1. Weather Station Touch Screen For more information regarding this product and to view the full Weather product range please scan the QR code with your mobile device Instruction Manual 4 N Product Code WS109A a nan Table of Contents Package Contents Below General Information 1 Specifications 1 Glossary 2 Glossary of Common Terms 3 Assembly Mounting amp Connecting the Sensor 4 7 Assembly Pictorial 4 6 Assembly Getting Started 7 Programming 8 12 Programming Time amp Memory 8 Programming Wind Speed amp Date 9 Programming Rain amp Pressure 10 Programming Weather Forecast amp Indoor Temperature 11 Programming Outdoor Temperature amp Humidity 12 PC Connection 15 EasyWeather PC Software User Manual 14 21 General Information 14 Basic Setup 15 Function Button display and system setup configuration 16 Function Button display and system setup alarm value 16 Function Button display Min and max recorded value 17 Function Button display listed history data 18 Function Button display history in graph mode 19 20 What to do if graph function not working 21 Legal Notes 21 Warranty Back Cover Package Contents Carefully unpack and remove the contents 1 x Display Console 1 x Thermo hygrometerTransmitter with Rain Shield 1 x Wind Direction Sensor 1 x Wind Speed Sensor 1 x Anemometer Mounting Arm 1 x Rain Gauge 2 x Mounting Brackets 1 x Zip Bag fo
2. When base unit is connected to PC the icon of S will be displayed If no base station is connected then will be displayed a at Cramm ee 15 EasyWeather PC Software User Manual Function button display and setup system configuration Sets xi Treme iieys te te Jarpa Pion Tampasta Preise wind Saeed Rana ios far hone the TET 5 io gtr sf Ouddocs T rece Faria Tomase Arrat wrd hd Pear el Aga Ente 7 M Tre F werd Decs Thoen Hemi Loes Treden rm High Ditches Hr ow l ttes Huei High 17 lido Tamgerenne Law D im Tampah M Dudor Tempeaman le T Dita T rene High TT Wik Loe ECET blag l Decors Lew VT Ommen Highs TT Abitase Prtiase Low C Abatte Nes iane Hayy J Fekete Pietine Lim D Filaire Pressure Hoh F Mini Soei He T Gut Some Hen I Hna Rad gh M Cy Feta High r Preteute at This section is used to set up PC software display base station units as well as able or disable the corresponding alarm function Once you made your choice press Save to make the setting effective Function button display and setup system alarm value This section is used to set the desired time high or low alarm value for the base unit Once you made your choice choose Save to make the setting effective If you don t want to make any change just press Cancel and exit without change 16 EasyWeather PC Software User Manual Function button an
3. DATE week date T 2 Touch the DATE section again button and button will be flashing p e Touch the button or button to Shift between DD MM format and MM DD format for the date TOTAL HIAL 3 Touch the DATE section the third time button and button will be RAIN 4 flashing Touch the button or button to set the year Hold the button ri or button for 3s to change the number in great step T u mm 4 Touch the DATE section the fourth time button and button will be e flashing Touch the button or button to set the month Hold the button or button for 3s to change the number in great step 5 Touch the DATE section the fifth time button and button will be flashing Touch the button or button to set the day Hold the button or button for 3s to change the number in great step 6 Touch the DATE section the sixth time button and button will be flashing Touch the button or button to set the alarm hour Hold the button or button for 3s to change the number in great step 7 Touch the DATE section the seventh time button and button will be flashing Touch the button or button to set alarm minute Hold the button or button for 3s to change the number in great step Touch ON OFF to enable or disable time alarm function Programming Rain amp Pressure Rain Activate the rain related setting by 1 Touch the rain section button an
4. button will be flashing WIND N Direct Touch the button or button to Shift the display between Wind Average Speed and Gust Speed NW ey STP p NE 2 Touch the WIND SPEED section again button and button will be Ci ust flashing Touch the button or button to select wind speed unit between km h mph m s knots bft wr J 3 Touch the WIND SPEED section the third time to set the high alarm eo function the ON OFF and button will be flashing HI AL icon will light Ng N up Touch the button or button to change the value hold the button SW ny j W SE or button for 3s to change the number in great step Touch the ON OFF s HI AL button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 4 Touch the Wind SPEED section the fourth time to set wind direction alarm function the wind direction arrow will start to flashing Touch or to select desired alarm for wind direction press ON OFF to enable or disable the wind direction alarm 5 Touch the Wind SPEED section the fifth time to display maximum wind speed record the recorded maximum value will be flashing MAX icon will light up as well Hold the maximum value for 3s the maximum value will be reset to current reading Date 1 Touch the DATE section button and button will be flashing Touch the button or button to shift between alarm time date and
