSO 8 integrated digital channels optional 1 See pages 20 21 for more detailed information on upgradability Step 2 Tailor your scope with measurement applications to save time and mon
5. 1000 4 4 EN 61000 4 4 IEC 61000 4 5 EN 61000 4 5 IEC 61000 4 6 EN 61000 4 6 IEC 61000 4 11 EN 61000 4 11 Canada ICES 001 2004 Australia New Zealand AS NZS Safety UL61010 1 2nd edition CAN CSA22 2 No 61010 1 04 Denotes warranted specifications all others are typical Specifications are valid after a 30 minute warm up period and from 10 C firmware calibration temperature 19 Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Performance characteristics WaveGen built in function generator Waveforms Sine Square wave pulse Ramp triangle wave Noise Frequency Amplitude DC offset Trigger output Sine square pulse triangle ramp noise DC Frequency range 0 1 Hz to 20 MHz Amplitude flatness 0 5 dB relative to 1 kHz Harmonic distortion 40 dBc Spurious non harmonics 40 dBc Total harmonic distortion 1 SNR 50 ohm load 500 MHz BW 40 dB Vpp 0 1 V 30 dB Vpp lt 0 1 V Frequency range 0 1 Hz to 10 MHz Duty cycle 20 to 80 Duty cycle resolution Larger of 1 or 10 ns Pulse width 20 ns minimum Pulse width resolution 10 ns or 5 digits whichever is larger Rise fall time 18 ns 10 to 90 Overshoot lt 2 Asymmetry at 50 DC 1 5 ns Jitter TIE RMS 500 ps Frequency range 0 1 Hz to 100 kHz Linearity 1 Variable symmetry 0 to 100 Symmetry resolution 1 Bandwidth 20 MHz typical Sine wave and ramp
6. 3 year warranty and an instru ment reliability you ve come to expect from the leader in test and measurement equipment Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Designed with manufacturing in mind Stretch a limited budget Protect your investment with the 2000 X Series If you need more bandwidth up to 200 MHz or measurement applications like mask testing in the future you can easily add them all when you need them Get your technicians to quickly put the scope to work Intuitive localized front panel design and pushable knobs for quick access to commonly used oscilloscope functions allow technicians to spend more time testing and less time learning where the menus are on the oscilloscope Enable your technicians to answer their own questions with the localized built in help system that provides quick access by simply pressing and holding any button Get a long scope life and keep repair costs to a minimum with a standard 3 year warranty and a 2 year calibration interval you get the instrument reliability you ve come to expect from the leader in test and measurement equipment Faster low escape test throughput With the fastest architecture in its class featuring up to 50 000 waveforms sec you will capture more of those elu sive problems you worry about and ensure they don t ship to customers With the mask limit testing measurement application you can quickly test up to 50 000
7. Hz Recommended Recommended N2790A 100 MHz with AutoProbe Incompatible Recommended N2792A 200 MHz Recommended Recommended N2793A 800 MHz Recommended Recommended Single ended active probes N2795A 1 GHz with AutoProbe Incompatible Recommended N2796A 2 GHz with AutoProbe Incompatible Recommended 1156A 1 5 GHz with AutoProbe Incompatible Recommended 1144A 800 MHz use with 1142A Incompatible Recommended 1145A 750 MHz use with 1142A Incompatible Recommended MSO logic probes 01650 61607 16 channel Incompatible N6459 60001 8 channel MSO cable Recommended Compatible included in 2000 X Series MSOs N6450 60001 16 channel MSO cable Incompatible Recommended included in 3000 X Series MSOs Current probes 1146A 100 kHz Recommended Recommended N2780A 2 MHz use with N2779A Recommended Recommended N2781A 10 MHz use with N2779A Recommended Recommended N2782A 50 MHz use with N2779A Recommended Recommended N2783A 100 MHz use with N2779A Recommended Recommended 1147A 50 MHz with AutoProbe Incompatible Recommended N2893A 100 MHz with AutoProbe Incompatible Recommended 1 The 2000 X Series does not support AutoProbe interface active probes 23 Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget License only bandwidth upgrades and measurement applications certificate Stick On label sheet Agilent sales partner USB drive ge A license file Bandwidth upgrade models 2000 X Series D
