Home
Product Guide
Contents
1. Tr u bo 1 ASPT10S v2 0 e 12V DC external supply e 110db 1m sound level e LED 2Hz pulsed alarm light e Reserve battery 1 2A 12V optional e Timer for siren roger 41 PCBA EMS Scope of offered services e Electronic Manufacturing Service e OEM Assembly e SMT Assembly e Manual Solder Assembly e Engineering amp Testing Solution e Flooding with resin masses e Tampon printing e CNC details processing e Marking with labels 42 www roger pl PCBA EMS characteristic e Full process Electronic Manufacturing Service e SMT and through hole e PCB boards 457 x 407 mm e 0402 0603 0805 1210 and 2512 placement e Two fully automated SMT assembly lines e PHILIPS TOPAZ COMET CSM94 assembly machines e EKRA automatic online screen printer e MVP 1820 Ultra AOI optical inspection machine e MVP 1820 AOI optical inspection machine e Two SMT 460 reflow ovens e Experienced components sourcing team e Professional engineering staff to provide technical support e Handwork package e OEM and ODM services welcome e Small orders accepted roger A3 F N aad Special Versions a ME c L WA aes A OTT eee FR TER e_o gmn OEM Products Aside from versions catalogued in this document devices software and other changes specific to customer expecta manufacturer ROGER offers manufacturing special tions Each case of non standard manufacturing requires devic
2. Proximity Readers 13 56 MHz Mifare PRTxxMF Series DOTT PRT12MF ISO IEC 14443A Mifare outdoor reader writer connecting cable 0 5 m silicone keypad with backlight two function keys dark grey light grey Available versions and symbols radiUS PRT62MF ISO IEC 14443A Mifare miniature outdoor reader writer connecting cable 0 5 m 000 dark grey light grey silver metallic Available versions and symbols Symbol Description Symbol Description PRT12MF G Dark grey case keypad PRT62MF G Dark grey case PRT12MF L Light grey case keypad PRT62MF L Light grey case PRT12MF BK G Dark grey case without keypad PRTI62MF S Silver metallic case PRT12MF BK L Light grey case without keypad PRI66MF ISO IEC 14443A Mifare outdoor reader writer bolted contacts mountable directly ina 60 mm gang box 1 dark grey white silver metallic Available versions and symbols Symbol Description PRT66MF G PRT66MF W White case PRT66MF S Dark grey case Silver metallic case PRT64MF ISO IEC 14443A Mifare outdoor reader writer bolted contacts silicone keypad with backlight mountable directly in a 60 mm gang box 1 dark grey silver metallic Available versions and symbols Symbol Description PRT64MF G Dark grey case PRI64MF S Silver metallic case roger 15 Standard Access Controllers PRXX1 Serles The PRx
3. dark grey white silver metallic Available versions and symbols Symbol Description PRT66EM G Dark grey case PRT66EM W White case PRT66EM S Silver metallic case PRT64EM VP EM 125 kHz outdoor vandal resist proximity reader connecting cable 0 5 m top part of reader s case and keys made with aluminium alloy and covered with silver metallic coat card reading distance up to 8 cm mounta ble directly in a 60 mm gang box roger 13 Proximity Readers 13 56 MHz Mifare PRTXxMF Series 14 The PRTXxMF series readers is a group of access terminals which are designed for using with ISO IEC 14443A and Mifare cards Devices belonging to this series have identical functio nality and differences between them are limited only to operation environment mechanical construction and style of casing Each PRTxxMF reader can be used as standalone access control device or as a Slave unit con nected to the external controller In first case PRIXXMF reader based on the configuration settings autonomo usly controls single door entire logic is centralized in the reader itself In second case PRTIXXMF reads card or PIN and then send data to access controller which takes further action Features e 12VDC supply e 13 56 MHz Mifare cards e Reads CSN MSN or SSN number e CSN SSN and MSN card numbers e Programmable data output format e Formats Wiegand 26 66bit Magstripe Clock and data RS232 RACS Ro
4. a MFC 2 13 56 MHz Mifare ISO size thin PVC card with printed number photo ID pictures and text prin ting possible with dedicated PVC printers 1k bytes memory MFKF 2 E 13 56 MHz Mifare 1kB key fob MFC 3 13 56 MHz Mifare ISO size thin PVC card with printed number photo ID pictures and text prin ting possible with dedicated PVC printers 4k bytes memory MFKF 3 13 56 MHz Mifare 4kB key fob www roger pl Overprint with personalization It is possible to put on cards a graphical customization picture name ID number barcode etc according to de sign delivered by customer The possibility to make custom print is offered on proximity cards made of PVC with ISO dimensions 85mm 54mm and the thickness of 0 8 mm MASTER CARD cards EMC 1 EMC 4 MFC 1 MFC 2 and MFC 3 It is possible a ae to make two kinds of print e thermosublimation printing color e thermotransfer monochrome printing black Offset overprint We offer also possibility to order proximity cards with high quality color overprint without personalization Each inquiry related to this type of printing Is considered individually You can find more information at www roger pl a rn Cards Overprint Accessories 30 CP 1 Horizontal card punch with hole ISO stan dard size CH 1 Durable plastic card holder vertical or horizontal use ISO standard size NL 1 Neck lanyard flat 15mm width
5. silicone keypad with backlight mountable directly in a 60 mm gang box 1 dark grey silver metallic Available versions and symbols Symbol Description PRT64LT G Dark grey case PRT64LT S Silver metallic case DOTT PRTA2IT EM 125 kHz indoor proximity reader bolted contacts plastic keypad with backlight Bell function key light grey Available versions and symbols Symbol Description PRT42LT B Black case keypad PRT42LT L Light grey case keypad PRT42LT BK B Black case without keypad PRT42LT BK L Light grey case without keypad CLASSIC is 1916 soog i gaae souu PRT32LT EM 125 kHz indoor proximity reader bolted contacts silicone keypad with backlight configurable by user into version without keypad roger Proximity Readers EM 125 kHz PRTXXEM Series PRTXxEM series readers is a group of access terminals designed for using with EM 125 kHz proximity cards Devices belonging to this series have identical functionality and differences between them are limited only to operation environment mechanical construction and style of casing Each PRTXxEM series reader can be used as an universal identification point connected to the access controller or configured for autonomous work as a simple access con troller for a single door In the first case the readers func tionality is limited only to reading an identifier card PIN and sending data to an external
6. I O simulator that allows Plastic case for XM 2 Adjusting separation module simulation of input signals door and RM 2 modules used for connecting F7 F10 contact exit button etc and GP60 GP90 readers and visualization of output signals other third party readers door lock alarm signaling to PRxx2 series controllers current arming mode etc adjusts output signals logical levels to controller s input lines Separates readers input lines so that they can not inter fere with each other p F4708022 802 KWS1K EP 7 12 Mechanical lock designed for An attachment for screws Battery 7Ah 12V mounting in metal case ME 1 fixing SL2000S1K code lock s keypad Screws are non stan dard so that unauthorized demounting is made difficult 32 www roger pl K N N Presentation and Training Materials DB 1 O NEW Demonstration training system for PRxx1 series controllers A set of controllers and readers has been mounted on the 100x60x3cm board and connected together to form a sample networked access control system consisted of 4 bidirectional passages DB 1 system can be used for training ACS installers and designers as well as for presentation the system at end users premises Symbol Description DB 1 PL Demonstration board with PRxx1 series controllers Polish version DB 1 EN Demonstration board with PRxx1 series controllers English version DB S Portable stand together with case for demon
