Home

GT10-LDR Memory loader User`s Manual

image

Contents

1. Password is set in the project data OS installation screen is not active 1 An error message appears on the GOT screen Apply remedies according to the display Refer to the Chapter 12 Troubleshooting for details on handling errors 6 Switch operation specification Switch Name RD WR selection switch Data selection switch Write protection switch ENT key Specifications Switch to select read write direction RD The data is read out from the GOT to the memory loader WR The data is written from the memory loader to the GOT Switch to select the data to be transferred e When reading out the data from the GOT to the memory loader PROJECT OS The standard monitor OS communication driver project data and resource data are read out from the GOT to the memory loader PROJECT The project data and resource data are read out from the GOT to the memory loader e When writing the data from the memory loader to the GOT PROJECT OS The standard monitor OS font data communication driver and project data are written from the memory loader to the GOT PROJECT The project data is written from the memory loader to the GOT Switch to prevent the memory loader from being written to the data ON The data cannot be written neither from the GOT or a PC GT Designer2 GT Designer3 to the memory loader OFF The data can be written from the GOT or a PC GT Designer2 GT Designer3 to the memory loader Switch to det
2. 1 Connect the memory loader to the GOT and turn ON the GOT 2 Set the Data selection switch to PROJECT and the RD WR selection switch to WR and select the data to be transferred and transfer direction 3 Press the ENT key to determine the data to be transferred and transfer direction SET RUN LED will be orange If the next operation is not performed within 30 seconds after the ENT key is pressed SET RUN LED will be unlit and the operations that have been made will be canceled When the Data selection switch or the RD WR selection switch is operated after the data to be transferred and the transfer direction are determined the operations that have been made will be canceled 4 Press the ENT key again to start the transfer SET RUN LED will be green flashing 5 Turn OFF the GOT and remove the memory loader after the transfer is completed SET RUN LED will be green flashing Refer to the Chapter 12 Troubleshooting for details on handling errors during transferring 11 To read out the data from the GOT to the Memory loader The standard monitor OS communication driver project data and resource data are read out from the GOT to the memory loader The operation procedure is described below 11 1 When the Data selection switch is PROJECT OS y gga Project data So Aor a Communication driver Standard monitor OS Resource data GT1020 GT1030 Memory loader 1 Turn OFF the
3. Inte When the password does not match an error message is displayed If button is touch it returns to the password input screen again PASSHIORD 3 INCORRECT After all data in the memory loader is deleted only the project data and resource data in the GOT are read out to the memory loader 4 It takes longer time to transfer the font data than to transfer the standard monitor OS and communication driver It takes approximately 1 minute and 45 seconds to transfer Standard monitor OS Communication driver It takes approximately 8 minutes to transfer Standard monitor OS Communication driver Font data Japanese supporting Europe is installed in the GT10 before shipment from the factory It is not necessary to transfer the font data when the used font is not changed 7 3 Error display function If an error occurs between the GOT and the memory loader during the transfer an error message will appear on the GOT screen Apply remedies according to the display i Chapter 12 Troubleshooting Turning OFF and ON the power or touching the screen will close the error message screen When this function is used Ver 01 08 00 or later of the standard monitor OS of the GT10 is required rs ST TO LDR Error ESC Wrong GOT model is connected Error message on the GOT A 8 Installation of Driver Setting Software When the communication between a PC GT Designer
4. secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN
5. 9 Check the GOT type to which the memory loader is connected The data to be transferred is broken or the major version of the standard monitor OS is different from that of the project data e Write the standard monitor OS communication driver and project data from GT Designer2 or GT Designer3 to the Red light memory loader again and then transfer them to the GOT again e Set the Data selection switch to PROJECT OS and read out all data from the GOT to the memory loader and then transfer them to the GOT again Communication error occurs between the GOT and the memory f loader Ped Mashing e Check the connection with the communication cable e Check that power supply is stable lighting of POWER LED Red Green Password is set in the project data e Reset the password with the numeric keypad on the GOT Grandes OS installation screen is not active a Install the data after the OS installation screen is displayed on the GOT This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage
6. PC PROJECT 3 Memory loader gt OS All data in the memory loader is written to the GOT GOT PROJECT Only the project data in the memory loader is written to the GOT PROJECT os After all data in the memory loader is deleted all data in the GOT is read out to the memory loader 4 GOT gt Memory loader PROJECT 14 Ver 01 08 00 or later of the standard monitor OS of the GT10 is applicable 2 Wer 01 11 00 or later of the standard monitor OS of the GT10 is applicable 3 Ver 2 91V or later of GT Designer2 or Ver 1 01B or later of GT Designer3 are applicable 7 2 Password reset function on the GOT When reading out the project data from the memory loader if the password is set in the project data password entry screen will appear on the GOT After entering the password password is reset by pressing the ENT key on the screen The data will be transferred from the GOT to the memory loader The operation procedure is described below When this function is used Ver 01 08 00 or later of the standard monitor OS of the GT10 is required 1 When the upload is started password entry screen will appear on the GOT Touch the INPUT key GTIC LDR Info Password required INPUT 2 After inputting password touch the ENT key 3 When the password matches a message notifying Password correct is display Touch the button to close the screen GT 10 LOR ESC Password correct
7. Ver 1 01B or later The project data and resource data are read out from the memory loader to a PC GT Designer2 GT Designer3 The operation procedure is described below Project data Resource data Memory loader GT Designer2 GT Designer3 1 Connect a PC GT Designer2 GT Designer3 to the memory loader with USB cable supplied 2 Select the data to be uploaded in a PC GT Designer2 GT Designer3 and read it out from the memory loader Refer to the following manual for details about operating instructions of GT Designer2 or GT Designer3 CF GT Designer2 Version Fj Basic Operation Data Transfer Manual GT Designer3 Version O Screen Design Manual Fundamentals 10 To write the data from the Memory loader to the GOT The standard monitor OS communication driver font data and project data are written from the memory loader to the GOT The operation procedure is described below 10 1 When the Data selection switch is PROJECT OS Standard monitor OS Communication driver Font data Project data GT1020 GT1030 Memory loader 1 Connect the memory loader to the GOT 2 Turn ON the GOT by pressing the lower right corner of the GOT The GOT startups with OS installation screen The OS can be transferred from GT Designer2 Version2 or GT Designer3 Version Fj without displaying the OS installation screen depending on the combination of the GOT and the standard monitor OS Refer t
