Home

H110 Series meters: H115, H116, H117

image

Contents

1. ANAHEIM SCIENTIFIC User Manual Models H115 H116 H117 Light UVA Solar Power Meters H117 Light UVA Solar Power Table of Contents 1 INTRODUCTION Qu cccccseccsesseccnsseueeeuseceseusesesseuseaueeuseeuesueeeeesueseeesness 2 2 SAFETY SUMMARY eege 2 3 COMPLIANCE STATEMENTS vcsicicciectaetaevacieteccttectiesirechectiesdiereinisinct 3 4 PRODUCT CONTENTS AND INSPECTION cccccsscsesseseseeeeeeeees 3 5 DEVICE DESCRIPTION cccccscccescnessesseesecesesseuseaneeseeesseeeenessaeees 5 Sl EE 2 9 2 CD elen e E 6 6 OPERATING PROCEDUREG cccccsscsseeeeeseeseeeeeeseueeeeseeeeaesensseess 7 Ol RING TE 7 6 2 ZERO ADJUSTMENT ee 8 6 3 VIEWING AND SETTING THE CLOCK ccccccecceccecceceeceeceeeeeeeeeeeeeeeeeeeeeeees 8 6 1 AUTO RECORDING TIME GETUp 9 6 2 VIEWING RECORDS geet 10 6 3 MAX MIN AVG HRtconnp 11 6 4 SINGLE DATA RECORD EE 11 6 95 AUTO POWER EE 12 6 6 RELATIVE DEDUCTION V ALUE 76 arccasene ascents cudcanesorodumesuadesseskedeemnaaide 12 6 7 BATTERY REPLACEMENT asasssssnsnsnrnnnnnnnrnnrnrnrnrnrnrnnrrnrennrrnrnrnenenenenne 13 7 TECHNICAL SPECIFICAT TIONS sasasnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 14 7 1 GENERAL SPECIFICATIONS ccccccccceecescccecceeeeseueceueueueeaueeueuesaueas 14 7 2 SOLAR POWER SENSOR sasssessssssernnnnnenenrnnnrenrnrnnntnnrnrnnnrnnennnnnnerenenae 14 To UVA SENOR eee ce ee ne ee eee 15 Te LIGHT SENSOR bereede 15 7 5 RELATIVE SPECTRAL SENSIT
2. 5 2 LCD description LD MAX RIX CU II JORIA muW cm IH cies CIC N amb unhand NM 19 1 Numeral reading value 2 Time unit hour minute month second 3 Memory reading symbol 4 AVG symbol 5 W m mier W cm unit 6 Btu h ft unit anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 6 Operating Procedures 6 1 Starting Up lf changing the sensor make sure the meter is off while changing Push gt button turn on the meter Push 4 gt button again to turn off the meter Hold button and push gt button to change the measuring unit W m7 gt gt Btu ft h gt gt W m or Lux gt gt Fc gt gt Lux Push GT button to lock display data on the LCD Push P button again wegl raaa Don DDp d JI i JI anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 6 2 Zero Adjustment e Push button and attach the cap on the sensor 0 00 will appear on the LCD Make sure that the cap is attached on the sensor f the zero adjustment has not been made correctly some digits will appear on the LCD instead of 0 00 and the word CAP will also appear on the LCD to inform you that the cap is not completely covering the sensor np 6 3 Viewing and Setting the Clock ADJ CAP Press D button to
3. button the auto power off symbol will not display on the LCD fyou want enable auto power off please hold button and push button again The auto power off symbol will display on the LCD Auto power off time is 30 minutes E IIL ninje ggi ITS S a ee AD sslenclgalanglnfbnahuginnnht wl DT DT TTT TTTOTTTTTHTTTTTTTT 8 13 2t 30 A 19 Zi 30 6 6 Relative Deduction Value Hold 2 button and push button to save the current measured result 100 will show at first Then future measured results will be divided by the saved result and given as a percentage on the LCD e eg The transmission percent Second measured value first measured value x100 Hold button and push ES button again to exit REL mode anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 13 6 7 Battery Replacement WARNING If the symbol appears on the LCD please replace the battery immediatel W Te de Turn off the instrument Open the battery cover and remove the battery Replace with a 9V battery Install the battery cover anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 14 7 Technical Specifications 7 1 General Specifications General Specifications H115 H116 H117 Battery Life Approximately 100 hours Display 3 LCD Samplin
4. 22 FAKNAHEIM SCIENTIFIC 22820 Savi Ranch Parkway Yorba Linda CA 92887 www anaheimscientific com 2013 Anaheim Scientific anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726
