Home
Manual
Contents
1. JP5 defines type of used end of line switches OFF NC type output switches closed at standby active when opened ON NO type output switches opened at standby active when closed JP6 defines the way gate is controlled by the use of transmitter buttons inactive in modes 3 i 4 see table above OFF operates with one transmitter button only in OPEN STOP CLOSE STOP OPEN cycle ON operates with two transmitter buttons where button one controls OPEN STOP OPEN cycle and button two controls CLOSE STOP CLOSE cycle JP7 used to reverse directions of gate movement facilitates controller installation OFF controller delivers live phase supply to OPEN terminal at gate opening and to CLOSE ter minal at gate closing ON reverse live phase supply is delivered to CLOSE terminal at gate opening and to OPEN terminal at gate closing JP8 used to reverse functionality of end of line EOL switches facilitates controller installation OFF EOL switch KO stops gate opening and EOL switch KC stops gate closing ON reverse EOL switch KO stops gate closing and EOL switch KC stops gate opening JP9 flashing of warning courtesy lamp before gate movement OFF gate movement and warning flashing of courtesy lamp start simultaneously on hand transmitter or wall switch use ON flashing of warning courtesy lamp starts 3 seconds before gate movement JP10 reaction on IR barrier disturbance at gate c
2. 3 Programming set on time of auxiliary output CH2 a Press control unit PRG switch LED lights on for more than 2 and less than 8 seconds Releasing the switch PRG LED sets off b Press transmitter button designated to control CH2 output LED sets on and the CH2 relay output sets on c After required CH2 set on time has lapsed press the same transmitter button again flashing LED confirms end of the procedure NOTICE If time between second and third transmitter button pressing is shorter than 0 5 second then the CH2 output is programmed for bistable operation set ON set OFF 4 Deleting all transmitters in controller s memory this procedure should be performed if a transmitter is lost or stolen Press control unit PRG switch PRG LED lights on and hold over 8 seconds until PRG LED starts flashing and then release the switch Flashing LED confirms end of procedure Transmitter memory in is deleted and controller does not respond to transmitter s control signals Programmed motor and CH2 timings remain unchanged To learn transmitter s to controller follow pt 1 of programming procedures NOTES 1 Performing procedures 2 amp 3 above is possible with wall switch or transmitter already learned to controller s memory 2 Gate motor rotation timing is manufacturer set to ca 4 seconds Required motor timing should be programmed individually elmes elmes pl www elmes pl Elmes Electronic 10 2014 All rights reserv
3. SLIDING GATE AUTOMATION CONTROLLER 230VAC powered Elmes STP elmes electronic The controller is designed to use in remote radio controlled sliding gate automa tion system powered by one 230VAC single phase inductive motor capable of mov ing gate in two directions It provides the following operating functions and features e Hopping rolling code KEELOQ transmission allowing high level of control command security e Operation with up to 112 Elmes Electronic made 433 92MHz band hand transmitters and or wired wall switch Remote control accepting one or two transmitter s buttons control command Operation modes manual auto close and two auto parking modes Auto close mode with preset PAUSE time from 1 second up to 4 minutes Operation with end of line switches NO or NC types normally opened or normally closed at standby Programmable motor operation time allowing controller use in gate automation without installed end of line switches Operation with NC type normally closed output Infrared IR protective barrier Auto open function on IR barrier disturbance while in gate close movement Gate STOP security switch input halting gate s movement in any direction Courtesy lamp output warning flashing or steady lighting modes Separated auxiliary relay output NO NC type controlled by additional hand transmitter button Installation facility function allowing reverse gate movement and reverse end of line switches fu
4. ed
5. lose movement OFF gate stops and starts backwards movement ON gate stops NOTE When Parking Mode 1 or Parking Mode 2 is selected JP10 should be set to OFF Infrared barrier input FK R barrier disturbance while in gate opening movement has no effect In closing movement the reaction is described at JP10 setting The effect of IR barrier disturbance in PAUSE time is explained at JP4 description Emergency STOP input Activation of emergency input STOP stops the gate in opening as well as closing movements For as long as the input remains activated the gate can not be operated TECHNICAL SPECIFICATION Controller power supply mains 230VAC power draw 4VA maximum Gate motor relay rating 2 x NO 16A 250VAC maximum Courtesy lamp output 5A 250VAC maximum Auxiliary relay output CH2 rating NO or NC jumper selected galvanic separated 1A 24VDC or 0 5A 125VAC IR barrier power supply output 24VDC 150mA max polymer fuse protected IR barrier input NC type normally closed at standby Emergency STOP input NC type normally closed at standby EOL switches input NC type normally closed or NO type normally opened Gate motor rotation timing 1s up to 4 min the same in open or close rotation Auxiliary control output CH2 timing 0 5s up to 2 min Gate PAUSE time 1s up to 4 min Controller superhet receiver for 434 MHz band Controller board dimensions I w h 95 90 34 mm Manufacturer s Limi
