Home

GOST Measurement Application (for the FloBoss™ 107) User Manual

image

Contents

1. Enables the use of standard differential pressure transmitters for low and high pressure ranges Valid values are Enabled use stacked DP transmitters or Disabled do not allow use of stacked DP transmitters Sets the parameter for monitoring low differential pressure Click to display a Set TLP dialog box you use to assign the parameter You must Enable the Stacked DP parameter to use this input or you can leave this input in Manual Mode when you Disable Stacked DP Sets the differential pressure point at which the system switches over to the low differential pressure input When the High DP input is active and the High DP reading drops below this value the Low DP input becomes the active input The units are kPa 25 GOST Measurement Application User Manual Field Description High DP Sets the differential pressure point at which the Setpoint system switches over to the high differential pressure input When the Low DP input is active and the Low DP reading rises above this setpoint the High DP input becomes the active input The units are kPa 3 Click Apply to save any changes you have made to this screen 4 Proceed to Section 3 2 5 to define advanced meter parameters 26 Rev Feb 10 GOST Measurement Application User Manual 3 2 3 GOST Flow Setup Advanced tab Use this tab to define advanced meter parameters for the selected meter To access this screen 1 Select the Advanced tab on the GOST Flow Setup sc
2. Entry Pt Displays Status Emp Download User Program File E Program Files gast properties 3 bin Mame GOST Properties Download amp Start Download Version Aew 1 01 Creado 3 32 15 PM 09216 ne 22 E Update Close Figure 11 User Program Administrator 10 Rev Feb 10 GOST Measurement Application User Manual 4 Click Download amp Start to begin loading the selected programs The following message displays Confirm Download 2 J Download amp Start User Program 3 on memory allocations For this reason the GOST Properties program automatically installs as program 3 5 Click Yes to begin the download During the download the program performs a warm start creates an event in the event log and when the download completes displays the following message ROCLINK 800 oe s 1 Download amp Start User Program COMPLETED Figure 13 ROCLINK 800 Download Confirmation 6 Click OK The User Program Administrator screen displays see Figure 14 Note that The User Programs Installed in Device frame identifies the loaded program The Status field indicates that the program is running Rev Feb 10 11 12 G OST Measurement A lication User Manual User Program Administrator User Programe Installed in Device Ma Prograrn Ma Pragram 3 GOST Properties Ma Program GOST Flow Program
3. mam ROCLINK 800 GOST Flow Values File Edit View ROC Configure Meter Utilities Tools Window Help Dw b Oi Mw hi FZOR EY h Point Number 1 GOST 1 GOST Flow Program Status Program Running No Error Meter Tag GOST 1 Meter Description Meter 1 Description Active Flow Calculation AGA7 96 Active Properties Calc GOST VNIC SMV Current Values Calculated Factors Input Values Uncorrected Flow 500 0 km3 D ay Static Pressure f 50 0 kPa Flowing Temperature 50 0 Deg C Instantaneous Rates Flow Rate Energy Rate Mass Rate 46944 02 m3 Hour 481 17620 0 MJ Hour 32424 5 kg Hour 1126 656 km3 Day f 154823 0 GJ Day 778 1 838 Tonnes Day Accumulations km3 GJ Tonnes Minutes Today 0 2216801 227 2221 0 153116 0 2833333 Yesterday oo oo oo joo iQ Month 02208800 aza ois3u6 02833353 Prev Month oo io 00 oo Accumulated 0 2216801 22722202 0 153116 02833333 Save As Auto Scan Figure 28 GOST Flow Values screen 4 Review the values in the following fields Field Description Point Number Selects the specific meter run you want to view Click v to display additional meters for this screen GOST Flow This read only field shows the run status of the Program Status program Valid values are Program Running No Error Program Not Loaded Program Loaded Not Enabled Not Running License Not Found and Not Running Licen
4. 1 1 Scope and Organization This document serves as the user manual for the GOST Measurement Application user program which is intended for use in FloBoss 107 FB107 This manual describes how to download and configure the programs referred to as the GOST programs or the programs throughout the rest of this manual You access and configure the programs using ROCLINK 800 Configuration Software version 1 75 or greater loaded on an IBM compatible personal computer PC running Windows 2000 with Service Pack 2 Windows XP or Windows Vista The sections in this manual provide information in a sequence appropriate for first time users Once you become familiar with the procedures and the software running in a FB107 the manual becomes a reference tool This manual has the following major sections Section I Introduction Section 2 Installation Section 3 Configuration Section 4 Reference This manual assumes that you are familiar with the FB107 and its configuration For more information refer to the FloBoss 107 Flow Manager Instruction Manual Form A6206 or the ROCLINK 800 Configuration Software User Manual for FB107 Form A6217 1 2 Product Overview The GOST Measurement Application consists of two programs GOST Properties and GOST Flow The GOST Properties program enables a FB107 to calculate compressibility using the GOST 30319 96 compressibility standard The GOST Flow pr
5. 247465 Flowing Compressibility 0 9966214 Velocity of Approach no Base Compressibility o 9980378 Ksh Noc 1 Compressibility Coeff no o oo Kp Hc Viscosity loss Ep Kre 1 000217 Isentropic Exponent 1 3 Reynolds Number 00 Heating Value 1025 0 MJ m3 Pipe Diameter Temp joo mm Orifice Diameter amp Temp 0 0 mm Beta Ratio 01 Save s Auto Scan 2 Update Close gt SONSEINES 3304M Figure 50 GOST Flow Values Calculated Facors tab 2 Review the values listed on the screen Note All fields on the Calculated Factors tab are read only 3 Proceed to Section 3 4 to save your configuration 42 Rev Feb 10 GOST Measurement Application User Manual 3 4 Saving the Configuration Whenever you modify or change the configuration save the final configuration to memory To save the configuration 1 Select ROC Flags on the ROCLINK 800 menu bar The Flags screen displays Restart Flash Memory Warm Stark Save Configuration Cold Start Cold Start amp Clear Alarms E vents Status i Cold Start amp Clear Displays Cold Start amp Clear FST Cold Start amp Clear History Cold Start amp Clear ALL 2 Update Y OK S Cancel Figure 31 Flags 2 Click Save Configuration A verification message displays ROCLINK 800 3 Perform Flash Memory Save Configuration Figure 32 Save Verification Rev Feb 10 43 GOST Measure
6. AGAS must be the active properties calculation to view this screen If the GOST Properties program or other properties program is installed and active then properties do not need to be entered on this screen and the following message displays Meter run flows are not being calculated by AGAS 2 Review the values in the following fields Field Description Compositions Sets the mole percent for each gas component The default values are 96 Methane 3 Ethane and 1 Nitrogen Under the system default AGA8 detailed method of properties calculations the value in the Total Mole 96 field must equal 100 after you define or accept the default mole percentages FPV Method Sets the method of determining a compressibility factor for AGA calculations Value values are 30 Rev Feb 10 GOST Measurement Application User Manual Field Description FPV Method Detailed Requires the natural gas composition continued in mole percent to be entered for all components Gross1 Uses the specific gravity of the natural gas the real gas gross heating value per unit volume and the mole 96 of CO2 as the quantity of non hydrocarbon components Gross2 Uses the specific gravity of the natural gas the real gas gross heating value per unit volume and the mole 96 of CO2 and the mole 96 of N2 as the quantity of non hydrocarbon components Note If you choose either Gross1 or Gross2 you must manually enter values for Specific Gravity and
7. Enabled Disabled Calculation Method GOST 585 05 Oen Too Type Corer Awetaging Techrique Integral Muighe Penod f Plow Dependert Linear IMP ho Plow Dependent foenuiac Plow Weighted Linear Flow Algming C Flow Weaghted Formule Enabled Meeter C Disabled Active Nama No Flow Low High Be Severs Ato Scan F Unde Cxe ary Figure 21c GOST Flow Setup General tab Calculation Method is GOST 8 586 05 Rev Feb 10 Be Smeds hasc Dupsse Dom 8 amv xa ROCLINK 800 5e Ed we BOC Confoue Mete ses Toos DG gu ec Point Number 1 GOST 1 GOST Flow Progam Statue Program Running No Emo GOST Plow Setup FB107 window Help Now WP PFROGCPF gov Mete Taz GOST 1 Mete Description Mater it Descrption Active Flow Caleulsten ADASI Active Properties Cale AGASSO Detsiad Gees ingats Advanced Fhad Properties Semler Coltraten Factors Alene GOST Corfgualion GOST Flow Calculation Enabled Ditabled Arraba Setup Serace Type 495 1 CacuweK Enter kK K Value 0 0 Calculation Method nri us Averaging Techrique Integral Mulieher Penod f Plow Dependert Linear IMP ho Plow Dependent F omulac Plow Weighted Linea Flow Algen C Plow Weaghied Foren dec Enabled Mreter Disabled Active Nama No flow High Be Sevens AsoScan upase Coo aov Figure 21b GOST Flow Setup General tab Calculation Me
