Home
PowerScan™ PM9500 Family
Contents
1. If Datalogic determines that a product has defects in material or workmanship Datalogic shall at its sole option repair or replace the product without additional charge for parts and labor or cred it or refund the defective products duly returned to Datalogic To perform repairs Datalogic may use new or reconditioned parts components subassemblies or products that have been tested as meeting applicable specifications for equivalent new material and products Customer will allow Datalogic to scrap all parts re moved from the repaired product The warranty period shall ex tend from the date of shipment from Datalogic for the duration published by Datalogic for the product at the time of purchase Warranty period Datalogic warrants repaired hardware devices against defects in workmanship and materials on the repaired assembly for a 90 day period starting from the date of shipment of the repaired product from Datalogic or until the expiration of the original warranty period whichever is longer Datalogic does not guarantee and it is not responsible for the maintenance of damage to or loss of configurations data and applications on the repaired units and at its sole discretion can return the units in the factory default configuration or with any software or firmware update available at the time of the repair other than the firm ware or software installed during the manufacture of the prod uct Customer accepts responsibility t
2. Downloads Manuals amp Documentation Data Sheets Product Catalogues etc Contact Us Information Request Form and Sales amp Service Network Quick Reference Guide 35 Hex Numeric Keypad Hex Numeric Keypad Use the barcodes that follow to enter numbers or alpha characters as you would select characters from a keypad 36 PowerScan PM9500 Hex Numeric Keypad Hex Numeric Keypad continued Quick Reference Guide 37 Hex Numeric Keypad Hex Numeric Keypad continued E ERRE 38 PowerScan PM9500 DATALOGIC DECLARATION OF CONFORMITY EC 101 C Datalogic ADC Srl Via S Vitalino 13 ui 13 Lippo di Calderara di Reno BO 40012 Italy 5 di ag 1 di La presente dichiarazione di conformit rilasciata sotto la responsabilit esclusiva di Datalogic ADC Srl per This Declaration of Conformity is issued under the sole responsibility of Datalogic ADC Srl for Cette d claration de conformit est tablie sous la seule responsabilit de Datalogic Srl pour Diese Konformitatserklarung wird unter der alleinigen Verantwortung des Datalogic ADC Srl erteilt f r Esta declaraci n de conformidad se expide bajo la exclusiva responsabilidad de Datalogic ADC Srl para PowerScan PM9500 Cordless Barcode Reader BC9XY0 433 Cordless Base Station Charger e tutti i suoi modelli and all its models et tous ses mod les und seine Modelle y todos sus modelos sono conformi alle Di
3. DATALOGIC PowerScan PM9500 Family Industrial Cordless Handheld Area Imager Bar Code Reader Quick Reference Guide Datalogic ADC Inc 959 Terry Street Eugene OR 97402 USA Telephone 541 683 5700 Fax 541 345 7140 2013 2014 Datalogic Inc An Unpublished Work All rights reserved No part of the con tents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic ADC Inc or its subsidiaries or affiliates Datalogic or Datalogic ADC Owners of Datalogic products are hereby granted a non exclusive revocable license to reproduce and transmit this documentation for the purchaser s own internal business purposes Purchaser shall not remove or alter any proprietary notices including copyright notices contained in this docu mentation and shall ensure that all notices appear on any reproductions of the documentation Should future revisions of this manual be published you can acquire printed versions by contacting your Datalogic repre sentative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like to make comments or suggestions about this or other Data logic publications please let us know via the Contact Data logic page Disclaimer Datalogic has taken reasonable measures to p
4. 2 modify the Datalogic Product so that it becomes non infringing 3 replace the Datalogic Product with an equivalent product not subject to such claim or 4 provide End User an opportunity to return the Datalogic Product and receive a refund of the purchase price paid less a reasonable allowance for use 7 3 Datalogic shall have no liability to End User for claims of infringement based upon 1 the use of any Datalogic Product in combination with any product which Datalogic has not either furnished or authorized for use with such Dat alogic Product 2 the use of any Datalogic Product designed manufactured or modified to the specifications of End User or 3 End User s modification of the Datalogic Product without written authorization from Datalogic 7 4 THE FOREGOING STATES DATALOGICS COMPLETE AND ENTIRE OBLIGATION CONCERNING CLAIMS OF PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY INFRINGEMENT CANCELS AND SUPERCEDES ANY PRIOR AGREE MENTS WHETHER ORAL OR WRITTEN BETWEEN THE PARTIES CONCERNING SUCH CLAIMS AND WILL NOT BE MODIFIED OR AMENDED BY ANY PAST CON TEMPORANEOUS OR FUTURE AGREEMENTS OR DEALINGS BETWEEN THE PARTIES WHETHER ORAL OR WRITTEN EXCEPT AS SET FORTH IN A FUTURE WRITING SIGNED BY BOTH PARTIES 8 Limitation Of Liability EXCEPT AS PROVIDED IN SECTION 7 DATALOGIC SHALL NOT BE LIABLE FOR ANY CLAIMS AGAINST END USER BY ANY OTHER PARTY IN NO EVENT SHALL DATA LOGICS LIABILITY FOR DAMAGES IF ANY WHETHER BASED UPON
5. C temperature range Use only the authorized power supplies bat tery pack chargers and docks supplied by your Datalogic reseller The use of any other power supplies can damage the device and void your warranty Do not disassemble or modify the battery The battery contains safety and protection devices which if damaged may cause the battery to generate heat explode or ignite Do not place the battery in or near fire on stoves or other high temperature locations Do not place the battery in direct sunlight or use or store the battery inside cars in hot weather Doing so may cause the battery to generate heat explode or ignite Using the battery in this manner may also result in a loss of performance and a shortened life expectancy Do not place the battery in microwave ovens high pressure containers or on induction cookware Immediately discontinue use of the battery if while using charging or storing the bat tery the battery emits an unusual smell feels hot changes color or shape or appears abnormal in any other way PowerScan PM9500 Installing the Battery Pack Do not replace the battery pack when the device is turned on Do not remove or damage the battery pack s label CAUTION po not use the battery pack if it is damaged in any part Battery pack usage by children should be supervised As with other types of batteries Lithium lon LI batteries will lose capacity over time Capacity deterio
6. Good Read successfully Good Read quency volume Beep scanned by the When to Indi tonal setting reader Cate and duration seethe PRGfor upon a success information ful label scan Quick Reference Guide 17 LED and Beeper Indications INDICATION DESCRIPTION LED BEEPER Upon success ful read of a Green Spot label the soft flashes ware turns the N A N A momentarily green spot on for the time specified Blue light flashes 2 times N A P ES when updating Except when in sleep mode or when a Good Read LED Duration other than 00 is selected Table 3 Error Indicators INDICATION DESCRIPTION LED BEEPER The reader is try Link Attempt ingtolinktothe Slow Flashes N A base Reader and Base Configuration are AUS Fast Flashes N A Alignment parameters con figuration 3 beeps of descending The reader has Unlink unlinked from the base frequency There is an error Reader sounds ROM Failure the readers Flashes one error beep software pro at highest vol gramming ume 18 PowerScan PM9500 The reader has 3 beeps of Link successfully N A ascending fre linked to the base quency LED and Beeper Indications Reader chirps Indicates that a six times at the host connection highest fre is not estab quency and lished current vol Limited Scan ning Label Read ume The reader has been disabled by the host The LED blinks continuously Quick Re