6. nal of gate 230VAC motor i OPEN start up capacitor terminal NOTICE Inputs FK and STOP should be OPEN open rotation motor phase wire terminal middle motor neutral wire terminal CLOSE close rotation motor phase wire terminal CLOSE start up capacitor terminal courtesy lamp output connected to COM if not used If EOL switches are not used inputs KC and KO should be left disconnected with JP5 set ON Description of STP control terminals ZFK infrared barrier supply 24V 150mA max COM ground terminal FK _ infrared barrier signal connect to COM if not used STOP gate stop security input connect to COM if not used WR gate control wall switch input COM ground terminal KO End Of Line open switch if EOL switches are not used set JP5 to ON KC End Of Line close switch if EOL switches are not used set JP5 to ON CH2 auxiliary relay control output opened at standby if jumper NC NO is set NO or closed if jumper is set NC PROGRAMMING PROCEDURES 1 Learning remote control transmitters to controller s memory up to 112 transmitters max NOTICE If the transmitter will be used to control gate operation and auxiliary output CH2 JP1 should be set ON if gate only JP1 should be set OFF After transmitters are learned the JP1 should be set according to selected operating mode of courtesy lamp a Press shortly PRG switch LED lights on b Press selected transmitter bu
7. nction ality set by jumpers OPERATION MODES Elmes STP controller operation modes are set by 10pos DIP Switch placed on controller s board JP1 sets courtesy lamp output operation mode OFF flashing warning lamp flashing slower in gate opening movement and faster in closing movement ON lighting lamp lights steady on gate s movement Courtesy lamp output operating mode depends on settings made with JP1 and selected gate operation mode JP2 amp JP3 Lighting Lamp Mode JP1 ON Gate Operation Mode Warning Lamp Mode JP1 OFF JP2 OFF JP3 OFF flashes fast Sets OFF on gate stop PAUSE time after gate stop All Other Modes G opening flashes slow PAUSE flashes Lamp lights in gate movement and slow PAUSE ends flashes fast G clos 60 seconds after gate stop ing flashes fast G closed sets OFF JP2 JP3 determine the way gate is controlled by hand transmitter or wired wall switch JP2 OFF 1 Manual Mode gate starts moving on transmitter button use Next use stops the gate JP3 OFF Opened gate will not auto close Gate closing is made by transmitter button use JP2 ON 2 Auto Close Mode the use of transmitter button starts gate cycle operation with OPEN JP3 OFF PAUSE CLOSE steps The gate can be stopped at any time by transmitter button use If the gate is fully opened then after PAUSE time will auto close The use of transmitter button in PAUSE time sets off pause time count and next
8. o follow respective EU regulations and standards in particular compliance with EN 12453 EN 12445 EN12635 EN12604 EN 60204 1 EN60335 1 standards and machinery directive 98 37 WE related to gate automation Manufacturer of the controller declares compliance of the product with respective EU standards Manufacturer s CE Declaration included CAUTION Automated sliding gate can cause danger to humans and objects within range of its operation To avoid accidental injury or damage it is necessary to fit protective photo infrared barriers on both sides recommended of the gate Barriers must be in stalled in such a way as to secure that in no circumstances human or moving object access to moving gate is possible Barriers installed on both sides of gate should be connected in series CAUTION The controller is 230VAC mains powered Installation with power connected is dan gerous and can cause electric shock close EOL switches open Wall switch STOP input ol Oo id Sosaa transmitter Description of STP mains 230VAC connection terminals L live phase wire terminal of 23VAC mains ca ble NOTICE Live phase wire of mains supply cable MUST be connected to L N neutral wire terminal of 230VAC mains cable terminal and Neutral wire of mains ca PE ground wire terminal of 230VAC mains cable ble to N terminal of the controller PE ground wire termi