7. a s W RR Sn n c expanded Its area of activity which has led to a necessity to enlarge the company s manufacturing ability At present the company has a new manufacturing building which has been designed and built according to the newest technology standards and in keeping with relevant industry principles The products we offer have acquired a repute in the Polish market This can be proved by the network of permanent customers from all over the country At the same time dynamic development of our offer during the recent years has led to acquiring many new customers in the countries from Europe and Asia www roger pl Ho ODA Ln 10 12 14 16 18 20 21 22 23 24 24 25 25 26 26 ACCESS CONTROL A Guide To Roger Access Control Solutions Code Locks e S12000 Code Locks e Proximity Card Lock RACS 4 Access Control System Proximity Readers EM 125 kHz PRTXXLT Series Proximity Readers EM 125 kHz PRTXxEM Series Proximity Readers 13 56 MHz Mifare PRTxxMF Series Standard Access Controllers PRxx1 Series Advanced Access Controllers PRxx2 Series CPR32 SE Network Controller RACS Management Software RARC Software Cards Programming Sets Other Readers e Administrator s Reader e Biometric Readers e Long Range Readers Auxiliary Equipment e Communication Interfaces 27 28 28 28 29 30 33 35 37 39 40 41 42 44 45 e Expanders Transponders e EM 125 kHz e 13 56 MHz MIFA
8. COM Port UT 2USB USB Port UT 4 Computer Network Communication Interface TCP Bridge COM USB or Ethernet a Access Network H1 E COM USB or Ethernet X Access Network 2 i Z l S RS485 Comm Bus s gt Access Controller Z a Up to 250 networks per individual access system S Up to 32 controllers per network r 1 Up to 1000 controllers per system DX vT 5 4 REEN gt VZ Managing computer COM USB ot Ethernet i x l Access Network 250 gt S Reader B Reader nf Managing computer with PR Master program Proximity Readers EM 125 kHz PRIXXLT Series 10 PRTXXLT series readers is a group of access terminals desi gned for using with EM 125 kHz proximity cards All members of this series have identical functionality and differences between them are limited only to operation environment mechanical construction and style of casing PRIXxLT series readers can operate in many common communication standards e g Wiegand Magstripe Clock and Data RACS so they can cooperate with majority of controllers from different vendors available on the market Notice PRIXxLT series readers can not operate in standalone mode as autonomous access controllers Such functionality provides PRIXXEM and PRIXxMF series readers PRT62LT Miniature EM 125 kHz outdoor proximity reader connecting cable 0 5m dark grey light grey silver metallic Available versio
9. band blue color length 80cm CP 2 CP 3 Horizontal card punch with Vertical card punch with hole extended durability ISO hole extended durability ISO standard size standard size BC 1 NC 1 Badge clip for photo ID cards Neck chain with silver finish metal clip with plastic band length 91cm and metal snap NL 2 Neck lanyard flat 15mm width band blue color with Roger logo length 80cm www roger pl as nal ek l ea AC Oo Ed en nt K P a Accessories m wt the g M bad ma Se ee h Ls tll Se ME 1 ME 2 Metal enclosure for PR402 access con White color metal enclosure with 80VA transformer dedica troller or CPR32 SE network unit includes ted for use with ZMPR 1 installation kit up to four PR402 or AOVA transformer key lock available on six PR302 301 boards can be assembled in this case using request symbol F4708022 802 ZMPR 1 also other combinations of PS and XM modules available using this set X8 X3 x40 X16 x1 ZMPR 1 ME 2 S NEW Set of two metal shelves and additional Metal enclosure with 80VA transformer and ZMPR 1 assembly kit accessories dedicated to install up to four pre prepared for installation of 4 PR402 modules PR402 boards and or other RACS modules into single ME 2 metal enclosure Modules and battery shown in the photo are not included in the ME 2 S kit roger 31 Accessorles lt amp 2 10S 1 NEW PE 1 PR GP BRD
10. controller which takes fur ther action In case of work in a standalone mode PRTxxEM terminals can independently supervise a single door using data entered in the process of their configuration Features e 12VDC supply e EM 125 kHz cards e Programmable data output format e Formats Wiegand 26 66bit Magstripe Clock and data RS232 RACS Roger and others e Various ways of PIN and keypad codes transmission e LED and Buzzer controlled through separate inputs e Outdoor installation e Can be used for Q5 card programming required licensed version of RARC program e Programmed manually or from PC e Free managing software RARC The PRTXxEM series readers are equipped with program mable input and output lines They can also cooperate with XM 2 type I O expander which provides two relay outputs and two NO NC inputs Using an XM 2 expander substan tially improves a general security level of an access point being controlled because it physically separates a decision point reader from the working element blocking the door relay from XM 2 module Every PRTIXXEM series reader can cooperate with a secondary PRT reader thus allowing for controlling the door from both sides The PRTXxEM series readers have built in relay output and are equipped with RS232 interface which can be used for data communication or for programming a reader from a PC Every PRTXxEM series reader can be used as card programmer EMC4 cards however for t
11. readers XM 8 BRD Addressable input output expander eight NO NC inputs and eight relay outputs can be used with PRxx2 controllers as an elevator control module PSAM 1 BRD Alarm module for PS series power supplies PS10 PS20 and PS15v24 Device indicates battery failure low battery level lost of AC supply Alarm can be Indicated on transistor outputs or digitally transmitted to access controller roger 27 Transponders 28 EM 125 kHz a ze aye ae al ae ans aa EMC 1 EMC 2 EMC 3 EM 125 kHz ISO size thin PVC EM 125 kHz ISO size thick Clam EM 125 kHz ISO size thick proximity card photo ID pictures shell proximity card with printed Clamshell proximity card and text printing possible with number with printed number exten dedicated PVC printers ded reading range eit ail ww EMC 4 EMKF 1 EM 125 kHz ISO size thin PVC proximity card with Q5 chip EEPROM EM 125 kHz key fob reading 264 bits the card number CSN can be programmed by any PRTxxEM range may be reduced by series readers running under RARC software Windows card can be approx 50 when using the used with PVC printers photo ID pictures and text printing possible fob versus the card 13 56 MHz MIFARE MFC 1 13 56 MHz Mifare ISO size thin PVC card with printed number photo ID pictures and text printing possible with dedicated PVC printers 64 bytes memory MFKF 1 13 56 MHz Mifare Ultralight key fob en th