5. 9288 7 www anaheimscientific com anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 21 10 2 Limited Two Year Warranty Scientific warrants to the original purchaser that its products and the component parts thereof will be free from defects in workmanship and materials for a period of two years from date of purchase Anaheim Scientific will without charge repair or replace at its option defective product or component parts Returned product must be accompanied by proof of the purchase date in the form of a sales receipt To help us better serve you please complete the warranty registration for your new instrument via our website www anaheimscientific com Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty is void if the serial number is altered defaced or removed Anaheim Scientific shall not be liable for any consequential damages including without limitation damages resulting from loss of use Some states do not allow limitations of incidental or consequential damages So the above limitation or exclusion may not apply to you This warranty gives you specific rights and you may have other rights which vary from state to state anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726
6. see the Year Month Date hour and Second Press it again to keep changing through these values This meter s clock uses 24 hour time setting Hold WR button and Push button to setup the clock ge Push or to select the setting to adjust And press ES button to skip from hour to day and day to month etc 8 or es ES T SS ze ge I 32 iay LU Wh LU Hour day Monthinn anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 pa Da IT ee ECU IECH AE eu ear Zeck Minute Push D button to store the setting e Years allowable 2000 2099 Display will show 00 99 6 1 Auto Recording Time Setup Hold button and push EN button to go into the setup mode TU ser CCT DU LIL Push button again to go into Auto Recording Time Setup or Q button to change digit or O to select the setting to adjust Push Push Press O button to skip from minute to hour and press O button anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 10 f you do not want to use auto power off you can set auto power off time to be 00 00 00 Lt LiL HH Maximum auto recording time 23 hours 59 minutes 59 seconds Minimum auto recording time 1 second 6 2 Viewing Records Hold button and Push oe button to view recor
7. IVITY ccccccscecececeeesceseceeceeeesenescersoes 16 20 EXTERNAL DC POWER EE 16 7 7 GverEMREOUIREMENTS 17 8 SOFTWARE INS EK EIN eebe 17 ZWEE EN Le Etc pe wiser settee SEEGE 19 10 SERVICE INFORMATION ccccscccseccescceseusseeseeeeeeseusseussaeeeessaeees 19 10 1 SERVICE REPAIR OR CALIBRATIONS ececececcececececeeeceeaeaeaeeeeeeeeess 19 10 2 LIMITED TWO YEAR WARRANTY 21 anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 1 Introduction Thank you for purchasing an H110 Series meter from Anaheim Scientific With this meter you will have highly accurate results for Illumination H117 solar H115 H117 or UVA H116 H117 light measurements Light and durable the H110 Series meters will provide years of reliable service The H110 Series applications include Lighting for warehouses factories office buildings restaurants schools library and hospitals Also photography videography building security UV curing suntan lighting etc The H100 Series features Convenient easy to read data displayed on the LCD screen Real time data Data hold function The H110 Series of light meters Auto ranging offers 3 Back light models with different light sensors e Auto power off and disable auto power Model E USB PC interface Data logging capacity up to 45 000 Solar Power UVA readings and Light Low battery indicator Over
8. age to the instrument is evident a description of the damage should be noted on the carrier s receipt and signed by the driver or carrier agent Save all shipping packaging for inspection Forward a report of any damage to the agent through which the unit is procured anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 Retain the original packing in case subsequent repackaging for return is required Use of the original packing is essential After the mechanical inspection verify the contents of the shipment The items included in this package are H11X Meter Carrying case User s Manual 9V Battery Mini USB 4P Male to USB A Type Cable Installation CD AC to DC 9v 300mA power supply solar sensor H115 UVA Sensor H116 Solar UVA Illumination sensors H117 anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 2 Device Description 5 1 Diagram 3 EECH BR 1 Sensor Input connector 2 LCD 3 Power Button 4 Backlight Down Button 5 Hold Up Button 6 ADJ SET Button 7 MAX AVG Min Button 8 Time MEM button 9 Record UNIT switch Button 10 External power DC 9V 11 USB interface 12 Sensor Probe input 13 UVA Sensor 14 Illumination sensor 15 Solar Sensor NN anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726