5. display min and max recorded value This section is used to display the recorded min and max value recorded with time stamp Min Max reset can only be done through key operation on the base station EasyWeather PC Software User Manual Function button E display listed history data 4 ESETA en ve he p 5 ZE 0 06 120 p u x zt 07 10 12H e ce Ca 0 y Pate 07 101 v TE E y u ZD 07 10 1299 n ns 55 2 n D 02A 5 73 g amp LWT 07 1012 ut amp Y 4 OP MILK z at 6 Is u ar rn 120 a uy re 4 IENA E e g aa ZY G78 1208 ad uy 55 LA e 2002 07 0 12 V0 r uy u Per A AFA En me en u 47 2 OF 00 12 12 mw 6 x a Pe hs APA L ma amp x LE RIT 12 0 M6 4 1 s Ser 47 9012 hal no 4 ke 3 ar OF PO 1218 u m4 t Le LET A612 6 m no ta x 5 Pe eit BP aD u mt 4 Dv a Po Ste 120 my t 4 A Ei p1 i mat a Q e reo Hi 2 p 7 KWO I n 1a u a ml ka XR 7 ned cn K Q 739 u y Kk ng 5 u mn ond Graeme Sere De jj Ce This section is used to display recorded history data in a spread sheet If you wanted to see all history data in a desired time period choose the time duration and press Search to reload the history data With the Export button you can export the selected history data into text format file for other application purpose When memory on base station is full press Clear Memory button to refresh the memory space on the base station remember to upload
6. 4 M 43 LO AL RH 8 Date 9 Rainfall 10 Weather forecast 11 Indoor humidity 12 Outdoor reception signal 13 Outdoor humidity Glossary of Common Terms LCD LCD is an acronym for Liquid Crystal Display This is a common type of display screen used in televisions computers watches and digital clocks BAROMETER amp BAROMETRIC PRESSURE A barometer is a device that measures the pressure of the air pushing on it this measurement is called the barometric pressure We don t actually feel the barometric pressure because the air pressure is pushing equally in every direction RELATIVE AIR PRESSURE Relative air pressure is the same as the barometric pressure The calculation of relative air pressure is a combination of the absolute air pressure and the altitude ABSOLUTE AIR PRESSURE Absolute air pressure is the actual air pressure on the barometer without regard to altitude INCHES OF MERCURY inHg Inches of Mercury is the common unit of measurement for air pressure in the United States HECTOPASCALS hPa Hectopascals are the common units of measurement for air pressure in the International System Sl of measurement The hectopascal holds the same value Important Note Before inserting batteries please carefully read the operation manual The touch screen weather station includes a base station receiver a transmitter unit one wind direction sensor one wind speed sensor one rain gauge USB cable and a PC
7. F show if outside range 0 1 C 0 2 F 10 99 1 300 1100hPa 8 85 32 5inHg 3hpa under 700 1100hPa 0 1hPa 0 01inHg 120 sec 2XAA 1 5V LR6 Alkaline batteries 2xAA 1 5V LR6 Alkaline batteries Minimum 12 months for base station Minimum 24 months for thermo hygro sensor Remark where outdoor temperature is lower than 20 C make sure proper type of batteries to be used to assure that the device can get enough power to maintain its function properly Normal alkaline batteries is not allow to be used since when outdoor temperature is lower than 20 C the battery s discharging capability is greatly reduced Please help in the preservation of the environment WR and return used batteries to an authorized depot All rights reserved This handbook must not be reproduced in any form even in excerpts or duplicated or processed using electronic mechanical or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their consequences All trademarks and patents are acknowledged Glossary 2 Np nan Time Wind direction Barometric pressure Barometric trend Indoor temperature Outdoor temperature Memory HUMIDITY HIAL 11 Sco NM 12
8. If there is a reset happened for the rain fall on the base station then there will be rain fall value discrepancy between PC and base station Legal Notes e We reserve the right to delete or change any image whether or not purposely uploaded onto the server by a user of the EasyWeather software products The EasyWeather software products are protected by copyright laws and international copyright treaties as well as other intellectual property laws and treaties e You may not copy the printed materials accompanying the products 21 Warranty a aA T Should you have any questions about this product or its operation please telephone our customer service helpline on 1300 716 188 Holman offer a 1 year replacement warranty from the original date of purchase To claim warranty the product must be returned with a copy of the original receipt We will honour all statutory guarantees that this product is of acceptable quality including that it is fit for purpose HOLMAN INDUSTRIES 47 Walters Drive Osborne Park Western Australia 6017 Tel 61 8 9204 1011 Fax 61 8 9204 1013 Web www holmanindustries com au