12. 2010 Product Guide O a J C O O N WY q lt T Rae O K 4 q UY S899999 m C TET T BEREN i bi ob Be BS SESESEREaeee Bee B LC TTT LL MEMERNMENEHNHARN SSeS LT ETT ETT Seen B CE E AAD E E OE OEE E L E X SRR ERE ESE eS SS SSSR E E E ECE E E E HUSRRRESHRBSREES BRSRFBESHESHURESS SSSR Rees SEEGERS S TET CL CE ELE SMG ih RL idi aa HANA ENEP Sneu Su amp 3 aaah Se 1 M RAE 8880 TLitiii S K 111 1 lZ BES 1999999 09909 AL LALA TF WH d ERR GANEBBZAT S IZ BEN ASABE mea EJ PDBSTR SBS M LAH 56HEMSU GE HAB B B B E SREAEDEEB asnes BEREK San re 3 Bt The network of foreign partners ROGER was established in 1991 Its area of activity is designing and manufacturing security electronic devices especially in the field of electronic access control Thanks to our long experience the products offered present a high functionality and stylistic level while maintaining high reliability For manufacturing our products we use components from renowned vendors only and we continually train our personnel and refine the manufacturing process Within recent years the company has considerably u seen a TL um TTT a Er EEEE EEEE md RRR 7 npunta SSSR ESSERE uns LC L SSSSSSSEESESEESCEEEESESe E A BSW H See NERNSnT HE SIH ee HH as 2 ttrrtt HEHH HH E oa a Hi SSE RD frit ag SSSR ERE BREN LI TETE LT TTT TTT L TTT a H
13. MF series readers Basic version of the software Programming 13 56 MHz ISO 14443A and Mifare cards allows for complete reader s configuration as well as for Programming EM 125 kHz Q5 cards downloading events logged in its memory This version is Complete reader s configuration free Extended version of the program allows for utilizing Events downloading and viewing PRTXXEM and PRIXxMF series readers for proximity cards User management programming and requires purchasing a specific license Saving reading reader s configuration settings to from RARCLICENSE external file Communication through RS232 interface requires TXD RXD and RTS lines RARC soe Pie Opie immat fente ord Cand popane tiok About Hens ting ET nat a Basic version of the program for PRTxxEM PRTxxMF series seh a a ee LEE SZ readers management distributed free of charge does not ESZES ey lT ear require any license can be downloaded from the Rogers e SHa Nc m Yd Atco key OBER bap Web Site at www roger pl Tone beh MRED Sec Be ad gg tl Sat peer Z GE nega pak err Chaki apl de WHEELS pabet Ay Hast De geed iodi Reshu sr HI E Ihe psi leier 2 Yen Clot Carel CEN Chp ein mia j A H sdaget p t a RARC LICENSE O E N IMD ees breiar 734 koui rren kid rnan Licensed version of the RARC software allows for utilizing mainan 1 Te PRIXXEM series readers for programming EMC 4 cards and utilizing PRTxxMF readers for programming MEC MFG2 and MFC3 cards The lic
14. PR32 SE network controller In standalone mode PRxx2 autonomously supervise two way door passage and do not need to communicate with PC nor any other equipment events are registered in their internal buffer and time related functions are managed by built in real time clock For this mode connection to PC is necessary only for configuration and events download or for real time events monitoring When working in integrated access control system PRxx2 continuously exchanges data with CPR32 SE panel which collects events occurred in the access system in its internal buffer and Is responsible for all global type functions e g anti passback zones alarm zones Features e Two way single door access controllers e Built in EM 125 kHz reader PR302 and PR602LCD e Connection of one external reader two way door control e Connection of two PRT series readers PR402 e Support for Wiegand Magstripe PRT Roger readers and others e 12VDC supply PR302 PR602LCD e 18VAC or 12VDC supply PR402 only e Built in 1 5A buffered supply module PR402 e Three programmable NO NC inputs 4 on PR402 e Two programmable 1A transistor outputs e One programmable 1 5A relay output 2 for PR402 e RS485 communication bus e Free topology of communication bus star or tree topo logy allowed e 4000 users e 99timeschedules e 250 user groups e Built in 32 000 event buffer e Local APB e Global APB requires CPR32 SE in the system e Global A
15. RE Cards Overprint Accessories Presentation and Training Materials TIME AND ATTENDANCE RCP Master Software GUARD TOUR SYSTEM Guard Tour System SECURITY Dialers Power Supplies Alarm Sirens SERVICES PCBA EMS Special Versions OEM Products Advertising Materials Table Of Contents roger 3 Access Control Loac e hel A Guide To Roger Access Control Solutions Code Locks Electronic code locks are the simplest and the cheapest way to implement electronic access control There are two code locks categories in the Rogers offer code locks of SDC type working with proximity cards and SL2000 locks family work ing with PINs only In case of SDC lock user identification Is performed using proximity cards keys This product is extraordinarily easy in installation and usage and can be successfully installed by Proximity Readers The basic purpose of proximity readers is to read the card code and possibly PIN code and sending them to a parent device which takes the decision about how the system would react on using the relevant card PIN ROGER offers proximity readers of many types within the PRT series We offer readers adapted for cooperation with cards of EM 125 kHz as well as Mifare 13 56 MHz standards All the PRT series readers PRTXxLT PRTXXEM PRTXXMF can be configured for work in a terminal mode as slave devices Access Controllers The company offers two access controllers famil
16. all products e Access to newest descriptions of all products and servi ces e User friendly functionality access to each product website by double click method expanded search mechanism downloads connected to particular product website related articles feature presentation of various versions of products screenshots galleries products as solutions and many more Direct technical support provided by Frequently Asked Questions section FAQ section is a set of answers to most popular questions that our technical support department meet with Section Is continuously updated and expanded with new topics and themes Complete downloads base Direct communication with ROGER company through thematic contact forms By using these forms it s possi ble to send a feedback regarding products and services ask a technical question or send an inquiry Access to additional materials for registered users And many many more roger ROGER sp j 82 400 Sztum Gosciszewo 59 Poland T 43 55 272 0132 L 48 55 272 0133 E roger roger pl www roger pl amp 5 S Ss a 3 3 5 D lt 5 S 8 T D a gt a a 2 S G 3 S z u lt 2 5 VL kel a wm gs D S sg Edition 03 Version 1 0 EN O 2010 ROGER sp j
17. ation board English version g DB S Portable stand together with case for demonstration board E DB S ST Stationary stand for demonstration board roger 33 34 Time and Attendance ro se The RCP Master allows for creation of worktime and The RCP Master has been developed using the Microsoft NET attendance reports based upon the event log imported background and Is designed for Windows XP and Vista from CSV and XML text file formats The employee worktime Operating systems This program is dedicated for Human attendance time is calculated according to the specific Resources Departments in small and medium sized com rules defined by the program operator taking into account panies and is offered with a license for 50 250 and 250 defined earlier worktime calendars employees Also there are single and multi station versions available Features e Importing events log from RACS v 4 2 5 38 and above e Support for rounding up the time of beginning and e Importing events log from CSV and XML text file formats finishing the work e Exporting reports in the Adobe Acrobat pdf Microsoft e Support for payable and unpayable breaks Excel xls Microsoft Word doc Rich Text Format rtf e Support for overtime work and Crystal Reports rpt file formats e Reports Employee Groups Employees Calendars e Exporting worktime attendance reports in XML Access Points T amp A Event Log Worktime Leave Limits e Definition o