7. 9 operating sara 10 CAI e lea 10 Moton Aiming COMIN os 12 a RR 12 Multiple Label Reading secos mniwie 13 Technical SOS CINE AE ONS tia 13 LED and Beeper EE 17 iig rain 21 E ooo e 22 AAPA 23 Statement of Agency Compliance ii 23 Imager Eco pam m 26 nat E 26 WEEE SEBUBITIBIDE nro 31 Datalogic ADC Limited Factory Warranty ii 32 Ergonomic Recommendations 34 and ana aiani a 35 SSRI Keypad acilia 36 Quick Reference Guide i NOTES PowerScan PM9500 Datalogic ADC Inc PowerScan 9500 PRODUCT SERIES END USER LICENSE AGREEMENT Notice to End User The Datalogic Product you have acquired contains embedded Software which is integral to the product s operation This Software is being pro vided to you under license subject to the terms and conditions of this Agreement If you use the Datalogic Product you will be deemed to have accepted the terms and conditions of this Agreement If you do not intend to be bound to the terms of this Agreement Datalogic is not willing to license the Software to you you may not use the Datalogic Product or the Software and you must contact the party from whom you acquired the Datalogic Product for instructions This End User Software License Agreement Agreement is a legally binding agreement governing the licensing of the Software and Documentation by Data logic ADC Inc and its Affiliates Datalogic to the entity or person w
8. CONTRACT TORT INCLUDING NEGLIGENCE PRODUCT LIABILITY STRICT LIABILITY WAR RANTY OR ANY OTHER BASIS EXCEED THE PRICE OR FEE PAID BY END USER FOR THE DATALOGIC PRODUCT UNDER NO CIRCUMSTANCES SHALL DATALOGIC BE LIABLE TO END USER OR ANY THIRD PARTY FOR LOST PROFITS LOST DATA INTERRUPTION OF BUSINESS OR SERVICE OR FOR ANY OTHER SPECIAL CONSE QUENTIAL CONTINGENT INDIRECT INCIDENTAL PUNITIVE EXEMPLARY OR OTHER SIMILAR DAMAGES EVEN IF DATALOGIC HAS BEEN ADVISED OF THE POS SIBILITY OF SUCH DAMAGES 9 Government Restricted Rights International Use 9 1 Use duplication or disclosure of the Software by the U S Government is sub ject to the restrictions for computer software developed at private expense as set forth in the U S Federal Acquisition Regulations at FAR 52 227 14 g or 52 227 19 or in the Rights in Technical Data and Computer Software clause at DFARS 252 227 7013 c 1 ii whichever is applicable 9 2 If End User is using the Datalogic Product outside of the United States End User must comply with the applicable local laws of the country in which the Datalogic Product is used with U S export control laws and with the English language version of this Agreement The provisions of the United Nations Convention on International Sale of Goods shall not apply to this Agreement 10 Termination 10 1Either party may terminate this Agreement or any license granted under this Agreement at any time upon written notice
9. ERM SHORT RANGE DEVICES SRD RADIO EQUIPMENT TO BE USED IN THE 25MHZ TO 1000MHZ FREQUENCY RANGE WITH POWER LEVELS RANGING UP TO 500MW PART 2 HARMONIZED EN COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE 3 2 OF THE R amp TTE DIRECTIVE EN 50581 SEPTEMBER 2012 TECHNICAL DOCUMENTATION FOR THE ASSESSMENT OF ELECTRI CAL AND ELECTRONIC PRODUCTS WITH RESPECT TO THE RESTRIC TION OF HAZARDOUS SUBSTANCES Lippo di Calderara RUGGERO CACIOPPO August 29th 2013 QUALITY amp RELIABILITY MANAGER EUROPE YA eco Gest DATALOGIC www datalogic com 2013 2014 Datalogic Inc All rights reserved Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Datalogic ADC Inc 959 Terry Street Eugene OR 97402 USA Telephone 1 541 683 5700 Fax 1 541 345 7140 820062314 Rev B January 2014
10. Multiple When the trigger is pulled and released scanning is activated until programmable dura tion has elapsed or the trigger has been pulled again to transition to another state Double Read Timeout pre vents undesired multiple reads while in this mode Flashing The reader flashes on and off regardless of the trigger status Always On No trigger pull is required to read a bar code Scanning is continually on If the trigger is pulled the reader acts as if it is in Trigger Single Default Mode Dou ble Read Timeout prevents undesired multiple reads while in this mode Stand Mode No trigger pull is required to read a bar code Scanning is turned on automatically when an item is placed in reader s field of view If the trigger is pulled the reader acts as if it is in Single Read mode Double Read Timeout prevents undesired multiple reads while in this mode 1 See the Product Reference Guide PRG for more information 10 PowerScan PM9500 Operating Mode Operating Mode continued ENTER EXIT PROGRAMMING MODE 4 Scan Mode Scan Mode Trigger Trigger Single Pulse Multiple m Scan Mode Scan Mode Flashing Trigger Hold Multiple Scan Mode Always On Scan Mode Stand Mode Quick Reference Guide 11 Pick Mode Motion Aiming Control This feature configures the ability of the scanner to Enable Disable the Aiming system when motion is detected Scan the Enter Exit Programming bar co
11. be repeated Press and release the trigger to hear the FRU indication code The following table describes the LED flashes beep codes associated with an error found Number of LED Flashes Corrective Action Beeps Digital PCB assistance Stace RA Contact Helpdesk for Quick Reference Guide 21 Cleaning Cleaning Exterior surfaces and scan windows exposed to spills smudges or debris require periodic cleaning to ensure best performance during scanning Use a soft dry cloth to clean the product If the product is very soiled clean it with a soft cloth moistened with a diluted non aggressive cleaning solution or diluted ethyl alcohol Do not use abrasive or aggressive cleansing agents or abrasive pads to clean scan win dows or plastics Do not spray or pour liquids directly onto the CAUTION unit 22 PowerScan PM9500 Regulatory Information Regulatory Information All models are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required Any changes or modifications to equipment not expressly approved by Datalogic could void the user s authority to operate the equipment Statement of Agency Compliance This device complies with part 15 of the FCC Rules Opera tion is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that
12. codes Wide angle Display and 4 keys keypad General Features To read a symbol or capture an image you sim ply aim the reader and pull the trigger Since the PowerScan PM9500 is a powerful omni directional reader the orientation of the sym bol is not important Omni directional Operating Thanks to powerful algorithms PowerScan PM9500 reliably decodes all major 1D linear barcodes 2D stacked codes such as PDF417 2D matrix symbols such as DataMatrix postal codes such as POSTNET PLANET The data stream acquired from decoding a symbol is rapidly sent to the host The reader is immedi ately available to read another symbol Decoding The string of a decoded code may be processed according to either a simple or advanced data formatting and be concatenated Formatting and Concatenating Quick Reference Guide 1 Autoscanning Flash Memory USA Driver License Parsing Using the PowerScan PM9500 An autoscan command causes the reader to scan continuously and to monitor the central zone of its reading area Flash technology allows you to upgrade the PowerScan PM9500 reader as new symbolo gies are Supported or as new features become available The reader can be set up to select and output a subset of data elements from USA Driver License PDF417 barcodes This feature can be enabled using either Datalogic Aladdin or the barcodes in the USA Driver License Parsing Quick Refe
