1. E SYMCOD TermiCom X7 15 and 19 User Manual Documentation Version 26 09 2012 WEB site www symcod com E mail support symcod com TermiCom X7 Warranty Symcod warrants its products to be free from defects in material and workmanship during one year from the purchase date If a product proves to be defective in material or workmanship during the warranty period Symcod will at its choice repair or replace the product with a similar product Replacement Product or parts may include remanufactured or refurbished parts or components The replacement unit will be covered by the balance of the time remaining on the customer s original limited warranty Symcod provides no warranty for the third party software included with the product or installed by the reseller distributor customer or any other party Warranty does not include Any product on which the serial number has been defaced modified or removed Damage deterioration or malfunction resulting from Accident misuse neglect fire water except for waterproof units lightning or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product Repair or attempted repair by anyone not authorized by Symcod Damage to or loss of any programs data or removable storage media Software or data loss occurring during repair or replacement Any damage of the product due to installation of the product
2. Jx Jx x x Ix TermiCom X7 Option 802 11B Maximum temperature IMPORTANT Do not cover while the unit is ON The back of the TermiCom should not be placed flat on a table while the unit is ON Keep the surfaces of the TermiCom free of any material and respect a minimum clearance of 2 between the back of TermiCom and of any surface in order to allow the dissipation of the internal heat 5 ba aol a E O c it cD Q O Relative humidity without Storage temperature C condensation Note2 20 60 o o oy OH CO The casing is not designed to be watered However the front is water tight and therefore will resist dripping and splashing Z gt TermiCom X7 WWW SYMCOD COM SYMCOD Dimensions in inches for the 15 and 19 TermiCom X7 15po Top view Side view Side view wall mount table mount 445 la 13 26 TermiCom X7 19po Top view Side view Side view wall mount table mount 8 03 2s 19 42 Z gt TermiCom X7 WWW SYMCOD COM SYMCOD Power TermiCom X7 is powered through an external 12 VDC power supply which connects to a 120 240VAC power network Power cable and power supply are provided with the unit A WARNING powering Before installation please turn off powering source Plug the unit only when the installation is completed A WARNING earth ground Make sure that equipments and the TermiC
3. Causes external to the product such as electric power fluctuations or failure Use of supplies or parts not meeting Symcod specifications Failure of owner to perform periodic product maintenance as_ stated in documents supplied Any other cause which does not relate to a product defect Damage caused by static Removal installation freight and set up service charges WWW SYMCOD COM Warning A Safety amp reliability page 3 Powering page 8 Earth ground page 8 Installation amp handling page 10 Cleaning page 20 SYMCOD Disclaimer The material on this document is intended for end user distributor and or reseller use Although downloading and printing documents is allowed Symcod will not be responsible for any modification or any other use of any content in the displayed downloaded material Please note that all documents are subject to change without notice and are occasionally revised to specify correct or revise the content or for other purposes Therefore the version displayed on the site may differ from your original printed copy Please contact us if you require assistance Symcod Inc assumes no liability for damage incurred directly or indirectly errors omissions or discrepancies between the device and the manuals or documents supplied Symcod is not responsible for any loss or damage Including data corruption interruption of operation lost business information lost production etc cause