8. data to be transferred and transfer direction SET RUN LED will be orange If the next operation is not performed within 30 seconds after the ENT key is pressed SET RUN LED will be unlit and the operations that have been made will be canceled When the Data selection switch or the RD WR selection switch is operated after the data to be transferred and the transfer direction are determined the operations that have been made will be canceled 5 Press the ENT key again to start the transfer SET RUN LED will be green flashing 6 Turn OFF the GOT and remove the memory loader after the transfer is completed SET RUN LED will be green flashing Refer to the Chapter 12 Troubleshooting for details on handling errors during transferring 12 Troubleshooting 12 1 GOT error message When communication between the GOT and the memory loader does not work check the following contents depending on the GOT error messages GOT error message Remedy Write protection switch is ON Write protection switch ON Turn OFF the Write protection switch The GOT type that is set in the data to be transferred differs Wrong GOT model is from that of the GOT to which the data is transferred connected Check the GOT type to which the memory loader is connected The data to be transferred is broken or the major version of the standard monitor OS is different from that of the project data e Write the standard monitor OS comm
9. standard Details Port No Baudrate 115200 v bps Test 8 4 Setting GT Designer3 Click Communication Communicate with GT10 LDR to display the communicate with GT10 LDR screen Click the Communication Configuration tab to display the communication configuration dialog Select the same COM number as the COM number of the personal computer when the setting communication port screen appears Click OK Communication Configuration lt Note gt GT10 LDR has USB RAS232 converter built in Hence use the following RS232 setting for the communication configuration Port No Baud Rate 115200 v bps 9 Transfer procedures between a PC and the Memory loader 9 1 To write the data from a PC GT Designer2 Ver 2 77F or later GT Designer3 Ver 1 01B or later to the memory loader The standard monitor OS communication driver font data and project data are written from a PC GT Designer2 GT Designer3 to the memory loader The operation procedure is described below Standard monitor OS Communication driver Font data Project data Memory loader GT Designer2 GT Designer3 1 Turn OFF the Write protection switch 2 Connect a PC GT Designer2 GT Designer3 to the memory loader with USB cable supplied 3 Write the data from a PC GT Designer2 GT Designer3 to the memory loader Refer to the following manual for details about operating instructions of GT Designer2 or GT De
10. the local Mitsubishi Electric sales site a J 4 9 Operating ambient humidity 10 to 90 RH non condensing Before using this product please read this manual and the relevant manuals A j dM l introduced in this manual carefully and pay full attention to safety to handle the ssociate anuals Storage ambient humidity 10 to 90 RH non condensing product correctly The following manuals are relevant to this product When these loose manuals are The precautions given in this manual are concerned with this product required please consult with our local distributor L Frequency Acceleration Half amplitude Sweep Count ee the safety precautions are ranked as WARNING and Nant EE Under intenniitent 5 to 9Hz Po 85mm Manual name Contents Number Vibration resistance B3502 and vibration 9 to 150Hz Bme fe iOtmes SAG Indicates that incorrect handling may cause hazardous Model Code IEC61131 2 oH 7 and Z directions N WARNING conditions resulting in death or severe injury Describes the GT10 hardware relevant Under continuous Stoo _ _ 5m P r content such as part names external vibration 9 to 150Hz 49mis f Indicates that incorrect handling may cause hazardous dimensions mounting power supply JY997D24701 CAUTION conditions resulting in medium or slight personal injury GT10 User s Manual Wiring specifications and introduction to 09R819 Shock resistance Conforms to JIS B3502 IEC 61131 2 147 m s2 3 times each in X Y and Z
11. 2 Ver 2 77F or later GT Designer3 Ver 1 01B or later and the memory loader is performed driver installation communication port setting is required 8 1 Driver installation When the communication between a PC GT Designer2 GT Designer3 and the memory loader is performed driver installation is required Refer to the following manual for details about driver installation en GT Designer2 Version O Basic Operation Data Transfer Manual GT Designer3 Version Screen Design Manual Fundamentals 8 2 Confirmation of communication port Windows XP example follows e In Windows XP click Start Settings Control Panel Performance and Maintenance System Hardware Device Manager D and the window below will be displayed Please confirm the COM number to which the USB driver is allocated COM and LPT e If using Windows 98 Windows 98SE Windows Millennium Edition or Windows 2000 A screen that is equivalent to the one below is displayed by clicking My Computer Control Panel System Device Manager in the menu of the personal computer e If using Windows Vista A screen that is equivalent to the one below is displayed by clicking Start Control Panel Device Manager in the menu of the personal computer HHE E IDE ATA ATAPI controllers i Other devices a7 Ports COM amp LPT a Printer Port LPT1 System devices Universal Serial B
12. 77F or later GT Designer3 Ver 1 01B or later and GT10 LDR GT1020 GT1030 USB connecting cable supplied z GT Designer2 Ver 2 77F or later GT Designer3 Ver 1 01B or later When GT10 LDR is connected to a PC via the USB hub the power supply of the USB hub must be supplied by the AC adopter of the USB hub GT10 LDR connected to the USB hub may not work properly depending on the PC environment In the case connect the GT10 LDR directly to the USB port on the PC 2 Specifications 2 1 General Specifications Item Operating ambient temperature Storage ambient temperature Operating ambient humidity Storage ambient humidity Vibration resistance Shock resistance Operating atmosphere Operating altitude Overvoltage category s Pollution degree 4 Cooling method Specifications 0 to 40 C 20 to 60 C 10 to 90 RH non condensing 10 to 90 RH non condensing a eey eea e a sero awe Conforms to JIS B3502 IEC 61131 2 147 m s2 3 times each in X Y and Z directions Sweep Count Under intermittent Conforms to JIS vibration B3502 and IEC61131 2 Under continuous vibration Must be free of lamp black corrosive gas flammable gas or excessive amount of electro conductive dust particles and must be no direct sunlight Same as for saving 2000 m 6562 ft max Il or less 2 or less Self coo
