Home

G510 Hardware OpenCPU User Manual

image

Contents

1. GPIO Standard Module OpenCPU Module Description 100 pin 22 UART1_RING GAPP_IO_0 Only as output and refer to the notes below for detailes 101 pin 17 UART1_DCD GAPP_IO_1 Only as output and refer to the notes below for detailes 102 pin 16 UART1_DSR GAPP_IO_2 Only as output and refer to the G510 Hardware OpenCPU User Manual Page 10 of 14 Bs FIBOCOM notes below for detailes 103 pin 15 UART1_DTR GAPP_IO_3 Input output low level for default 104 pin 38 LPG GAPP_IO_4 Input output it is available after LPG by default set by sys_set there is a LPG CONTROL option in sys_set to control LPG 105 pin20 UART1_RTS GAPP_IO_5 Output only 106 pin21 UART1_CTS GAPP_IO_6 Input only Note G510 the reused GPIO below need choosen according to the actual situation UART1_RING 100 only as the output when power on the progress of module initialization will last 1 4s uncontrolled low level while the external pull up is invalid SS Agilent Technologies SAT MAR 08 12 08 30 2014 510RING 1 AX 751 88mHz AY 2 96250V B1ORING 510RING Figure 2 1 G510 Hardware OpenCPU User Manual Page 11 of 14 Bs FIBOCOM UART1_DCD 101 only as the output when power on the progress of module initialization will last 1 4s uncontrolled first hign last low level while the external pull up and pull down are all invalid CS Agilent Technologies SAT MAR 08
2. Standard module means the software of the module supports standard AT command which doesn t support OpenCP U function OpenCPU module means the software of the module supports OpenCP U function Customers can make secondary development based on the module download and run customer software After the module is powered up besides its own software you can also load customer software Module Firmware means the software comes with the module usually it is already downloaded by default Customer Software means the secondary development software usually customer need to download it to the module Some interface definitions of the module are different due to different software This document is based on G510 Hardware User Manual and G5 Family OpenCPU API User Manual it introduces some methods and notes of hardware interface design and functional design when you use OpenCPU module G510 Hardware OpenCPU User Manual Page 5 of 14 Bs FIBOCOM 1 2 OpenCPU features Item G510 Base Band RDA8851 MIPS 208MHz Flash Code Space BYTE 512K Flash Data Space BYTE 512K Hardware RAM BYTE 512K UART 3 GPIO 5 INT 2 No limits with file number File storage space is File System 512k each file cannot exceed 100k Unit ms Chigher than 500ms is recommended Software Timer You can enable at most 25 software timers at the Sonwane same time Thread 5 Watchdog Supported
3. HOST UART is a debug UART which is used for downloading calibrating trace and so on it doesn t support any AT command This interface is only used when debugging users only need to connect to the test point Application MCU Direction Module TXD Pin 11 HST_RXD RXD _ Pin 12 HST_TXD 2 2 5 OpenCPU Application Note for HOST UART HOST UART can only output debug data there are two formats Interface Function Input Parameter INT32 sys_eventTrace lt value gt 32 bytes data UINT32 value INT32 sys_textTrace Parameters like printf G510 Hardware OpenCPU User Manual Page 9 of 14 Bs FIBOCOM INT8 fmt 2 2 6 OpenCPU Application Note for Virtual UART Interface Function Input Parameter INT32 sys_at_send UINT8 cmd UINT16 len lt cmd gt AT command string including Ox0d lt len gt string length Void at_resp UINTS8 rsp UINT16 rsplen lt rsp gt AT port data starting address lt rsplen gt the data length 2 3 Sleep Mode OpenCPU module supports sleep mode It goes into sleep mode by ATS24 command via Virtual UART When Customer software invokes the timer of Module firmware it would affect the sleep mode This could further affect the consumption of the module The other operations of sleep mode are the same with Standard module 2 4 GPIO Interface