13. if the other party breaches any provision of this Agreement 10 2Upon termination of this Agreement End User immediately shall cease using any nonembedded software and shall return to Datalogic or destroy all non embedded software covered by this Agreement and shall furnish Datalogic with a certificate of compliance with this provision signed by an officer or authorized representative of End User For embedded software End User agrees to sign a waiver prepared by Datalogic concerning further use of the embedded Software End User s resumed or continued use of the embedded Software after termination shall constitute End User s agreement to be bound by the terms and conditions of this Agreement for such use 11 General Provisions 11 1 Entire Agreement Amendment This document contains the entire agree ment between the parties relating to the licensing of the Software and super sedes all prior or contemporaneous agreements written or oral between the parties concerning the licensing of the Software This Agreement may not be changed amended or modified except by written document signed by Data logic Quick Reference Guide V Software Product Policy 11 2 Notice All notices required or authorized under this Agreement shall be given in writing and shall be effective when received with evidence of receipt Notices to Datalogic shall be sent to the attention of Contract Administration Datalogic ADC Inc 959 Terry Street Eugene O
14. may cause undesired operation Quick Reference Guide 23 Regulatory Information China RoHS Table of Restricted Elements Scanner SHEI 9007 9 1 1 L S Kea auto Oe HL Ej OH Je Ton GHEY LSD ES EE Y y ch 3 8 ga He E rn 11 5 Be re ch RE Ga GO EY Ll psd 38 EHA 9006 69611 L S NEMI SES AMIA ES EINER Y y da LAA ERA HH e y Dirr BLAIR E SE 0 ojx mx a unum K quiassy paeog 11541 Dau sse some e 9 ww T IA 4D s13y39 Aueudip LUNILUOJYI 6H dd payeulwoiqhjog pajeunmuolq jog 3ue eAexeH mur pea PowerScan PM9500 24 Regulatory Information China RoHS Table of Restricted Elements Base EAN 9007 E9 11 L LS Kea MGA Ge EH pA EAR MAT 5 BEIGE SY ety a T e HR ass B8 BGS Le th see EE etel A ER Ee Yel pp IE EHH QO07 E9ETT L LS Kea MGA D EL EHM SES 28 1B Wel SET SEE Y ay ch LAA EVER Ep HS Hel chk A Di Gr E Le Gp See SE O te He Ae Ae jnpo Assy VHA YAH Alquessy pieog noi Doud Wise mi 7 PEATE Leva SEL AE ge EY ES Ey A sJeuje Aueudip sj u yd q WUNILUOJYD po 6H qd pejeuiwolgAjod pareuiwuolgAjod juayenexan unmuupeo ANN pee 25 Quick Reference Guide Regulatory Information Imager Labeling Aiming System The PowerScan aiming system meets the Class 2 requirements for laser safety The laser information is locat
15. proprietary rights or 4 independently developed without access to Proprietary Information 1 4 Datalogic Product means the Datalogic Powerscan series scanner product including all embedded Software in and all Documentation related to such product which has been purchased or otherwise acquired by End User whether obtained directly or indirectly from Datalogic 1 5 Software means any software or computer programs of Datalogic or its third party licensors in machine readable form which is embedded in the Datalogic Product whether obtained directly or indirectly from Datalogic including any replacement update upgrade enhancement or modification 2 Scope Of License Granted 2 1 Datalogic grants to End User a non exclusive non transferable perpetual license to use the Software solely on the Datalogic Product in which it is embedded designated Datalogic Product in machine readable form only solely for End User s internal business purposes This Agreement does not convey ownership of the Software to End User Title to the Software shall be and remain with Datalogic or the third party from whom Datalogic has obtained a licensed right As used in this Agreement the term purchase or its equivalents when applied to the Software shall mean acquire under license End User is not entitled to receipt or use of the source code to any Software 2 2 End User shall not copy modify decompile disassemble reverse engineer or
16. the ENTER EXIT bar code again to accept your changes which exits Program ming Mode and returns the reader to normal operation Configure Other Settings Additional programming bar codes are available in the PRG to allow for customizing programming features If your installation requires different programming than the standard factory default settings refer to the PRG Resetting Product Defaults If you arent sure what programming options are in your reader or you ve changed some options and want custom factory settings restored scan the bar code below to reset the reader to initial configuration Reference the PRG for other options and a listing of standard factory settings Factory defaults are based on the interface type Be sure your reader is configured for the correct interface before scanning this label Reset Default Settings Quick Reference Guide 7 Set Date and Time Compatibility with the PowerScan 8000 family The PM9500 can be programmed to operate in a mode compatible with the PowerScan 8000 family For further details and for the relevant configuration strings and labels refer to the PRG Set Date and Time 1 Scan the Enter Exit Programming bar code below to set date and time ENTER EXIT PROGRAMMING MODE 2 Scan the Set Date bar code six digits for Year Month and Day YYMMDD from the Hex Numeric Keypad on page 36 Wei H RR Be Set Date 3 Scan Set Time six digits for Hou
17. zu richten FRANCAIS Les informations suivantes sont fournies selon les regles fix es par les autorit s internationales et se r f rent a une correcte utilisation du terminal NORMES DE SECURITE LASER Ce produit est conforme aux normes de s curit laser en vigueur a Sa date de fabrication CDRH 21 CFR 1040 et EN 60825 1 Il n est pas n cessaire d ouvrir l appareil pour l installation l utilisation ou l entretien L utilisation de proc dures ou r glages dif AN f rents de ceux donn s ici peut entra ner une dangereuse exposition lumi re laser ATTENTION sible Le produit utilise une diode laser Aucun dommage aux yeux humains n a t constat la suite d une exposition au rayon laser Eviter de regarder fixement le rayon comme toute autre source lumineuse intense telle que le soleil Eviter aussi de diriger le rayon vers les yeux d un observateur m me travers des surfaces r fl chissantes miroirs par exemple Quick Reference Guide 29 Regulatory Information ESPANOL Las informaciones siguientes son presentadas en confor midad con las disposiciones de las autoridades interna cionales y se refieren al uso correcto del terminal NORMATIVAS EST NDAR PARA LA SEGURIDAD L SER Este aparato resulta conforme a las normativas vigentes de seguridad l ser a la fecha de producci n CDRH 21 CFR 1040 y EN 60825 1 No es necesario abrir el aparato para la instalaci n la uti lizaci n o la manutenc
