Home
        GK-604 Inclinometer Readout User`s Manual
         Contents
1.    E OKON The World Leader in Vibrating Wire Technology    48 Spencer Street   Lebanon  NH 03766  USA  Tel  603  448  1562   Fax  603  448 3216   F mail  geokon geokon com  http   www geokon com       GK 604  Inclinometer Readout    User   s Manual    No part of this instruction manual may be reproduced  by any means  without the written consent of Geokon  Inc     The information contained herein is believed to be accurate and reliable  However  Geokon  Inc  assumes no responsibility  for errors  omissions or misinterpretation  The information herein is subject to change without notification     Copyright    2012 by Geokon  Inc    Doc Rev Initial  1 2012     Warranty Statement       Geokon  Inc  warrants its products to be free of defects in materials and workmanship  under normal  use and service for a period of 13 months from date of purchase  If the unit should malfunction  it  must be returned to the factory for evaluation  freight prepaid  Upon examination by Geokon  if the  unit is found to be defective  it will be repaired or replaced at no charge  However  the WARRANTY  is VOID if the unit shows evidence of having been tampered with or shows evidence of being  damaged as a result of excessive corrosion or current  heat  moisture or vibration  improper  specification  misapplication  misuse or other operating conditions outside of Geokon s control   Components which wear or which are damaged by misuse are not warranted  This includes fuses and    batteries     Geokon m
2.  Exiting the Program    The  Close Window   X  in the upper left corner of the display screen does not stop the program   it only pauses the operation and hides the program  This can be a problem as it leaves the  Bluetooth connection active  eventually the remote will time out and shut off   This option retains  any readings that haven t been saved to a file  simply re activate the GK 604 program and pick  up where you left off      Selecting the    Readings    Exit    option from the main screen forces everything off and ensures a  clean start the next time  This option will cause readings to be lost if they have not been  saved to a file  see section 2 2  figures 8 and 9 for information regarding saving data      3  Configuring Holes  Probes  and Projects  Parameters such as English metric units  initial level of hole  and gage factors can be adjusted to  meet user   s needs and the specifications of the probe  The software currently supports 2 different    probe types  up to 12 different probe configurations and as many hole configurations as the Field PC  can store in memory  All these can be adjusted using 3 options on the System menu     3 1 Hole Configuration    Select System   Hole Configuration and the screen depicted in figure 11 will be displayed       Hole ID se   GK 604 Inclinometi a  rE 349 lok    Tap on the keyboard icon  bottom of the screen   to bring up the on screen keyboard  Use it to edit  the Hole ID  name        Probe Number Probe Number    Select the 
3. L Ta CQUUIROS ah ays ws se arevsnsaeateiatindec E a steep setae bated eensaatateatecebaen aan die nantes ieee  1  1 2 Before using the GK 604 Readout software           ccccccssseccceesececceeececccaeseceeauseceeeeeeceesenceesenseeetees 2   2  Operati   N dicsiscscdessadecaaasessveswnans caswergeveamacencsdess ENE AANE A ETa 3  2 4     ESKADIISHINE CONTACT WITN ENE FOMOLCS uyursan aA Ta S E TN 3  2 2 Using the GK 604 Readout SoftWare Skea isacccassanciedslsanc sails e A aa ea Oi 5  Zed    EXITING TNCs FORLANI aae aa T T EAT 8   3  Configuring Holes  Probes  and Proje cts            ccsscssccsscssccsscssccsscssssscssceees 9  5 J  Hole CONTIG UPATION ateatiseses Malsleeae a a a a Na 9  3 2 Probe COMMBUPAUIO Mc siepscndcatas mira snakiecbacapaica oe salaried weg oa teaea oasdeeee na keehudevaeaen as twer sania moon emia beastiee  10  33 Project COMP SUL AU Onsa asa manatee dau a eaine eRe O eat 10  SA EC OMDASS PROD C cisi a ne aE tin Ganenteeanasabip angele S EAE ETT 11   4  Files  Folders  Transferring Data  Software Updates              sscssscssscsscesees 12  ALFE NIRS COE seastecitewecce ste es A E O A EN 12  42 Upda tine FILMI Wale eaea A de a cutenie es aceae 13    4 3 Installing updated GK 604 Readout SoOftware          ccccccscccssscccceecsceeecsceneceeenseeeeueceseueceeeeseeeneeees 13    Table of Figures     Figure 1   Remote Module  mounted in reel  and Archer Field PC             cccccceeccceseesecseeeeenseseeeseseeeeeees 1  Heure 2   Man S CK CIN 55 cet caicsiccerta