4. following result Protected Volume Configuration Type DISK State DISABLED Boot Command NO_CMD 16 lt lt 5 TermiCom X7 WWW SYMCOD COM SYMCOD Param 1 0 Param2 0 Persistent Data Volume ID D202 96 49 00 OE 59 96 02 00 00 00 00 00 00 00 Device Name __ Device Harddisk Volume4 Max Levels 3 Clump Size 512 Current Level 1 Disk space used for data 0 bytes Disk space used for mapping 0 bytes Memory used for mapping 0 bytes nn The following example shows how to enable EWF for drive C ewfmer c enable EWF manager displays the Enable command as pending The command does not execute until the next boot EWF manager displays the following result Protected Volume Configuration Type DISK State DISABLED Boot Command NO_CMD Param 1 0 Param2 0 nn Persistent Data Volume ID D2 02 96 49 00 OE 59 96 02 00 00 00 00 00 00 00 Device Name Device HarddiskVolume4 C Max Levels 3 Clump Size 512 Current Level 1 Disk space used for data 0 bytes Disk space used for mapping 0 bytes Memory used for mapping 0 bytes Enabling overlay Protected Volume Configuration Type DISK State DISABLED Boot Command ENABLE Param1 0 Param2 0 nn Persistent Data Volume ID D2 02 96 49 00 OE 59 96 02 00 00 00 00 00 00 00 Device Name Device HarddiskVolume4 Max Levels 3 Clump Size 512 Current Level 1 17 a sp TermiCom X7 WWW SYMCOD COM SYMCOD The following example shows how to check the status type of the EW
5. it is recovered Note that the volume must currently be protected Otherwise the error message The system cannot find the drive specified is displayed Displays usage and help Displays help information for a specific FBWF Manager switch If no switch is provided the FBWF Manager displays all the configuration information just like the DisplayConfig switch The following table describes the input parameters Input field Meaning volumename Full path to a volume 1 Remove exclusion list 0 Preserve exclusion list Full file or directory path including the drive letter Please note that file names are passed to fowfmgr as a command line argument which means path backslashes and double quotes are interpreted differently For example file name becomes simply file name because the first backslash acts as an escape character To get file name specify V file name on the command line threshold Overlay threshold in MB dl Z gt TermiCom X7 WWW SYMCOD COM SYMCOD Recommendations Ethernet Before proceeding with the wiring installation please consult Ethernet wiring and recommendations TCPIP available at www symcod com Installation Do not cover while the unit is ON The back of the TermiCom should not be placed flat on a table while the unit is ON Keep the surfaces of the TermiCom free of any material and respect a minimum clearance of 2 between the back of TermiCom and of any surface
6. load the system as usual Because Hibernate Once Resume Many environments are supported in EWF RAM and RAM Reg modes you can use the ewfmgr commitanddisable live command which saves the runtime image from the EWF overlay to the persistent image on the system In some cases this is not desirable as it commits the whole cached image To apply a specific set of changes to the system you can disable EWF disable HORM apply changes and re enable HORM To disable EWF in a Hibernate Once Resume Many environment 1 Disable EWF by using the EWF Manager command for example ewfmer all disable Deactivate HORM by using the EWF manager command for example ewfmgr all deactivatehorm Restart the system After EWF is disabled you can apply updates or install applications to your run time image To re enable Hibernate Once Resume Many see Enable a Hibernate Once Resume Many Environment by Using EWE 19 TermiCom X7 FBWF eo ID e WWW SYMCOD COM SYMCOD FBWEF File Based Write Filter protects the specified files folders and or volumes FBWF Manager Command Line Syntax The FBWF Manager command line syntax follows fbwfmer help switch displayconfig overlaydetail enable disable addvolume volumename removevolume volumename 110 addexclusion path removeexclusion path setthreshold threshold setcompression 110 setpreallocation 110 commit volumename fi
7. uses cable UTP Cat5 a maximum of 300feet 91 44 meters of cable is allowed between the hub and or the switch and the TermiCom For more details concerning wiring please download the document WIRING AND EXAMPLE OF CONFIGURATION TCPIP available on www symcod com 13 TermiCom X7 WWW SYMCOD COM SYMCOD TermiCom X7 configuration Operating system The operating system of TermiCom X7 is Windows Embedded Standard 7 WES7 which is an embedded version of Windows 7 The Windows Embedded Standard 7 included in the TermiCom X7 is specifically designed to work with it and cannot in any case be transferred on another computer This section covers some particularities of our WES7 operating system Excluding that the whole system operates as a Windows 7 system If you don t find in this document the information you are looking for please refer to the Microsoft documentation If a specific configuration or application is working on a Windows 7 system and doesn t work on our WES7 please contact us support symcod com System Restore A USB disk having the unique task of performing a restoration of the system in case of failure is integrated in the unit To reinstall WES7 follow these steps l Power on the unit 2 Enter BIOS setup by pressing DEL at startup 3 Enter Advanced BIOS Features menu 4 Select Hard Disk Boot Priority and press ENTER 5 Move USB HDD0 to priority 1 6 Press F10 then ENTER to save and quit 7
