Home

User manual ComBi-D3 - SaluTron Messtechnik GmbH

image

Contents

1. your choice and exits the menu cSt Resetting the average value mean of the measurements YES Yes no no GAG Choice of substrate material AUT automatic detection recommended indicated by AUTO icon in the display FE only steel or iron nFE non magnetic metals aluminum copper etc Cal continuous measurement indicated by CONT icon in the display On On OFF Off Unf Choice of measuring unit between microns mm and mil 25 4 um mm 1 00 mil bEP Switching on or off of tons keys On On OFF Off Sn Displays the serial number of the device Automatic detection for the measurement on ferro or non ferro The automatic detection of subsurface material Fe ferro or NFe non ferro is indicated by the AUTO icon in the display Before each measurement the device checks the material and selects the corresponds measurement method If the device is placed on magnetic material ferro Fe icon is indicated in the display By measurements on non magnetic metals non ferro nFe icon is indicated in the display The GAG option of the menu enables or dis ables the automatic detection Display of the average value mean and the number of measurements The device calculates with each measurement and without storing of individual results the average value The display of mean is due to the short press less than 3 seconds of the ON OFF button and is indicated with Ave average icon in th
2. User manual Coating thickness gauge SaluTron ComBi D3 Salu 7ron Messtechnik GmbH Max Planck Str 62 D 32107 Bad Salzuflen Tel 49 5222 959760 Fax 49 5222 50499 www salutron de info salutron de Congratulations on the purchase of our coating thickness gauge ComBi D3 Description The ComBi D3 is a simple and cost effective measuring device It belongs to a range of non destructive coating thickness gauges Measuring ability of ComBi D3 Fe all non magnetic on steel or coatings such as iron synthetics lac quers enamels copper chromium zinc etc NFe all isolating coat ings such as lac quers synthetics enamels paper glass rubber etc on copper alu minum or brass This includes an odized coatings on aluminum as well It is easy and handy to use and allows the user to make all necessary adjustments with the aid of a menu MODE button This allows for change to be implemented quickly and simply The gauge ComBi D3 can be used for a wide variety of applications and has to offer a large measuring range from 0 to 3 5 mm Modern electronic and the robust casing guarantee an extended lifetime for the high precision instru ments Battery exchange The ComBi D3 gauge is powered by a 9 V al kaline battery The battery compartment can be found in the top back portion of the instrument If a battery icon appears in the display the bat tery has to be exchanged If a replacem
3. e display If the ON OFF button is short pressed again the number of last measurements applied to the mean together with n icon appears in the display The r Sf option of the menu resets these values Delivery gt gt Coating thickness gauge ComBi D3 Carrying case with two zero plates steel and aluminum 9 Volt battery alkaline user manual Technical Specifications Base material substrate steel or iron Non magnetic metals such zinc copper brass aluminum stainless steel anodized aluminum Continuous measuring range Display of measured values Display resolution Repeatability basic tolerance Minimum object size Minimum curvature convex concave Minimum substrate thickness Fe NFe Temperature range Storing Operating Probes Power supply Dimension LxWxH Weight incl battery Fe NFe 0 3 500 um or 0 140 mil from 0 0 999 in um from 1 00 3 50 in mm or from 0 00 140 mil 0 1 um in the range of 0 0 99 9 um 1 um in the range of 100 999 um 0 01 mmin the range of 1 00 3 50 mm or 0 01 mil in the range of 0 00 9 99 mil 0 1 mil in the range of 10 0 99 9 mil 1 0 mil in the range of 100 140 mil 1 5 um 2 from 0 1000 um 3 5 from 1 00 3 50 mm 10 x 10 mm or 0 4 x 0 4 5 mm or 0 02 30 mm or 1 0 20 mm or 8 mil 0 05 mm or 2 mil 10 C to 60 C 14 F to 140 F 0 C to 60 C 32 F to 140 F Single po