4. Probe Number  or name  from the drop noon   down list  This associates a hole with a particular AEE  probe  Pressing    Options    takes you directly to Starting Level  the Probe Configuration screen  see section 3 2  1o0 qdq0000     Starting Level Interval  a 2 Feet    Using the on screen keyboard  enter a value for    the initial level of the survey for this hole     0 5 meters         Interval Save  Tap the radio button corresponding to the interval  that will be used for the survey Cancel    Save    Readings Ea System  The configuration should be saved  A file will be  created using the Hole ID name   Figure 11   Hole Configuration    Open    Press    Open    to view and select any previously saved hole configurations  see figure 12              GK 604 Inclinometi oF a  4 08    Folder   GK604 Holes       10 19    62b      IHO1 GK60    10 19    60b       Figure 12  Hole Configuration File Selection    10    3 2 Probe Configuration    Select System   Probe Configuration and the screen depicted in figure 13 will be displayed       Probe Number        GK 604 Inclinomeli gt     4 28 lok  Use the drop down list to select 1 of 12 probes ee A o    Edit probe name      Edit probe name Probe  limit to 5  Use the on screen keyboard to enter a friendly Number  characters   name A Gage Factor B Gage Factor   1 000000 1 000000     A and B Channel Gage Factors i   Using the on screen keyboard  enter appropriate  Zero Shift B zero Shift    E IE      numbers for the 2 gage factors  see th
5. aise the value to skip file names       OK Cancel  Tapping    OK    updates the current values and saves  the information to the auto configuration file     Readings   System       Figure 14   Project Configuration    11    3 4 Compass Probe    Select System   Compass Probe and the dialog box  depicted in figure 15 will be displayed     Using a compass probe     Using a compass  spiral   probe     Figure 15   Compass Probe Confirm       o Selecting Yes will rescale the software to       GK 604 Inclinometi   7   8 44 X  properly display 0 360 degrees on the Live  Readings screen  The    type    on the Main  Screen will reflect that a Compass Probe has    been selected  see figure 16   G    The software is designed to work only OKON    with the Geokon 6005 3 Spiral Indicator  Probe  Inclinometer Readout    m      Only one channel  A  is read and  displayed on the Live Readings screen   see figure 17   Only the A1 readings are  stored in the data file     Probe Status  Connected    Type  Compass Probe        Todiscontinue the use of Compass Probes   you must exit the Live Readings screen   select System    gt Compass Probe again  and    Bore Hole  IHO1  answer No at the prompt  see figure 15   Readings EJ System       Figure 16   Compass Probe selected    ee a ee         GK 604 Inclinometi gv     9 01 ok   1  4   Data Set Switch Set    wa 100 0m 3    fis  Bl    A1 az   Hole ID  THO1    Readings Hs   System  Figure 17   Live Compass Readings       12    4  Files  Folders  Transfe
6. anufactures scientific instruments whose misuse is potentially dangerous  The instruments  are intended to be installed and used only by qualified personnel  There are no warranties except as  stated herein  There are no other warranties  expressed or implied  including but not limited to the  implied warranties of merchantability and of fitness for a particular purpose  Geokon  Inc  is not  responsible for any damages or losses caused to other equipment  whether direct  indirect  incidental   special or consequential which the purchaser may experience as a result of the installation or use of  the product  The buyer s sole remedy for any breach of this agreement by Geokon  Inc  or any breach  of any warranty by Geokon  Inc  shall not exceed the purchase price paid by the purchaser to Geokon   Inc  for the unit or units  or equipment directly affected by such breach  Under no circumstances will    Geokon reimburse the claimant for loss incurred in removing and or reinstalling equipment     Every precaution for accuracy has been taken in the preparation of manuals and or software  however   Geokon  Inc  neither assumes responsibility for any omissions or errors that may appear nor assumes  liability for any damages or losses that result from the use of the products in accordance with the    information contained in the manual or software     Table of Contents     1  MER OOUCTION ii csscssccacssncussesvecauohnoascliscsedsameuscecumeedcanaesseacseccamesswoutcacseiadeencueas 1  R
