1. Figure 13 Cognitiv training of push with animate cube according to training action selected Finally you are prompted to accept or reject the training recording Ideal Cognitiv detection performance is typically achieved by supplying consistent training data i e a consistent mental visualization on the part of the user across several training sessions for each enabled action The ability to reject the last training recording allows you to decide whether you were able to remain mentally focused on the appropriate action during the last training session Alternatively you may press the Abort Training button to abort the training recording if you are interrupted become distracted or notice problems with the EPOC Neuroheadset contact quality indicators during the recording A training session is automatically discarded if the wireless signal strength or EEG signal quality is poor for a significant portion of the training period A notification will be displayed to the user if this has occurred 3 3 4 Training Neutral The Neutral action refers to the user s passive mental state one that isn t associated with any of the selected Cognitiv actions While training Neutral you should enter a mental state that doesn t involve the other Cognitiv actions Typically this means engaging in passive mental activities such as reading or just relaxing However to minimize false positive Cognitiv action results i e incorrect reporting
2. The Affectiv Suite panel contains two graph panes displaying the three Affectiv detections instantaneous and long term average time scales The top chart is configured to plot 30 seconds of data for the Engagement Meditation and Instantaneous Excitement detections The bottom chart defaults to display 5 minutes worth of data for the Long Term Engagement Meditation and Excitement detections The values that are plotted on the graphs are the output scores returned by the Affectiv detections 3 2 3 Affectiv Suite Detection Details Scoring behavior In general the greater the increase in physiological arousal the greater the output score for the detection Instantaneous Excitement is experienced as an awareness or feeling of physiological arousal with a positive value Excitement is characterized by activation in the sympathetic nervous system which results in a range of physiological responses including pupil dilation eye widening sweat gland stimulation heart rate and muscle tension increases blood diversion and digestive inhibition The Instantaneous Excitement detection is tuned to provide output scores that more accurately reflect short term changes in excitement over time periods as short as several seconds Related emotions titillation nervousness agitation Long Term Excitement is experienced and defined in the same way as Instantaneous Excitement but the detection is designed and tuned to be more accurate when measuring changes i
3. 25 EMOTIV 3 1 Expressiv Suite The Expressive Suite details the facial expressions and non verbal communication capabilities of the EPOC Neuroheadset No longer do you need to push a button or type in emoticons into a chat dialog box during game play Now if you want to show facial expressions on your avatar you need only perform them while wearing the EPOC neuroheadset and you can display these expressions on the face of your avatar P EPOC Control Panel Application Tool USER STATUS Emotiv Engine is ready Headset User 138 854 8 sl G epoc control panel Zo SR ba Ms ks ADD USER REMOVE user save user e look left right E blink ev left wink right wink Tee Figure 5 Expressiv Suite 3 1 1 Understanding the Expressiv Suite Panel Display On the left hand side of the Expressiv Suite panel is a simple avatar The avatar will mimic your facial expressions in camera view i e not mirrored The facial expressions which are displayed include horizontal eye movements to the left and right normal eye blinks left and right sided winks clenching the teeth and smiling On the right hand side of the panel is the Sensitivity panel This panel is explained further in the following section EMOTIV EPOC USER MANUAL 26 EMOTIV 3 1 2 Sensitivity Adjustment Panel The Control Panel offers sensitivity adjustments for the Expressiv Suite detections This is controlled t
