1. 1 Powering On The Unit 1 First Time Users and Initial Test 1 Tab 3 Connector Panel m 2 Electrical Symbols 3 Tab4 3 Image Adjustments 3 Brightness E 3 Kontrast e RR 3 Backlight 3 Tab 5 Menu Systems Overview 4 Video Source 5 Display Set Up nnn nnn 6 SD SDI Picture Menu m 6 S Video Picture Menu 6 Composite Picture Menu 6 VGA RGBS Picture Menu nnn nnn nnn nnn n nnn nnn 7 YPbPr Picture Menu 7 DVI Digital Pictu
2. or B button to increase or decrease brightness Setting the brightness too high or too low will decrease the amount of visible grayscales Press the Brightness Contrast button twice to display the Contrast control Press the lt or B button to adjust the contrast Setting the contrast too high or too low causes loss of some grayscales Color saturation may appear incorrect Press the Brightness Contrast button three times to display the Backlight control Press the lt or button to set the backlighting Note Lowering the backlight level will increase the backlight lifetime Menu Systems Overview Press the MENU button once to open the Menu System The current video input and its resolution are shown in the Display Mode tab on the top right of the menu The Menu System opens with Picture menu displayed Press the lt or B button to select the menu you want to work with then press the SCROLL button to select the parameter Press the 4 or B button to set the parameter to the desired value Press the MENU button to save your changes and close the Menu System Notes 1 All parameter names change to the language selected in the Setup Menu 2 Grayed out parameters are not accessible Composite Horizontal Posibon 18 20 22 24 26 Video PACS Vertical Position o 5500 6500 8000 9300 User O ca Scaling EN omart5ync 9 A
3. s resolution range Setting Frequency Phase and Sharpness Windows Users Open a WordPad document and set the font to Arial 8 Press the enter key to move the cursor to the middle of the page Hold the shift and keys down to create a line of s If the signs appear in groups of light or dark then the Frequency is not correct Press the MENU button to open the OSM then SCROLL to the Frequency parameter Press the or buttons to increase or decrease Frequency There will be a point were all the signs snap into focus and are the same intensity Phase and Sharpness are subtle adjustments and are best set using a display calibration program 12 Drawing and Dimensions bl BB M X SERIAL HD SD4 EY DC DVI ROBS YOARGBS S VIDEO COMP OC N L _ O m DETAIL 13 Data Connectors and Pin Outs VGA RGBS 1 RED 6GND RED 11 IDO 2 GREEN 7GND GREEN 12101 3 BLUE 4102 8 GND BLUE 13 HORIZ SYNC 10 SYNC GND 15 ID3 5 GND Pin Description Serial Control Pin Description NC No Connection NoConnection 8 NC NoConecion 3 _9 RxD Flash Upgrade Receive Data DVI I Digital amp Analog am Os EEEENEN be DVI I supports digital and analog RGBS YPbPr Analog data appear on pin 8 and pins C1 through C5 Compliant with DVI 1 0 T M D S DATA 2 HOT PLUG DETECT T M D S DATA 2 T M D S DATA 0 T M D S DATA 2 4 SHIELD T
4. and 2 this device must accept any interference received including interference that may cause undesirable results 1 Use the attached specified cables with the color monitor so as not to interfere with radio and television reception Use of other cable and adapters may cause interference with other electronic equipment 2 This equipment has been tested and found to comply with the limits pursuant to FCC part 15 and CISPR 11 This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications IEC This equipment has been tested and found to comply with the limits for medical devices to the IEC 60601 1 2 2001 These limits are designed to provide reasonable protection against harmful interference in a typical medical installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to other devices in the vicinity FCC Council Directives of European Standards and IEC There is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient o
