Contents

1. Include Sensor 2 in Sum with other sensors S individually I or not included blank Include Sensor 3 in Sum with other sensors S individually I or not included blank SEn 4H Sor Include Sensor 4 in Sum with other sensors S individually P or not included blank durfen Active trigger Duration interval seconds or continuous contin Setting the duration to 0 causes the DS 3000 to be in continuous mode output is active whenever the threshold conditions are satisfied Summary Contact output 1 can be used to control external equipment attached by means of the provided removable wiring connector Contact terminals are marked COM common NO normally open and NC normally closed The contact terminal labels indicate the inactive contact state le NO contacts are OPEN when inactive but CLOSED when active Both NO or NC contacts are referenced to the COM or common terminal Outputs may be pulsed by selection of appropriate momentary contact duration or continuous More details and examples programming these entries will be given in the programming examples section following later in this document 8 2 5 Relay Output 2 Menu Function Setup output contact 2 related parameters Keystrokes Press menu till ELAY 2 is displayed then press up or down to select which parameter you d like to adjust then press enter to edit each entry
2. 48089 Fremont Blvd Fremont CA 94538 Loads m 510 623 9600 AH tar www loadstarsensors com S E N S O R S DS 3000U Digital Display Module 4 channel USB Sensor Input Users Guide Copyright 2008 2010 Loadstar Sensors Inc All rights reserved DS 3000U DS3000 User Guide Notes Copyright 2008 2010 Loadstarsensors Inc All Rights Reserved No part of this manual may be reproduced in any form or by any means including electronic storage and retrieval or translation into a foreign language without prior agreement and written consent from Loadstar sensors Inc as governed by United States and international copyright laws Manual Part Number 033 01419 First Edition Released June 2008 Second Edition Nov 2008 Third Edition Dec 2009 for F W Revision 3 04 Fourth Edition Jan 2010 for F W Revision 3 05 Loadstar Sensors Inc 48089 Fremont Blvd Fremont CA 94538 510 623 9600 Voice 510 623 9602 Fax WARRANTY The material contained in this document is provided as is and is subject to being changed without notice Further to the maximum extent permitted by applicable law Loadstar Sensors disclaims all warranties either express or implied with regard to this manual and any information contained herein including by not limited to the implied warranties of merchantability and fitness for a particular purpose Loadstar Sensors shall not be liable for errors or for incidental or consequen
3. c If an enable field is selected the decimal point lights will turn on enable or turn off disable the currently selected ports 4 Press enter to retain the newly changed value Loadstar Sensors Inc Page 16 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 7 QUICK PROGRAMMING HOW TO TiPS 7 1 How to change the displayed decimal point location 1 Press the down button bottom right and holding it down press enter bottom left Now release the down button while continuing to hold down enter While continuing to hold enter press up top right or down bottom right to select your desired decimal point location The current decimal point location is illuminated on the display while you continue to hold down the enter button 4 Release enter when the decimal point is at the desired position The display will retain this new decimal point selection until changed again or reset to the factory default 7 2 How to reset or TARE the current displayed value to zero 1 Press and hold the enter button until the display shows tArE and all the decimal points for all the currently active sensors illuminate Releasing the button will now tare all the connected and active sensors 7 3 How to display the load from only sensors I choose 1 Press and hold menu until EntEr PASS and 500000 appear on the display Press the up or down keys to select the programming mode password default is 20000 1 Press enter
4. 1 CTO Tare all sensors ETT lt gt Ext tare function D Disabled T Tare R Trigger B Bothl TIS TTH Sensor tare type Soft Hard SST Sensors internal status code LED lt gt LED brightness 10 125 ST lt gt Sleep Timeout seconds 0 99 Disabled R1TP1 lt gt RITP2 lt gt Relay 1 s two trigger points R2TP1 lt gt R2TP2 lt gt Relay 2 s two trigger points R1TP1T lt gt R1TP2T lt gt Relay 1 s trigger point type TA TB RA RB R2TP1T lt gt R2TP2T lt gt Relay 2 s trigger point type TA 1TB RA RB R1S1 lt gt R1S4 lt gt Sensor s relation to relay 1 Sum I Ind N Nonel R2S1 lt gt R2S4 lt gt Sensor s relation to relay 2 Sum I Ind N None R1D lt gt Relay 1 s duration in seconds 0 0 continuous R2D lt gt Relay 2 s duration in seconds 0 0 continuous ASH RSH Add Remove sensor s load from display MODEL Returns D 3000 lt cr1f gt UNIT lt str gt Calibration units mLB g N SETTINGS Returns configuration settings x x C 2007 Loadstar Sensors Inc Ver 3 05 01 05 10 14 21 x x Connected 0 02 09 Note that it is planned that nearly every command accessible by the front panel interface will be accessible remotely The next section will describe each of these commands in detail Loadstar Sensors Inc Page 40 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 11 REMOTELY PROGRAMMIN
5. When active the RED light is on when inactive the YELLOW light is on 4 Make sure the DS 3000 is set to units of Lbs so press the up key until the pounds front panel lamp is illuminated So Senna Seca as es eee een YELLOW RED OUTPUT 1 COM gt DS 3000 Figure 10 Wiring diagram for program example 2 9 2 3 Programming the DS 3000 1 Press and hold menu until EntEr PASS and 000000 appear on the display Press the up or down keys to select the programming mode password default is 20000 1 Press enter A V N You are now in programming mode at the d5P A4 prompt Press mode until you reach the rELAY I menu 5 Press down to thetr3r I entry Press enter and a numeric entry field will appear Enter the Relay 1 threshold of 40 Lbs Press menu until the digit corresponding to the 4 is highlighted then press up and down to set the digit to 4 Press mode again to highlight each digit in turn then up and down to set each one to the correct value Please note the decimal point location 6 Press enter when you are complete Press down to get to the next programming entry 7 Select Prt Itb for Prt I using the enter key to select Loadstar Sensors Inc Page 31 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 8 Press downtotr9r 2 press enter and a new numeric field appears Enter the threshold of 40 Lbs Press enter when completed Although this example does not use it it might be a good
6. Then press enter to return to run mode Closing the remote contacts will now automatically tare sensors same as the onscreen tare pushbutton 7 7 How do I enable the remote tare function Press and hold menu until Ent amp PASS and 000000 appear on the display 2 Press the up or down keys to select the programming mode password default is 00002 3 Press enter 4 You are now in programming mode at the d5P A4 prompt Press mode until you reach the ort ian menu 5 Press down to the t 5t entry Press enter until E 9t E is displayed Now exit programming mode Press mode until the r n entry Then press enter to return to run mode Closing the remote contacts will now automatically tare sensors same as the front panel enter pushbutton 7 8 How do I change the display brightness 1 Press and hold menu until EntEr PASS and 000000 appear on the display Loadstar Sensors Inc Page 18 48 033 01419 Rev 4 DS 3000U DS3000 User Guide Press the up or down keys to select the programming mode password default is 00000 1 Press enter 4 You are now in programming mode at the d5P A4 prompt Press mode until you reach the ort ion menu Press down to the LEd entry Press enter and a numeric field appears onscreen Press down and up until the desired brightness is achieved Maximum brightness is 128 and minimum is 10 Default is 64 If power consumption is a concern the power requirements doub
7. a name and choose an icon for the connection Name DS 3000 Bes teu te dets an Anett SCROLL CAPS NUM Capture Print echo Select the virtual comport DS 3000 HyperTerminal File Edit View Call Transfer Help Dees 2828 Connect To B DS 3000 Enter details for the phone number that you want to dial jon United States 1 v 0 ing Agere Systems HDA Modem SCROLL CAPS NUM Capture Print echo and the default baud rate and communication settings Loadstar Sensors Inc Page 38 48 033 01419 Rev 4 DS 3000U DS3000 User Guide COM30 Properties Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow control None Press OK to connect to the DS 3000 Pressing enter on your keyboard should be acknowledged by the DS 3000 with A DS 3000 HyperTerminal File Edit View Call Transfer Help DF 84 D You may type enter to get a list of all commands Loadstar Sensors Inc Page 39 48 033 01419 Rev 4 DS 3000U DS3000 User Guide DS 3000 HyperTerminal File Edit View Call Transfer Help D 928 25 amp GE DS 3008 Help Menu x x x x x x s s s x x 00WO OOW1 00X1 Gross weight W sum X A11 0 constant 1 oncel SLC lt gt Show load capacity of displayed sensors CS0 CS1 lt str gt Configure Show user strings S
8. a new numeric field appears Enter 1 0 Lbs Press enter when completed Select Pnterb for Pake using the enter key to select This will reset the output once it drops below this threshold nime Press down to 5En I corresponding to sensor 1 Press enter until i is displayed This means that the trigger condition will only look at sensor 1 Finally press down to dur Atn press enter and make sure it is set to cont in Loadstar Sensors Inc Page 35 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 12 13 14 15 16 17 Press enter to leave this field Press menu till oPt ion page is displayed Press down to tr9t press enter until E 9t b is displayed This enables the remote input to tare the DS 3000 whenever the external contacts are closed and reset the measurement state machine at the beginning of each new cycle Now exit programming mode Press mode until the Un entry Then press enter to return to run mode Once in run mode the program is now operational Loadstar Sensors Inc Page 36 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 10 REMOTELY CONNECTING TO THE DS 3000 The optional programmable relay and external trigger capability of the DS 3000U make it a very powerful and versatile instrument to control laboratory experiments process control equipment production test systems etc In addition to the DS 3000s stand alone control abilities additional remote programming and
