1. Thank you for purchasing this Esco Laboratory Fume Hood Please read this manual thoroughly to familiarize yourself with the many unique features and exciting innovations we have built into your new equipment Esco provides many other resources at our website www escoglobal com to complement this manual and help you enjoy many years of productive and safe use of your Esco products For Technical Service contact North America Esco Technologies Inc 2940 Turnpike Drive Units 15 16 Hatboro PA 19040 USA Toll Free USA and Canada 1 877 479 3726 Tel 215 441 9661 Fax 215 441 9660 us escoglobal com usa escoglobal com Rest of World Esco Micro Pte Ltd 21 Changi South Street 1 Singapore 486 777 Tel 65 6542 0833 Fax 65 6542 6920 www escoglobal com mail escoglobal com Esco Laboratory Fume Hood EFB EFH EFD EFU User Manual Version A Released May 2011 User Manual Frontier Laboratory Fume Hood Copyright Information Copyright 2011 Esco Micro Pte Ltd All rights reserved The information contained in this manual and the accompanying product is copyrighted and all rights are reserved by Esco Esco reserves the right to make periodic minor design changes without obligation to notify any person or entity of such change Frontier and Sentinel are registered trademarks of Esco Material in this manual is provided for informational purposes only The contents and the product described in this manu
2. Should the unit malfunction stop the operation and then pull out the power plug or turn off the power supply at source Continuing to operate the unit when it shows signs of malfunctioning may cause electric shocks or fire The following troubleshooting are some of the basic problems that can be solved by the user or operator However if the problem persist please contact your local distributor Problem Possible Cause so Ensure that the exhaust blower fan set correctly for this function request your distributor to re certify the system and re set the exhaust blower fan The hoods lamp does not work work PE PRINT The hood show poor performance Laboratory Fume Hood ECO ECCO Frontier APPENDIX LOG RECORD Fume Hood Serial Number Person in Charge 1 This log record should be used by the operator to record any new chemicals that has been introduced to the fume hood during its operation problems encountered etc 2 Please also record any major maintenance procedure performed by the service technician for example parts replacement recertification etc User Signature Supervisor Signature In case of emergencies please call Name Cell Phone Number E mail
3. Frontier Duo Model EFD 4A1 EFD 4B1 EFD 5A1 EFD 5B1 EFD 6A1 EFD 6B1 in accordance with the following directives 2006 95 EEC The Low Voltage Directive and its amending directives 92 31 EEC The Electromagnetic Compatibility Directive and its amending directives has been designed to comply with the requirement of the following Harmonized Standard Low Voltage EN 61010 1 2010 EMC EN 61326 1 2006 Class B Design ANSI ASHRAE 110 1995 Performance European Union Standard EN 14175 3 Criteria More information may be obtained from Esco s authorized distributors located within the European Union A list of these parties and their contact information is available on request from Esco XQ Lin Group CEO Esco This Declaration of Conformity is only applicable for 220 240V AC 50Hz units Laboratory Fume Hood ECO Declaration of Conformation In accordance to EN ISO IEC 17050 1 2010 We Esco Micro Pte Ltd of 21 Changi South Street 1 Singapore 486777 Tel 65 6542 0833 Fax 65 6542 6920 declare on our sole responsibility that the product Category Laboratory Fume Hood Brand Frontier Edusafe Model EFU 4A1 EFU 5A1 EFU 6A1 in accordance with the following directives 2006 95 EEC The Low Voltage Directive and its amending directives 92 31 EEC The Electromagnetic Compatibility Directive and its amending directives has been designed to comply with the requirement of the following Harmonized Stand
