1. e Check if your faucet matches any of the installation alternatives below If not contact your dealer for further advice and recommendations Alternative A1 Faucet with outer thread 22 mm fig 6 4 Alternative A2 Faucet with inner thread fig 6 5 Alternative A3 Faucet with round pipe e with Rubber Insert 6 3 16mm fig 6 6 e without Rubber Insert 6 4 20mm fig 6 7 fig 6 3 e Connect the Diverter Valve with hose to the faucet according to the matching Alternative e For Alternative A3 use a screw driver to tighten the metal ring around the rubber fig 6 6 Installation 3 Connection of the Inlet Hose o Place the water purifier where it will be used a Determine the right length of the Inlet Hose and place it there where it does not get in the way e Cut the Inlet Hose to its proper lenght fig 7 1 o See to it that there are no folds in order for the water to flow freely Insert the Inlet Hose to the Speedfit Connector 15 fig 7 2 e Make sure it is fully inserted and locked when it is pulled 4 Turn on the water supply o Open the valve of the faucet Turn the handle of the Diverter Valve clockwise to horizontal position fig 7 3 e Check for any leakage 5 Turn off the water supply Close the Valve of the faucet e Check for any leakage e Turn the handle of the Diverter Valve counter clockwise to vertical position Alternative B Installation to wate
2. USER MANUAL amp English introduction Congratulations on your new water purifier Make sure thatthe User Manual accompanies the UV400 GLOW UV400 if it is moved resold or there is a change of owner so the user will always have access to the complete instructions The UV400 is designed for producing the water for and safety information drinking and cooking of a normal household For optimal function it is important that you read the The water source must either be from the municipal section entitled Safety Information on page 5 and that water system or well aimed for personal consumption yOu follow the installation instructions on pages 6 8 in detail It is designed to give you plenty of clean water in years to come if correctly used and maintained i We recommend that you refer to page 3 when reading the rest of this User Manual Therefore it is of the utmost importance to read the User All bracketed numbers refer to figures 3 1 Manual thoroughly and must be kept in a safe place for and 3 2 future reference Unpacking Examine the water purifier for any signs of damage and make sure that all accessories are included See fig 2 The following items should be included Water Purifier Adapter 12 V Wall Bracket Diverter Valve with hose External Faucet Adapter External Thread Insert and washer Angle Hose Connector 3 4 nut and washer 00000000 User Manual Should you discover any damag
3. V400 Maintenance Replacing the Carbon Block Filter Maintenance Replacing the UV Lamp Maintenance Replacing the Quartz Sleeve Maintenance Cleaning the Quartz Sleeve Maintenance Cleaning the Coarse Filter Regular Care Trouble Shooting Electrical Trouble Shooting Water Consumables Service Technical Data Company Information General The UV400 is an extremely safe water purifier However it is important that every user of this product is familiar with its use and safety features To prevent mishaps and problems read the Safety Information in this chapter thoroughly and carefully follow the Installation instructions on pages 6 to 8 e The water from the UV400 should only be consumed when the UV400 has been properly maintained and the UV monitor s Green Lamp 2 is lit Turn to pages 6 to 15 for Installation and Maintenance e Do not change or attempt to modify the UV400 This could result in personal injury and or damage to property These eventualities are not covered by any warranty e Once a month the connection should be checked for leakage Installations and service e Only install the UV400 in an upright vertical position e Only use those types of hose and connectors ap proved for full line water pressure when connecting the UV400 to its water source e Verify that the installation is approved by your insurance company e Included hose 12 should be used for the installation Usi