5. Device Directive 93 42 EEC general safety information This monitor complies to the above standards only when used with the supplied medical grade power supply Power Supply SL Power Electronic Corp MW155RA2400F02 AC Input 100 to 240 Volts at 50 to 60 Hz DC Output 24 volts Power Cord Use a hospital grade power cord with the correct plug for your power source The monitors should be powered from a center tapped circuit when used in the US at voltages over 120 volts Monitor is intended for continuous operation This display is energized from an external electrical power source for class 1 equipment It is the responsibility of the installer to test the display s earth ground to verify that it complies with the hospital local and national impedance requirements A ground post located on the back of the display may be used for the purpose of grounding the display s chassis Any such ground must be installed in accordance with applicable electrical codes The ground post is shown on the mechanical drawing found on page 2 Recycling Follow local governing ordinances and recycling plans regarding the recycling or disposal of this equipment Declarations of Conformity FCC and Council Directives of European Standards This device complies with Part 15 of FCC rules and 93 42 EEC of the Council Directives of European Standards Operation 15 subject to the following two conditions 1 This device may not cause harmful interference
6. M D S DATA 0 T M D S DATA 4 T M D S DATA 0 5 SHIELD T M D S DATA 4 T M D S DATA 5 DDC CLOCK T M D S DATA 5 DDC DATA T M D S CLOCK SHIELD ANALOG VERT SYNC DVI 2 Only T M D S CLOCK T M D S DATA 1 T M D S CLOCK RGBS amp ANALOG RED T M D S DATA 1 T M D S DATA 1 3 SHIELD T M D S DATA 3 ANALOG GREEN T M D S DATA 3 ANALOG BLUE 5V POWER ANALOG HORIZ SYNC ANALOG GROUND 16 17 18 C1 C2 C3 C4 GND 14 Power Connectors and Pin Out 24 volt connector Shield 5 Volt Connectors SMK P N LLP 0143 5 Volt Connector Wiring Connector Center Pin Shell CUI P N PP 015 5 VDC Return SMK P N LLP 0143 5VDC Return 15 Specifications Viewable Diagonal inches Contrast Ratio typical VGA Input signal level at 75 Ohm HD SDI Input signal level 0 8 to 2 0 V p p S Video Input signal level 0 7 V p p Composite Input signal level 0 7 V p p RGBS Input signal level 0 7 V p p RGBS Input Sync level 0 4 to 4 0 V p p Altitude Notes 1 Specifications are subject to change without notice Contact factory for current specifications 2 Brightness shown is without a Touch Screen or A R filter installed 3 Applies to the SL Power Electronic Corp MW155RA2400F02 power supply provided with the display AC input 100 to 240 Volts at 50 to 60 Hz D
7. contaminates near the sterile field SOURCE DVI HD SDI HD RGBS HD YPbPr RGBS YPbPr SDI S Video Composite VGA APPLICATION e HD Endoscopy PACS Vital Signs Room Camera HD Endoscopy SD Endoscopy Fluoroscopy SD Endoscopy Ultrasound PACS Endoscopy Ultrasound Angiography 18 Safety Precautions Classification Product Disposal Safety Precautions To prevent the risk of electric shock make sure power cord is unplugged from wall socket To fully disengage the power to the unit please disconnect the power cord from the ac outlet Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked Hospital Only or Hospital Grade The signal input parts or signal output parts SIP SOP need to be connected properly and any unused SIP SOP shall not be accessible to unqualified personnel after the LCD is integrated into a medical system Classification Power by Class power Adapter No Applied Part Ingress Protection IPXO Front side can meet IP32 3 opening size minor dim lt 2 5mm 2 dripping water front only 15 from vertical Mode of operation Continuous Operation The equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide Not AP or APG Category Product Disposal e Outside the European Union If you wish to dispose of used electrical and electronic products outside
8. B button to select any of the 19 languages DPMS Enable Display Power Management System When DPMS is enabled on and no input signal is present an Entering Power Save Mode message is displayed for 10 15 seconds after which the display shuts down This prolongs the life of the backlight tubes in the display The display turns on when the input signal 15 restored Press the button to enable DPMS press the button to disable DPMS Auto Source Select on Searches through all possible input sources until an active video source is found off Video input is manually selected Press the lt or button to disable or enable Auto Source Select Menu Lock Disables access to menu system This prevents inadvertent changes to the display s settings To enable Menu Lock press the button MENU LOCKED is displayed when the button is pressed To unlock simultaneously press and hold the MENU and SCROLL buttons until MENU UNLOCKED 15 displayed Operating Hours Backlight hours of operation BIOS Version of the display s BIOS firmware 10 Defaults Menu Factory Defaults Press to select User Defauts EMPTY User Defaults 2 EMPTY User Defaults 3 SSE User Defaults 4 EMPTY User Defaults 5 EMPTY Factory Defaults Displays Restoring Factory Defaults message and returns all settings to their factory preset values Press the SCROLL button to highlight Factory Defaults then press the button User Defau
