Home
Atop Serial-Ethernet Server GW51E
Contents
1. e E Physical COM2 COM3 Virtual COM Port COM4 Virtual COM Port COM5 Virtual COM Port COM6 Virtual COM Port TCP IP Network OS Driver Level SSES GW51E MINI Virtual COM Port Serial Line OOOO H Serial Line Nn Nn N CH CH 2 ef ae St o D D EC Oo J GC CH CH CH lt lt lt CH CH CH LA NO eeee Serial Device 4 3 6 1 Setup of a virtual COM driver Correspondence OS Atop Virtual COM driver can be used on Windows XP Windows 2000 Windows NT 4 0 SP5 or later Windows Me or Windows 98 Microsoft NT 2000 Terminal Server Installation Make sure you have turned off all anti virus software before beginning the installation Run AtopVcom exe program included in the CD to install Atop Virtual COM for your operating system Uninstalling 1 From Windows Start menu select Setting Control Panel Add Remove Programs 2 Select Serial IP for ATOP in the list of installed software 3 Click the Add Remove button to remove the program or from Windows start menu select programs Serial IP for ATOP Uninstall Serial IP for ATOP to remove the program User manual Version 1 0 ABLELinko Single Port Serial Server GW51E MINI Ba OD atOp 3 6 2 Virtual COM communication 3 6 2 1 Enable virtual COM on GW51E MINI From web browser access to GW51E MINI by typing its IP address click on COM link to access COM page on the top half of the page click on TCP S
2. Host Name 3 4 Configuration set by web browser It is also possible to modify various settings through the web server interface To do so please follow the steps below Log in to the system 1 From web browser type in the IP address of GW51E MINI in the URL Example http 10 0 50 100 2 The following authentication screen appears Please type in user name and password then click on OK The user name is admin and password is null by default eatop Technolo Ip User manual Version 1 0 ABLE Linko Single Port Serial Server GW51E MINI GW51E MNI 10 0 50 100 00 60 E9 00 B47C Mias TerminalSrv ver Dip Networking setup Click on the Networking link and the following screen appears This page indicates the default static IP address gateway IP address subnet mask information of GW51E MINI Please note that any setting change made on this page will not take effect until you restart device Copyright 2003 Atop Technologies Inc All rights reserved Designed in Taiwan 6 24 User manual Version 1 0 Ki PR ABLE Linke Single Port Serial Server GW51E MINI Ch Change the password 1 Click on the Security link and the following screen appears Miaton ABLELink Ethernet Serial Server Overview Security The default password is null you can change the password by filling Networking in the new password to New Password and Verified Password
3. 00 60 E9 00 64 CA 10 0 53 100 255 255 0 0 GW21E 1 85 TerminalSrv ver3 03 S om 10 0 57 57 00 60 E9 33 44 54 10 0 0 254 255 255 0 0 GW21S ME 1 2 ROMFS V1 2 om 10 0 70 26 00 60 E9 00 3D D0 10 0 0 254 255 255 0 0 GW26A 104 1 3 ATOP Proxi A SOYAL 2 1 U om 10 0 71 111 00 60 E9 00 B4 D5 10 0 0 254 255 255 0 0 GW21S 256 1 45 NewCAPS576 1 53 x MAC addr 00 60 E9 00 57 25 IP address MARIAA M Auto IP GateWay ji 0 0 0 254 Mack 255 255 0 0 Config How User ID admin Cancel Password Host Name Figure C2 Configuration dialog box 3 After you click the Configure Now button the target device will return an ACK message indicating the modification is successful as shown in the following mnonitor 4 Copyright 2003 Atop Technologies Inc All rights reserved Designed in Taiwan 22 24 User manual Version 1 0 ABLE Linke Single Port Serial Server GW51E MINI Psatop Please note monitor exe version 2 4 and above requires gw21le dil library to function properly The following table lists the functional descriptions for all the fields Field Name Broadcast IP Field Descriptions Except for the default IP 255 255 255 255 other items IPs are read from the file seg cfg This field specifies a detecting IP range It may be a designated IP ora broadcast IP Wishes Specifies minimum number of the devices you wish to get reply from after sending an Invite request If th
