1. HYPRO Models 9700B 9700S AQUA TIGER Centrifugal DC Pumps Form L 0335C 1 08 Installation Operation Repair and Parts Manual Description SPECIFICATIONS Body Impeller 9700B Bronze 9700S Stainless Steel Seal 9700B Lip type Viton 9700S Mechanical POM SIZ fcicticcconevesteetanecndinesecddieleeecs 3 4 NPT F Max Temperature ee ceeeeeeeeneeeeeeeeeaes 140 F M x PSl niinniin 7 0 psi Max Current 5 0 Amps WeIQNt irsinin 5 Ibs 2 3 kg approx Motor aaa Stainless steel shaft permanent APPLICATION The Aqua Tiger is suitable for general pumping applications where a flooded intake is provided Typical applications in clude livewell filling and circulation and any other application not requiring a self priming pump magnet fully enclosed ignition protected Performance Chart Model 9700 Aqua Tiger VOLTS PSI_ AMPS GPM 13 5 Alternator Engine Running General Safety Information 1 WARNING DO NOT pump solvents thinners or gasoline as explosion may result causing personal injury or death and or property damage DO NOT use in explosive atmospheres The pump should be used only with liquids compatible with the pump component materials Failure to follow this warning will void the product warranty 2 WARNING DO NOT operate with any of the mount ing bolts removed from the motor case Explosion resulting in personal injury death or property dam age may oc
2. 766 6300 800 424 9776 Fax 800 323 6496 www hypropumps com
3. AL OR CONSEQUENTIAL DAMAGES OF ANY KIND WHETHER FOR BREACH OF ANY WARRANTY FOR NEGLIGENCE ON THE BASIS OF STRICT LIABILITY OR OTHERWISE Return Procedures All pumps or products must be flushed of any chemical ref OSHA Section 0910 1200 d e f g h and hazardous chemicals must be labeled before being shipped to Hypro for service or warranty consideration Hypro reserves the right to request a Material Safety Data sheet from the Purchaser for any pump or product Hypro deems necessary Hypro reserves the right to disposition as scrap pumps or products returned which contain unknown substances or to charge for any and all costs incurred for chemical testing and proper disposal of components containing unknown substances Hypro requests this in order to protect the environment and personnel from the hazards of han dling unknown substances For technical or application assistance call the Hypro Technical Application number 1 800 445 8360 The Hypro Service and Warranty number is 1 800 468 3428 or Hypro Service and Warranty FAX 651 766 6618 Carriers including U S P S airlines UPS ground freight etc require specific identification of any hazardous materials being shipped Failure to do so may result in a substantial fine and or prison term Check with your shipping company for specific instructions P HYPRO Pentair Water Printed in the USA SPRAY GROUP 375 Fifth Avenue NW New Brighton MN 55112 2008 Hypro Phone 651
4. ason for the blown fuse Use the proper wire size as determined by the wiring table Red Wire Fuse Black Wire w Outlet Wiring Table for 9700B Inlet Connection length between battery Wire Gage and motor Fuse Sizes for 9700B METO Meere eaer Eaa 12 Approximate Amp Draw 8 e O A a saieaes dente vnwees ccvedeuuteaed 10 Fuse Size sieniin 10 Models 9700B and 9700S IMPORTANT When ordering parts give PART NUMBER and PART DESCRIPTION Reference oe Numbers are used ONLY to point out parts in the drawing and are NOT to be used as ordering numbers O Ref Qty Model 9700B Model 9700S No Req d Description Part Number Part Number 1 3 Cover Screw 2210 0124 2210 0124 2 Cover 19893 23660 3 O ring Viton 19898 19898 4 Impeller 19892 23659 5 Mechnical Seal Assy N A 23665S 6 Pipe Plug 00336 21059 7 2 Hex Head Screw 2210 0123 2210 0123 8 1 Housing 19891 23627 9 Lip Seal Viton 19928 N A 10 4 Grommet 21138 21138 11 1 Motor 12VDC TENV 23697S 23697S 12 1 Set Screw 19929 19929 TENV Totally Enclosed Non Ventilated Mechanical seals have carbon ceramic wearing faces and 316 Stainless Steel spring components with Viton elastomers Manufacturer reserves the right to change parts without notification Viton is a trademark of E I Du
5. cur Case openings must be sealed to avoid explosion and maintain ignition protected rating 3 Do not pump liquids at temperatures higher than the recommended maximum temperatures 140 F Disconnect power before servicing Drain all liquids from the system before servicing any component Check hose for weak or worn condition before each use Make certain that all connections are tight and secure Periodically inspect the pump and the system compo nents Perform routine maintenance as required see Maintenance section Do not use these pumps for pumping water or other liquids for human or animal consumption Hazardous Substance Safety Information 1 Always drain and flush the pump before servicing or disassembling for any reason see instructions 2 Always drain and flush pumps prior to returning unit for repair 3 Never store pumps containing hazardous chemicals 4 Before returning the pump for service repair drain out all liquids and flush the unit with neutralizing liquid Then drain the pump Attach a tag or include a written notice certifying that this has been done Please note that it is illegal to ship or transport any hazardous chemicals without United States Environmental Protection Agency Licensing Installation and Operation The pump must be mounted in a dry location The motor is not waterproof therefore it must not be submerged The unit can be operated in any positon It is advantageous t