4. Conditions Esco products come with either a 1 2 or 3 year limited warranty depending on the product purchased beginning on the date of shipment from any Esco international warehousing location To determine which warranty applies to your product refer to the appendix below Esco s limited warranty covers defects in materials and workmanship Esco s liability under this limited warranty shall be at our option to repair or replace any defective parts ofthe equipment provided if proven to the satisfaction of Esco that these parts were defective at the time of being sold and that all defective parts shall be returned properly identified with a Return Authorization This limited warranty covers parts only and not transportation insurance charges This limited warranty does not cover e Freight or installation inside delivery handling damage If your product was damaged in transit you must file a claim directly with the freight carrier e Products with missing or defaced serial numbers e Products for which Esco has not received payment e Problems that result from o External causes such as accident abuse misuse problems with electrical power improper operating environmental conditions Servicing not authorized by Esco Usage that is not in accordance with product instructions Failure to follow the product instructions Failure to perform preventive maintenance Problems caused by using accessories parts or components not supplied b
5. ENU Admin PIN has higher priority and can be used to control the fan override Fan PIN The default PIN is 0009 Setting PIN to 0000 will disable this feature MENU ADMIN NEW ADMIN PIN XXXX Laboratory Fume Hood ECO 3 2 3 2 New Fan PIN When the exhaust blower in the ducting system is connected to the fume hood the Fan PIN restricts access to fan control User must enter four digit PIN before switching fan on or off As such it can restrict access to operating the fume hood by unauthorized personnel It will also prevent unauthorized shutdown of the fume hood when continuous operation is required Fan PIN is also needed to disable the alarm when the sash is fully raised and cleaning needs to be performed It is recommended that the Fan PIN be issued only to personnel authorized to use the fume hood The default PIN is 0001 Setting the PIN to 0000 will disable this feature MENU ADMIN NEW FAN PIN XXXX 3 2 3 3 A F Monitor Whenever the air velocity falls below the fail point the air fail alarm will be triggered This option is used to enable disable alarm The default value for A F monitor is enabled MENU ADMIN A F MONITOR DISABLE ENABLE 3 2 3 4 Reset Blower Hour Meter This option is used to reset the blower hour meter The blower hour meter indicates how long the
6. MEDIES PROVIDED FOR IN THIS LIMITED WARRANTY OR FOR SPECIAL INDIRECT CONSEQUENTIAL OR INCIDENTAL DAMAGES INCLUDING WITHOUT LIMITATION ANY LIABILITY FOR THIRD PARTY CLAIMS AGAINST YOU FOR DAMAGES FOR PRODUCTS NOT BEING AVAILABLE FOR USE OR FOR LOST WORK ESCO S LIABILITY WILL BE NO MORE THAN THE AMOUNT YOU PAID FOR THE PRODUCT THAT IS THE SUBJECT OF A CLAIM THIS IS THE MAXIMUM AMOUNT FOR WHICH ESCO IS RESPONSIBLE Laboratory Fume Hood Ecco These Terms and Conditions shall be governed by and construed in accordance with the laws of Singapore and shall be subject to the exclusive jurisdiction of the courts of Singapore Technical Support Warranty Service Contacts USA 1 877 479 3726 Singapore 65 65420833 Global Email Helpdesk support escoglobal com Visit http www escoglobal com to talk to a Live Support Representative Distributors are encouraged to visit the Distributor Intranet for self help materials Product Appendix Warranty Listings Biological Safety Cabinets Laminar Flow Cabinets your local distributor for specific warranty details The warranty period starts two months from the date your equipment is shipped from Esco facility for international distributors This allows shipping time so the warranty will go into effect at approximately the same time the equipment is delivered to the user The warranty protection extends to any subsequent owner during the warranty period Distributors who stock Esco equipment are allow
7. al including any appendix addendum attachment or inclusion are subject to change without notice Esco makes no representations or warranties as to the accuracy of the information contained in this manual In no event shall Esco be held liable for any damages direct or consequential arising out of or related to the use of this manual a Table of Contents INTRODUCTORY PAGES i Table of Contents iii Warranty Terms and Conditions Introduction 1 Products Covered 2 Safety Warning 3 Limitation of Liability vi 4 European Union Directives on WEEE and RoHS vii EFB Declaration of Conformation viii EFH Declaration of Conformation lt lt X EFD Declaration of Conformation X EFU Declaration of Conformation USER SECTION 1 1 1 About Frontier Acela Series Fume Hoods 1 1 2 Labels 2 1 3 Quick View 2 1 3 1 EFB Series Quick View 3 1 3 2 EFH Series Quick View 4 1 3 3 EFD Series Quick View 5 1 3 4 EFU Series Quick View 7 Chapter 2 Control System and Operation 7 2 1 Basic ON OFF Control 7 2 2 General Fume Hood Operation Chapter 3 EFD B Series Sentinel Control System 9 3 1 Sentinel Control System 10 3 2 Menu Options 10 3 2 1 Settings 11 3 2 2 Calibration 11 3 2 3 Admin 12 3 2 4 Settingthe Mode 13 Chapter 4 Service and Maintenance 13 4 1 Scheduled Maintenance 14 4 2 Maintenance Service Log 15 Chapter 5 Troubleshooting APPENDIX Laboratory Fume Hood ECO ESCO j Frontier Warranty Terms and
