        traceable® jumbo refrigerator/freezer thermometer instructions
         Contents
1.       To change between ambient  IN  and probe  OUT  temperature display modes  press  the IN OUT button located on the back of the unit     To change between displaying the memory  MIN MAX  and the alarm limits  HI LO    press the MODE button     DISPLAYING   F OR   C  To display the temperature readings in Fahrenheit or Celsius  press the   C   F button  located on the back of the unit     MINIMUM AND MAXIMUM MEMORY   There are four points that are automatically recorded into memory   Minimum  MIN  Ambient Temperature Achieved   Maximum  MAX  Ambient Temperature Achieved   Minimum  MIN  Probe Temperature Achieved   Maximum  MAX  Probe Temperature Achieved    All four memories are independent of each other  Minimum and maximum  temperature memories are NOT programmable  The minimum temperature recorded  into memory is the minimum temperature achieved since the last time the memory was  cleared  The maximum temperature recorded into memory is the maximum  temperature achieved since the last time the memory was cleared  The minimum and  maximum temperature memories are maintained over the period since the memory  was cleared     Minimum and maximum memories are recorded for both ambient and probe  temperatures regardless of the display mode     CLEARING THE PROBE  OUT  TEMPERATURE MEMORY   1  Select the Probe Temperature Display Mode by pressing the IN OUT button located  on the back of the unit until    OUT    appears on the display    2  Press the MODE button until    MIN   
2.    2  Once the above items have been manually recorded  clear both the minimum and  maximum temperature memory   See the    Clearing the Probe  OUT  Temperature  Memory    section      By clearing the memory each day  the minimum and maximum temperature memory will  provide a record of the minimum and maximum temperature that has been achieved  inside the refrigerator over the past 24 hour monitoring period  The memory will also  allow the user to see if the temperature inside the refrigerator went outside of the  acceptable range when there was no one available to hear the alarm  overnight      ALL OPERATIONAL DIFFICULTIES   If this unit does not function properly for any reason  replace the battery with a new  high quality battery  see the    Battery Replacement    section   Low battery power can  occasionally cause any number of    apparent    operational difficulties  Replacing the  battery with a new fresh battery will solve most difficulties     BATTERY REPLACEMENT   Erratic readings  a faint display  no display  or a battery symbol appearing on the  display are all indications that the battery must be replaced  Open the battery  compartment by depressing the tab located at the top of the battery cover and lifting it  out  The battery cover is hinged at the bottom so that the battery compartment may be  opened without completely removing the battery cover  Remove the exhausted  battery and replace with a AAA alkaline battery  Make certain to insert the new battery  with
3.   Set a screw into the wall at the desired location  Do not set the screw flush to the wall   the head of the screw will need to slip into the receptacle on the back of the unit  Once  the screw has been properly set  hang the unit in place by sliding the receptacle on the  back of the unit over the head of the screw     USING THE ALARM AND MEMORY TO MONITOR A REFRIGERATOR FREEZER    Following is an example of how to use the alarm and memory to monitor the  temperature inside a refrigerator or freezer  This example is provided only as a helpful  guide and is not intended to replace existing facility requirements or procedures     In this example  the refrigerator temperature must be monitored and logged for each  24 hour period and certain actions must be taken if temperature falls below 0  C or  rises above 5  C at any time during the 24 hour period     Unit Setup Example    Plug the probe into the unit   Install the battery   Place the probe sensor inside the refrigerator   Place the display outside the refrigerator   Select the Probe Temperature Display mode   See the    Temperature Display  Modes    section      OV EO Ne    At this point  if using a bottle probe  allow sufficient time for the bottle probe to reach  equilibrium with the true current temperature inside the refrigerator     6  Set the probe temperature low alarm limit to 0  C   See the    Setting Probe  OUT   Temperature Alarm Limits    section     7  Set the probe temperature high alarm limit to 5  C   See 