4. ent battery is not available imme diately several measurements can still be taken until the gauge shuts down completely the display shows bAF and a discontinuous beep tone is audible Attention Exhausted batteries are hazardous waste Used batteries not with the domestic waste decontaminate but deliver at stated col lective places Switching on and off of the device gt The gauge can be switched on manually via pressing of ON OFF button or by di rectly placing the probe on the measure ment object gt It appears Cd3 name of device and then the last measured value gt The gauge switched off automatically after 40 seconds of non use or by long pressing about 3 seconds of ON OFF button Handling and storage The ComBi D3 gauge is a high precision instru ment with a wide scope of applications It is therefore of great importance that the device is handled with care to ensure a long life and a prerequisite for precise and accurate measure ment results The following guidelines are to be followed to achieve the above gt Protect the device from dust and dirt gt Donot drop the device to the floor gt Protect the device from moisture aggres sive vapors and chemicals gt After use please put the device in the carry ing case gt Avoid direct strong sunlight and tempera ture shocks as these can have a negative influence on the measurement result gt Precise measurement results can be achieved
5. er switching on by different measurement pro cesses inserting of new battery or after pro longed use Place the device on the iron or the aluminum plate in the carrying case You can also use a piece of uncoated ferro Fe or non ferro NFe metal substrate used in your process If the displayed value is out of the basic tolerance the instrument has to be zeroed The following steps are to be taken to zero the gauge gt Remove the device from the zero plate or the substrate gt Press the Zero button The display shows P0 0 zero point gt Place the gauge on the zero plate or the substrate Pln infinity appears followed by a beep tone gt Lift the device at least 5 cm from the zero plate 0 0 appears followed by another beep gt To check the zeroing place the gauge on the zero plate or the substrate again 0 0 should appear on the display followed by beep If the result is different repeat the ze roing procedure gt The device is now ready for accurate mea surements Note that it is not necessarily to receive the same displayed result by repeated measurements at the same location Measurement variations can be caused by roughness dirt or bumps The menu of ComBi D3 The various options from the menu can be accessed by repeatedly pressing the Mode button Pressing the Enter key allows to select the displayed option Now the Mode button change or select the setting Pressing of Enter confirms
6. int 9 Volt E block alkaline 118 x 58 x 38 mm or 4 6 x 2 3 x 1 5 approx 150 g or 5 3 oz The ComBi D3 corresponds national DIN and international ISO BS ASTM standards and have the CE mark DIN 50981 50984 ISO 2178 2360 2808 BS 5411 3 11 3900 c 5 ASTM B499 D1400 Technical data subject to change without notification Stand 03 2014
7. only with a clean probe Therefore use regularly a clean damp cloth gt Check the probe regularly for soiling such as paint or iron particles gt Ifthe device is not used for a long time it is advisable to remove the battery to avoid possible damage caused by the leakage of a battery gt Ifthe device has a failure contact your sup plier for help Taking measurements gt Hold the device vertically on the location to be measured Place the probe flat avoid tipping To get the best results place the thumb on the elliptical indicated position with the other fingers behind the gauge for balance gt A beep is audible and the measured value appears on the display gt Improper placement as well as picking up the device before the end of the measure ment and the zeroing on a non metallic sur face substrate is displayed with Er0 error gt If the coating thickness exceeds the maxi mum range 3500 um or if the device is placed on the incorrect substrate wood paper cardboard etc the display shows InF infinite gt The V groove on the measuring head helps by measurements on round objects such as rods tubes shafts radii etc Please do not perform measurements on magnets and in magnetic fields Magnetic fields influence the results by the Fe and strong electromagnetic radiation has the influence by the NFe measurements Zero calibration A zeroing of the instrument is necessary aft

Download Pdf Manuals

image

Related Search

Related Contents

Russell Hobbs 21340-56  Europa  Dell OpenManage Server Administrator Version 7.1 Installation Manual  Impex MWB-500 Owner's Manual  IBM Network Advisor V12.4 delivers enhancements to support new    樹脂管バイ ススタンダー ド 取扱説明書  User Manual of DS-6101HFI  Manual de Instalación y Operación  千葉市物品検査要綱(PDF:692KB)  

Copyright © All rights reserved.