4. E9 00 B7 25 10 0 0 254 255 255 0 0 GW21S MINI 1 15 TerminalSrvverl 01 S om 10 0 50 98 00 60 E9 00 B4 AF 10 0 0 254 255 255 0 0 GW21S 256 1 45 NewCAPS576 V1 53 em 10 0 50 100 00 60 B3 6F AA CC 0060B3 6FAACC 10 0 0 254 255 255 0 0 GW21W 2 0 TerminalSrv ver3 07 SS om 10 0 51 100 00 60 E9 00 51 50 10 0 0 254 255 255 0 0 GW21S ME 1 1 ROMFS 1 1 om 10 0 53 1 00 60 E9 00 5E A8 10 0 0 254 255 255 0 0 GW2iIL 1 82 NewCAPS576 1 51 om 10 0 53 10 00 60 E9 00 64 CA 10 0 53 100 255 255 0 0 GW21E 1 85 TerminalSrv ver3 03 S om 10 0 57 57 00 60 E9 33 44 54 10 0 0 254 255 255 0 0 GW21S ME 1 2 ROMFS 1 2 om 10 0 70 26 00 60 E9 00 3D D0 10 0 0 254 255 255 0 0 GW26A 104 1 3 STOP Proxi A SOYAL 2 1 U om 10 0 71 111 00 60 E9 00 B4 D5 10 0 0 254 255 255 0 0 GW21S 256 1 45 NewCAPS576 V1 53 om 10 0 78 1 00 60 E9 00 B4 AE 10 0 0 254 255 255 0 0 GW21S 256 1 45 NewCAPS576 V1 53 om 10 0 151 71 00 60 E9 15 10 02 0060E9 151002 10 0 0 254 255 255 0 0 GW21S MAXI 2 0 Modbus Tcp 1 22 Port 50 om 10 0 151 99 00 60 E9 15 48 43 O060E9 154843 10 0 0 201 255 255 0 0 GW21C MAXI 2 0 TerminalSrv ver3 07 S om 10 0 154 31 00 60 E9 00 98 3D 0060E9 00983D 10 0 0 254 255 255 0 0 GW21S MAXI 2 0 TerminalSrv ver3 07 S om 10 0 154 37 00 60 B3 6F AA CE 0060B3 6FAACE 10 0 0 254 255 255 0 0 GW21W 2 0 TerminalSry ver3 07 AA om 10 0 154 52 00 60 E9 00 8B ED 0060E9 008BED 10 0 0 254 255 255 0 0 GW2IW M 2 0 NewCAP
5. Options the settings must match the COM port behavior expected by the PC application that will use this COM port The Configuration Wizard will recommend a combination of L Configuration Wizard COM4 IF Address of Server Fort Number 10 0 50 1 4660 imame Passion Test for presence of a modem connected to the server status Connected to Server COM Port Control Support Detected Telnet Protocol Detected Semion Completed COH Fart Gpion DIR dialed COH Fart Opon JSR Grace C Clg Fort Opto ACO grabit rien We Use Settings EB Copy israel E For Connection Protocol the setting must match the TCP IP protocol that the serial server o atop atop supports The Configuration Wizard is usually able to determine the correct setting settings 4 Start Writing Your Own Applications Before you start writing your host applications or programs to interact with GW51E MINI please make sure you have done the following 4 1 Preparing The System iP 2 Properly connect GW51E MINI hardware including power Ethernet and RS 232 cables Properly configure the parameters of GW51E MINI including connection type IP address gateway IP address and network mask accordingly see chapter 2 Hardware Installation section Configure GW51E MINI as TCP Server using default TCP port number 4660 configuration utility The host PC application program must be configured as a TCP client and connects
6. fields be aware that password is case sensitive Security e Old Password Wes COMI New Password Ps Verified Password 2 Please input the old password in the Old Password field input the new password in the New Password and the Verified Password fields Then click on Save Configuration to update the password Note You can press the default button of product to reset password to the default value GON Setup Click on the COM1 link and the following screen appears Fill in COM1 parameter information under COM1 field then click on Save Configuration button to save the changes i Mia T O D Virtual COM l Enable Local Port 4660 Overview IP Filter l Enable Networking Source IP 0 0 0 0 Security COM1 l To configure COM port parameters Serial Interface RS 232 Alias Name Baud Rate 9600 D Parity ke None Odd z Even e Mark Space Data Bits C7bits 8 bits Stop Bits bit 2bits Flow Control None Hardware XonfxXoff Keep Buffer While Connecting Fe Enable Disable Packet Delimiter SE 2 Pe C Characters Ox ASCIl Code Ex 0x0d or OxOd0a Save Configuration Ee Server GW51E MINI eo a t O 9 en 3 5 Configuration set by Hyper Terminal console utility Power off GW51E MINI Set the switch from NORMAL to CONSOLE Use a PC to connect to GW51E MINI RS 232 port Power on GW51E MINI Open a Hyper Terminal pr