18. R 97402 or such other address as may be specified by Datalogic in writing 11 3 Waiver A party s failure to enforce any of the terms and conditions of this Agreement shall not prevent the party s later enforcement of such terms and conditions 11 4 Governing Law Venue This Agreement and the rights of the parties hereun der shall be governed by and construed in accordance with the laws of the State of Oregon U S A without regard to the rules governing conflicts of law The state or federal courts of the State of Oregon located in either Multnomah or Lane counties shall have exclusive jurisdiction over all matters regarding this Agreement except that Datalogic shall have the right at its absolute dis cretion to initiate proceedings in the courts of any other state country or ter ritory in which End User resides or in which any of End User s assets are located 11 5 Attorneys Fees In the event an action is brought to enforce the terms and conditions of this Agreement the prevailing party shall be entitled to reason able attorneys fees both at trial and on appeal END Software Product Policy Datalogic reserves the right to ship its products with the latest version of software firmware available This provides our customers with the very lat est in Datalogic software technology The only exception to this policy is when the buyer has a signed contract with Datalogic that clearly defines the terms and conditions for mak
19. ant to Laser Notice No 50 dated June 24 2007 Radio Features UC Wate 433MHz 910 MHz model Ing center 19 2 kb s 36 8 kb s 115 2 kb s 500 kb s default 500 kb s default Programmable Speed 100m at 500kb s 140m at 36 8kB s frequency hopping 50m at 36 8kb s fixed channel Typical Range 50m at 500kb s in open air 100m at 19 2kb s 16 PowerScan PM9500 LED and Beeper Indications 100m at 500kb s 140m at 36 8kB s frequency hopping 50m at 36 8kb s fixed channel Typical Range in open air DPM models 40m at 500kb s 80m at 19 2kb s Max number of devices per base station LED and Beeper Indications The reader s beeper sounds and its LED illuminates to indicate various functions or errors on the reader An optional Green Spot also performs useful functions The following tables list these indications One exception to the behaviors listed in the tables is that the reader s func tions are programmable and so may or may not be turned on For example certain indications such as the power up beep can be disabled using programming bar code labels Table 2 Normal Operating Indicators INDICATION DESCRIPTION LED BEEPER Reader beeps four times at highest fre quency and vol ume upon power up The reader is in the process of powering up Power up Beep LED behavior is The reader will configurable via beep once at A label has been the feature current fre
20. c service per sonnel or its authorized representatives ii any claimed defect failure or damage which Datalogic determines was caused by faulty operations improper use abuse misuse wear and tear negligence improper storage or use of parts or accessories not approved or supplied by Datalogic ili any claimed defect or damage caused by the use of prod uct with any other instrument equipment or apparatus iv any claimed defect or damage caused by the failure to provide proper maintenance including but not limited to cleaning the upper window in accordance with product manual vy any defect or damage caused by natural or man made disaster such as but not limited to fire water damage floods other natural disasters vandalism or abusive events that would cause internal and external compo nent damage or destruction of the whole unit consum able items vi any damage or malfunctioning caused by non restoring action as for example firmware or software upgrades software or hardware reconfigurations etc vii the replacement of upper window cartridge due to scratching stains or other degradation and or viii any consumable or equivalent e g cables power supply batteries keypads touch screen triggers etc No Assignment Customer may not assign or otherwise transfer its rights or obli gations under this warranty except to a purchaser or transferee of product No attempted assignment or transfer in violation
21. d 4 Intellectual Property End User acknowledges that the Software constitutes valuable trade secrets of Datalogic or Datalogic s third party licensors and that the Software is protected by intellectual property laws and treaties The license set forth in this Agreement does not transfer to End User any ownership of Datalogic s or its third party licen sors copyrights patents trademarks service marks trade secrets or other intel lectual property rights and End User shall have no right to commence any legal actions to obtain such rights End User shall not remove modify or take any other action that would obscure any copyright trademark patent marking or other intellectual property notices contained in or on the Datalogic Product 5 Proprietary Information 5 1 End User acknowledges that Proprietary Information is the confidential pro prietary and trade secret property of Datalogic and Datalogic s third party licensors and End User acquires no right or interest in any Proprietary Infor mation 5 2 End User shall not disclose provide or otherwise make available the Propri etary Information of Datalogic or its third party licensors to any person other than End User s authorized employees or agents who are under confidentiality agreement and End User shall not use the Proprietary Information other than in conjunction with use of the Datalogic Product exclusively for End User s internal business purposes End User shall take s
22. de above then either of the bar codes below 4 Motion Aiming Control Motion Aiming Control Enable Disable Pick Mode Pick Mode is a Decoding and Transmission process where bar codes that are not within the configurable distance from the center of the aiming pattern are not acknowl edged or transmitted to the host It is active only in Trigger Single mode If the scanner switches to a different Read Mode Pick Mode is automatically disabled This feature is not compatible with Multiple Labels Reading in a Volume See the PRG for more information ENTER EXIT PROGRAMMING MODE 4 Pick Mode Disable n n Pick Mode Enable 12 PowerScan PM9500 Multiple Label Reading Multiple Label Reading The reader offers a number of options for multiple label reading See the PRG or software configuration tool for descriptions of these features and programming labels Technical Specifications The following tables contain Physical and Performance Characteristics User Environment and Regulatory infor mation ITEM DESCRIPTION Physical Characteristics Height 212 mm Dimensions Length 110 mm Width 74 mm Weight 395 g Electrical Characteristics Battery Type Li lon battery pack i a Charge time for 4 hours with external power supply adapter full charge from full discharge Typical 10 hours with Host power in this case no supply adapter is needed Operating autonomy con 30 000 reads typica
23. e battery is completely charged when the Reader LED on the cradle battery charger turns green The battery can also be charged in the spare battery slot BC91xx models only or using the Multi Battery Charger accessory Changing the Batteries 1 Push the button at the bottom of the handle as shown to release the battery 2 Pull down to remove the battery Button 1 Do not incinerate disassemble short termi nals or expose to high temperature at risk of fire explosion Use specified charger only Risk of explosion if the battery is replaced by incor rect type Dispose of batteries as required by WARNING the relevant laws in force 6 PowerScan PM9500 Programming Programming The reader is factory configured with a set of standard default features Customize your reader through use of the programming bar codes available in the PowerScan PM9500 Check the corresponding features section for your interface and also the Data Editing and Symbologies chapters of the PRG Using Programming Bar Codes This manual contains bar codes which allow you to recon figure your reader Some programming bar code labels like the Reset Default Settings on page 7 require only the scan of that single label to enact the change Other bar codes require the reader to be placed in Pro gramming Mode prior to scanning them Scan an ENTER EXIT bar code once to enter Programming Mode scan the desired parameter settings scan