13. GT10 is required rs ST TO LDR Error ESC Wrong GOT model is connected Error message on the GOT A 8 Installation of Driver Setting Software When the communication between a PC GT Designer2 Ver 2 77F or later GT Designer3 Ver 1 01B or later and the memory loader is performed driver installation communication port setting is required 8 1 Driver installation When the communication between a PC GT Designer2 GT Designer3 and the memory loader is performed driver installation is required Refer to the following manual for details about driver installation en GT Designer2 Version O Basic Operation Data Transfer Manual GT Designer3 Version Screen Design Manual Fundamentals 8 2 Confirmation of communication port Windows XP example follows e In Windows XP click Start Settings Control Panel Performance and Maintenance System Hardware Device Manager D and the window below will be displayed Please confirm the COM number to which the USB driver is allocated COM and LPT e If using Windows 98 Windows 98SE Windows Millennium Edition or Windows 2000 A screen that is equivalent to the one below is displayed by clicking My Computer Control Panel System Device Manager in the menu of the personal computer e If using Windows Vista A screen that is equivalent to the one below is displayed b
14. JY997D29501F MITSUBISHI ELECTRIC GT10 LDR Memory loader User s Manual Manual Number JY997D29501F GRAPHIC OPERATION TERMINAL GOTicoo This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective April 2015 Specifications are subject to change without notice 2007 MITSUBISHI ELECTRIC CORPORATION Safety Precaution Read these precautions before using Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as WARNING and CAUTION WARNING Indicates that incorrect handling may cause hazardous conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous conditions resulting in medium or slight personal inju
15. LDR Info Password required INPUT 2 After inputting password touch the ENT key 3 When the password matches a message notifying Password correct is display Touch the button to close the screen GTIC LDR Into JESC Password correct When the password does not match an error message is displayed If button is touch it returns to the password input screen again PASSHIORD 3 INCORRECT After all data in the memory loader is deleted only the project data and resource data in the GOT are read out to the memory loader 4 It takes longer time to transfer the font data than to transfer the standard monitor OS and communication driver It takes approximately 1 minute and 45 seconds to transfer Standard monitor OS Communication driver It takes approximately 8 minutes to transfer Standard monitor OS Communication driver Font data Japanese supporting Europe is installed in the GT10 before shipment from the factory It is not necessary to transfer the font data when the used font is not changed 7 3 Error display function If an error occurs between the GOT and the memory loader during the transfer an error message will appear on the GOT screen Apply remedies according to the display a Chapter 12 Troubleshooting Turning OFF and ON the power or touching the screen will close the error message screen When this function is used Ver 01 08 00 or later of the standard monitor OS of the
16. T The GOT startups with OS installation screen The OS can be transferred from GT Designer2 Version2 or GT Designer3 Version O without displaying the OS installation screen depending on the combination of the GOT and the standard monitor OS Refer to the following manual for details about OS installation screen lt 3 GT10 User s Manual 3 Set the Data selection switch to PROJECT OS and the RD WR selection switch to WR and select the data to be transferred and transfer direction 4 Press the ENT key to determine the data to be transferred and transfer direction SET RUN LED will be orange If the next operation is not performed within 30 seconds after the ENT key is pressed SET RUN LED will be unlit and the operations that have been made will be canceled When the Data selection switch or the RD WR selection switch is operated after the data to be transferred and the transfer direction are determined the operations that have been made will be canceled 5 Press the ENT key again to start the transfer SET RUN LED will be green flashing 6 Turn OFF the GOT and remove the memory loader after the transfer is completed SET RUN LED will be green flashing Refer to the Chapter 12 Troubleshooting for details on handling errors during transferring 10 2 When the Data selection switch is PROJECT Project data _ _ gt GT1020 GT1030 Memory loader
17. Write protection switch 2 Connect the memory loader to the GOT and turn ON the GOT 3 Set the Data selection switch to PROJECT OS and the RD WR selection switch to RD and select the data to be transferred and transfer direction 4 Press the ENT key to determine the data to be transferred and transfer direction SET RUN LED will be orange If the next operation is not performed within 30 seconds after the ENT key is pressed SET RUN LED will be unlit and the operations that have been made will be canceled When the Data selection switch or the RD WR selection switch is operated after the data to be transferred and the transfer direction are determined the operations that have been made will be canceled 5 Press the ENT key again to start the transfer SET RUN LED will be green flashing 6 Turn OFF the GOT and remove the memory loader after the transfer is completed SET RUN LED will be green flashing Refer to the Chapter 12 Troubleshooting for details on handling errors during transferring 11 2 When the Data selection switch is PROJECT Project data Resource data GT1020 GT1030 Memory loader 1 Turn OFF the Write protection switch 2 Connect the memory loader to the GOT and turn ON the GOT 3 Set the Data selection switch to PROJECT and the RD WR selection switch to RD and select the data to be transferred and transfer direction 4 Press the ENT key to determine the
18. acquire proficiency in handling and operating the product Make sure to 1 When GT10 LDR is connected to a PC via the USB hub the power supply of the USB hub must be supplied by the AC adopter of the USB hub learn all the product information safety information and precautions Standard Remark GT10 LDR connected to the USB hub may not work properly depending on the PC environment In the case connect the GT10 LDR directly to the USB port on the PC And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user EMI Compliance with all relevant aspects of the 2 Specifications Registration EN61131 2 2007 standard Radiated Emissions B f The company name and the product name to be described in this manual are the Programmable C li TETE i EEE 2 1 General Specifications registered trademarks or trademarks of each company controllers De teria WIE Severn eer eye ASPECTS C 4 _ _ EEE Equipment standard Pare Item Specifications Effective April 2015 r direment andiests EMS ESD RF electromagnetic field EFTB Surge RF ve Ap q conducted disturbances and Power frequency Operating ambient temperature 0 to 40 C Specifications are subject to change without notice magnetic field 2007 MITSUBISHI ELECTRIC CORPORATION Storage ambient temperature 20 to 60 C Safety Precaution Read these precautions before using For more details please contact