9. Software User Manual What to do if graph function is not working This is the most encountered problem with this software To make the graph function working properly please check the following step 1 Find the folder where the EasyWeather exe file is located 2 Create a file name reg_graph bat file with wordpad or notepad editor program 3 type regsvr32 easyweather ocx and save the reg_graph bat file 4 Double click reg_graph bat file and it should register the graphic driver again If successful then the following window will be displayed JJ DiRageterSaver in aanp pce puceeeded ae Special Notes about time synchronization between PC and sub station The PC software obtained its own time scale through the time interval marker from the base station history data and the PC software automatically synchronizes the weather data with a time stamp calculated Thus the history data file can have different time when the PC time and base station time is not same In order to make the time scale correct remember to set the PC time and base station time same and further to this no weather data is allowed to be missed or over written If history weather memory on the base station is cleared by manual setting then the history weather data since last uploading is lost permanently Before memory is used up memory icon on LCD display showing 100 full remember to upload weather history data to PC periodically
10. might not be working correctly To run EasyWeather in windows7 Please note that enduser should run the easyweather in windows as administrator 1 Click start icon 2 Find easyweather program and right click mouse 3 Click run as administrator 14 EasyWeather PC Software User Manual 4 0 Basic Settings of the EasyWeather Software After the EasyWeather exe program has been started the following main window will appear on the PG screen 3A E aayWealher Aado Controlled lol x Tapan Sreem Bemad Help L 5 aj lis Sm ali mals Ly a Hpa Sr SA E ae eoi 10 ka L CEEE NE NEET LEEEN Al 2 Pe j laf FA 2 hn n__n HE y 0 Mer o E Fai a Er on A P ns Le J rf mo mE eid oal ee Je e LA SE ola lula we 2 1 27 43 8 repo te Et Y TE ere Y Lo enne T a Max TEN re me iiaa a i LE en i L me mmm mem a All the settings from the base unit is mirrored into the PC software so once you have done your setting on the base unit then you don t need to make any setting changes on the PC software However you can still easily make any setting changes you wanted from the PC and download the changes into the base station the setting change will be refreshed when next full minute arrives on the base station
11. software package on CD ROM The Base Station is equipped with a Touch Screen LCD Monitor and allows the display of a large variety of time and weather data Top line LCD Time and Memory Data Usage Right Middle LCD Date Rain measurement and Weather Forecast Tendency Left Middle LCD Wind Air Pressure and Air Pressure History Bottom Line LCD IN OUT temperature and humidity Note The presence of the Alarm On icon in the section means that the particular alarm has been enabled An added feature of the Weather Station is the readout of all measured and displayed time and weather data onaPC Important Operation Notes All actions and functions of the weather station are started on the touch screen by slightly touching not pressing the related areas touch the flashing ON OFF or to make the corresponding selection or increase the value Every time a programming step is activated by touching a switching area on the Touch Screen a tone will sound and the back light is switched on for a few seconds as well If no areas are pressed for 30 seconds the LCD will automatically revert to the normal display mode automatic time out Assembly Mounting amp Connecting the Sensor ESES aE mt Sse DE a Assembly Mounting amp Connecting the Sensor e The wind gauge s cable is connect to the input on the wind direction sensor e The wind direction sensor s cable is connect
12. the flashing min value for 3s the minimum value will be reset to current reading 11 Programming Outdoor Temp amp Humidity Outdoor Temperature Activate the outdoor temperature related setting by IN TEMP HUMIDITY HA Sc 1 Touch the OUTDOOR TEMPERATURE section Lj 4 button and button will be flashing Touch the RH button or button to Shift the display between OUT TEMP Outdoor Temperature Wind Chill and Dew Point f oc pp 2 Touch the OUTDOOR TEMPERATURE section i i again button and button will be flashing LOAL RAH Touch the button or button to Shift the display unit between C and F 3 Touch the OUTDOOR TEMPERATURE section the third time to set the outdoor temperature high alarm function the ON OFF and button will be flashing HI AL icon will light up Touch the button or button to change the value hold the button or button for 3s to change the number in great step Touch the ON OFF button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 4 Touch the OUTDOOR TEMPERATURE section the fourth time to set the outdoor temperature low alarm function the ON OFF and button will be flashing LO AL icon will light up Touch the button or button to change the value hold the button or button for 3s to change the number in great step Touch the ON OFF button to choose the al