7. 5 3 3 CONFIGURATION SET BY MONITOR EXE UTILITY cccecceceeceeceeceeeeeeececeeeneeeeceeneeaeceeceeneeaeseeeeeaeeneeeeneenenennes 5 3 4 CONFIGURATION SET BY WEB BROWSER 5 3 5 CONFIGURATION SET BY HYPER TERMINAL CONSOLE UTILITY ceceeceececceceeceeceeneeeeceeeeeeeeaeeeeeeeneseeeeeneees 8 3 6 VIRTUAL COM Mon 9 3 6 1 Setup of a virtual COM Bel 9 3 6 2 Virtual COM communication 10 4 START WRITING YOUR OWN APPLICAT TIONS c ccccceceeeeeeeeeeeeees 12 4 1 PREPARING THE SYSTEM ugeet EE EE 12 4 2 RUNNING THE SAMPLE PROGRAM ceccecceceececceceeceeceececneceeceeceeeeeueneeaeseeseeseeaeseeseeaesaeseeseeneseeeeeneneeneees 13 5 DIAGNOSTICS EE 15 5 1 USE STANDARD TCP IP UTILITY PING COMMAND nr nrnr rrn rn rnnr renerne 15 5 2 USE MONITOR EXE CONFIGURATION UTILITY bBpROGpRAM nnr nren nnt 15 5 3 USE TCPTEST EXE oR TCPTEST2 EXE SAMPLE RROGRAM 16 APPENDIX A GW51E MINI SINGLE PORT SERIAL SERVER SPECIFICATIONS cccccccecececececeeeececececeneecececeeeneeseceaenensesececeaeeseneaeaeeenes 17 A T HARDWARE SPECIFICATIONS EE 17 A2 SO Te IC TION Sct een 18 APPENDIX B GW51E MINI CONNECTION PIN ASSIGNMENT 19 B LETON ON RIAS EE 19 B 2 RS 232 DB9 Connector Ae Elei EE 19 B 3 DBO Male to Male adapter pin OH essdead ee said ees Eed dia a aada e 20 APPENDIX C CONFIGURATION UTILI Y ee KKK NNN 21 C FRONTE GTI ge E A AA E ee 21 C 2 DETECT OPERATIONAL DEVICES c ccceccecceceeceececceeeeceeeeeneeuece
8. 6 108 H Pinging 10 060 30 100 with 32 bytes of data Reply from IR H JH LR bytes 32 timetifims ITTL 64 Reply from 168 868 360 168 bytes 32 time lt ilims TTL 64 Reply from IR H JH LR bytes 32 timetifims TTL 64 Reply from IR H JH LR bhytes 32 timetifims TTL 64 Ping statistics for 16 6 380 1080 Packets Sent 4 Received 4 Lost A CH loss gt Approximate round trip times in milli seconds Minimum Ams Maximum Bms Average Bms C gt ping IR H 28 Lu Pinging 180 80 30 100 wath 32 bytes of data Request timed out Request timed out Request timed out Request timed out 5 2 Use monitor exe Configuration Utility Program Use monitor exe configuration program that comes with the product CD or diskette to check on the status of GW51E MINI The status can be read from AP version column of the tool Status Descriptions S The system is configured as a TCP Server and not yet connected A The TCP Server and is connected User manual Version 1 0 ABLE Linko Single Port Serial Server GW51E MINI eo el t O 9 Technologies For example s means that COM1 is server mode and is not connected Kal monitor ver A Broadcast IP annie Ip Address MAC Address Gateway SubnetMask__ Model__ Kernel_ AP version om 0 x 9 0 00 60 E9 00 05 4B 202 39 254 249 255 255 0 0 1 7 ATOP Proxi Access V2 2 om 10 0 9 1 00 60 E9 00 4F E4 10 0 0 254 255 255 0 0 GW26A 104 1 41 ATOP P
9. Atop ABLELinke Single Port Serial Server GW51E MINI User Manual Version 1 0 2004 07 01 Tel 886 3 5508137 Fax 886 3 5508131 www atop com tw User manual Version 1 0 ABLE Linke Single Port Serial Server GW51E MINI Ba OD atOp IMPORTANT ANNOUNCEMENT The information contained in this document is the property of Atop Technologies Inc and is supplied for the sole purpose of the operation and maintenance of products of Atop Technologies Inc No part of this publication is to be used for any other purposes and it is not to be reproduced copied disclosed transmitted stored in a retrieval system or translated into any human or computer language in any form by any means in whole or in part without the prior express written consent of Atop Technologies Inc Published by Atop Technologies Inc 2F No 146 Sec 1 Tung Hsing Rd Jubei City Hsinchu 302 Taiwan R O C Tel 886 3 5508137 Fax 886 3 5508131 www atop com tw Copyright 2003 Atop Technologies Inc All rights reserved All other product names referenced herein are registered trademarks of their respective companies User manual Version 1 0 ABLE Linke Single Port Serial Server GW51E MINI e atop Contents T INTRODUCTION HEEN 3 Ek Ge EEN 3 eZ PP Le ATO ONIN NC E EE 4 2 HARDWARE INSTALLATION NNN NENNEN KANNER NENNEN KENNEN 4 3 SOFTWARE CONFIGURATION ee EN ENKEN 4 21 DEFAULT SE TINOS EEN 4 3 2 TCP IP boprhNuwpcn A INEEN ANEA A AAEE S