8. I O libraries to communicate It provides advanced FFT frequency domain analysis at a cost effective price as well as spectrum and spectrogram analysis with an intuitive user interface that RF engineers are familiar with Tools include Spectrum Measurements e Power dBm vs frequency e Horizontal x axis Specify center frequency and frequency span or start and stop frequencies e Vertical y axis Specify reference level dBm and scale dB div e Settable resolution bandwidth e Flat top Guassian or Hanning windows applied to the time domain data for the FFT analysis e Marker to peak amplitude and marker to center frequency e Marker peak search can be enabled for time varying signals e Multiple marker with delta X and delta Y readouts Acquisition and Display Modes e Free Run continuous Triggered Stop Single Preset Triggered mode specify trigger power level dBm single or continous sweep e Enable disable y axis label e Enable disable main trace display e Max hold display mode e Gated Measurements e Multiple viewing options Spectrogram waterfall 3D e Changeable scaling settings on main window e Local language support e Multiple oscilloscopes can be configured to allow user to rapidly switch between multiple instruments Arbitrary Waveform Generator Source Control e 20 MHz sine wave e 10 MHz square wave e Pulsed waveform e WaveGen source settings can be altered while ASV is running for int
9. InfintiVision 2000 X Series e Oscilloscopes c 0 ee Data Sheet 2011 FINALIST INNOVATION AWARD r 2011 Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Anticipate __Accelerate __Achieve oe Agilent Technologies Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Breakthrough technology for budget conscious customers Agilent Technologies is the fastest growing scope vendor your existing budgets Whether you are looking for a basic in the market for good reason we deploy our investments entry level oscilloscope or a more sophisticated model to in technology to solve your measurement problems get your job done you want the most you can get for your This commitment to superior technology brings you the money The full line of InfiniiVision X Series oscilloscopes InfiniiVision X Series oscilloscopes engineered to deliver 30 models ensure that you get exactly what you need value functionality and flexibility at prices that fit into today with room to grow in the future Overview of the Agilent InfiniiVision X Series oscilloscopes InfiniiVision 2000 X Series InfiniiVision 3000 X Series Analog channels 2 and 4 analog channels Digital timing channels 8 on MSO models or with 16 on MSO models or with DSOX2MSO upgrade DSOX3MSO for 500MHz models and below and DSOXPERFMSO for 1 GHz models upgrade Bandwidth upgradable 70 100 200 MH
10. SOX2BW12 70 MHz to 100 MHz 2 ch License only DSOX2BW14 70 MHz to 100 MHz 4 ch License only DSOX2BW22 100 MHz to 200 MHz 2 ch License only DSOX2BW24 100 MHz to 200 MHz 4 ch License only Measurement applications DSOX2WAVEGEN WaveGen built in function generator DSOXDVM Integrated digital voltmeter DSOXEDK Educator s kit DSOX2MASK Mask testing DSOX2SGM Segmented memory DSOX2MSO Upgrade to 8 digital timing channels m e 24 Agilent software licensing website Email containing attached licensed file a Bo Process description 1 Place order for a license only bandwidth upgrade or measurement appliction product to an Agilent sales partner If multiple bandwidth upgrade steps are needed order all the corresponding upgrade products required to get from current bandwidth to desired bandwidth In the case where the new bandwidth requires higher bandwidth passive probes they are included with the upgrade For the DSOX2BW22 and DSOX2BW24 the N2863B 10 1 300 MHz passive probes 1 per channel will be sent with the upgrade Receive a paper or electronic pdf Entitlement Certificate document for any of the orderable measurement applications For bandwidth upgrades only you receive a stick on label document indicating upgraded bandwidth specification Use Entitlement Certificate or electronic pdf document containing instructions and certificate number needed to generate a license file for a p
11. accuracy o 130 ppm frequency lt 10 kHz 50 ppm frequency gt 10 kHz Square wave and pulse accuracy o 50 frequency 200 ppm frequency lt 25 kHz 50 ppm frequency 25 kHz Resolution 0 1 Hz or 4 digits whichever is larger Range o 20 mVpp to 5 Vpp into Hi Z o 10 mVpp to 2 5 Vpp into 50 ohms Resolution 100 uV or 3 digits whichever is larger Accuracy 2 frequency 1 kHz Range o 2 5 V into Hi Z o 1 25 V into 50 ohms Resolution 100 pV or 3 digits whichever is larger Accuracy 1 5 of offset setting 1 5 of amplitude 1 mV Trigger output available on Trig out BNC 20 Integrated Digital Voltmeter Functions ACrms DC DCrms Frequency Resolution ACV DCV 3 digits Frequency 5 5 digits Measuring rate 100 times second Autoranging Automatic adjustment of vertical amplification to maximize the dynamic range of measurements Range meter Graphical display of most recent measurement plus extrema over the previous 3 seconds Measurement Range Frequency Range Vertical Range Vertical Accuracy ACRms 20 Hz 100KHz 100 MHz to 500 MHz 1 mV div to 5 V DC vertical gain accuracy 0 5 full scale DCRms 20 Hz 100KHz div 1 MQ and 50 Ohm DC vertical gain accuracy DC vertical offset 1 GHz model 1 mV div to 5 V div 1 MD 1mV div to 1V div 50 Ohm ee ee ee DC NA DC vertical gain accuracy DC vertical offset accuracy 0 25 full scale accuracy 0 25 full scale Fr