7. clinometi gt 21 18  X    EOKON    Inclnometer Readout    Probe Status  Connected    Type  Inclinometer Probe  Save to File    Clear Readings  Bore Hole  IHO1 Exit  Readings e System       Figure 5   Probe Connected Figure 6   Readings Menu    The    Live Readings    screen appears as in figure 7     e Readings are continuously updated from the remote  The    Data Set    always starts with    Set  1    but can be switched at any time to    Set 2     usually after rotating the probe 180 degrees      e Atthe start of a survey  the    level    is set to the     Starting Level    configured for a particular hole  3     GK 604 Inclinometi     PE 1 49    ok  Pressing the    Record    button  with a finger or 7  tap of the stylus  records that set of A amp B values  and automatically changes the    level     on Data set 1  screen  by the an amount based on the hole 1 00 Om  configuration  see section 3 1   The    Record    Level a    option can also be activated by pressing the     Enter    key on the keypad     e Be sure to move the probe to the new level and  wait for the readings to stabilize before    recording the next reading  vs  e A    beep    sound should be heard  confirming that              the reading has been stored  If no beep is Hole ID   heard  tap the    volume    control at the top of the  screen and adjust the volume     e At any point you can scroll the    level    using the P CESTE E o System  Up Down buttons on the screen and view data  stored and checksums  lo
8. dacacimaciestaeea de qiin vaca vaner la T ve dainua N EEEa 5  FICUbe SCO MMECEION EEE OF seceuscneecaas sve soictenauabaed saicew asta vesoued sevens E E 5  FICUCE 4   System WISI eects icuicerecaaeniactik neces airadesten saa apeba a EET eats eee desea sages ee a aetaiae se ee NES 5  FIgUKe 5    POD E Connec edins EAA Sete A 6  FICUTEG   REAGINGS MENU neronen re EE Cad tana ienosetecaaaesanoustueneoieee 6  Fisube 7   Live REAGIneS SChOCM enoni a earn ctinctaectian bie E iodine 6  Heure s  Save data CONN oenas a E EA 7  Figure 9   Auto increment Save            ssssssessesesssesesrrssssrsseseorrssresesessresoseereseesreresreseorrerosesrrssoseesesseseeseeeess 7  Figure 104File Save AS SCh EC i ioninrnin a O AE NE 7  Heure tie HOle CONSUL AU ON eit a a a a tcieawieaah 9  Figure 12  Hole Configuration File  SelectioNaiinn a ecias caw Sata Pastas ena 9  FICUPC 13   PROBE CONT SULALION eaa eieovaniavecsonitnacsadene 10  Ficuire  14  PPOject Connora Oiee nS S A SN 10  Fere 15 26 Ompass  PFODe CONTIEM anei a N 11  Heure 16   Compass PTODE selected nri a a a Taa 11    Figure 17 LIVE Compass REdAdINE Sonserina  11    1  Introduction    The GK 604 is made up of two components    e the readout which is composed of an Archer Field PC running the GK 604 Inclinometer Readout  software   e the GK 604 remote module which is directly connected to the inclinometer probe and is housed in  a weather proof enclosure       Figure 1   Remote Module  mounted in reel   Archer Field PC and Carrying Ca
9. done before it leaves the factory  Follow the steps    below to ensure the    partnership    with the remote is established before using the readout  software     il    2     Use the Bluetooth Settings Manager on the Archer Field PC to set up the link to the remote  Read  about setting up a Bluetooth    partnership    in Chapter 9 of the Field PC   s Reference Guide     Several ways to start the    Bluetooth Manager       Start 3  ME 9 47    Wednecday M7 e  2    Connectivity    J  ither the Internet or work   mf connection in Settings     Once in the Bluetooth Settings Manager  click on the    Mode    tab and  then make sure that the box next to    Turn on Bluetooth    is checked     Click on the    Devices    tab  If it shows a    Geokon    device  name will  start with    GK    and contain the remote   s serial