8. al outlet Airfoil Base cabinet side filler panel ee ee ee a ee HR UNEO ESEO Frontier 1 3 4 EFU Series DO OO 22 E Exhaust collar Sash counterbalance roller base Fluorescent lamp housing Removable glass baffle Fixed internal glass Fixture outlet nozzle Design opening sash lock handle Fixture valve remote control Fixture internal access panel Polypropylene water drip cup sink General purpose base cabinet Adjustable base cabinet shelf Electrical panel Side view glass Front sash glass Operating switches Electrical outlet Fixture valve remote control provision ne ae PP Ip PRP RPP rPrP PPP CON DU BWNPF Laboratory Fume Hood ECO ECCO Frontier Chapter 2 Control System and Operation 2 1 Basic On Off Control ESCO FRONTIER LABORATORY FUME HOOD ANSI ASHRAE 110 1995 Contaiment Tested BS7258 EN14175 3 Work into the chamber and keep the sash as low as possible Overloading the work zone with items can disrupt the airflow Observe the chemical limits approved by laboratory supervisor Close front sash when not in use for maximum safety This unit must be tested certified annually x ne Z Ar Zx 21 Changi South Street 1 Singapore 486 777 Tel 65 6542 0833 Fax 65 6542 6920 Email fum
9. ard Low Voltage EN 61010 1 2010 EMC EN 61326 1 2006 Class B Design ANSI ASHRAE 110 1995 Performance European Union Standard EN 14175 3 Criteria More information may be obtained from Esco s authorized distributors located within the European Union A list of these parties and their contact information is available on request from Esco XQ Lin Group CEO Esco This Declaration of Conformity is only applicable for 220 240V AC 50Hz units ECCO I Frontier Chapter 1 Product Information 1 1 About Frontier Series Fume Hoods The Esco Frontier Series Fume Hood offers a solution representing design and engineering innovations that are at the forefront of fume hood technology providing superior containment of noxious chemical fumes at a broad range of face velocities while addressing worker comfort through ergonomic design Work zone baffles and aerodynamic airfoil are designed with computational fluid dynamics to enhance safety 1 2 Labels CABINET POWER INLET 220 240VAC 50Hz 6A single phase Damage may result ifthe cabinet is connected to an incorrect power source Cabinet power requirement ECCO Model EFD 4B1 Serial 2009 41660 21 Changi South Street 1 Singapore 486777 Power 100W 220 240VAC 50HZ 1PH Tel 65 6542 0833 Fax 65 6542 6920 mail escoglobal com Manufactured in August 2009 www e al com Model The model of the unit Serial The serial number of the unit Power The po
10. blower has been in operation The counter value can be checked while in maintenance mode The value can also provide some help in setting up maintenance schedule including filter change MENU ADMIN RESET B H M 3 2 3 5 Reset Default User can reset the default setting by choosing this option The features being reset are warm up period 3 minutes post purge period 0 minute UV timer 60 minute airflow unit Metric temperature unit Celsius Admin PIN 0009 Fan PIN 0001 and A F Monitor enabled Note that the calibration settings cannot be reset as it may cause the BSC to operate in an unsafe manner The hour meters cannot be reset either MENU ADMIN RESET DEFAULT 3 2 4 Setting the Mode Fume Hood has two working mode the default normal mode which is used in a day to day activity and maintenance mode NORMAL MENU SET MODE MAINTENANCE 3 2 4 1 Normal Mode Every time the hood is restarted this mode will be activated by default In this mode all alarms and interlocks are enabled 3 2 4 2 Maintenance Mode Maintenance mode should only be accessed by qualified personnel during maintenance In this mode all alarms are disabled and all interlocks are defeated ECCO IFrontier Chapter 4 Service and Maintenance 4 1 Scheduled Maintenance Proper and timely maintenance is