4. TCP Server Supported UART1 Upgrade module firmware Provided UART1Upgrade customer software Provided Support Remote Upgrade customer software Supported Debug Method UART1 UART2 print and HOST UAR trace G510 Hardware OpenCPU User Manual Page 6 of 14 Bs FIBOCOM 2 Hardware Design 2 1 Power On Off The module power on and off is the two primary phases which are related at the interface connector by the hardware signals POWER_ON VDD The POWER_ON signal is a important signal The VDD signal indicates whether module is powered on or off When this signal is disabling OV module is powered off When it is output 2 85V module is powered on The following table shows definitions of the pins for Power on off Pin No Signal Name Description 14 POWER_ON Power on and off module Low level activated 13 VDD Illustrating module status LDO power output OV module is off LDO power output 2 85V module is on 2 1 1 Turning on the Module For Standard module the module won t start directly after you powered up it is turned off For OpenCPU module normally external circuit is not controlled by any MCU or AP so after the module is powered up it automatically powered on When you design the hardware we suggest you connect POWER_ON pin to the ground via 470ohm 2 1 2 Turning off the Module For OpenCPU module if external circuit is not controlled by any MCU or AP plea
5. 12 20 29 2014 510DCD 1 AX 1 5873Hz AY 2 98250V 29 VBAT D 2 5300to y a zE ae Eq i 510CTS Figure 2 2 UART1_ DSR 102 only as the output when power on the progress of module initialization will last 1 4s uncontrolled continued hign level while the external pull down is invalid ree Agilent Technologies SAT MAR 08 12 22 03 2014 S1ODSRE 1 AX 763 36mHz AYI 2 96250V 27 VBAT BJLODSR 510DSR D 6 5 sir Figure 2 3 G510 Hardware OpenCPU User Manual Page 12 of 14 Bs FIBOCOM UART1_ DTR 103 as input or output and when power on the progress of module initialization will last low level while the external pull up is available E Agilent Technologies SAT MAR 08 12 23 24 2014 510DTR iia 510DTR 1 AX 1 6393Hz AY 2 96250V 510DTR 2 5 INT Interface GPIO Standard Module OpenCPU Module Description PIN41 WAKE_UP falling edge effective need external pull up PIN27 SIM_CD falling edge effective need external pull up Interface Function Input Parameter INT32 sys_set GAPP_OPTION_ID_T id Void arg UINT16 len lt id gt operation ID lt arg gt parameter pointer lt len gt parameter length G510 Hardware OpenCPU User Manual Page 13 of 14 Bs FIBOCOM INT32 sys_gpio_get lt id gt IO number 9 means SIM_CD 10 means WAKE_UP GAPP_GPIO_ID_T id lt level gt return
6. Bs FAISOCom erfect Wireles Bs FIBOCOM Confidential Material This document contains information highly confidential to Fibocom Wireless Inc Fibocom Fibocom offers this information as a service to its customers to support application and engineering efforts that use the products designed by Fibocom The information provided is based upon requirements specifically provided to Fibocom by the customers All specifications supplied herein are subject to change Disclosure of this information to other parties is prohibited without the written consent of Fibocom Copyright Copy Reproduce Distribute and or Edit of this document or part of it as well as utilization of its contents and communication thereof to others without express authorization are prohibited Offenders will be held liable for payment of damages All rights created by patent grant or registration of a utility model or design patent are reserved Copyright 2013 Fibocom Wireless Inc All rights reserved Trademarks Notice B Fiaaocom The FIBOCOM Logo is registered by Fibocom Wireless Inc All other product or service names or logos are the property of their respective owners Copyright 2013 Fibocom Wireless Inc All rights reserved Revision History Version Date Remarks V1 0 0 2013 06 21 Initial Version V1 0 1 2013 07 31 Change M2M to OpenCPU Update some descriptions V1 0 2 2014 03 10 Add GPIO application spec and need specially cho