9. C Power Consumption nominal 3 115W 16 BNG 75 Ohm terminated DIN 4 75 Ohm terminated DVI A 75 Ohm terminated HD 15 75 Ohm terminated BNG 75 Ohm terminated Standard Digital Analog Video Formats Interlaced Progressive SMPTE 259M C ITU 601 SMPTE 259M C ITU 601 1080 60p RGBS YPbPr HD SDI DVI 67 300 SMPTE 274M Cleaning Instructions We recommend turning the display off prior to cleaning Follow your organization s protocol for the handling of blood and body fluids Clean the display with a diluted mixture of mild detergent and water Use a soft towel or swab Use of certain cleaning agents may cause degradation to the plastic enclosure and labels of the product The plastic is ABS Consult the cleanser manufacturer to see if the agent used is compatible with ABS Do not allow liquid to enter the display Applications Supported Devices Fully compliant for medical use in surgery the EndoVue widescreen from NDSsi offers a high quality low cost solution for surgical imaging environments Its compact and lightweight design makes it very maneuverable and easy to install on a surgical cart or boom arm The new EndoVue is an affordable alternative to a full featured surgical display but can still accommodate high definition signals from a variety of medical imaging sources including endoscopes ultrasound PACS and vital signs It also features a fanless cooling design to minimize the risk of spreading airborne
10. Disposal 19 VESA Mounting nn 20 Contaci D DM E E E EEES 22 1 CAUTION This symbol alerts the user that important literature concerning the operation of this unit has been included Therefore it should be read carefully in order to avoid potential problems to cause electrical shock Therefore it is dangerous to make contact with any part inside the unit To reduce the risk of electric shock DO NOT remove cover or back There are no user serviceable parts inside Refer servicing to qualified service personnel To prevent fire or shock hazards do not expose this unit to rain or moisture Also do not use this unit s polarized plug with an extension cord receptacle or other outlets unless the prongs can be fully inserted The display is designed to meet the medical safety requirements for a patient vicinity device This device may not be used in connection with life support equipment h This symbol warns user that un insulated voltage within the unit may have sufficient magnitude BALA Underwriters Laboratories UL Classification U C US UL Safety Compliance 9 This LCD monitor is U L Classified WITH RESPECT TO ELECTRIC SHOCK FIRE AND MECHANICAL sun HAZARDS ONLY IN ACCORDANCE WITH UL 60601 1 CAN CSA C22 2 NO 601 1 EEC Safety Compliance This display unit meets the requirements of EN 60601 1 so as to conform to the Medical
11. NDS SURGICAL IMAGING ENDOVUE 24 SURGICAL DISPLAY High Definition OEndoVue USER MANUAL O 2009 NDS Surgical Imaging LLC rights reserved Information in this document has been carefully checked for accuracy however no guarantee is given to the correctness of the contents This document is subject to change without notice NDSsi provides this information as reference only Reference to products from other vendors does not imply any recommendation or endorsement This document contains proprietary information protected by copyright No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of NDSsi NDS Surgical Imaging NDSsi Radiance and SmartSync are either registered or unregistered trademarks of NDS Surgical Imaging All other trademarks are the property of their respective owners Table of Contents Tab 1 Safety Considerations ii Declaration of Conformity iii Legal Statement iii Tab 2 About This Manual 1 Quick Startup
12. X 20 Notes Notes Notes n p p A Li 1 p El SURGICAL IMAGING WWW NDSSI COM 60G0410 Corporate Headquarters NDS Surgical Imaging 5750 Hellyer Avenue San Jose CA 95138 USA Tel 408 776 0085 Fax 408 776 9878 EMail info ndssi com Europe Headquarters NDS Surgical Imaging BV Nijverheidscentrum 28 2761 JP Zevenhuizen ZH The Netherlands Tel 0031 180 63 43 56 Fax 0031 180 63 21 91 E Mail info ndssi nl Japan Headquarters NDS Surgical Imaging K K Takanawa Kaneo Bldg 6F 3 25 22 Takanawa Minato ku Tokyo 108 0074 Japan Tel 81 3 5475 1835 Fax 81 3 5475 2835 Email info ndssi jp
