Home
        Ametek mAcal milliAmp Calibrator Datasheet PDF (314
         Contents
1.    play indicates numeric values in mA     V or sec  The resolution is 0 001  mA in measurement mode  The user can change the display to read in    of Full Scale and flow readings are shown in   of Flow     The display also indicates error codes  Visual warnings are displayed for  loop mismatch  reverse polarity and over range  And is also equipped  with a user adjustable automatic shut off feature that prevents accidental  battery discharge when the unit is not in use  A built in  permanent fuse  eliminates the need to replace the fuse in the case of overloads  no need  to return the unit to the factory to reset or replace the fuse     The mAcal provides loop power in the range of 0 to 45 VDC and the  instrument is designed to generate a stable 24 VDC supply for the loop   The mAcal also reduces the time and complexity often associated with  loop calibration  The instrument features special fixed steps for perform   ing linear and flow transmitter or valve positioner calibrations  The instru   ment has seven different built in current values and the user may choose  between manual or automatic steps with 10 or 30 seconds between  steps  You can perform an entire test by placing the mAcal in the pro   cess loop and take readings from the control room     AMETEK    TEST  amp  CALIBRATION INSTRUMENTS    JOFRA        calibration    PWR  Switch between external and  internal loop power supply EXT  Connection Connection  e pened iho ae Connection of   Connection of   test  test le
2.    signal    JOFRA  I     calibration       Sources and measures current  Allows for calibration of transmitters in a two   wire loop       Stable source  Internal 24 VDC supply for consistent  loop power       High resolution  Read to 0 001 mA in the measurement mode         of full scale reading  Displays a percentage to provide for easy  analysis of results       Timesaving features   Fast one key one function access to the  features such as the step function or loop  supply power       Large display   Includes large numbers for unit reading  a  percentage display  and dedicated icons for  calibrator status including a low battery  indicator       Traceable calibration   For your confidence  the unit is supplied with  a calibration certificate that is fully traceable  to a national standards lab such as NIST or  NPL       Complete marine program   Part of a complete program of marine  approved temperature  pressure and signal  calibrators  including temperature sensors    ISO 9001 Manufacturer    Specification Sheet  SS MACAL    millAmp Calibrator  mAcal       The mAcal milliAmp Calibrator is an economical and easy to use calibra   tion device for sourcing and measuring mA signals     The instrument is designed specifically for 2 wire transmitter loops with 4  to 20 mA signals and it is delivered with traceable certification     The keypad is easy to use and provides positive tactile feedback  Each  key is labeled for easy operation  A large  high contrast  5 digit LCD dis
3.   EN50081 1  EN50081 2   E E E EN50082 1  EN50082 2   91 157 EEC   The JOFRA mAcal is type approved by Det Norske Veritas   Find the certificate at www jofra com   Approval  Certificate nO             ccccccccecsseeeseseeeeaeeeeees A 10549    Adjusting the instrument  Connect the mAcal to an external reference instrument as shown in Fig  1     The mAcal now carries out a self calibration and adapts its circuits to that measured   Switch on the mAcal  It is now adjusted and ready for use     Note  The mAcal can only be adjusted in mA  Adjustment of the VDC function is not    Calibrating the instrument  measure mA   Connect the mAcal to an external reference instrument and a current source as shown    Calibration is carried out in the following points  0 mA  4 mA  8 mA  12 mA  16 mA  20  mA and 24 mA  If the mAcal displays EEEEE when measuring the 24 mA  you must  turn down the current until the EEEEE disappears     Calibration must subsequently be carried out at a lower value  e g  23 995 mA      The deviation between the read value of the mAcal and the read value of the reference  instrument must be 8 pA at a maximum     Calibrating the instrument  Source mA   Connect the mAcal to an external reference instrument as shown in Fig  3     Calibration is carried out in the following points  0 mA  4 mA  8 mA  12 mA  16 mA  20  mA and 24 mA  The deviation between the adjusted value of the mAcal and the read  value of the reference instrument must be 8 pA at a maximum        ORDERIN
4.  900 ohm  Temperature coefficient            0 005  per   C   10 to 40  C     A E A 0 003  per   F   14 to 104  F     Current measurement    TEE LAT N A E A E E EE Oto 24 mA  RESOIUUON siavetetecutaeetetsveccansbasaresevaresemucetorutrececcaut 0 001 mA  PCCOUNACY  K 2  asroisssiseins icir  0 05  of F S   Input impedance              cccceececeeeceeeecceeeceeeeeeeeeseneesaes 10 ohm  Temperature coefficient            0 003  per   C   10 to 40  C     A EA 0 002  per   F   14 to 104  F     Voltage measurement    PROG E A E E T O to  45 VDC  RESOLU I stccnescnsicsausetsascescnrtsennesostceseme swede yetasivesseretes 0 1 VDC  PRC CUA a NE 0 5 VDC  Input impedance              cccceeeeceeeceeeeeeeeeseeeeeeeeesaeees 10M ohm    possible        Fig  1    in Fig  2        JOFRAJI     calibration    PHYSICAL SPECIFICATIONS    Power supply    120 VDC Mains Adapters       103964  6 VDC   240 mA US   EEEE AI T  Japan   1 3mm DC female connector  Batteries    a   an  4 Type LR6  AA  1 5 VDC Alkaline  Battery life             c 200 hours with external loop power  PE 20 hours with 12 mA output internal loop power    Instrument weight  incl  batteries  leads and case   aE S a A E E A 0 8 Ibs  355g    Instrument dimensions  incl  batteries  leads and case   Size  L x W x H         6 85 x 2 6 x 1 0 in  174 x 66 x 26 mm    Miscellaneous    Operating  ambient  temperature 14 to 104  F   10 to 40  C   Storage  ambient  temperature       4 to 122  F   20 to 50  C   CE Conformity           89 336 EEC
