1. This equipment has been tested and found to comply with the limit for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with these instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help CAUTION Signal cables must be used with this device to ensure compliance with Class B FCC limits CAUTION Any changes or modifications could void the authority granted by the FCC to operate this equipment K01 3612000 03 Remote Site Products 1 888 532 2706 www remotesiteproducts com http www remotesiteproducts com p 778 Cyber CS36A12V2 DC UPS 12 VDC 2A W 7 2AH Battery aspx
2. ction routine Upon Connector Type Insulation Displacement Connector IDC alarm failure an alarm signal will be sent Battery Low Battery Battery LED Flash 1 2 sec beep Open When battery capacity is lt 45 approximately every 15 sec 12Vdc unit signals low battery Battery Type Sealed Maintenance Free Lead Acid Battery Batte Tvpe Numbers of Battery 7 2Ah 12V ry yp Auxiliary Input Power 12Vdc 1 3mm COAX Power Jack The battery is a standard sealed lead acid battery rated at 12Vdc 7 2Ah If required the battery may be replaced with an approved 12Vdc 7Ah battery Indicators AC Power Auxiliary Power Source OY Replace Battery Batteries are considered HAZARDOUS WASTE and must be disposed of properly VO Most retailers that sell batteries collect used batteries for recycling Battery System Alarm AC Fail Replace Battery Pb Replace Battery aye Low Batte Auxiliary Power Connection AUX lt n y CS36D12V Battery Replacement Specification E oni Warning Diagnostics Step 3 a Place screw in keyhole screw slot and tighten half way Slide unit so that the screw rests o Connection point for customer supplied DC input voltage 12Vdc At 45 remaining capacity the CS36D12V switches from internal battery to external source The auxiliary power source supplies power Communication Interface Signal Retun On Battery back of the pow
3. er connector cover against the narrow end of the slot Place second screw into the screw hole and tighten securely p oo Close the power connector cpmpartment cover NOTE Please use appropriate size screws to mount the CA50A48V2 on the wall NOTE Recommended screw size Self tapping screw M4x20L Truss head CS36D12V Installation Guide Step 1 a Press the battery cover release latch A and slide the cover to remove Step 2 b Remove the 9 pin connector compartment cover by pulling outward b a Insert the power and interconnection cables into the back cable channel Feed the cable end into the 9 pin connector compartment Securely mount the unit on the wall with 2 mounting screws NOTE Please use appropriate size screws to mount the CS36D12V on the wall NOTE Recommended screw size Self tapping screw M4x20L Truss head Step 3 a Remove protective shipping terminal covers from the battery if necessary b Connect the battery cable leads to the appropriate terminals red to postive black to negative c Insert the battery into the battery compartment d Install the 9 position IDC connector to the unit see Fig 1 Step 4 Signal Return On Battery Replace Battery AMissing Battery Low Battery a Install both power and interconnection cables to the 9 position IDC connector See case for the pin assign
4. ire to negative b Thread the power cable along the Wrap the power cable around the strain relief lip Insert the cable hrough one of the cable slots to exit the compartment c Insert the power cable into one of he cable channels on the back of he unit 1 Battery Compartment Cover 2 Control Buttons Alarm Silence Battery Emergency Use 3 LED Indicators Auxiliary Power Source Replace Battery Battery Power System Status 4 Battery Compartment 5 9 Pin Conductor Compartmemt Cover 6 Battery Release Latch 7 Interconnection amp Power Cable Channel 8 Keyhole Screw Slot 9 Pass Through Hole for Interconnection amp Power Cable Operation Guide Start Up Plug the CA50A48V2 power supply into AC power The unit is now ready to be placed into service The CS36D12V has four LED indicators and two control buttons The table below lists the functions of each LED Indicators Indicator Condition Alarm Silence Button Blue Press and hold the button for 1 second to silence the audible alarm Battery Emergency Blue Press and hold the button to activate emergency battery capacity Use Button Auxiliary Power Source Green _ Indicates that an external power source with adequate voltage 3 Step 1 Step 2 12Vdc is connected to the CS36D12V a Press battery cover catch A and slide the cover to the left a Replace battery cable on the new battery Replace Battery Red Battery replaceme