13. d right 1 1 Displays the video data in its native size and aspect ratio Image may be displayed with black bars on the top and bottom and on the left and right Se lect using lt or buttons Color Menus 18 20 22 24 26 Video PACS Color Temperature SDI S Video Composite YPbPr DVI YPbPr Gamma for graphic mode e g 1920 x 1200 60 0 Hz Press 4 or B to select a preset Gamma Video or PACS Notes 1 Video is a color corrected Look Up Table LUT available with DVI and VGA 2 Picture Archive Communications System PACS 15 DICOM like LUT available with DVI and VGA Saturation for video mode e g 1920 x 1080p 30 0 Hz Press lt gt to set the saturation color intensity of the image Red Green Blue for both graphic video mode Press the lt or B button to increase or decrease the intensity of the selected color Hue for video mode e g 1920 x 1080p 30 0 Hz Press lt or gt to set the hue color tint of the image Setup Menu Menu Position Language English DPMS Enable Off Auto Source Select Off Menu Lock Operating Hours BIOS 58M0001 Version 07 Menu Position Places the menu in 1 of 9 predefined screen positions Press the lt or B button to select any of the 9 screen positions Language Selects 1 of 19 languages English Deutsch Francais Italiano Nederlands Espanol Dutch etc Press the 4 or
14. d shipment non delivery product failure product design or production inability to use such products or services loss of future business lost profits or from any other cause whatsoever in connection with or arising from the purchase sale lease rental installation or use of such NDS products these terms and conditions or with respect to any the terms of any agreement which incorporates these terms and conditions SOME JURISDICTIONS DO NOT ALLOW EXCLUSIONS AND DISCLAIMERS OF CERTAIN WARRANTIES OR LIMITATIONS OF LIABILITY SO THE LIMITATIONS AND OR EXCLUSIONS SET FORTH HEREIN MAY NOT APPLY IN THAT EVENT LIABILITY WILL BE LIMITED TO THE GREATEST EXTENT PERMITTED BY LAW IN THE SUBJECT JURISDICTION The information provided in this document including all designs and related materials is the valuable property of NDS and or its licensors and as appropriate they reserve all patent copyright and other proprietary rights to this document including all design manufacturing reproduction use and sales rights thereto except to the extent said rights are expressly granted to others About This Manual This manual is designed to assist the user with proper installation setup and operation of the EndoVue LCD display Depending on the model and options that were purchased some of the features and options in this manual may not apply to the display you are using A black numbered tab on the side of the page denotes the beginning of a sec
15. ed to the sale and or use of its products To ensure proper use handling and care of NDS products customers should consult the product specific literature instruction manual and or labeling included with the product or otherwise available Customers are cautioned that system configuration software the application customer data and operator control of the system among other factors affect the product s performance While NDS products are considered to be compatible with many systems specific functional implementation by customers may vary Therefore suitability of a product for a specific purpose or application must be determined by the consumer and is not warranted by NDS NDS SPECIFICALLY DISCLAIMS ALL WARRANTIES OF ANY KIND WHETHER EXPRESS IMPLIED AND OR STATUTORY INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY FITNESS AND OR OF SUITABILITY FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT WITH RESPECT TO ALL NDS PRODUCTS OR SERVICES ANY AND ALL OTHER WARRANTIES REPRESENTATIONS AND OR GUARANTEES OF ANY TYPE NATURE OR EXTENT BE IT IMPLIED EXPRESS AND OR WHETHER ARISING UNDER OR AS A RESULT OF ANY STATUTE LAW COMMERCIAL USAGE CUSTOM TRADE OR OTHERWISE ARE HEREBY EXPRESSLY EXCLUDED AND DISCLAIMED NDS its suppliers and or distributors are not liable directly or by way of indemnity for any special incidental consequential punitive exemplary or indirect damages including but not limited to alleged damages for delaye
16. es the incoming signal and automatically displays the video image in its proper format To run SmartSync select the SmartSync Alternate Modes parameter and press the lt button An Alternate Mode may be selected by pressing the button The Alternate Mode format parameter has two arguments X and Y The left X argument is the current mode and the right Y is the number of modes available The mode format and or Frequency changes each time the B button is pressed When the mode count reaches its maximum the next B button press returns the mode count to 1 DVI Digital Picture Menu Overscan Video This parameter is enabled when the input is video camera data The image is displayed at a size that fills the screen without losing any video information The image presented to the display may include black bars top and bottom or left and right 1 2 3 4 5 or 6 The image 15 linearly enlarged while remaining centered in incremental steps As the image becomes larger video information will be lost from the top and bottom and or left and right Se lect using 4 or buttons Scaling Graphics This parameter is enabled when the input is graphics computer data Fill Expands the video image to fill the entire screen The aspect ratio may not be accurately displayed Aspect Expands the video image until its largest dimension fills the screen Image may be displayed with black bars on the top and bottom or the left an