8. 3 User Program Administrator User Programe Installed in Device Mame No Program Ma Program Ma Prograrn Version Library Version Ma Program Mo Program Created DRAM Used No Program CAC FLASH Used Entry Pt Displays NN LS Ste Status Emp All Option Download User Program File Browse Mame Version Created CRC Size A A A AAAAA Update Close Figure 3 User Program Administrator 4 Click Browse in the Download User Program File frame The Select User Program File screen displays see Figure 4 5 Select the path and user program file to download from the CD ROM Program files are typically located in the Program Files folder on the CD ROM As Figure 4 shows the screen lists all valid user program files with the BIN extension Rev Feb 10 5 G OST Measurement A lication User Manual Select User Program File Look in Z3 Program Files i 4 lj gost properties 3 bin My Recent Documents My Documents qs My Computer File name gost flowcalc 5 bin iu Files of type User Programs bin Cancel Figure 4 Select User Program File 6 Click Open to select the program file The User Program Administrator screen displays As shown in Figure 5 note that the Download User Program File frame identifies the selected program and that the Download
9. Expiration OF 02 2008 02 08 28 PM Connect to KEY Move ta DEVICE Add License Remove Licenses on KEY Vendor ID i Serial Number 2355 53 License Key Event Log eral Number Jobo Figure 2 License Installed Note An FB107 can hold up to six different licenses although you can install only one instance of each license on the FB107 When you click Move to Device ROCLINK 800 moves only one instance of the license onto the FB107 and automatically decreases the license quantity on the USB key by one 5 Verify the license name displays in the Licenses on Device section of the screen Proceed to Section 2 2 to download the user program Rev Feb 10 GOST Measurement Application User Manual 2 2 Downloading the GOST Flow Calculation Program This section provides instructions for installing the GOST Measurement programs into the Flash memory on the FB107 The GOST Measurement Application consists of two program files GOST_FlowCalc_5 bin and GOST_Properties_3 bin The programs may be run separately and are independent of each other This manual assumes you are installing both programs Connect a PC to the FloBoss s LOI port before starting the download To download the user program 1 Start and logon to ROCLINK 800 2 Select ROC Direct Connect to connect to the FloBoss unit 3 Select Utilities User Program Administrator from the ROCLINK menu bar The User Program Administrator screen displays see Figure
10. If Enter is selected set a value for the pressure If entered the value must be greater than zero Gravitational Select Calculate or Enter for the value in m3 sec2 of Acceleration the Gravitational Acceleration for the value at the metering location If Calculate is selected the value is calculated from elevation and latitude If Enter is selected set a value for the acceleration If entered the value must be greater than zero Ref Temp Sets in C the temperature at which the meter tube Pipe inside diameter was measured Rev Feb 10 27 GOST Measurement Application User Manual 28 Field Material Coeff A Pipe Material Coeff B Pipe Material Coeff C Pipe Internal Roughness Pipe Ref Temp Orifice Probe Material Coeff A Orifice Probe Material Coeff B Orifice Probe Material Coeff C Orifice Probe Initial Corner Radius Orifice Probe Inspection Period Orifice Probe Base Pressure Description Sets the pipe material s coefficient of linear expansion for coefficient A Note This number can be found in Appendix C of the GOST 8 563 1 97 user manual Sets the pipe material s coefficient of linear expansion for coefficient B Note This number can be found in Appendix C of the GOST 8 563 1 97 user manual Sets the pipe material s coefficient of linear expansion for coefficient C Note This number can be found in Appendix C of the GOST 8 563 1 97 user manual
11. ROCLINK 800 Configuration Software User Manual for FloBoss 107 Form A6217 1 3 1 License Keys Some applications require that you install a license in the CPU to run the application This license software is specific to these applications and is the property of the individual vendor shown in the Vendor Name field on the License Key Administrator screens RAS and other authorized vendors distributes software licenses on security enhanced universal serial bus USB drives You must install the following license keys to use the Water and Steam Program GOST FlowCalc License Key FSILK 5 GOST Properties License Key FSILK 6 2 Rev Feb 10 GOST Measurement Application User Manual Chapter 2 Installation This section provides instructions for installing the GOST Measurement programs into FBI07 memory Read Section 1 5 of this manual for program requirements Note The program and license key can be installed in any order The manual shows the installation of the license key first 2 1 Installing the License Key A license key is required to use the programs included in the GOST Measurement Application To install a USB key based license on the FB107 1 Insert the USB license key in a USB port on your PC 2 Select Utilities gt License Key Administrator gt Transfer Between Device and Key from the ROCLINK 800 menu bar The Transfer Licenses Between a Device and a Key screen displays Transfer Licenses Be
12. Sets in millimeters the interior wall roughness of the pipe Note The field is only applicable if GOST 8 563 97 Orifice or GOST 8 586 05 Orifice is selected as the Calculation Method Sets in C the temperature at which the Orifice Annubar probe or Venturi tube inside diameter was measured Sets the Orifice Annubar probe or Venturi tube material s coefficient of linear expansion for coefficient A Note This number can be found in Appendix C of the GOST 8 563 1 97 user manual Sets the Orifice Annubar probe or Venturi tube material s coefficient of linear expansion for coefficient B Note This number can be found in Appendix C of the GOST 8 563 1 97 user manual Sets the Orifice Annubar probe or Venturi tube material s coefficient of linear expansion for coefficient C Note This number can be found in Appendix C of the GOST 8 563 1 97 user manual Sets in millimeters the initial orifice corner radius Note The field is only applicable if GOST 8 563 97 Orifice or GOST 8 586 05 Orifice is selected as the Calculation Method Sets in years the orifice inspection period Note The field is only applicable if GOST 8 563 97 Orifice or GOST 8 586 05 Orifice is selected as the Calculation Method Enter the flow measurement Base Pressure in kPa specified in the gas contract Rev Feb 10 GOST Measurement Application User Manual Field Description Base Enter the flow measurement Base Temperature i
13. m3 Hour 481 17620 0 MJ Hour 32424 57 kg Hour f 126 656 km3 Day I 154823 0 GJ Day 778 1 838 Tonnes Day Accumulations km3 GJ Tonnes Minutes Today 0 2216801 227 2221 0 1 53116 0 2833333 Y esterday oo nass oo 8t S lg Month 02206900 aza eae 02803008 Prev Month oo bo x joo oo Accumulated 0 2216801 227 2221 0 153116 0 2833333 Save As Auto Scan Figure 29 GOST Flow Values Current Values tab 5 Review the values listed on the screen Note All fields on the Current Values tab are read only 6 Proceed to Section 3 3 2 to view calculation factors Rev Feb 10 41 GOST Measurement Application User Manual 3 3 2 GOST Flow Values Calculated Factors tab Use this tab to view the values of program calculated factors To access this screen 1 Select the Calculated Factors tab on the GOST Flow Values screen mam ROCLINK 800 GOST Flow Values File Edit View ROC Configure Meter Utilities Tools Window Help D c k gi Wom ht Seo Point Number 1 GOST 1 GOST Flow Program Status Program Running No Error Meter Tag GOST 1 Meter Description Meter 1 Description Active Flow Calculation AGA7 96 Active Properties Calc AGA8 92 Detailed Flow Calculation Factors Fluid Property Factors Upstream Static Pressure 251 325 kPa Flowing Density f 55638 kg m3 Discharge Coefficient loe Base Density 0 6907072 kg m3 Expansion Factor
14. seperc eiee iat neciostax fewest Deos o a bo oaoed sib du c tbo cde diuet i doti i Pid A I iae 1 ALS iProgram Iedilremellls o3 5 9 cond iao io oe tol udtust o etd copa Dave po dott Pee seva poco Orian are 2 US E EIe d cce 2 Chapter 2 Installation 3 2d installing ine bI6ense IO escenes vus dURc devote Minute r a a loros uc dui imd 3 2 2 Downloading the GOST Flow Calculation Program sees 5 2 3 Downloading the GOST Properties Program ssseeeesseesseeeeeeeee nennen 9 Chapter 3 Configuration 13 3 1 GOST Properties SOFGe Iiusisionieen diede otto debe putem idest tus feme ticbot Lentulus ie mis Me d LSU uus 14 3 1 1 GOST Properties Settings tab eeesssssssessssessseeseennn nennen nnne nnns 15 3 1 2 GOST Properties Gas Quality taD rssi e a A E nnns 16 3 1 3 GOST Properties Calculated Values tab ccccccccsssseeeeeeeeseeeeeeeeeeeeesseeeseeeeeeessaaaaeees 18 Sc GOST FIOW Selup SCIOBIus d ibo it iori Dieu omae tmntdcost ides eins eee 19 3 2 1 GOST Flow Setup General tab sessi nennen nennen nnns 21 3 2 2 GOST FIOW Setup IMDUTS tab iode obedece eode sos et asevas eu uitae oe m ee sedit c duds 24 3 2 3 GOST Flow Setup Advanced tab cc ccccssccececcesscccesseeeeeeecescceseeeeeesscaceseeseeeenessceesens 27 3 2 4 GOST Flow Setup Fluid Properties tab cccccccccccssssseeceeeeeeeeeeseseeeeesseeeseeeeeeeeessaeageee