13. all data before pressing this button If you wanted to start a new weather history record press Clear Data button to clear up the data base all history weather data will be deleted if you would like to keep a back up history file before deleting all weather data you can make a copy of the EasyWeather dat file into another folder or just rename the EasyWeather dat file such as Jan 07 dat for future reference 18 EasyWeather PC Software User Manual Function button ea display history data in graph mode In this section you can see the history data plotted in graph format for easier observation If you want to see more details just use your mouse to select the area you wanted and the display will be automatically updated in more detailed scale 19 EasyWeather PC Software User Manual Function button A display history data in graph mode Cont Jol x Gnin riten Settee ora Sint El ntt ror ise mm er rit Vemar vand E BES ESRETRSTRERES ERAS GT DOELD ad 1 2D Sot 1 HO OTE a aon pe Ja vlo age le s en te Ie dr er rm Se Also you can see the graph in 3D mode by selecting the 3D check box EE aigla a fe ior Humid Harap ura i cz Sn MERERERARERERE zr arl heey SAT ATF AH Era ar TT arb En Tr AT oo engen Tina sm he Om te lee WF Ben tem Ce You can change the Y axis by scrolling the mouse roller up and down 20 EasyWeather PC
14. alues can only be read out processed and displayed by means of a PC Also the settings of the storing intervals from 5 minutes to 240 minutes for the storage of data sets can only be performed by means of a PC Connections and Software The wiring between Weather Station and PC takes place by means of an included USB cable The EasyWeather software package also included in the shipping contents must be installed on the PC This software allows the display of all present weather data with graphic symbols It also allows the display storage and printing of history data sets whose volume exceeding the maximum 4080 data sets of the Weather Station is only limited by the capacity of the PC s main memory PC software installation The installation of software is very simple double click the setup exe file and follow the steps popped up Make sure you are running the program under the administrator accounts of your windows PC platform Otherwise the graphic function might not be working when graph display mode is needed to display all history data If you run the program for the first time the current weather display will be displayed and at the sub line of the window the program will show related information regarding the read of all history data into the PC Please note however when there is large amount of data is being uploaded it will take a few minutes time before the system can respond to your setup settings Otherwise it will display
15. arm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 5 Touch the OUTDOOR TEMPERATURE section the fifth time to display maximum outdoor temperature record the recorded maximum value will be flashing MAX icon will light up Hold the flashing max value for 3s the maximum value will be reset to current reading 6 Touch the OUTDOOR TEMPERATURE section the sixth time to display minimum outdoor temperature record the recorded minimum value will be flashing MIN icon will light up as well Hold the minimum value for 3s the minimum value will be reset to current reading Indoor Humidity Activate the indoor humidity related setting by IN TEMP HUMIDITY BH 5 1 Touch the INDOOR HUMIDITY section ot P E again to set the indoor humidity high alarm le R function the ON OFF and button will OUT TEMP a be flashing HI AL icon will light up Touch he c 4 ET ILLL ji the button or button to change the value RH hold the button or button for 3s to change LOAL the number in great step Touch the ON OFF button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 2 Touch the INDOOR HUMIDITY section again to set the indoor humidity low alarm function the ON OFF and button will be flashing LO AL icon will light up Touch the button or button to change the value hold t
16. button OUT TEMP gt or button to Shift the display unit between C and F f f c a Yo 2 Touch the INDOOR f f g f TEMPERATURE section again l LOAL RH to set the indoor temperature high alarm function the ON OFF and button will be flashing HI AL icon will light up Touch the button or button to change the value hold the button or button for 3s to change the number in great step Touch the ON OFF button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 3 Touch the INDOOR TEMPERATURE section the third time to set the indoor temperature low alarm function the ON OFF and button will be flashing LO AL icon will light up Touch the button or button to change the value hold the button or button for 3s to change the number in great step Touch the ON OFF button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 4 Touch the INDOOR TEMPERATURE section the fourth time to display maximum indoor temperature record the maximum records will be flashing MAX icon will light up as well Hold the flashing max value for 3s the maximum value will be reset to current reading 5 Touch the INDOOR TEMPERATURE section the fifth time to display minimum indoor temperature record the minimum records will be flashing MIN icon will light up as well Hold