8. F volume ewfmer EWF manager displays the following result Overlay Configuration Volume Size 2048030208 Segments 8192 Segment Size 249856 Free segments 8192 Max Levels 3 Max Protected Volumes 1 Protected Volumes 1 Overlay volume percent full 0 00 Protected volumes Arc Path Device Harddisk Volume4 Note If EWF is disabled the current level is shown as N A HORM HORM Hibernate Once Resume Many uses the hibernation file hiberfile sys to always start in the same state In the event of a system shutdown whether it is planned manual shutdown or not power failure on the next boot the system will be identical This method will also significantly reduce the boot up time of the computer The size of the hibernation file created will be the same as the RAM Enable a Hibernate Once Resume Many Environment by Using EWF To enable a Hibernate Once Resume Many environment that uses EWE 1 Make sure that your system supports hibernation You can use the Powercfg Command Line Options command line tool to enable hibernation powercfg h on 2 Use the EWF Manager command line tool to verify that EWF is enabled Ewfmer all 3 If EWF is enabled go to the next step Otherwise enable EWF For example ewfmer all enable Important You must use the all command because HORM has a requirement that all volumes must either be protected with EWF or be in unmounted state when the Hibernate Once occurs This is to prevent stat
9. Follow the steps on screen After the Restore 1 Reboot unit 2 Enter BIOS setup by pressing DEL at startup 3 Move ChO M to priority 1 4 Press F10 then ENTER to save and quit 5 The system will complete its installation please wait HyperTerminal The communication and terminal emulation tool HyperTerminal since always offered with the Windows operating systems is no longer available with version 7 As a replacement we installed TeraTerm v4 71 that can be accessed from the Start menu Built in Administrator account By default the Administrator account is disabled in Windows 7 for security purpose In the event that the use of this account would be essential it is possible to enable it that way Access Control Panel Administrative Tools Computer Management In the left pane open Local Users and Groups then select Users In the right pane open Administrator and uncheck Account is disabled box The Administrator account will now be available from the Welcome Screen 14 or a TermiCom X7 WWW SYMCOD COM SYMCOD The default password is Administrator To disable the Administrator account again go back to Computer Management and simply check Account is disabled box in the Administrator account properties Run as Administrator Certain applications must be run as Administrator to be able to successfully complete every tasks For a single or occasional use of such application the right button of the mouse on the applicati
10. d by use non use or misuse of any of the information contained in this document Symcod Inc is not responsible of the content or validity of the links gave as references for other products not manufactured by Symcod Inc Documents include instruction book user guide operating instructions manuals safety precautions instructions data sheets or any other documents supplied by Symcod TermiCom X7 WWW SYMCOD COM SYMCOD IMPORTANT Read me first By carrying out the installation and the use of this equipment you accept the rules and limitations described in this document or any other document relating to this product By carrying out the installation and the use of this equipment you are presumed having read all the safety warnings A A WARNING Safety and reliabilit SYMCOD Inc will not be responsible for the use of this equipment for other purpose then data collection This equipment is designed and intended for an industrial and commercial use only The TermiCom X7 is not for a residential use M TermiCom X7 WWW SYMCOD COM SYMCOD TermiCom X7 TermiCom X7 is a microcomputer specifically designed for dusty industrial environment without watering The casing of the X7 is made of aluminum which gives it his lightness and resistance The TermiCom X7 is provided with a Atom 1 6 GHz processor a TFT 15 19 color touch screen LCD and a solid aluminum stand which allows desktop or wall mount installation in only a few mi