9. ds wl x ppe LL LI ee or O button to scroll through the records e Push SZ to change between Btu ft h gt gt Wim gt gt Btu ft h Or FC gt gt LUX gt gt FC units W m2 INI TERR Bum TE LOD HM Li h II f CH LI anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 11 Push button to view the time data H M M D year sec Dn ITT Ten See en uMI UU wf west U UL sec CU Hold button and push D button again to exit viewing records mode DA Max Min Avg Record Press key to show the current MAX MIN and AVG values Press key to switch to the next display The display switches from MAX to MIN MIN to AVG and AVG to MIN Follow the figure circles go J _ 9008 0008 WM Se 8 Le Seco Hu HEN Press and hold OD key to disable this function The maximum storage is up to 99 minutes and 99 seconds cJ e Press and hold button for more than 2 seconds to exit this mode 6 4 Single Data Record Push button The meter will save the current measured result and REC will also appear on Lie LCD TITLE 1 1a 29 10 anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 12 6 5 Auto Power Off f you want disable auto power off please hold button and push ED
10. g 4 times second Power Off Manual by push button or auto shut off after approx 30 minutes Power v battery or AC to DC Adaptor 9v 300MA Dimensions _ 130 L x 56 W x 38 H mm Weight 250g ZA Solar Power Sensor Solar Power Sensor H115 H117 Measuring Range 40 00 Wim 400 0 Wim 2000 W m 13 Btu h ft 127 Btu h ft 634 Btu h ft Resolution 0 01 Wim 0 1 Wim 1W m 0 01 Btu h ft 0 1 Btu h ft 1 Btu h ft Accuracy Typically within 10 W m 3 Btu h ft or 5 hichever is greater in sunlight Additional temperature induced error 0 38 W m C 0 12 Btu h ft C from 25 C pectral Response 400 1100 nm Auto Measurement amp 0 01 Wim 2000 W m Ranges 0 01 Btu h ft 634 Btu h ft anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 15 7 3 UVA Sensor UVA Sensor H116 H117 Peak Sensitivity Sensor Photo d ion fi hoto diode amp UVA color correction filter 7 4 Light Sensor Light Sensor H117 Sensor Silicon photodiode andfilter o Measuring Range 40 00 400 0 4000 40000 400000 Lux 40 400 4000 40000 Foot candles Resolution Dot 0 1 1 10 100 Lux Accuracy 3 Calibrated to standard incandescent lamp 2856 K 6 other visible light source Angle Deviation from 30 2 Cosine 60 6 Characteristics 80 25 avelength 550 nm oe Wim 2000 W m Ranges 0 01 B
11. ktop icon Use the USB cable to connect the meter and computer according to the drawing select the desktop icon Light Meter and click twice on left key of the mouse to run the program You should now see the LCD from your light anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 19 meter showing on the computer screen If no digits appear on the light meter LCD the one showing on the computer then right click to Tools Connect You may also want to try manually turning on the light meter and or reconnecting the USB Once the LCD on the computer screen reflects what is showing on the actual meter your program is running properly Right click on the mouse to see your options Select Tools Download to access the data recorded on your meter 9 Maintenance This is a precision instrument To guarantee its performances be sure to use it or keep it stored within the suitable environmental conditions given in the Safety Summary and Technical Specifications Be sure to turn it off after use To store the instrument for an extended period of time remove the batteries to avoid any damage to its inner components 10 Service Information 10 1 Service Repair or Calibrations The following are instructions regarding policies for servicing repairing or calibrating Anaheim Scientific products Turnaround time is usually less than ten 10 working days unless ex
