        Pressure Reference Type E USER MANUAL
         Contents
1. Pressure Reference  Type E    USER MANUAL    Digital Manometer with Max   Min  Display   Accuracy  0 5  FS typ     The Reference Type E has two operating keys     The left key is to turn the instrument on and  to execute its functions    the functions appear successively on   the display as long as the key is pressed and  are executed when releasing the key      The right key is used to switch between the MAX    and MIN  value     After turn on  the instrument displays the pressure range  for two seconds before changing into the measuring mode     The instrument has the following functions     RESET  Max   Min  value are set to the actual pressure  OFF  Turns off the instrument   ZERO  Sets a new Zero reference   CONT  Deactivates the automatic turn off function     this function is activated with factory settings   meaning the instrument automatically turns off    15 min  after the last key function     Notes        E       SIKA    gegr  1901  Dr  Siebert  amp  K  hn GmbH  amp  Co  KG                1  If the ZERO  and or CONT function is activated  it is indicated on the display  In order to  reset the Zero to factory setting and or to reactivate the automatic turn off function  press    the left key until ZERO and or CONT disappears     2  lf the actual pressure goes beyond the measuring range  OFL  overflow  appears on the  display   SIKA  Dr  Siebert  amp  Kuhn GmbH  amp  Co  KG  Struthweg 7 9  34260 Kaufungen  Germany 1 2    Tel   49 5605 803 0  Fax   49 5605 803 54  em
2. ail  info SIKA net  web  www SIKA net       i       SIKA    gegr  1901  Dr  Siebert  amp  Kuhn GmbH  amp  Co  KG          Installation     The Reference Type E has 7 16    UNF male thread and is delivered complete with an O ring seal  swivel fitting which allows Reference Type E to be rotated through 360      Only minimal tightness is needed to seal up to 350 bar  Process pressure connection   is G 1 4    male     process connection G1 4       Battery Change     When the battery starts weakening  a low battery warning  BAT LOW  will appear in the upper left  corner of the display  For battery change  open the battery compartment and change the battery   tyoe CR 2430   The battery life is 1400 hours in normal measuring mode     Ranges   Calibration     The factory setting of the Zero for the range  1   40 bar is at 0 bar absolute  For sealed gauge  pressure measurements  activate    ZERO SEt    at ambient pressure    Instruments with the range 0   850 bar are calibrated in a sealed gauge mode with 1 bar absolute  pressure as a Zero reference     Digital reference test gauge  Pressure medium fluids and gas media  Pressure connection G1 4   male  Display multi purpose LCD  30 x 30 mm  Function keys  SELECT   reset  off  zero  cont   MIN MAX     Casing 70 x 100 x 30 mm  d xh x w   IP65  weight approx  130 g  rubber cap  Power supply 3 V battery  1400 h service life continuous operation  LOW BAT display  AUTO Off  Accuracy    0 5   FS    1 digit    Measuring range Resolution  Mode
3. l A 30 40 bar 0 01 bar  Model B 0    300 350 bar 0 1 bar    Option EEx ia IIC T5 T6   O1LATEX6001X       SIKA  Dr  Siebert  amp  Kuhn GmbH  amp  Co  KG  Struthweg 7 9  34260 Kaufungen  Germany 2 2  Tel   49 5605 803 0  Fax   49 5605 803 54  email  info SIKA net  web  www SIKA net    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  Optoma EP735 User Guide Manual  Page 1 Page 2 手動圧着工具取扱い説明書 手動圧着工具は小量生産  Targus 15" Vertical Slip Case  DAQFactory - LabJack Application Guide  テレビクイックガイド(303KB)    Manual de usuario de medidor multi  SPS6000 Datasheet - A-Tech Instruments Ltd.  81064102 焚火ピラミッドグリルEVO-L    Copyright © All rights reserved. 
   Failed to retrieve file