15. 288803 Viscosity fa 0119367 cP Speed of Sound 456 1617 m s Superior Heating Value 37 5057 MJ m3 Inferior Heating Value 33 81 63 MJ m3 Save As Auto Scan 2 Update Close gt JONGEINES 2124M Figure 19 GOST Properties Calculated Values tab 2 Review the values listed on the screen Note All fields on the Calculated Values tab are read only 3 Proceed to Section 3 2 to define the GOST Flow Setup screen 18 Rev Feb 10 GOST Measurement Application User Manual 3 2 GOST Flow Setup Screen Use this screen and its tabs to define the calculation method used by the program To access this screen 1 From the Directory Tree select User Program GOST Flow Program 2 Double click Display 32 GOST Flow Setup Double click 1 GOST 1 The GOST Flow Setup screen displays showing the General tab mam ROCLINK 800 GOST Flow Setup FB107 File Edit View ROC Configure Meter Utilities Tools Window Help Do kd Gt Wm ht oe Ole E h Point Number 1 GOsT i vj GOST Flow Program Status Program Running No Error Meter Tag GOST S1 Meter Description Meter 1 Description Active Flow Calculation GOST 8 563 97 Active Properties Calc AGAS 32 Detailed General Inputs Advanced Fluid Properties Sampler Calibration Factors Alarms GOST Configuration GOST Flow Calculation C Enabled Disabled Calculation Method GOST 8 563 97
16. 66 Kg m3 i Pentane f CO Hexane fo 0 Hydrogen Heptane fo 0 Total Save As Auto Scan 2 Update Close TONEDINE 3 03 4m Figure 16 GOST Properties Gas Quality tab 2 Review the values in the following fields Field Description Component 96 Enter the mole percent of each gas component The Mole Total Mole should equal 100 after all the component mole percentages have been entered Notes For VNIC SMV calculations all mole 96 fields must be entered For GERG 91 and NX19 calculations only CO2 Nitrogen and Base Density need to be entered Heating Values Sets how the system determines the heating value for a specified quantity of gas Valid values are Calculate allow the system to calculate the heating value from the gas composition data or Enter use the value specified in the energy calculation 16 Rev Feb 10 GOST Measurement Application User Manual Field Description Inferior Heating Sets displays in MJ m3 the inferior heating value Value based on the Monitor Heating Value selection If the Heating Values field is set to Calculate this read only field shows the inferior heating value calculated by the program If the Heating Values field is set to Enter sets a user defined inferior heating value Superior Heating Sets displays in MJ m3 the superior heating value Value based on the Monitor Heating Value selection If the Heating Values field is set to Calculate this r
17. Form A6262 Part Number D301591X012 February 2010 GOST Measurement Application for the FloBoss 107 User Manual Remote Automation Solutions ex EMERSON GOST Measurement Application User Manual Revision Tracking Sheet February 2010 This manual may be revised periodically to incorporate new or updated information The revision date of each page appears at the bottom of the page opposite the page number A change in revision date to any page also changes the date of the manual that appears on the front cover Listed below is the revision date of each page if applicable Page Revision All pages Feb 10 Initial Issue Aug 08 NOTICE Remote Automation Solutions RAS division of Emerson Process Management shall not be liable for technical or editorial errors in this manual or omissions from this manual RAS MAKES NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THIS MANUAL AND IN NO EVENT SHALL RAS BE LIABLE FOR ANY INCIDENTAL PUNITIVE SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF PRODUCTION LOSS OF PROFITS LOSS OF REVENUE OR USE AND COSTS INCURRED INCLUDING WITHOUT LIMITATION FOR CAPITAL FUEL AND POWER AND CLAIMS OF THIRD PARTIES Bristol Inc Bristol Canada BBI SA de CV and Emerson Process Management Ltd Remote Automation Solutions division UK are wholly owned subsidiaries of Emerson E
18. Heating Value on this screen Gross2 requires a value for Heating Value only for calculating the gas energy flow While the Detailed method provides the highest accuracy in a broad range of measurement conditions you can use either of the Gross methods when Temperature is between 0 C and 54 C Pressure is between 0 and 8274 kPa Gas composition is within the Normal range as defined in the 1992 AGAS report Heating value Sets how the system determines the heating value for a specified quantity of gas Valid values are Calculate allow the system to calculate the heating value from the gas composition data or Enter use the value specified in the energy calculation Heating Value Identifies the property basis the system used to Basis determine the heating value for the flow or energy calculations Valid values are Dry No water vapor present in gas Wet Saturated wator vapor present in gas Note When you select this option the FB107 calculates the mole percentage of water based on the algorithm from IAPWS IF97 standards and adjusts the other mole percentages accordingly Hev Feb 10 31 GOST Measurement Application User Manual Field Description Specific Gravity Sets the ratio of the molar mass of the gas to the molar mass of the air a value used in the flow calculation Valid values are Calculate the system calculates the value and Enter use the specific value for the flow calculation Note If you se
19. Ma Program Clear Start Download User Pragram File Stop Mame Version Created CHC Entry Pt Displays Hev 1 01 OF 09 2008 15 42 15 On9216 Ox5CO000 29 Library Version Rev O DRAM Used 15384 FLASH Used 52722 Status Running E Proaram Filessgast properties 3 bin Browse Download amp Start Download Name GOST Properties Rew 1 01 79 2008 3 42 15 PM 0 3216 ner 22 Version Created CALC Size Figure 14 User Program Administrator 7 Click Close and proceed to Section 3 to configure the program Rev Feb 10 GOST Measurement Application User Manual Chapter 3 Configuration After you have loaded the GOST Measurement Application you configure it using the ROCLINK 800 software To do this you use one GOST Properties screen GOST Properties and two GOST Flow Calculations screens GOST Flow Setup and GOST Flow Values Use the GOST Properties screen to define program specifics including calculation method and gas composition Use the GOST Flow Setup screen to define meter properties Use the GOST Flow Values screen to view flow totals and alarms mam ROCLINK 800 On Line Com1 FB107 Eile Edit View ROC Configure Meter Utilities Tools Window Help Da teel alt eS When VMRISZORBlA Rl w SM N On Line Com FB107 FEE rZ s Inl Modules Se 1 0 amp Control H a Meter System History El User Program Administrator i
20. Orifice Tap Type Corner Y Meter run flows are not being calculated by the GOST flow program Use Meter Setup screen i Saves Auto Scan Update Close b DENE 321 M Figure 20 GOST Flow Setup screen 4 Review the values in the following fields Field Description Point Number Selects the specific meter run you want to define Click v to display all meters in the device GOST Flow This read only field shows the run status of the Program Status program Valid values are Program Running No Error Program Not Loaded Program Loaded Not Enabled Not Running License Not Found and Not Running License Expired Rev Feb 10 19 GOST Measurement Application User Manual Field Description Meter Tag Sets a name up to 10 alphanumeric characters for the selected meter run Note The program uses this description on subsequent program screens Meter Sets a short description up to 20 alohanumeric Description characters for the selected meter run Note The program uses this description on subsequent program screens Active Flow This read only field indicates the specific flow Calculation calculation in use Active This read only field indicates the specific properties Properties Calc calculation in use a tab format Sections 3 2 1 through Section 3 2 7 discuss the requirements for each tab on the GOST Flow Setup screen 20 Rev Feb 10 GOST Measurement Application User Manual 3 2 1 GOST Flow Set
21. S GOST Properties E8 Display 29 GOST Properties GOST Flow Program E Display 32 GOST Flow Setup EH Display 33 GOST Flow Values User Display General n Setup 1 0 Points Installed Module OnBoard Poit Actual Module On Board 6 Point 10 Description CPU Field Interface Revision Re 1 01 Part Number went Build Date Sep 18 2007 9 06 Serial Number w48084X00124 07370028 Boot Revision Rev 1 01 Boot Build Date Sep 18 2007 9 06 Integrity Uninstall Auto Scan Update Figure 15 ROCLINK 800 screen Rev Feb 10 13 GOST Measurement Application User Manual 3 1 GOST Properties Screen Use this screen and its tabs to define the fluid properties calculation method and gas composition To access this screen 1 From the Directory Tree select User Program GOST Properties 2 Double click Display 29 GOST Properties 3 Double click 1 MET01 The GOST Properties screen displays showing the Settings tab mam ROCLINK 800 GOST Properties File Edit view ROC Configure Meter Utilities Tools Window Help D g W gi MUS Vm See E kh Point Number 1 MET UI Active Flow Calc AGA7 96 Active Properties Calc AGA8 92 Detailed Settings Gas Quality Calculated Values GOST Properties Calculation Calculation Standard V T Disabled m Save As Auto Scan Update Close Apply gt ON LINE 9 02 4M Figure 16 GOST Properties scre