12. articular 2000 or 3000 X Series oscilloscope model number and serial number unit Receive the licensed file and installation instructions via email Copy license file lic extension from email to a USB drive and follow instructions in email to install the purchased bandwidth upgrade or measurement application on the oscilloscope For bandwidth upgrades only attach bandwidth upgraded stick on labels to front and rear panels of the oscilloscope Model number and serial number of the oscilloscope do not change Agilent Technologies Oscilloscopes Multiple form factors from 20 MHz to gt 90 GHz Industry leading specs Powerful applications 25 www agilent com www agilent com find 2000X Series For more information on Agilent Technologies products applications or services please contact your local Agilent office The complete list is available at Bey Agilent Email Updates www agilent com find emailupdates Get the latest information on the ae www agilent com find contactus products and applications you select y Americas AMi Canada 877 894 4414 KARNIG Brazil 11 4197 3600 www axiestandard org Mexico 01800 5064 800 AdvancedTCA Extensions for Instrumentation and Test AXle is United States 800 829 4444 an open standard that extends the Asia Pacific AdvancedTCA for general purpose Australia 1 800 629 485 and semiconductor test Agilent China 800 810 0189 is a founding member of t
13. ble in 11 languages Choose from English Japanese simplified Chinese traditional Chinese Korean German French Spanish Russian Portuguese and Italian During operation access the built in help system just by pressing and hold ing any button Probe solutions Get the most out of your 2000 X Series scope by using the right probes and accessories for your application Agilent offers a complete family of innovative probes and accessories for the InfiniiVision 2000 X Series scopes For the most up to date and complete information about Agilent s probes and accessories please visit our Web site at www agilent com tind scope_probes Autoscale Quickly display any active signals and automatically set the vertical horizontal and trigger controls for optimal viewing with the press of the autoscale button This feature can be disabled or enabled for the education environment i Agilent fp Anquiction E E a Agilent Run Stop en Run Control Auto Scale Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Other productivity tools OCL and LXI Compatibility Oja Built in USB host one front one back and USB device AO SEE ports make PC connectivity easy Operate the scope from mo your PC and save and recall stored waveforms as well as a az set up files via LAN An optional LAN VGA module gives DERE you network connectivity an
14. d complete LXI class C support di 0 as well as the ability to connect to an external monitor An omen a ui AN optional GPIB module is also available Only one module ff may be used at a time Intuilink toolbars and Data Capture gives you a quick way to move screen shots and data into Microsoft Word and Excel These toolbars can be installed from www agilent com find intuilink View Scope enables simple and free time correlated measurements between a 2000 X Series oscilloscope and an Agilent 16900 16800 1690 or 1680 Series logic analyzer Virtual Front Panel a pared am eee AY VK ne Pd Use the VNC viewer via your internet browser to remotely control your oscilloscope from your computers web browser The virtual front panel looks and acts as the real front panel on the oscilloscope with the same associated keys and knobs Use this capability in cases where remote training and learning of the oscilloscope are required This instrument is fully LXI complaint with the LAN VGA connection module Secure environment mode The SEC Secure Environment Mode comes standard with all models and provides the highest level of security by ensuring that internal non volatile memory is clear of all setup and trace settings This option stores setups and traces to internal volatile memory only and volatile memory is cleared during the power off cycle of the instrument This procedure ensures that all setup and trace settings ar