5. ments b Close the 9 pin connector compartment cover c Close the battery cover The UPS battery charges when it is connected to utility power The battery charges fully during the first 24 hours of normal operation Do not expect full battery run capability during this initial charge period Tighten keyhole slot screw securely Replace Battery Missing to the load ONT in the event of 48V input voltage failure and a battery capacity of lt 45 Battery Low Battery F Physical Maintenance Mode Maximum Dimensions L W D 5 94 x 2 65 x 1 56in 6 89 x 6 75 x 3 47 in Maintenance mode determines remaining useful battery life During the 16 hour test the battery is Weight Ib 0 77Ib 1 51lb discharge to determine its state The unit measures the rate of change in the battery charge If the rate of discharge is excessive the battery replacement indicator is activated e The CS36D12V enters the maintenance mode approximately once every 45 days e In the event that the CS36D12V is in the maintenance mode and an AC failure occurs maintenance mode will cease and the CS36D12V will supply the power to the load FCC NOTICE Environment Operating Temperature 49F 115 F 20 C 46 C Operating Humidity 0 95 noncondensing within enclosure Max Operating Elevation 10 000ft 3 000m Max Storage Elevation 50 000ft 15 000m Storage Temperature 49F 113 F 20 C 45 C
6. nt required Alarm will beep once every 15 minutes to remove b Place the new battery into battery compartment z 7 z F b Remove the battery connector see Fig 2 c Close the battery cover Battery Power Green Indicates the battery is supplying the power At 45 battery capacity amp Remove ihe balter stain release alch 19 remove balen this LED will flash and then alarm will beep 4 times per minute System Status Green Indicates normal mode of operation Status LED Alarm amp Communication Signals Condition Status LED Alarm Interface Description Normal System LED On All communication Condition normal AC power load charges battery Input signals in Low state Battery is connected and in good condition Voltage Range 120Vac 48Vdc ON Battery Battery LED On Open 48V input failure or loose connection between Frequency Range 50 60Hz power supply and battery board battery is supplying the power Output Replace Battery Replace Battery 1 2 sec beep Open Every 45 days the unit will automatically initiate a Output Voltage Normal 48Vdc 12Vdc LED On every 15 min battery test The test lasts 16 hours if the battery Output Voltage Battery Mode 10 5 20Vdc needs to be replaced an alarm signal will be sent to Output Power Max 48W 34W the Central Office Battery Missing Nore only Open Approximately 6 seconds after battery removal the Ripple less than 200 mV ON sees system initiates battery dete
7. s during the installation of this device 1 Carry out the installation in a safe area that is free of excessive dust and has adequate airflow 2 Screws must be appropriate for total weight of the UPS unit and the mounting surface material 3 Do not operate the UPS where the temperature and humidity are outside the specified limits Refer to specifications in this manual OVERVIEW CA50A48V2 2 tol Hy 3 I 1 Power Connector I i Compartment Cover I I 22 Strain Relief Lip i i V 3 2 Pin IDC Connector 4 Power LED Indicator l 5 Screw Hole 6 Keyhole Screw Slot i i 7 Cable Channel i 8 Input Power Cord 8 ft a z z CA50A48V2 Front CA50A48V2 Back OVERVIEW CS36D12V HO 8q E 3 4 5 6 CS36D12V Back CA50A48V2 Installation Guide Step 1 a Open the power connector compartment cover ZAM a Step 2 a Install output power cable to the 2 position IDC connector red wire o positive black w
8. x RSP User s Manual for CS36A12V2 Bundled Kit CA50A48V2 CS36D12V IMPORTANT SAFETY WARNINGS SAVE THESE INSTRUCTIONS This manual contains important instructions regarding the installation and operation of this device Read this manual thoroughly before attempting to unpack install or operate this device CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce the risk of electric shock do not remove the cover except to service the battery No user serviceable parts are inside except the battery CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions CAUTION This unit must be wall mounted Do not use the unit unless it is mounted correctly INTRODUCTION The CS36A12V2 provides increased flexibility and cost effectiveness by separating the power supply unit CA50A48V2 from the battery back up unit CS36D12V The power supply plugs into a 110 120Vac outlet It converts the power to 48Vdc which is then fed through a power cord to the battery back up unit The battery back up unit feeds 12Vdc to the ONT SYSTEM BLOCK DIAGRAM O CA50A48V2 Power Supply CS36D12V Battery Back Up 110 120Vac INSTALLATION Carefully follow these instruction

Download Pdf Manuals

image

Related Search

Related Contents

取扱説明書  Puma new - CNH Industrial  Réalisation d`une application de gestion de production: Rapport de  User`s Manual  User`s Manual 8kW Fast Charging Battery  1 Introduction - Applicaties Helpdesk Water  Propuesta Desarrollar una aplicación (programa) utilizando el  P45A Series Motherboard User's Manual  Eurocom Racer User Guide Manual  取扱説明書 - MotoGear.jp  