17. d button will be flashing Touch the button or button to Shift the display between 1h 24h DATE week month and total rain T 2 Touch the rain section again button and button will be flashing Touch the button or button to select rain fall unit between mm inch 3 Touch the rain section the third time to set the high alarm function TOTAL AL the ON OFF and button will be flashing HI AL icon will light up Touch the button or button to change the value hold the button iT or button for 3s to change the number in great step Touch the ON OFF e Lf mm button to choose the alarm on or off if alarm is enabled the speaker icon if will be turned on indicating the alarm function has been enabled 4 Touch the rain section the fourth time to display current maximum rain fall record Touch the rain section for 3s will reset the maximum rain fall value to current value 5 Touch the rain section the fifth time to reset rain fall value to 0 by pressing the rain section for 3s then 1h 24h week month and total rain will be reset to 0 Pressure 1 Touch the PRESSURE section button and button will be flashing PRESSURE rel Touch the button or button to Shift the display between Absolute m Bi H d aj pressure and Relative pressure 2 Touch the PRESSURE section again button and button will be flashing Touch the button or button to Shift the display unit between hPa inHg a
18. ed to the input marked Wind on the thermo hygro sensor see fig 6 Assembly Mounting amp Connecting the Sensor D aren ma p The rain sensor s cable is connected to the input marked Rain on the thermo hygrosensor see fig 7 Assembly Getting Started Important Notes On the edge of wind direction sensor there are four alphabet letter of N E S and W representing for the direction of North East South and West Wind direction sensor has to be adjusted so that the directions on the sensor are matching with your real location Permanent wind direction error will be introduced when the wind direction sensor is not positioned correctly during installation Wind speed sensor wire has to be inserted into the phone jacket on wind direction sensor Wind direction sensor wire has to be inserted into the phone jacket located on the thermo hygro sensor with marking of Wind on top The rain sensor wire has to be inserted into the phone jacket located on the thermo hygro sensor with marking of Rain on top Getting Started You can choose to use the adaptor or batteries for receiver Inserting the batteries Transmitter Outdoor unit Insert 2x alkaline LR6 AA size batteries in the transmitter making sure all the batteries are correctly inserted according to the markings in the battery compartment The indicator on the front of the unit is lit for approximately 4 sec bef
19. he button or button for 3s to change the number in great step Touch the ON OFF button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 3 Touch the INDOOR HUMIDITY section the third time to display maximum indoor humidity record the recorded maximum value will be flashing MAX icon will light up as well Hold the maximum value for 3s the maximum value will be reset to current reading 4 Touch the INDOOR HUMIDITY section the fourth time to display minimum indoor humidity record the recorded minimum value will be flashing MIN icon will light up as well Hold the minimum value for 3s the minimum value will be reset to current reading Outdoor Humidity Procedures and settings are similar to Indoor humidity 12 PC Connection As an important feature in addition to the display on the Touch Screen the Weather Station allows the read out of all measured and displayed time and weather data in form of complete history data sets on a PC Data Storage For a comprehensive weather history the Base Station allows the internal storage of up to 4080 complete sets of weather data with time and date The base station will loose all weather data if an interruption of power supply In case the memory capacity of the Weather Station is exhausted the oldest data sets stored will be overwritten by the new ones entered Data Recall Certain weather data or setting v
20. he maximum value will be reset to current reading 7 Touch the PRESSURE section the seventh time to display minimum pressure record to display minimum pressure record the recorded minimum value will be flashing MIN icon will light up as well Hold the minimum value for 3s the minimum value will be reset to current reading Note when absolute pressure is selected step 3 will be skipped since absolute pressure is selected for display Pressure bar graph Touch the PRESSURE BAR GRAPH section and then press or to toggle the bar 10 graph time scale between 12hrs or 24 hrs for pressure history Programming Weather Forecast amp Indoor Temp Weather forecast 1 Touch the WEATHER FORECAST section button and button TENDENCY will be flashing Touch the button or button to Shift the display i between SUNNY PARTLY CLOUDY and CLOUDY RAINY icon nn 4 2 Touch the WEATHER FORECAST section again button and button will be flashing Touch the button or button to set the pressure threshold from 2 4hPa default 2hPa 3 Touch the WEATHER FORECAST section the third time button and button will be flashing Touch the button or button to set the storm threshold from 3 9hPa default 4 hPa Indoor Temperature Activate the indoor IN TEMP HUMIDITY temperature related setting by 1 Touch the INDOOR H A te So TEMPERATURE section 4 button and button will RH be flashing Touch the