10. S576 1 54 om 10 0 168 24 00 60 E9 00 18 CB 10 0 0 204 255 255 0 0 GW27A 2 18 208DVS27A TCP M X SM om 10 0 210 1 00 60 E9 00 48 D4 10 0 0 205 255 255 0 0 GW231A 2 18 208DV S231A TCP M X SM om 10 0 210 2 00 60 E9 00 26 EC 10 0 0 205 255 255 0 0 GW231A 2 18 208D S231A TCP M X SM om 10 0 210 3 00 60 E9 00 26 FD 10 0 0 205 255 255 0 0 GW231A 2 18 208DVS231A TCP M X EM om 10 0 210 4 00 60 E9 00 17 2A 10 0 0 205 255 255 0 0 GW231A 2 18 208DVS231A TCP M X SM om 10 0 210 5 00 60 E9 00 26 CA 10 0 0 205 255 255 0 0 GW231A 2 18 208DVS231A TCP M X SM om 10 0 210 6 00 60 E9 00 17 20 10 0 0 205 255 255 0 0 GW231A 2 18 208D S231A TCP M NB Sk om 10 0 210 7 00 60 E9 10 17 29 10 0 0 205 255 255 0 0 GW231A 2 18 208DVS231A TCP M X SM om 10 0 210 8 00 60 E9 00 17 28 10 0 0 205 255 255 0 0 GW231A 2 18 208D S231A TCP M X SM om 10 0 210 9 00 60 E9 00 17 46 10 0 0 205 255 255 0 0 GW231A 2 18 208DVS231A TCP M X SM om 10 0 210 10 00 60 E9 00 17 1D 10 0 0 205 255 255 0 0 GW231A 2 18 208D S231A TCP M X SM H Figure C1 Main window of monitor exe utility program C 2 Detect Operational Devices You may do the following steps to detect devices currently available on the network 1 Start monitor exe utility program 2 Select an item from the Broadcast IP list 3 Specify a number in the Wishes box 4 Click on the Invite button This will display all the devices infor
11. art the program please type in the following command in the command line prompt TCPTEST2 IP_Address Port Number ini xi D Cis tcptest2 10 0 50 100 4668 TGP Test Program 2 Connecting to 16 86 560 168 Port 4668 643200Ha gt Wait to Connect Connect OK The command tcptest2 10 0 50 100 4660 brings you to connect to a TCP server of IP address 10 0 50 100 and port number 4660 the received data is displayed on the screen and the data typed in is sent to the TCP server of the designated port number You can also send binary data in hex format with a leading character P For example OO and FF represent ASCII code 0 and 255 respectively You can also use modem to connect to the serial server Command AT Oa sends standard AT command to the modem which in return responds with OK OD OA message to the host application Always use then Enter key to exit the program Technologies User manual Version 1 0 ABLELinke Single Port Serial Server GW51E MINI eo a t O L 5 Diagnostics There are several ways you can check on the status and availability of GW51E MINI 5 1 Use Standard TCP IP Utility ping Command From Windows Start menu select Run and type in ping lt serial Server IP address gt If the connection is established the Reply messages are displayed otherwise it will indicate Request timed out of VIN TS ystem Semi exe KE Copyright 1985 2006 Microsoft Corp C gt ping 16 60 3
12. e Property Default Value IP Address 10 0 50 100 Gateway 10 0 0 254 Subnet Mask 255 255 0 0 User Name Admin Password Null COM 1 9600 None 8 1 No flow control buffer disabled packet delimiter timer 2ms Link 1 Type TCP Server Listen port 4660 Filter 0 0 0 0 Virtual COM disabled User manual Version 1 0 ABLE Links Single Port Serial Server GW51E MINI Sal Op atOp NOTE Atop provides a default button to restore system settings including IP address gateway IP address and subnet mask etc to the defaults Press and hold the default button for 5 seconds till the server reboots 3 2 TCP IP Port Number Port number 4660 is default of GW51E MINI and is associated with serial port COM1 After your application program connects to the TCP port 4660 of GW51E MINI data being sent to this TCP connection from your