11. cleaner e For removing stubborn stains or spots on the stainless steel surface make use of MEK Methyl Ethyl Ketone In such cases make sure that you wash the steel surface immediately afterwards with clean water and some liquid detergent Use a polyurethane cloth or sponge for washing Regularly cleaning the stainless steel surface can help you retain the attractive factory finish e Ensure that there s no blockage in and behind the baffle Check the hood s functionality e Check the hood s mechanical functionality ex sash window lubricate if necessary e Check the hood s electrical functionality ex fluorescent lamp replace if necessary e Check the hood for any defect repair immediately e Check the hood s airflow pattern and face velocity to ensure that the hood is functioning properly Re certification All fume hoods must be re certified annually by a certified engineer See test report for recertification procedure Check and clean the ducting system Laboratory Fume Hood ECO 4 2 Maintenance Service Log It is good practice and in some cases regulatory requirement to maintain a log of all maintenance work carried out on your cabinet ECCO Frontier Chapter 5 Troubleshooting Under no circumstances should the unit be disassembled repaired or converted by unqualified people Failure to follow these instructions may cause personnel injury and or loss of property due to malfunctions electric shocks or fire
12. crucial for trouble free functioning of any device and your Esco fume hood is no exception to this rule We strongly recommend that you follow the maintenance schedule suggested hereunder in order to obtain optimal performance from your Esco fume hood Maintenance to be carried out every Month Quarter 1 Clean the interior work surface and was Lv S S 2 Clean the sash and all glass surfages vu S S 3 Airflow patterns check using a source ofvisiblesmoke Tyo 4 Inspect the controls of the services to the fume Rod I S 5 Clean the exterior surfaces ofthefumehood I u I e ET ee 7 Determine the face velocity and ensure that the hood is operating properly v I 8 Inspect the fume hood for any physical abnormalities or malfunction v 9 Checkthesashforproperoperation o Sw e 10 Change thefluorescentlamps S S o 11 Recertification ooo d S S o 12 Check amp clean the ducting system ET S S No z Description of Task to Perform Cleaning the fume hood e Clean the work surface and walls with appropriate disinfectant agent and soap water afterward e Clean the sash window using an appropriate disinfectant agent and glass cleaner afterward e Usea damp cloth to clean the exterior surface of the fume hood particularly on the front and top in order to remove dust that accumulated there e Use clean water to finish the cleaning and wash away any residue of disinfectant agent soapy water and glass
13. e a value in a menu display Laboratory Fume Hood ECO 3 2 Menu Options Please refer to the following diagram for complete reference to all menu options available Press UP or DOWN to scroll through the menu options The user is strongly advised to exit from the menu options after making any changes in order to prevent unauthorized access to the menu SET TIME HH MM WARM UP 3 lt XX lt s15 SETTINGS VELOCITY UNIT FPM M S TEMP UNIT CELCIUS FAHRENHEIT SET CONSTANT CALIBRATION ZERO SENSOR CALIB SENSOR MENU NEW ADMIN PIN XXXX NEW FAN PIN XXXX ADMIN A F MONITOR DISABLE ENABLE RESET B H M RESET DEFAULT NORMAL SET MODE an MAINTENANCE 3 2 1 Settings The user may use the settings menu function to customize the operation of the fume hood to meet specific application requirements 3 2 1 1 Set Clock Time Users can set the time by increasing decreasing the hour and minute values The correct time will be maintained even after the unit is turned off MENU SETTINGS SET TIME HH MM 3 2 1 2 Warm Up Timer There will be a period of warm up before the fan is fully functioning This is to ensure that the sensors the fan and the control