18. ation standards e g Wiegand Magstripe Clock and Data RACS Thanks to this they can cooperate not only with Roger controllers but also with majority of controllers from different vendors available on the market The controllers of this series offer wide range of functio nalities not only strictly related to access control but also allowing for integration with alarm systems performing Automation as well as Time amp Attendance functions There is a free software available PR Master 4 which can be used for management of systems consisting of PRxx1 and PRxx2 series controllers The program allows for configuring the system and monitoring it in an online mode There is also a SDK package available for the PR Master which allows for software integration of the access control system with third party systems and programs using API Code Locks SL2000 Code Locks SL2000 series electronic code locks were designed as simple and cheap access control devices that identify users by PIN codes Features e One 1 5A 30V relay output and two transistor outputs e Alarm signaling on the transistor output ALARM e Input for connecting a Door Contact e Input for connecting an Exit Button e Administrator code for programming and users codes management e Master Code for controlling the lock s mode of operation e 55 user codes for door opening e Possibility for temporary lock s blocking after three unsuccessful code entering at
19. cated to install up to four PR402 boards into single ME 2 metal enclosure ME 2 S Metal enclosure with SOVA transformer and ZMPR 1 assembly kit pre prepared for installation of 4 PR402 modules roger 19 CPR32 SE Network Controller 20 CPR32 SE Network Controller is an optional Roger Access Control System RACS component Using CPR32 SE in the system expands its functionality with specific features When used with PRxx1 series controllers CPR32 SE allows e One CPR32 SE unit per single access network with up to 32 controllers e Real time clock with battery back up e Event buffer 250 000 e Programmable inputs outputs e Two 1 5A 30V relay outputs e Two 1A 15V transistor outputs CPR32 SE BRD RACS 4 network controller module board without casing metal case is offered separately symbol ME 1 for logging events and defining time based access rights as well as to realize global type functions such as APB zones or alarm zones In case of PRxx2 series controllers CPR32 SE provides a global type functions only APB alarm zones e Four NO NC inputs e RS485 interface free topology e Relay output for alarm states signaling e Firmware upgrade e 1 5A buffered power supply e 18 22 VAC supply e CE mark The RACS software pack consists of several programs which are dedicated for administration and management of all aspects of RACS system e Support for all PRxx1 and PRxx2 access controlle
20. ed mode of power conversion and are adopted for operation with reserve batteries All models are protected from overload and disconnect battery when discharged DI DIT PS10 13 8V 1 2A output place for 7Ah 12V battery PS10 BRD Switched mode power supply module input 18 22VAC output 1 2A 13 8V operation with 7Ah 12V battery TWN Hit PS20 13 8V 2A output place for 7Ah 12V battery PS20 BRD Switched mode power supply module input 18 22VAC output 2A 13 8V operation with 7Ah 12V battery PS supplies can be used as power source for electronic equipment controllers readers etc or for actuators door locks motor locks magnetic locks etc TINH UT PS15v24 27 6V 1 5A output place for two 7Ah 12V batteries PS15v24 BRD Switched mode power supply module input 32 36VAC output 1 5A 27 6V operation with two 7Ah 12V batteries www roger pl The ASP sirens offer acoustic and light alarm indication Both units are equipped with tamper detection circuit which indicates detachment from the wall as well as attempt to open the siren s enclosure a HII WI Hit II ASPTIOLC e 12V DC external supply e 110db 1m sound level e LED 2Hz pulsed alarm light Alarm Sirens Moreover the ASP110S may indicate lack of the external supply Both sound and light are controlled by separate inputs Acoustic alarm can be selected from five types of sound modulations
21. ense can be ordered by phone or through Internet 22 www roger pl CPK RR EM 125 kHz cards programming set CPK 1 includes PRT66EM proximity reader 10pcs of not programmed Q5 proximity cards RUD 1 communication interface CD ROM with RARC software and license key pya NEW 13 56 MHz Mifare cards programming set CPK 2 includes PRT66MF proximity reader 10pcs of not programmed Ultralight proximity cards RUD 1 communication interface CD ROM with RARC software and license key Card number 7664483322 C Lock card GR Data Sector Manager Data sector Sector number O a Key FFFFFFFFFFFF Key Bs FFFFFFFFFFFF Read sector Blocks in sector Block 0 ED9938E 2EEOD 487A4876C52D836DF774 Insert GUID Write Block 0 ASCH Peale vlan Paste text Block 1 66942BC0782F4888444948A781185035 Insert GUID White Block 1 Block 2 02AG43F200504BFD855418394E 05BF1D Insert GUID Wiite Block 2 Aste ike Pry S198 Paste text Access rights to the sector Key A FFFFFFFFFFFF Key B FFFFFFFFFFFF Access to Block 0 read AB write AIB increment AB decrement transfer restore AJB RJR Access to Block 1 read AIB write AIB increment AR decrement transfer restore AJB Access to Block 2 read AIB write AIB increment AIB decrement transfer restore AIB RJE Access to Config Block read NA uie B read access AIB wite access B readB NA wr
22. es versions OEM made according to customer speci submitting individual quote and may require one time cost fication Depending on the specific device it is possible to for preparing necessary instrumentation or documentation order custom connecting cable length printing logo on the Average time for satisfying orders containing products in devices case changing keypad backlight color manufactu special versions falls within the range from 4 to 8 weeks ring case with non standard color modifications in devices n 44 www roger pl Advertising Materials lente T il H H U iy S ie l TUTE I i tafi Hal k i t i A H 7 d pir iti aui a it ik i 1 Comprehensive Professional Time amp Attendance roger i Access Control Solutions Seared PEAD 1 Professional Access Control 2 Comprehensive Time amp Attendance Solutions PATROL II LCD Portable reader for proximity badges and checkpoints with non erasable events memory Professional Access Control an Time amp Attendance roger Recording of Inspection roger Solutions Seek ewe Rounds and Field Actions ww roger pi 3 Professional Access Control a Recording of Inspection Rounds and Field Actions and Time amp Attendance Solutions Notes To learn more about ROGER s offer please visit us at www roger pl The webpage provides e Presentation of complete offer which enables quick and easy access to