9. contact Tares all connected sensors r Reset Restart the internal program running on Relay 1 b Both i e tares all sensors and restarts the internal program on Relay 1 ud GS Current DS 3000U firmware revision essed Select new password for accessing programming menus Be sure to remember any new password Programming mode is not accessible without the current password FActor Restore factory default settings on DS 3000U Press and hold enter to select Summary Miscellaneous options menu 8 2 8 Run Function Restore RUN mode Keystrokes Press menu key till Un is displayed then press enter Summary Exits DS 3000 programming mode and returns to run mode where the display shows the output of selected sensors Loadstar Sensors Inc Page 27 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 9 DS 3000U SYSTEM PROGRAMMING EXAMPLES 9 1 Tank Fill Controller A mining concern has a large slurry tank with 4 load cells mounted on each of it s four legs Before rock is added a certain amount of water must be initially present in the tank This is can be easily accomplished using the PLC like functionality of the DS 3000 An external trigger from the main plant process controller triggers the process start and tares the DS3000U then water is added under control of the DS 3000U output 1 Once the weight of tank water exceeds the desired setpoint the DS 3000 stops the water flow int
10. contact 1 related parameters Keystrokes Press menu till ELAY I is displayed then press up or down to select which parameter you d like to adjust then press enter to edit each entry to the desired value These parameters affect Relay Output 1 only Relay 1 and Relay 2 are independent and are programmed separately First trigger action threshold Select enter to enter the numeric entry field up and down changes the value of the currently highlighted digit and menu changes the currently highlighted digit Press enter when finished Pnt IER Activate output 1 above this value ie Trigger Above Pnt Itb Activate output 1 below this value ie Trigger Below Prt I A Reset output 1 above this value ie Reset Above Prt irb Reset output 1 below this value ie Reset Below Second hysteresis action threshold Select enter to enter the numeric entry field up and down changes the value of the currently highlighted digit and menu changes the currently highlighted digit Press enter when finished Loadstar Sensors Inc Page 24 48 033 01419 Rev 4 DS 3000U DS3000 User Guide PnkekA Activate output 1 above this point Prt tb Active output 1 below this point a Prte A Reset output 1 above this point a Paterb Reset output 1 below this point Include Sensor 1 in Sum with other sensors S individually I or not included blank
11. idea to choose some hysteresis to avoid the output pulsing if the weight fluctuates around the set point 9 Select PaterA for Panke using the enter key to select This will reset or de activate the output once activated when the load rises above 40 Lbs 10 Press down to 5En corresponding to sensor 1 Press enter until 5 is displayed This means that the trigger condition will include the sum of sensor 1 11 Press down and repeat for 5Eng SEn3 and SEnY This way the sum of all four sensors will be used to determine the trigger criteria 12 Finally press down to duUrAtn press enter and make sure it is set to cant in This means the output will remain activated until reset by the Pnt condition above once triggered by the Pat condition 13 Press enter to leave this field Next we will program output 2 14 Press mode until you reach the rELAY 2 menu 15 Press down to the E 9r I entry Press enter and a numeric entry field will appear Enter the Relay 2 threshold at 70 Lbs Press menu until the digit corresponding to the 7 is highlighted then press up and down to set the digit to 7 Press mode again to highlight each digit in turn then up and down to set each one to the correct value Please note the decimal point location 16 Press enter when you are complete Press down to get to the next programming entry 17 Select Pnt itb for Pnt I using the enter key to select 18 Press down to tr3r press enter and a
12. new numeric field appears Enter the threshold of 70 Lbs Press enter when completed 19 Select PntcrA for Pake using the enter key to select This will reset or de activate the output once activated when the load rises above 70 Lbs 20 Press down to 5En I corresponding to sensor 1 Press enter until 5 is displayed This means that the trigger condition will include the sum of sensor 1 21 Press down and repeat for SEnc 5En3 and 5En4 This way the sum of all four sensors will be used to determine the trigger criteria 22 Finally press down to dirfitn press enter and make sure it is set to cont in 23 Press enter to leave this field 24 Now exit programming mode Press mode until the Un entry 25 Then press enter to return to run mode 26 Once in run mode the program is fully operational 9 3 Go NoGo Acceptable Weight Limit Test In many production processes a fully packaged product has a very specific weight If the weight deviates above or below that value by only a small amount there is likely a problem with that product and it should be shunted off the production line for further investigation This application monitors a remote contact which is enabled when after a product is deposited on a scale composed of a single sensor The DS 3000 then weighs the device and if it falls above or below a predetermined threshold activates it s output in turn causing a mechanical flapper to alter the path of the pr
13. of the Use of Certain Hazardous Substances in Electrical amp Electronic Equipment as amended by EU Commission Decision 2005 95 EC This product is ROHS Compliant 2005 95 EC RoHS Compliant 2005 95 EC means that the product or part Product does not contain any of the substances in excess of the maximum concentration values in EU Directive 2002 95 EC as amended by Commission Decision 2005 618 EC unless the substance is in an application that is exempt under EU RoHS Unless otherwise stated by Loadstar sensors in writing this information represents Loadstar Sensors best knowledge and belief based upon information provided by third party suppliers to Loadstar Sensors In the event any product is proven not to conform to Loadstar Sensors Regulatory Information Appendix then Loadstar Sensors s entire liability and Buyer s exclusive remedy will be in accordance with the Warranty stated below WEEE Directive 2002 96 EC The Waste Electrical and Electronic Equipment Directive WEEE applies to companies that manufacture sell and distribute electrical and electronic equipment in the E U It covers a wide range of large and small household appliances IT equipment radio and audio equipment electrical tools telecommunications equipment electrical toys etc Loadstar Sensors Inc Page 3 48 033 01419 Rev 4 DS 3000U DS3000 User Guide The Directive aims to reduce the waste arising from electrical and electronic eq
14. 1F no battery 15 to 113F with internal battery 5 to 185F no battery 5 to 140F with internal battery Humidity Voltage Power Vibration Shock Enclosure Construction Material Bezel Dimensions Display Type Active Digits Remote TARE Contacts Closed contacts Open contacts Cable Length Remote RELAY OUT contacts Surge withstand voltage Maximum Resistive Load Maximum Inductive Load Maximum contact voltage Abs Max contact carry current Maximum contact switching Special Interfaces Host Interface Sensor Interface CE Marking Loadstar Sensors Inc 5 to 85 RH Non Condensing 6 to 32 VDC Up to6 W Not to exceed 4 mm displacement at 16 7 Hz for greater than 60 mins Not greater than a 20 cm drop onto a hard wooden surface ABS Plastic Acrylic 4 7 in 120 mm x 1 4 in 38 mm x 2 8 in 80 mm 7 Segment RED LED 6 Digits 0 4 high Minus indicator and decimal points logic low or active input to the unit logic high or inactive input to the unit 100 feet 20 Gauge wire Meets FCC Part 68 and Telcordia 2 5 kV Specifications 10A at 125 VAC 4A at 125 VAC snubber highly recommended 250 VAC or 220 VDC at reduced current 15A 50 VA capacity USB virtual COM USB host Page 47 48 033 01419 Rev 4 DS 3000U DS3000 User Guide EMI EN5022 EMC EN55024 Safety EN60950 EN60950 1 Loadstar Sensors Inc Page 48 48 033 01419 Rev
15. 33 01419 Rev 4 DS 3000U DS3000 User Guide WARNING 1 Do not use the display with the cover or part of the cover removed or loose as a hazardous condition may result Inspect the case for cracks or missing plastic Do not use if the display is damaged 2 Use only AC Adapter Charger s which conforms to the display required voltage and current ratings provided 3 Do not operate the display in an explosive atmosphere or in the presence of flammable gases or fumes 4 Do not immerse the display in liquid the housing is not fluid tight Humidity specifications are specified as non condensing only 5 Do not substitute parts or modify the display box to avoid the introduction of additional hazards Return the display to Loadstar sensors office for service and repair to insure all safety features are maintained 6 When the built in Li lon Polymer battery option is present take care not to a Operate or store the display in temperatures beyond 20C to 60C Battery failure may occur b Excessive barometric pressure changes may also cause the battery to fail or outgas This display is not to be used within a pressure vessel or vacuum environment for example c Excessive physical damage or severe product impact may cause battery failure Units showing evidence of physical damage should be returned to the factory for service and repair RoHS WEEE COMPLIANCE STATEMENT EUROPE Directive 2002 95 EC Restriction