number   go to the next      G Windows Media              1 i  gt  2 9       Today   Settings e     9 55 X    E Calendar EE ZO  3 T    EB Contacts   Beam Connections  Internet Explorer    A Messaging       T   File Explorer  Fd Excel Mobile    a Mobile    _    Ta Programs    F Settings Personal   System Connections        Help Ea    7   Settings    Bluetooth    Turn on Bluetooth     C   Make this device visible to other  devices    To connect to a device  click on the Devices  tab below     Fa    7   Settings    Bluetooth    step  Otherwise turn on the remote module  should see a flashing blue   Tap Add new device to search for other    indicator on the remote  and s
10. e  Inclinometer Probe manual and Calibration sheet for    more information  Press Update to save current  changes in memory  OK saves to    File     A and B Channel Zero Shift    To compensate for any offset at zero enter    appropriate values for the Zero Shift values  see the oo  Inclinometer Probe manual and Calibration sheet for    more information        Readings   System an    Update  Tapping    Update    causes the information to be Figure 13   Probe Configuration    temporarily used for the current set of readings   you ll see the effect when you go to    Live Readings    and the readings which are saved in this  session           OK  Tapping    OK    updates the current session and saves the information to the probe  configuration file  so it can be used in future sessions      3 3 Project Configuration  Select System   Project Configuration and the screen PA eaa S  tatters Fie Bi iar     depicted in figure 14 will be displayed       Project Name Project Name  can be changed and is stored in the data file  Project      Auto Increment File    The 3 digit value in this entry is added as a suffix to Auto o  RE RUnDEr wil be  data file names automatically if the Auto Incr  Increment Fie ladded to the file  Enabled box is checked  The 3 digit value is 001 name if enabled   automatically adjusted after every file is saved and    the value shown is the current value to be used  You Auto Incr  Enabled  can lower this value to force overwrites of previously  saved files  or r
11. elect    Add new device           Bluetooth devices  Tap on a device to modify  its settings     Poseemos  Fa          Settings    4  When a suitable remote is discovered  highlight the device and click Next  Sciet2BiuetoothDevice __     Select a device to connect with and tap  Next        Cancel   Next    5  A prompt will be displayed for a password  enter    default    and press Next RD  again  If a partnership with the device is successfully established the  screen will momentarily display the prompt to the right and then return to Enter a passcode to establish a secure  the Bluetooth Devices screen  connection with Gk6041141573     Press Next    to continue if a passcode is not  required     Device Added    Your Pocket PC has connected with  GK6041141573     a  Advanced       6  Click on the COM Ports tab  If the    Geokon    device is already assigned ne   Settings E  4    ok    to a COM Port  the partnership process is finished  If not  select    New    Outgoing Port    and select an available COM port  COM5 is the default   AOE EE E D A sesh    Be sure to remember the number of the COM port as you may have to PEETS AEAT aeons a eer Rene     select it later in the readout software  see section 2 2   GK6041141573  COM2   New Outgoing Port       2 2 Using the GK 604 Readout Software    The readout software can be launched by tapping the Start button and selecting it from the drop  down list or clicking on Programs and then clicking the G icon  After launch the main  openi