4. e faults or anything missing you should notify your dealer immediately Keep packaging material out of children s reach Guide to use the Manual The following symbols will be found in the text to guide you throughout the instructions Safety information A Hints and information i Description of the UV400 The UV400 purifies water through filtration and dis All features are operated with a one touch button The infection with UV light Blue Button 1 guided by the Green Lamp 2 and Red Lamp 3 on the control panel It requires e A water source with pressure e Voltage 100 V to 240 V 50 Hz to 60 Hz The socket fitting the Adapter 12 V 9 Control Panel 1 Push Button The Blue Button 6 Body e UV Lamp On 7 Bottom Cover e Water Flow Start and Stop 8 Filter Lock e Flush 9 Adapter 12 V e Auto Filling 10 DC Plug 2 Green Lamp Ready 11 Wall Bracket 3 Red Lamp UV Monitor 12 Diverter Valve with hose 13 External Faucet Adapter 14 External Thread insert and washer Other Parts 15 Speedfit Connector with 3 4 nut 16 Angle Hose Connector 3 4 nut and washer 4 Top Cover l Li 17 User Manual 5 Water Pipe Purifier Water Outlet 19 14 15 16 17 18 19 20 Introduction Description of the UV400 Safety Information Installation Inlet Hose to faucet with Diverter Valve Installation Inlet Hose directly to water pipe Installation Connecting the Adapter 12 V Flushing How to use the U
5. eak the UV Lamp p Hold the end of the UV Lamp metal cap when connecting and disconnecting the terminal s Never pull the wire s for detaching the terminals of the UV Lamp Disconnecting UV Lamp 1 Disconnect the DC supply to the UV400 2 Open the Top Cover with a coin by twisting it fig 12 1 3 Disconnect the terminal fig 12 2 by pulling it up at the same time holding the end tip metal cap of the UV Lamp 4 Pull up the UV Lamp carefully fig 12 3 5 Disconnect the bottom end of the terminal fig 12 4 Installing UV Lamp 6 First connect the bottom end terminal with white wires fig 12 5 by fitting the terminal to the two pins of the UV Lamp 7 Insert the UV Lamp with the connected bottom end terminal into the Quartz Sleeve fig 12 6 8 See to it that the UV Lamp is fully inserted 9 Reconnect the top terminal with blue wires to the two pins of the UV Lamp fig 12 7 10 Refit the Top Cover and push it down until it snaps in place fig 12 8 Make sure that no cables are squeezed 11 Re connect the DC supply Only use GLOW s original UV Lamp to ensure proper disinfection and function A different type of UV Lamp can harm the electronics which would not be covered by the warranty Do not touch the glass of the UV Lamp since finger prints can reduce UV transmittance 12 Maintenance Replacing the Quartz Sleeve Before replacing the Quartz Sleeve disconnect and remove
6. es per minute gt 2 bar Dimensions N36 x w12 x d19 cm Water supply temperature Minimum 2 C Maximum 44 C Recommended water source for normal Turbidity lt 1 FNU filter usage Chlorine gt 4 mg l Organic substances lt 1 mg l 19 Dealer The UV400 is developed and marketed by Glow AB Glow AB Kopparbergsvagen 6 SE 722 13 Sweden www glowinternational net Made in the E U 20
7. eve Holder and tighten the Quartz Sleeve holder fig 14 4 9 Insert and re connect the UV Lamp see instructions 6 to 11 on page 12 14 Maintenance Cleaning the Coarse Filter If the water supply contains a lot of sediments the Coarse Filter can get saturated J MA T i Before Cleaning the Coarse filter 1 Disconnet the DC Plug 10 of the UV400 2 Close the tap valve of the water supply to the UV400 Cleaning the Coarse Filter 3 Put the UV400 carefully on the side 4 Unscrew the hose connector from the Solenoid Valve fig 15 1 5 Grip the Coarse Filter with a small plunger and pull it out of the Solenoid Valve fig 15 2 6 Clean the Coarse filter with a brush and water fig 15 3 and push it back into the solenoid valve with a plier fig 15 4 7 Refit the water inlet hose 8 Open the tap to the water supply and verify that the water inlet connection does not leak 9 Connect the DC Plug to the UV400 15 Regular Care Things to Remember Frequency of descaling Listed are the things you need to remember for the i Calcium Ca Water hardness Period regular care and maintenance of your UV400 and od between every Magnesium German water descaling e Check the function of the Green Lamp 2 every time EYP RETE aT procedure the UV400 is in use standard mg l e Never leave the room with the Green Lamp flashing which means the UV400 will NOT automatically shut off since the