4.  and    MAX    appears on the display    3  Press the MIN RESET button to clear the minimum temperature memory  The  display will show    88 8    under MIN and will then display the new minimum  temperature memory    4  Press the MAX RESET button to clear the maximum temperature memory  The  display will show    88 8    under MAX and will then display the new maximum  temperature memory     CLEARING THE AMBIENT  IN  TEMPERATURE MEMORY   1  Select the Ambient Temperature Display Mode by pressing the IN OUT button  located on the back of the unit until    IN    appears on the display    2  Press the MODE button until    MIN    and    MAX    appears on the display    3  Press the MIN RESET button to clear the minimum temperature memory  The  display will show    88 8    under MIN and will then display the new minimum  temperature memory    4  Press the MAX RESET button to clear the maximum temperature memory  The  display will show    88 8    under MAX and will then display the new maximum  temperature memory     ALARMS  Both ambient  IN  and probe  OUT  temperature alarm limits may be set in 1    increments     With the alarm enabled    A   the unit will sound an alarm when the temperature being  displayed is outside the alarm limits that have been set for that display mode  equal to  or lower than the low alarm set point  or equal to or greater than the high alarm set  point   Example  If the unit is displaying the ambient temperature  IN  and the probe  temperature  OUT  is o
5.  the proper polarity as indicated in the illustration in the battery compartment   Close the battery cover     Replacing the battery has the same affect as pressing the RESET button   See the     RESET BUTTON    section      Warranty  Service  or Recalibration  For warranty  service  or recalibration  contact     CONTROL COMPANY  4455 Rex Road  Friendswood  Texas 7 546 USA  Ph  281 482 1714  Fax 281 482 9448  E mail sales control3 com  www control3 com    Control Company is ISO 9001 Quality Certified by  DNV and ISO 17025 accredited as a Calibration  Laboratory by A2LA     Control Company Cat  No  92 4148 00  Traceable   is a registered trademark of     Control Company     2008    Control Company    
6. TRACEABLE   JUMBO REFRIGERATOR FREEZER THERMOMETER INSTRUCTIONS    SPECIFICATIONS   Range   58 0 to 158 0   F    50 0 to 70 0   C  Resolution  0 1     Update Rate  10 seconds   Battery  AAA  1 5V     Probe Supplied    Model 4148   Supplied with a standard probe sensor with cable  Both sensor and  cable may be immersed in liquid  Probe sensor may be mounted using the supplied  sensor holder and mounting screw    Model 4548  amp  4648   Supplied with a bottle sensor and cable  Bottle sensor is filled  with a patented nontoxic glycol solution that is GRAS  Generally Recognized As Safe   by the FDA  Food and Drug Administration  eliminating concerns about incidental  contact with food or drinking water  The solution filled bottle simulates the temperature  of other stored liquids  Velcro   and a magnetic strip are provided to mount the bottle  to the inside of a refrigerator freezer and to mount the display on the outside  The  micro thin probe cable permits refrigerator freezer doors to close on it     TEMPERATURE DISPLAY MODES   Ambient Temperature Display Mode  IN   Indicated by    IN    appearing on the  display  displays the current ambient temperature and either the ambient temperature  memory  MIN MAX  or the ambient temperature alarm limits  LO HI     Probe Temperature Display Mode  OUT     Indicated by    OUT    appearing on the display  displays the current probe temperature  and either the probe temperature memory  MIN MAX  or the probe temperature alarm  limits  LO HI
7. he probe temperature   OUT  is outside the probe temperature alarm limits  no alarm will sound     RESET BUTTON  The RESET button located on the back of the unit may be used to simultaneously  reset the memory and alarm limits for both the ambient  IN  and probe  OUT  sensor     To reset the unit  press the RESET button     When the reset button in pressed  the following will occur     The display will show all segments for approximately 5 seconds     The ambient  IN  and probe  OUT  minimum maximum memory will be cleared       The ambient  IN  and probe  OUT  alarm limits will be returned to the factory  default value of 10  C  LO  and 30  C  HI        The unit will display the ambient  IN  temperature in   C     ON OFF BUTTON   The ON OFF button located on the back of the unit may be used to turn the unit off  when the thermometer is not being used  The minimum maximum memory and  alarm limits are not cleared when the unit is turned off  To turn the unit off  press the  ON OFF button  Each successive press of the ON OFF button will turn the unit on or  off     No alarms will sound and no minimum maximum memory will be recorded when  the unit is off     BENCH STAND   The unit is supplied with a bench stand that is a part of the back of the unit  To use  the bench stand  locate the small openings on either side of the bottom of the unit   Place your fingernail into one of the openings and flip the stand out  To close the  stand  simply snap it shut     WALL MOUNTING THE UNIT 