24. ed on the sides of the Scanner as shown below Sample labels are shown here to illustrate their location only Please view the labels on your product for actual details as they may vary from those depicted Scanner Regulatory Labels LA LUCE LASER E VISI BILE ALL OCCHIO UMANO E VIENE DIE LASER LE RAYON STRAHLUNG IST LASER EST A LUZ LASER FUR DAS MEN VISIBLE A ES VISIBLE AL SCHLICHE AUGE L OEIL NU ET IL OJO HUMANO SICHTBAR UND EST MIS PAR Y ES EMITIDA EMESSA WIRD AM LA FENETRE POR LA VEN DALLA FINES STRAHLAUS DESIGNEE SUR TANA INDI TRA INDI TRITTSFENSTER LILLUSTRA CADA EN LA CATA NELLA AUSGESENDET TION DANS LA FIGURA FIGURA SIEHE BILD FIGURE 26 PowerScan PM9500 Regulatory Information LUCE LASER NON FISSARE RAYON LASER IL FASCIO LASERSTRAH EVITER DE APPAREC LUNG NICHT IN REGARDER LE CHIO LASER DEN STRAHL RAYON APPA DICLASSE2 BLICKEN PRO REIL LASER DE MASSIMA DUKT DER CLASSE 2 POTENZA LASERKLASSE 2 PUISSANCE DE D USCITA MAXIMALE AUS SORTIE LUNGHEZZA GANGSLEISTUNG LONGUEUR D ONDA WELLENLAGE D ONDE EMISE EMESSA ENTSPR EN CONFORME A CONFORME A 60825 1 2007 EN 60825 1 EN 60825 1 2007 2007 RAYO L SER NO MIRAR FIJO EL RAYO APARATO L SER DE CLASE 2 M X IMA POTEN CIA DE SALIDA LONGITUD DE ONDA EMIT IDA CONFORME A EN 60825 1 2007 ENGLISH The following information is provided to comply with the rules imposed by international authorities a
25. erformance Do not discharge the battery using any device except for the scanner When the bat tery is used in devices other than the desig nated product it may damage the battery or WARNING reduce its life expectancy If the device causes an abnormal current to flow it may cause the battery to become hot explode or ignite and cause Serious injury Lithium ion battery packs may get hot explode or ignite and cause Serious injury if exposed to abusive conditions Be sure to follow the safety warnings that follow e Do not place the battery pack in fire or heat Do not connect the positive terminal and negative terminal of the battery pack to each other with any metal object such as wire e Do not carry or store the battery pack together with metal objects Quick Reference Guide 3 Installing the Battery Pack WARNING CAUTION Do not pierce the battery pack with nails strike it with a hammer step on it or other wise subject it to strong impacts or shocks Do not solder directly onto the battery pack Do not expose the battery pack to liquids or allow the battery to get wet Do not apply voltages to the battery pack contacts In the event the battery pack leaks and the fluid gets into your eye do not rub the eye Rinse well with water and immediately seek medical care If left untreated the battery fluid could cause damage to the eye Always charge the battery at 32 113 F 0 45
26. ference Guide 19 LED and Beeper Indications Programming Mode The following indications ONLY occur when the reader is in Programming Mode INDICATION DESCRIPTION BEEPER Label Pro gramming Mode Entry Label Pro gramming Mode Rejec tion of Label Label Pro gramming Mode Accep tance of Par tial Label Label Pro gramming Mode Accep tance of Pro gramming Label Pro gramming Mode Cancel Item Entry 20 A valid program ming label has been scanned A label has been rejected In cases where multiple labels must be scanned to program one feature this indica tion acknowledges each portion as it is successfully scanned Configuration option s have been successfully pro grammed via labels and the reader has exited Program ming Mode Cancel label has been scanned Reader sounds four low fre quency beeps Reader sounds three times at lowest fre quency and cur rent volume Reader sounds one short beep at highest fre quency and cur rent volume Reader sounds one high fre quency beep and 4 low fre quency beeps followed by reset beeps Reader sounds two times at low frequency and current vol ume PowerScan PM9500 Error Codes Error Codes Upon startup if the reader sounds a long tone this means the reader has not passed its automatic Selftest and has entered FRU Field Replaceable Unit isolation mode If the reader is reset the sequence will
27. gic com Spanish Si desea informaci n acerca de los procedimientos para el desecho de los residuos del equipo el ctrico y electr nico WEEE visite la p gina Web www datalogic com Portuguese Para informa es sobre a disposi o de Sucatagem de Equipamentos El tricos e Eletr nicos WEEE Waste Electrical and Electronic Equipment consultar o site web www datalogic com Chinese KALE RABA Fis WEEE WAR 3825 Datalogic 4H Hh ok www datalogic com Japanese Be Ret thas WEEE OLE IZOW TO Pi 2313 Datalogic O34 F www datalogic com 223 HAR AVY Quick Reference Guide 31 Datalogic ADC Limited Factory Warranty Datalogic ADC Limited Factory Warranty Warranty Coverage Datalogic warrants to Customer that Datalogics products will be free from defects in materials and workmanship for a period of one year from product shipment Datalogic Datalogic hard ware products are warranted against defects in material and workmanship under normal and proper use The liability of Data logic under this warranty is limited to furnishing the labor and parts necessary to remedy any defect covered by this warranty and restore the product to its normal operating condition Repair or replacement of product during the warranty does not extend the original warranty term Products are sold on the basis of specifications applicable at the time of manufacture and Data logic has no obligation to modify or update products once sold
28. ho has pur chased or otherwise acquired a Datalogic Product End User For purposes of this Agreement any software that is associated with a separate end user license agreement is licensed to you under the terms of that license agreement Datalogic and End User hereby agree as follows 1 Definitions 1 1 Affiliate means a business entity currently existing or later acquired that con trols is controlled by or is under common control with Datalogic S p A 1 2 Documentation means materials such as user s guides program reference guides quick reference guides manuals or similar materials associated with or related to the Datalogic Product whether in printed online or other form 1 3 Proprietary Information means a source code object code software docu mentation and any related internal design system design data base design algorithms technology technical data or information implementation tech niques and trade secrets related to the Software b any other trade secrets marked appropriately or identified as proprietary or confidential and c any information that End User under the circumstances should recognize as con fidential Proprietary Information does not include any information that the receiving party can establish was 1 in the public domain 2 already in the receiving party s possession or rightfully known prior to receipt 3 rightfully learned from a third party not in violation of any other s