8. hing procedure fig 8 5 5 Release The Blue Button to stop the flushing The UV400 is easy to use Just press The Blue But ton 1 Thanks to modern and advanced electronics all features are controlled by the Blue Button with the guidance of the Green 2 and Red 3 Lamp The first push of the Blue Button 1 will activate the UV lamp in side the UV400 The Green Lamp will blink for about 20 Before operating the UV400 1 Be sure that the UV400 is connected to its water source and that the water pressure is on 2 Verify that the UV400 is connected to the DC Plug 10 and that the Adapter 12 V 9 is connected to the wall socket Normal Operation of UV400 Turn on the UV Lamp 1 Push The Blue Button 1 once to TURN ON the UV lamp fig 9 1 e The Green Lamp 2 should be blinking slowly for approximately 20 seconds the first time 5 seconds for following usage as long as the voltage supply is not disconnected fig 9 2 e When the Green Lamp stops blinking and stays lit purified water is ready to be drawn from the UV400 Draw and Stop Purified Water 2 Push the Blue Button one more time for DRAWING water fig 9 3 e The Green Lamp should now be blinking rapidly that the solenoid valve is open 3 Push the Blue Button one more time for STOPPING the flow of water e The Green Lamp should stay lit 4 Sequence 2 and 3 are repeated Reminder The Green Lamp and the UV light will shut off automat
9. ically after 30 seconds if not in use How to use the UV400 seconds before you can draw water During this period the UV lamp is preheated for optimum disinfection After this the Blue Button is used for opening and closing the water flow The UV400 will automatically shut off when it is not in use the solenoid valve is not opened for ap proximately 30 seconds How to use the UV 400 With the Auto Filling feature you can draw the desired during 30 seconds This is very practical since you can amount of water in multiples of 0 5 amount of water do other things while filling up your pitcher or container Before using the Auto Filling function the UV400 should be in ready mode UV Lamp should be lit Auto Filling 1 Push the Blue Button 1 and keep it down while ob serving the following e That the Green Lamp 2 blinks slowly e And is constantly lit fig 10 1 2 Release The Blue Button when the desired number of flashes is reached Each flash corresponds to 0 5 gt 2 bar and new filters Examples 3 flashes correspond to 3 x 0 51 1 5 5 flashes correspond to 5 x 0 51 2 5 Make sure that your container is big enough for the desired amount of water Never leave the room when drawing water from the UV400 Always make sure that the water really stops before the container overflows 10 Maintenance Replacing the Carbon Block Filter The Carbon Block Filter has to be replaced when e The wa
10. location e The UV400 is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowldege unless they have been given supervision or instruction concerning use of the UV400 by a person responsible for their safety Children should be supervised to ensure that they do not play with the UV400 Installation Please read the Safety Information on page 5 before the installation of the UV400 The UV400 must always be installed for usage in the Your dealer can help you with the most suitable vertical upright position It can be used as a table top installation and provide you with needed accessories appliance and or mounted on the wall whatever is most practical The UV400 can either be connected to a faucet or to a water pipe Installation of Inlet Hose 1 Choose a dry area near the kitchen sink 2 Decide what type of installation and water connection e Wall mounted fig 6 1 with Wall Bracket 11 and or table top fig 6 2 e Type of water connection Alt A to faucet with Diverter Valve fig 6 2 Alt B to water pipe fig 7 4 o The UV400 should not be installed more than 1 8 meters away from an electrical outlet within reach of the connection of the DC Adapter 12V Alternative A Installation to faucet with Diverter Valve fig 6 2 fig 6 2 e Before installation always remove strainer from the tap if applicable fig 6 3
11. ng the UV400 e The UV400 is designed to produce water for drinking and cooking for a normal household e The UV400 must never be used without the Carbon Block Filter except during the descaling procedure e Never block the Water Pipe 5 of the UV400 e Never connect a hose to the Water Pipe since it can accidentally get folded and cause damage to the UV400 This kind of damage is not covered by any warranty Safety Information A e Ifthe UV400 is malfunctioning disconnect the adapter from the wall socket e The water supply to the UV400 must have a normal temperature between 2 C and 44 C If the water supply to the UV400 could be unfit for human consumption the purified water from the UV400 should be tested and approved for