Home
Installation Guide: C3COM-3
Contents
1. Control Card C3COM 3 e 3 3 Series Control Card Crestron C3COM 3 Installation Items required to install the C3COM 3 are already attached to the unit The only tools required are a Phillips screwdriver and a grounding strap Follow the procedure below CAUTION The C3COM 3 contains electrostatic sensitive devices ESD observe precautions for handling ESDs to avoid damaging the card NOTE If installing the C3COM 3 into an AV3 it is assumed that the CAGE3 Control Card Expansion Cage accessory has been installed 1 Disconnect power from the control system 2 Use the Phillips screwdriver and remove two screws and blank faceplate from the control system 3 Align the C3COM 3 with the card guides in the open slot and slide the expansion card into position 4 Firmly press on both ends of the C3COM 3 faceplate to seat the expansion card into the control system connector 5 Tighten the thumb screws to secure the C3COM 3 to the control system 6 Reapply power to the control system C3COM 3 is not compatible with the 2 Series PRO2 AV2 PAC2 Even installed in the CAGE3 Control Card Expansion Cage the card is not compatible with any 2 Series control system 4 e 3 Series Control Card C3COM 3 Installation Guide DOC 7302C Crestron C3COM 3 3 Series Control Card Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations If further assistance is required please
2. Crestron C3COM 3 3 Series Control Card 3 COM Ports Installation Guide CRESTRON This document was prepared and written by the Technical Documentation department at gt cCRESTHON Regulatory Compliance This product is Listed to applicable UL Standards and reguirements by Underwriters Laboratories Inc o dus As of the date of manufacture the C3COM 3 has been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling CEC Federal Communications Commission FCC Compliance Statement CAUTION Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try t
3. contact a Crestron customer service representative C3COM 3 Troubleshooting TROUBLE POSSIBLE CAUSE S CORRECTIVE ACTION C3COM 3 does not function Control system is not receiving power Circuit card is not properly seated in slot Verify power to the control system Verify C3COM 3 is properly inserted into control system slot per procedures in this guide electrostatic Installation Guide DOC 7302C 3 Series Control Card C3COM 3 e 5 Cable from Verify wiring Connect C3COM 3 to only the required pins controlled for each equipment is communication type incorrect Controlled Cable Wiring Confirm and or check device does not problems the cable pinouts respond using the Crestron Cable Database software or refer to the user manual for the controlled device Loss of Improper Check that all ground functionality grounding connections have due to been made properly discharge 3 Series Control Card Crestron C3COM 3 Further Inquiries To locate specific information or to resolve questions after reviewing this guide contact Crestron s True Blue Support at 1 888 CRESTRON 1 888 273 7876 or refer to the listing of Crestron worldwide offices on the Crestron Web site www crestron com offices for assistance within a particular geographic region To post a question about Crestron products log onto the Online Help section of the Crestron Web site www crestron com onlinehelp F
4. eiu de y YD nA y Y dg y yf 5 Eurther Ingulriesn A 6 Future Updates sn rias 6 Return and Warranty Poli umi 7 Merchandise Returns Repair Service ccccceesseesceesceesceeeceseceaeeaecaecaeeeseeeneeeeeeerees 7 Crestron Limited Warranty esteen eee n ara N a ERE E Ae A EE EE EEEa EAEN 7 Installation Guide DOC 7302C Contents e i Crestron C3COM 3 3 Series Control Card 3 Series Control Card 3 COM Ports C3COM 3 Introduction The C3COM 3 is a 3 Series control card that provides three COM ports Each COM port supports bidirectional RS 232 RS 422 or RS 485 and all COM ports comply with IEC 61000 4 5 Installation Class 4 surge immunity levels The card is designed to install in a control card expansion slot of a 3 Series Control System model PRO3 or AV3 or 3 Series Card Interface model CEN CI3 1 or CEN C 13 37 1 AV3 requires CAGE3 Control Card Expansion Cage accessory to enable use of 3 Series control cards 2 The C3COM 3 is not compatible with the 2 Series PRO2 AV2 PAC2 Even installed in the CAGE3 Control Card Expansion Cage the card is not compatible with any 2 Series control system Installation Guide DOC 7302C 3 Series Control Card C3COM 3 e 1 3 Series Control Card Specifications Crestron C3COM 3 Specifications for the C3ICOM 3 are listed in the following table C3COM 3 Specifications SPECIFICATION DETAILS Communications RS 232 422 485 Environmental Temperature Humidit
5. hout notice
6. irst time users must establish a user account to fully benefit from all available features Future Updates As Crestron improves functions adds new features and extends the capabilities of the C3COM 3 additional information may be made available as manual updates These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision Check the Crestron Web site periodically for manual update availability and its relevance Updates are identified as an Addendum in the Download column 6 e 3 Series Control Card C3COM 3 Installation Guide DOC 7302C Crestron C3COM 3 3 Series Control Card Return and Warranty Policies Merchandise Returns Repair Service 1 No merchandise may be returned for credit exchange or service without prior authorization from Crestron To obtain warranty service for Crestron products contact an authorized Crestron dealer Only authorized Crestron dealers may contact the factory and request an RMA Return Merchandise Authorization number Enclose a note specifying the nature of the problem name and phone number of contact person RMA number and return address 2 Products may be returned for credit exchange or service with a Crestron Return Merchandise Authorization RMA number Authorized returns must be shipped freight prepaid to Crestron 6 Volvo Drive Rockleigh N J or its authorized subsidiaries with RMA number clearly