22. alled in Device frame identifies the loaded program The Status field indicates that the program is running Rev Feb 10 7 GOST Measurement Application User Manual User Program Administrator User Programe Installed in Device Ma Program Mame GOST Flow Program Ma Program Ma Prograrn Version Rew 1 20 Library Version Rew O Ma Program E TETTE GERIT EN Created 02 15 2010 11 20 07 DRAM Used 16384 No Program CAC OsfE10 FLASH Used 56138 Entry Pt Ox5 0000 Displays 32 33 Cm 2 Status Running All Option Download User Program File E Program Files gost_flowealc_5 bin Browse Mame GOST Flow Program Download amp Start Download Version Rev 1 20 Created 2 15 2010 11 20 07 AM CAC Ox E10 SIZE 55138 Figure 6 User Program Administrator 10 Proceed to Section 2 5 to load the GOST Properties program Rev Feb 10 GOST Measurement Application User Manual 2 3 Downloading the GOST Properties Program This section provides instructions for installing the GOST Properties program into the Flash memory on the FB107 To download the user program User Program Administrator User Programs Installed in Device No Program Mame GOST Flow Pragram Ma Prograrn Ma Prograrn Version Aew 1 01 Library version Rev O Ae E Created 07 25 2008 13 22 19 DRAM Used 16384 GOST Flow Program Ma Pragram CAL s P46 FLASH Used 54 60 Entry Pt Ox5 0000 Display
23. amp Start button is active User Program Administrator Eg User Programe Installed in Device 1 No Program Mame No Program 2 Ma Program 3 Ma Fragram Version Library Version 4 Ma Program Created DRAM Used D B No Program CALC O40 FLASH Used Entry Pt Displays NN _Stat_ Ste Status Emp All Option Download User Pragram File E SFrogram Files gost_flowealc_5 bin Name GOST Flow Program Download amp Start Download Version Rev 1 20 PAUTO 11 20 07 AM 0s7E10 56138 n Figure 5 User Program Administrator Rev Feb 10 GOST Measurement Application User Manual 7 Click Download amp Start to begin loading the selected programs The following message displays Confirm Download J Download amp Start User Program 5 Figure 6 Confirm Download Note For the FB107 the factory has assigned program positions based on memory allocations For this reason the GOST Flow Calculation program automatically installs as program 5 8 Click Yes to begin the download During the download the program performs a warm start creates an event in the event log and when the download completes displays the following message ROCLINK 800 Wo 1 Download amp Start User Program COMPLETED Figure 7 ROCLINK 800 Download Confirmation 9 Click OK The User Program Administrator screen displays see Figure 8 Note that The User Programs Inst
24. c Length Range Default Description of functionality and meaning of values 0 Point Tag ID R W String 10 0x20 0x7E for E Point Type Description each ASCII character 1 Calculation Standard R W UINT8 1 0 1 2 0 opecifies the properties calculation to be used by the program 0 VNIC SMV Properties Calculation 1 GERG 91 Properties Calculation 2 NX19 Properties Calculation 2 Base Density R W Float 4 Any IEEE float value 0 666 Shows calculated base density in kg m3 when VNIC calculation is selected Allows user to enter base density value in kg m3 when GERG or NX19 calculation is selected 3 Calculate Enter Heating Value R W UINT8 1 0 1 1 Specifies if program should calculate heating value 0 User enters heating value 1 Program calculates heating value 4 Monitor Heating Value Option R W UINT8 1 0 1 1 Specifies which heating value should be used for energy calculations and archival 0 Use inferior heating value 1 Use superior heating value 5 GOST Calc Enable R W UINT8 1 0 1 0 Specifies if the GOST program should calculate fluid properties 0 Do not calculate fluid properties for meter run 1 Calculate properties based selected GOST standard 6 Superior Heating Value R W Float 4 Any IEEE float value 0 0 Shows calculated superior heating value in MJ m3 when user has selected calculate heating value option Allows user to enter the superior heating value in MJ m3 when user has selected enter heating value optio
25. cription Active Flow Calculation GOST 8 563 97 Active Properties Calc AGA8 92 Detailed 170 Definition Values Differential Pressure AIN AS EU El f 00 0 kPa Static Pressure AIN A10 EU En 75 0 kPa Temperature AIN A3 EU Eu 50 0 DegC Pipe Diameter 1 00 0 millimeters Orifice Diameter 1 4 39038 millimeters Low Flow CufOff 0 1 kPa Stacked DP Enable Low DP Input Manual E f Disable LowDPSetpont 00 kPa High DP Setpoint 0 0 kPa Piw Save As Auto Scan 2 Update Close TONSEINES 3184M Figure 22 GOST Flow Setup Inputs tab 2 Review the values in the following fields Field Description Differential Sets the input that senses the differential pressure Pressure Assigns the point type logical and parameter TLP of the I O value for the static pressure Click to display the Select TLP screen and define your TLP selection The value field shows in kPa the differential pressure If Manual appears use the Values field to enter an engineering units value for the meter input Otherwise the Values field indicates the current input value 24 Rev Feb 10 GOST Measurement Application User Manual Rev Feb 10 Field Static Pressure Temperature Orifice Probe Tube Diameter Low Flow CutOff Low DP Input Low DP Setpoint Description Sets the input that senses static pressure Assigns the point type logical and parameter TLP of the I O value for the static pres
26. ead only field shows the superior heating value calculated by the program If the Heating Values field is set to Enter sets a user defined superior heating value Monitor Heating Sets which heating value is used for energy Value calculations and archives Valid selections are Inferior and Superior Base Density Sets displays in kg m3 the density of the selected product at base conditions For VNIC SMV this read only field shows the program calculated base density For GERG and NX19 sets a user defined base density 3 Click Apply to save any changes you have made to this screen 4 Proceed to Section 3 1 3 to review calculated values Hev Feb 10 17 GOST Measurement Application User Manual 3 1 3 GOST Properties Calculated Values tab Use this tab to view all property values calculated by the program To access this screen 1 Select the Calculated Values tab on the GOST Properties screen vam ROCLINK 800 GOST Properties Eile Edit View ROC Configure Meter Utilities Tools Window Help D c E giu HU he Hh oo 4 Ol amp ED 2 hk Point Number f METO1 Active Flow Calc AGA7 96 Active Properties Calc GOST VNIC SMV Compressibility at Flowing Conditions 0 996521 g Compressibility at Base Conditions 0 9980009 Compressibility Coefficient 0 99851 8 Density at Flowing Conditions 1 556624 Kg m3 Density at Base Conditions 0 6907708 Kg m3 Molecular Weight E 6 58352 Isentropic Exponent f
27. ear expansion for coefficient A coefficient B Pipe material s coefficient of linear expansion for coefficient C Orifice Annubar probe or Venturi tube material s coefficient of linear expansion for coefficient A Orifice Annubar probe or Venturi tube material s coefficient of linear expansion for coefficient B Rev Feb 10 GOST Measurement Application User Manual Point Type 31 GOST Flow Setup iu Name Access ced Length Range Default Description of functionality and meaning of values 11 Orifice Material C Coefficient R W Float 4 Any IEEE float value 6 0 Orifice Annubar probe or Venturi tube material s coefficient of linear expansion for coefficient C 12 Annubar Sensor Model R W UINT8 1 027 0 Specifies model of Annubar sensor in use 0 Annubar 485 Model 1 1 Annubar 485 Model 2 2 Annubar 485 Model 3 3 Annubar Diamond II Model 10 4 Annubar Diamond II Model 15 16 5 Annubar Diamond II Model 25 26 6 Annubar Diamond II Model 35 36 7 Annubar Diamond II Model 45 46 13 Calculate K Option R W UINT8 1 0 1 0 Specifies if the Annubar Flow Coefficient K is calculated by the program or entered by the user 0 Calculated by program 1 Entered by user 14 Annubar Flow Coefficient K R W Float 4 Any Positive Floating 0 0 Annubar Flow Coefficient value used in flow equation Point Number This value is calculated by the program when the calculate K option is selected The user must enter thi
28. en 4 Review the values in the following fields Field Description Point Number Indicates the specific meter run you want to define Click to display additional runs for this device Active Flow This read only field indicates the specific flow Calc calculation in use Active This read only field indicates the specific Properties Calc properties calculation in use Note The GOST Properties screen like other screens in this program has a tab format Sections 3 1 1 through 3 1 3 discuss the requirements for each tab on the GOST Properties screen 14 Rev Feb 10 GOST Measurement Application User Manual 3 1 1 GOST Properties Settings tab Use this tab which displays when you access the GOST Properties screen to define the fluid properties calculation method used by the program and program options vam ROCLINK 800 GOST Properties File Edit view ROC Configure Meter Utilities Tools Window Help D cv bd gi Mw V mOTSOoOENEN E kh Point Number 11 METOT v Active Flow Calc AGA 96 Active Properties Calc AGA8 92 Detailed Settings Gas Quality Calculated Values GOST Properties Calculation Calculation Standard Disabled pad El Save As Auto Scan 2 Update Close Apply gt IGNSEINES 502M Figure 17 GOST Properties Settings tab 1 Review the values in the following fields Field Description GOST Sets the run status for GOST properties Properties calculations Val