11. e How to install TermiCom X7 Desktop position a AA Wallmount position D Base support Figure 1 Base support of TermiCom X7 Side view 1 Determine the appropriate location plane amp motionless surface Be sure to choose a fixed and solid plane surface able to support the weight of the TermiCom 2 Each side of the base support D screw A wall mount or screw B desk top screw C see figure 1 3 Separate the base support D from the TermiCom X7 e Fix the base support D at the chosen location e Place TermiCom X7 back on its base support in the desired position Wall mount or desktop and put the corresponding screw A for wall mount B for desktop e Tighten the screws on each side of the base support A WARNING installation amp handlin Choose a fixed and solid plane surface able to support the weight of the TermiCom approximately 10 Pounds 4 54Kg Handle the TermiCom safely in order to avoid any back wound 10 Z gt TermiCom X7 WWW SYMCOD COM SYMCOD Mounting variants The TermiCom X7 is always sent with its support installed at the bottom of the unit and in Wall mount position However it is possible to change the location and position of the support to respond to different needs Here are some examples of mounting variants If the support provided with the unit doesn t fit your needs you can make your own support using the same mounting holes at the back of the casing Here are di
12. e synchronization problems Each Resume from hibernation expects the entire system to be in exactly the same state as when the Hibernate Once occurred 4 Restart the system 5 Activate HORM by using the EWF Manager command line tool ewfmer c activateHORM 6 Open applications and start any processes that you want to be running on the system when it resumes from hibernation 18 ET sb TermiCom X7 WWW SYMCOD COM SYMCOD 7 Hibernate the system shutdown h 8 Restart the system After you restart the system EWF is enabled In the event of an Autologin when Windows is resuming from hibernation it may happen that the user is locked Selecting the user will start the session but there is a way to prevent this inconvenience and make the session start automatically as it is supposed to To do this access Control Panel Power options In the left pane select Require a password on wakeup then select Don t require a password When the HORM is activated changes that do not require to restart the system can be applied Once changes are done simply re hibernate Disable EWF in a Hibernate Once Resume Many Environment If you want to make changes or apply updates to your run time image in a Hibernate Once Resume Many HORM environment you must first disable Enhanced Write Filter EWF Because the Boot Environment loads the hibernation file before it reads the pending EWF Manager start commands you must disable EWF and
13. ftware Resistive touch screen Flash disk Can function with finger or object pressure pencil Data storage piece made without any mobile hardware element Can store data over several years without being powered by electricity External device connected to the central processing unit Can ensure the entry or Peripheral the exit of data Computer basic software intended to order the execution of programs by ensuring the work management the input output operations on peripherals the resource allocation to the various processes the access to program libraries and files as well as the accountancy of work Operating system Service and support Support Please use EMAIL for your requests gt For technical questions hardware and software email at support symcod com e Provide a detail description of the problem and or questions intermittent problem happens when e Please indicate model number and serial number if applicable gt For all other questions please use symcod symcod com or Symcod Inc at 1171 Notre Dame O Victoriaville Qc G6P 7L1 Phone 1 800 203 9421 1 819 751 0095 Fax 819 751 1292 Return Merchandise Authorisation RMA All return request must be authorized by SYMCOD Inc To do so please refer to the following http www symcod com rma e You will receive a formal confirmation number RMA e The RMA number must be printed on each box e All freight charges are at the customer e
