Home

COOL MIST HUMIDIFIER

image

Contents

1. a Your Source for Home Comfort Perfect IP e PERSONAL TRAVEL COOL MIST HUMIDIFIER USER MANUAL FOR MODEL PAU Before using your ultrasonic A humidifier please read this manual carefully and keep s it for future reference along with your receipt T gt CONTENTS Safety Guidelines cocooocccocococococonoconnnncnnnononanonos 2 3 Fever 3 Technical Data esse seen 4 Structure Diagramm nennen 4 Operating Instructions e Setting up your humidifier ooccooccccccnococnncnos 5 e How to use your humidifier ooccccoooo 5 6 Weekly Maintenance Cleaning amp Care 6 Storage Instructions a 7 VG F FOUNESNOO Ne senn 8 SAFETY GUIDELINES When using electrical appliances basic safety precautions should always be followed Failure to follow these safety precautions may result in personal injury property damage fire or shock 1 Always have water in water tank water bottle when operating unit 2 Use only clean distilled or FILTERED tap water Using tap water with a high mineral content hard water will result in a white dust and the need for more frequent cleanings Hard water can be harmful to unit and may eventually cease its operation Be sure the water bottle adaptor is tightly and completely inserted into the water bottle Position the unit within the room so the air output from the mist control output nozzle is aimed away from ch
2. Voltage 120V 60HZ This product is designed for home Noise 3508 fee ony STRUCTURE DIAGRAM Water bottle adaptor Mist output direction control Cover Body Indicator light Power output adjustment knob Power cord with plug NOOR WD Ultrasonic Transducer Nebulizer white disk inside recessed ring at bottom of base OPERATING INSTRUCTIONS SETTING UP YOUR HUMIDIFIER Remove the water bottle adaptor from the unit 2 Open the water bottle Water bottle not included 3 Gently push the water bottle adaptor completely into the water bottle The adatpor should fit into the mouth of the water bottle snugly 4 Carefully put the water bottle to the bottom base Base will partially fill with water from bottle 5 Check the voltage then insert the plug fully 6 Turn on the humidifier OPERATING INSTRUCTIONS HOW TO USE YOUR HUMIDIFIER How to Use Your Humdifier 1 It is recommended that the humidifier base be cleaned before first use See cleaning instructions on next page 2 Be sure unit is at least 24 inches off of the floor Place unit on a firm level surface Do not place unit on overly soft unstable surface towel or wood The humidifier should be placed at least four 4 inches away from all walls and away from heat sources Continued on next page How to Use Your Humdifier continued 3 When refilling water bottle tank note a Always unplug unit before filling and repla
3. REQUIRED in order to obtain warranty assistance This warranty does NOT cover e Damages caused by improper installation or improper cleaning e Negligent use or misuse of the product e Damages as the result of not using product in accordance with provided instructions e Damage to product walls paintings portraits furniture floor etc as the result of high mineral content in water e Damage to product walls paintings portraits any furniture wood floors etc as a result of improper installation and or cleaning e Use of improper voltage or current e Additional or extended warranties offered by retailers e Disassembly or repair by anyone other than an authorized Perfect Aire service center provider e Products used in a commercial setting e Floor display as is models e Damage caused by acts of nature such as hurricane tornado fire etc Incidental or consequential damages caused by breach of any expressed implied or statutory warranty or condition with exception to the extent prohibited by law e Any performance issues that fall outside of the 1 year warranty Note Some states do not allow the exclusion or limitation of incidental or consequential damages This limitation or exclusion may not apply to you DO NOT RETURN THIS PRODUCT TO THE STORE If you have any questions about this product or its warranty please call consumer services at toll free 877 365 6274 TROUBLESHOOTING Please check the foll