15. e removed from memory Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Designed with education in mind Quickly and easily set up or upgrade a teaching lab Teach your students what an oscilloscope is and how to perform basic measurements with the Educator s Oscilloscope Training Kit DSOXEDK It includes training tools created specifically for electrical engineering and physics undergraduate students and professors It contains an array of built in training signals a comprehensive oscilloscope lab guide and tutorial written specifically for the undergraduate student and an oscilloscope fundamentals PowerPoint slide set for professors and lab assistants For more information refer to www agilent com find EDK Also available are DreamCatcher s full semester application specitic courseware written around Agilent test and measurement equipment www dreamcatcher asia cw With features such as the ability to disable autoscale and the 50 Ohm input data path the InfiniiVision X Series is a perfect choice for education Get your students to quickly put the scope to work Intuitive localized front panel design with pushable knobs for quick access to commonly used oscilloscope functions DSOXEDK Educator s helps students spend more time learning the concepts and Oscilloscope Training Kit less time learning how to use the oscilloscope Enable your students to answer their own questions with t
16. equency 1Hz BW of Scope lt 10 mV div greater of 1 divor5mV 25 ppm 5 ppm per year aging counter 10 mV div 0 6 div Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget InfiniiVision X Series physical characteristics Instrument Dimensions mm Inches Width 380 6 14 98 Height 204 4 8 05 Depth 141 5 5 57 Weight kg Ib Instrument only 3 85 8 5 With accessories 4 08 9 0 Instrument shipping package dimensions mm Inches Width 450 17 7 Height 250 9 84 Depth 360 14 17 Rack mount mm Inches Width 481 6 18 961 Height 221 5 8 72 Depth 189 34 7 454 Standard ports One USB 2 0 high speed device port on rear panel Two USB 2 0 high speed host ports front and rear panel Supports memory devices and printers Optional ports GPIB LAN VGA Reference waveform display 2 internal waveforms or USB thumb drive Waveform storage Set up bmp png csv ASCII XY reference waveforms alb bin lister mask HDFS Max USB flash drive size Supports industry standard flash drives Set ups without USB flash drive 10 internal setups Set ups with USB flash drive Limited by size of USB drive Accessories included Standard 3 year warranty Standard SEC mode Secure Environment Standard Probe N2862B 150 MHz 10 1 passive probe Standard one per channel for 70 and 100 MHz models N2863B 300 MHz 10 1 passive probe Standard one per channel for 200 MHz models N6459 60001 8 channel logic probe and accessory kit S
17. eractive signal source and analysis capability Reference Level FAKTEUR IST Scale BORCE Y Horizontal Channel Select Range Resolution Bandwidth Center Frequency Frequency Spa 7i Channel 1 Use StarvStop exe Ss AutoRange Waterfall View for ASV Spectrogram Measurement Shifts from 99 5 MHz to 100 5 MHz T u Shifts back to 99 5 MHz Close Up Detail on Frequency Shift Keying FSK Character istics with the ASV Spectrogram Measurement Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Other productivity tools Reference waveforms Store up to two waveforms in the scope s non volatile reference waveform memory locations Compare these reference waveforms with live waveforms and perform post analysis and measurements of stored data You can also store waveform data on a removable USB memory device that can be recalled back into one of the available two reference memories of the scope for full waveform measurement and analysis Save and or transfer wave forms as XY data pairs in a comma separated values format csv for PC analysis Save screen images to a PC for documentation purposes in a variety of formats includ ing 8 bit bitmaps bmp 24 bit bitmaps bmp and PNG 24 bit images png Localized GUI and help Operate the scope in the language most familiar to you The graphical user interface built in help system front panel overlays and user s manual are availa
18. et More scope The InfiniiVision 2000 X Series offers entry level price points to fit your budget with superior performance and optional capabilities that are not available in any other oscilloscope in its class Agilent s breakthrough technology delivers more scope for the same budget 3 Anitens Technologies InfiniiVision MSOX 2024A With more scope you can e See more of your signal more of the time with the largest screen in its class the deepest memory and the fastest waveform update rates Do more with the power of 4 instruments in 1 oscilloscope logic timing analyzer WaveGen built in 20 MHz function generator optional and digital voltmeter optional Get more investment protection with the classes only fully upgradable scope including bandwidth Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget See more of your signal more of the time Largest display Fastest update rate Engineering for the best signal visibility starts with the With Agilent designed MegaZoom IV custom ASIC tech largest display Our 8 5 inch WVGA display offers twice nology the InfiniiVision 2000 X Series family delivers up to the viewing area with five times the resolution WVGA 50 000 waveforms per second With this speed you can see 800x480 versus QVGA 320x240 signal detail and infrequent anomalies more of the time Teletrontx PCS VIET en eet erent Thre Hobbett 000000 EE