5. G INFORMATION    75 MACAL  mdAcal Calibrator with standard accesories    STANDARD DELIVERY    e mAcal Calibrator   e mAcal  e Soft carrying case    a i      2 test leads with crocodile clip AMETEK Test  amp  Calibration Instruments    e 4 batteries  type LR6  AA A business unit of AMETEK Measurement  amp  Calibration  Technologies Division offering the following industry  e User manual leading brands for test and calibration instrumentation     JOFRA Calibration Instruments   Temperature Calibrators   Portable dry block calibrators  precision thermometers   and liquid baths  Temperature ranges from   ACCESSORIES  90  C  130  F  to 1205  C 2200  F   Temperature sensors  for industrial and marine use    Pressure Calibrators    103964 Mains adapter for mAcal   US   Japan a clade ere eee ranging Haia sled to    ar   Tully temperature compensated tor propiem    103950 Mains adapter for mAcal   Europe  free and accurate field use   103957 Mains adapter for mAcal   UK Signal Instruments  124716 4x 1 5 Volt rechargeable batteries Process signal measurement and simulation for on  124718 Charger for rechargeable batteries   115 230 VAC g e ee ee ae ena     M amp G Pressure Testers  amp  Pumps   Pneumatic floating ball or hydraulic piston dead weight  testers with accuracies to 0 015  of reading  Pressure  generators delivering up to 1 000 bar     Lloyd Instruments   Materials testing machines and software from Lloyd  Instruments guarantees expert materials testing  solutions  The compr
6. ad lead Display    power supply  and INT   the  24  VDC of the current loop is gen   erated by the mAcal itself      Mains adapter    Connection to mains adapter   6 VDC  230 mA     Note   The mains adapter does  not charge rechargeable bat   teries     ON OFF  Switching instrument on off     Auto shut off to extend battery  life  user programmable      mA     setup    Alternating between readout in  mA and    If the key is held  down for more than 2 sec   a  change to SETUP takes place   Under SETUP this key is used  to select next parameter     Auto    AUTO ramp or AUTO STEP  function is started or stopped           Shows numerical value in  mA     V or sec   and for  readout of error codes etc     FUNC    This key allows for changing  functions between SOURCE  mA  MEASURE mA and  MEASURE Volt function     Step    The STEP function is acti   vated or de activated     Up arrow    Functions to increase  entered values or to scroll    up     Down arrow    Functions to decrease  entered values or to scroll  down     JOFRA mAcal in softcase   The mAcal calibrator is available separately and are supplied in a handy softcase that  allows for complete operation of the unit while in the case  The convenient internal  arrangement offers you the space to store test leads           FUNCTIONAL SPECIFICATIONS    Current source    BELS LEE NE E A N EEE E Oto 24 mA  RESOUN renanira ei NAER 0 01 mA  ACCURACY  K 2  iacacctcntnctaacnccesceaverarcesnteeien  0 05  of F S   Maximum load eisernen
7. ehensive program also covers  Texture Analysers to perform rapid  general food testing  and detailed texture analysis on a diverse range of foods  and cosmetics     Davenport Polymer Test Equipment  Allows measurement and characterization of moisture   sensitive PET polymers and polymer density     Chatillon Force Measurement   The hand held force gauges and motorized testers  have earned their reputation for quality  reliability and  accuracy and they represent the de facto standard for  force measurement     Newage Testing Instruments  Hardness testers  durometers  optical systems and  software for data acquisition and analysis           AMETEK www jofra com    TEST  amp  CALIBRATION INSTRUMENTS    AMETEK Mansfield  amp  Green  North America   T   1 800 527 9999   cal info ametek com    AMETEK Singapore Pte  Ltd   Singapore   T   65 6 484 2388   aspl ametek com sg    AMETEK Denmark A S AMETEK Inc  Beijing Rep  Office  China   Gydevang 32 34   3450 Aller  d   Denmark T   86 10 8526 2111   jofra ametek com cn  T   45 4816 8000   ametek ametek dk AMETEK Instruments India Pvt Ltd   India     T   91 22 2836 4750   ametek ametek dk    AMETEK GmbH  Germany   T   49 2159 9136 510   info mct de ametek de    AMETEK Calibration Instruments  UK   Information in this document is subject to change without notice    2012  by AMETEK  Inc   www ametek com  All rights reserved  T   44  0  1243 833 302   jofra ametek co uk    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Manual de instrucciones REPRODUCTOR  China  Milescraft 13100713 Use and Care Manual    MPC564EVB User`s Manual - Hitex Development Tools  Colony Counting  Tocar o meu filho: Experiência de mães com filhos internados numa  Configuring and Troubleshooting Windows  第30期 2010年3月期 第2四半期決算説明会    Copyright © All rights reserved. 