consumption The tests should be carried out once a year e Only use the original 12 V adapter Use the Adapter 12 V 9 in normal room temperature and avoid direct sunlight e The UV400 should not be installed in any location where the temperature can fall below 2 C 35 F e TheUV400 is compact and heavy for its size especially when filled with water Thus it should be handled with care to avoid dropping it that would cause damage of the UV400 Old hoses should be replaced by the new included hose 12 e Never install an ice machine or any appliance to the UV400 Water Pipe 5 Use only original spare parts recommended by GLOW e Always connect the Adapter 12 V 9 to a socket ina dry
12. or and Green Over Current Protection Lamp Ready are flashing together e The room and water are too cold below 4 degrees Avoid cold water or areas UV Lamp terminal electrically shortcut by water Check if the end of the UV is wet Check if the Quartz Glass Sleeve has water inside The Lamp does not light up nothing happens You press the Blue Button too quickly The unit is not properly connected to the electrical source Incorrect Adapter 12 V UV Monitor Red Lamp and Ready Incorrect voltage Green Lamp are flashing You might use wrong 12 V adaptor Only use original spare parts and consumables 17 Trouble Shooting Water If the water which comes out of the unit is of poor quality or if the unit is leaking Symptoms Warnings If no or only a little amount of water comes out of the UV400 despite the Green Lamp flashing Solenoid Valve being open Is the water on and the pressure high enough Is the Carbon Block Filter old and or saturated If so replace filter Is the Coarse Filter clogged Clean it Water leaks from the UV400 Is the Bottom Cover tightened Is the Sleeve Holder tightened Is the inlet hose to the purifier connected properly Bad smelling water Has the unit not been used for a long period Run the UV400 for at least 5 minutes Dispose the water Let the UV400 run for about 10 minutes before initial use Is the Carbon Block Filter old The activated carbon effect might have been de
13. pleted After a new filter is installed the UV400 may drip The UV400 drips before all air has disappeared This normally disapears after a few minutes of use No Carbon Block Filter is used Install a new one Old Carbon Block Filter is used Replace it Consumables Spare parts If the UV400 does not work properly we recommend that you start to use the Trouble Shooting see page 17 and page 18 before calling for service Contact your authorised dealer for consumables and spare parts The filter is the part which normally has to be relplaced reguraly for proper function Carbon Block Filter 18 We also recommend that you always keep an extra Carbon Block Filter available if it needs to be replaced The UV Lamp and Quartz Sleeve rarely need to be replaced However certain conditions might damage them Spare Parts UV Lamp Quartz Sleeve Service Technical Data Service Before calling service take down notes of the problem of your UV400 For easy and faster support note down the product no and serial no For service and spare parts please contact your authorized dealer Technical Data Power Supply to 12 V Adapter 100 V to 240 V 50 Hz to 60 Hz Power Supply to Water Purifier 12 V DC stabilized Only use original adapter Power Consumption with Adapter 12 V Max20W included when pouring water Water line pressure 0 5 bar 8 bar Weight without water approximately 2 7 litr
14. r pipe fig 7 4 Since the GLOW UV400 works with a Solenoid Valve it can be directly installed to the water pipe This is a more permanent installation and GLOW UV400 s automatic features can be enjoyed to its full capacity It is recommended to contact your authorized dealer for assistance for this type of installation i Disconnection of the hose fig 7 5 fig 7 5 In case you need to disconnect the hose from the installed water purifier do the following e Make sure that the water is OFF no water pressure in the hose e Push the locking ring highlighted against the housing arrow A at the same time pull out the hose arrow B Installation Connecting Adapter 12 V Flushing Connecting the Adapter 12 V 1 Connect the DC Plug 10 to the UV400 fig 8 1 2 Connect the Adapter 12 V 9 to the electrical socket in a dry location Flushing Procedure The UV400 should be flushed e after installation of the UV400 e after replacement of filter e Descaling Procedure Never consume the flushed water During the flushing the UV Lamp is not lighted which means that the water does not get sterilized 1 Disconnect the DC Plug fig 8 2 2 Push The Blue Button 1 and keep it pressed fig 8 3 at the same time as the DC Plug fig 8 4 is reconnected 3 After a short time the Solenoid Valve will open and water will enter the UV400 4 Keep The Blue Button pressed down during the entire flus