19. ey Application 2000 X Series WaveGen built in function generator DSOX2WAVEGEN Integrated digital voltmeter DSOXDVM Educator s kit DSOXEDK Mask testing DSOX2MASK Segmented memory DSOX2SGM InfiniView oscilloscope analysis software N8900A Agilent spectrum vsualizer ASV 64997A 2 See pages 20 21 for more detailed information on upgradability and installation process Step 3 Choose your probes Probes 2000 X Series N2862B 150 MHz 10 1 passive probe Standard one per channel for 70 and 100 MHz models N2863B 300 MHz 10 1 passive probe Standard one per channel for 200 MHz models N6459 60001 8 channel logic probe and accessory kit Standard on MSO models or with DSOX2MSO upgrade N2889A 350 MHz 10 1 1 1 passive probe Optional 10070D 20 MHz 1 1 passive probe with probe ID Optional 10076A 250 MHz 100 1 4 kV high voltage passive probe Optional with probe ID N2791A 25 MHz 700 V high voltage differential probe Optional N2792A 200 MHz 10 1 differential probe Optional 1146A 100 kHz 100 A AC DC current probe Optional 3 See page 20 for probe compatibilty table For more information on probes and accessories see the Agilent literature 5968 8153EN Step 4 Add the final touches LAN VGA connection module DSOXLAN GPIB connection module DSOXGPIB Rack mount kit N6456A Soft carrying case and front panel cover N6457A Hard copy manual N6458A Front panel cover only N2747A 16 Oscilloscopes redefined Breakthrough technology delivers more scope
20. he 2000 X Series offers 23 auto mated measurements such as voltage time and frequency as well as four waveform math functions including FFT All of this at a comparable price to the Tektronix TDS2000C oscilloscope Agilent Industry s first economy class mixed signal oscilloscope MSO Agileni The 2000 X Series is the first instrument in its class to offer an integrated logic timing analyzer Digital content is everywhere in today s designs and with an additional 8 inte grated digital timing channels you now have up to 12 chan nels of time correlated triggering acquisition and viewing on the same instrument Buy a 2 or 4 channel DSO and at any time upgrade it yourself to a MSO with a license to turn on those integrated 8 digital timing channels Industry exclusive WaveGen built in 20 MHz function generator Agilent An industry first the 2000 X Series offers an integrated 20 MHz function generator Ideal for educational or design labs where bench space and budget are at a premium the integrated function generator provides stimulus output of sine square ramp pulse DC and noise waveforms to your device under test No need to buy a separate function generator when you can get one integrated in your new oscilloscope Turn on WaveGen at any time by ordering the DSOX2WaveGen option and install the license yourself Integrated digital voltmeter Agilent he An industry first the 2000 X Series offers an integrated 3 digi
21. he AXle Hong Kong 800 938 693 Japan 0120 421 345 mas E Korea 080 769 0800 deia Malaysia 1 800 888 848 http www pxisa org Singapore 1 800 375 8100 PCI eXtensions for Instrumentation Taiwan 0800 047 866 001 2008 PXI modular instrumentation ma pete Ee Other AP Countries 65 375 8100 delivers a rugged PC based high www agilent com quality performance measurement and Europe amp Middle East automation system Belgium 32 0 2 404 93 40 Denmark 45 45 80 12 15 Agilent Channel Partners Finland 358 0 10 855 2100 France 0825 010 700 wwwagilent com find channelpartners 0 125 minute Get the best of both worlds Agilent s Germany 49 0 7031 464 6333 measurement expertise and product Ireland 1890 924 204 breadth combined with channel Israel 972 3 9788 504 544 partner convenience Italy 39 02 92 60 8484 Netherlands 31 0 20 547 2111 Spain 34 91 631 3300 Sweden 0200 88 22 55 United Kingdom 44 0 118 927 6201 For other unlisted countries www agilent com find contactus Revised January 6 2012 Product specifications and descriptions in this document subject to change without notice Agilent Technologies Inc 2012 Published in USA April 12 2012 5990 6618EN Microsoft is a trademark of Microsoft Corporation in the United States e fe Agilent Technologies