19. and transfer direction SET RUN LED will be orange If the next operation is not performed within 30 seconds after the ENT key is pressed SET RUN LED will be unlit and the operations that have been made will be canceled When the Data selection switch or the RD WR selection switch is operated after the data to be transferred and the transfer direction are determined the operations that have been made will be canceled 5 Press the ENT key again to start the transfer SET RUN LED will be green flashing 6 Turn OFF the GOT and remove the memory loader after the transfer is completed SET RUN LED will be green flashing Refer to the Chapter 12 Troubleshooting for details on handling errors during transferring 11 2 When the Data selection switch is PROJECT Project data Resource data GT1020 GT1030 Memory loader 1 Turn OFF the Write protection switch 2 Connect the memory loader to the GOT and turn ON the GOT 3 Set the Data selection switch to PROJECT and the RD WR selection switch to RD and select the data to be transferred and transfer direction 4 Press the ENT key to determine the data to be transferred and transfer direction SET RUN LED will be orange If the next operation is not performed within 30 seconds after the ENT key is pressed SET RUN LED will be unlit and the operations that have been made will be canceled When the Data selection switch or t
20. ane pore Dong Sg can caves tie Memory loader ar ca leto be GT10 LDR Memory loader USER S MANUAL This manual 1 Item Specifications Item Specifications damaged or can cause a malfunction due to a cable connection fault Do not bent at a sharp angle or tie the memory loader cables Doing so can cause the breaking of the cables User memory Flash ROM 7 5Mbyte RD WR selection switch f Memory Life Number of write Paddle switch times 10O OO time Data selection switch DISPOSAL PRECAUTIONS NCAUTION POWER green Switch Tactile switch f F The use of 100 thousand times is due for e When disposing of the product handle it as industrial waste LED SET RUN green red orange ENT key replacement operating force 2 55N 0 69N e ERROR green red orange Write protection switch Slide switch PRECAUTIONS A CAUTION Ext I di i W70 2 75 xH110 4 D21 0 82 inch e Make sure to transport the memory loader and or relevant unit s in the Breeton ree ete nes Sennen manner they will not be exposed to the impact exceeding the impact Weight 0 2kg resistance described in the general specifications of this manual as they are precision devices Failure to do so may cause the unit to fail 4 ROM in which new data can be written without deleting the written data 2 3 Communication Specifications 2 4 Power Supply Specifications No Name O OS Specifications Hom Speen fem Specie 7 Write protect
21. ata to GT10 or between a PC GT Designer2 Ver 2 77F or later GT Designer3 Ver 1 01B or accordance with the contents of this note will comply with the following standards later and GT10 LDR Compliance to EMC directive for the entire mechanical module should be checked by GT1020 GT1030 the user manufacturer For more details please contact the local Mitsubishi Electric GT10 LDR Memory loader sales site Attention L U se r S M a n u al e This product is designed for use in industrial applications e Authorized Representative in the European Community Mitsubishi Electric Europe B V GRAPHIC OPERATION TERMINAL Manual Number JY997D29501F Gothaer Str 8 40880 Ratingen Germany GO IDo Apulep ts Requirement for Compliance with EMC directive D supplied The following products have shown compliance through direct testing to the identified w standards and design analysis forming a technical construction file to the European Directive for Electromagnetic Compatibility 2004 108 EC when used as directed by GT Designer2 Ver 2 77F or later the appropriate documentation GT Designer3 Ver 1 01B or later Type Programmable Controller Open Type Equipment USB connecting This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and manuals of relevant products fully to
22. directions option devices or physical damage Must be free of lamp black corrosive gas flammable gas or excessive amount of electro conductive dust particles and must be no Depending on circumstances procedures indicated by CAUTION may also be sold separately Operging atmosphere direct sunlight Same as for saving linked to serious results GT Designer2 Describes methods of the GT Designer2 ate In any case it is important to follow the directions for usage Version2 Basic installation operation basic operation for Operating altitude 2000 m 6562 ft max SH 080529ENG Operation Data drawing and transmitting data to 7 MOUNTING PRECAUTIONS NC AUTION Transfer Manual GOT1000 series 1D7M24 Overvoltage category 3 ll or less For GOT1000 Series sold separately f Pollution degree 4 2 or less e Use the memory loader in the environment that satisfies the general specifications described in GT10 User s manual Never use the product in GT Designer3 Describes methods of the GT Designer3 Cooling method Self cooling areas with excessive dust oily smoke conductive dusts corrosive gas salt Version1 Screen installation operation basic operation for oi ogqg66ENG air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or exposed or Wo cael ee ale a data to 1D7MB9 1 The wet bulb temperature is 39 C or less ee ee ee Fundamentals sold separately 2 Do not use or store the GOT under pressure higher than t
23. ection Data selection switch Switch to select the data to be transferred ENT key Switch to determine the transfer direction and the data to be transferred and to start the transfer POWER LED LED to show power status Specifications Input power supply voltage Supplied from the GOT or PC Supplied from bus Unit mm inch No 7 Write protection switch 8 USB port 9 Reference plate operating instructions 10 Reference plate error contents 11 Transfer cable 12 Strap hole 13 Part to be labeled Specifications Switch to prevent the memory loader from being written to the data Connection port with a PC with protection cap Described operating instructions of the memory loader Described lighting status of ERROR LED Cable to be connected with the GOT A hole to attach a strap Space to be labeled created by user 14 Rating plate Nameplate 5 LED lighting specification LED Name Status o Contents Power is supplied POWER Power is not supplied Before starting the transfer The transfer direction and the data to be transferred are determined SET RUN The transfer is running The transfer is completed The transfer is aborted Write protection switch ON The GOT type that is set in the data to be transferred differs from that of the GOT to which the data is transferred ERROR lg ee ee OS is different from that of the project data Communication error occurs between the GOT and the memory loader