15. solenoid valve is open e Check weekly that all connections to the UV400 are properly sealed 50 100 o rr ameme e Always unplug the UV400 if it is not used for a long time 100 140 14 20 1 month e Always carry out the descaling procedure regularly e If the water supply has been classified as unfit for drinking the water from the UV400 should be tested frequently e Avoid installing the UV400 in a hot or cold area or where it is exposed to direct sunlight e Never connect an equipment or a hose to the water outlet of the UV400 The Carbon Block Filter needs to be replaced when the water flow has been reduced to half compared to when the filter was new or every 6 months For an immediate shut down of the UV400 simply disconnect or unplug the adapter Never pour water over the water purifier or dip it in water A Never let the Adapter 12V get wet Never clean the adapter with a wet or damp cloth 16 Trouble Shooting Electrical The UV400 has several built in safety features indicated by the Red and Green Lamp on the Control Panel Symptoms Warnings UV light and disinfection assurance e If the UV Lamp is damaged replace the UV Lamp e If the UV Lamp is not properly connected Assure that the UV Lamp terminals are properly fitted to the pins of the UV Lamp Red Lamp UV Monitor 3 shines steadily e If any wires have gotten detached from the UV Lamp terminal s Red Lamp UV Monit
16. ter flow has been reduced to about half of its full capacity e It has been in use for 6 months 1 Disconnect the DC Plug 10 from the water purifier 2 Place the UV400 near a water outlet normally the kitchen sink and be prepared for water to come out 3 Open the Bottom Cover 7 by turning it counter clockwise fig 11 1 and pull it out together with the attached Carbon Block Filter fig 11 2 4 Be prepared for excess left over water to come out 5 Clean the inside of the Filter Chamber with a small brush and rinse with clean water 6 Press the lock located at the center of the Bottom Cover towards the direction as shown in fig 11 3 7 Detach the old Carbon Block Filter and insert the NEW Carbon Block Filter into the Bottom Cover Make sure that the rubber seal is properly fitted as shown in fig 11 4 Lubricate the rubber seal with any vegetable oil for easier fitting when tightening the Bottom Cover fig 11 6 8 Push the Filter Lock 8 back to the center of the Bottom Cover fig 11 5 9 Insert the Bottom Cover with the NEW attached Carbon Block Filter and tighten the Bottom Cover clockwise fig 11 6 9 Flush the UV400 for 5 minutes before using it again See Flushing Procedure on page 8 11 Maintenance Replacing the UV Lamp It is rare that the UV Lamp has to be replaced since the UV400 has a shut off timer However certain conditions o ages might cause damage or br
17. the UV lamp Refer to fig 12 3 in Replacing the UV Lamp on page 12 1 Unscrew the Quartz Sleeve Holder fig 13 1 2 Pull out the Old Quartz Sleeve together with the O ring fig 13 2 3 Insert the new Quartz Sleeve with the O ring fig 13 3 4 Fit and screw the Quartz Sleeve Holder and tighten the Silicon O ring hard fig 13 3 If the Quartz Glass is broken replace it immediately Make sure that there are no remaining shards of glass from the Quartz Sleeve in the UV chamber Broken Quartz Sleeve should be kept away from children s reach and disposed of appropriately 13 Maintenance Cleaning Descaling the Quartz Sleeve 1 Disconnect the DC plug 10 2 Remove the UV Lamp see page 12 Follow instructions 1 to 5 3 Unscrew the Quartz Sleeve Holder fig 14 1 4 Pull out the Quartz Sleeve together with the Silicon O ring fig 14 2 Be careful not to drop or damage the Quartz Sleeve 5 Prepare a solution of water and vinegar for cleaning and descaling of the Quartz Sleeve 6 Weta clean cotton cloth with the water and vinegar solution 7 Gently rub the outside surface of the Quartz Sleeve with the wet cloth cleaning it thoroughly fig 14 3 Make sure that the inside of the Quartz Sleeve AN does not get wet This could later short cut the UV Lamp Avoid touching the Quartz Sleeve directly with the fingers below the Silicon O ring 8 Insert the newly cleansed Quartz Sle