14. he overlay without having to reboot the system For example ewfmer c commitanddisable live Note Live commit and disable is not supported for disk overlay Allows the user to associate an ASCII string with an overlay level This command can Description be combined with the SetLevel command Disable Disables the overlay on the specified protected volume Enables the write filter so that data that is written to the protected media is cached in Enable the overlays The current overlay level becomes 1 as soon as EWF is started and a new overlay is created at level 1 NoCmd Clears the current pending command Restore Restores to the prior overlay Same as SetLevel Current Overlay Level 1 Sets the current overlay level to the specified level Valid values for levels are e Current overlay level 1 Starts a new overlay level SetLevel e 0 Current overlay level Sets the level discarding all data above the specified level e Level Deletes all the data in the specified level and beyond ActivateHorm Enables HORM DeactivateHorm Disables HORM Because EWF manager commands are executed on the next boot you must reboot the system for a command to take effect Examples The following examples refer to a system on which EWF is configured to protect drive C and on which the EWF partition resides on disk 1 partition 3 The following example shows how to check the EWF status and format ewfmer c EWF manager displays the
15. in order to allow the dissipation of internal heat TermiCom X7 maintenance A craning Painted aluminium may react to some chemical agents in particular with ammonia and with products containing hydroxide or certain acids Clean it with a soft soap to prevent the damage of the case Once in a while use air blast to remove dust Certification This equipment has been found compliant to class A Part 15 of FCC Rules These limits are intended to get a reasonable protection against dangerous interferences when the equipment is used in an industrial or commercial environment This equipment emits uses and can generate radiations of radio frequencies and can cause dangerous interference for radio communications if it is not used in accordance with the instruction manual The use of this equipment is not planned for a residential use Z gt TermiCom X7 WWW SYMCOD COM SYMCOD Accessories amp options r f Ta Figure 5 1 Tool balancer 2 Powerscan scanner Figure 6 1 SKT silicone keyboard Sealed rigid casing OPT 802XPE RF option 802 11b 5 5 dBi antenna 504 00048B Power supply for TermiCom XPe X7 for replacement Be lt gt TermiCom X7 WWW SYMCOD COM SYMCOD Dictionnary Automatic procedure that allows checking or validating the identity of a person or Autologin the identification of any other entity during an electronic exchange to control network access system information processing or so
16. lepath restore volumename filepath The following table describes the command line switches Switch displayconfig overlaydetail enable disable addvolume removevolume addexclusion removeexclusion setthreshold setcompression setpreallocation Description Displays all configuration information for the write filter including protected volumes list overlay configuration and write through paths The command returns State Indicating current filter state enable or disable and state for next boot Protected Volumes List of protected volumes including the current and next boot state Compression Current and next boot state for cache compression Threshold Current and next boot values for the overlay cache threshold Write Through Paths Displays a complete list of active and next boot write through paths Pre allocation Status Displays current and next boot status for cache pre allocation Displays detail on the current overlay contents for all protected volumes The command returns Contents Files and folders currently in the overlay for all protected volumes including sizes size of data in overlay and open file handles Memory Usage Total amount of memory being consumed by the overlay Enables the write filter on the next restart Disables the write filter on the next restart Adds a volume to the protected volume list for next boot Removes a volume from the protected volume list for next bo
17. mensions for location of these mounting holes TermiCom X7 15 Mounting Holes 10 60 10 24 thread 8x Max depth 0 25 1 Z gt TermiCom X7 WWW SYMCOD COM SYMCOD TermiCom X7 19 Mounting Holes 10 24 thread 8x Max depth 0 25 12 2 gt TermiCom X7 WWW SYMCOD COM SYMCOD Detailed Specifications The TermiCom X7 is provided with several ports allowing the connection of various types of peripherals according to needs for example printers electronic scales bar code scanners sensors The default orientation of the connectors is downwards but it is also possible to have them upwards if specified on order Figure 2 TermiCom X7 bottom view Power button The power button figure 2 allows the TermiCom X7 to be powered on or off Connectors Audio output Ethernet2 Etherneti COM3 COM 1 Figure 3 TermiCom X7 connectors Power in Allow to connect to a 120 or 240VAC power network external power supply Audio output Allow to plug an external audio output Port SVGA Allow to plug a screen COM 1 2 3 serial port Allow to connect peripherals like printers electronic scales automats with a 9 pins female cable not included USB1 USB2 USB3 USB4 connectors Allow to connect USB peripherals make for A type USB connectors 2 Ethernet connector Allow to communicate through an Ethernet 1Gbit connection with a standard RJ 45 connector As any equipment Ethernet that