23. ess readers and control lers programming from PC v gt w a De a a a L RUD 1 O NEW UT 2 UT 3 RUD 1 is an universal portable commu RS232 to RS485 communication RS232 to RS422 communication nication interface dedicated for Roger interface interface access control devices Product has been designed for installers which uses laptops for configuration and manage ment of Roger access controllers and readers RUD 1 is powered straight from the USB port and has built in supply module which provides 12V voltage for programmed device RUD 1 can be used for e Communication with RACS access control system e Configuration and management of PR series access controllers from PR a Master software fo R e Configuration and management of PRIXXEM and PRIXxMF series readers from RARC software e Firmware upgrade in PR series access controllers e Firmware upgrade in PRIXxEM and PRIXXMF series readers e In other applications as USB to RS485 converter UT 2USB UT 4 USB to RS485 communication RS232 RS485 RS422 to Ethernet interface communication interface 26 www roger pl RM 2 BRD Double relay module 1 54 30V load triggering by O or 12V signal electronic board only Auxiliary Equipment Expanders XM 2 BRD Addressable input output expander two NO NC inputs and two relay outputs dedicated to work with PRxx1 and PRxx2 series controllers as well as with PRTXXEM and PRTxxMF series
24. f calendar days workday additional work Individual Calendars etc day holiday day off etc e Possibility to create any set of reports with the Report e Definition of attendance and absence types leave Wizard summary reports for the whole group as well unjustified absence lunch break etc as reports for individual employees e Definition of maximum and minimum time of presen e Possibility to automatically send individual reports by ce i e maximal daily cigarette break limit minimal e mail to the employee e mail address worktime etc e Operator activity log e Additional options related to late comings early exits e Support for relational database in MS Access file format inclusion the time worked before and after usual workti e Possibility to use local database or database shared thro me hours etc ugh the network e Definition of pass types entrance exit duty exit etc e Possibility to define password for access to the database file e Definition of program operators and their privileges e Possibility to encrypt the database file e Possibility to correct and insert missing T amp A events and e Support for compacting and repairing the database file to modify absences e Possibility to manipulate the database from any external e Definition of holiday limits and report of their usage program i e own implementation the procedure of e Individual worktime calendars with the possibility to cor adding new events from external system rect ca
25. ger and others e Various ways of PIN and keypad codes transmission e LED and Buzzer controlled through separate inputs e Outdoor indoor installation e Mifare card programming required licensed version of RARC program e May operate as an offline standalone access controller e Up to 120 indexed users with card and or PIN stand alone mode The PRTxxMF series readers are equipped with program mable input and output lines They can also cooperate with XM 2 type I O expander which provides two relay outputs and two NO NC inputs Using an XM 2 expan der substantially improves a general security level of an access point being controlled because it physically separates a decision point reader from the working element blocking the door relay from XM 2 module In standalone mode each PRTXxMF reader can operate in pair with second PRT series unit this allows to control door on both sides entry exit The PRTxxMF reader can be used as card programmer however for this purpose the licensed version of RARC program IS required e Authentication Card and or PIN e Event log for 3000 transactions e Built in 1 54 30V relay output except PRT62MF PRT12MF and PRT12MF BK e Two NO NC inputs e Two 150mA transistor outputs e Operation with XM 2 I O extension module e Possible connection of the external PRT series reader two way door control e Programmed manually or from PC e Free managing software RARC e Tamper e CE mark
26. h cable box with a set of fixing screws EDE Snn e Master card for programming 1pc e Card key Spcs e User manual 8 www roger pl The RACS 4 is a networked access control system based The PR Master program exchange data with individual on the PR series controllers PRT series readers XM 2 network through separate serial communication port COM XM 8 expanders CPR network controllers and PR Master or USB or through computer network WAN or LAN managing software The RACS 4 is dedicated for small or middle size access installations and is capable to handle up to 1000 controllers System functionality depends on the type of equipment and up to 4000 users PRxx2 series controllers or up to used in particular installation The RACS 4 can be divided 1000 users PRxx1 series controllers into separate branches which are called access networks up to 250 networks also called subsystems can be integrated in one AC system installation Each network may have up to 32 access controllers connected to RS485 communication bus up to 1200m Tha flanarsal Ctructira af D am Tho Intarnal Ctructira nf 5 Cinala DACC Ala TheG eneral Structure of R PIT The Internal Structure of a Sil ngle RACS I Live monitoring on remote computers with RACS Remote Monitor program CPR32 SE A Network Controller RS485 Comm Bus Optional Free topology Reader Reader Access Controller Up to 32 access controllers in network UT 2
27. his purpose the licensed version of RARC program is required RARCLICENSE e May operate as an offline standalone access controller e 120 indexed users e Authentication Card and or PIN e Event log for 3000 transactions e Built in programmable 1 5A 30V relay output Two NO NC inputs e Two transistor outputs e Operation with XM 2 I O extension module e Possible connection of the external PRT series reader two way door control e Tamper e CE mark E gt _ gt Ff m E _ N dP sali PRT64EM EM 125 kHz outdoor proximity reader bolted contacts silicone keypad with backlight mountable directly in a 60 mm gang box dark grey silver metallic Available versions and symbols Symbol Description PRT64EM G PRT64EM S Dark grey case Silver metallic case Corn wo PRT12EM EM 125 kHz outdoor pro ximity reader connecting cable 0 5 m silicone keypad with backlight two function keys US L dark grey light grey Available versions and symbols Symbol Description PRT12EM G Dark grey case keypad PRT12EM L Light grey case keypad PRT12EM BK G Dark grey case without keypad PRT12EM BK L PRT12EM G B Light grey case without keypad Dark grey case blue keypad backlight E N Proximity Readers EM 125 kHz PRIXXEM Serles radius PRT66EM EM 125 kHz outdoor proximity reader bolted contacts mountable directly in a 60 mm gang box e
28. ies named PRxx1 e g PR311SE PR611 etc and PRxx2 e g PR302 PR402 etc Both PRxx1 and PRxx2 controllers can work autonomously in a standalone mode as well as in a networ ked access control system equipped with CPR32 SE network controller and supervised by a PR Master control software Within each of these families there are devices integrated with a proximity reader and possibly with a keypad e g PR311SE PR611 as well as models requiring connection of external readers e g PR402 PR411DR The PRxx1 series controllers are simpler devices designed for performing most common access control functions They can support up to 1000 users are relatively simple to use and cheap The PRxx2 controllers form a family of advanced access controllers capable of supporting up to 4000 users electricians as well as by DIY amateurs without experience in the field of security systems SL2000 locks identify users through PIN codes Devices from this series offer possibility to program up to 55 different codes and are preferred to be applied in Access Control installations In parallel to controlling access they can also control any device or the system requiring switching of turn on turn off type attached to an external access controller Furthermore PRTIXXEM and PRIXxMF series readers can work in a standa lone mode as autonomous access control points In the terminal mode the readers offer possibility to work in many common communic