17. ll look crisper than those of a traditional CRT For the same reason live video may appear a little blocky Users not familiar with the image differences should familiarize themselves before utilization in a critical application and determine its usability It is recommended that first time users view the display next to a CRT to familiarize themselves with any subtle differences in viewing quality Connector Panels oa N Notes 1 DCIN power supply cord shall be reliably fixed and not be removable without the use of a TOOL 2 The 5V 1A DC output is protected Auxiliary connection See page 15 for details Electrical Symbols Y Equipotentiality connector to other equipment earth equipotential This symbol appears next to the display s Potential Equalization Conductor ground post Open Off Switch This symbol appears on the open or off side of the display s rocker switch Alternating Current Closed On Switch This symbol appears on the closed or on side of the display s rocker switch Direct Current Control The display is controlled via a 6 button keypad The keypad located on the bottom front of the display allows the user to make adjustments to various display parameters using the On Screen Menus OSM system INPUT SCROLI Image Adjustments Adjust Brightness Press the Brightness Contrast button to display the Brightness control Press the
18. lower refresh rates 60 Hz 15 optimal and data update will be the same at all refresh rates Text is Too Small Since the monitor accepts and displays computer data with a higher resolution than the display s native resolution this may produce small text In the Menu check the Display Mode tab Verify that the computer data resolution does not exceed the Native Resolution specification shown on page 16 Character Jitter If text characters seem to be shaky or bold then Sharpness Frequency and or Phase may require adjusting See Setting Frequency Phase and Sharpness below Character Noise and Vertical Distortion The Frequency adjustment expands or contracts the horizontal size of the displayed image The displayed image may be too wide or too narrow and vertical banding and pixel jitter may appear in grays and light colors Adjust the Frequency until the image just fits the screen Horizontal position adjustment can be used to verify that Frequency is set correctly Line up the image on the left edge of the screen and then shift by one click to the right The image should have one column off the screen on the right side if the Frequency 15 set correctly Black Screen Power the display Off and On If the NDS logo appears then the display is working properly Check if the power management feature DPMS is enabled A Searching message appears when the video source is not present or when an input source is out of the display
19. lternate Modes DIU Press Menu Position 5 Es Factory Defaults Press to select Language English User Defaults 1 EMPTY BEN EIGEN ol User Defauts 2 ET Auo Source Select on taa Seen Menu User Defauks 4 Operating Hours User Defaults 5 BIOS 58M0001 Version A07 Dama ems Video Source Inputs Menu RGBS YPbPr S Video DYI Composite When the display is powered on Auto Source Select looks at the previously selected video source first signal is present it is displayed otherwise Auto Source Select starts scanning the inputs for a signal To switch to a different input source press the INPUT button to open the input menu The Input menu shows selected to the right of the active input Press the SCROLL button to highlight the desired input Finally press the 4 button to select it Setting Up the Display SDI Picture Menu Horizontal Position Vertival Position Sharpness O Video Format S Video Picture Menu Horizontal Position Vertical Position Sharpness Overscan Video Format Composite Picture Menu Horizontal Position Vertical Position Video Format Horizontal Position Moves the image to the left or right Press or to horizontally center the image Vertical Position Moves the image up or down Press lt or to vertically center the image Sharpness Press 4 or B to adjust the sharpness focus of the di