12. ion is available for free from the Microsoft site   www microsoft com and search for    Active Sync download      Once installed  generally  requires a reboot   simply connect the USB cable from the Field PC and then open    My  Computer    on the XP machine and see a    PDA    entry under drives  Just double click on it  to see the folders in the Field PC        If you are using Windows Vista or Windows 7  they include software called Windows Mobile  Device Center and you should be able to immediately connect the Field PC and see it in  the    Computer    window     13    It is not necessary to set up any    syncing    options although it can easily be accomplished   Another Bluetooth partnership can also be set up from your desktop laptop  assuming they have  Bluetooth modules  to the Field PC and transfer files that way     All of these options  and more  are described in the Field PC   s Reference Guide     4 2 Updating Firmware    This section describes how to download new firmware revisions to the GK 604 Remote Module   If a firmware update is needed  new update files  GK604_RFW S19  are typically available from  Geokon via email or by downloading from the Geokon web site  The steps below describe the  firmware update procedure     e This file needs to be transferred to the  My Documents folder of the Field PC  using any  strategy described above      e Turn on the remote and make sure its battery is charged  or it is powered externally   A  power supply interruption du
13. ng   screen is displayed  see figure 2      re   GK 604 Inclinome Er m   11 15 X    EOKON  Inclinometer Readout    Probe Status  Mo Contact  Click on System  gt Connect   to retry     Bore Hole  IHO1  Readings Fd System       Figure 2   Main screen    If at launch  the application displays the error shown in figure 3  then the following options should   be considered    e Make sure the remote is turned on  blue light blinking     e Select the    System    option and    Connect to Remote    again  if no previous connection   assumes COMB has been set up as an outgoing port in the Bluetooth Settings Manager  or  select the    Alternate Connect    option  see figure 4  and pick the COM port previously  established in section 2 1                Hole Configuration  Probe Configuration  Project Configuration    Compass Probe  Unable to connect  Be    sure that selected COM Syst  port is set as Outgoing    Connect to Remote  Alternate Connect b    type in  Start  gt  Settings   gt  onnectio  n   gt  BlueTooth   COM Ports    Update Firmware  About GE 604    aid       Figure 3   Connection Error Figure 4   System Menu    A successful connection is reflected in the Main Screen status as in figure 5  At this point  readings can be taken by clicking    Readings   Live Readings     see figure 6   After an initial  connection  subsequent connections should happen automatically provided the remote is  powered on before launching the GK 604 Inclinometer Readout application          GK 604 In
14. ring a firmware update will make it more difficult to complete the  update in the field and may require sending the unit back to Geokon     e With the GK 604 readout software running  select System    Update Firmware and follow  the on screen instructions  It takes several minutes to complete the update  so don t turn off  the Field PC or the remote unit     4 3 Installing updated GK 604 Readout Software    As new versions of the GK 604 Inclinometer Readout software become available they will be  posted to Geokon   s web site  The installation will overwrite the old program  but will not destroy  any of your saved data or configuration files  If in doubt  and as a matter of good computer  technique  take the time to back up critical data and configuration files BEFORE installing the new  software     e This file needs to be transferred to the root     folder or the  My Documents folder of the Field  PC  using any strategy described in section 4 1      e On the Field PC  tap the Start button and then select File Explorer  Navigate to the location  of the setup file and tap it     e Confirm that you want to install the new program and follow any on screen instructions     After the installation is complete you should be able to simply launch the GK 604 software from  the start menu     
