Home

User Manual

image

Contents

1. SOUND AND LIGHT INDICATION Operation Status LED Buzzer Stand by Red light bright Enter into programming mode Red light blinks One beep In the programming mode Orange light bright One beep Operation error Three beeps Open lock Green light bright One beep Alarm Red light Shines quickly Beeps 3 Connection Diagram DC POWER SUPPLY Magnetic Lock or Fail Safe In4004 DC Power Supply DC Alarm Magnetic Lock or Fail Safe Lock prp pet ee In4004 pen LOT gt I Grey Door Contact i FT DC Power IMPORTANT When use AC power supply it must be connected with the Red wire AC1 and the Pink wire AC2 of the reader It is forbidden to connect the AC power to Black wire GND or the reader will be damaged Install a 1N4004 or equivalent diode is needed when use a common power supply or the reader might be damaged 1N4004 is included in the packing KB Programming RN PROGRAMMING BY INFRARED REMOTE CONTROL Programming will vary depending on access confirguration Follow the instructions according to your access configuration User ID number Assign a user ID to the access card in order to track it The common user ID number can be any number fom 0 997 the panic user ID is from 998 999 IMPORTANT User IDs do not have to be proceeded with any leading zeros Recording of User ID is critical Modifications to the user require the User
2. ID be available Proximity Card Any 125KHz industry standard 26 bit EM and HID Proximity card or Tag ADD COMMON USERS Programming Step Keystroke Combination Enter Programming Mode FEIET TET Master Code ADD CARD USER Add Card Using Auto ID Allows READ CARD S1 2 3 4 X to assign Card to next Cards can be added continuously available User IDnumber OR Add Card Select Specific ID L IL IL User ID Allows Master to define a specific User ID to associate the READ CARD card to User ID is any number from 0 997 OR Add Card Block Enrolment L IE gt Allows Master to add up to 998 User ID cards to the Reader in a single ARD ANTI Z step Takes 2 minutes to program c QU TY FIRST CARD NUMBER Cards number must be consecutive Card quantity number of cards to be enrolled Exit ADD PANIC USERS Programming Step Keystroke Combination Enter Programming Mode ESTE JE COE TE E EI Master Code Add Card OOL User ID Read Card I t 8 10 Sight reder Exit DELETE USERS Programming Step Enter Programming Mode Keystroke Combination ESTE JE JE OE TE BE Master Code Delete Card User Common Delete Card by Card OR Delete Card By ID Number OR Delete User By Card Number 2 READ CARD Cards can be deleted continuously i2 OLI User ID Input 8 10 digit card number Delete Panic User Del
3. DOLCSAW1000H Reader z EB zz oO 1 gt aa Aa Q Dm fa aQ Quick Start Guide Installation and Wiring ST Connection Diagram Dolphin Programming Guide Md The DOLCSAW l 000H is a single door multifunction standalone access controller FEE REO Waterproof conforms to IP66 Onerelay remote infrared programmer 1 000 users 998 common users 2 panic users Can be set to read EM card HID card or both Card block enrolment Tri colour LED status display Integrated alarm amp buzzer output Pulse mode Toggle mode Can add and use 4 6 digits PIN on Infrared Remote Control 2 devices can be interlocked for 2 doors Built in light dependent resistor LDR for anti tamper e Low temperature resistance 409F SPECIFICATIONS User Capacity 1000 Common User 998 Operating Voltage 12 24VAC DC Idle Current 35mA Proximity Card Reader EM amp HID Radio Technology 125KHz Proximity Card Read Range 2 6 cm Wiring Connections Relay Output Exit Button Relay One NO NC Common Adjustable Relay Output Time 1 99 Seconds 5 seconds default Lock Output Load 2 Amp Maximum Environment Meets IP66 Operating Temperature 40 C 60 C 40 F 140 F Operating Humidity 0 98 RH Physical ABS Shell Color Black White optional Dimensions L120mm xW48mm xD20mm Unit Weight 150g Shipping Weight 220g 1 Quick Start Guide Function Description Operation Enter Programming Mode OGGE Master Co