21. ime Zone 7 for Mountain Time zone 8 for Pacific time zone 9 for Alaska time zone 10 for Hawaii time zone 3 Touch the TIME section the third time button and button will be flashing Touch the button or button to Shift the 12 24 hours format 4 Touch the TIME section the fourth time to set the hour the and button will be flashing Touch the button or button to change the value 5 Touch the TIME section the fifth time to set the Minute the and button will be flashing Touch the button or button to change the value Memory 1 Touch Memory section to activate history data toggle display button and button will be flashing Press to toggle forward to see earlier weather history data together time stamp press to see later history weather data When history data displayed the corresponding time will be displayed at the time section area History data saving interval can only be changed using the PC software that comes with this product the default history data saving time interval is preset to 30 minutes prior to shipment 2 Touch Memory section again will trigger the memory clear procedure the word of CLEAR will be flashing the full memory usage icon will be flashing Press and hold the memory full icon for 3 seconds will clear the memory Programming Wind Speed amp Date Wind Speed Activate the wind related setting by 1 Touch the WIND SPEED section button and
22. ld can reach a distance of up to 330 feet providing that there are no interfering obstacles such as buildings trees vehicles high voltage lines etc Radio interferences such as PC screens radios or TV sets can in bad cases entirely cut off radio communication Please take this into consideration when choosing standing or mounting locations Programming Time amp Memory Setting Up Note Because of the default settings already determined by the manufacturer it may not be necessary for the majority of users to perform except the Relative Air Pressure see further down any further basic settings Changes however can be easily made For basic settings the following menu is started by touching the Touch Screen in the desired display area by touch pen The basic settings can now be performed in the following successive order Note setting procedure can be exited at any time by touching any other function area except or ON OFF Time MEMORY 15x Beos 1 Touch the TIME section button and button will be flashing Touch the button or button to adjust the contrast level from 0 to 8 default 5 2 Touch the TIME section again button and button will be flashing Touch the button or button to set the time zone Note In Europe 0 for GMT 1 time zone 1 for GMT 2 time zone 1 for GMT time zone In America 4 for Atlantic time zone 5 for Eastern Time zone 6 for Central T
23. n start to track current and history weather information at your finger tips 2 0 System Requirements To install the EasyWeather software onto your PC the minimum requirements are as follows Operating System Windows NT4 Service Pack gt 6a Windows 2000 Windows XP Windows Vista Windows 7 Internet Explorer 6 0 or above Processor Pentium III 500 MHz or above Memory at least 128MB 256MB recommended CD ROM Drive Base Station and PC must be connected by USB cable 3 0 Installation of the EasyWeather Software Firstly the Base Station and the Outdoor Sensors should be connected and checked for correct function see Operation Manual for WH1080 Touch Screen Weather Station for setting up the Weather Station After successful checking install the EasyWeather software as follows Switch on your PC and insert the CD ROM into the CD ROM Drive Double click Setup exe Select the installation process language option and click next click next and select the destination folder change directory when needed click next and the software will be installed automatically press ok to finish the installation process From Start All Programs EasyWeather path and double click the EasyWeather icon to start application aa ee SS Note The graphic function needs the software to be installed under the administrator account If it is installed under limited user accounts the graphic function of the software