application program are transparent to the COM1 of GW51E MINI Vice versa is also true 3 3 Configuration set by monitor exe utility Use monitor exe that comes with the product CD or diskette to configure the network parameters of GW51E MINI As you can see from the following picture you can change IP address gateway IP address subnet mask user ID and password of GW51E MINI from the utility For more details of the utility please refer to Appendix C Configuration Utility MAC addr 00 60 E9 00 57 25 IP address MARTIAL TC Auto IP GateWay ji 0 0 0 254 Mack 255 255 0 0 Config Now User ID admin Cancel Password
13. e White Blue White Brown White Brown White Brown Brown You can choose either 568A or 568B definition If you want to make a crossover cable you should use 568A and 568B definition respectively in each terminal of a UTP cable B 2 RS 232 DB9 Connector Pin Assignment TXD S SG Signal Ground O OS O Copyright 2003 Atop Technologies Inc All rights reserved Designed in Taiwan 19 24 User manual Version 1 0 ABLE Links Single Port Serial Server GW51E MINI Cal OD atOp B 3 DB9 Male to male adapter pin out 1 2 3 4 5 6 T 8 9 OO OO Jo Om P Go User manual Version 1 0 ABLE Link Single Port Serial Server GW51E MINI eo el t O 9 Technologies Appendix C Configuration Utility The configuration utility monitor exe comes with the product CD or diskette is the main utility program to demonstrate and configure GW51E MINI s settings C 1 Run the utility Start the program under Windows 95 98 NT 2000 environment and the following window appears Fh monitor ver2 5 8 x Broadcast IP Wishes fo Locate Reply IP Address MAC Address Subnet Mask _ Model 1 Kernel AP version om 10 0 9 0 00 60 E9 00 05 4B 202 39 254 249 255 255 0 0 1 7 ATOP Proxi Access 2 2 10 0 9 2 00 60 E9 00 13 52 202 39 254 249 255 255 0 0 1 6 ATOP Proxi Access 2 6 5 om 10 0 25 100 00 60 E9 45 00 23 10 0 0 254 255 255 0 0 GW21S MINI 1 15 TerminalSrvverl 01 S om SUMMER 00 60
14. eaeceeeeeneeaeeeeneesesaeseeseeaeseeeeeneeaeeseneenenenness 21 C3 CONFIGURE DEVICES EEN 22 User manual Version 1 0 ABLE Linke Single Port Serial Server GW51E MINI Agatop 1 Introduction Atop GW51E MINI Single Port Serial Server is a gateway between Ethernet TCP IP and RS 232 communications It allows almost any serial device to be connected to a new or existing Ethernet network The information transmitted by GW51E MINI is transparent to both host computers Ethernet and devices RS 232 Data coming from the Ethernet TCP IP is sent to the designated RS 232 port and data being received from RS 232 port is sent to the Ethernet TCP IP transparently In the computer integration manufacturing or industrial automation area the Atop GW51E MINI Single Port Serial Server is used for field devices to direct connect to Ethernet network Terminal Server main control program run in GW51E MINI transforms whatever data received from RS 232 to TCP port then connects devices to the Ethernet network via a single application program or multiple application programs Many control devices provide the ability to communicate with hosts through RS 232 however RS 232 serial communication has its limitations For one it is hard to transfer data through a long distance With Atop GW51E MINI it is possible to communicate with a remote device in the Intranet environment or even in the Internet and thus increases the communication distance dramatically F