16. 4
17. ED contacts under program control e Each relay is independently programmed and activated Output logic sequencing load band activation sensor hysteresis set point control and pulsed output periods are all user programmable e Password protected menu for program protection e All programming parameters are automatically stored in non volatile memory e Optional Lithium lon Polymer backup battery can be used to keep DS 3000 and attached sensors alive during power failure conditions The internal battery is automatically recharged when sufficient external power is available A convenient front panel indicator shows when the internal battery is charging Loadstar Sensors Inc Page 9 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 4 PHYSICAL DETAILS The following pictures of the DS 3000 Display module show the locations of all exterior connections the user interface and the optional mounting base Descriptions of each are in the following sections 4 1 DS 3000 Physical Orientation SHIFT MENU menu UP UNITS up Load Sensin Pa Batjelb kglen Sleep 6 UNITS 6 D ad tar SENSORS g Mad i Easy Ma a amp T RE FUNCTION 4 Chan l Display DS 3000 Optional Mounting Base DOWN FUNCTION down ENTER TARE enter Figure 1 DS 3000 Top View User Interface Sensor 1 Sensor 2 Sensor 3 Sensor 4 Figure 2 Side View Input Sensor Connectors Loadstar Sensors Inc Pag
18. G THE DS 3000 It is planned for nearly every command to be programmed into the DS 3000U remotely The variable n corresponds to relay 1 or 2 and the variable x corresponds to a port 1 4 In the commands which follow should be replaced with the correct relay port information ea EL the n and x TE PC Control Command Overview 11 1 o0W0 o0W1 00X12 Function Keystrokes Output Weight Commands Output Weight commands return the currently displayed weight on the DS 3000U to the host PC If the displayed weight is modified by DS3000 programming to exclude some sensor inputs that modified value is returned by default 00X1 will output all sensors regardless of programming settings oOWO lt gt Output gross weight continuously in the currently selected units oOW1 Y Output gross weight once in the currently selected units 00X1 gt Output all sensors individually including the sum Summary 11 2 SLC Function Output current gross weight to host PC These outputs are read only values Summary Show Load Capacity Normally the DS 3000 automatically calculates the load capacity based on the load capacity of connected sensors For example the load capacity of a single sensor is the load capacity of that sensor The load capacity of two sensors is the sum of the load capacities of each In general the SLC command returns the sum of the load capacities of a
19. IT Future Command Not yet implemented Function Sets currently active display units 11 17 SETTINGS amp Function Returns current configuration settings Keystrokes This command returns the current system configuration and programming settings SETTINGS Summary Returns current configuration settings A settings DS3000 Settings V3 05 Loadstar Sensors Inc Page 45 48 033 01419 Rev 4 DS 3000U DS3000 User Guide S50 12345 SS1 DAVID DISPLAY Sl On S2 On S3 0n S4 On Tare Type Soft Units MLB LED Brightness 10 125 64 Relay 1 Trigger Point l ra 0 200000000E1 Trigger Point 2 rb 0 400000000E0 Using Sensors Sl sum sum S3 sum S4 sum Duration 0 100000008E 2 seconds 0 continous Relay 2 Trigger Point l ra 0 0E0 Trigger Point 2 rb 0 0E0 Using Sensors S1 82 3 S4 Duration 0 100000008E 2 seconds 0 continous Sleep Time Out 0 seconds 0 disabled External Tare both Loadstar Sensors Inc Page 46 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 12 DS 3000 TECHNICAL SPECIFICATIONS Performance Resolution Displayed Resolution Update Speed Display Sensitivity Software Filter Temp Coefficient Environment Operating Temperature Storage Temperature 999 999 total counts Dynamic Sensor Dependent 10 display updates second Sensor dependent None N A Sensor dependent 10 to 55C 10 to 45C 20 to 85C 20 to 60C 15 to 13
20. RON You are now in programming mode at the d5P AY prompt Notice the decimal points are flashing for inactive ports and solid on for active ports 5 Press down one time to the d 5P I menu Press enter to enable or disable this port from being displayed It is displayed if the decimal point corresponding to the port is illuminated it is NOT displayed if the port is extinguished 6 Press down as above for d 5P 2 diSP J d 5P 4 leaving only the ports you want illuminated or enabled 7 Press up to dSPLAY and confirm that the decimal point is not illuminated on the ports you ve disabled Press mode until the rUn entry Then press enter to return to run mode Your display will now only show the sum of the ports you ve chosen 7 4 How do I tare only one connected sensor 1 Press and hold menu until EntEr PASS and 000000 appear on the display 2 Press the up or down keys to select the programming mode password default is 20000 1 3 Press enter 4 You are now in programming mode at the d5P A4 prompt Press mode until you reach the EArE menu page 5 Press down to the menu entry corresponding to the sensor you want to tare from sensor 1 gt EArE I to sensor 4 gt LArE 4 Loadstar Sensors Inc Page 17 48 033 01419 Rev 4 DS 3000U DS3000 User Guide Press enter to tare the selected sensor The chosen port decimal point will flash when taring is completed You may individually tare any sensors you l
21. ability and Buyer s exclusive remedy will be in accordance with the Warranty stated below China RoHS is a two step process that identifies concentration limits of certain hazardous substances in electronic information products that are sold into China Per the deadline set by the Chinese government March 1 2007 Loadstar Sensors has implemented step one of China RoHS self declaration of hazardous materials and marking of the product Loadstar Sensors display modules Loadstar Sensors Inc Page 4 48 033 01419 Rev 4 DS 3000U DS3000 User Guide that are sold into the China market have the required marking on the product designating that the product meets the China RoHS requirements The second step involving a testing obligation is currently under development Full compliance will follow once it has been finalized Table of contents 7 IWANT TO E E nemes Sephadat heaeedel odes d aedadet l sms rmsdnemeen hdmi 7 2 ANTRODUCTION ER 8 3 MODULE FEATURES i sesaseasessaisusdatetncusd mei tene a e e E EaD E EEE D EEE EES 9 4 PHYSICAL DETAI S eere enera aa aaaea Eaa Ee a aa ae aa Eaa eE E OAE AE NEEE EERE Ea SEEE 10 4 1 DS 3000 Physical Orientation cc cccceceeecceeeeeceeeeeeceeeeeeeeeeeeeeaaeceeeeseaeeeeeeneeeeeenenaees 10 4 2 DS 3000 Mechanical Dimensions cccccceeeecceeeeeeeeeeeeeeeeeeeeeeaeeceeeeecaeeeteseeeeseesenaees 12 5 OPERATION QUICK START GUIDE nnnnnnnnnnnnnnnnonnnnnnrnrnnnnnnnrnnnnnnnr
22. abled disabled decimal point lights when enabled di SPI W Display connected Sensor 1 di SP2 amp Display connected Sensor 2 di 5P3 I Display Connected Sensor 3 di SPY W Display Connected Sensor 4 Factory default is for all 4 displays to be on Loadstar Sensors Inc Page 23 48 033 01419 Rev 4 DS 3000U DS3000 User Guide Summary Select which sensor or combination of sensors is currently displayed on the front panel LED display Does not affect the value returned by the USB uplink port to a connected PC all four summed 8 2 3 Tare Options Menu Function TARE Connected Sensors Keystrokes Mode Key menu till A E is displayed then press up or down to select input sensor to tare then press enter FATE Ig Tare connected Sensor 1 LArE 2 amp Tare connected Sensor 2 LArE 3 amp Tare connected Sensor 3 EAE 4 g Tare connected Sensor 4 kYPE NOTE Tare all connected Sensors simultaneously is done using enter key in run mode Press enter to toggle between EYPE h and EYPE 5 Most applications should use E4PE h or hard tare If you have an application that requires very frequent tares gt 10 hour EYPE 5 or soft tare may be more appropriate Please contact Loadstar Sensors support for more information Summary Manually Tare individual sensors Set the type of tare command sent to the sensors 8 2 4 _ Relay Output 1 Menu Function Setup output
23. ation Requirements rnnnrrrnnnnnnvonnnnnnnnvrrnnnnnnrrnnnnnnnnnrrnnnnnerrnnnennnnvrrennnssernneennnn 34 9 4 2 Implementation Details rrrnnnvrrrrnrrnnnnnrrnnnnrrrnnnnnnrnnnrrnnnnnrnnnnnnnennnrnnnnnrrrnnnnnsrenneennnn 34 9 4 3 Programming the DS 3000 ccceccceeeeeceeeeeeeeeeeeeeceeeeeeeeeaeeeeeseeeteeseseeeesesnnaeeess 35 10 REMOTELY CONNECTING TO THE DS 3000 ceccceeeceeceeeceeeeeeeeseeeeeeeeseeeesneeeeeeeeeees 37 10 1 Installing Virtual com port drivers 0 eee eee eeeteee eee eeeeeeeeeeeaeeeeeeeeeeeeeeeeeaaeeeeeeeeeeeeeeeeaaa 37 10 2 Communicating with the DS 3000 using Hyper terminal cceeeeeeeeeeeeeeeeteeeeees 37 11 REMOTELY PROGRAMMING THE DS 3000 c ccceccceeeeceeeeceeeeeeeeeeeeseeeeeeeeeeeeseeeeneeeeees 41 17 4 EONO GONT OOX IT marinaden anden makt E E E 41 T2 SO 41 11 3 CSO ES occ ccccccecdeesececenecstenceeeedcescisaesnnccetgecessencsenecnevsceesscasnsanccensecerscnstineness 41 ACTO S oa e r e a a a ute ped ata eacace a 42 11 5 ETT Future Command not yet implemented rrnnrrrnvrrnvrrnvrrnvrrrnrrrnvrrnvrrnvrrnnrrnnnenn 42 116 115 ca Ne 42 TL SST as 42 11 8 LED Future Command Not yet Implemented rrnnrrrnvrrnvrrnrrrnvrrnvrrrnvrrnvrrnvrrnnrrnnnnnn 42 11 9 ST amp Future Command Not yet Implemented rrrrrnrrnrnrrrnnrnnrnrnrnrrnnrnnnrnnnnrnnnnrnnnnr 43 11 10RNTPx lt Future Command Not yet implemented rrrrnrrrnrrrnvrrn