24. ection SET RUN LED will be orange If the next operation is not performed within 30 seconds after the ENT key is pressed SET RUN LED will be unlit and the operations that have been made will be canceled When the Data selection switch or the RD WR selection switch is operated after the data to be transferred and the transfer direction are determined the operations that have been made will be canceled 4 Press the ENT key again to start the transfer SET RUN LED will be green flashing 5 Turn OFF the GOT and remove the memory loader after the transfer is completed SET RUN LED will be green flashing Refer to the Chapter 12 Troubleshooting for details on handling errors during transferring 11 To read out the data from the GOT to the Memory loader The standard monitor OS communication driver project data and resource data are read out from the GOT to the memory loader The operation procedure is described below 11 1 When the Data selection switch is PROJECT OS Project data Communication driver Standard monitor OS Resource data o a GT1020 GT1030 Memory loader 1 Turn OFF the Write protection switch 2 Connect the memory loader to the GOT and turn ON the GOT 3 Set the Data selection switch to PROJECT OS and the RD WR selection switch to RD and select the data to be transferred and transfer direction 4 Press the ENT key to determine the data to be transferred
25. en light The transfer is completed _V f Red flashing The transfer is aborted Unit mm inch aii al POWER LED is not lit No errors i Green light 1 Write protection switch ON TATE PROTECT J N Cm IS Unit mm inch Green flashing The GOT type that is set in the data to be transferred differs from that of the GOT to which the data is transferred foe SS MPN deka ERROR Red light The data to be transferred is broken O ed light The major version of the standard monitor OS is different from that of the project data Red flashing Communication error occurs between the GOT and the memory loader 4 Part Name Password is set in the project data OS installation screen is not active An error message appears on the GOT screen Apply remedies according to the display Refer to the Chapter 12 Troubleshooting for details on handling errors 6 Switch operation specification POWER SET RUN ERROR a OD 10 Switch Name Specifications Cc WR T LDR GOT 4 0s PROJECT Switch to select read write direction RD The data is read out from the GOT to the memory loader WR The data is written from the memory loader to the GOT 11 RD WR selection switch Switch to select the data to be transferred e When reading out the data from the GOT to the memory loader PROJECT OS The standard monitor OS communication driver project data and resource data are read out from the GOT to the memory l
26. ermine the transfer direction and the data to be transferred and to start the transfer The transfer starts by pressing the key twice e The first pressing of the key determines the read write direction and the data to be transferred After the read write direction and the data to be transferred are determined if RD WR selection switch and Data selection switch are operated the operations that have been made will be canceled The ENT key must be pressed within 30 seconds after the first pressing of the ENT key Failure to do so cancels the operations that have been made e The second pressing of the key starts the transfer When the standard monitor OS and communication driver are transferred from the memory loader to the GOT starting up the GOT with OS installation screen is required 7 Function specification 7 1 Transfer function 1 Standard monitor OS Font data Communication driver Project data 2 Project data Resource data GT Designer2 GT Designer3 Data Transfer data 3 Standard monitor OS Font data Communication driver Project data er 4 Standard monitor OS Communication driver Project data Resource data GT1020 GT1030 Memory loader O Available to transfer x Unavailable to transfer selection switch Transfer direction Standard monitor OS Resource data Project data Communication Operation driver 1 PC gt Memory loader O O After a
27. es the power to the GOT connected to the memory loader State of ERROR LED content Write protection switch ON Green Nght Turn OFF the Write protection switch Green The GOT type that is set in the data to be transferred differs flashin from that of the GOT to which the data is transferred 9 Check the GOT type to which the memory loader is connected The data to be transferred is broken or the major version of the standard monitor OS is different from that of the project data e Write the standard monitor OS communication driver and project data from GT Designer2 or GT Designer3 to the Red light memory loader again and then transfer them to the GOT again e Set the Data selection switch to PROJECT OS and read out all data from the GOT to the memory loader and then transfer them to the GOT again Communication error occurs between the GOT and the memory loader Red fashing e Check the connection with the communication cable e Check that power supply is stable lighting of POWER LED Red Green Password is set in the project data Reset the password with the numeric keypad on the GOT OS installation screen is not active Orange amp f bn Install the data after the OS installation screen is displayed on Green the GOT This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any proble
28. he RD WR selection switch is operated after the data to be transferred and the transfer direction are determined the operations that have been made will be canceled 5 Press the ENT key again to start the transfer SET RUN LED will be green flashing 6 Turn OFF the GOT and remove the memory loader after the transfer is completed SET RUN LED will be green flashing Refer to the Chapter 12 Troubleshooting for details on handling errors during transferring 12 Troubleshooting 12 1 GOT error message When communication between the GOT and the memory loader does not work check the following contents depending on the GOT error messages GOT error message Remedy Write protection switch is ON Write protection switch ON Turn OFF the Write protection switch The GOT type that is set in the data to be transferred differs from that of the GOT to which the data is transferred Check the GOT type to which the memory loader is connected Wrong GOT model is connected The data to be transferred is broken or the major version of the standard monitor OS is different from that of the project data e Write the standard monitor OS communication driver and Corrupt data or OS version variance project data from GT Designer2 or GT Designer3 to the memory loader again and then transfer them to the GOT again e Set the Data selection switch to PROJECT OS and read out all data from the GOT to the memory loader and the
29. he atmospheric pressure of altitude Om Oft Failure to observe this instruction may cause a malfunction AN GIEC Steer FS Mam UricHon OF Product Hamaga Of deterioration When the air inside the control panel is purged by pressurization the surface sheet may be lifted by high pressure As a result the touch panel may be difficult to press and the sheet may be peeled off STARTUP MAINTENANCE 3 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the PRECAUTIONS CAUTION Bundled Items machinery within the premises Category II applies to equipment for which electrical power is supplied from fixed facilities The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V Do not disassemble or modify the memory loader Bundled item Quantity Doing so can cause a failure malfunction injury or fire 4 This index indicates the degree to which conductive material is generated in the environment where the equipment is used Do not touch the conductive and electronic parts of the memory loader GT10 LDR memory loader 1 In pollution degree 2 only non conductive pollution occurs but temporary conductivity may be produced due to condensation directly Doing so can cause a memory loader malfunction or failure When unplugging the cable connected to the GOT do not hold and pull the USB cable 1m 1 2 2 Performance Specifications C