4. ODS EXPRESS OR IMPLIED INCLUDING WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICU LAR PURPOSE BUYER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS EXPRESS OR IMPLIED WITH REGARD TO THE GOODS AND ACCEPTS THEM AS IS WHERE IS TRANSMITTER SOLUTIONS SELLS THE GOODS TO BUYER ON CONDITION THAT TRANSMITTER SOLUTIONS WILL HAVE NO LIABILITY OF ANY KIND AS A RESULT OF THE SALE BUYER AGREES THAT TRANSMITTER SOLUTIONS SHALL HAVE NO LIABILITY FOR DAMAGES OF ANY KIND WHETHER DIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING INJURIES TO PERSONS OR PROPERTY TO BUYER ITS EMPLOYEES OR AGENTS AS A RESULT OF THE SALE BUYER ALSO AGREES TO HOLD TRANSMITTER SOLUTIONS HARMLESS FROM ANY CLAIMS BUYER OR ANY THIRD PARTY MAY HAVE AS A RESULT OF BUYER S USE OR DISPOSAL OF THE GOODS BUYER HAS READ THIS DISCLAIMER AND AGREES WITH ITS TERMS IN CONSIDERATION OF RECEIVING THE GOODS AY Transmitter SOLUTIONS Pierce Building 3788 West 2270 South Suite E Salt Lake City UT 84120 866 975 0101 866 975 0404 fax www transmittersolutions com
5. de Default Master Code is 123456 Change the Master Code 0 OG gt New Master Code NORD Repeat New Master Code Add Card User READ CARD Cards can be added continuously Delete User 2 READ CARD For card user Exit from Programming Mode IN THE BOX Diode IN4004 For relay circuit protection DOLCSAW1000H EE am me Wall Anchors Self Tapping Screws e Screw Driver C J Master Add Card Master Delete Card Infrared Remote Control Master Cards Installation and Wiring Remove the back cover from the unit Drill 2 holes A C on the wall for the screws and one hole for the cable Knock the supplied rubber bungs to the screw holes A C Fixthe back cover firmly on the wall with 4 flat head screws Thread the cable through the cable hole B Attach the unit to the back cover Wire Color Function Notes Red AC 1 4 DC 12 24V AC Power Input 12 24V DC Power Input Black GND Negative Pole of DC Power Input Pink AC2 12 24V AC Power Input Blue Relay NO Normally Open Relay Output install diode provided Purple Relay Common Common Connection for Relay Output Orange Relay NC Normally Closed Relay Output Install diode provided Yellow OPEN Output Install diode provided Advanced Input and Output Features Grey Alarm Output Negative contact for Alarm Brown Contact Input Door Gate Contact Input Normally Closed
6. ete Panic Card User OR Delete Panic PIN User 2 EL IL TE EF User ID 2 OOL Exit User ID SET RELAY CONFIGURATION Programming Step Keystroke Combination Enter Programming Mode ESL TE JE OE TE E BE Master Code Pulse Mode CIL OR p Relay Time 1 99 seconds Default is 5 seconds Toggle Mode o Sets the relay to ON OFF toggle mode Exit SET STRIKE OUT ALARM The strike our alarm will engage after 10 failed card attempts Factory is OFF It can be set to deny access for 10 minutes after engaging or disengage only after entering a valid card PIN or Master code Programming Step Keystroke Combination Enter Programming Mode SIE TE TE JE JE E B Master Code Strike Out OFF OR Strike Out ON OR Strike Out ON alarm Set alarm time 6 o factory default 6 1 E iaae n 6 2 4 5 L 1L i Alarm Time 0 30 Default is 1 minute Enter Master code ft or valid user card PIN to silence Exit SET CARD READING TYPE Programming Step Keystroke Combination Enter Programming Mode LLL LL Master Code Read EM amp HID card 9 factory default OR Read EM card only 9 4 OR Read HID card only 9 Exit MASTER CARD USAGE Using Master Card to add and delete card users Add a Card User 1 Read Master Add Card 2 Read User Card Repeat Step 2 for additional use
7. r cards 3 Read Master Add Card Delete a Card User 1 Read Master Delete Card 2 Read User Card Repeat Step 2 for additional user cards 3 Read Master Delete Card NOTE e f no Master Cards added must press the Exit Button for at least 10 seconds before release Reset to Factory default the user s information is still retained TO RESET TO FACTORY DEFAULT Power off press the Exit Button hold it and power on there will be two beeps and the LED light turns into orange release the exit button then read any two 125KHz EM card or HID card the LED will turn into red means reset to Factory default successfully Of the two cards reading the 1st one is Master Add Card the 2nd one is the Master Delete Card TRANSMITTER SOLUTIONS WARRANTY The warranty period of Transmitter Solutions keypad is twenty four 24 months This warranty shall begin on the date the keypad is manufac tured During the warranty period the product will be repaired or replaced at the sole discretion of Transmitter Solutions if the product does not operate correctly due to a defective component This warranty does not extend to a the keypad case which can be damaged by conditions outside the control of Transmitter Solutions or b battery life of the keypad This warranty is further limited by the following disclaimer of warranty and liability EXCEPT AS SET FORTH ABOVE TRANSMITTER SOLUTIONS MAKES NO WARRANTIES REGARDING THE GO