15. rring Data  Software Updates    There are several types of files in use with this software  hole configuration files  probe configuration  files  GTilt data files  firmware update  and setup files  The software assumes the following     Purpose Assumed Folder Filename File  Extension   Hole  My Documents GK604_Holes  User specified in the Hole TXT   Configuration Configuration window    Probe  My Documents GK604_Probes  GK604PROB   Configuration    M File e Documents            hanni Increment Daanan Documents  Daaa  Parameters    GTilt Data files  My Documents  User specified when the   saved readings  Save Readings option is  selected     Firmware Update    My Documents  GK604_RFW   for remote unit     Installation File   GK604 Setup   for the GK 604  readout software     root folder        Table 1     Folder paths and File Names    4 1 File Transfer    In general  the only files that will have to be transferred are the GTilt data files  although  archiving the others on a    master    PC is recommended  In either case this is easily  accomplished several different ways  Connecting the Field PC to a desktop or laptop PC using  the supplied USB cable  Type A to mini B  is straight forward and allows the user to view the  Field PC   s storage as a flash drive on the desktop laptop  you can then simply drag the files  around to any folder on the desktop laptop        If you are using Windows XP you will need to download and install the program      ActiveSync     This applicat
16. se    The two components communicate wirelessly using Bluetooth     a reliable digital communications  solution  This simplifies the handling of the system in the field as well as simplifying the transfer of  data to your PC workstation for final analysis     1 1 Features    Rugged  general purpose  reliable readout based on an Archer Field PC   e all the benefits of a Windows compatible device  Windows file system  RS 232  USB and  wireless connectivity     e long battery life  e ease of use    Lightweight and simple remote unit   e Lithium battery  8   hours of continuous use     e one button operation  automatic power down when Bluetooth connection is dropped or after  several minutes of inactivity    e rugged  e reliable connection to standard inclinometer probes  e firmware upgradeable in the field    1 2 Before using the GK 604 Readout software    The readout software runs as an application under Windows Mobile 5 or 6 operating system  installed on an Archer Field PC       Please familiarize yourself with the Field PC  see the included CD Reference Manual  and  the Windows Mobile OS       It is assumed in the instructions below that you can launch applications from the Start button  including File Explorer and the Bluetooth Settings manager       tis assumed that you can tap the keyboard icon as needed and use the on screen keyboard  to enter text and numbers     2  Operation    2 1 Establishing contact with the remote     This only has to be done once and is typically 
17. wer half of the screen   Figure 7   Live Readings Screen       e When done taking readings  press Done  You will be given the option to save the reading to        a file  see figure 8       ETT a ae E  Level Gure  E  o Even if you select No  the readings are not lost   aioe Sure       and you can choose to save later using the     Readings   Save to File    option from the main   A  screen  The Readings will only change if you go  back into Live Readings  and record new ones   Ei  over the old  or select    Readings   Clear    5   l    a  0  Readings    from the main screen   Ble Bee J   Figure 8   Save data confirm  o If Yes is selected  you then will be given the choice of saving with the auto increment  suffix on the standard filename  see figure 9   Selecting Yes again causes the save  operation to be carried out using a filename of aa t  the form   Hole_ID  3 digit Autolncr_Suffix   GKN Level using    i  o If you select No  to the auto incrementing option    Save using auto     you will be shown the standard File Save As      incrementing filename   screen and you can modify the file name to    anything you choose  Use the stylus to clickon    6          the keyboard icon  bottom  and make the  changes you desire  see figure 10      bee emem eee ewe ewww www ewww ewww we we ww wm we we ew ww ew ew ew ew ew ew Ww    Figure 9   Auto increment save    se   GK 604 Inclinometi 4      3 00    Mame  IHO100O1  Folder   Type     Location     Figure 10   File Save As Screen    2 3
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
UPS SYSTEM Communication Manual Network  Verbatim DVD+RW Matt Silver  Genesys Series - Daitron[ダイトエレクトロン株式会社]  Bulletin d`information - L`Ardoise  OPEN SYSTEMS® Accounting Software Fixed Assets User`s Manual  ヘッジトリマー  Paquete de 3 calculadoras transparentes 65  MH-C2 HYDRAPAK  Chapter 4  Stow CC813H20 Chainsaw User Manual    Copyright © All rights reserved. 