30. ion switch Switch to prevent the memory loader from being written to the data Conforming to RS232 DC5V DC4 75 to 5 25V F F GOT communication Transmission speed 115 200bps Input power supply voltage Supplied from the GOT or PC Supplied from bus 8 USB port Connection port with a PC with protection cap Connector shape MINI DIN 6Pins Male power 9 Reference plate operating instructions Described operating instructions of the memory loader Conforms to USB2 0 Full speed is supported Fuse Reference plate error contents ihti Performs ihe conversion between USB and serial it 10 Reference plate error contents Described lighting status of ERROR LED PC communication GT10 LDR After serial conversion transmission Power consumption 0 7W 140mA DC5V or less 11 Transfer cable Cable to be connected with the GOT speed is 115 200bps Connector shape USB MINI B 5Pins Receptacle 12 Strap hole A hole to attach a strap 13 Part to be labeled Space to be labeled created by user 3 External Dimensions External Dimensions Cable length 14 Rating plate Nameplate 5 LED lighting specification LJ Oo oOo Ss POWER LED is lit Power is supplied POWER M so l POWER LED is not lit Power is not supplied an Ke m E POWER LED is not lit Before starting the transfer P a 8 Orange light The transfer direction and the data to be transferred are determined SET RUN Green flashing The transfer is running 240 9 44 Gre
31. ling 1 The wet bulb temperature is 39 C or less 2 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude Om Oft Failure to observe this instruction may cause a malfunction When the air inside the control panel is purged by pressurization the surface sheet may be lifted by high pressure As a result the touch panel may be difficult to press and the sheet may be peeled off 3 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within the premises Category II applies to equipment for which electrical power is supplied from fixed facilities The surge voltage withstand level for up to the raged voltage of 300 V is 2500 V 4 This index indicates the degree to which conductive material is generated in the environment where the equipment is used In pollution degree 2 only non conductive pollution occurs but temporary conductivity may be produced due to condensation 2 2 Performance Specifications Item User memory Memory Life Number of write times POWER green LED SET RUN green red orange ERROR green red orange Flash ROM 7 5Mbyte Item RD WR selection switch Paddle switch Data selection switch Tactile switch The use of 100 thousand times is due for replacement operating force 2 55N 0 69N Write protection switch Slide switch Exter
32. ll data in the memory loader is deleted the data O selected with GT Designer2 or GT Designer3 is written to the memory loader all at once 2 Memory loader gt PC The project data or resource data is read out from the memory loader to a PC PROJECT 3 Memory loader gt OS All data in the memory loader is written to the GOT GOT PROJECT Only the project data in the memory loader is written to the GOT PROJECT os After all data in the memory loader is deleted all data in the GOT is read out to the memory loader 4 GOT gt Memory loader PROJECT 14 Ver 01 08 00 or later of the standard monitor OS of the GT10 is applicable 2 Wer 01 11 00 or later of the standard monitor OS of the GT10 is applicable 3 Ver 2 91V or later of GT Designer2 or Ver 1 01B or later of GT Designer3 are applicable 7 2 Password reset function on the GOT When reading out the project data from the memory loader if the password is set in the project data password entry screen will appear on the GOT After entering the password password is reset by pressing the ENT key on the screen The data will be transferred from the GOT to the memory loader The operation procedure is described below When this function is used Ver 01 08 00 or later of the standard monitor OS of the GT10 is required 1 When the upload is started password entry screen will appear on the GOT Touch the INPUT key GTIC
33. ms involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JY997D29501F A MITSUBISHI ELECTRIC Compliance with EC directive CE Marking 1 Overview This note does not guarantee that an entire mechanical module produced in GT10 LDR memory loader is the memory transfer module that reads writes the d
34. n transfer them to the GOT again Communication error occurs between the GOT and the memory loader e Check the connection with the communication cable e Check that power supply is stable lighting of POWER LED Communication error GOT contains a system password Password is set in the project data Reset the password with the numeric keypad on the GOT OS installation OS installation screen is not active screen isn t active the GOT Install the data after the OS installation screen is displayed on 12 2 LED display on the memory loader If communication cannot be established between the GOT and a PC using memory loader confirm the following status by checking display LED in memory loader State of POWER LED Content POWER LED The DC5V power supply from the GOT or the personal is lit computer is normally supplied In case of no communication i check the status of ERROR LED The DC 5V power supply from the GOT or the personal computer is not supplied Check the items below e Turn ON the power ae LED e Check the connection with the USB cable i e Check the connection with the GOT e Check that PLC is not overloaded when PLC supplies the power to the GOT connected to the memory loader Biogen a Contents R Write protection switch ON Green ygi Turn OFF the Write protection switch Green The GOT type that is set in the data to be transferred differs flashin from that of the GOT to which the data is transferred
35. nal dimensions W70 2 75 xH110 4 33 xD21 0 82 mm inch Specifications Specifications 100 000 times Switch ENT key Weight 0 2kg 1 ROM in which new data can be written without deleting the written data 2 3 GOT PC communication Communication Specifications 2 4 Power Supply Specifications Item Specifications Item Conforming to RS232 Transmission speed 115 200bps Connector shape MINI DIN 6Pins Male power DC5V DC4 75 to 5 25V communication Conforms to USB2 0 Full speed is supported Fuse Performs the conversion between USB and serial in GT10 LDR After serial conversion transmission speed is 115 200bps Connector shape USB MINI B 5Pins Receptacle Power consumption 0 7W 140mA DC5V or less 3 External Dimensions External Dimensions Cable length C SET RUN ERROR o a RD WR GOT gt LOR ser ENT _ PROJECT 5 S 405 m pa R o w Qi Q E gs YS 240 9 44 GT10 LDR 70 2 75 lt WRITE PROTECT F ON T SH Unit mm inch Weight 0 2kg k gt 28 0 LZ 4 Part Name POWER SET RUN ERROR D OD 10 T DRGOT 11 4 5 14 GT10 LDR 7 8 WATE PROTECT OFF ON ee 2 No Specifications 1 2 3 SET RUN LED LED to show that the settings are being checked the transfer is running ERROR LED LED to show error status RD WR selection switch Switch to select read write dir