29. ethod for the selected meter run Valid values are GOST 8 563 97 Orifice GOST 8 586 05 Orifice Annubar and Venturi Sets the tapping type Valid values are Corner Flange and Pipe D and D 2 Note The field displays only if GOST 8 563 97 Orifice or GOST 8 586 05 Orifice is selected as the Calculation Method Sets the Venturi tube type for the selected meter run Valid values are Cast Untreated Machined Treated and Welded Rough Note The field displays only if Venturi is selected as the Calculation Method Sets the type of Annubar sensor for the selected meter run Valid selections are 485 1 485 2 485 3 Diamond 10 Diamond 15 16 Diamond 25 26 Diamond 35 36 and Diamond 45 46 Note The field displays only if Annubar is selected as the Calculation Method Sets whether the Annubar K Factor is a user entered value or is calculated by the program Note The field displays only if Annubar is selected as the Calculation Method Set displays the Annubar sensor K Value If Calculate K is selected this read only field displays the K Value as calculated by the program It Enter K is selected sets a user defined K Value Note The field displays only if Annubar is selected as the Calculation Method Select an Averaging Technique for the Meter Run The default value is Flow Dependent Linear Flow This is the simplest and most Dependant commonly used method This method Linear discards samples for periods
30. his screen 4 Proceed to Section 3 2 4 to configure fluid properties Rev Feb 10 29 GOST Measurement Application User Manual 3 2 4 GOST Flow Setup Fluid Properties tab Use this tab to define fluid properties for the selected meter run To access this screen 1 Select the Fluid Properties tab on the GOST Flow Setup screen mam ROCLINK 800 GOST Flow Setup FB107 File Edit View ROC Configure Meter Utilities Tools Window Help D c kl gi Ww ht SeORR HE Point Number 1 GOST 1 GOST Flow Program Status Program Running No Error Meter Tag GOST 1 Meter Description Meter tt1 Description Active Flow Calculation GOST 8 563 97 Active Properties Calc AGA8 92 Detailed Compositions FP Method Nitrogen 1 0 Heptane 0 0 Detailed Gross Gross2 coz 0 0 Octane 0 0 Healing Valin Methane 96 0 Nonane 0 0 f Calculate Enter Ethane 3 0 Decane 10 0 1025 0 MJ M3 Propane 0 0 H25 10 0 Heating Value Basis n Butane 0 0 Water 0 0 Dy C Wet AsDelivered i Butane 0 0 Helium 0 0 4 Specific Gravity n Pentane 0 0 Oxygen 0 0 C Calculate Enter iPentane 0 0 CO 0 0 0 68 Hexane 0 0 Hydrogen 0 0 Argon 0 0 Viscosity 0 68 Cp Total Mole 100 Sp Heat Ratio 1 3 Log Methane Adjust Gas Quality Enabled C Disabled Constant C Live Pie Save As Auto Scan 2 Update Close b TONSEINES 9184M Figure 24 GOST Flow Setup Fluid Properties tab Note
31. id selection are Enabled and Calculation Disabled If Enabled the program calculates fluid properties based on the calculation specified in the Calculation Standard field for the selected meter run If Disabled fluid properties are calculated by the AGA8 algorithm embedded in FB107 firmware or by a separate properties user program Calculation Set the method of calculation for the selected Standard meter Valid values are VNIC SMV GERG 91 and NX19 2 Click Apply to save any changes you have made to this screen 3 Proceed to Section 3 1 2 to define gas qualities Rev Feb 10 15 GOST Measurement Application User Manual 3 1 2 GOST Properties Gas Quality tab Use this tab to define the fluid properties to be used in the calculation To access this screen 1 Select the Gas Quality tab on the GOST Properties screen nas ROCLINK 800 GOST Properties Eile Edit View ROC Configure Meter Utilities Tools Window Help D c ld gi A in ih Ht S amp 24e oe m ow Point Number 11 METUIT Active Flow Calc AGA7 96 Active Properties Calc GOST VNIC SMY Settings Gas Quality Calculated Values Composition mole Heating Values Nitrogen Octane Calculate Enter c02 b Nonane i Inferior Heating Value 0 0 MJ m3 Methane Decane Superior Heating Value f MJ m3 Ethane H25 Monitor Heating Value Propane Water E Superior n Butane f Helium i Butane Oxygen Base Density n Pentane 10 Argon 0 6
32. ing 10 0x20 0x7E for CRC of GOST properties user program binary image each ASCII character loaded in unit shown in hexadecimal format Rev Feb 10 47 GOST Measurement Application User Manual 4 2 Point Type 31 GOST Flow Setup Point type 31 contains the parameters for configuring the GOST Flow Calculation program The program maintains up to four logicals of this point Point Type 31 GOST Flow Setup Name Point Tag ID Calculation Method Tap Type Access R W R W R W Oo a C 48 Orifice Material B Coefficient R W R W R W R W R W R W Data Type String UINT8 Length Range 10 0x20 OxT7E for each ASCII character 1 0 1 2 UINT8 1 0 10 4 Any IEEE float value Any IEEE float value 4 Any IEEE float value 4 Any IEEE float value 4 Any IEEE float value 4 Any IEEE float value Default Any IEEE float value 6 0 9 4 7 4 Description of functionality and meaning of values Point Type Description Specifies the flow calculation to be used by the program 0 GOST 8 563 97 Orifice Flow Calculation 1 Annubar Flow Calculation 2 GOST 8 586 05 Orifice Flow Calculation 3 Venturi 8 586 04 05 Venturi Tube Calculation Specifies type of pressure tap in use 0 Corner 1 Flange 2 Pipe Inspection period in years Orifice corner radius in millimeters Interior pipe wall roughness in millimeters Pipe material s coefficient of lin
33. lect Enter the value should represent the gas at standard conditions and cannot be less that 0 07 Viscosity Sets the dynamic viscosity of the flowing gas Units are cP Sp Heat Ratio Sets the specific heat ratio of the gas defined as the specific heat of the gas at constant pressure divided by the specific heat of the gas at constant volume Accepted practice for natural gas applications is to use a value of 1 3 which was used to develop the expansion factor tables in the AGA 3 Report Part 3 If entered the value must be greater than zero Log Methane Logs automatic system adjustments to methane Adjust percentages Valid values are Enabled log adjustments or Disabled allow adjustments but do not log them Gas Quality Sets the source for determining gas quality readings Valid values are Constant changes are entered in the event log or Live readings come from a gas chromatograph or are periodically downloaded from a host and are not entered in the event log 3 Proceed to Section 3 2 5 to define sampler operation 32 Rev Feb 10 GOST Measurement Application User Manual 3 2 5 GOST Flow Setup Sampler tab Use this tab to define operation of a sampler To access this screen 1 Select the Sampler tab on the GOST Flow Setup screen xem ROCLINK 800 GOST Flow Setup FB107 File Edit View ROC Configure Meter Utilities Tools Window Help D c kd gi Wie he A OBS E h Point Number 1 GOsT i GOST Fl
34. lectric Co doing business as Remote Automation Solutions RAS a division of Emerson Process Management FloBoss ROCLINK Bristol Bristol Babcock ControlWave TeleFlow and Helicoid are trademarks of RAS AMS PlantWeb and the PlantWeb logo are marks of Emerson Electric Co The Emerson logo is a trademark and service mark of the Emerson Electric Co All other trademarks are property of their respective owners The contents of this publication are presented for informational purposes only While every effort has been made to ensure informational accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability RAS reserves the right to modify or improve the designs or specifications of such products at any time without notice All sales are governed by RAS terms and conditions which are available upon request RAS does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any RAS product remains solely with the purchaser and end user 2008 2010 Remote Automation Solutions division of Emerson Process Management All rights reserved li Hev Feb 10 GOST Measurement Application User Manual Page Chapter 1 Introduction 1 sll SCOPES ANGI OIG ANIZ AVON sie Slee ecu eode succedere alge ceria do ia aa ce uo Bn edo oa od ce e atus 1 12 Product OVEIVICW