24. e 10 48 033 01419 Rev 4 DS 3000U DS3000 User Guide POWER INPUT USB HOST Figure 3 End View Power and USB Host Connections Loadstar Sensors Inc Page 11 48 033 01419 Rev 4 DS 3000U DS3000 User Guide dte pl eet AAAS Remote contacts TARE TRIGGER Contact 2 Contact 1 Figure 4 End View Wiring Adapter Socket 4 2 DS 3000 Mechanical Dimensions 4X 177 THRU ALL 370 X 90 Figure 5 DS 3000 Top View Includes optional mounting base Loadstar Sensors Inc Page 12 48 DS 3000U DS3000 User Guide Figure 6 DS 3000U Mechanical Host End View 4 724 925 1 665 2 405 rf 3 145 591 Figure 7 DS 3000U Mechanical Side View Loadstar Sensors Inc Page 13 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 5 OPERATION QUICK START GUIDE When power is first applied to the DS 3000 Series display all segments of the LED display will be momentarily illuminated 68888688 while the instrument goes through an internal self test procedure When the self test is completed the unit will display the LoAdStAr SEnSorS d5 3000 banner then display the load on the attached sensors in either the factory programmed way SUM of ALL attached sensors or in the way most recently set within the programming menu 5 1 Quick Operation and Programming Over
25. e process cannot be restarted until the remote input is triggered again 10 Press down to 5En corresponding to sensor 1 Press enter until 5 is displayed This means that the trigger condition will include the sum of sensor 1 11 Press down and repeat for 5Eng SEn3 and SEnY This way the sum of all four sensors will be used to determine the trigger criteria 12 Finally press down to duUrAtn press enter and make sure it is set to cant in This means the output will remain active during the whole time nly pulse for this interval when either the minimum or maximum condition occurs 13 Press enter to leave this field 14 Now exit programming mode Press mode until the Un entry 15 Then press enter to return to run mode 16 Once in run mode the program is now fully functional and operating Try it out 9 2 Empty Tank Warning This application uses a scale platform made with 4 sensors mounted on the corners of a square slab of Aluminum with a tank of liquid in this example a nitrogen Dewar atop the platform Liquid Nitrogen over time is used up and the tank slowly loses weight At some point the weight is reduced to the point where the Dewar needs to be replaced Since the replacement process can take a day or more some advanced warning is appropriate Therefore this application has two lights yellow which indicates the Dewar should be scheduled for replacement and red which signals the Dewar is empty and should be r
26. educing WEEE and helping the environment by separating out WEEE and disposing of it properly Consumers can ask the supplier from whom they purchased the Electronic amp Electrical equipment from about local arrangements for the disposal of WEEE Business users are advised to ensure that WEEE which is not suitable for reuse or recycling be disposed of properly via approved authorized treatment facilities The Producer in your country may be able to assist you Loadstar sensors is dedicated to minimizing the impact our products have on the environment and to comply with the WEEE Directive ROHS in China Electronic Industry Standard of the People s Republic of China SJ T11363 2006 Requirements for Concentration Limits for Certain Hazardous Substances in Electronic Information Products This symbol per Marking for the Control of Pollution Caused by Electronic Information Products SJ T11364 2006 means that the product or part does not contain any of the following substances in excess of the following maximum concentration values in any homogenous material a 0 1 by weight for cadmium Unless otherwise stated by Loadstar Sensors in writing this information represents Loadstar Sensors best knowledge and belief based upon information provided by third party suppliers to Loadstar Sensors In the event any product is proven not to conform with Loadstar Sensors Regulatory Information as provided herein then Loadstar Sensors entire li
27. eeeeecsaeeeeesseaeeees 18 7 7 How do I enable the remote tare function arrrnrrrnnrrnnrrnrnnnrrrrnnnrnnrrnnnnnnrrnnnnnnrrnnnnnnennnn 18 7 8 How do I change the display brightness ccsecceceeeeeceeeeeeeeceeeeeeeeeeeeeseeeeeeeeeneeees 18 7 9 How do I turn off attached sensor ports to Save POWEI mmrrnrrnnnrnnrrnnnnrnnnnnnrrrnnnnnrennnn 19 7 10 How do I change the password rmnrrnnvnnrnnrnnrrnnrrnnrnnnrrnnnnnnenrnnnnnerrnnnnnnnnrrnnnnnnrnnnnnenennnn 19 7 11 What if I ve lost the password How can I get into program mode rrnnnnnnnnnnnrnnnnnnrrnnnn 20 7 12 How do I reset the unit to factory defaults mmrrnnnnrnrnrrnrrrnrrnnrnnnrrnrnnnnnnrrnnnnnnrnnnnnnnerrnn 20 7 13 Is there an easy way to see what is currently programmed aannnnnnnvrrnnnnnnnnnnnnrrrnnrnnnnnner 20 7 14 How do I check my programming snnnnnnnnrnnnnnnnnnrnnnnnnrrn nn nnnnrnnnnnnnrnnnnnnrrnnnnnnnnrrnnnnenennnn 20 8 COMMAND REFERENCE rnnnnrnnnrnnrrnnnrnnrnnrnnrrnnnnnrrnnnnnnnnrrnnnnnnrnn nn nnnnnrnnnnnnrrnnnnnnenrnnnnnnnrnnnnnnen 22 8 1 Run Mode Command Descriptions cccccceceecceeeeeeeeeeeeeeeeeeeeeeeeeeeseeseneeeeeeseeeeeneaes 22 8 1 1 Tare All Sensors isaidie iiias eenaa aee aaar aas AEE eaaa EEEa a E EEEa 22 8 1 2 Set Displayed Units rnrrnnnnnrnnrrnnrnnrrnnnrnnnnrnnnrnnnnnnnrn ann eaeeeeesaaeeseeeeaeeeeeseaeeeessneeaeeess 22 8 1 3 Enter Programming Mode renrnnnnnnvrnnnvrrnnnnnnnnnnnvvrrnnnnn
28. eplaced With both lights off there is nothing to do Table 1 Dewar Replacement Chart Relay 1 N O N C N C Relay 2 N O N O N C a ae B 0 Lbs 40 Lbs 7OLBS 250 Lbs 9 2 1 Application Requirements 1 4x sensors each with 250 Lb load capacity each 1000 Lb total scale load capacity 2 Assume this Dewar has a full weight of 250 Lbs and an empty weight of 40 Ibs If typical usage is 15 Lbs day and it takes 2 days to receive a shipment then the yellow light should activate at 30 40 70 Ibs and the red light at 40 Ibs tank empty 3 Let Sensor 1 Sensor 4 correspond to the four load cells mounted to the measurement plate Each is connected to one of the four DS 3000 module inputs Loadstar Sensors Inc Page 30 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 9 2 2 Implementation Details 1 Connect the red light to Output 1 NO Terminal Connect the yellow light to Output 1 NC terminal Connect the COM terminals for output 1 and output 2 together Power the NO terminal of Output 2 and the remaining terminals on the lights with the source See Error Reference source not found 2 Set Output 2 to activate BELOW 70 Ibs and de activate when above 70 Ibs Thus when the Dewar weight is above 70 Ibs no lights will illuminate When less than 70 Ibs Output 1 will determine which light is illuminated 3 Set Output 1 to activate at 40 Ibs and de activate above 40 lbs
29. igure 7 DS 3000U Mechanical Side View ccccccecceeeeeeeeceeeeeeeeeeeeeeaeeeeeseeeeeseseaeeees 13 Figure 8 What you need to get started with the DS 3000 merrrsnnrnnrrrnrrrnrrnnnnrnnnrrnnnnnnnnnnn 15 Figure 9 Wiring for Program Example 1 cccccccceeeeceeeeeeeeeeeeeeeeeeeeeecaeeeseeseeeeseneaeeees 29 Figure 10 Wiring diagram for program example 2 cccccccceeeeeececeeeeeeeeeeeeeeeeteeseaeeees 31 Figure 11 Schematic for Program Example 3 ccccccccceeeeceeeeeeeeeeeeeeecaeeeseeseeeeteneeaeeees 33 Figure 12 Schematic for Program Example 4 ccccccccceeeecceeeeeeeeeeeeeeeecaeeeeeeeeeeeeeeneaeeess 35 Loadstar Sensors Inc Page 6 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 1 IWANT To 1 Quickly understand the DS 3000 user interface or 2 Get Started Quickly with the DS 3000 OPERATION QUICK START GUIDE dansen ean EEE E 14 In 3 Get to programming mode on the DS 3000 RUNNING OR PROGRAMMING ccc cesececcesessceesessenescetasonssecascnsacenatecscsensessscnesesesins 16 ID 4 See a list of common DS 3000 programming tips 7 QUICK PROGRAMMING HOW TO TIPS uu cn 0 cccccccccsecccesssoccesssnsecsessadenseeseasectceensentertaaecscenas 17 5 Look at some Example DS 3000 Program Examples 9 DS 3000U SYSTEM PROGRAMMING EXAMPLES ccccccccccssccccssseececesssseeceesseeseseessaeeees 28 6 Fi
30. ike in this manner Exit programming mode when completed Press mode to the r n entry Then press enter to return to run mode The display will now reflect the new result based on the newly tared sensor 7 5 How can I tell which sensors are currently being displayed PQ N Press and hold menu until EnkEr PASS and 000000 appear on the display Press the up or down keys to select the programming mode password default is 00200 1 Press enter You are now in programming mode at the d5P AY prompt Notice the decimal points are flashing for inactive ports and solid on for active ports Thus any port with a solid decimal point is summed in the current display mode Any flashing port is enabled to be summed but is currently inactive and not summed displayed because no sensor is currently installed in that port position To exit back to run mode Press mode until the Un entry Then press enter to return to run mode 7 6 How do I get the firmware version 1 Press and hold menu until EntEr PASS and 500000 appear on the display Press the up or down keys to select the programming mode password default is 20000 1 Press enter A VN You are now in programming mode at the J5PL A9 prompt Press mode until you reach the ort ian menu 5 Press down three times to the ui 05 this is the current firmware revision At the time of this writing version 3 05 6 Now exit programming mode Press mode until the Un entry
31. is is a debug command SST I Returns internal status code Summary Returns internal status code This is a read only value 11 8 LED Future Command Not yet Implemented Function Sets intensity of display LED Loadstar Sensors Inc Page 42 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 11 9 ST Future Command Not yet Implemented Function Sets sleep timeout 11 10RANTPx lt Future Command Not yet implemented 11 11RATPXT amp Future Command Not yet implemented Function Relay 1 and Relay 2Trigger Points Function Relay trigger point type Loadstar Sensors Inc Page 43 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 11 12RnSx lt Future Command Not yet implemented Function Sets sensor x relationship to Relay n 11 13RND Future Command Not yet Implemented 11 14ASx RSx Future Command Not yet implemented Function Relay n duration Function Adds or Removes sensor from current display sum Loadstar Sensors Inc Page 44 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 11 15MODEL amp Function Returns model number of connected device Keystrokes This command returns the current model number of the device connected to this virtual serial interface MODEL Request the model of the currently attached device to this virtual COM port Summary Returns DS3000 lt CRLF gt 11 16 UN