15. ere is not as many as devices responding to your invitation the system repeatedly sends invitation until your request is fulfilled Reply Indicates the actual number of devices this utility program detected Retry Specify the number of times that an Invite request is re sent Locate Locate the specified device Reset Reset the selected device Config Configure the selected device Exit Exit this utility IP Address Indicate the IP address of the device that replied to your request e Leading tag stands for IP address collision possibly caused by duplicated IP addresses on the network e Leading tag stands for Mac address collision possibly caused by duplicated Mac addresses on the network MAC Address Indicates the MAC address of responding device Gateway Indicates the IP address of the gateway Subnet Mask Indicates the TCP IP network mask OS Indicates the OS version of the responding device AP Version Indicates the AP version of the responding device Model Indicates the model number of the responding device This field is only available for monitor exe version 2 0 and above
16. erver and enable virtual COM by putting a check in front of the Enable button then type in the local port number in the Local Port field as indicated in the following figure aAgatop ABLELink Ethernet Serial Server Overview Link To choose specific working mode for COM port Networking TCP Server Security Virtual COM Enable COM1 Local Port 4660 IP Filter Enable Source IP 0 0 0 0 3 6 2 2 Run Serial IP for ATOP program on monitoring PC In the Window Start Menu select the Serial IP for ATOP program group and select Serial IP for ATOP Configuration The configuration window is shown as following merial l F for 4 TO F 4 O4 reen i sotfttvvare gt IF Address of Server Fort Number Configuration Wizard Credentials Ce Wo Login Required C Use Windows Credentials C Prompt at Login Front Naw C Use Credentials Below seni E Esssword Po COM Port Options T DTE is modem escape T DSR always high T DCD always high Restor Failed Connections elect Ports Fort Monitor Licensing lose Help About User manual Version 1 0 ABLE Linke Single Port Serial Server GW51E MINI Ba OD atOp At right is a sample Virtual COM Control Panel window At the left is the list of the COM ports that you have selected in the Select Ports window for use by the Virtual COM Redirector If you wish to change ports appeared in this lis
17. h Memory e 128K Bytes SRAM e 16K Bytes EEPROM e 512 Bytes Watch Dog Timer e 1 02 second hardware auto reset Serial Port e One serial port Communication Connector DB9 Female cable TxD RxD RTS CTS GND e Parameters 1 Baud rate 1200 bps 115000 bps 2 Parity None Even Odd Mark Space 3 Data bits 7 8 4 Stop bits 1 2 5 Flow Control Hardware CTS RTS Software Xon Xoff Please note the communication will not be established if parameters are set as 1 Parity None 2 Data bits 7 3 Stop bits 1 Power Requirement e 5 0 Vdc 200mA Temperature e Operation range UC to 60 C e Storage range 20C to 85C Humidity e 20 90 non condensing Dimension s 40 0mm X 77 6 X 23 0 mm Material e Metal housing User manual Version 1 0 ABLE Links Single Port Serial Server GW51E MINI Bai UH atOp A 2 Software Specifications Item Specifications Protocol TCP IP HTTP ICMP BOOTP Configuration e Configuration information for both TCP IP and serial ports is kept in the EEPROM e Configuration utilities of Windows 95 98 NT are provided for configuring settings e Ethernet web browser e Virtual com driver mode User manual Version 1 0 Ka ABLE Linke Single Port Serial Server GW51E MINI atop Technologies Appendix B GW51E MINI Connection Pin Assignment B 1 Ethernet Port RJ 45 1 Category 5 UTP cable 8 core wire 2 RJ45 Connector G 3 RJ45 Pin Assignment Ee eS ee Pn Blu
18. lexible configuration options enable this unit to be setup remotely over Ethernet web browser or Window utility 1 1 Packaging Atop Ethernet Serial Server x 1 Atop Ethernet Serial Server quick start guide x 1 Power adapter AC 100 240 to DC 5V x 1 Product CD containing configuration utility and sample programs x 1 Technologies User manual Version 1 0 S ABLELinko Single Port Serial Server GW51E MINI d t O 9 1 2 Application Connectivity GW51E MINI supports two connection modes i e TCP server mode and Virtual Com server mode Each link mode is fit to deferent applications Destination IP 10 0 50 100 2 Destination Port 4660 Ethernet We TCP Server 1P 10 0 50 100 d Listen port 4660 2 Hardware Installation Plug in DC 5V 200mA and the RUN