18. nutes Several inputs and outputs make possible the addition of peripherals such as industrial keyboard bar code scanner or any other peripherals The flash disk included with the basic version can be completely write protected This feature is used to prevent any modification made by the user that could put in danger the application or the operating system The operating system included in the TermiCom X7 is Windows Embedded Standard 7 WES7 it is directly installed on the flash disk The Ultra Resistant touch screen is offered for usage in environment where there is particularly abrasive dust Unlike the standard touch screens that are covered with a polymer this one is covered with a thin layer of tempered glass which makes it much more resistant to abrasives and even allows it to function with deep scratches You can also use the wireless version of TermiCom X7 by including the WiFi 802 11b g option M TermiCom X7 WWW SYMCOD COM SYMCOD Main characteristics TermiCom X7 15 Color Touch Operating Comm screen LCD System Product i i Storage Inputs Outputs Maximum power consumption without periph 15 Ultra resistant Resistive 32Gig Flash Disk SSD Hard Disk min 80Gig oosoiseresxoo X O x os oisessszoo X O x gt gt 4 Windows Embedded Standard 7 ele Parallel port Audio output ele Serial port O Available Option Recommended for environments with very abrasive d
19. olume specify the drive letter for the protected volume for example ewfmgr c options Specifies the EWF volume boot options The following commands are used to manage protected volume configuration Disable Enable Commit SetLevel Restore Checkpoint Description and Nocmd Remarks The following table shows the Enhanced Write Filter EWF console manager application tool boot commands Boot command Description Displays information about all protected volumes and performs specified commands such as disable enable commit checkpoint and restore on each volume 15 a ID TermiCom X7 WWW SYMCOD COM SYMCOD Checkpoint Starts a new overlay level Same as SetLevel Current Overlay Level 1 Commit Commits all current level data in the overlay to the protected volume and resets the current overlay level to 1 The Commit command can be combined with the Disable command to commit and then disable The overlay is written to the protected volume on the next system boot Committing the overlay can impact the speed of the boot process Commits all current level data in the overlay to the protected volume and disables the overlay The overlay is written to the protected volume on the next system boot Committing the overlay can impact the speed of the boot process Commutand Disable You can use the live command for both EWF RAM and EWF RAM Reg modes to immediately commit the overlay to the protected volume and disable t
20. om casing are properly grounded Options description RF option RF option OPT 802XPE makes possible the use of the TermiCom X7 without network cable The Wi Fi communication supports 802 1 1a b g A minimum 802 11B Wi Fi infrastructure is required Orientation of Connectors Because every installation is different from another and to provide more flexibility the orientation of the connectors can be configured during assembly at our facility By default the connectors will be oriented downwards If specified on order the connectors can be oriented upwards VESA Mounting The VESA mounting is not included with the standard TermiCom X7 but is available as an option P TermiCom X7 WWW SYMCOD COM SYMCOD Desktop or wall mount side view Side view Side view Wall mount version Desktop version Desktop back view yon Back view Back view With Wifi option Z gt TermiCom X7 WWW SYMCOD COM SYMCOD How to install your TermiCom X7 The stand provided with the TermiCom X7 permits to install the unit on a wall or on a table Once fixed the angle of TermiCom X7 can be easily adapted to the need of each user no loosen tighten needed see A TermiCom fixation handling IMPORTANT To allow the evacuation of internal heat the TermiCom should not be covered while ON The back of the TermiCom should not be placed flat on a table or other surfaces Respect a minimum of 2 between the back of TermiCom X7 and any surfac