20. lts Allows up to five customized user settings to be saved Setting User Defaults 1 2 3 4 5 Set the Picture Color and Setup parameters to the user s preferences Select the Defaults tab Use the SCROLL button to select an available User Defaults EMPTY appears in available User Defaults Press the lt to save the user s settings The EMPTY message will be removed see User Defaults 1 in the above OSM illustration Repeat steps 1 thru 4 for up to 5 users Restoring User Defaults 1 Select the User Defaults to be restored then press the button Clearing User Defaults 1 Select the User Defaults to be cleared then press the Brightness Contrast button Note The prompt at the bottom of the Defaults menu appears only when one of the User Defaults 15 selected 11 Troubleshooting Section Image Size is Very Large for the Screen If the computer data does not appear to be the correct format then SmartSync must be run To run SmartSync press the Menu button Select the Setup menu Press SCROLL to highlight SmartSync then press the 4 button SmartSync will run and size the image properly Ghosting in Characters Ghosting in characters is usually attributed to reflections in the video cable or source Use a high quality coaxial cable and if possible lower the vertical refresh rate Lower scan rates can help eliminate reflections Unlike a CRT a flat panel will not flicker at
21. ng at native resolution Phase Press lt or B to adjust the phase of the display s pixel clock Frequency Adjusts the frequency of the display s pixel clock With Scaling set to Fill adjust until image just fills the screen horizontally Press or B to adjust the frequency of the display s pixel clock Overscan Video This parameter is enabled when the input is video camera data The image is displayed at a size that fills the screen without losing any video information The image presented to the display may include black bars top and bottom or left and right 1 2 3 4 5 or 6 The image 15 linearly enlarged while remaining centered in incremental steps As the image becomes larger video information will be lost from the top and bottom and or left and right Select using lt or B buttons Scaling Graphics This parameter is enabled when the input is graphics computer data Fill Expands the video image to fill the entire screen The aspect ratio may not be accurately displayed Aspect Expands the video image until its largest dimension fills the screen Image may be displayed with black bars on the top and bottom or the left and right 1 1 Displays the video data in its native size and aspect ratio Image may be displayed with black bars on the top and bottom and on the left and right Select using lt or B buttons SmartSync Alternate Modes On initialization NDS proprietary SmartSync technology examin
22. r relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult your dealer or an experienced radio TV technician for help Accessory equipment connected to this monitor must be certified according to the respective IEC Standards i e IEC 60950 1 for data processing equipment and IEC 60601 1 for medical equipment Furthermore all configurations shall comply with the system standard IEC 60601 1 1 Anyone who connects additional equipment to the signal input part or signal output part configures a medical system and is therefore responsible that the system complies with the requirements of system standard IEC 60601 1 1 Whoever is responsible for securing the monitor to a system needs to insure that the mounting equipment used with this display complies to IEC standard 60601 1 If in doubt consult the technical services department or your local representative Legal Statement NDS sells its products through other medical device manufacturers distributors and resellers and therefore purchasers of this NDS product should consult with the entity through which this product was originally purchased regarding the terms of any applicable product warranties provided by such entity if any NDS neither assumes nor authorizes any person to assume for it any other liabilities in conjunction with and or relat
23. re Menu 8 Color Menus 9 Setup Menu xp 10 Defaults Menu 11 Tab 6 Troubleshooting 12 Tab 7 Drawing and Dimensions 13 Tab 8 Data Connectors and Pin Outs 14 Power Connector and Pin Out 15 Tab 9 Specifications 16 Video Inputs nnn nnn nnn nnn nnn senna 17 Video Formats 17 Cleaning Instructions 17 Applications Supported Devices 18 Safety Precautions 19 Classification 19 Product