9. ted Warranty Elmes Electronic products carry two year manufacturer s warranty as from date of purchase The warranty is limited to the replacement of faulty original parts or repair defects of improper manufacture Damage faulty use or improper handling by the user or installer as well as any changes in product s hardware or software caused by the user violets the warranty and all due repair costs will be charged Elmes Electronic shall not be responsible for any damage human or material caused by its products failure to operate cor rectly Manufacturer ELMES ELECTRONIC 54 611 Wroclaw Poland ul Avicenny 2 tel 48 717845961 fax 48 717845963 Elmes Electronic reserves the right to change product specification without prior notice KEELOQ is a registered trademark of Microchip Technology Inc STP CONTROLLER INSTALLATION The Elmes STP controller is delivered without casing and is intended for direct installation inside gate gear motor shelter housing Installation should well protect the controller against harsh environmental conditions such as water high humidity heat and dust In order to extend operating range of remote control hand transmitters an external antenna suitable for 434 MHz radio band should be used with its coaxial cable connected to antenna terminals ANT on board of the controller NOTE The coniroller is only a part of automatic gate installation and it is entirely a responsi bility of the installer t
10. tton once PRG LED switches off c Press the same transmitter button again Slowly flashing LED in controller confirms the transmitter is learned and end of procedure NOTICE Number of transmitters learned to controller s memory is limited to 112 learning 113 will remove the first learning 114 will remove second etc Removing lost or stolen transmitter from memory requires deleting all transmitters and learning the remaining ones again NOTICE If while in transmitter learning mode JP1 was set ON and transmitter button 1 was used the button will control gate operation while button 2 will control aux output CH2 In later need to control gate operation with two transmitter buttons JP6 should be set ON buttons 1 amp 2 would control gate operation while button 3 of the transmitter would control CH2 output 2 Programming electric tube motor rotation time and PAUSE time a Press control unit PRG switch LED lights on for more than 2 and less than 8 seconds Releasing the switch PRG LED sets off b Press on hand transmitter button or wired wall switch to start motor rotation PRG LED lights on c When required motor rotation time has lapsed max 4 minutes press the transmitter button or wired wall switch again LED sets OFF and the electric motor stops if not stopped by EOL switch earlier d After required PAUSE time has lapsed press transmitter button again the PRG LED flashing slowly confirms end of the procedure
11. use of the button closes the gate JP2 ON 3 Parking Mode 1 the use of transmitter button starts gate cycle operation with OPEN JP3 ON PAUSE CLOSE steps The use of transmitter button while gate is opening has no effect while in PAUSE mode starts the pause time count again The use of transmitter button while gate is closing stops the gate and after 1 second break starts opening In this control mode gate is operated by one transmitter button only state of JP6 has no meaning JP2 OFF 4 Parking Mode 2 with gate stopping command the use of transmitter button starts JP3 ON gate opening cycle with OPEN PAUSE CLOSE steps The use of transmitter button while gate is moving stops the gate Next use of transmitter button starts the opening cycle again The use of transmitter button in PAUSE time stops pause time count and next button use starts PAUSE time count again In this control mode gate is operated by one transmitter but ton only state of JP6 has no meaning JP4 limits PAUSE time to 5 seconds on photo barrier disturbance IR barrier disturbance while in PAUSE time stops pause time count On IR barrier clearance gate control is resumed in one of two ways depending on JP4 state OFF PAUSE time count is continued if mode 2 Auto Close is selected or PAUSE time is re started if mode 3 or 4 are selected ON after 5 seconds gate starts closing in mode 2 only In control modes 1 2 amp 3 JP4 should be set OFF
Download Pdf Manuals
Related Search
Manual manual manualslib manual car manuale digitale manually meaning manual timesheet manual transmission manual wheelchair manual arts high school manually update your device drivers windows manual definition manual for courts martial manual labor manual lawn mower manual muscle testing manually register devices with autopilot manual muscle testing grades manual transfer switch manualidades manual blood pressure cuff manual handling manual transmission cars for sale manual digital manual pdf manual autopilot enrollment
Related Contents
Registers - Jérôme Saint AirLive G.DUO User Manual Samsung S20A550H Samsung WA87RA คู่มือการใช้งาน Installation and Maintenance Manual Aerocool Strike-X Air オリジナルヒートガン オリジナルヒートガン Whirlpool Signature SAWB600HQ0 User's Manual SERVICE MANUAL - X-Core Technology Co., Ltd. RESTROOM ITEM 01 専用ライニング お手入れ はじめに Copyright © All rights reserved.