35. ment Application User Manual 3 Click Yes When the save process completes a confirmation message displays ROCLINK 800 Figure 33 Confirmation Note Depending on the size and complexity of the user program this process may take several minutes When the process ends the Status field on the Flags screen displays Completed 4 Click Update on the Flags screen This completes the process of saving your new configuration Note For archive purposes you should also save this configuration to your PC s hard drive or a removable media such as a diskette or a flash drive using the File Save Configuration option on the ROCLINK 800 menu bar 44 Rev Feb 10 GOST Measurement Application User Manual Chapter 4 Reference This section provides tables of information on the user defined point types the GOST Measurement Application uses GOST Properties Point Type 28 GOST Properties Configuration and Calculated Values GOST Flow Calculations Point Type 31 GOST Flow Setup Point Type 32 GOST Flow Values Rev Feb 10 45 GOST Measurement Application User Manual 4 1 Point Type 28 GOST Properties Configuration and Calculated Values Point type 28 contains the parameters for configuring the GOST Properties calculation program and viewing calculated property values The program maintains up to four logicals of this point Point Type 28 GOST Properties Configuration and Calculated Values S Name Access u
36. meter run CRC of the GOST flow calculation user program binary image loaded in unit shown in hexadecimal format Specifies the Venturi tube type 0 Cast Untreated 1 Machined Treated 2 Welded Rough Rev Feb 10 GOST Measurement Application User Manual 4 3 Point Type 32 GOST Flow Values Point type 32 1s required for ROCLINK to properly display the meter tag for each meter run when accessing the GOST Flow Values display Point Type 32 GOST Flow Values n Name Access na Length Range Default Description of functionality and meaning of values 0 Point Tag ID R O String 10 0x20 0x7E for i Point Type Description each ASCII character Rev Feb 10 51 GOST Measurement Application User Manual If you have comments or questions regarding this manual please direct them to your local sales representative or contact Emerson Process Management i Remote Automation Solutions S Marshalltown lowa 50158 USA Houston TX 77065 USA Al Pickering North Yorkshire UK Y018 7JA EM ERSON Website www EmersonProcess com Remote
37. n 46 Rev Feb 10 GOST Measurement Application User Manual Point Type 28 GOST Properties Configuration and Calculated Values Eu Name Access uc Length Range Default Description of functionality and meaning of values 7 Inferior Heating Value R W Float 4 Any IEEE float value 0 0 Shows calculated inferior heating value in MJ m3 when user has selected calculate heating value option Allows user to enter the inferior heating value in MJ m3 when user has selected enter heating value option 8 Flowing Compressibility R O Float 4 Any IEEE float value 0 0 Shows the calculated gas compressibility value at flowing conditions Zf 9 Base Compressibility R O Float 4 Any IEEE float value 0 0 Shows the calculated gas compressibility value at base conditions Zb 10 Compressibility Coefficient R O Float 4 Any IEEE float value 0 0 Shows the value of compressibility coefficient Zf Zb 11 Flowing Density R O Float 4 Any IEEE float value 0 0 Shows the calculated gas density at flowing conditions in kg m3 12 Viscosity R O Float 4 Any IEEE float value 0 0 Shows the calculated gas viscosity in centipoise cP 13 Isentropic Exponent R O Float 4 Any IEEE float value 0 0 Shows the calculated isentropic exponent 14 Speed of Sound R O Float 4 Any IEEE float value 0 0 Shows the calculated speed of sound in m sec 15 Molecular Weight R O Float 4 Any IEEE float value 0 0 Shows the calculated molecular weight of the gas 16 User Program CRC R O Str
38. n C Temperature specified in the gas contract Elevation Sets the elevation of the metering location expressed in meters This value is required for the calculation of atmospheric pressure and gravitational acceleration Latitude Sets the geographical location for the metering location expressed as degrees and minutes separated by a decimal point such as 46 15 for 46 minutes and 15 degrees Force Forces after you select this value and click Apply Recalculation the system to fully recalculate the flow without waiting for the next normal recalculation You set normal recalculation periods using the Integral Multiplier Period field on the General tab of the GOST Flow Setup screen Note The system automatically resets this parameter to Clear after the recalculation completes Pressure Tap Select the Pressure Tap type and location used in this Meter Run Gauge or Select either Gauge or Absolute as Absolute the pressure tap type This choice must match the static pressure type actually measured by the sensor The MVS sensor DVS sensor or other pressure transmitter can be ordered to provide either absolute or gauge measurements The default value is Gauge Upstream or Select either Upstream or Downstream Downstream to indicate the location of the static pressure tap in relation to the orifice plate or Annubar element during normal flow The default value is Upstream 3 Click Apply to save any changes you have made to t
39. o correct the calibrations to the local gravitational force Note When a dead weight calibrator is used for the differential pressure and the static pressure both must be corrected for local gravity This involves using Fpwl twice WWW WWW WWW WWW WR E Rev Feb 10 35 GOST Measurement Application User Manual Field Description Diff Press Sets whether any corrections occur for local gravity s effects on dead weight calibrations to differential pressure Note he system uses the factor Fpwl to correct for the effect of local gravity on the weights of a dead weight calibrator which are usually sized for use at a standard gravitational force or at some specified gravitational force A correction factor must then be applied to correct the calibrations to the local gravitational force When a dead weight calibrator is used for the differential pressure and the static pressure both must be corrected for local gravity This involves using Fpwl twice Calibrated Grav Enter a value in this field if the gravitational Accel acceleration at the site where the deadweights were calibrated is different from the value indicated The units assumed for the input are m Sec 3 Proceed to Section 3 2 7 to define alarm conditions 36 Rev Feb 10 GOST Measurement Application User Manual 3 2 GOST Flow Setup Alarms tab Use this tab to define alarm conditions for the program To access this screen 1 Select the Alarms tab on
40. oceed to Section 3 2 6 to define calibration factors 34 Rev Feb 10 GOST Measurement Application User Manual 3 2 6 GOST Flow Setup Calibration Factors tab Use this tab to define calibration factors To access this screen 1 Select the Calibration Factors tab on the GOST Flow Setup screen mam ROCLINK 800 GOST Flow Setup FB107 File Edit View ROC Configure Meter Utilities Tools Window Help D c bd gu Mw Wet os 4 oe E J Point Number 1 GOST 1 GOST Flow Program Status Program Running No Error Meter Tag GOST 1 Meter Description Meter 1 Description Active Flow Calculation GOST 8 563 97 Active Properties Calc AGA8 92 Detailed Dead Weight Calibration Static Press Diff Press e Mo e Mo C Yes C Yes Calibrated Gray Accel 32 14398 M Sec2 Pin Save As Auto Scan 2 Update Close b TONSEINES 3174M Figure 26 GOST Flow Setup Calibration Factors tab 2 Review the values in the following fields Field Description Static Press Sets whether any corrections occur for local gravity s effects on dead weight calibrations to static pressure The system multiplies the factor Fpwl by the base volume flow equation The system uses the factor Fpwl to correct for the effect of local gravity on the weights of a dead weight calibrator which are usually sized for use at a standard gravitational force or at some specified gravitational force A correction factor must then be applied t
41. ogram enables a FB107 to calculate differential flow rates according to the GOST 8563 GOST 8586 Annubar and Venturi standards The GOST Properties program supports a choice of three algorithms for calculating compressibility VNIC SMV for natural gas density 0 668 to 1 00 kg m GERG 91 for hydrogen sulfide free gas density 0 668 to 0 70 kg m NX19 for natural gas density 0 668 to 0 70 kg m Rev Feb 10 1 GOST Measurement Application User Manual VNIC requires the full gas composition NX19 and GERG 91 require N2 CO2 and density at contract conditions Refer to GOST 30319 1 GOST 30319 2 and GOST 30319 5 for specific details on the compressibility calculations and equations The GOST Flow program supports a choice of four algorithms for calculating flow rate Annubar GOST 8 586 05 GOST 8 563 97 Venturi 8 586 04 05 1 3 Program Requirements The GOST Measurement Application version 1 01 1s compatible with FB107 firmware version 1 10 and with version 1 75 or greater of ROCLINK 800 software Each program requires you to install a software based license key to enable the calculations The downloadable program 1s Program User Defined Display preme Number Points Number gost flowcalc 5 bin 5 31 32 32 33 gost properties 3 bin 3 28 29 Note You must connect a PC to the FB107 s LOI port before starting the download For information on viewing the memory allocation of user programs refer to