21. on s icon or its shortcut will give access to this function Tu run an application as administrator all the time use the right button of the mouse on the application s icon and select Properties In the Compatibility tab locate Privilege Level then check Run this program as an administrator box If the box is unavailable to check go in the Shortcut tab click the Advanced button and check Run as administrator box Enhanced Write Filter EWF The Enhanced Write Filter EWF is a built in functionality of the Windows Embedded Standard 7 that allows to write protect the system By default this functionality is disabled The EWF offers 3 methods of protection EWF HORM FBWF The different commands of each method of protection are explained in the following pages from the Microsoft documentation These commands can be run in a Command Prompt window and only as Administrator EWF EWEF protects the whole volume Once enabled all the modifications made to the system are effective in RAM only When the system is restarted everything is back to the previous state The EWF is configured in RAM Reg mode The EWF manager console application is used to control Enhanced Write Filter EWF Manager uses the following syntax EWFMGR lt drive letter gt optional options Parameters drive letter Specifies the volume path This is an optional parameter that is used for protected volume configuration mode To view the status of the protected v
22. ot Adds a write through path to the exclusion list for next boot Removes a write through path from the exclusion list for next boot Sets the overlay threshold value for next boot Sets overlay compression as enabled 1 or disabled 0 for next boot Sets cache pre allocation as enabled 1 or disabled 0 for next boot 20 TermiCom X7 commit restore help switch a WWW SYMCOD COM SYMCOD Commits the changes made to the file to the underlying media The volume name can either be a case insensitive volume device name for example Device HarddiskVolume1 or a drive letter for example C or D Note that the name is not the volume label that Windows Explorer displays before the drive letter The file path must be an absolute path starting with Note that the volume must currently be protected Otherwise the error message The system cannot find the drive specified is displayed Discards the changes made to the file that is restores the files to its original contents from the underlying media The volume name can either be a case insensitive volume device name for example Device HarddiskVolume1 or a drive letter for example C or D Note that the name is not the volume label that Windows Explorer displays before the drive letter The file path must be an absolute path starting with It must be a file It is acceptable that the file was deleted in which case
23. ust screen covered with a fine layer of tempered glass allows operation with deep scratches Environmental specifications Operating temperature Relative humidity without Storage temperature C condensation RH TermiCom X7 xj TermiCom X7 Option 802 11B xj x Jx x x Q0 Maximum temperature IMPORTANT Do not cover while the unit is ON The back of the TermiCom should not be placed flat on a table while the unit is ON Keep the surfaces of the TermiCom free of any material and respect a minimum clearance of 2 between the back of TermiCom and of any surface in order to allow the dissipation of the internal heat The casing is not designed to be watered However the front is water tight and therefore will resist dripping and splashing ne TermiCom X7 WWW SYMCOD COM SYMCOD Main characteristics TermiCom X7 19 Color Touch Operating Comm screen LCD System Product i i Storage Inputs Outputs Maximum power consumption without periph 15 Ultra resistant Resistive 32Gig Flash Disk SSD Hard Disk min 80Gig osos X O x soise s20 X O x gt lt gt 4 Windows Embedded Standard 7 ele Parallel port Audio output ele Serial port O Available Option Recommended for environments with very abrasive dust screen covered with a fine layer of tempered glass allows operation with deep scratches Environmental specifications x
24. xpense and responsibility Please take note that collect package will be refused e Goods must be returned in their original packaging or an appropriate packaging products damaged during transport are not covered by warranty 24

Download Pdf Manuals

image

Related Search

Related Contents

StorageTek StorageNet SCSI-3 User's Manual  Triton  CNGE FORMATION - Collège National des Généralistes Enseignants  Linux Journal  Notice_ECX_Circuit_1-10 - Absolu  precaución - KellySolutions.com  取扱説明書(印刷用PDF)  "取扱説明書"  Drum Amplifier User Manual  + Te st d e d é p ista g e d e l`in fe c tio n à H . p ylo ri  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.