7. TS CTS tm Pin 20 UART1_RTS All flow control handshakes are supported hardware or none The UART1 is configured to be115200bps 8 data bits 1 stop bit and no parity 2 2 2 UART2 UART2 communicates with outside Pin No Signal Name Description Feature 40 UART2_TXD Module Transmitted Data G510 Transmitted Data 39 UART2_RXD Module Received Data G510 Received Data Recommended connection Application MCU Direction Module TXD AAA Pin 39 UART2_RXD RXD E Pin 40 UART2_TXD The UART2 is configured to be115200bps 8 data bits 1 stop bit and no parity 2 2 3 OpenCPU Application Note for VART1 amp UART2 Interface Function Input Parameter Void sys_uart_output INT32 id UINT8 buff lt id gt UART ID 0 means UART1 1 means UART2 lt buff gt data pointer lt len gt data length G510 Hardware OpenCPU User Manual Page 8 of 14 Bs FIBOCOM UINT16 len Void uart_input lt uid gt UART ID lt data gt UART data pointer INT32 uid lt len gt UART data length UINT8 data UINT16 len You can set the baud rate of these two UART ports by API interface Interface Function Input Parameter INT32 sys_set lt id gt operation ID lt arg gt parameter pointer GAPP_OPTION_ID_T id lt len gt parameter length Void arg UINT16 len Note Do not use AT command to set baud rate 2 2 4 HOST UART
8. ose and use V1 0 3 2014 04 14 Add OpenCPU modules and INT interface function G510 Hardware OpenCPU User Manual Page 2 of 14 Bs FIBOCOM Applicability Table No Type Note 1 G510 Q50 00 Standard model it can be upgraded by integrated software 2 G510 Q50 90 Integrated model number the external label is different from other models 3 G510S Q50 00 CE certification included it can be upgraded by integrated software G510 Hardware OpenCPU User Manual Page 3 of 14 Bs FIBOCOM Contents MR NN 5 A RENA 5 PASA a a a E a a 6 2 Hardware Desidia oree raa A A 7 ZA Power Om Olalla e an e E R A E E R 7 2 1 1 During Om the Module ercon ins OA EEE i 7 2 1 2 Turning off the Module sirimiri a a EE E RS E EATER 7 22 UAR a E E E E E E E E AR 7 22 TUART o ER E E E E E E E E EAR N E 7 222 UART AA a e a E S E 8 2 2 3 OpenCPU Application Note for VUART1 amp UART 2 ee ccccscsseseeseseeceseeeeseseeseeeeseseeseeeeseeessesesaees 8 22 A ROS UA sacos 9 2 2 5 OpenCPU Application Note for HOST UART ccccccccccsseseseeseeeseeseseeeeecsecscsesseseeseseeseeensesesees 9 2 2 6 OpenCPU Application Note for Virtual UART cccccccceseseesesceseeseeeseeeeseeeesesseseeseseneseenesseeees 10 2 3 Sleep Mode iia 10 2 4 GPIO IMA AAA 10 ZO INT INterace natacion T E E 13 A 0 9 grin ro ao ee A 14 G510 Hardware OpenCPU User Manual Page 4 of 14 Bs FIBOCOM 1 Preface 1 1 Overview Definition
9. se do not use any operation or AT command which will cause the module power off 2 2 UART For Standard module it has 3 UART ports UART1 is a completely independent 4 wire serial bus interface This is the main UART UART2 is a 2 wire serial bus interface HOST UART is a debug UART which is used for downloading calibrating trace and so on it doesn t support any AT command For OpenCPU module it has one more UART which is Virtual UART it is used for sending AT command from Customer software to module Module firmware 2 2 1 UART1 UART1 is used for all the communications with module it can program upgrade Module firmware and G510 Hardware OpenCPU User Manual Page 7 of 14 Bs FIBOCOM Customer software The module is defined as a DCE device and the user application is defined as the DTE device These definitions apply for the UART signals naming conventions and the direction of data flow as described in the following tables Pin No Signal Name Description Notes 19 UART1_TXD Module Transmitted Data G510 Transmitted Data 18 UART1_RXD Module Received Data G510 Received Data 21 UART1_CTS Module Clear To Send G510 Switch To Received Mode 20 UART1_RTS Request To Send G510 Notice DTE Requested To Send Recommended connection Application MCU Direction Module TXD E Pin 18 UART1_RXD RXD A Pin 19 UART1_TXD RTS A Pin 21 UART1_C
10. status means the current level high UINT8 level or low O means low level 1 means high level 2 6 Watchdog OpenCPU module supports watchdog function which avoid module crashes or other abnormal situation occurs This function is disabled by default you can invoke API to enable it and feed the dog For details please refer to G5 Family OpenCPU API User Manual G510 Hardware OpenCPU User Manual Page 14 of 14