14. ed an additional four months for delivery and installation providing the product is registered with Esco User can register product online at www escoglobal com warranty or complete the warranty registration form included with each product Policy updated on 19 Apr 2011 This limited warranty policy does not apply to products purchased before 12 Apr 2011 ESCO j Frontier Introduction 1 Products Covered Esco High Performance Laboratory Fume Hood Frontier Acela Family 1 2 meters 1 5 meters 1 8 meters 2 4 meters 4 feet 5 feet 6 feet 8 feet 220 240 V AC 50 Hz 10 EFB 4A1 EFB 6A1 Model Electrical Rating ren Junior 120 v AC 60Hz 10 EFB AA2 EFB 6A2 EFB 220 240 V AC 50 Hz 10 EFB 4A3 EFB 6A3 Frontier Mono 220 240 V AC 50 Hz 10 EFH 4A1 oy 110 120 VAC 60H EFH EFH6A2 an 220 240 VAC 50Hz O EFH 443 EFH 6A3 EFD 4A1 EFD 5A1 EFD 6A1 EFD 8A1 RE ONF EFD 4B1 EFD 5B1 EFD 6B1 EFD 8B1 Frontier Duo EFD 4A2 EFD 5A2 EFD 6A2 EFD 8A2 EFD o LONAC SONi EFD 4B2 EFD 5B2 EFD 6B2 EFD 8B2 EFD 4A3 EFD 5A3 EFD 6A3 EFD 8A3 SE E EFD 4B3 EFD 5B3 EFD 6B3 EFD 8B3 220 240 V AC 50 Hz 1 ue CSET NINA EFU 4A2 EFU 5A2 EFU 6A2 Edusafe EFU 330 240 V AC 50 Hz 10 Note MCB is not included with the fume hood 2 Safety Warning e Anyone working with on or around this equipment should read this manual Failure to read understand and follow the instructions given in this documentation may result in damage to the un
15. ehoods escoglobal com Website fumehoods escoglobal com 150 9001 Certified Manufacturer Lamp Switch Fan Switch 1 Fan Switch o Turns the external exhaust blower on and off if connected 2 Lamp Switch o Turns the fluorescent lamps on and off 2 2 General Fume Hood Operation e Follow your laboratory procedure on the use of personnel protective equipment and fume hood e Ensure the exhaust is operating before commencing work e Keep your head outside of the hood e Work as far into the hood as possible and with slow deliberate movements to minimize airflow disturbances e Work with the sash as fully lowered as possible utilizing the sash as a natural barrier to accidents which may occur in the hood e fa combination sash is installed do not open the vertical and horizontal sashes simultaneously e Do not use this hood as a storage area Items can block airflow and interfere with containment e Do not let organic chemicals evaporate in the hood use a proper waste bottle Do not leave uncapped bottles of chemicals or waste in a hood e If performance is suspected or an airflow alarm is triggered if installed terminate usage close the sash completely and cease work e Do not use perchloric acid in a fume hood unless it is specially designed for this purpose Explosive perchlorate salts could accumulate in the exhaust system e Minimize external airflow disturbances including foot traffic e Certify this hood annua
16. f overview of the calibration menu function SET CONSTANT MENU CALIBRATION ZERO SENSOR CALIB SENSOR 3 2 2 1 Set Constant Every sensor manufactured by Esco has a specific Sensor Constant which is used for temperature compensation performed by the temperature sensor 3 2 2 2 Zero Sensor This option is to let the controller record the specific sensor output voltage and correspond it to 0 m s or O fpm 3 2 2 3 Calib Sensor This option allows proper calibration and operation of the airflow sensor alarm There will be three points to be calibrated namely fail point and optimum point Fail point is a point in which the face velocity of the fume hood deemed can no longer maintain containment Optimum point is a point in which the face velocity of the fume hood deemed able to optimally protect the operator 3 2 3 Admin The admin menu allows you to change both fan and Admin PIN also to disable it not recommended The reset blower hour meter and reset UV hour meter functions are usually used after you change the blower or UV lamp as they can easily give you the indication on when to do fume hood maintenance While the reset default function will return the options in the settings menu to their factory settings 3 2 3 1 New ADMIN PIN Admin PIN restricts access to MENU functions including service functions like calibration User must enter four digits PIN before accessing M
17. is only applicable for 220 240V AC 50Hz units Laboratory Fume Hood ECO viii Declaration of Conformation In accordance to EN ISO IEC 17050 1 2010 We Esco Micro Pte Ltd of 21 Changi South Street 1 Singapore 486777 Tel 65 6542 0833 Fax 65 6542 6920 declare on our sole responsibility that the product Category Laboratory Fume Hood Brand Frontier Mono Model EFH 4A1 EFH 5A1 EFH 6A1 in accordance with the following directives 2006 95 EEC The Low Voltage Directive and its amending directives 92 31 EEC The Electromagnetic Compatibility Directive and its amending directives has been designed to comply with the requirement of the following Harmonized Standard Low Voltage