Home

User Manual - Rackmount Solutions Pro

image

Contents

1. Connection to computer over IP P 4 lt Part 3 gt IP Initial Setup P 5 Before Installation E Itis very important to mount the equipment in a suitable cabinet or on a stable surface m Make sure the place has a good ventilation is out of direct sunlight away from sources of excessive dust dirt heat water moisture and vibration Unpacking The equipment comes with the standard parts shown in package content Check and make sure they are included and in good condition If anything is missing or damaged contact the supplier immediately lt Part 1 gt IP S101 lt 1 1 gt Package Contents IP S101 unit X 1 CE 6 6ft Combo KVM cable X 1 Power adapter w power cord for receiver X 1 P 1 lt 1 2 gt Specification USB Mouse KB VGA Front Power Rear O IP S101 Specification IP Connection Console connection PC connection Virtual Media Serial Power Operation Temperature Storage Temperature Humidity Dimension Weight Environmental Virtual KVM PC Media Serial LAN PS 2 Mouse KB 1 x RJ 45 Ethernet 10 100 1 XDB 15 VGA up to 1600 x 1200 2 x USB type connector for keyboard amp mouse 2 x PS 2 mini Din 6 pin for keyboard amp mouse 1 x DB 15 combo KVM port USB type B receptacle 1 x DB9 male 12V power adapter 0 50 C 5 60 C 0 80 Non Condensing 203 5W x 113 3D x 27 3H mm 1 7 kg 3 74 Ib RoHS2 amp R
2. on the equipment s electrical ratings label The voltage rating on the cord should be higher than the one listed on the equipment s ratings label m Observe all precautions and warnings attached to the equipment EH f you don t intend on using the equipment for a long time disconnect it from the power outlet to prevent being damaged by transient over voltage E Keep all liquids away from the equipment to minimize the risk of accidental spillage Liquid spilled on to the power supply or on other hardware may cause damage fire or electrical shock EH Only qualified service personnel should open the chassis Opening it yourself could damage the equipment and invalidate its warranty E If any part of the equipment becomes damaged or stops functioning have it checked by qualified service personnel What the warranty does not cover E Any product on which the serial number has been defaced modified or removed E Damage deterioration or malfunction resulting from O Accident misuse neglect fire water lightning or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product Repair or attempted repair by anyone not authorized by us Any damage of the product due to shipment Removal or installation of the product Causes external to the product such as electric power fluctuation or failure Use of supplies or parts not meeting our specifications Normal wear and tear Any ot
3. 5 255 0 Gateway 9 0 0 0 Wireless LAN Configuration LAN ESSIE Enable WEP encryption New super user password LAN WEP Key a N as New password confirm Status Ready 3 Click Refresh Device to search the connected IP KVM Extender 4 Select the M A C address which you want to setup then click Query Device 5 Enter Super user login The default is super 6 Enter Super user password The default is pass 7 Enter the new super user password 8 Re enter the new password 9 Change the desired IP address Subnet mask Gateway then click Setup Device to confirm the setting to IP KVM Extender 10 The default address is http 192 168 1 22 1 Open Internet Explorer I E version 6 0 or above Authenticate Username and Password 12 Enter the IP KVM Extender address into the address bar For Single IP http 192 168 1 22 Username 13 Enter username default is super Password default is pass Password 14 After successful login to IP KVM Extender the user will enter the main page of IP KVM Extender P 5 The company reserves the right to modify product specifications without prior notice and assumes no responsibility for any error which may appear in this publication All brand names logo and registered trademarks are properties of their respective owners Copyright 2013 Rackmount Solutions Pro com All rights reserved
4. EACH compliant P 2 IP S101 lt Part 2 gt Application IP S101 lt 2 1 gt Connection to KVM console port over IP USB Console piane KVM switch TTY BA CE 6 combo CAT 5 6 cable max 100m Network device lt gt hub or router SQ Re P 3 lt 2 2 gt Connection to computer over IP IP S101 Computer HD CE 6 combo KVM cable P 4 CAT 5 6 cable max 100m Network device hub or router lt Part 3 gt IP Initial setup IP S101 After the cable connection please take the following steps to configure the IP KVM Extender 1 Download IPKVMsetup exe from the link http www rackmount solutions pro com support utilities IPKVMsetup exe 2 Double click IPKVMsetup exe to configure the IP KVM Extender by device setup as below e Device Setup Device Device MAC address C8 EE 08 00 00 7E v Refresh Devices Device Type E C Enable WLAN Configuration WLAN Devices only Authentication Super user login Super user password Network Configuration IP auto configuration None IP address 192 168 1 22 Subnet mask 255 25
5. Solutions Pro User Manual IP S101 Combo KVM Extender m CyberView IP KVM EXTENDER IP S101 REACH Legal Information First English printing October 2002 Information in this document has been carefully checked for accuracy however no guarantee is given to the correctness of the contents The information in this document is subject to change without notice We are not liable for any injury or loss that results from the use of this equipment Safety Instructions Please read all of these instructions carefully before you use the device Save this manual for future reference m Unplug equipment before cleaning Don t use liquid or spray detergent use a moist cloth E Keep equipment away from excessive humidity and heat Preferably keep it in an air conditioned environment with temperatures not exceeding 40 Celsius 104 Fahrenheit m When installing place the equipment on a sturdy level surface to prevent it from accidentally falling and causing damage to other equipment or injury to persons nearby E When the equipment is in an open position do not cover block or in any way obstruct the gap between it and the power supply Proper air convection is necessary to keep it from overheating E Arrange the equipment s power cord in such a way that others won t trip or fall over it MH If you are using a power cord that didn t ship with the equipment ensure that it is rated for the voltage and current labeled
6. her causes which does not relate to a product defect HE Removal installation and set up service charges OOOOO00O Regulatory Notices Federal Communications Commission FCC This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation Any changes or modifications made to this equipment may void the user s authority to operate this equipment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures EH Re position or relocate the receiving antenna E Increase the separation between the equipment and receiver EH Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Contents lt Part 1 gt IP S101 1 1 Package Contents P 1 1 2 Specification P 2 lt Part 2 gt Application 2 1 Connection to KVM console port over IP P 3 2 2

Download Pdf Manuals

image

Related Search

Related Contents

Tripp Lite B020-008 User's Manual  Miele H4680B User's Manual  DEWALT DC390K Use and Care Manual  User Manual  dx4025-dx4030-dx4035 range  Prog_Esecutivo_Generale_2_PSC00  Sony MDR-Q55SL/L  Installation Manual - B&H Photo Video Digital Cameras  

Copyright © All rights reserved.
Failed to retrieve file