6. he seal area and press the seal out of the seal bore make contact A small amount of grease on the o ring will ease installation Place the o ring on the cover Align the cover with the housing and secure it with the 3 three cover screws 3 4 NPT Rotation lt aza 14 GA Wire Inlet amp Red A Outlet 4 31 14 GA Ports Wire Black 2 75 6 84 Dimensions are in inches Care of the Pump AFTER USE PUMP CARE A GUMMING Gumming or corrosion inside the pump automobile radiator antifreeze containing a rust inhibitor can be prevented by thoroughly flushing the pump clean and then preventing air from getting in the pump Use a with water or a liquid that will neutralize the liquid pumped 50 50 solution of antifreeze and water Flush it through the For many liquids a solution of 1 gallon ammonia mixed pump and then drain it Plug the ports to keep air from with 6 gallons of water works well getting into the pump during storage Cleaning and rust B To PREVENT RUST CORROSION we recommend protection should be done when the pump will be stored after Step A flushing the pump with permanent type away for more than two to three days Limited Warranty on Hypro Pumps and Other Hypro Products Hypro warrants to the original purchaser of its products the Purchaser that such products will be free from defects in material and workman ship under normal use for the period of one 1 year for all products except oi
7. l crankcase plunger pumps will be free from defects in material and workmanship under normal use for the period of five 5 years and accessories will be free from defects in material and workmanship under normal use for the period of ninety 90 days In addition Hypro warrants to the purchaser all forged brass pump manifolds will be free from defects in material and workmanship under normal use and from damage resulting from environmental conditions for the life of the pump Normal use does not include use in excess of recommended maximum speeds pressures vacuums and temperatures or use requiring han dling of fluids not compatible with component materials as noted in Hypro product catalogs technical literature and instructions This warranty does not cover freight damage freezing damage normal wear and tear or damage caused by misapplication fault negligence alterations or repair that affects the performance or reliability of the product THIS WARRANTY IS EXCLUSIVE HYPRO MAKES NO OTHER WARRANTY EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Hypro s obligation under this warranty is at Hypro s option to either repair or replace the product upon return of the entire product to the Hypro factory in accordance with the return procedures set forth below THIS IS THE EXCLUSIVE REMEDY FOR ANY BREACH OF WARRANTY IN NO EVENT SHALL HYPRO BE LIABLE FOR ANY INCIDENT
8. o mount the pumps so the water dripping from a loose port connection will not wet the motor The pump head may be mounted at 90 increments on the motor to allow mounting as needed OPERATION Try not to run the pump dry because doing so shortens the seal life If you must run the pump dry do so only for short periods of time The pump may run against a closed outlet Small particles will pass through the pump so a 50 mesh intake strainer should be fitted to the pump CAUTION The motor runs hot up to 180 F on the motor case Contact during operation may cause a burn Overload ProtectedO Distribution Panel ELECTRICAL HOOKUP WARNING If the pump is operated in an area containing flammable vapors wire leads must be joined by insulated mechanical locking connectors Loose or inadequate wire connections can spark resulting in explosion Property damage injury or death may occur CAUTION Lead wires on the motor must not be short ened or the warranty will be voided Positive terminal of the battery is connected to an overload protected distribution panel The red lead with the fuse holder is connected to the distribution panel The black wire is con nected to the negative terminal of the battery For proper operation the motor must rotate clockwise when viewed from the pump end The proper sized fuse has been installed in the fuse holder If this fuse blows replace it with the same size fuse after determining the re
9. pont deNemour and Company Maintenance MAINTENANCE ASSEMBLY Check all electrical and plumbing connections periodically 1 From the rear of the housing press the seal into the In salt water applications corrosion of the electrical connec seal bore with the open lip toward the pump cavity tions can cause a loss of performance or non operation The 2 Apply a small amount of grease to the motor shaft in the motor should be protected with a corrosion inhibiting spray area where the seal contacts it Slide the housing onto Any rust should be removed and the motor repainted the shaft and secure it to the motor with the 2 two hex head screws DISASSEMBLY 3 Align the impeller set screw with the flat on the motor 1 Remove the cover screws cover and o ring shaft and slide the impeller onto the shaft until it con 2 Remove the pipe plug on the side of the housing and tacts the rear of the housing Slide the impeller forward rotate the impeller so the set screw aligns with the plug 1 32 1 16 and secure it with the set screw Rotate the hole Insert a 3 32 allen wrench through the plug hole impeller by hand to ensure that it does not rub on the and loosen the impeller set screw Remove the impel housing Reinstall the pump plug in the housing ler 4 Clean the surfaces of the cover and housing where they 3 Remove the screws that secure the housing to the mo tor and remove the housing 4 From the inside of the housing insert a dowel into t