24. splayed image Overscan Video This parameter is enabled when the input is video camera data The image is displayed at a size that fills the screen without losing any video information The image presented to the display may include black bars top and bottom or left and right 1 2 3 4 5 or 6 The image 15 linearly enlarged while remaining centered in incremental steps As the image becomes larger video information will be lost from the top and bottom and or left and right Select using lt or B buttons Video Format Auto Automatically sets the unit to the format of the connected video source NTSC Sets the unit to accept NTSC video PAL Sets the unit to accept PAL video Select using lt or B buttons VGA RGBS Picture Menu Horizontal Position Vertical Position Sharpness Phase Frequency Scaling rn Aspect 13 SmartSync Press Alternate Modes oro Press El YPbPr Picture Menu Horizontal Position Vertical Position Sharpness Phase Frequency Overscan Aspect SmartSync Press 2 Alternate Modes 0 0 Press Horizontal Position Moves the image to the left or right Press or to horizontally center the image Vertical Position Moves the image up or down Press lt to vertically center the image Sharpness Press lt or B to adjust the sharpness focus of the displayed image Note When the VGA input is active Sharpness cannot be adjusted when the display is operati
25. the European Union please contact your local authority so as to comply with the correct disposal method e Within the European Union EU wide legislation as implemented in each Member State requires that waste electrical and electronic products carrying the mark left must be disposed of separately from normal household waste This includes monitors and electrical accessories such as signal cables or power cords When you need to dispose of your display products please follow the guidance of your local authority or ask the shop where you purchased the product The mark on electrical and electronic products only applies to the current European Union Member States VESA Mounting Install VESA Mounting The LCD display provides standard VESA 100mm mounting allowing the display to be conveniently integrated a system Installation should be performed by a qualified technician Please contact your provider s service department if you require assistance installing the display VESA mounting dimension diagram 100 x 100 mm Installation instructions follow The wall mounting attachment is comprised of one mounting bracket and screws Attach the mounting bracket to the rear cover of the LCD display using the provided M4 type screws The mounting bracket must be securely tightened Failure to properly secure the display to the mounting bracket could be hazardous Monitor Mounting Detail X 0 7 thread 10mm deep 10
26. tion The functional descriptions in this manual are representative of Part Numbers 90K0001 Except U S A and Canada and 90K0004 U S A and Canada only Firmware BIOS 58M0001 0 Version and later Note This BIOS supports both High Definition SDI HD SDI and Standard Definition SDI SD SDI Manual Part Number 60G0410 Rev C Intended Use and Contraindications Intended Use This monitor is intended for use in a medical environment to display high quality video and graphic images Contraindications The monitor may not be used in the presence of flammable anesthetics mixture with air oxygen or nitrous oxide For mission critical applications we strongly recommend that a replacement unit be immediately available Quick Startup Powering On The Unit Connect the power supply to the display via the power plug Plug in the AC adapter Connect a video source to the display Apply power to the peripheral device then to the display The power switch location is Shown on page 13 The NDS logo is displayed followed shortly by video The electronics designed by NDS incorporates proprietary SmartSync technology which at initialization examines the incoming signal and automatically displays the video image in its proper format This eliminates adjustments for most video sources To fine tune the image please refer to Image Adjustments on page 3 First time users and initial test Visually Flat Panel LCD images wi

Download Pdf Manuals

image

Related Search

Related Contents

ANXS-LUMI説明書  Capi2 brochure  NEC V463-AVT Mechanical Drawings  ABUS TV7181 surveillance camera  ファームエイジ株式会社 基本アースセット取扱説明書  Tripp Lite 50-ft. HDMI Gold Digital Video Cable HDMI-M / HDMI-M  Weather Wizard User Manual  Stampante multifunzione in bianco e nero Xerox® WorkCentre® 3615  User`s Manual LGP Series Handheld CCD Scanner 25  Rutland 914i Windcharger Owners Manual  