32. l input or programmed to respond to complex sensor load set point combinations Relay outputs may be activated and de activated on pre selected loading criteria based on single sensors or multiple sensor sums The built in host USB uplink port connects to your PC for simplified remote control or remote data collection Either your virtual serial port based software or Loadstar Sensors windows based LoadVUE Software can be used to log and chart displayed data from the DS 3000U Loadstar Sensors Inc Page 8 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 3 MODULE FEATURES e Power input may be provided either by the provided AC adapter 90 250 VAC 50 60 Hz or an optional DC input pigtail 9 32 VDC e Precise six digit display plus sign 9 9 9 9 9 9 9 9 9 9 9 9 provides properly scaled output in selectable units and precision for compatible Loadstar sensor inputs e Connected sensor s are powered by the display module No additional power supply is required e Front panel TARE button to simultaneously zero all connected load cells e Front panel UNITS button to conveniently toggle display units between LBS KG or N e Front panel SHIFT ENTER UP and DOWN buttons for access to the powerful programming menus e Remote input connector contacts may be used to synchronize the internal program or tare currently connected sensors e Dual SPST relay contacts provide NO Normally OPEN and NC Normally CLOS
33. le from 64 to 128 so it is recommended that you choose the minimum value which is acceptable for your application Press enter to retain your final setting The display changes immediately when this value is edited so it is easy to determine the best value Now exit programming mode Press mode until the r n entry Then press enter to return to run mode The display will now retain your newly set display brightness even when powered off then powered back on 7 9 How do I turn off attached sensor ports to save power 1 Press and hold menu until EntEr PASS and 000000 appear on the display Press the up or down keys to select the programming mode password default is 00000 1 Press enter RON You are now in programming mode at the d5P AY prompt Press mode until you reach the Pol Er menu 5 Press down to the 5 entry Press enter to toggle this port on or off 5 i corresponds to port 1 52 corresponds to port 2 53 to port 3 and 54 to port 4 Now exit programming mode Press mode until the r n entry Then press enter to return to run mode 7 10 How do I change the password 8 Press and hold menu until EntEr PASS and 000000 appear on the display 9 Press the up or down keys to select the programming mode password default is 20007 1 10 Press enter 11 You are now in programming mode at the d5P A4Y prompt Press mode until you reach the art ion menu 12 Press down to the PASS entry Press enter t
34. ll connected sensors This is a read only value 11 3 CS0 CS1 SSO SS1 Function Keystrokes User Strings These commands set and read user programmable text strings String CSO Is typically used for the DS 3000 Serial Number and CS1 is used for an easy to remember text name used to differentiate this DS 3000 from others that may be present in your system Summary CS0 12345 p Program Serial Number to 12345 CS1 BOX1 Y Program Device Name to BOX1 sso Display current Serial Number ssiv Display current Device Name Set and read user programmable text strings Loadstar Sensors Inc Page 41 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 11 4 CTO amp Function TARE all currently connected sensors simultaneously Summary This remote command tares all connected sensors at the same time 11 5 ETT amp Future Command not yet implemented 11 6 TTS TTH amp Function Set function of external input Function Set tare type Keystrokes These commands tell the DS 3000 how to handle default tare requests TTS Soft tare attached sensors equivalent to programming mode page EAr field EXPE 5 TTHY Hard tare attached sensors equivalent to programming mode page EAr field EXPE h Summary Tell the DS 3000 how to handle user tare requests both front panel and remote 11 7 SST I Function Read Sensors internal status code Keystrokes Th
35. lly I or not included blank SEn 4H Sor Include Sensor 4 in Sum with other sensors S individually P or not included blank duUrAtn 09 00 Active trigger Duration interval seconds or continuous contin Setting the duration to 0 causes the DS 3000 to be in continuous mode output is active whenever the threshold conditions are satisfied Summary Contact output 2 can be used to control external equipment attached by means of the provided removable wiring connector Contact terminals are marked COM common NO normally open and NC normally closed The contact terminal labels indicate the inactive contact state le NO contacts are OPEN when inactive but CLOSED when active Both NO or NC contacts are referenced to the COM or common terminal Outputs may be pulsed by selection of appropriate momentary contact duration or continuous More details and examples programming these entries will be given in the programming examples section following later in this document 8 2 6 Power Options Menu Function Power Save and Power Control Options Keystrokes Press menu until Po Er is displayed then up or down to reach each entry Eott Time Out interval value Press enter and up down to select power save duration in minutes Default is 0 for continuous operation On expiration of the time out interval the DS 3000 goes to sleep shuts down attached sensors and g
36. made in the internal programming menu are retained after power off so your current settings may differ from the default values You may reset the current DS 3000 settings to the factory default using the menu entry FACtor under the oft ionS programming page documented later in this document 6 1 Entering programming mode from run mode 1 Press menu Display will show EntEr PASS Display will show a numeric entry field 000000 Press enter to directly return to run mode or Press up or down to select the desired password value default is 02003 1 Press and hold enter until the first programming page d5P_AY appears NS a DN Now pressing menu will step through the available programming mode pages 6 2 Entering run mode from programming mode 1 Press shift until Un is displayed 2 Press and hold enter 3 Display will return to run mode and display the load using the current display settings 6 3 Modifying a Programmed Value 1 In programming mode Press menu until the desired programming page is displayed 2 Press up or down to select the sub menu entry Press enter to edit the currently displayed sub menu field a If the field is a logical field up or down will toggle through the available values b If the field is a numeric data entry field up or down will increment or decrement the currently highlighted digit Press menu to step through all numeric digits setting each one in turn until the desired value is displayed
37. monitoring capability also come standard This chapter introduces how to connect your PC to the DS 3000 and subsequent chapters will document the remote capabilities The DS 3000U is accessed by your host PC using a standard virtual com port mechanism provided by your OS Either your custom application or the LoadVUE software application available from LoadStar Sensors uses this same interface In this chapter we use as example the most common computer configuration a windows based PC OS running hyper terminal such is found in all Windows XP PCs If this does not describe your PC an equivalent product may be available for your operating system The approach demonstrated here may be easily adapted to other terminal programs and other Operating Systems The same data can be sent and received to the DS 3000 whether the application is a terminal program or any other user written programs in high level programming languages or in virtualized programming applications such as LabView MATLAB or EXCEL VBA 10 1 Installing Virtual com port drivers The DS 3000 is attached to your PC using a standard USB Type A to USB Type B cable This cable is included in your DS 3000 package Once connected to the USB port on your PC you may find your PC requires additional drivers We recommend you download the latest driver version for your particular operating system They can be found at http www ftdichip com Drivers VCP htm additional information on in
38. nd the DS 3000 mechanical specifications 4 2 DS 3000 Mechanical Dimensions cccccceeeeceeeeeeceeeeeeeeeeeeeeeaeeceeeeeeaeeeensneeeeeeeenaees 12 7 Find the DS 3000 power requirements MODULE FEATURES hunnen 9 1 8 Review detailed DS 3000 specifications 12 DS 3000 TECHNICAL SPECIFICATIONS irritera notan aeradenn iain idie eine iieri 47 Loadstar Sensors Inc Page 7 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 2 INTRODUCTION The Loadstar Sensors DS 3000 portable display provides a convenient method of monitoring loads on up to four Loadstar load cells simultaneously The DS 3000 device supports the complete range of Loadstar s iLoad USB load cell line the iLoad Digital USB iLoad Pro Digital USB iLoad TR Digital load cells the iLoad Mini when paired with the DQ 1000U Frequency to USB converter and the complete FlexiSensor line when paired with the CS2000 CS4000 The 6 digit LED displays the loading of one to four connected sensors in any combination A front panel push button or an external input can be used to simultaneously tare all connected sensors Other front panel push buttons change displayed units Newton Pound Kilogram and display precision Combinations of push buttons access the advanced settings and programming menus where many advanced features and PLC like programmable functions are accessible for advanced users Two programmable relay outputs can be synchronized to an externa