7. marked on the outside of all cartons Shipments arriving freight collect or without an RMA number shall be subject to refusal Crestron reserves the right in its sole and absolute discretion to charge a 15 restocking fee plus shipping costs on any products returned with an RMA 3 Return freight charges following repair of items under warranty shall be paid by Crestron shipping by standard ground carrier In the event repairs are found to be non warranty return freight costs shall be paid by the purchaser Crestron Limited Warranty Crestron Electronics Inc warrants its products to be free from manufacturing defects in materials and workmanship under normal use for a period of three 3 years from the date of purchase from Crestron with the following exceptions disk drives and any other moving or rotating mechanical parts pan tilt heads and power supplies are covered for a period of one 1 year touch screen display and overlay components are covered for 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from Crestron or an authorized Crestron dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any Crestron shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse accidental damage modification or i
8. mproper installation procedures Furthermore this warranty does not cover any product that has had the serial number altered defaced or removed This warranty shall be the sole and exclusive remedy to the original purchaser In no event shall Crestron be liable for incidental or consequential damages of any kind property or economic damages inclusive arising from the sale or use of this equipment Crestron is not liable for any claim made by a third party or made by the purchaser for a third party Crestron shall at its option repair or replace any product found defective without charge for parts or labor Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the unexpired portion of the warranty Except as expressly set forth in this warranty Crestron makes no other warranties expressed or implied nor authorizes any other party to offer any warranty including any implied warranties of merchantability or fitness for a particular purpose Any implied warranties that may be imposed by law are limited to the terms of this limited warranty This warranty statement supersedes all previous warranties Installation Guide DOC 7302C 3 Series Control Card C3COM 3 e 7 amp gt CRESTHON Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 Tel 888 CRESTRON Fax 201 767 7576 www crestron com Installation Guide DOC 7302C 2032617 01 13 Specifications subject to change wit
9. o correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Industry Canada IC Compliance Statement CAN ICES 3 B NMB 3 B The specific patents that cover Crestron products are listed at patents crestron com Crestron the Crestron logo 3 Series and 3 Series Control System are either trademarks or registered trademarks of Crestron Electronics Inc in the United States and or other countries UL and the UL logo are either trademarks or registered trademarks of Underwriters Laboratories Inc in the United States and or other countries Other trademarks registered trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products Crestron disclaims any proprietary interest in the marks and names of others Crestron is not responsible for errors in typography or photography 02013 Crestron Electronics Inc Crestron C3COM 3 3 Series Control Card Contents 3 Series Control Card 3 COM Ports C3COM 3 1 Introduction Se OO RN 1 SS ON 2 Physical Description os 3 Installation o o elo dt lo e o el eae thas F 4 Problem Solving ea dd a De end a e ed e e e 5 Troubleshootinge
10. y Heat Dissipation Dimensions Height Width Weight Available Accessory CNSP XX 2 e 3 Series Control Card C3COM 3 For 2 way device control and monitoring 41 to 113 F 5 to 45 C 10 to 90 RH non condensing 4 Btu h 0 98 in 25 mm 5 00 in 127 mm 4 oz 114 g Custom Serial Interface Cable Installation Guide DOC 7302C Crestron C3COM 3 3 Series Control Card Physical Description The C3COM 3 shown below is a circuit board fastened to a faceplate The card is manufactured to easily fit into an unoccupied slot in a 3 Series Control System or 3 Series Card Interface C3COM 3 Faceplate SEE MANUAL FOR 5 C A pels okt os E oXBE E ae H EEE ERE O 5m CRESTRON COM 1 COM 2 COM 3 C3COM 3 5 00 in 127 mm The faceplate contains three identical 5 pin 3 5 mm detachable terminal blocks Interface connectors for COM 1 3 ports are provided with the unit Connector details are as follows e Bidirectional RS 232 422 485 ports e Up to 115 2k baud hardware and software handshaking support C3COM 3 Pin Out PIN RS 232 RS 422 RS 485 1 GND GND GND 2 TX TX TX RX 3 RX RX Not used 4 RTS TX TX RX 5 CTS RX Not used A ground terminal connection is recommended but not required Ground potential difference must be under 4V Installation Guide DOC 7302C 3 Series