EN 61010 1 2010 EMC EN 61326 1 2006 Class B Design ANSI ASHRAE 110 1995 Performance European Union Standard EN 14175 3 Criteria More information may be obtained from Esco s authorized distributors located within the European Union A list of these parties and their contact information is available on request from Esco XQ Lin Group CEO Esco This Declaration of Conformity is only applicable for 220 240V AC 50Hz units ECCO I Frontier Declaration of Conformation In accordance to EN ISO IEC 17050 1 2010 We Esco Micro Pte Ltd of 21 Changi South Street 1 Singapore 486777 Tel 65 6542 0833 Fax 65 6542 6920 declare on our sole responsibility that the product Category Laboratory Fume Hood Brand
18. it injury to operating personnel and or poor equipment performance e Any internal adjustment modification or maintenance to this equipment must be undertaken by qualified service personnel e The use of any hazardous materials in this equipment must be monitored by an industrial hygienist safety officer or some other suitably qualified individual e Before you process you should thoroughly understand the installation procedures and take note of the environmental electrical requirements e Inthis manual important safety related points will be marked with the symbol A e lf the equipment is used in a manner not specified by this manual the protection provided by this equipment may be impaired 3 Limitation of Liability The disposal and or emission of substances used in connection with this equipment may be governed by various local regulations Familiarization and compliance with any such regulations are the sole responsibility of the users Esco s liability is limited with respect to user compliance with such regulations Laboratory Fume Hood ECO 4 European Union Directive on WEEE and RoHS The European Union has issued two directives e Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE This product is required to comply with the European Union s Waste Electrical amp Electronic Equipment WEEE Directive 2002 96 EC It is marked with the following symbol Esco sells products through distrib
19. lly to verify airflow velocity smoke patterns and containment e Perform routine maintenance in accordance with the manufacturer s instructions e In case of spills please refer to the laboratory procedure Laboratory Fume Hood ECO ECCO Frontier mE Chapter 3 EFD B Series Sentinel Control System 3 1Sentinel Control System MENU SET UP DOWN LCD button button button button Display Read all safety related instructions before use Test certify this cabinet at least annually Designed to Meet IEC 61010 1 Safety Protection Standards ISO 9001 Quality Certified Manufacturing Environment a FAN LIGHT SOCKET UV button button button button e FAN button o To turn on off the exhaust blower fan if connected to the exhaust blower fan system e LIGHT button o To turn on off the light e SOCKET button o To turn on off the electrical outlets e UV button o Unused e MENU button When you are entering menu options the alarm will sound to indicate that the microprocessor is not monitoring the operation of the cabinet No further warnings will be given o Toenter exit the menu display o To cancel a selection in a menu display e SET button o To choose confirm a selection in a menu display e UP and DOWN buttons o To move the sash window up or down only in a motorized sash hood o To start stop and reset timer only in a non motorized sash hood o To move up or down in a menu display o To increase or decreas
20. system are stabilized as well as purging the work zone of contaminants The default setting is 3 minutes and user can set it up to 15 minutes When airflow alarm is disabled the warm up process only takes place during the installation MENU SETTINGS WARM UP 3 lt XX lt 15 ECCO Frontier 3 2 1 3 Airflow Unit Selection Using this option you can select the unit in which air velocity is measured and displayed You can choose between meter per second m s and feet per minute fpm When the fan is running and also during the calibration process airflow measurement is displayed in the selected unit MENU SETTINGS VELOCITY UNIT FPM M S 3 2 1 4 Temperature Unit Selection Using this option you can select the unit in which temperature is measured and displayed You can choose between Celsius and Fahrenheit The exhaust temperature is displayed in the selected unit MENU SETTINGS TEMP UNIT CELCIUS FAHRENHEIT 3 2 2 Calibration The purpose of calibration is to ensure the accuracy of the airflow display and alarm if present This involves measuring airflow with reference instrumentation and establishing reference between airflow sensor s on the fume hood to the standard reference Calibration should only be carried out by trained personnel This section is presents a brie