39. neaeaaeeeeeeeeseeesseeeaaeeeeneeeeeegs 28 9 1 3 Programming Summary c ccccccceeeeeeceeeeeeeceeeeeeeeeceeeecaeeeeseeeeeeeeeseeeesesseeeeeeetaeeeeees 29 9 1 4 Programming the DS 3000 ceeccccceeeeeceeeeeeeeceeeeeeaeeeeeeeseaeeeeesaeeeeeesesaeeeeteneaeeess 29 9 2 Empty Tank Warning ccccccceceeeceeeeeeeenneeeeeeeeeeeeeeeeaaeeeeeeeeeeeeesenaaaaeeeeeeeeeeeeseenaaeeeeeeees 30 9 2 1 Application Requirements rrnnnvrrnnnnnnvrnnnnnnnnvrrnnnnnnnrnnnnnnnnnrrnnnnnsernnnnnnnvrrnnnnsssrnneennnn 30 9 2 2 Implementation Details rrrrrnnnnvvonornnnnnnnnnnnnnvnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnnnnnennnnnnnnnn 31 9 2 3 Programming the DS 3000 rrrrnnrnnvrrnrrnnnrnnrnrrnnnnnrrnnnnnnrrrrnnnnnnrnnnnnerrnnnnnnnnrrnnnnnnnnnnn 31 Loadstar Sensors Inc Page 5 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 9 3 Go NoGo Acceptable Weight Limit Test cccecceceeeecceeeeeeeeeeeeeeeeeeeeeeeeneeeeeeeneeetees 32 9 3 1 Application Requirements ronnnnnonnnnonnnnnnnvnnnnnennnnnnnnnnnnnnnnnnennnennnnennnnnnneennneeennennnnen 33 9 3 2 Implementation Detail Si2 22 icce chi nn chbaccshadiasgeti eed shecedbadsaeiadeecsssde bd md add dn se en 33 9 3 3 Programming the DS 3000 rrrrnnrnnrrnnrrnnrrnnrnrrnnnnnnrnnnnnnrnrrnnnnnnrnnnnnnrrnnnnnnnnrrnnnnnnnnenn 33 9 4 Automated Fertilizer Bag Fill Dispense system rrrnnnnrrrnnnnnnnnnnnnnnnnrrrnnnnnnrrnnnnrrnnvnnnnnnnrr 34 9 4 1 Applic
40. nnnnnrrnnnnvrnnnnrnnenesrennnnrrrnnrrenessee 22 8 1 4 Change Display Precision Mode cccceeccceeeeeeeeeeeeeeeeeeeeceeeeecesseeeeeesaeeeeesnenaeeess 22 8 2 Programming Mode Command ccccccecceeeeeeeeeeeeeeceeeeeseeeeeceeeeeeeeeeeeenaeeeeeeneeeeeeeeaees 23 8 2 1 Programming Command SUMMAL c cccceeeceeceeeeeeeeeeeeeeeeeeeeaeaeeeesenaeeeeesneaeeess 23 8 2 2 Display Options Menu ccceeccececeeeeceeeeeeeeeeeceeeeneeeeeeaeeeeseaeeceeeeseaeeeessneeeeeetenaees 23 8 2 3 Tare Options Menu i ihmsethsdmetetessmatd eisean iaei aa EEE E E ER E REEE ERRIRE SEES 24 8 2 4 Relay Output 1 Menu c ccceeecceceeeeeeceeceeeeeeeeeeecaaeeeeeeeaeeeeecaeeceeeeeeeeeeseeneeeetseneaees 24 8 2 5 Relay Output 2 Menu ccceeeececeeeeceececeeeeceeeeseaaaeeeeeeaaeeeeeeaeeceeeeeeaeeeeeeneeeeeeeneaees 25 8 2 6 Power Options Menu ins sasmmeri raasderadenent lendasaeegadlsetageascerspsagaeas canpadesstlaaatnntgelianandees 26 8 2 7 Option Menu eesin onnee aeaea aeaa aaa aa Ea EEEa E aaa a E aAa a SAREE 27 8 2 8 Run 27 9 DS 3000U SYSTEM PROGRAMMING EXAMPLEG 2 cceeeeceeeeeeeeeceeeeeeeeeeeeeeeeeeeeeeeaees 28 91 Tank Fill Controller riiin percinta aeaaaee aaaea E aa EE lds AR REEE Ea 28 9 1 1 Application Requirements rnnnvvrnnnnnnvrnnnnnnnnrrrnnnnnnnrnnnnennnnrrnnnnnsrrnnnennnnvrrnnnesssenneennnn 28 9 1 2 Implementation Details eceeeecceccsceeeeeeeeseeeeeeeeeceeeeeees
41. ntered selected value i e ENTER e In enter password mode if the incorrect password is entered this key will automatically return you to run mode e The ENTER TARE ALL key will be abbreviated enter in the remainder of this document UP UNITS up e In run mode this pushbutton cycles through and selects the displayed units You may select from US pounds Lb Kilograms Kg or Newtons N e In programming mode this button steps UP in the currently selected menu tree or increments the current highlighted digit in a numeric entry field e The UP UNITS key will be abbreviated up in the remainder of this document DOWN FUNCTION down e In run mode this pushbutton selects the position of the decimal point Loadstar Sensors Inc Page 14 48 033 01419 Rev 4 DS 3000U DS3000 User Guide e In programming mode this button steps DOWN FUNCTION in the currently selected menu tree or decrements the current highlighted digit in a numeric entry field e The DOWN FUNCTION key will be abbreviated down in the remainder of this document 5 2 Getting Started Figure 8 What you need to get started with the DS 3000 If you plan to communicate with the DS 3000U from a PC and or use LoadVUE software with it install the PC drivers and or LoadVUE on the PC first Next plug in the provided power adapter into the DS3000 top left If you wish to communicate with a host PC or use LoadVUE plug in the provided USB Hos
42. o the tank 9 1 1 Application Requirements 1 4x sensors each with 10000 Lb load capacity each 40000 Lb total scale load capacity 2 Typical empty tank dead weight with no water or minerals present 1200 Lbs 3 Acceptable tank trigger filled with water weight 3500 Ibs 4 Let Sensor 1 Sensor 4 correspond to the four load cells each corresponds to one DS 3000 module input 9 1 2 Implementation Details 1 Connect the water control valve to Output 1 so when the relay is active water flows into the tank Connect each of the four load cells to consecutive inputs on the DS 3000 Connect the process controller start contacts to the remote input on the DS 3000 Assume units of pounds Lbs make sure the front panel LED is illuminated in the Lbs position Loadstar Sensors Inc Page 28 48 033 01419 Rev 4 DS 3000U DS3000 User Guide START PROCESS1 2 _ REMOTE a INPUT WATER VALVE een OUTPUT 1 POV gt NO COM POWER INPUT hb OUTPUT 2 COM i DS 3000 Figure 9 Wiring for Program Example 1 9 1 3 Programming Summary 1 Configure the DS 3000 remote input to reset and tare the displayed value at program start Reset means output 1 will be reset to it s default state and will remain there until triggered Tare means to automatically zero the results at whatever the current load value is Set the threshold
43. o toggle to the numeric entry field 13 Press up and down pushbuttons to increment and decrement the currently selected flashing digit Press the menu button to highlight the next digit Repeat as necessary until your desired password is displayed onscreen 14 Press enter when you are done The new password is automatically updated 15 Now exit programming mode Press mode until the Un entry 16 Then press enter to return to run mode Loadstar Sensors Inc Page 19 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 7 11 What if I ve lost the password How can I get into program mode 1 Unfortunately you can t If you lose the password you have to send the unit back to Loadstar Sensors so we can reset the unit for you 7 12 How do I reset the unit to factory defaults Press and hold menu until EnkEr PASS and 500000 appear on the display Press the up or down keys to select the programming mode password default is 0000 1 Press enter You are now in programming mode at the d5P A4 prompt Press mode until you reach the ofk ian menu Press down to the FActar entry Press enter and once all the LED decimal points illuminate the unit will be reset back to factory defaults NOTE All programming and other customizations WILL BE LOST Now exit programming mode Press mode until the Un entry Then press enter to return to run mode 7 13 Is there an easy way to see what is currently programmed o
44. oduct off of the assembly line Like all manufacturing environments the scale is subject to constant weight fluctuations due to temperature changes material buildup etc And should be tared aka reset to zero as frequently as possible Ideally the system will provide a remote tare signal when the scale is unloaded before every product test and then will provide a remote load sense signal when the scale is appropriately loaded ready for test Loadstar Sensors Inc Page 32 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 9 3 1 Application Requirements 1 1 sensor each with 100 Lb load capacity Sensor plugged into port 1 2 Remote input used to enable testing product weight provided by system 3 Remote input used to enable scale tare provided by system 4 Nominal product weight assumption for this example 10 0 2 Lbs 9 3 2 Implementation Details 1 Connect the outputs as in Figure 11 Schematic for Program Example 3 2 When the weight is above 10 2 Ibs or below 9 8 Ibs activate the output deactivate otherwise 3 Lets use units of Pounds so press the up key until the pounds lamp is illuminated REMOTE LOAD SENSE START PROCESS REMOTE INPUT MECH FLAPPER AA OUTPUT 1 NO OUTPUT 2 POWER INPUT COM Figure 11 Schematic for Program Example 3 9 3 3 Programming the DS 3000 1 Press and hold menu until EntEr PASS and 000000 appear on the display 2 Press the up o
45. oes to a lower power operational mode The unit can be awakened by pressing any front panel key bAt Press enter to toggle between bAE En enabled and bft blank or disabled If you have a battery option installed in your DS 3000U the battery is set to enabled at the factory You should only use this option if you want to disable battery power backup features or remove disable the battery Please note that if you do not have the battery option installed this menu item has no effect regardless of setting 5152 53 or 54 Press enter to toggle between on and of F on means the ne sensor port is powered and off means the sensor port is unpowered The factory default is to power all sensors plugged in to the DS 3000U Summary Adjust the power save options Loadstar Sensors Inc Page 26 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 8 2 7 Option Menu Function Miscellaneous Options Menu Keystrokes Press menu until oPt on is displayed then up and down to select the desired field Select brightness of onboard LED display Range is 10 to 128 default value is 64 128 is maximum brightness and maximum power consumption 10 is minimum brightness Set function of remote tare trigger contacts Use ENTER to toggle among t r and b The blank setting is not to be used and may lead to unexpected results These options cause the following behavior upon closing the remote