4. all or Turn down the mist volume or turn the unit off windows or unit too humid completely Scaling on nebulizer Water is too hard Use distilled or filtered water transducer Mist circling in Too muekavaterinibase Empty base Trim ring from neck of water base but not bottle if necessary Leave space for air in bottle coming out of Water bottle brand not the nozzle compatible with unit Unit too far from end of Move unit closer to edge of table so mist has Damp table or table or too close to floor more time to disperse The water is dirty or stale Try a different brand of water bottle NOTE A highly recommended troubleshoot for any issue in general consists of removing the water bottle emptying the base and trying a different brand of water bottle as the unit is compatible with most but not all 20 oz plastic water bottles 8 are Your Source for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 8 7 365 6274 www perfectaire us Specification and performance data is subject to change without notice Printed in China
5. ated and leave condensation on walls or furniture Always leave room door partially open 14 DANGER NEVER immerse the humidifier motor unit base in water or other liquids as electrical shock may occur 15 DO NOT use outdoors 16 Turn humidifier OFF if the relative humidity exceeds 60 or if you notice condensation on inside of windows For proper humidity reading use a hydrometer which is available in many retail stores 17 The nebulizer ultrasonic transducer is highly sensitive Keep this important part clean and treat it gently Only clean per instructions WARNING e Do not touch the nebulizer while the unit is operating as possible burns could result Do not touch the nebulizer with fingers Any residue on the metal will reduce mist output 18 The unit contains no consumer serviceable parts To reduce the risk of electrical shock do not attempt to open the base of the humidifier SAFETY GUIDELINES continued DANGER To reduce the risk of electrical shock this product has a polarized plug one blade is wider than the other As a safety feature this plug will fit into the outlet only one way If the plug does not fit fully into the outlet reverse the plug If it still does not fit contact a qualified electrician DO NOT attempt to bypass this safety feature Improper use of electric cords and plugs can cause a fire or electric shock hazard NEVER pull on the cord to remove the plug from the outlet Grip plug and pull f
6. cing water bottle b Distilled or softened water is highly advised Minerals in hard tap water may cause a white dust to appear on furniture and can also eventually cause unit failure c Extreme temperatures can damage unit Water temperatures should NEVER be too hot or too cold Water temperature should fall between 40 F and 90 F d Return water bottle securely to base before turning on humidifier 4 To Turn Unit On a Plug power cord into a 110 120V AC wall outlet only b Turn the On Off Adjustment Knob in a clockwise direction to begin operation of unit c Turn mist output control nozzle to manually adjust mist direction 5 To Turn Unit Off a Turn unit off when desired room humidity is achieved by turning the On Off Adjustment Knob counter clockwise b Always turn unit off when water bottle is empty c Unit will automatically stop creating mist when water level in base is very low d Do not let water sit in water bottle tank or base for more than 24 hours e Unplug when not in use DANGER Improper use of electric cords and plugs can cause a fire or electric shock hazard NEVER pull on the cord to remove the plug from the outlet Grip plug and pull from outlet Check the power cord and plug for damage A damaged cord or plug must be repaired before using the humidifier WEEKLY MAINTENANCE CLEANING amp CARE IMPORTANT e Unplug the power cord before cleaning e NEVER use any cleaning products solutions which are abra
7. ildren walls and furniture When removing the water bottle have both hands securely on the bottle DO NOT use if tank water bottle is cracked DO NOT place the appliance near heating devices such as a stove Keep it out of direct sunlight Keep the cord away from heated surfaces and areas where it can be stepped on or tripped over 8 Use only 110 120V AC outlet Be sure unit is plugged in firmly and completely As with any electrical device plug and unplug unit with dry hands only 9 Turn the humidifier off and unplug the unit when not in use when moving or when cleaning 10 To avoid the risk of fire shock or personal injury do not use an extension cord Warning Never operate unit with a damaged cord or plug 11 Never set on floor Always place unit on a flat level waterproof surface at least 24 inches off floor AWAY from direct sunlight computers or other sensitive electronic equipment DO NOT place the humidifier on wood furniture or other surfaces that can be damaged by water DO NOT place on floor or carpet 12 DO NOT add medication or cleaning products of any type into the mist control nozzle base or water tank See Weekly Maintenance Cleaning amp Care section of this manual for proper instructions on cleaning the unit DO NOT cover block or place anything over any opening NEVER drop or insert any object into any openings 13 The unit should not be left unattended in closed rooms as air could become satur