21. utors throughout Europe Contact your local Esco distributor for recycling disposal e Directive 2002 95 EC on Restriction on the use of Hazardous Substances RoHS With respect to the directive on RoHS please note that this hood falls under category 8 medical devices and category 9 monitoring and control instruments and is therefore exempted from requirement to comply with the provisions of this directive ESCO Frontier Declaration of Conformation In accordance to EN ISO IEC 17050 1 2010 We Esco Micro Pte Ltd of 21 Changi South Street 1 Singapore 486777 Tel 65 6542 0833 Fax 65 6542 6920 declare on our sole responsibility that the product Category Laboratory Fume Hood Brand Frontier Junior Model EFB 4A1 EFB 5A1 EFB 6A1 in accordance with the following directives 2006 95 EEC The Low Voltage Directive and its amending directives 92 31 EEC The Electromagnetic Compatibility Directive and its amending directives has been designed to comply with the requirement of the following Harmonized Standard Low Voltage EN 61010 1 2010 EMC EN 61326 1 2006 Class B Design ANSI ASHRAE 110 1995 Performance European Union Standard EN 14175 3 Criteria More information may be obtained from Esco s authorized distributors located within the European Union A list of these parties and their contact information is available on request from Esco XQ Lin Group CEO Esco This Declaration of Conformity
22. wer consumption and electrical requirement of the unit Manufactured year The year of manufacture Laboratory Fume Hood ECO 1 3 Quick View 1 3 1 EFB Series Counter Balanced Sash Removable Front Panel Exhaust Collar Electrical Panel Fluorescent Lamp Baffle Service Fixture Outlet Blower Light Switch 9 Ergonomic Airfoil 10 Service Fixture Remote Control 11 Electrical Outlets oO OR EE S e ECCO Frontier 1 3 2 EFH Series eae eS RE PRP PrP PRP DnuUBBWNHR Exhaust collar Sash counterbalance roller base Fluorescent lamp housing Phenolic baffle Fixture outlet nozzle Polypropylene water drip cup sink Fixture valve remote control Adjustable base hood shelf General purpose base hood Electrical panel Front panel with bypass louver Operating switches Front sash glass Phenolic worktop Electrical outlet Base cabinet side filler panel amp O N Laboratory Fume Hood ECO s 1 3 3 EFD Series 6 7 8 1 9 ey T7110 3 11 ae 12 5 13 14 Sash window Service fixture outlet Service fixture remote controls Phenolic Resin work top Optional base cabinetry for additional storage area in the laboratory Exhaust collar Electrical panel Fluorescent lamp Removable front panel Sentinel Controller only for EFD B_ model Optional airflow sensor only for EFD B_ model Electric
23. y Esco Damage by fire floods or acts of God o Customer modifications to the product e Consumables such as filters HEPA ULPA carbon pre filters and fluorescent UV bulbs e Esco is not liable for any damage incurred on the objects used on or stored in Esco equipment If the objects are highly valuable user is advised to have in place independent external preventive measures such as connection to a centralized alarm system O O O OD Factory installed customer specified equipment or accessories are warranted only to the extent guaranteed by the original manufacturer The customer agrees that in relation to these products purchased through Esco our limited warranty shall not apply and the original manufacturer s warranty shall be the sole warranty in respect of these products The customer shall utilize that warranty for the support of such products and in any event not look to Esco for such warranty support Esco encourages all users to register their equipment online at www escoglobal com warranty or complete the warranty registration form included with each product ALL EXPRESS AND IMPLIED WARRANTIES FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES AND CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN TIME TO THE TERM OF THIS LIMITED WARRANTY NO WARRANTIES WHETHER EXPRESS OR IMPLIED WILL APPLY AFTER THE LIMITED WARRANTY PERIOD HAS EXPIRED ESCO DOES NOT ACCEPT LIABILITY BEYOND THE RE