1. Unplug mains before maintenance and at least 10 minutes cool off Appliance do not illegal open or demount Clean up dust only from outer surface for ex diffuser and lenses Use vacuum or dumpy duster warm water Before reinstalling to check failure free state no wet parts If you have any question please contact support leaderlight sk Installation Surface mounting is easy by using surface holder Mounting on surface with surface holder D LL41 400 Part A PartA Part B R aia Eh Part B 1 1 1 Unlock the screws on the surface holder and divide it into two parts Part B E 1 1 2 The part B fix to the surface Part A 1 1 3 The power cable string on surface part A The surface holder part A screw on the basic unit Bk 1 1 4 Connect the fixture to AC power supply and match part A on part B and fix with screws Order code Product name LL30 520 LL A3 BIG POINT 01 SURFACE W LL30 530 LL A3 BIG POINT 01 SURFACE N If you have any question please contact support leaderlight sk
2. Leader Light s r o M Gorkeho 33 SK 052 01 Spisska Nova Ves Slovakia www leaderlight eu USER MANUAL LL A3 BIG POINT 01 SURFACE LEADER L GHT professional lighting products COMPLIMENTS ON YOUR PURCHASE All dimensions are in milimeters BASIC 59 io Following items are included LL A3 BIG POINT 01 BASIC with 1 5m cable 1 pe LL HOLDER A3 BIG POINT SURFACE 1 pe User manual 1 pc Additional items needed Mounting accessories as necessary Content 01 SAFETY INFORMATION 01 1 Risk of eyes damage 01 2 Protection from electric shock 01 3 Fire prevention 02 PRODUCT SPECIFICATION 02 1 Technical Specification 03 INSTALLATION 03 1 Unpacking 03 2 Physical installation 03 3 Electrical installation 04 MAINTENANCE ENVIRONMENT H E Do not throw away the appliance with the normal household waste at the end of its life but hand it in at an official collection point for recycling By doing this you help to preserve the environment MMxX Leader Light All right reserved 01 SAFETY INFORMATION ZN WARNING Carefully read before installing powering or servicing Nothing to do if anything misunderstand Installation can be done only by a qualified professional in accordance with relevant local codes 01 1 Risk of eyes damage A Do not look directly into LED lamps Do not look into light beam from a distance of less than 40 cm 16 inches 01 2 Protection
3. from electric shock A Shut down power before installation or maintenance Luminaries and recommended AC power supply must be installed by a qualified professional in accordance with relevant local codes Only acceptable source of AC power and frequency that complies with local building and electrical codes to use Do not use or do not connect the products if the power cable power plug or fixtures are any way damaged wet or if they are overheating Do not modify alter or attempt to service the LeaderLight appliance Doing so will void the warranty Before removing or installing any cover or part of appliance disconnect it from AC power Appliance always connect to earth eltech 01 3 Fire prevention A Follow all safety consideration Thermostatic switches or fuses never to bypass Device never shield Around the axis of the fitting 180 must be maintained space for cooling Minimum distance from the surrounding objects must be 100mm 4 in LEDs never direct cover with filters or other materials Allowing max ambient temperature is 40 C 104 F LL A3 BIG POINT 01 SURFACE WIN is not suitable for standard dimming 02 PRODUCT SPECIFICATION 02 1 Technical Specification Lamp type 1 x Acriche White 6300 K and Neutral 3000 K Lifetime Over 35 000 hrs Optic Standard 5 on request 25 40 60 Max input power 4 6W 220 240V 50 60Hz AC 1 5m cable On request US version 100 120V Net wei
4. ght 0 35 kg Dimensions Hx 59mm x 60mm without bracket IP IP65 Ambient temp Ta Maximum 40 C Cooling Conventional Power connection Materials and finish Housing powder painted anodized aluminium RAL9006 other colours on request Installation Surface mounting Edition A 2010 03 INSTALLATION 03 1 Unpacking Unpack carefully This is electronic equipment and should be handled carefully Damaged delivered package or if are any mechanical parts broken it must be claim immediately by the transport company Photo pictures as evidence are valuable for future claim 03 2 Physical installation Loading capacity of bearing area has to be at least 10 times the weight of all device clusters luminaries clamps cables Heigrbreadth from combustible materials is 0 5m 03 3 Connecting to AC power Ay To tackle all Safety Information 01 For protection from electric shock the device must be grounded earthed It is not necessary to open the fixture before power supply Power supply is solved simple with 1 5m cable Cord plug connections Wire Colour Screw US L live brown yellow or brass N neutral blue silver a ground earth yellow green green 04 MAINTENANCE ZN To tackle all Safety Information 01 Damage caused by inadequate cleaning or maintenance is not coveredby warranty Regular cleaning is demand dust dirt Maintenance policy
Download Pdf Manuals
Related Search
Related Contents
instruction manual manuel d`instructions GA-9SISL - Billiger.de msm net meissner Defiant T3610B Instructions / Assembly "user manual" Philips Power multiplier SPS2420C Manuel d`utilisation de TRAC - Infoterre CDA DV710SS Copyright © All rights reserved.
Failed to retrieve file