29. i n La utilizaci n de procedimientos o regula A ciones diferentes de aquellas describidas en la documentaci n puede causar una exposici n peligrosa a la luz l ser visible ATENCI N El aparato utiliza un diodo l ser a baja potencia No son notorios da os a los ojos humanos a consecuencia de una exposici n de corta duraci n Eviten de mirar fijo el rayo l ser as como evitar an cualquiera otra fuente de lumino sidad intensa por ejemplo el sol Adem s eviten de dirigir el rayo l ser hacia los ojos de un observador tambi n a trav s de superficies reflectantes como los espejos The PowerScan Handheld Reader is not user serviceable Opening the case of the unit can cause internal damage and will void the warranty CAUTION 30 PowerScan PM9500 Regulatory Information WEEE Statement Waste Electrical and Electronic Equipment WEEE Statement English For information about the disposal of Waste Electrical and Electronic Equipment WEEE please refer to the website at www datalogic com Italian Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www datalogic com French Pour toute information relative l limination des d chets lectroniques WEEE veuillez consulter le site internet www datalogic com German Informationen zur Entsorgung von Elektro und Elektronik Altgeraten WEEE erhalten Sie auf der Webseite www datalo
30. ing soft ware firmware changes in products shipped to the buyer Customers Under Software Support Customers that elect to subscribe to Datalogic Software Maintenance and Support Agreement will receive 30 days advance notification of 1 the release of a new software version and or 2 discontinuation of any prior software version that will no longer be supported Datalogic will provide maintenance for a fee that will assist customers in transitioning to the next software version If a customer is currently using the software version being discontinued the customer may elect to transition to any one of the newer versions depending on the hardware in use To arrange for a Software Maintenance and Support Agreement please con tact your Datalogic sales person vi PowerScan PM9500 Powerscan PM9500 Description The PowerScan PM9500 is a feature rich and rugged area imager reader It is offered in several different mod els to better fit the different needs of each customer The table below shows the unique features of each model Model P N Optical feature PM9500 XX Standard optic standard and low density codes PM9500 HPXX Autofocus optic High standard and low density codes wide angle High Density optic high and medium density E EES codes DPM laser ink jet and dot peen PM9500 DXX standard optic standard and low density codes Display and 4 keys keypad Autofocus optic high standard and low density pi eee lee
31. ir or unauthorized installation and shall be void if End User modifies the product uses the product in any manner other than as established in the Documentation or if End User breaches any of the provisions of this Agreement 6 2 EXCEPT AS PROVIDED IN THIS AGREEMENT THE DATALOGIC PRODUCT IS PROVIDED AS IS AND DATALOGIC MAKES NO WARRANTIES OF ANY KIND EXPRESS OR IMPLIED WRITTEN OR ORAL WITH RESPECT TO THE PRODUCT AND SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE 7 Infringement 7 1 Datalogic will defend End User against any claim in a lawsuit that the Data logic Product furnished hereunder infringe a United States patent or copyright of a third party and Datalogic will pay any damages finally awarded against End User by a court of competent jurisdiction that are attributable to such claim or will pay End User s part of any settlement that is attributable to such claim provided that 1 End User notifies Datalogic promptly in writing of the iV PowerScan PM9500 claim 2 Datalogic controls the defense or settlement of the claim and 3 End User cooperates fully with Datalogic in such defense or settlement All notices of a claim should be sent to Datalogic ADC Inc Legal Department 959 Terry Street Eugene OR 97402 7 2 In the defense or settlement of any such claim Datalogic may at its option 1 procure for End User the right to continue using the Datalogic Product
32. l tinuous reading Cradle consump Volt 10 30 VDC Power SUN tion and DCinput Max 500mA when in host bus powered supply range mode a Charge Times are much lower when battery is within daily typical operating condition b Typical input current measured under factory default configuration Quick Reference Guide 13 Technical Specifications Roll Tilt Tolerance Pitch Tolerance e ance Print Contrast Minimum 15 minimum reflectance DESCRIPTION Max resolution 1D 4 mils 1D 2 5 mil Max resolution 2D 2D 4 mil 7 5 mils Depth of Field Typical Symbology Standard Model High Performance 4 mils 6 17 cm 2 5 mils 2 6 cm Code 39 20 mils 4 55 cm 20 mils 3 70 cm 40 mils 4 85 cm 40 mils 3 110 cm EAN 13 13 mils 4 48 cm 13 mils 3 60 cm PDF 417 10 mils 2 25 cm 10 mils 2 30 cm 7 5 mils 7 14 cm 4 mil 2 6 cm 10 mils 4 18 cm 10 mil 2 20 cm Resolution DataMatrix a 13mils DOF based on EAN All other 1D codes are Code 39 All labels grade A 300 lux ambient light 20 C label inclination 10 14 PowerScan PM9500 Technical Specifications DECODE CAPABILITY 1D Bar Codes GS1 Databar linear codes UPC EAN A E 13 8 UPC EAN with P2 P5 Addons UPC EAN Coupons ISBN Code128 EAN128 ISBT128 Code39 Code39 Full ASCII Code39 CIP Code 32 Codabar Inter leaved 2 of 5 IATA Industrial 2 of 5 Standard 2 of 5 Code11 MSI Plessey Code 93 Follet 2 5 2D Stacked Codes DataMatri
33. mp CAUTION Safety Manager to ensure that you are adher ing to your company s safety programs to pre vent employee injury Reduce or eliminate repetitive motion Maintain a natural position Reduce or eliminate excessive force Keep objects that are used frequently within easy reach Perform tasks at correct heights Reduce or eliminate vibration Reduce or eliminate direct pressure Provide adjustable workstations Provide adequate clearance Provide a suitable working environment Improve work procedures 34 PowerScan PM9500 Services and Support Services and Support Datalogic provides several services as well as technical support through its website Log on to www datalogic com and click on the links indicated for further informa tion Products Search through the links to arrive at your product page where you can download specific Manuals and Software amp Utilities including Datalogic Aladdin a multi platform utility pro gram that allows device configuration using a PC It provides RS 232 and USB COM interface configu ration printing of configuration bar codes and firmware upgrades Service amp Support Technical Support Product documentation and programming guides and Technical Support Department in the world Service Programs Warranty Extensions and Maintenance Agreements Repair Services Flat Rate Repairs and Return Material Authorization RMA Repairs
34. nd refers to the correct use of your terminal STANDARD LASER SAFETY REGULATIONS This product conforms to the applicable requirements of both CDRH 21 CFR 1040 and EN 60825 1 at the date of manufacture For installation use and maintenance it is not necessary to open the device Use of controls or adjustments or perfor A mance of procedures other than those specified herein may result in exposure to WARNING hazardous visible laser light The product utilizes a low power laser diode Although staring directly at the laser beam momentarily causes no known biological damage avoid staring at the beam as one would with any very strong light source such as the sun Avoid that the laser beam hits the eye of an observer even through reflective surfaces such as mirrors etc Quick Reference Guide 27 Regulatory Information ITALIANO Le seguenti informazioni vengono fornite dietro direttive delle autorita internazionali e si riferiscono all uso corretto del terminale NORMATIVE STANDARD PER LA SICUREZZA LASER Questo prodotto risulta conforme alle normative vigenti sulla sicurezza laser alla data di produzione CDRH 21 CFR 1040 e EN 60825 1 Non si rende mai necessario aprire l appa recchio per motivi di installazione utilizzo o manutenzione L utilizzo di procedure o regolazioni AN differenti da quelle descritte nella documentazione pu provocare ATTENZIONE un esposizione pericolosa a luce laser visibile Il prodotto u