22. he localized built in help system that provides quick access by simply pressing and holding any button po i at ial Stretch your budget over the long term 3 Wi Lab Guide and Tutorial for Save money with an industry exclusive built in 20 MHz hidevaelantc thasidesd WaveGen instead of a separate function generator Buy Engineering and Physics what you need today and protect your investment in Students the future with the only oscilloscopes in this class with upgradable bandwidth 8 digital channels MSO WaveGen integrated digital voltmeter and measurement applications Get long scope life and keep repair costs to a minimum with a standard 3 year warranty and an instrument reliability you ve come to expect from the leader in test and measurement equipment Ch Agilent Technologies Optimize lab bench space With 4 instruments in 1 you will save on precious lab bench space by getting an oscilloscope logic timing analyzer WaveGen function generator and integrated digital voltmeter all in one innovative instrument with a footprint that is only 5 57 inches deep With the large 8 5 inch WVGA display you can easily view all signals on one screen with enough viewing area for more than one student to view Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Designed with research and development in mind Find more glitches and infrequent events With the fastest architecture in the ind
23. he vertical scale and offset position knobs will scale and move the signal Pan and zoom redraws the waveform in lt 100 ms CAT 300 Vrms 400 Vpk transient overvoltage 1 6 kVpkCAT II 300 Vrms 400 Vpk with N2862A or N2863A 10 1 probe 300 Vrms 1 mV to 200 mV div 2 V gt 200 mV to 5 V div 50V 20 MHz selectable AC DC 1 MQ 2 5 ns div to 5 ns div to 2 ns div to 5 ns div to 5 ns div to 2 ns div to 50 s div 50 s div 50 s div 50 s div 50 s div 50 s div 25 ppm 5 ppm per year aging time base accuracy reading 0 0016 screen width 100 ps 8 divisions from center screen Horizontally expand or compress a live or stopped waveform Denotes warranted specifications all others are typical Specifications are valid after a 30 minute warm up period and from 10 C firmware calibration temperature 1 mV div and 2 mV div is a magnification of 4 mV div setting For vertical accuracy calculations use full scale of 32 mV for 1 mV div and 2 mV div sensitivity setting 17 Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Performance characterisitics Acquisition modes Normal Peak detect Capture glitch as narrow as 500 ps at all timebase settings Averaging Select from 2 4 8 16 64 to 65 536 High resolution mode 12 bits of resolution when 20 us div Segmented Re arm time 19 us minimum time between trigger events Trigger system Trigger modes e Edge rising
24. me Period frequency rise time fall time width width duty cycle delay A B rising edge delay A B falling edge phase A B rising edge and phase A gt B falling edge Denotes warranted specifications all others are typical Specifications are valid after a 30 minute warm up period and from 10 C firmware calibration temperature 1 mV div and 2 mV div is a magnification of 4 mV div setting For vertical accuracy calculations use full scale of 32 mV for 2 mV div sensitivity setting Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Performance characterisitics Waveform math Operators Add subtract multiply FFD eee Add subtract multiply FFT FFT Windows Hanning flat top rectangular Blackman Harris up to 64 kpts resolution Sources Math functions available between Sources Math functions available between any two channels eeseses i lt lt itiwssCS channels Display BADINCHWVGA eee 8 5 inch WVGA Resolution 800 H x 480 V pixel format screen area Interpolation Sin x x interpolation using FIR filter used when there is less than one sample per column of the display Persistence Off infinite variable persistence 100ms 60s Intensity gradation 64 intensity levels Modes Normal XY XY mode changes the display from voltage versus time scale to a volts versus volts scale Roll Roll Displays the waveform moving across the
25. o anywhere in the data record Navigate in time or between bookmarks View e Up to 8 waveforms simultaneously 1 2 or 4 grids stacked side by side custom layout zoom Measurements e Over 50 automated measurements e View up to 20 simultaneously e User customizable result window size position information e X amp Y markers with dynamic delta values Analyze e 20 math operators including FFT and filters e Up to four independent cascaded math functions e Measurement histogram View Windows Use familiar scope controls to quickly navigate and zoom in to e Analog math spectral measurement results any event of interest simultaneous tabbed or undocked Documentation e Right click to copy e Up to 100 bookmarks e Annotated axis values e Markers with dynamic delta value updates when moved e One step save load setup and all waveforms Analysis Upgrades Optional e Protocol decode for l C SPI RS232 UART CAN LIN FlexRay SATA 8B 10B digRF v4 JTAG MIPI D Phy SVID Ehernet 10G KR PCle 1 2 3 USB 2 3 HSIC e Jitter analysis e Serial data analysis Add bookmarks and call outs to produce friendly and useful documentation Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Other productivity tools Agilent Spectrum Visualizer ASV Software This PC based software package connects to the scope via USB or ethernet connection and uses the Agilent