29. ific building or area locations and configuring the reader Every checkpoint and person identifier can be assigned with names labels These labels can later significantly improve interpretation of registered events history Features Operates with EM 125 kHz proximity cards and tags LCD display with backlight Non volatile 32 000 event log buffer Guard tour alarms and maintenance events Non erasable event register reconstruction of events cancelled PATROL LCD ON OFF READ Patrol II LCD Patrol II LCD set e Reader e USB cable e Two batteries AA 1 5V e Leather case e Battery charger intentionally Guard Tour System Displays guard and checkpoint names Displays guard tour schedule hints Communication through USB port Battery charging from PCs USB or AC charger Supply from two LR6 AA batteries Resistant to humidity and water condensation Simple and intuitive operation with a single key Up to 8K reads cycles without battery charging High mechanical durability shock resistant for 1 5m free falling Set includes reader USB cable two AA 1 5V rechargeable batteries leather case battery charger PK 1 checkpoint 1pc PK 2 checkpoint Spcs EMC1 proximity card 3pcs CP 1 card case 3pcs Programming and maintenance from computer through USB Free windows managing software Free upgrades of the reader s firmware via USB Warranty and non warranty service Possibility to custo
30. iteB B Write Configuration Block Configuration Block view Other Readers Administrator s Reader JI lt RUD 2 NEW RUD 2 is a miniature portable reader for EM Support for RUD 2 readers can also be imple 125 kHz proximity transponders The reader mented in other programs by using dynamic is supplied from serial USB port which is also library DLL In this case the logic of reader used for communication with the device The handling depends completely on the program s RUD 2 can be used as a card enrolling reader author for RACS Besides it can also be utilized from the free Roger MiniReader software There is also a Dynamic Link Library DLL available for programmers who want to integrate support for RUD 2 in their applications Roger MiniReader application enables to read EM 125 kHz transponders codes through RUD 2 reader The cards read can be saved to a text file CSV format or automatically copied to the clipboard so the card codes can be easy moved to other applications L Se Ad eee a SE 2 A ta ammm Tee 4 ALET KUE Te a A jamimsimam mmaa aman Jammimnas mame EAEE ROGER MiniReader www roger pl F7 F7 biometric fingerprint reader identifies a user from up to 500 templates stored in its memory without use of a card or PIN The F7 can be used as a slave reader connected to access controller or as a standalone access control point with built in relay outp
31. larm Zones requires CPR32 SE in the system e Operation with XM 2 I O extension module e 32 floor lift control requires XM 8 I O extension module e Integration with burglary system through I Os e Building automation through Os In case of communication failure PRxx2 controllers switch automatically to standalone mode and continue door passage control without global functions Events are registered in their internal buffer then Simultaneously to access control every PRxx2 controller can be used as a time and attendance terminal however the PR602LCD unit equipped with 4 line LCD display and a set of 4 programmable function keys is most adequate for this purpose The PR402 may operate with two external access terminals whereas the PR302 and PR602LCD have built in one prox PIN reader and are capable to work with one external reader unit only Access control system based on PRxx2 series controllers can be managed locally through COM USB serial port or remotely by computer network WAN LAN UT 4 interface required e Door operating modes Normal Locked Unlocked Conditional Unlocked e User identification Card or PIN Card and PIN Card only PIN only e Two Persons High Security and other advanced access options e Quick user editing less than 5 seconds per each control ler in system e Management through Ethernet LAN WAN USB or COM e System can be divided into separate branches networks subsystems e Multiple netwo
32. lendar for the specific employee i e working in e Operating systems Windows XP and Vista different time changeovers etc e Free upgrade within the same program version Loc 188272089 10 49 Peat On Dute Exit Bak Aag aed Man C K Poe Sec TEF es a Ul oS Sak ac Uianlies pel x 2 ESS tub AW An da adobe Pe see Hews 7 ve g Ware Sl ate Treron g hi Pd echt Trees olada oc Pewee A Kaal s d T D K arn E T S Sunway 209 li 1 ie a ho M pagename ig T e DOT TTT PR602LCD For worktime logging purposes the Roger company Steeler alde Ea recommends use of PR602LCD controller This controller is ue Sisena equipped with 4 line LCD display and a set of 4 programma E ble function keys which can be used as register type choice buttons entrance exit on duty exit etc The PR6O2LCD is equipped also with a built in event buffer and can work in a standalone or in a networked access control system of RACS type Roger 36 Guard Tour System ON OFF READ E PATROL II LCD is a portable proximity transponders reader designed for tracking persons attendance in designated points of building or area The device is designed mainly for verification of guards routes Nevertheless it can be used in many other situations where there is a need to control people attendance in remote locations PATROL installation is as Simple as mounting proximity checkpoints in spec
33. mize the device CE mark Parameters pointed with star can be achieved when some particular conditions specified in User manual are fulfilled 23 Patrol boston 9 11 35 Patrol Master PK 1 Proximity checkpoint outdo or use can be mounted on a metal base IA Sry Coase KE 2 oh Fosh 4 ose TEE I tat a4 fies winti CONE vob OEYRORE UT SREYA ACR SZCJRE 4 ege v U 4 uina te SKEEF DSEG AGE KEJE theta te ACE SEJT thei TH hE METET ACR CRS METET v PK 2 Proximity checkpoint circle shaped with a mounting hole in the centre can be mounted on the wall or under the wall indoor use tele a 37 Security 38 Telephone dialers make possible to automatically send in formation about emergency conditions fire break in etc to programmed telephone subscribers Recipient is notified by verbal message recorded earlier and possibly by digital cone FT ene f DIALO7M e Recording one 24 second long verbal message e Recording of two verbal messages 3 sec long about an on off state of the inspection mode e Notification of up to eight telephone subscribers e Notification of up to two pager subscribers e One momentary alarm input e One alarm input with delay e Separate input line for switching inspection mode remotely e Alarm signaling output e Output for signaling telephone line failure e Possibility to call telephone dialer from