35. o maintain a back up copy of its software and data Warranty Claims Process In order to obtain service under the Factory Warranty Customer must notify Datalogic of the claimed defect before the expiration of the applicable Warranty period and obtain from Datalogic a re turn authorization number RMA for return of the product to a designated Datalogic service center If Datalogic determines Cus tomer s claim is valid Datalogic will repair or replace product without additional charge for parts and labor Customer shall be responsible for packaging and shipping the product to the desig nated Datalogic service center with shipping charges prepaid Datalogic shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Da 32 PowerScan PM9500 Datalogic ADC Limited Factory Warranty talogic service center is located Customer shall be responsible for paying all shipping charges duties taxes and any other charges for products returned to any other locations Failure to follow the applicable RMA policy may result in a processing fee Customer shall be responsible for return shipment expenses for products which Datalogic at its sole discretion determines are not defective or eligible for warranty repair Warranty Exclusions The Datalogic Factory Warranty shall not apply to i any product which has been damaged modified altered repaired or upgraded by other than Datalogi
36. of this provision shall be valid or binding upon Datalogic DATALOGICS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED ORAL OR WRITTEN STATU TORY OR OTHERWISE INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT DATALOGIC SHALL NOT BE LIABLE FOR ANY DAMAGES SUSTAINED BY CUS TOMER ARISING FROM DELAYS IN THE REPLACEMENT OR RE PAIR OF PRODUCTS UNDER THE ABOVE THE REMEDY SET FORTH IN THIS WARRANTY STATEMENT IS THE CUSTOMER S SOLE AND EXCLUSIVE REMEDY FOR WARRANTY CLAIMS UNDER NO CIRCUMSTANCES WILL DATALOGIC BE LIABLE TO CUSTOMER OR ANY THIRD PARTY FOR ANY LOST PROFITS OR ANY INCIDEN Quick Reference Guide 33 Ergonomic Recommendations TAL CONSEQUENTIAL IN DIRECT SPECIAL OR CONTINGENT DAMAGES REGARDLESS OF WHETHER DATALOGIC HAD AD VANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES Risk of Loss Customer shall bear risk of loss or damage for product in transit to Datalogic Datalogic shall assume risk of loss or damage for product in Datalogic s possession In the absence of specific writ ten instructions for the return of product to Customer Datalogic will select the carrier but Datalogic shall not thereby assume any liability in connection with the return shipment Ergonomic Recommendations In order to avoid or minimize the potential risk of ergonomic injury follow the recommenda tions below Consult with your local Health a
37. otherwise reproduce or remanufacture the Software whether modified or unmodified nor sell assign sublicense distribute lend rent give or otherwise transfer the Software to any other person or organization for purposes other than as expressly provided in this Agreement without Datalogic s prior written consent 3 Transfers Support 3 1 Any copying installing reproduction remanufacture reverse engineering electronic transfer or other use of the Software on other than the designated Datalogic Product will be a material breach of this Agreement However Data logic may elect not to terminate this Agreement or the granted licenses but instead may elect to notify End User that End User is deemed to have ordered Quick Reference Guide iii and accepted a license for each breaching use End User shall pay Datalogic the applicable list price for such licenses as of the date of such breach 3 2 End User shall not sell assign sublicense distribute lend rent give or other wise transfer the Datalogic Product to any third party unless such third party agrees with Datalogic in writing to be bound by the terms and conditions of this Agreement Any such transfer of the Datalogic Product absent such agreement shall be null and void 3 3 End User may obtain support for Software from Datalogic at Datalogic s stan dard support fees and under Datalogic s standard support terms and condi tions in effect at the time the support is requeste
38. ration is noticeable after one year of service whether the battery is in use or not It is difficult to precisely predict the finite life of a Ll battery but cell manufacturers rate them at 500 charge cycles In other words the batteries should be expected to take 500 full discharge charge cycles before needing replacement This number is higher if partial dis charging recharging is adhered to rather than full deep discharging The typical manufacturer advertised useful life of LI bat teries is one to three years depending on usage and num ber of charges etc after which they should be removed from service especially in mission critical applications Do not continue to use a battery that is showing excessive loss of capacity it should be properly recycled disposed of and replaced For most applications batteries should be replaced after one year of service to maintain customer satisfaction and minimize safety concerns Collect and recycle waste batteries separately from the device in comply with European Directive 2006 66 EC 2011 65 EU 2002 96 EC 2012 19 EU and subsequent modifications US and China regulatory and others laws and regulations about the environment Quick Reference Guide 5 Installing the Battery Pack Charging the Batteries Once the BC 90x0 is powered you can charge the reader s batteries Place the PowerScan M9500 into the BC 90x0 cradle The Reader LED on the cradle battery charger turns red Th
39. rence Guide QRG available on the Datalogic website Using the PowerScan PM9500 The PowerScan PM9500 normally functions by capturing and decoding bar codes The reader is equipped with an internal motion sensing function which activates the aiming system on device motion The intelligent aiming system indicates the field of view which should be posi tioned over the bar code Table 1 Aiming System MODEL P N AIMER PATTERN PM9500 PM9500 DPM PM9500 HP PowerScan PM9500 Installing the Battery Pack The field of view indicated by the aiming system will be smaller when the reader is closer to the bar code and larger when it is farther from the code Symbologies with smaller bars or elements mil size should be read closer to the unit Symbologies with larger bars or elements mil size should be read farther from the unit If the entire bar code is within the aiming field you will get a good read Successful reading is signaled by an audible tone plus a good read green spot LED indicator Reference the PowerScan 9500 Product Reference Guide PRG for more information about this feature and other programmable settings Installing the Battery Pack To install charge and or do any other action on the bat tery follow the instructions in this manual To charge the Battery Pack See Charging the Batteries on page 6 Datalogic recommends annual replacement of rechargeable battery packs to ensure maximum p