42. ow Program Status Program Running No Error Meter Tag GOST 1 Meter Description Meter 1 Description Active Flow Calculation GOST 8 563 97 Active Properties Calc AGAS 92 Detailed Sampler Control C Enabled Disabled Output Point Undefined Eg Sampler Accum 1000 0 m3 Sampler Duration 1 0 Seconds Pin Save As Auto Scan 2 Update Close b GRANE 3174M Figure 25 GOST Flow Setup Sampler tab 2 Review the values in the following fields Field Description Sampler Control Allows the sampler to override the DO located on the CPU I O assembly or on an I O module Valid values are Enabled override CPU based I O or Disabled do not control output point The default is Disabled Output Point Sets the DO point to be used Click to display a Select TLP dialog box you use to define the point Sampler Accum Sets the volume of gas to be metered between pulses expressed either in cubic meters For example if an odorizer needs to track every 100 cubic meters of gas being metered enter 100 The Sampler Volume Accum value is based upon the instantaneous flowrate Rev Feb 10 33 GOST Measurement Application User Manual Field Description Sampler Sets in seconds how long the pulse to the device Duration needs to remain on Whenever the sampler exceeds the defined accumulated volume Sample Accum the system turns on the discrete output for the amount of time set in this field 3 Pr
43. plication User Manual Field Description Alarm Sets a value that defines an inactive zone above the Deadband Low Alarm limits and below the High Alarm limits This deadband prevents the system from setting and clearing the alarm continuously when the input value is oscillating around the alarm limit Units are m3 hr or km3 day dependent on the Time Basis fo Alarming selection RBX Alarming Sets the Spontaneous Report by Exception RBX or SHBX alarming options for the meter run Note SRBX Alarming requires you to properly configure your communications ports Valid values are Disabled RBX Alarming is turned off On Alarm When the point enters an alarm Set condition the FB107 generates a Spontaneous Report by Exception message to the host On Alarm When the point leaves an alarm Clear condition the FB107 generates a Spontaneous Report by Exception message to the host On Alarm In either condition an RBX message Set and generates to the host Clear 3 Click Close to proceed to Section 3 3 to view GOST flow values 38 Rev Feb 10 GOST Measurement Application User Manual 3 3 GOST Flow Values Screen Rev Feb 10 Use this screen and its tabs to view calculated flow values To access this screen 1 From the Directory Tree select User Program GOST Flow Program 2 Double click Display 33 GOST Flow Values 3 Double click 1 GOST 1 The GOST Flow Values screen displays showing the Current Values tab
44. reen mam ROCLINK 800 GOST Flow Setup FB107 File Edit View ROC Configure Meter Utilities Tools Window Help D c bd gu MU Me SORR E J Point Number 1 GOST 1 GOST Flow Program Status Program Running No Error Meter Tag GOST 1 Meter Description Meter 1 Description Active Flow Calculation GOST 8 563 97 Active Properties Calc AGAS 92 Detailed Atmospheric Pressure Gravitational Acceleration C Calculate Enter Calculate C Enter 101 325 kPa 3 736412 M Sec2 Pipe Orifice Probe Ref Temp 00 DegC Ref Temp 200 Deg C Material Coeff A 94 10 6 Material Coeff A 4 10 6 Material Coeff B 74 10 9 Material Coeff B 74 10 8 Material Coeff go 10 12 Material Coeff C 6 0 10 12 Interior Roughness 0 1 mm Initial Comer Radius 0 05 mm Inspection Period n Years Base Pressure 1101 325 kPa Elevation 500 0 Meters Base Temperature 20 0 Deg C Latitude 35 0 Degrees Force Recalculation Pressure Tap C Set Gauge Upstream Clear C Absolute C Downstream Pie Save As Auto Scan 2 Update Close gt CERNE 3154M Figure 23 GOST Flow Setup Advanced tab 2 Review the values in the following fields Field Description Atmospheric Select either Calculate or Enter for the value in kPa Pressure of the atmospheric pressure absolute at the metering location If Calculate is selected the value is calculated from Elevation
45. s 32 33 Clear Start Stop Status Running Download User Program File E Program Files Gost_FlowlCalc_5 bin Browse Mame GOST Flow Program Download amp Start Download Version Rev 1 01 Created 7252008 1 22 19 PM CAC On 746 Size B4B Figure 9 Select User Program File 1 Click Browse in the Download User Program File frame The Select User Program File screen displays see Figure 10 2 Select the path and user program file to download from the CD ROM Program files are typically located in the Program Files folder on the CD ROM As Figure 10 shows the screen lists all valid user program files with the BIN extension Rev Feb 10 9 GOST Measurement Application User Manual Select User Program File Look in Z3 Program Files gost flowcalc 5 bin My Documents My Computer File name gost properties 3 bin oI Files of type User Programs bir Cancel Figure I0 Select User Program File 3 Click Open to select the program file The User Program Administrator screen displays As shown in Figure 11 note that the Download User Program File frame identifies the selected program and that the Download amp Start button is active User Program Administrator x User Programe Installed in Device 1 No Program Mame No Program 2 Mo Program Version Library Version 4 Mao Program 5 GOST Flaw Program Created DRAM Used D 6 Mo Program CRC O20 FLASH Used
46. s value when the enter K value option is selected 15 Ksh Value R O Float 4 Any IEEE float value 1 0 Ksh correction coefficient value 16 Kp Value R O Float 4 Any IEEE float value 1 0 Kp correction coefficient value 17 Kre Value R O Float 4 Any IEEE float value 1 000217 Kre correction coefficient value 18 Coefficient Z Value R O Float 4 Any IEEE float value 0 0 Coefficient Z value 19 Pipe Diameter at Flowing R O Float 4 Any Positive Floating 0 0 Pipe diameter adjusted to flowing temperature conditions Temperature Point Number in millimeters 20 Orifice Diameter at Flowing R O Float 4 Any Positive Floating 0 0 Orifice Annubar probe or Venturi tube diameter adjusted Temperature Point Number to flowing temperature conditions in millimeters Rev Feb 10 49 GOST Measurement Application User Manual Point Type 31 GOST Flow Setup Parm 21 GOST Alarm Status Name 22 GOST Calc Enable 24 Venturi Tube Type 50 Access R W R W R O R W Data Type UINT8 UINT8 String UINT8 Length 10 Range 02 0x20 OxT7E for each ASCII character Default 0 Description of functionality and meaning of values Indicates if a GOST specific alarm is active 0 No GOST specific alarms are active 1 At least one GOST specific alarm is active Specifies if the GOST program should calculate flow 0 Do not calculate flow for meter run 1 Calculate flow based GOST standard for
47. s 30 3 2 5 GOST Flow Setup Sampler tab a A ease anna nana a cr sans 33 3 2 6 GOST Flow Setup Calibration Factors tab ccccccssseseececeeeeeeeeeeeeeeeeeeeeaeeeeeeeeeeesaeaaeees 35 3 2 7 GOST Flow Setup Alarms tab cccccccccccccsssseseceeeeeeeeeeeseeeeeeeeeseeeeeseeeeessueasseeeeeessssaeaaeses 37 3 3 GOST Flow Values Screen cccccccccsseeeccceeecceeeessececeeeesaeesseeeeeeeseeaseeeeeeeessaeaseseeeeeeeseaaeees 39 3 3 1 GOST Flow Values Current Values tab cccccccccecccssseeeeeeeeeeeeaaeeeeeeeeeseuaeeeseeeeeeessaeaaeees 41 3 3 2 GOST Flow Values Calculated Factors tab cccccccssseeseeeeeeeeeeaeeeeeeeeeeeeeaeaseeeeeeeeesaaas 42 3 4 Saving the COnfiQuration ccccccccccsssseeceeeeeceeeeeeeeceeeeeeeseeseeeeeeeeeeeeeeeeeeeeesseeeeeeeeeeeeeasagess 43 Chapter 4 Reference 45 4 1 Point Type 28 GOST Properties Configuration and Calculated Values 46 4 2 Point Type 31 GOST Flow Setup eec a A cc sai ana a Eae a ROO iain 48 4 3 Point Type 92 GOST Flow Values ae ierra oes a cuba sea s Danse dee das 51 Hev Feb 10 lil GOST Measurement Application User Manual This page is intentionally left blank IV Hev Feb 10 GOST Measurement Application User Manual Chapter 1 Introduction This chapter describes the structure of this manual and presents an overview of the GOST Measurement Application for the FloBoss 107
48. se Expired Meter Tag This read only field shows the user defined name for the selected meter run GOST Measurement Application User Manual Field Description Meter This read only field shows the user defined Description description for the selected meter run Active Flow This read only field indicates the specific flow Calculation calculation in use Active This read only field indicates the specific properties Properties Calc calculation in use Note The GOST Flow Values screen like GOST Flow Setup screen has a tab format Sections 3 3 1 through Section 3 3 2 discuss the requirements for each tab on the GOST Flow Values screen 40 Rev Feb 10 GOST Measurement Application User Manual 3 3 1 GOST Flow Values Current Values tab Use this tab which displays when you access the GOST Flow Values screen to view meter flow information xa ROCLINK 800 GOST Flow Values Eile Edit View ROC Configure Meter Utilities Tools Window Help D c kl gi VY am Mh See Ol amp E 2 hk Point Number 1 GOST 1 Y GOST Flow Program Status Program Running No Error Meter Tag GOST 1 Meter Description Meter 1 Description Active Flow Calculation AGA7 96 Active Properties Calc AGA8 92 Detailed Current Values Calculated Factors Input Values Uncorrected Flow 500 0 km3 D ay Static Pressure 150 0 kPa Flowing Temperature 50 0 Deg C Instantaneous Rates Flow Rate Energy Rate Mass Rate 46944 02