34. ns and symbols Symbol Description PRT62LT G Dark grey case PRT62LT L Light grey case PRT62LT S Silver metallic case Features e 12VDC supply e EM 125 kHz cards e Programmable data output format e Formats Wiegand 26 66 bits Magstripe Clock and data RACS Roger and other e Various ways of PIN and keypad codes transmission e LED and Buzzer controlled through separate inputs e Outdoor installation except PRT32LT PRT42LT and PRT42LT BK e Manual setup e Tamper e CE mark radius PRT66LT EM 125 kHz outdoor proximity reader bolted contacts mountable directly in a 60 mm gang box L c dark grey white silver metallic Available versions and symbols Symbol Description PRT66LT G Dark grey case PRI66LT W White case PRT66LT S Silver metallic case www roger pl Proximity Readers EM 125 kHz PRTXXLT Series NAA aA a am a sk N 1 3 5 7 g s a K PRT12LT EM 125 kHz outdoor proximity reader connecting cable 0 5 m silicone keypad with backlight two function keys 9 L dark grey light grey Available versions and symbols Symbol Description PRT12LT G Dark grey case keypad PRT12LT L Light grey case keypad PRT12LT BK G Dark grey case without keypad PRT12LT BK L PRT12LT G B Light grey case without keypad Dark grey case blue keypad backlight radius PRT64LT EM 125 kHz outdoor proxi mity reader bolted contacts
35. outside in order to get verbal information about inspection state Della transmission to alarm monitoring station Dialers made by Roger can also be used as a small anti burglary control pa nel with possibility to monitor three alarm lines and outputs for signaling devices such as siren buzzer DIALO9 e Sending information to two alarm monitoring stations e Sending information to two pager subscribers e Sending information to up to eight subscribers notified by a verbal message e One 24 second long alarm message or two messages 11 second long each e Incase of work with two messages a content of message being sent depends on the line the alarm was initiated from Two messages 3 sec long each about a current inspection mode inspection on off e Remote encrypted access to verbal information about dialer s inspection state e Remote and local control of programmable outputs e Remote alarm message receipt e Remote alarm action deletion and arming disarming dialers e Set of control codes of different permissions e Three programmable alarm inputs of NO NC type e Two programmable outputs of open collector type e Telephone line supervising e Supervising connection with alarm monitoring stations e Possibility for programming manually or from a PC UT 1 RS232 TTL communication interface for programming DIALO9 dialer from a PC roger 39 Power Supplies 40 PS series power supplies are utilizing puls
36. red galvanically roger Code Locks Proximity Card Lock SDC66 lock allows to implement a simple electronic access SDC66 has been designed so that its installation and deploy control mechanism in which users are identified by proximity ment could be performed both by professional electrician instal card keys The lock can be utilized in areas where it is necessary lers and by DIY amateurs who have no professional background to limit access to the room to specific group of persons and at A brand new lock is configured with factory defaults in such the same time to free them from the need to carry many traditio a way that in majority of cases its programming will not be nal mechanical keys required Features e Identification by proximity cards keys e The lock can be mounted in the flush mounting box or e Possibility to program up to 120 cards keys directly on the wall e Optionally works with any number of cards keys any e Works outside and inside buildings card key opens the door e Supplied from 12VDC Power Supply Adapter or from e Selectively adds and removes cards keys 12 VAC transformer e Support for Door Contact and Exit Button e Tamper e One relay output 1 5A 30V and one transistor output e CE mark 1A 15V e Alert states signaling radius dark grey white silver metallic Available versions and symbols Set includes Symbol Description a SDC66 lock SDC66 G Dark grey case e Transformer SDC66 W White case e Flus
37. rks doesn t increase system programming time e Advanced Time and Attendance functions PR602LCD e LCD display and 4 programmable function keys PR602LCD e Outdoor installations PR602LCD O only e Tamper e CE mark Advanced Access Controllers PRxx2 Series CLASSIC Leet 10 220S 16 42 TRAMOrDute Exit PR302 PR402 BRD PR602LCD Indoor access controller Single door access controller electronic Outdoor access controller with built in EM 125 kHz proximity module built in power supply with battery advanced T amp A functions built reader bolted contacts support secondary supply output 12VDC 1A in EM 125 kHz proximity re silicone keypad with backlight with overcurrent protection cooperation with ader connecting cable 0 5 m configurable by user into two external access readers power supply silicone keypad with backlight version without keypad 18 22VAC four programmable function keys 4 line LCD display Available versions and symbols Available versions and symbols Symbol Description Symbol Description PR402 BRD Access controller PR6O2LCD I Indoor version bolted electronic module contacts o boad S PR602LCD 0 Outdoor version ME 1 Metal enclosure for connecting cable installation of 1 PR402 0 5 m board includes 40VA transformer ME 2 Metal enclosure for installation of 4 PR402 boards ZMPR 1 required includes 80VA transformer ZMPR 1 Set of two metal shelves and additional accessories dedi
38. rs e Up to 32 controllers in single network e Up to 250 networks integrated in one system e Support for F7 and F10 fingerprint readers e Communication with networks through serial port COM USB or computer network e Real time events monitoring on local and remote computers e Interactive commands to controllers e Operator selectable filtering of events e Online events reports to text files ta Pelbaseor Yi 1 T 19 Tta e cev tate Sore Teas be m Fane A roger EBAR Iei inet LA TAT a va H Quick user update Support for online printer Event notifications via email Time and attendance recording Attendance reports in any user defined areas Visualization of working system on graphical background object map Configurable auto backup Different access levels for program operators Paradox BDE database Export import of database to XML format files OLE Automation SDK E dune mohi nes T R Sette 0 Tak tha a hy a 1 2 ee o go So So So Soie AOG M CSEE gt a eee ee d s T LRR eS RERET gd t board paip Pe IER vard voda ZADEN Read event buffers now Sr ee tm ET Sind chad 01 11 z RN lt IZ Kr das jE a Eii lt Update system now Update clock s Events history Access map Online monitoring RARC Software RARC Software Features RARC software is used for management of PRTxxEM Support for all the PRIXXEM PRIXxMF series readers PRTxx
39. stration board DB S ST Stationary stand for demonstration board DB 2 PEW Demonstration training system for PRxx2 series controllers A set of controllers and readers has been mounted on the 100x60x3cm board and connected together to form a sample networked access control system consisted of 3 bidirectional passages DB 2 system can be used for training ACS installers and designers as well as for presentation the system at end users premises Available versions and symbols Symbol Description DB 2 PL Demonstration board with PRxx2 series controllers Polish version DB 2 EN Demonstration board with PRxx2 series controllers English version i DB S Portable stand together with case for demonstration board DB S ST Stationary stand for demonstration board DB 3 NEW A board demonstrating the Roger company s offer in the field of Access Control Systems Dummy devices together with description of equipment s most important features have been placed on the board of dimensions 100x60x3cm The DB 3 can be useful in merchant posts and showrooms offering Roger products as well as for presenting RACS for potential customers Y I U Im interested in installation Roger Access Control System at their 8 premises Available versions and symbols mr S Symbol Description DB 3 PL Access control devices presentation board Polish version m DB 3 EN Access control devices present
