Home
Quick Reference Guide Barometric Compensation
Contents
1. Compensate Filter Export selected tim Regular Monitoring POR Uncompensated Parth Compensated Compensated Filter time senes starting from 1 1 1990 E 12 00 00 AM to 6 19 2015 E 2 20 28 PM Start Date Time End Date amp Time Download Date amp Time tucson micro diver 8 21 2009 8 00 00 AM 6 25 2010 11 30 00 AM 6 18 2015 2 18 24 PM Select All 3 Select the BaroComp button from the Data dialog toolbar 4 Select the desired barometric compensation method from the BaroComp dialog shown on following page You may choose from five barometric compensation methods a Water Column above Diver Water level with respect to Top of Casing using Cable Length Water level with respect to Top of Casing using Manual Measurement Water Level with respect to VRD using Cable Length Water Level with respect to VRD using Manual Measurement Dano Note Each barometric compensation method requires that certain data be entered before the compensation can be performed Please refer to the Diver Office user s manual for more information on the data requirements for each compensation method 4 Page Version June 2015 5 2488 vanEssen instruments Barometric Compensation _ _ pad Choose one of the following three options E _ Water level with respect to top of _ Water level with respect to vertical Water column above Diver C casing O reference datum Obtain Diver position from Obtain Diver position from Use t
2. Import Diver Gate Help OeaA amp amp Q O ee New Open Diver Diver Gate Data BaroComp Help 5 H BaroComp Example Monitoring Point Settings H 2 tucson barometer tucson micro diver AA a f tucson micro diver Monitoring Point Type C Barometer a is WAN I I Ves S a iv Upgrade to Diver Office Premium 1 From the Barometer Monitoring Point dropdown list select baro waterloo 2 Enter a value for the cable length A if the barometric compensation should calculate the depth to water 3 Enter a value both A and for the top of casing B if the barometric compensation should calculate the water level with respect to Mean Sea Level The window should now be similar to the window shown below 2 Page Version June 2015 5 2488 vanEssen yr instruments Diver Office BaroComp Example Project View Preferences Import Diver Gate Help OgeaiA amp OQ New Open Diver Diver Gate Data BaroComp Help fH BaroComp Example Monitoring Point Settings 2 tucson barometer i aM EENE A tucson micro diver Monitoring Point Type Barometer ad l wa a Upgrade to Diver Office Premium Compensating Diver Data lt lt 1 Click the BaroComp button from the main toolbar You may also right click on the data set in the project tree to go directly to the BaroCompensation dialog Version June 2015 5 2488 Page 3 vanEssen yr instruments
3. his method to export data to an Use this method to compare water level etemal database with diferent wells 5 Once the method is chosen select the BaroComp button to perform the barometric compensation Note If the compensation fails the type of missing information will be indicated in the log dialog 6 When the compensation is complete the barometric compensation log will show displaying a summary with details date time 6 18 2015 2 21 52 PM barometric compensation with water column above Diver compensated 1 time series partly compensated 0 time series uncompensated 0 time series tucson micro diver 6 21 2005 8 00 00 AM 6 25 2010 11 30 00 AM partly compensated 0 time series uncompensated 0 time series h Version June 2015 5 2488 Page 5 vanEssen yr instruments 7 Click the Close button to finish You can now view the compensated data in the time series table and plot You will notice that the time series symbol in the Project Tree will change once compensation has been performed mh Lr means that the data was Partially Compensated be means that all the data in the time series was Compensated Li means that the data is Uncompensated 6 Page Version June 2015 5 2488
4. vanEssen yr instruments Quick Reference Guide Barometric Compensation Contents Introduction Importing Sample Data Setting the barometer Compensating Diver Data Werer Introduction This document outlines the basics to perform the barometric compensation Please refer to the Diver Office help for more details Importing Sample Data Diver Office comes with example data The default folder is C Program Files Diver Office Examples 1 In Diver Office click on the menu bar item Import gt Example Data In the dialog that opens navigate to the Waterloo DAT files folder C Import Diver Data elon di Drver Office Examples Tucson DAT files N ai Organize New folder UY Favorites Name Date modified Tucson barometer DAT 7 7 2014 9 41 AM DAT File Libraries _ Tucson Micro Diver DAT 7 7 2014 9 41 AM DAT File jE Computer ci Network 4 nm Filename Tucson Micro Diver DAT Tucson baromi 2 Select the two files and click Open Setting the barometer One of the imported data series is now shown Click on Waterloo in the tree view on the left The screen should no look something like the window shown below Note that the Barometer Version June 2015 5 2488 Page 1 vanEssen yr instruments Monitoring Point field is blank To perform the barometric compensation this field must contain a value ra Diver Office BaroComp Example Project View Preferences
Download Pdf Manuals
Related Search
Related Contents
arantie - Auchan . com HP 8800 Router Series Installation Manual Manuel de l'opérateur 取扱説明書 iGrants User Manual - District Samsung MW123ST/XSG دليل المستخدم Copyright © All rights reserved.
Failed to retrieve file