40. rettive del Consiglio Europeo sottoelencate are in conformity with the requirements of the European Council Directives listed below sont conformes aux sp cifications des Directives de l Union Europ enne ci dessous den nachstehenden angef hrten Direktiven des Europaischen Rats cumple con los requisitos de las Directivas del Consejo Europeo seg n la lista siguiente 1999 5 EC R amp TTE Directive 2011 65 EU RoHS Directive Questa dichiarazione basata sulla conformit dei prodotti alle norme seguenti This declaration is based upon compliance of the products to the following standards Cette d claration repose sur la conformit des produits aux normes suivantes Diese Erkl rung basiert darauf dab das Produkt den folgenden Normen entspricht Esta declaraci n se basa en el cumplimiento de los productos con las siguientes normas ETSI EN 301 489 17 v2 1 1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MAT May 2009 TERS ERM ELECTROMAGNETIC COMPATIBILITY EMC STAN DARD FOR RADIO EQUIPMENT AND SERVICES PART 3 SPECIFIC CONDITIONS FOR SHORT RANGE DEVICES SRD OPERATING ON FREQUENCIES BETWEEN 9KHZ AND 40GHZ EN 301 489 1 V1 8 1 APRIL ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM 2008 MATTERS ERM ELECTROMAGNETIC COMPATIBILITY Emc STANDARD FOR RADIO EQUIPMENT AND SERVICES PART 1 COMMON TECHNICAL REQUIREMENTS ETSI EN 300 220 2 V2 1 2 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MAT JUNE 2007 TERS
41. rovide informa tion in this manual that is complete and accurate however Datalogic reserves the right to change any specification at any time without prior notice Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U All other brand and product names may be trade marks of their respective owners Patents This product may be covered by one or more of the following pat ents Design Patents AU344427 AU344428 AU344429 EP1970237 USD682277 ZL 201230284676 X Utility Patents EP996284 EP999514 EP1128315 EP1172756 EP1396811 EP1413971 EP1828957 JP4435343 US5481098 US6478224 US6512218 US6513714 US6561427 US68081 14 US6877664 US6997385 US7053954 US7234641 US7387246 US7721966 Additional patents pending E E Table of Contents Software Product POllCV risas ari vi Customers Under Software Support nsssssserereererenss vi CER 1 General Features os 1 Using the PowerScan 29500 sse 2 installing the Battery Pack renos 3 Charging the Batteries criari iii 6 Changing the Batteries 4 vbi ionic eseki es 6 E ETE IAA A 7 Using Programming Bar Codes eene 7 Configure Other SeEEIDIBS Losses tibia rk Reb nx ad 7 Resetting Product Defaults 7 Compatibility with the PowerScan 8000 family 8 Set Date a a IE rara 8 E 9 Link Datalogic RF Devices to Base 9
42. rs Minutes and Seconds HHMMSS from the Hex Numeric Key pad on page 36 y pim mile Set Time 4 Scan the Enter Exit Programming bar code to complete 8 PowerScan PM9500 Linking the Reader Linking the Reader Link Datalogic RF Devices to Base For RF devices before configuring the interface it is nec essary to link the handheld with the base To link the handheld and the base press the trigger to wake up the handheld and mount it on the base If the reader was previously linked to another base you must first scan the Unlink bar code before re linking to the new base alla Unlink Power Off Scan the bar code below to shut off power to the BT hand held until the next trigger pull PowerOff Quick Reference Guide 9 Operating Mode Operating Mode Scan Mode The imager can be set to operate in one of several scan ning modes See the PRG for more information and set tings for any of the options Trigger Single Default When the trigger is pulled scan ning is activated until one of the following occurs a programmable duration has elapsed alabel has been read the trigger is released Trigger Hold Multiple When the trigger is pulled scan ning starts and the product scans until the trigger is released or maximum scan on time has elapsed Read ing a label does not disable scanning Double Read Time out prevents undesired multiple reads in this mode Trigger Pulse
43. teps to protect the Propri etary Information no less securely than if it were End User s own intellectual property 5 3 The provisions of this Proprietary Information Section shall survive and con tinue for five 5 years after the termination of this Agreement 6 Limited Warranty 6 1 Datalogic warrants that under normal use and operation the Datalogic Prod uct will conform substantially to the applicable Documentation for the period specified in the Documentation During this period for all reproducible non conformities for which Datalogic has been given written notice Datalogic will use commercially reasonable efforts to remedy nonconformities verified by Datalogic End User agrees to supply Datalogic with all reasonably requested information and assistance necessary to help Datalogic in remedying such nonconformities For all defects reported to Datalogic within the warranty period Datalogic s liability is limited to providing End User with one copy of corrections or responding to End User s problem reports according to Data logics standard assistance practices Datalogic does not warrant that the product will meet End User s requirements or that use of the product will be uninterrupted or error free or that Datalogics remedial efforts will correct any nonconformance This limited warranty does not cover any product that have been subjected to damage or abuse whether intentionally accidentally or by neglect or to unauthorized repa
44. tilizza un diodo laser a bassa potenza Seb bene non siano noti danni riportati dall occhio umano in seguito ad una esposizione di breve durata evitare di fis sare il raggio laser cosi come si eviterebbe qualsiasi altra sorgente di luminosit intensa ad esempio il sole Evitare inoltre di dirigere il raggio laser negli occhi di un osserva tore anche attraverso superfici riflettenti come gli spec chi DEUTSCH Die folgenden Informationen stimmen mit den Sicherheit shinweisen berein die von internationalen Beh rden auferlegt wurden und sie beziehen sich auf den korrekten Gebrauch vom Terminal NORM F R DIE LASERSICHERHEIT Dies Produkt entspricht am Tag der Herstellung den gulti gen EN 60825 1 und CDRH 21 CFR 1040 Normen f r die Lasersicherheit 28 PowerScan PM9500 Regulatory Information Es ist nicht notwendig das Gerat wegen Betrieb oder Installations und Wartungs Arbeiten zu offnen Jegliche nderungen am Ger t sowie N Vorgehensweisen die nicht in dieser Betriebsanleitung beschreiben werden ACHTUNG konnen ein gefahrliches Laserlicht verur sachen Der Produkt benutzt eine Laserdiode Obwohl zur Zeit keine Augenschaden von kurzen Einstrahlungen bekannt sind sollten Sie es vermeiden f r langere Zeit in den Laserstrahl zu schauen genauso wenig wie in starke Lichtquellen z B die Sonne Vermeiden Sie es den Laser strahl weder gegen die Augen eines Beobachters noch gegen reflektierende Oberflachen
45. x MaxiCode and QR Codes QR Micro QR and Multiple QR codes Aztec Postal codes including Australian Post China Post Japanese Post KIX Post Planet Code Postnet Royal Mail Code RM45CC IMB stacked codes including EAN JAN Composites GS1 Databar Composites GS1 Databar Expanded Stacked GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional MacroPDF Micro PDF417 PDF417 UPC A E Composites French CIP13 Grid Matrix Chinese code Interfaces Supported RS 232 Keyboard Wedge and USB USER ENVIRONMENT Operating Tempera 4 to 122 F 20 50 C ture Storage Temperature 40 to 158 F 40 to 70 C Humidity 0 to 95 non condensing Scanner withstands gt 50 times 6 5 2 m drops to concrete Ambient Light 100 000 Lux Immunity Drop Specifications Quick Reference Guide 15 Technical Specifications Contaminants Spray rain IP65 Dust particulates ESD Level 20 KV Beeper Speaker gt 80dB 10cm Regulatory UL 60950 CSA C22 2 Electrical Safety No 60950 IEC 60950 433 MHz model Europe CE Russia Gost Australia EMI RFI Ctick China SRRC Singapore IDA Anatel Brazil 910 MHz model USA Canada FCC IC Mexico NOM Cofetel IEC Class 2 Laser Class Radiation 1 mW Avg Emitted wavelength Safety 650 nm 12ms pulse Beam Divergence 8 4 deg x 8 1 deg plus pattern Complies with FDA performance standards for laser products except for deviations pursu