49. sure Click to display the Select TLP screen and define your TLP selection The value field shows in kPa the static pressure If Manual appears use the Values field to enter a engineering units value for the static pressure input Otherwise the Values field indicates the current input value Sets the input that senses the temperature of the flowing gas Assigns the point type logical and parameter TLP of the I O value for the temperature Click _ to display the Select TLP screen and define your TLP selection The value field shows in C the temperature If Manual appears use the Values field to enter an engineering units value for the temperature input Otherwise the Values field indicates the current input value Sets Displays in millimeters the inside diameter for the pipe near the orifice plate or Annubar probe in this meter run Sets in millimeters the uncorrected Annubar probe diameter orifice diameter or Venturi tube diameter If Annubar is selected as the Calculation Method this read only field shows the diameter calculated by the program If GOST 8 563 97 Orifice GOST 8 586 05 Orifice or Venturi is the selected Calculation Method sets a user defined diameter Sets in kPa the low flow cutoff point When the differential pressure value of the metering device is less than this value the system sets the calculated flow rate to zero and if alarming is enabled records a No Flow alarm in the Alarm Log
50. the GOST Flow Setup screen mam ROCLINK 800 GOST Flow Setup FB107 File Edit View ROC Configure Meter Utilities Tools Window Help D c kl gi Ww ht SeORR HE Point Number 1 GOST 1 GOST Flow Program Status Program Running No Error Meter Tag GOST 1 Meter Description Meter 1 Description Active Flow Calculation GOST 8 563 97 Active Properties Calc AGAS 92 Detailed Flow Alarms Time Basis for Alarming f Alarm on Daily Flow Rate C Alarm on Hourly Flow Rate LowAlamLimit 0 0 km3 Day High Alarm Limit 10000 0 km3 Day Alarm Deadband 0 0 km3 Day RBX Alarming Disabled C OnAlarm Set C On Alarm Clear On Alarm Set and Clear Pim Save As Auto Scan 2 Update Close b TONSEINES 9164M Figure 27 GOST Flow Setp Alarm tab 2 Review the values in the following fields Field Description Time Basis for Sets the time base for which the system generates Alarming alarms Valid values are Alarm on Daily Flow Rate or Alarm on Hourly Flow Rate The default is Alarm on Daily Flow Rate Low Alarm Limit Sets the value to which the calculated flowrate must fall to generate a low alarm Units are m3 hr or km3 day dependent on the Time Basis fo Alarming selection High Alarm Sets the value to which the calculated flowrate must Limit rise to generate a high alarm Units are m3 hr or km3 day dependent on the Time Basis fo Alarming selection Rev Feb 10 37 GOST Measurement Ap
51. thod is Annubar xa ROCLINK 800 GOST Flow Setup FB107 fie G t ye GOC Confoue Mete mises Toos DG i i gu Port Number 11 GOST ti GOST Flow Program Statue Program Running No Emo Window Help Ao mw WE PFRSORGP Dv Mete Tag GOSTE Metes Descsition Meter I Descrpbon VY CY gt Acteve Flow Caleuishen AGA3 52 Azine Properties Cale AGAS 5Q Datadad Garsea ines Adverced Fhad Properte Semoter Cotran Factors Alger GOST Conhgurabon GOST Flow Calculstion Enabled Dirabled Caiculston Method Verdun Verdun Type Cau Unhasied Averaging Techrique Integral Hupka Penod f Plow Dependert Linear IM 110 Minute C Plow Dependent fomulac Plow Weighted Linear Flow Alaming Plow Weufind Formule Enabled C Disabled Active Nama No Flow Low High Birt Severs AaoScm E update Cxe ary Figure 21d GOST Flow Setup General tab Calculation Method is Venturi 21 GOST Measurement Application User Manual 1 Review the values in the following fields Field GOST Flow Calculation Calculation Method Sensor Type K Value Averaging Technique 22 Description Sets the run status of the GOST program Valid selections are Enabled the program performs the flow calculation defined in the Calculation Method field or Disabled the program allows flow to be calculated by the embedded AGA ISO 5167 or other flow calculation user program Sets the calculation m
52. tween a DEVICE and a KEY Licenses on DEVICE Application Name App Code Version Quantity Time Created Connect to KE Move ta DEVICE Add License Remove Licenses on KEY 2 FOF 40272008 02 09 17 Pl ETRERI S TES 3152 i RAS 7 Expiration a OF 02 2008 02 09 28 PM GOST Properties 31523 PAS 3 xr 1 m No Expiration i 123455783 License Key Event Log Serial Number TimeStamp amp ction UserID Vendor ID amp pplicatian M ame Previous Quantity Mew Gluantit Figure I Transfer Licenses Between a Device and a Key Rev Feb 10 GOST Measurement Application User Manual Note This screen has three sections The upper portion Licenses on Device shows any software licenses installed on the FB107 The middle portion Licenses on Key shows software licenses on the license key The lower portion of the screen License Key Event Log provides a rolling log of the last eight events related to this license key 3 Select the key based licenses you want to transfer to the FB107 GOST_FlowCalc as shown in Figure 1I 4 Click Move to Device ROCLINK moves one instance of the license from the key to the FB107 and updates the screen Transfer Licenses Between a DEVICE and a KEY Licenses on DEVICE Application M ame Vendor Mame App Cade Version Quantity License Source Expiration Time Created 1 GOST_FlowCale AAS 31523 1 00 0 1 Key Mo Expiration OF 02 2008 02 09 17 PM GO57_Properties AAS 31523 1 00 0 1 Key No
53. up General tab Use this tab which displays when you access the GOST Flow Setup screen to define the calculation method used by the program xum ROCLINK 800 GOST Flow Setup FB107 5e E31 Yew BOC Confoue Mete ses Toos D c P gu Port Number 11 GOST 1 9 GOST Flow Program Stahur Program Running No Emo Window Heo Now WE FRO mov Meter Taz GOST 1 Metre Decesption Mater N Descrption Active Flow Calculator AGA3 92 Active Properties Cale AGASSO Datadad Geran ines Advarced Fhad Propertes S ormpler Coltvaten Factors Alem GOST Conhgurahon GOST Flow Caladan Enabled C Dicabled Catculston Method GOST 855357 Odc Top Type Coree Averaging Techrique Integral Mulhpber Penod Plow Dependerit Linear IMP 10 Meter C Plow Dependent f omulsic C Plow Weighted Linen Flow Alyma C Flow Weaghied Formulae Enabled Disabled Active Nama No Flow Low High Figure 21a GOST Flow Setup General tab Calculation Method is GOST 8 563 97 xa ROCLINK 800 GOST Flow Setup FB107 fe f t Yew BOC Confoue Mete ses Toos Window Heb Dc e gu cA oe MM TSoEM LR Pw Fort Nube 1 GOST 1 GOST Flow Program Statue Program Running No Emo Mete Tag GOST 1 Mete Descegtion Mater M Description Arive Flow Calculsterr LAGA3 52 Acte Properties Cale AGAS 5Q Detaled Garasi neus Advanced Fhad Properties Samgler Coltraton Fosters Alem GOST Contigueston GOST Flow Caledon
54. when there is no measurable flow and performs a straightforward linear average of the remaining samples to compute the minute and hour values The value specified in the Low Flow Cutoff section of the Inputs tab determines the values When no flow occurs all values are sampled TTETTTTTTETTTTTTTTTETTTTETTETTETETTTETETTTTCSHTITTETITITTETITITTITITITTETETETTITETTTTETITTTTETETTTTETITTTTITITTTTETITTTTETITTTTITITI TETTE TTETETETTETETITTETETITTTTITTTTITITTTTTTITITTTTITTTTTTETTTTETIETITTTTITITTTTITTTTITITITTEITITITT Rev Feb 10 GOST Measurement Application User Manual Field Description Averaging Flow This method discards samples for Technique Dependant periods when there is no flow continued Formulaic However in calculating the average this method typically takes the square root of each sample before averaging the samples together and then squares the result This formulaic method produces a slightly lower value than the linear method Flow This method does not discard any Weighted samples instead it weights each Linear sample by multiplying it by a flow value square root of the differential pressure measured during the sample period Next a linear average is calculated by dividing the sum of the flow weighted sample by the sum of the flow values This result includes minute and hourly values that are more reflective of short periods of high flow Flow This method combines the flow Weighted weighting action
55. with the formulaic Formulaic averaging technique both of which were described previously Integral Sets in minutes how frequently the system calculates Multiplier Period the combined correctional factors known as the Integral Multiplier Value IMV per the API measurement standard Chapter 21 Section 1 for the orifice flow equation The default IMP is 1 minute it can be no more than 60 minutes in length and cannot be less than 1 minute Flow Alarming Sets whether alarms are generated by the program and saved in the alarm log Valid values are Enabled and Disabled Active Alarms Indicates the alarm status If an alarm is activated an alarm icon displays at the bottom of the screen Possible alarms are No Flow Low High Manual and GOST Note This field displays only if Flow Alarming is set to Enabled 2 Click Apply to save any changes you have made to this screen 3 Proceed to Section 3 2 2 to define meter inputs Rev Feb 10 23 GOST Measurement Application User Manual 3 2 2 GOST Flow Setup Inputs tab Use this tab to define inputs for the selected meter To access this screen 1 Select the Inputs tab on the GOST Flow Setup screen mam ROCLINK 800 GOST Flow Setup FB107 File Edit View ROC Configure Meter Utilities Tools Window Help D c gix Wom ht Seo i 2 RE Point Number 1 GOST 1 GOST Flow Program Status Program Running No Error Meter Tag GOST 1 Meter Description Meter tt1 Des