12. load indicator Maximum Minimum Average record and elapse time Auto zero adjustment 2 Safety Summary CAUTION Adhere to the following conditions for safe and effective usage of this meter Operating altitude Below 2 000m Ge Do not store this device in direct sunlight or where it is hot and or damp anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 Remember to turn OFF the power after use For long storage remove the battery to prevent the battery from leaking to cause damage to the parts inside Clean the device with a dry soft cloth Wet cloths liquid and water are prohibited 3 Compliance Statements Caution This symbol indicates that the equipment and its accessories are subject to special collection and disposal procedures This tester was designed in accordance with EMC Standards in force and its compatibility has been tested in accordance with EN61326 1 2006 Meets JISC1609 1993 and CNS 5119 General Class A Specifications 4 Product Contents and Inspection This unit is tested prior to shipment It is therefore ready for immediate use upon receipt An initial physical inspection should be made to ensure that no damage has been sustained during shipment Inspect the packing box on receipt for any external damage If any external damage is evident remove the instrument and visually inspect its case and parts for any damage If dam
13. pedited service is requested and pre arranged anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 20 Send an email to service anaheimscientific com requesting an RMA number specifying your request for either service repair and or calibration with your products model number Once you receive a reply from service anaheimscientific com you will be asked to ship prepaid to the address below Package the unit carefully using filler or bubble wrap and if possible ship in the original box Ship each unit separately Anaheim Scientific is not responsible for any shipping damage that may occur Include a packing list with each unit shipped stating what type of service is required and include the return shipping information name address and telephone number lf the unit is in warranty please provide the following proof of purchase or copy of the original invoice lf the unit is out of warranty prepayment is required by Check Money Order or Credit Card Return all merchandise to Anaheim Scientific with pre paid shipping The flat rate repair charge for Non Warranty Service does not include return shipping Return shipping to locations in North American is included for Warranty Service For overnight shipments and non North American shipping fees please contact Anaheim Scientific Anaheim Scientific ATTN Service Repair 22820 Savi Ranch Parkway Yorba Linda CA
14. tu h ft 634 Btu h ft anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 16 7 5 Relative Spectral Sensitivity The deviation from the comparative standards for luminosity is determined by JIS standard C 1609 1993 Peak sensitivity wavelength 550 nm Typ Ta 23 C VO RELATIVE SENSITIVITY WAVELENGTH nm GIE Luminosity Function 7 6 External DC Power External AC to DC adapter Voltage 9VDC 8 14 VDC Max Socket pin Positive Ground Casing External Diameter 5 5mm internal Diameter 2 1 mm lt S e anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 17 7 7 System Requirements CPU Pentium 1000MHZ RAM SDRAM 256MB Hard Disk 200MB OS Windows 2000 Windows XP Display 800x600 256 colors 8 Software installation Please insert the CD into your PC to install the software Please select PL 2032 Driver folder Click twice on the PL 2303 Driver Installer to install the USB driver anaheimscientific com Technical data subject to change without notice Anaheim Scientific 2013 v20130726 18 Now select the H117 Windows software folder to install the Light Meter program on your computer Double click on the Setup file If you see the unknown publisher window select yes Take out the CD from PC after completing the installation of the des

Download Pdf Manuals

image

Related Search

Related Contents

Réglementation commerciale Fév. 2005  Iomega Desktop Hard Drive 320 GB USB 2.0/FW400/FW800 EU & UK  Videk 9466PS-10 keyboard video mouse (KVM) cable  Processor Expert Help About Processor Expert  The dramatist package User Guide  www.gatoo.es  Samsung CLX-3175 用戶手冊  取扱説明書  Maxi VE 420  Dynamic Analysis and Profiling of Multi  