36. nsport the memory loader and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual as they are precision devices Failure to do so may cause the unit to fail Compliance with EC directive CE Marking This note does not guarantee that an entire mechanical module produced in accordance with the contents of this note will comply with the following standards Compliance to EMC directive for the entire mechanical module should be checked by the user manufacturer For more details please contact the local Mitsubishi Electric sales site Attention e This product is designed for use in industrial applications e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany Requirement for Compliance with EMC directive The following products have shown compliance through direct testing to the identified standards and design analysis forming a technical construction file to the European Directive for Electromagnetic Compatibility 2004 108 EC when used as directed by the appropriate documentation Type Programmable Controller Open Type Equipment Standard Remark Compliance with all relevant aspects of the EMI standard Radiated Emissions EN61131 2 2007 Programmable controllers Equipment requirement and tests Compliance with all relevant aspec
37. o the following manual for details about OS installation screen L3 GT10 User s Manual 3 Set the Data selection switch to PROJECT OS and the RD WR selection switch to WR and select the data to be transferred and transfer direction 4 Press the ENT key to determine the data to be transferred and transfer direction SET RUN LED will be orange If the next operation is not performed within 30 seconds after the ENT key is pressed SET RUN LED will be unlit and the operations that have been made will be canceled When the Data selection switch or the RD WR selection switch is operated after the data to be transferred and the transfer direction are determined the operations that have been made will be canceled 5 Press the ENT key again to start the transfer SET RUN LED will be green flashing 6 Turn OFF the GOT and remove the memory loader after the transfer is completed SET RUN LED will be green flashing Refer to the Chapter 12 Troubleshooting for details on handling errors during transferring 10 2 When the Data selection switch is PROJECT ms O Project data _ _ _ S GT1020 GT1030 Memory loader 1 Connect the memory loader to the GOT and turn ON the GOT 2 Set the Data selection switch to PROJECT and the RD WR selection switch to WR and select the data to be transferred and transfer direction 3 Press the ENT key to determine the data to be transferred and transfer dir
38. oader PROJECT The project data and resource data are read out from the GOT to the memory loader e When writing the data from the memory loader to the GOT PROJECT OS The standard monitor OS font data communication driver and project data are written from the memory loader to the GOT PROJECT The project data is written from the memory loader to the GOT 14 Data selection switch Switch to prevent the memory loader from being written to the data GTOLDR Write protection switch ON The data cannot be written neither from the GOT or a PC GT Designer2 GT Designer3 to the memory loader OFF The data can be written from the GOT or a PC GT Designer2 GT Designer3 to the memory loader 7 8 OFF ON Switch to determine the transfer direction and the data to be transferred and to start the transfer The transfer starts by pressing the key twice e The first pressing of the key determines the read write direction and the data to be transferred After the read write direction and the data to be transferred are determined if RD WR selection switch and Data selection switch are operated the operations that have been made will be canceled The ENT key must be pressed within 30 seconds after the first pressing of the ENT key Failure to do so cancels the operations that have been made e The second pressing of the key starts the transfer ENT key No Specifications 1 POWER LED LED to
39. onfiguration tab to display the communication configuration dialog Select the same COM number as the COM number of the personal computer when the setting communication port screen appears Click OK Communication Configuration lt Note gt GT10 LDR has USB RAS232 converter built in Hence use the following RS232 setting for the communication configuration Part No Baud Rate 115200 v bps 9 Transfer procedures between a PC and the Memory loader 9 1 To write the data from a PC GT Designer2 Ver 2 77F or later GT Designer3 Ver 1 01B or later to the memory loader The standard monitor OS communication driver font data and project data are written from a PC GT Designer2 GT Designer3 to the memory loader The operation procedure is described below Standard monitor OS Communication driver Font data Project data Memory loader GT Designer2 GT Designer3 1 Turn OFF the Write protection switch 2 Connect a PC GT Designer2 GT Designer3 to the memory loader with USB cable supplied 3 Write the data from a PC GT Designer2 GT Designer3 to the memory loader Refer to the following manual for details about operating instructions of GT Designer2 or GT Designer3 ce GT Designer2 Version O Basic Operation Data Transfer Manual GT Designer3 Version Screen Design Manual Fundamentals 9 2 To read out the data from the memory loader to a PC GT Designer2 Ver 2 77F or later GT Designer3
40. ry or physical damage CAUTION Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage MOUNTING PRECAUTIONS CAUTION e Use the memory loader in the environment that satisfies the general specifications described in GT10 User s manual Never use the product in areas with excessive dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or exposed to high temperature condensation or rain and wind Not doing so can cause an electric shock fire malfunction or product damage or deterioration STARTUP MAINTENANCE PRECAUTIONS CAUTION Do not disassemble or modify the memory loader Doing so can cause a failure malfunction injury or fire Do not touch the conductive and electronic parts of the memory loader directly Doing so can cause a memory loader malfunction or failure When unplugging the cable connected to the GOT do not hold and pull the cable portion Doing so can cause the memory loader or cable to be damaged or can cause a malfunction due to a cable connection fault Do not bent at a sharp angle or tie the memory loader cables Doing so can cause the breaking of the cables DISPOSAL PRECAUTIONS CAUTION e When disposing of the product handle it as industrial waste TRANSPORTATION PRECAUTIONS CAUTION e Make sure to tra
41. show power status required 1 When the standard monitor OS and communication driver are transferred from the memory loader to the GOT starting up the GOT with OS installation screen is 2 SET RUN LED LED to show that the settings are being checked the transfer is running 3 ERROR LED LED to show error status 4 RD WR selection switch Switch to select read write direction 5 Data selection switch Switch to select the data to be transferred 6 ENT key Switch to determine the transfer direction and the data to be transferred and to start the transfer 7 Function specification 7 1 Transfer function 1 Standard monitor OS Font data Communication driver Project data 2 Project data Resource data GT Designer2 GT Designer3 Data Transfer data 3 Standard monitor OS Font data Communication driver Project data 4 Standard monitor OS Communication driver Project data Resource data GT1020 GT1030 Memory loader O Available to transfer x Unavailable to transfer selection switch Transfer direction Standard monitor OS Resource data Project data Communication Operation driver 1 PC gt Memory loader O O After all data in the memory loader is deleted the data O selected with GT Designer2 or GT Designer3 is written to the memory loader all at once 2 Memory loader gt PC The project data or resource data is read out from the memory loader to a