24. nd mmHg Pi HISTORY 3 Touch the PRESSURE section the third time to set the Relative es ta Pressure value The and button will be flashing rel icon will light up en Ss A Sh SE Touch the button or button to change the value hold the button or button for 3s to change the number in great step 12h 10h 8h 6h 4h 2h h Oh 4 Touch the PRESSURE section the forth time to set the pressure high alarm function the ON OFF and button will be flashing HI AL icon will light up Touch the button or button to change the value hold the button or button for 3s to change the number in great step Touch the ON OFF button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 5 Touch the PRESSURE section the fifth time to set the pressure low alarm function the ON OFF and button will be flashing LO AL icon will light up Touch the button or button to change the value hold the button or button for 3s to change the number in great step Touch the ON OFF button to choose the alarm on or off if alarm is enabled the speaker icon will be turned on indicating the alarm function has been enabled 6 Touch the PRESSURE sections the sixth time to display maximum pressure record to display maximum pressure the recorded maximum value will be flashing MAX icon will light up as well Hold the maximum value for 3s t
25. ore it goes out and begins normal functioning again Receiver Indoor unit 1 Open the battery compartment on the unit s back side and insert 2x alkaline LR6 AA batteries Make sure to insert the batteries according to the markings in the battery compartment Replace the battery cover 2 When the batteries have been inserted all icons and symbols will be shortly displayed simultaneously Do not touch the LCD before data has been received from the transmitter otherwise the outdoor sensor learning mode will be terminated right after the touch of LCD This can take a few minutes 3 When data has been received from the transmitter the display will return to normal display mode where all settings can be input NOTE Wait two minutes before re insert the batteries of transmitter for proper reset Setting up using the AC adaptor 1 Power up the transmitter as described in setting up using batteries above 2 Using the AC adaptor plug it into the base station outlet and power up the base station by inserting the adaptor jack into the DC 6 0V socket located on the side of the base station Positioning Once you have verified that all of the components of the weather station are working they can be positioned in their permanent places Before permanently mounting make sure that all components work properly together at their chosen mounting or standing locations Note Commonly the radio communication between receiver and transmitter in the open fie
26. r 6pc Screws 1 x USB Cable 4 x Zip Ties 2 x Poles 1 x EasyWeather CD 2 x Clamps 1 x User Manual General Information Thank you and congratulations on selecting this professional weather station We are positive you will enjoy the benefits of accurate weather readings and the precise radio controlled time information that our instruments offer This manual will guide you step by step through setting up your device Use this manual to become familiar with your professional weather station and save it for future reference NOTE Always remember to use high quality alkaline batteries amp change them at least once per year Specifications Outdoor data Transmission distance in open field Frequency Temperature range Resolution Measuring range rel humidity Rain volume display Resolution Wind speed Measuring interval thermo hygro sensor Water proof level Indoor data Measuring interval pressure temperature Indoor temperature range Resolution Measuring range rel humidity Resolution Measuring range air pressure Accuracy Resolution Alarm duration Power consumption Base station Remote sensor Battery life 100m 300 feet 433MHZ 40 C 65 C 40 F to 149 F 0 1 C 0 2 F 10 99 0 9999mm show if outside range 0 3mm if rain volume lt 1000mm 1mm if rain volume gt 1000mm 0 160km h 0 100mph show if outside range 48 sec IPX3 48 sec 0 C 50 C 32 F to 122
27. read weather data fail error message since the USB port is reading the data from the memory and the system is not able to respond any further job tasks Seber epaeaed beGG cpeses AE LER SRE RSEER SRE RERE isg EL 4 a at r a cre Fra ns cil a MTG H 1E ON STENS ALE ET LE NE TET deh h a di Torgir Mie S am e a C m a i EE oe fee or Nm Cm toca When memory is full it will take about two minutes to upload all history data into PC and it takes another two minutes to process all history data for graphic display Further detailed PC software user manual can be found from the help menu 13 EasyWeather PC Software User Manual 1 0 General Information This Weather Station is a high quality easy to use weather monitoring system that reads displays and records the weather data from internal as well as external sensors Besides the internally measured values for indoor temperature indoor humidity and air pressure the outdoor sensor will take data for temperature and humidity wind and rainfall Operation of these units is by wireless transmission to the Base Station After installing the EasyWeather program on this CD ROM your PC can display all indoor data as well as the weather data from the Base Station received from the external sensors For operation simply use the USB cable supplied and connect the Base Station to the PC From now on you ca