46. r 7 14 How do I check my programming The easiest way to do this is using the REMOTE interface See chapters Installing Virtual com port drivers and Remotely Programming the DS 3000 Once you are connected to the DS 3000 using Hyperterminal or another terminal program from your host PC you may issue the command settings lt enter gt Loadstar Sensors Inc Page 20 48 033 01419 Rev 4 DS 3000U DS3000 User Guide DS 3000 HyperTerminal File Edit View Call Transfer Help Da 48 D A A DS3000 MLB DS3 Settings V3 5 SS SSL DISPLAY 1 0n 2 0n 3 0n 4 0n Tare Type Soft Units MLB LED Brightness 180 125 64 Relay 1 Trigger Point 1 ra 0 200000000E1 Trigger Point 2 rb 9 4000000 GE0 Using Sensors 1 sum 2 sum 3 sum 4 sum Duration 0 100000008E 2 seconds continous Relay 2 Trigger Point l ra 0E9 Trigger Point 2 rb 9 0E0 Using Sensors 1 2 3 S Duration 0 100000008E 2 seconds continous Sleep Time Out seconds disabled External Tare bot Connected 0 19 13 Auto detect 9600 8 N 1 SCROLL CAPS NUM Capture Print echo Which outputs all of your current programmed settings Loadstar Sensors Inc Page 21 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 8 COMMAND REFERENCE 8 1 Run Mode Command Descriptions Run mode is when the DS 3000 is currently displaying load on the display and is not awaiting any user input This is the default state All
47. r down keys to select the programming mode password default is 20000 1 Loadstar Sensors Inc Page 33 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 10 11 12 13 14 15 16 17 Press enter You are now in programming mode at the d5P AY prompt Press mode until you reach the rELAY menu Press down to the Er3r I entry Press enter and a numeric entry field will appear Enter 10 2 Lbs Press menu until the digit corresponding to the 2 is highlighted then press up and down to set the digit to 2 Press mode again to highlight each digit in turn then up and down to set each one to the correct value Press enter when you are complete Press down to get to the next programming entry Select Pnt IEA for Prt I using the enter key to select This will activate the output when above this threshold Press down to Er9r 2 press enter and a new numeric field appears Enter 9 8 Lbs Press enter when completed Select Pntctb for Pate using the enter key to select This will activate the output when it drops below this threshold PIET Press down to 5En I corresponding to sensor 1 Press enter until is displayed This means that the trigger condition will only look at sensor 1 Finally press down to dir itn press enter and make sure it is set to cont in Press enter to leave this field Press menu till oPt ion page is displayed Press down to r3t press enter until E 9t t is displayed This enable
48. rrnnnnnnrnn renere nnnnnnrrnnnnnnennnn 14 5 1 Quick Operation and Programming Overview rrrrrnnnrnnrrnnnnnnnnrnnnnnnnrnnnnnnrrnnnnnnrrnnnnnnnennn 14 52 Getting Started sceindis niopen arp iaa aar a Ea p Eoria Oane a Reisa aiina iS 15 6 RUNNING OR PROGRAMMING 00 cccccceeeececeeeeceeeeeeeeeeeeeeceeeeeeceeeaeeeeeeeeeeeeneeaeeeeeeeieeeeseeees 16 6 1 Entering programming mode from run MOde cccceeeeeeeceeeeeeeeeeeeeeeeeeeeeesneeetessaeeees 16 6 2 Entering run mode from programming Mode ccceeeececeeeeeeeeeeeeeneeeeeeeesseeeesenneees 16 6 3 Modifying a Programmed Value rnnnnnnnnnnnnnnnnnrnnnnnnnrnnnnnnnnrrnnnnnnrnnnnnnnrrnnnnnnenrnnnnnerrnnnnnnen 16 7 QUICK PROGRAMMING HOW TO TIPS rrrrnnrrnrnnnrnnrrnnrrnrrnnnrrnnnnnnrrrnnnnnnrrnnnnnnenrrnnnnenrnnnnnenn 17 7 1 How to change the displayed decimal point location rrnnrnrnnnnnnnnnrrrnnnnnnnnnnnnrrnnnnnnnnnner 17 7 2 How to reset or TARE the current displayed value to Zero rnrnnrrnnnrnnnnrnnnrnnnrnnnnnnrnnnnn 17 7 3 How to display the load from only sensors choose rrnnnnnrrnnnnnnrrnrnnnnrnnnnnnnnrrnnnnnnrrnnnn 17 7 4 How do I tare only one connected SCNSOM ccceeeeceeeeeeeeeeeeeeeeeeeeeeeaeeeeeeecaeeeeeeeeeeees 17 7 5 How can I tell which sensors are currently being displayed mrrrnnrnnnrnnvrnnrrnnnnnnrnnnnn 18 7 6 How do I get the firmware version ccecceccceeeeeeceeeeeeeeeeeeeeeaeeesesea
49. run mode keystrokes have an immediate effect on the displayed value 8 1 1 Tare All Sensors Function TARE ALL Keystrokes Press key enter until A r is displayed then release Displayed decimal points correspond to currently active sensors Summary Tare all connected and active sensors simultaneously 8 1 2 Set Displayed Units DISPLAY UNITS Keystrokes Press key up until the desired units LED is illuminated Options are US Pounds Lb Kilograms Kg and Newtons N Summary Display the current load value in the selected units 8 1 3 Enter Programming Mode Function PROGRAM MODE Keystrokes 1 Press menu 2 Display will show EntEr PASS 3 Press up or down to change the value of the currently highlighted digit and menu selects which digit is currently highlighted Enter the correct password value default is 00003 1 4 Press enter 5 Now pressing menu will step through the programming mode pages Summary Switch from run mode to programming mode 8 1 4 Change Display Precision Mode Function SPECIAL FUNCTIONS Keystrokes To Manually select the display precision 1 Press the down button bottom right and holding it down press enter bottom left 2 Now release the down button while continuing to hold down enter 3 While continuing to hold enter press up top right or down bottom right to select your desired decimal point location The current decimal point loca
50. s the remote input to tare the DS 3000 whenever the external contacts are closed Now exit programming mode Press mode until the Un entry Then press enter to return to run mode Once in run mode the program is now operational 9 4 Automated Fertilizer Bag Fill Dispense system At a green marketing company they offer organic fertilizer steer manure and other soil enrichment products for sale by weight In order to minimize costs customers are allowed to bring their own containers which vary in weight and place them on a scale placed under a fill chute After selecting the chosen product they may then purchase a fixed weight amount of the chosen product This application uses a scale platform with a single load sensor and a system contact which provides a contact closure once the customer has paid and placed an appropriate container on the scale The DS 3000 then activates output contact 1 enabling material to pass down the chute until the product weight exceeds a preset value After which the contact opens shutting off the material flow The system is then automatically reset for the next customer after the material and container is removed from the terminal 9 4 1 1 2 3 9 4 2 1 Application Requirements 1 sensor each with 100 Lb load capacity Sensor plugged into port 1 Remote input used to start process Nominal product weight assumption for this example 25 Lbs Implementation Details Connect
51. stalling these drivers can be found at http www ftdichip com Documents InstallGuides htm 10 2 Communicating with the DS 3000 using Hyper terminal HyperTerminal is the most popular terminal program available on Windows PC s since a basic version comes preloaded with Windows XP If you use a different OS many terminal emulator programs are available that support your OS One such program is TeraTerm Pro that can be downloaded as freeware from many locations on the Internet Before connecting your DS 3000 to your PC open device manager and review the ports currently available on your computer Monitors E Network adapters Ports COM amp LPT Bluetooth Communications Port COM25 Bluetooth Communications Port COM4 si Processors After connecting the DS 3000U a new port should appear after the correct drivers have been installed H Network adapters Y Ports COM amp LPT aF Bluetooth Communications Port COM25 Bluetooth Communications Port COM4 aF USB Serial Port COM30 sil Processors Loadstar Sensors Inc Page 37 48 033 01419 Rev 4 DS 3000U DS3000 User Guide This new serial port corresponds to the virtual port of the DS 3000U device Next step open hyper terminal and create a new connection corresponding to your newly attached DS 3000 device gt New Connection HyperTerminal File Edit View Call Transfer Help ose 65 25 8 Connection Description Enter
52. t cable bottom left Attach the other end of USB host cable to your PC Plug in your Loadstar Load cell into any sensor port Press units button top right to display weight in desired units LED will illuminate with the currently displayed units setting Lb Kg N Press fare button bottom left and hold until all decimal points light on display bottom This will tare or Zero all connected sensors at the current loading Set the desired decimal point location While pressing the down button bottom right and holding it press tare bottom left Now release the down button while continuing to hold tare down As you continue to hold down fare press up top right or down bottom right to select location of desired display decimal point For your convenience the current decimal point location is illuminated on the display release tare when the decimal point is in the desired position That s it Your DS 3000 is now displaying the sum of all the loads attached to the input connectors The next section will detail the various advanced features of the DS 3000 accessible through the programming menu s with examples of how to customize settings for your application Loadstar Sensors Inc Page 15 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 6 RUNNING OR PROGRAMMING Default DS 3000 operation is in run mode with all active input sensors summed and the sum displayed onscreen in the selected units Any setting changes
53. the outputs as in Figure 11 Schematic for Program Example 3 Loadstar Sensors Inc Page 34 48 033 01419 Rev 4 DS 3000U DS3000 User Guide POWER INPUT Once the output activates it remains activated until the weight is greater than 25 Ibs After the scale weight drops to less than 1 Ib it is assumed the customer has removed the fertilizer and container and the DS 3000 resets for the next cycle Lets use units of Pounds so press the up key until the pounds lamp is illuminated START PROCESS Figure 12 Schematic for Program Example 4 9 4 3 Programming the DS 3000 1 ROEN 10 11 Press and hold menu until EntEr PASS and 000000 appear on the display Press the up or down keys to select the programming mode password default is 20000 1 Press enter You are now in programming mode at the dSPLAY prompt Press mode until you reach the rELAY I menu Press down to the Er 9r I entry Press enter and a numeric entry field will appear Enter 25 Lbs Press menu until the digit corresponding to the 5 is highlighted then press up and down to set the digit to 5 Press mode again to highlight each digit in turn then up and down to set each one to the correct value Press enter when you are complete Press down to get to the next programming entry Select Pnt i A for Pnt I using the enter key to select This will activate the output when above this threshold Press down to Er9r c press enter and
