        DIGIPOX 指套式脉搏血氧仪说明书
         Contents
1.   in glow and near infrared  zones  Operation principle of the instrument  Photoelectric Oxyhemoglobin Inspection  Technology is adopted in accordance with Capacity Pulse Scanning and Recording  Technology  so that two beams of different wavelength of lights  660nm glow and 940nm  near infrared light  can be focused onto a human nail tip through a clamping finger type  sensor  A measured signal obtained by a photosensitive element  will be shown on the  Oximeter   s display through process in electronic circuits and microprocessor shown on  the Oximeter   s display through electronic circuits and a microprocessor     Diagram of Operation Principle  1  Red and Infrared ray Emission Tube  2  Red and Infrared ray Receipt Tube    Precautions for use    1 Do not use the pulse oximeter in an MRI or CT environment       2 Do not use the pulse oximeter in situations where alarms are required  The device  has no alarms     wo    Explosion hazard  Do not use the pulse oximeter in an explosive atmosphere     A    The pulse oximeter is intended only as an adjunct in patient assessment  It must be  used in conjunction with other methods of assessing clinical signs and symptoms     5 Check the pulse oximeter sensor application site frequently to determine the  positioning of the sensor and circulation and skin sensitivity of the patient     6 Do not stretch the adhesive tape while applying the pulse oximeter sensor  This may  Cause inaccurate readings or skin blisters     J    Before use  
2.  as 30 hours     5  Dimension    Length  56mm  62mm   Width  32mm 38mm   Height  34mm 38mm   Weight  45g 60g  including two AAA batteries     6  Environment Requirements    Operation Temperature  5  40  C   Storage Temperature   20 55  C   Ambient Humidity   lt 80   no condensation in operation    lt 93   no condensation in storage    7  Measurement Performance in Low Perfusion Condition  required the test  equipment  BIO TEK INDEX Pulse Oximeter tester  the pulse wave is available without  failure when the simulation pulse wave amplitude is at 6      8  Interference Resistance Capacity against Ambient Light  Device works normally  when mixed noise produced by BIO TEK INDEX Pulse Oximeter tester     Declaration    EMC of this product complies with IEC60601 1 2 standard     The materials which the user can come into contact have no toxicity and no action on  tissues comply with IS010993 1  ISO010993 5 and IS010993 10     Guidance and manufacturer   s declaration     electromagnetic       emissions for all EQUIPMENT and SYSTEMS    Guidance and manufacturer   s declaration     electromagnetic emission    The Pulse Oximeter is intended for use in the electromagnetic environment specified  below  The customer or the user of the Pulse Oximeter should assure that it is used  in such an environment     Emission test Compliance Electromagnetic environment     guidance  RF emissions Group 1 The Pulse Oximeter uses RF energy only for its  CISPR 11 internal function  Therefore  its RF em
3.  finger with alcohol before and after each test   The rubber  inside of the Oximeter is medical rubber  which has no toxins  and is not harmful to the  skin      When your finger is inserted into the Oximeter  your nail  surface must be upward           Operation Instructions    Power Switch    Low Voltage Lamp    Pulse bar graph Oxygen Saturation    Pulse Rate       The Pulse bar graph displays corresponding with the patient   s pulse beat  The height of  the bar graph shows the patient   s pulse strength        Product Accessories    1  One strap  2  Two batteries  3  One user   s manual       Battery Installation    1  Put the two AAA batteries into battery compartment in correct polarities   2  Push the battery cover horizontally along the arrow shown as below   Notes       Battery polarities should be correctly installed   Otherwise  damage may be caused to the  device       Please put in or remove batteries in right  order  or may cause damage to the device  bracket      lt  gt  Please remove the batteries if the Oximeter  will not be used for a long time           Strap installation  i Thread thinner end of the strap through the loop   2  Thread thicker end of the strap through the threaded end before pulling it tightly        Calibrating the pulse oximeter  1  The functional tester cannot be used to assess the accuracy of the oximeter     2  The test methods used to establish the SpO  accuracy is clinical testing  The  oximeter used to measure the arterial haemoglobin