26. screen from right to left much like a strip chart recorder the waveform moving across the screen from right to left much like a strip chart recorder MSO digital channels Upgradable from DSO Yes sees from DSO Yes MSO channels 8 channels D0 to D7 Maximum sample rate 1 GSa s Maximum record length 50 kpts per channel digital channels only 12 5 kpts per channel analog and digital channels Threshold selections TTL 1 4 V CMOS 2 5 V ECL 1 3 V User definable 8 0 V in 10 mV stops Threshold accuracy 100 mV 3 of threshold settings Maximum input dynamic 10 V about threshold range Minimum voltage swing 500 mVpp Input impedance 100 kQ 2 at probe tip 8 pF Minimum detectable pulse 5 ns width Channel to channel skew 2ns _Channel to channel skew 2ns typical 3 ns maximum eeesesesssssssseseseses lt i lt CSO 3 ns maximum Environmental and safety Power line Powerline consumption 100 watts eee 100 watts Temperature Operating 0 to 55 C Non operating 30 to 71 C Humidity Operating Up to 80 RH at or below 40 C up to 45 RH up to 50 C Non operating Up to 95 RH up to 40 C up to 45 RH up to 50 C Altitude Operating and non operating up to 4 000 m Electromagnetic Meets EMC Directive 2004 108 EC meets or exceeds IEC 61326 1 2005 EN compatibility 61326 1 2006 Group 1 Class A requirement CISPR 11 EN 55011 IEC 61000 4 2 EN 61000 4 2 IEC 61000 4 3 EN 61000 4 3 IEC 6
27. signals per M second to a known good waveform with quick go no go OT Ran ety test results saving you valuable test time while having an more certainty Optimize test bench space With 4 instruments in 1 you will save on precious line bench space by getting an oscilloscope logic timing analyzer WaveGen function generator and integrated digital voltmeter all in one innovative instrument with a footprint that is only 5 57 inches deep With the large 8 5 inch WVGA display you can easily view all signals on one screen even when the scope is sitting far away from the operator Agilent RECO ERED SESE MTEL Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget MSO X 2024A 200 MHz ts Agilent Technologies InfiniiVision Mixed Signal Oscilloscope 2 GSa s 50097 2 0 05 8 5 inch high resolution wide screen display reveals subtle details that most scopes don t show you Do a ana is Pattern 1 XX 2 Ds XXXX XXXX 1110 01190 Trigger Qualifier Channel gt Pattern Pattern Entered Bi i 2 oe oOo BOB OBO Built in USB port WaveGen Get up to eight integrated Industry first digital channels ECE AL SES builtin kton save your work and T generan update your system software quickly Autoscale lets you quickly display any analog or digital Navigation front panel Quickly pan and active signals controls make It easy zoom for analysis automatically to
28. t voltmeter DVM and 5 digit frequency counter inside the oscilloscopes The voltmeter operates through the same probes as the oscilloscope channels however the measurements are de coupled from the oscilloscope triggering system so that both the DVM and triggered oscilloscope measurements can be made with the same connection The voltmeter results are always displayed keeping these quick characterization measurements at your fingertips Turn on DVM at any time by ordering the DSOXDVM option Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Get more investment protection with the industry s only fully upgradable oscilloscope Upgradability Add at the time of your purchase or upgrade later Project needs change but traditional oscilloscopes are e Bandwidth fixed you get what you pay for at the time of purchase Digital channels MSO With the 2000 X Series your investment is protected If WaveGen built in 20 MHz f l you need more bandwidth up to 200 MHz digital chan a eu uiass elt alates nels WaveGen integrated digital voltmeter or measure Integrated digital voltmeter DVM ment applications in the future you can easily add them Measurement applications all after the fact o Mask testing See page 22 for more information on upgradable products Segmented memory o Educators lab kit Mask testing a Whether performing pass fail tests to specified standards in man
29. tandard on MSO models or with DSOX2MSO upgrade Built in help language support for English Japanese simplified Chinese traditional Chinese Korean German French Spanish Russian Portuguese and Italian Certificate of Calibration Documentation CD Interface language support GUI menus English Japanese simplified Chinese traditional Chinese Korean German French Spanish Russian Portuguese and Italian Localized power cord For MET CAL procedures click on the Cal Labs solutions link below Cal Labs Solutions http www callabsolutions com MetCALandCLS asp These procedures are FREE to customers 22 Probe Compatibility Table To assist you in selecting the proper probe for your application Use our probe compatibility table below to find the probes that are recommended for use with your 2000 and 3000 X Series InfintiVision oscilloscope Probe Type Probe Model MS0O DSO 2000 X Series MS0O DSO 3000 X Series Passive probes N2862B 10 1 150 MHz Recommended Recommended included in 70 100 MHz models N2863B 10 1 300 MHz included in 200 MHz models N2890A 10 1 500 MHz included in 350 500 MHz models N2889A 1 1 10 1 350 MHz Recommended Recommended High voltage passive probes 10076D 4 kV Recommended Recommended N2771B 30 kV Recommended Recommended Differential active probes 1130A 1 5 GHz Incompatible Compatible 1141A 200 MHz use with 1142A Incompatible Recommended N2791A 25 MHz Recommended Recommended N2891A 70 M