42. signer3 ce GT Designer2 Version O Basic Operation Data Transfer Manual GT Designer3 Version Screen Design Manual Fundamentals 9 2 To read out the data from the memory loader to a PC GT Designer2 Ver 2 77F or later GT Designer3 Ver 1 01B or later The project data and resource data are read out from the memory loader to a PC GT Designer2 GT Designer3 The operation procedure is described below Project data Resource data PC M GT Designer2 GT Designer3 emory loader 1 Connect a PC GT Designer2 GT Designer3 to the memory loader with USB cable supplied 2 Select the data to be uploaded in a PC GT Designer2 GT Designer3 and read it out from the memory loader Refer to the following manual for details about operating instructions of GT Designer2 or GT Designer3 a GT Designer2 Version Q Basic Operation Data Transfer Manual GT Designer3 Version O Screen Design Manual Fundamentals 10 To write the data from the Memory loader to the GOT The standard monitor OS communication driver font data and project data are written from the memory loader to the GOT The operation procedure is described below 10 1 When the Data selection switch is PROJECT OS Standard monitor OS Communication driver Font data Project data se GT1020 GT1030 Memory loader 1 Connect the memory loader to the GOT 2 Turn ON the GOT by pressing the lower right corner of the GO
43. ts of the standard ESD RF electromagnetic field EFTB Surge RF conducted disturbances and Power frequency magnetic field EMS For more details please contact the local Mitsubishi Electric sales site Associated Manuals The following manuals are relevant to this product When these loose manuals are required please consult with our local distributor Manual Number Model Code Manual name Contents Describes the GT10 hardware relevant content such as part names external dimensions mounting power supply wiring specifications and introduction to option devices JY997D24701 GT10 User s Manual 09R819 sold separately GT Designer2 Version2 Basic Operation Data Transfer Manual For GOT1000 Series Describes methods of the GT Designer2 installation operation basic operation for drawing and transmitting data to GOT1000 series SH 080529ENG 1D7M24 sold separately GT Designer3 Version1 Screen Design Manual Describes methods of the GT Designer3 installation operation basic operation for drawing and transmitting data to SH 080866ENG For GOT1000 Series GOT1000 series 1D7MB3 Fundamentals sold separately Bundled Items Bundled item Quantity GT10 LDR memory loader 1 USB cable 1m 1 GT10 LDR Memory loader USER S MANUAL This manual 1 1 Overview GT10 LDR memory loader is the memory transfer module that reads writes the data to GT10 or between a PC GT Designer2 Ver 2
44. unication driver and Corrupt data or OS version variance project data from GT Designer2 or GT Designer3 to the memory loader again and then transfer them to the GOT again e Set the Data selection switch to PROJECT OS and read out all data from the GOT to the memory loader and then transfer them to the GOT again Communication error occurs between the GOT and the memory loader Communication error e Check the connection with the communication cable e Check that power supply is stable lighting of POWER LED GOT contains a system password Password is set in the project data Reset the password with the numeric keypad on the GOT OS installation OS installation screen is not active screen isn t active the GOT Install the data after the OS installation screen is displayed on 12 2 LED display on the memory loader If communication cannot be established between the GOT and a PC using memory loader confirm the following status by checking display LED in memory loader Stata of Contents POWER LED POWER LED The DCSV power supply from the GOT or the personal is lit computer is normally supplied In case of no communication check the status of ERROR LED The DC 5V power supply from the GOT or the personal computer is not supplied Check the items below e Turn ON the power a LED e Check the connection with the USB cable l e Check the connection with the GOT e Check that PLC is not overloaded when PLC suppli
45. us controllers 5 gt Keyboards gt Mice and other pointing devices Monitors E Network adapters a Communications Pope COM1 J Ries lt _ B MB Processors Sound video and game controllers auma lt A Standard Universal PCI to USB Host Controller USB Root Hub Check following GT10 LDR is indicated at A GT10 LDR COM is indicated at B indicates the COM number used in Memory loader Install the GT Designer2 or GT Designer3 again when is displayed Select the GT Designer2 or GT Designer3 COM number as the COM number currently assigned on the screen above 8 3 Setting GT Designer2 Click Communication Communicate with GT10 LDR Communication configuration tab Select the same COM number as the COM number of the personal computer when the setting communication port screen appears Click Update Communicate with GT10 LDR GT10 LDR gt Computer Project Communication configuration GT10 LDA gt Computer Resource Memory information Computer gt GT10 LDA 0S Project lt Note gt The GT10 LDRA includes a built in USB RS232 converter Therefore the following communication configuration uses RS232 as standard Details Port No Baudrate 115200 v bps Test 8 4 Setting GT Designer3 Click Communication Communicate with GT10 LDR to display the communicate with GT10 LDR screen Click the Communication C
46. y clicking Start Control Panel Device Manager in the menu of the personal computer FE E IDE ATAJATAPI controllers J Other devices a7 Ports COM amp LPT aF Printer Port LPT1 System devices Universal Serial Bus controllers 5 gt Keyboards gt Mice and other pointing devices Monitors E Network adapters a Communications Pope COM1 7 Ge lt B MB Processors Sound video and game controllers auma lt A Standard Universal PCI to USB Host Controller USB Root Hub Check following GT10 LDR is indicated at A GT10 LDR COM is indicated at B indicates the COM number used in Memory loader Install the GT Designer2 or GT Designer3 again when is displayed Select the GT Designer2 or GT Designer3 COM number as the COM number currently assigned on the screen above 8 3 Setting GT Designer2 Click Communication Communicate with GT10 LDR Communication configuration tab Select the same COM number as the COM number of the personal computer when the setting communication port screen appears Click Update Communicate with GT10 LDR GT10 LDR gt Computer Project GT10 LDR gt Computer Resource Memory information Communication configuration Computer gt GT10 LDR 05 Project lt Note gt The GT10 LDRA includes a built in USB RS232 converter Therefore the following communication configuration uses RS232 as

Download Pdf Manuals

image

Related Search

Related Contents

Genius Slimstar 110  Nokia 7270 User Guide      Whirlpool RS3025XB User's Manual  Videoregistratore digitale  VGN-FS series  manual for ZA-180 mini DV      

Copyright © All rights reserved.
Failed to retrieve file