8. owing troubleshooting tips before calling for assistance Problem Reason Yan O O E Plug in unit and turn on the Power output Unit not plugged in i Power light is off adjustment knob Wall outlet has no power Check the circuit and fuse try another socket Air unit out in cool place for 12 hours without New unit Unit Mist has the water bottle on the unit eculiar smell j j p The water is dirty or stale Thoroughly clean unit and place fresh water in bottle tank Excessive noise OO BEN en IE Place the unit on a stable waterproof surface humidifier and surface Water contains high Switch to distilled or filtered water clean White dust mineral content nebulizer according to instructions floor Water bottle adaptor not securely attached or Base overflowed needs replacement Base overfilled Empty base and restart EEE ome No water in water bottle Add water to the water bottle The power output knob Rotate the power output adjustment knob is not turned on clockwise to power the unit on Foe Ne norana Put the humidifier on a flat surface flat surface There is scaling on the Clean the nebulizer transducer according to nebulizer transducer instructions Add water to the water tank or replace it will The water level is too low another filled water bottle Thoroughly clean unit and place fresh water in bottle tank The nebulizer transducer Call Perfect Aire Consumer Services Condensation on The room is too sm
9. rom outlet Check the power cord and plug for damage A damaged cord or plug must be repaired before using the humidifier FEATURES PowerRefl Micro Mist Whisper Quiet Adjustable Auto Shut Off Active Carbon Waterless Operation Output Levels Filter Indicator Ultrasonic Technology Ultrasonic technology is widely used in various domains Water is atomized by ultrasonic sound waves and propelled through the air by a small fan These ultrasonic pulses are silent and produce visible mist that quickly disperses to increase the level of humidity in the immediate area The unit features an easy to clean ultrasonic transducer nebulizer for increased longevity Auto Shut Off Protection Waterless Indicator When the water tank is empty the motor will shut off automatically and Power Indicator Light will turn red Micro Mist Micro mist water particles are smaller than water particles produced by regular ultrasonic humidifiers Benefits of micro mist technology include up to 40 greater output water vapor particles 70 80 smaller for quicker air dispersion 25 greater room coverage and less condensation on and around unit Overload Protection The unit will automatically shut off if a circuit is overloaded TECHNICAL DATA Model No PAU Water Tank 12 24 oz Output per Hour 3 5 5 0 oz hr E 2 FOR HOUSEHOLD USE ONLY Output per Day 0 6 0 95 gal day All data was tested by the factory and is for reference only 12W
10. sive corrosive or flammable as these can be harmful to the unit and void warranty if used Cleaning Instructions 1 Clean base every week for optimum performance a Fill the base 4 oz of undiluted white vinegar b Let the solution stand for 20 minutes c With the vinegar in the base clean all the interior surfaces with a soft cloth or brush to help remove scales Do not touch the nebulizer with fingers Any residue on the nebulizer will reduce mist output d Carefully rinse with clean warm water and gently wipe clean 2 Regularly clean the outer surface with a damp soft cloth to prevent dust accumulation 3 Discard and replace water bottle when signs of wear are evident STORAGE INSTRUCTIONS 1 Clean unit thoroughly according to instructions and allow to dry completely before storing 2 Store unit in an upright position away from sunlight Do not store in temperatures below 41 F ONE YEAR LIMITED WARRANTY PERFECT AIRE warrants that during the first year from the original date of purchase this product will be free from defects in material and workmanship Perfect Aire at its discretion will repair or replace this product or any component of this product found to be defective during the warranty period This is a one time replacement warranty If the product is no longer available Perfect Aire will replace the unit with a similar model of equal or greater value This warranty is not transferable Proof of purchase is

Download Pdf Manuals

image

Related Search

Related Contents

Copyright © All rights reserved.
Failed to retrieve file