40. tempts CLASSIC 1 bl dels SL2000B Indoor code lock case made with ABS bolted contacts silicone keypad with backlight Devices belonging to this series have identical functionality and differences between them are limited only to mechani cal construction style of casing and operation environment outdoor or indoor use e Possibility for room entrance blockage when the lock is in armed mode e Programmable code length e User indexing e Non volatile memory e Three LED indicators and a Buzzer e Power Supply 10 15VDC e Tamper e CE mark SL2000H ECH Outdoor vandal resist code lock case made with aluminum alloy powder coated painted bolted contacts access to the keypad pro tected by key locked doors silicone keypad with backlight www roger pl SL2000 EC Indoor code lock case made with ABS bolted contacts silicone keypad with backlight mountable directly ina 60mm gang box Dorn io Tee MUL MIT SL2000E Outdoor code lock case made with ABS connecting cable 0 5 m silicone keypad with backlight two function keys Code Locks radius SL2000F VP HETI Outdoor vandal resist code lock top part of case and keys made with aluminium alloy and covered with silver metallic coat connecting cable 0 5 m mountable directly in a 60 mm gang box SL2000S1K Outdoor vandal resist code lock bolted contacts case and keypad made with aluminum alloy and silve
41. ut for a door lock The management of F7 reader can be carried out direc tly from RACS software or by dedicated configuration program through RS232 RS485 or Ethernet Other Readers Biometric Readers F10 F10 biometric fingerprint reader is dedicated for use in access control systems as a biometric identification point with up to 600 templates stored in its memory The F10 can be used only as Wiegand26 34 bit reader connected to the external access controller Reader can be programmed from RACS software or by dedicated program through RS232 RS485 or Ethernet NOTICE Before using the fingerprint reader you need to verify whether the application of the device under particular conditions is consistent with applicable law Advanne Reader TRON A U GP60 Outdoor EM 125 kHz cards reader with extended reading range Up to 60 cm reading range can be achieved when using EMC3 cards Reader is equipped with RS232 RS485 Wiegand26 and Magstripe clock amp data output formats Long Range Readers GP90 Outdoor long range EM 125 kHz cards reader Up to 120 cm reading range can be achieved when using EMC 3 cards Reader is equipped with RS232 RS485 Wiegand26 and Magstripe clock amp data output formats roger 25 Auxiliary Equipment Communication Interfaces Communication interfaces are required for administration and management of the entire access control system from PC They can be also used for acc
42. without keypad PR311SE G B Dark grey case blue keypad backlight PRATIDR SN 4 SINGLE DOH ACNESS CONTROLLER e ae L 7 ts est ly roger CE MUO HH J H eseeesese 8068 naa PRATIDR NEW Single door access controller built in 1 5A buffered power supply operates with exter nal readers 1 or 2 mountable directly in a DIN rail 35mm Standard Access Controllers PRXX1 Series radius PR611 PR621 Outdoor access controller built Outdoor access controller in EM 125 kHz proximity reader built in EM 125 kHz proximity bolted contacts silicone keypad reader bolted contacts mo with backlight mountable untable directly ina60mm directly ina 60 mm gang box gang box 1 e dark grey silver metallic dark grey white silver metallic Available versions and symbols Symbol Description PR611 G Dark grey case PR611 S Silver metallic case PR621 G Dark grey case PR621 W White case PR621 S Silver metallic case PR611 VP NEW Outdoor vandal resist access controller built in EM 125 kHz proximity re ader connecting cable 0 5 m top part of controller s case and keys made with aluminium alloy and covered with silver metallic coat card reading distance up to 8 cm mountable directly ina 60 mm gang box roger 17 Advanced Access Controllers PRxx2 Series 18 The PRxx2 series controllers may operate as standalone access control units or in integrated access control system with C
43. x1 series controllers are designed as the most When communication with CPR32 SE Is broken controllers popular and low cost access control solutions They can automatically switch to standalone mode and continue be used either in standalone or integrated access systems operation with settings as they were when communication for up to 1000 users When used autonomously they do bus failure occurred All PRxx1 units are equipped with not offer time schedules nor buffering of events however RS485 interface which can be use for both programming when operating in system equipped with CPR32 SE network and online communication in networked system Access controller both mentioned features became available control system based on PRxx1 series controllers can be and are provided by this additional device One CPR32 SE managed locally through COM USB serial port or remotely network controller can operate with up to 32 PRxx1 access by computer network WAN LAN UT 4 interface required controllers Features e Built in EM 125 kHz reader PR611 PR611 VP PR621 and e Operation with XM 2 I O extension module PR311SE e Integration with burglary system through I Os e Connection of one external reader PR611 PR611 VP e Door operating modes Normal Locked Unlocked PR621 and PR311SE Conditional Unlocked e Connection of two PRT series readers and or two Wie e User identification Card or PIN Card and PIN Card only gand 26 66 bit readers PR411DR PIN only e 12VDC suppl
44. y PR611 PR611 VP PR621 and PR311SE e Fast programming 15 seconds per each controller in e 18VAC or 12VDC supply PR411DR system e Built in 1 5A buffered supply module PR411DR e Quick user editing up to 3 seconds per each controller e Three programmable NO NC inputs 8 for PR411DR in system e Two programmable 1A transistor outputs e Integration of multiple access networks in one system e One programmable 1 5A 30V relay output up to 250 e One programmable 1 5A 230VAC relay output e Multiple networks doesn t increase system programming PR411DR time e RS485 communication bus e Outdoor installation PR611 PR611 VP PR621 and e Free topology of communication bus star or tree topo PR311SE logy allowed e DIN RAIL 35mm enclosure PR411DR e 1000 users e Tamper e Upto 8 guest type users on each controller in the e CE mark system e 99 time schedules CPR32 SE required e 250 user groups CPR32 SE required e 250 000 event buffer CPR32 SE required e Local APB e Global APB CPR32 SE required e Alarm Zones CPR32 SE required 16 Domo PR311SE Outdoor access controller built in EM 125 kHz proximity reader connecting cable 0 5 m silicone keypad with backlight two func tion keys a E dark grey light grey Available versions and symbols Symbol Description PR311SE G Dark grey case keypad PR311SE L Light grey case keypad PR311SE BK G Dark grey case without keypad PR311SE BK L Light grey case
Download Pdf Manuals
Related Search
Related Contents
POLAR INSTRUMENTS Toneohm 550A Operator PDF fluke_bio_esa620 Telemètre Leica Disto D2 Copyright © All rights reserved.
Failed to retrieve file