8. le the alarm to sound when the temperature being displayed is outside the  alarm limits  press the    button located on the back of the unit until    A    appears on  the display  Each successive press of the A button will enable      or disable the  alarm     ALARM SOUNDING   With the alarm enabled  4A   the unit will sound an alarm when the temperature being  displayed is outside the alarm limits that have been set for that display mode  equal to  or lower than the low alarm set point  or equal to or greater than the high alarm set  point   If the alarm is sounding based on the low alarm limit     LO    will flash on the  display  If the alarm is sounding based on the high alarm limit     HI    will flash on the  d    isplay     2   3    The unit will continue to alarm and flash the corresponding    LO    or    HI    until the  temperature being displayed is within the alarm limits  Once the temperature being  displayed is within the alarm limits  the alarm will stop sounding and the  corresponding    LO    or    HI    will no longer flash           To silence an alarm manually  press any button  When manually silenced  the  corresponding    LO    or    HI    will continue to flash on the display until the temperature is  within the alarm limits     When enabled  A   the alarm will only sound if the temperature being displayed is  outside the alarm limits that have been set for that display mode  IN or OUT    Example  If the unit is displaying ambient temperature  IN  and t
9. the    Setting Probe  OUT   Temperature Alarm Limits    section     8  Enable the alarms   See the    Enable Disable Alarms    section     9  Clear the minimum and maximum memory   See the    Clearing the Probe  OUT   Temperature Memory    section     10  Select the probe temperature with Min Max memory display mode   See the     Temperature Display Modes    section      The alarm limits have been set and the alarm has been enabled  The display has been  set to show the current temperature inside the refrigerator along with the minimum and  maximum temperature that has been achieved inside the refrigerator     If the temperature inside the refrigerator goes outside the alarm limits  equal to or  lower than the low alarm set point  or equal to or greater than the high alarm set point    the alarm will sound     If no one is available to hear the alarm sounding  overnight   and the temperature  returns to an in range condition  the memory will provide a record of the single lowest  and highest temperature achieved  When the temperatures are recorded into the  manual log  the memory will allow the user to see that the temperature inside the  refrigerator had gone outside of the acceptable range     Monitoring Procedure Example  Keep a notebook or spreadsheet as a manual log     1  Atthe same time every day  record the following into the manual log     Current Date and Time    Current Temperature Reading     Minimum Temperature Reading  MIN      Maximum Temperature Reading  MAX  
10. utside the probe temperature alarm limits  no alarm will sound     SETTING PROBE  OUT  TEMPERATURE ALARM LIMITS   1  Select the Probe Temperature Display Mode by pressing the IN OUT button  located on the back of the unit until    OUT    appears on the display    2  Press MODE button until    LO    and    HI    appears    3  To set the low temperature alarm limit  LO   press the LO ALM SET button to  advance the display until the desired low temperature is displayed  Press and hold  the LO ALM SET button to rapidly advance the display    4  To set the high temperature alarm limit  HI   press the HI ALM SET button to  advance the display until the desired high temperature is displayed  Press and hold  the HI ALM SET button to rapidly advance the display     SETTING AMBIENT  IN  TEMPERATURE ALARM LIMITS   1  Select the Ambient Temperature Display Mode by pressing the IN OUT button  located on the back of the unit until    IN    appears on the display    2  Press MODE button until    LO    and    HI    appears    3  To set the low temperature alarm limit  LO   press the LO ALM SET button to  advance the display until the desired low temperature is displayed  Press and hold  the LO ALM SET button to rapidly advance the display    4  To set the high temperature alarm limit  HI   press the HI ALM SET button to  advance the display until the desired high temperature is displayed  Press and  hold the HI ALM SET button to rapidly advance the display     ENABLE DISABLE ALARMS   To enab
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
N°4 - Le Canard en Chainon  パットウォール取扱説明書  TDSHーBA 保管用  Philips Soft-shell case DLM6304  Mounting and Operating Instructions EB 8330 EN  Honda Power Equipment BF130A Boat User Manual  LDRCheck-D  Explorer® séries 8000 et 8300, ENP et ENP HD - Affaires  Manuel d``utilisation  Hannspree ST19KMAW 19" HD-Ready Red LCD TV    Copyright © All rights reserved. 