30. ufacturing or testing for infrequent signal anomalies in R amp D debug the mask test option can be a valuable productivity tool The 2000 X Series features the industry s only hardware based mask testing and can perform up to 50 000 tests per second Segmented memory When capturing low duty cycle pulses or data bursts you can use segmented memory acquisition to optimize acquisition memory Segmented memory acquisition lets you selectively capture and store important segments of signals without capturing unimportant signal idle dead time Segmented memory acquisition Is ideal for applica tions including packetized serial pulses pulsed laser radar bursts and high energy physics experiments Up to 25 segments can be captured on the 2000 X Series models with a minimum re arm time under 19 us Oscilloscopes redefined Breakthrough technology delivers more scope for the same budget Get more investment protection with the industry s only fully upgradable oscilloscope InfintiView Oscilloscope Analysis Software N8900A Agilent s InfiniiView PC based analysis oscilloscope soft ware allows you to do additional signal viewing analysis and documentation tasks away from your scope Capture waveforms on your scope save to a file and recall the waveforms into InfiniiView The application supports a variety of popular waveform formats from multiple oscilloscope vendors and includes the following features Navigate e Pan and zoom t
31. ustry up to 50 000 waveforms sec you can see jitter infrequent events and more subtle signal details that other oscilloscopes miss Capture and view more of your signals at once With integrated eight digital timing channels MSO models you can get up to 12 channels of time correlated triggering acquisition and viewing on the same instrument with no compromise to the oscilloscopes waveform update rate Don t need an MSO right now No problem just upgrade later when you need it Optimize lab bench space With 4 instruments in 1 you will save you money and precious lab bench space by getting an oscilloscope logic timing analyzer WaveGen function generator and integrated digital voltmeter all in one innovative instru ment with a footprint that is only 5 57 inches deep With the large 8 5 inch WVGA display you can easily view all signals on one screen with enough viewing area for more than one engineer to view Agilent Make the most of a limited budget Project needs change but traditional oscilloscopes are fixed you get what you pay for at time of purchase With the 2000 X Series your investment is protected If you need more bandwidth up to 200 MHz 8 digital channels MSO WaveGen integrated digital voltmeter or measure ment applications like mask testing and segmented memory in the future you can easily add them all when you need to Get a long scope life and keep repair costs to a minimum with a standard
32. z 100 200 350 500 MHz 1 GHz Maximum sample rate 1 GSa s per channel 2 GSa s per channel 2 GSa s half channel interleaved mode 2 5 GSa s on 1 GHz models 4 GSa s half channel interleaved mode 5 GSa s on a 1 GHz models Maximum memory depth 100 kpts standard 2 Mpts standard 4 Mpts optional Option DSOX3MemUp Waveform update rate 50 000 waveforms per second 1 000 000 waveforms per second WaveGen built in 20 MHz Yes Option DSOX2WAVEGEN Yes Option DSOX3WAVEGEN function generator No AWG capability With AWG capability Integrated digital voltmeter Yes option DSOXDVM Yes option DSOXDVM Search and navigate No Yes Serial protocol analysis No Yes multiple options Segmented memory Yes Option DSOX2SGM Yes Option DSOX3SGM Mask limit testing Yes Option DSOX2MASK Yes Option DSOX3MASK AutoProbe interface No Yes Need more memory or a Bigger Screen See the InfiniiVision 000B Series oscilloscopes e 12 1 display nearly 40 larger than the nearest competitor e 100 MHz to 1 GHz DSO and MSO models e 8 Mpts memory standard e Upgradability for MSO channels and Measurement applications e Hardware based measurement applications including serial decode e Xilinx FPGA dynamic probe support e Altera FPGA dynamic probe support e Standard LAN USB and XGA video out connectivity See www agilent com find 7000 for more details 2 Oscilloscopes redefined Breakthrough technology delivers more scope for the same budg