LED will blink if GW51E MINI functions normally Prepare necessary cables hub power cord and RS 232 connector Connect a serial device to a serial port of GW51E MINI make sure the right connection of RS 232 Use monitor exe configuration utility in the product CD or diskette to diagnose GW51E MINI If it starts up successfully you are able to find the IP and MAC addresses of GW51E MINI You can change the network parameters of GW51E MINI to join your LAN by changing its IP address gateway IP address and subnet mask 3 Software Configuration 3 1 Default Settings Atop GW51E MINI Single Port Serial Server is shipped with default settings shown in the Following tabl
19. mation you have requested Copyright 2003 Atop Technologies Inc All rights reserved Designed in Taiwan 21 24 User manual Version 1 0 ABLE Linko Single Port Serial Server GW51E MINI eo aA t O 9 Technologies C 3 Configure Devices You may use monitor exe configuration utility to configure the settings of devices on the network To do so please follow the steps below 1 Repeat the steps in the section of C 2 to bring up the devices information 2 Select the device you want to configure from the IP Address column click on the Config button a configuration window will popup as shown in Figure C2 IP Address MAC Address SubnetMask Model 1 Kernel AP version om 10 0 9 0 00 60 9 00 05 4B 202 39 254 249 255 255 0 0 1 7 ATOP Proxi Access 2 2 om 10 0 9 2 00 60 E9 00 13 52 202 39 254 249 255 255 0 0 1 6 ATOP Proxi Access 2 6 5 om 10 0 25 100 00 60 E9 45 00 23 10 0 0 254 255 255 0 0 GW21S MINI 1 15 TerminalSrvverl 01 S om SCRE 00 60 E9 00 B7 25 10 0 0 254 255 255 0 0 GW21S MINI 1 15 TerminalSrv vert Di S om 10 0 50 98 00 60 E9 00 B4 AF 10 0 0 254 255 255 0 0 GW21S 256 1 45 NewCAPS576 V1 53 om 10 0 50 100 00 60 B3 6F AA CC 0060B3 6FAACC 10 0 0 254 255 255 0 0 GW21W 2 0 TerminalSrv ver3 07 SS om 10 0 51 100 00 60 E9 00 51 50 10 0 0 254 255 255 0 0 GW21S ME 1 1 ROMFS V1 1 om 10 0 53 1 00 60 E9 00 5E A8 10 0 0 254 255 255 0 0 GW2IL 1 82 NewCAPS576 1 51 om 10 0 53 10
20. ogram from your computer Start menu gt Programs gt Accessories gt Communication gt Hyper Terminal set COM2 parameters as follows Baud rate 9600 bps GE oe Een Data bit 8 bits Parity None Stop bit 1bit Flow control None Note At present time baud rate is fixed at 9600 bps for console port communication RS 232C parameters of your computer COM port and GW51E MINI must be the same 6 Once Hyper Terminal is connected type in username and password then the following Hyper Terminal window appears The default username and password are atop03 and admin800 Atop HyperTerminal File Edit View Call Transfer Help la aA dn e Input Password Hardware Testing Setup IP setup Netmask Setup Gateway ESC to return menu gt gt Connected 0 00 17 Auto detect 9600 SN User manual Version 1 0 a ff ABLELinko Single Port Serial Server GW51E MINI eo a O 9 Technologies 3 6 Virtual COM Mode Virtual COM driver mode for windows converts COM data to LAN data to control the RS 232 port on a GW51E MINI via the LAN By creating virtual COM ports on the PC Atop Virtual COM redirects the communications from the virtual COM ports to an IP address and port number on a GW51E MINI that connects the serial line device to the network The following figure is Atop Virtual COM connection diagram PC 0 000000 oo UB OOO p CG Serial Line Physical COM1 E Serial Line j ee e e