4.  oxygen saturation levels and  these levels are to be compared to the levels determined from arterial blood  sampling with a CO oximeter     3  Index 2 made by Bioteck company is a function tester  Set Tech to 1  R curve to 2   then user can use this particular calibration curve to measure the oximeter     Maintenance and Storage    le Replace the batteries in time when low voltage lamp is lighted   2  Clean surface of the fingertip oximeter before it is used in diagnosis for patients   3  Remove the batteries inside the battery cassette if the Oximeter will not be    operated for a long time     4  It is best to preserve the product in a place where ambient temperatures is   20  C  55  C   4  131   F  and relative humidity is  lt 93      5  It is recommended that the product should be kept in a dry environment anytime   A wet ambient might affect its lifetime and even might damage the product     6  Please follow the law of the local government to deal with used battery        Detailed descriptions of product functions    1  Display Type  LED    2  SpO    Measurement range  70 99   Accuracy  80  99    2   70  80   3    lt 69  no definition     3  Pulse Rate    Measure range  30 235 BPM   Accuracy  30 99bpm   2bpm  100 235bpm   2   Pulse Intensity  Bargraph Indicator    4  Power Requirements   Two AAA alkaline Batteries  Power consumption  Less than 40mA    Low power indication   Xh  Battery Life  Two AAA 1 5V  600mAh alkaline batteries could be continuously operated  as long
5. OPERATOR   S  MANUAL    V4 0C1  Fingertip Pulse Oximeter    sm    General Description    Oxygen Saturation is a percentage of Oxyhemoglobin  HbO2  capacity  compounded  with oxygen  by all combinative hemoglobin  Hb  capacity in blood  In other words  it is  consistency of Oxyhemoglobin in blood  It is a very important parameter for the  Respiratory Circulation System  Many respiratory diseases can result in oxygen  saturation being lowered in human blood  Additionally  the following factors can reduce  oxygen saturation  Automatic regulation of organ dysfunction caused by Anesthesia   Intensive Postoperative Trauma  injuries caused by some medical examinations  That  situation might result in light headedness  asthenia  and vomiting  Therefore  it is very  important to know the oxygen saturation of a patient so that doctors can find problems in  a timely manner     The fingertip pulse Oximeter features small size  low power consumption  convenient  operation and portability  It is only necessary for a patient to put one of his fingers into  the fingertip photoelectric sensor for diagnosis  and a display screen will show oxygen  saturation  It has been proven in clinical experiments that it also features high precision  and repeatability     Measurement principle    Principle of the Oximeter is as follows  A mathematical formula is established making  use of Lambert Beer Law according to Spectrum Absorption Characteristics of  Reductive hemoglobin RHb  and Oxyhemoglobin  HbO2
6. carefully read the manual           The pulse oximeter has no SpOz alarms  it is not for continuous monitoring           Prolonged use or the patient   s condition may require changing the sensor site  periodically  Change sensor site and check skin integrity  circulatory status  and  correct alignment at least every 4 hours     10 Inaccurate measurements may be caused by autoclaving  ethylene oxide sterilizing   or immersing the sensors in liquid     11 Significant levels of dysfunctional hemoglobins  such as carbonxy  hemoglobin or  methemoglobin  may affect the readings     12 Intravascular dyes such as indocyanine green or methylene blue    13 SpO  measurements may be adversely affected in the presence of high ambient light   Shield the sensor area  with a surgical towel  or direct sunlight  for example  if  necessary     14 Excessive patient movement may cause inaccurate readings   15 High frequency electrosurgical interference may cause inaccurate readings   16 Venous pulsations may cause inaccurate readings     17 Placement of a sensor on an extremity with a blood pressure cuff  arterial catheter  or  intravascular line     18 The patient has hypotension  severe vasoconstriction  severe anemia  or  hypothermia     19 The patient is in cardiac arrest or is in shock   20 Fingernail polish or false fingernails may cause inaccurate SpO2 readings     Follow local ordinances and recycling instructions regarding disposal or  recycling of the device and device components  incl