54. tial damages in connection with the furnishing use or performance of this document or of any information contained herein Should Loadstar Sensors and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms the warranty terms in the separate agreement shall override SAFETY INFORMATION General Do not use this product in any manner not specified by the manufacturer The protective features of this product may be impaired if it is used in a manner not specified in the operating instructions Do not install substitute parts or perform any unauthorized modification to the product Return the product to a Loadstar Sensors office for any required service and repair to ensure that safety features are maintained Instrument Grounding If your product is provided with a grounding type power plug the instrument chassis and cover must be connected to an electrical ground to minimize shock hazard The ground pin must be firmly connected to an electrical ground safety ground terminal at the power outlet Any interruption of the protective grounding conductor or disconnection of the protective earth terminal may cause a shock hazard that could result in personal injury Cleaning Clean the outside of the instrument with a soft lint free slightly dampened cloth Do not use detergent or chemical solvents Doing so may void your warranty Loadstar Sensors Inc Page 2 48 0
55. tion is illuminated on the display while you Loadstar Sensors Inc Page 22 48 033 01419 Rev 4 DS 3000U DS3000 User Guide continue to hold down the enter button 4 Release enter when the decimal point is at the desired position The display will retain this new decimal point selection until changed again or reset to the factory default Summary Manually changing the display precision 8 2 Programming Mode Commands Program mode is when the DS 3000 characteristics responses and outputs are being changed by the user While in programming mode the DS 3000 will not display load from attached sensors it will display a programming menu summarized below awaiting user commands Once done editing you ll need to leave programming mode and go back to run mode to see the results of any programming changes you ve made The unit will not automatically time out and return to run mode once you ve entered programming mode 8 2 1 Programming Command Summary SHE MENU gt ErGk rUn Fee e e ea e ea s e v e Version The actual version of the firmware is displayed e g 3 05 5 5 5 lt UE RE 2 3 4 OlLINN NMOG SL INNA gt 8 2 2 Display Options Menu Function Display Source Select Keystrokes Mode Key menu till dSPLAY is displayed then press up or down buttons to select your desired display mode then press enter to change en
56. to activate relay 1 at below the tare value say 10 Ibs Set the threshold to de activate relay 1 at the desired cut off weight 3500 1200 2300 Ibs Keep the output turned off until the system resets the whole process and water is actually desired to flow into the tank 9 1 4 Programming the DS 3000 REN 6 Press and hold menu until EntEr PASS and 500000 appear on the display Press the up or down keys to select the programming mode password default is 2002 1 Press enter You are now in programming mode at the dSPLAY prompt Press mode until you reach the rELAY I menu Press down to the tr9r I entry Press enter and a numeric entry field will appear Enter the initial trigger weight of 10 Lb Press menu until the digit corresponding to the 1 is highlighted then press up and down to set the digit to 1 Press mode again to highlight each digit in turn then up and down to set each one to the correct value Press enter when you are complete Press down to get to the next programming entry Loadstar Sensors Inc Page 29 48 033 01419 Rev 4 DS 3000U DS3000 User Guide 7 Select Prt irb for Prt I using the enter key to select 8 Press down to tr95r 2 press enter and a new numeric field appears Enter 2300 Lbs Press enter when completed 9 Select PrtcrA for Pate using the enter key to select This will reset the output and terminate the sequence every time the weight rises above 2300 Lbs Th
57. to the desired value These parameters affect Relay Output 2 only Relay 1 and Relay 2 are independent and are programmed separately kr r First trigger action threshold Select enter to enter the numeric entry field up and down changes the value of the currently highlighted digit and menu changes the currently highlighted digit Press enter when finished Prt IEA Activate output 2 above this value ie Trigger Above Pnt itb Activate output 2 below this value ie Trigger Below me Prt I A Reset output 2 above this value ie Reset Above Prt irb Reset output 2 below this value ie Reset Below tr9r 2 Second hysteresis action threshold Select enter to enter the numeric entry field up and down changes the value of the currently highlighted digit and menu changes the currently highlighted digit Press enter when finished Loadstar Sensors Inc Page 25 48 033 01419 Rev 4 DS 3000U DS3000 User Guide Poke Prt tA Activate output 2 above this point Prt tb Active output 2 below this point Prt rA Reset output 2 above this point Prt rb Reset output 2 below this point SEn I 5 Include Sensor 1 in Sum with other sensors S individually P or not included blank SEn Sort Include Sensor 2 in Sum with other sensors S individually I or not included blank SEn3 Sor Include Sensor 3 in Sum with other sensors S individua
58. uipment and improve the environmental performance of everything involved in the life cycle of electrical and electronic equipment This is translated into the following requirements Producers manufacturers or importers of electrical and electronic equipment will be required to register in their countries Private households will be able to return their WEEE to collection facilities free of charge and producers will be responsible for financing these facilities Producers will be required to achieve a series of demanding recycling and recovery targets Wheeled bin emblem Producers will be required to mark their products with the crossed out wheeled bin This symbol indicates that the equipment carrying this mark must NOT be thrown into general waste but should be collected separately and properly processed under local regulations The WEEE directive has been transposed into each EU member state s legislation and so the exact timing and details will vary slightly from country to country but the above principles will apply In particular the arrangements for the separate collection of WEEE will vary in each country but might include for example public collection points retailers take back schemes collection from households etc The Directive encourages reuse recycling and other forms of recovery in order to prevent WEEE Users of electrical and electronic equipment in the E U can therefore play an important role in r
59. view All programming is accomplished using four front panel pushbuttons Each front panel pushbutton has two functions The immediate or run mode function that occurs when you press the button while load is displayed and the alternate shifted function which occurs while in programming mode In the description which follows no distinction is made between shifted non shifted functions All buttons are referred to by their common run mode label indicated in italicized bold text The function of each button is described below With any key press there will be a delay before response Press and hold the desired button until the function occurs This feature helps to eliminate false key presses capri menu When in run or normal operation mode this pushbutton selects programming mode e When in programming mode this button steps through the high level menu columns e When in a programming mode sub entry pressing this button will return to the top most menu item e When in a programming mode numeric data entry field this button increments to the next significant digit Numeric fields are typically edited one digit at a time e The SHIFT MENU key will be abbreviated menu in the remainder of this document ALL enter In run mode this push button automatically tares all active sensors even if the display is set to display something different e In programming mode this button accepts the currently e
60. vrrrnrrrnrrrnrrrnvrrnnrrrnnenn 43 11 11RNTPxT amp 2 Future Command Not yet implemented rernnrnnronrrnrnrrrrrnnnrrnnnnrnnnnrnnnnn 43 11 12RnSx Future Command Not yet implemented rrrnrrrnvrrnvrrnvrrnvrrnvrrnvrrrnrrrnvrrnvnrnnenn 44 11 13RnD Future Command Not yet Implemented rrnnnrrnnnnnrnnrnrnnrnnnrnrnnnnrrnnnrrnnnnrnnnnr 44 11 14ASx RSx amp Future Command Not yet implemented rsrrrnrrrnvrrnvrrnvrrvrrrnnrrnvrrnnenn 44 AA AIO DB ESE de 45 11 16UNIT Future Command Not yet implemented ccccceeeeeeeeeeceeeeeeeeseeteseeeenees 45 11 17SETTINGS Porse E E 45 12 DS 3000 TECHNICAL SPECIFICATIONS c cccecceeeeeeeecceeeeeeeeeeeeeeaeeeeseneeseeeeesneeesseaeeees 47 List of figures Figure 1 DS 3000 Top View User Interface cccccceceecceeeeeneeceeeeeeeeeeeeeeaeeeeteneeeesenneaeeess 10 Figure 2 Side View Input Sensor Connectors cccccccccceeeeceeeeeeeeeeeeeeeeeaeeeeeeeaeeeeeeseaeeees 10 Figure 3 End View Power and USB Host Connections cccccccceeeeceeeeeeeeeeeeeeeseeeeeees 11 Figure 4 End View Wiring Adapter Socket ccccecccceeeneeceeeeeeeeeeeeeeaeeeseeeeseeeeeneaeeees 12 Figure 5 DS 3000 Top View Includes optional mounting base rrrrrrrrrnnnnrrnnrrnrnnnnnnnrnn 12 Figure 6 DS 3000U Mechanical Host End View ccccecceceeeeeeeeeeeeeeeaeeeeeseaseeeesseaneess 13 F