21. roxi A SOYAL 2 0 0 U om 10 0 9 2 00 60 E9 00 13 52 202 39 254 249 255 255 0 0 1 6 ATOP Proxi Access 2 6 5 om 10 0 21 100 00 60 E9 11 11 11 10 0 0 201 255 255 0 0 GYW21S MINI 1 14 TerminalSry verl 15a_ S om 10 0 21 121 00 60 E9 00 5E 2D 10 0 0 254 255 0 0 0 GW21L 1 85 TerminalSry ver3 04 Gi om 10 0 22 23 00 60 B3 76 FF 22 10 0 0 205 255 255 0 0 GW23J 1 12 DYSJ 1 12x om 10 0 22 28 00 60 E9 00 1 4 A4 10 0 0 10 255 255 0 0 GW27 2 18 207DY S27A TCP M NB SM TCP 224 0 0 1 om 10 0 23 33 00 60 E9 00 6C B2 192 168 0 1 255 255 0 0 GW21L 1 85 TerminalSry ver3 04b SS om 10 0 50 1 00 60 B3 6F AA CC 10 0 0 254 255 255 0 0 GW21W 1 46 TerminalSry ver3 04a 55 om 10 0 50 100 00 60 E9 00 90 31 10 0 0 254 255 255 0 0 GW21C MAXI 1 52 TerminalSry ver3 04 om 10 0 50 101 00 60 E9 00 90 38 10 0 0 254 255 255 0 0 GW21C MAXI 1 52 ermina ry vers U4 5 3 Use TCPTEST EXE or TCPTEST2 EXE Sample Program Use sample programs TCPTEST EXE and TCPTEST2 EXE that comes with the product CD or diskette to check on the status of GW51E MINI Please refer to chapter 4 2 to run the sample programs Copyright 2003 Atop Technologies Inc All rights reserved Designed in Taiwan 16 24 User manual Version 1 0 ABLE Linke Single Port Serial Server GW51E MINI Psatop Appendix A GW51E MINI Single Port Serial Server specifications A 1 Hardware Specifications Specifications SCH e 8 bit Embedded CPU e 50MHz Flas
22. t use the Select Ports button Each COM port has its own settings When you click on a COM port the Control Panel display changes to reflect the settings for that COM port Note When you change settings for a COM port the changes are effective immediately There is no separate confirmation dialog to confirm or cancel your changes Configuring Virtual COM Ports You configure each Serial IP COM port as follows i 2 2 Select a COM port in the list For IP Address of Server enter a numeric IP address for the serial server For Port Number enter the TCP port number that the serial server uses to provide its serial ports to the network For Server Credentials the default is No Login Required If your serial server does require a login by the Virtual COM Redirector the Virtual COM Redirector needs to provide a username and or password every time an application tries to use the serial server Click the Configuration Wizard button and then click the Start button that appears in the wizard window This important step verifies that the Virtual COM Redirector can communicate with the serial server using the settings you have provided If the Log display does not show errors click the Use Settings button in the wizard which makes the recommended settings effective and returns you to the Control Panel to continue with the following steps User manual Version 1 0 ABLE Link Single Port Serial Server GW51E MINI 6 For COM Port
23. to GW51E MINI with designated TCP port number 4660 for COM Make sure GWO51E MINI is running by checking the running status through monitor exe User manual Version 1 0 ABLE Linko Single Port Serial Server GW51E MINI Ba OD atop 4 2 Running The Sample Program Sample programs written in VB and VC included in package are provided for your reference source codes are also included Test program can be found in the product CD or diskette under the directory of sample vb_ap and sample vc_ap respectively There are two test programs TCPTEST written in Visual Basic and TCPTEST2 written in Visual C TCPTEST in Visual Basic This sample program is written in Visual Basic 5 0 with Winsock Controls It shows you how to send and receive data between host PC and GW51E MINI via Ethernet in two socket ports Run Visual Basic and open sample program tcptest vbp after the program is started successfully you can start testing functions For more information please press Help in the program to get detail explanation Note Please be sure the Microsoft visual studio family software is installed on the computer Otherwise the sample program will not run iw TPP Convertor Sample Program 12 19 22 TCP connect ok 12 19 34 TCP Sending 19 19 34 TCP Send ok Status User manual Version 1 0 if ABLELinko Single Port Serial Server GW51E MINI Bai OD a We par Technologies M TCPTEST2 in Visual C To st
Download Pdf Manuals
Related Search
Related Contents
Cleopatra - La Nordica Skwirrel II - Minicrosser SENSOR ELETROMECÂNICO PARA SÓLIDOS ResaForm - Manuel d`installation v1.0 Istruzioni per l`uso 可動間仕切収納LDKタイプリーフレット - ce Copyright © All rights reserved.
Failed to retrieve file