7. issions are  very low and are not likely to cause any  interference in nearby electronic equipment   RF emission Class B The Pulse Oximeter is suitable for use in all  CISPR 11 establishments  including domestic  establishments and those directly connected to  the public low voltage power supply  network  that supplies buildings used for domestic  purposes   Possible Problems and resolutions  Problems Possible reason Solution  SpO  or PR 1  Finger is not inserted correctly 1 Retry by inserting the finger  can not be 2  Patients Oxyhemoglobin value is 2  Try some more times  If you  shown too low to be measured can make sure no problem is  normally existing in the product     Please go to a hospital timely  for exact diagnosis   SpO or PRis 1  Finger might not be inserted deep 1  Retry by inserting the finger  shown enough  2  Try not to move  unstably 2  Finger is trembling or patient s  body is in movement status     The Oximeter 1  Power of batteries might be 1  Please replace batteries    can not be inadequate or not be there at all 2  Please reinstall the batteries  poweredon 2  Batteries might be installed 3  Please contact with local  incorrectly customer service centre  3  The Oximeter might be damaged  Indication 1  The product is automatically 1  Normal  lamps are powered off when no signalis 2  Replace the batteries  suddenly off detected longer than 8 seconds  2  Power quantity of the batteries is  started being inadequate     Error3    or 1  Low power 1  Change ba
8. tteries     Error4    is 2  Receiving tube being shielded or 2  Please contact local customer  displayed on damaged together with broken service center  screen connector  3  Please contact local customer  3  Mechanical Misplace for service center  receive emission tube 4 Please contact local  4  Amp circuit malfunctions  customer service center     Error     is 1  Low power 1 Please change battery  displayed on 2  Emission tube damaged  2 Please contact local  screen 3  Current control circuit customer service center    3 Please contact local  customer service center    Symbol Definitions    malfunctions                    Symbol Definition        Type BF applied part     N Attention  consult accompanying documents     SpO2 Oxygen saturation   BPM Heart rate  BPM        Low power indication    2X No SpO  Alarm  C  Power switch    SN Serial No     Applicable models    MD300C1 MD300C1C MD300C12 MD300C12 P MD300C13 MD300C14  MD300C1 E MD300C15 MD300C16 MD300C17 MD300C18 MD300C19  MD300C10 MD3800C1A MD300C1B MD300C1D MD300C1E                         Note  The illustration used in this manual may differ slightly from the appearance  of the actual product     ad Beijing Choice Electronic Technology Co  Ltd     BailangyuanB1127 1128 Fuxing R A36  100039 Beijing    PEOPLE S REPUBLIC OF CHINA  EiffestraBe 80 20537    EC REP Hamburg GERMANY      Shanghai International  Holding Corp GmbH Europe  0123    ALL RIGHTS RESERVED  Issue date  25 February 2010    
9. uding batteries     Product Properties    1 Operation of the product is simple and convenient   2 The product is small in volume  light in weight and convenient in carrying   3 Power consumption of the product is low and the two AAA batteries can be    operated continuously for 30 hours     4 A low voltage warning will be indicated in visual window when battery voltage is  so low that normal operation of the oximeter might be influenced     5 The product will automatically be powered off when no signal is in the product for  longer than 8 seconds     Product Operation Scope    Fingertip PULSE OXIMETER is a portable non invasive  spot check  oxygen saturation  of arterial hemoglobin  SpO   and pulse rate of adult and pediatric patient at home  and  hospital  including clinical use in internist surgery  Anesthesia  intensive care etc   It is  not for continuously monitoring     The PULSE OXIMETER requires no routine calibration or maintenance other than  replacement of batteries     Operation Instructions    1 Install two AAA batteries into battery cassette before closing its cover   2 Place clamp over finger nail as the following diagram    3 Insert one finger into rubber hole of the Oximeter fully    4 Press the switch for one time on front panel    5 Finger and body should not tremble during measuring    6 Read corresponding data on the display screen     Note  Please use medical alcohol to clean the rubber  inside the Oximeter  that touches  the finger  Also  clean the test
    