4. 3 4 1 Understanding the Mouse Emulator Tab The Mouse Emulator Tab in the EPOC Control Panel allows you to activate the neuroheadset s gyroscope and link it to the control of your computer s mouse cursor The left side of the Mouse Emulator Tab provides a visual representation of the gyroscope s relative position The right side of the Mouse Emulator Tab provides the controls to activate and deactivate this feature along with a slider bar to make sensitivity adjustments EMOTIV EPOC USER MANUAL 39 EMOTIV LA EPOC Control Panel Application Tool Connect Help STATUS USER STATUS System Status Emotiv Engine is ready Headset User 579 286 e froue epoc control panel 29 i Good ecco ADD user Remove user SAvE user PRESS CTRL SHIFT M TO DEACTIVATE Figure 16 Mouse Emulator Tab 3 4 2 Mouse Emulator Controls To enable this feature click on the Activate button Your mouse will immediately respond based on the movement of your head Simply turn your head from left to right up and down You will also notice the orange indicator dot move in accordance with the movement of your head gyroscope The Mouse Sensitivity slider allows you to adjust the sensitivity of the gyroscope when controlling your mouse cursor The Reset button allows you to re centre your position To deactivate this feature use your head movement to move your cursor to the Deactivate button and left mouse click or
5. ADD USER Remove user SAVE user KeySimulationConfigureDialog Send specific keystroke s Hold the key Send hot keys ei att E shift CT win Key hold time 20 ms Key trigger delay time 20 ms Trigger type Limit is equal to Figure 14 EmoKey Configuration Dialogue box Once EmoKey is activated the keystroke s allocated to the Cognitiv action will be marked in the corresponding box An orange highlight will flash in the box to the right of the description of the action being triggered Only actions that have keystrokes allocated will be sent to an application window that is active This is shown in Figure 14 where a pull triggers the keystroke Z Make sure you set the condition to is greater than and enter 0 2 into the condition box at the lower right to trigger the Z key whenever the action strength exceeds 20 of full scale EMOTIV EPOC USER MANUAL 38 EMOTIV LC EPOC Control Panel J Emotiv Engine is ready User SH DIE epoc control panel Z a z s ADD USER J REMOVE user save user Headset Setup Expressiv Suite Affectiv Suite Cognitiv Suite Mouse Emulator Figure 15 EmoKey in Action Linking Pull to keying in Z 3 4 Mouse Emulator The EPOC neuroheadset comes with a built in 2 axis gyroscope which enables a range of additional functions One possible use is mouse cursor control
6. ENGINE STATUS USER STATUS System Status Emotiv Engine is ready Headset User System Up Time 326 515 fo Emotiv User z por control panel XZ Wireless Signal Good Batery Power High ecee ADD USER REMOVE user SAVE user Expressiv Suite Affectiv Suite cognitiv Suite Mouse Emulator Status OK ZN e Headset Setup Guide Step 1 Before putting on the Emotiv headset ensure that each of the 16 electrode recesses are fitted E with a moist felt pad If the pads are not already moist wet them with saline solution before inserting into the headset or alternatively use a medicine dropper to carefully moisten the pads while already in place Step 2 Switch on the Emotiv headset and verify that the built in battery is charged and is providing power by looking for the blue LED located near the power switch at the back of the headset If the headset battery needs charging then set the power switch to the off position and plug the headset into the Emotiv battery charger using the mini USB cable provided with the headset Allow the headset battery to charge for at least 15 minutes before trying again Step 3 Verify that the Wireless Signal reception is reported as Good by looking at the Engine Status box in the Emotiv Control Panel If it is not make sure that the Emotiv Dongle is inserted into a USB port on your computer and that the single LED on the top half of the dongle is on continuously or fl
7. User Manual Headset and software setup for your Emotiv EPOC neuroheadset EMOTIV Table of Contents Quick Start QUIN EEN A Introduction to Emotiv EPOC Neuro technology Neuroheadset 11 NEUROHEADSET FEATURES h Eeer EEN eSa daa ai aaia daa a ara aaa ee iaid 11 APE EE 12 REGULATORY REQUIREMENTS Aaen ee ees EA ele dee a 13 10 Getting Started esl E 15 2 0 Minimum Hardware and Software requirements sssssesseesseesseesreeereerrrerttertrerrereeene 16 2 1 Charging the EPOC Neuroheadset Battery eect eeeeeeeeeeeeeeeeeeteeeaaeeeeeeeeeeeea 16 2 2 Use of Saline Hydration Sensor Pack and Felt Inserts 17 2 3 USB Transceiver Installation ccccceec cece ce eeeeeeeeeeeeeceeceeececeeeeeeeeeseeeseeeeeseeeeeeesneeees 19 2 4 EPOC Control Panel ere E geed EENEG ee 19 2 5 Placement of Emotiv EPOC Neuroheadset on the Head 20 2 6 EMOENGING Status PANS EEN 20 Tel KEE EN 2 EE EE 21 2 8 Sensor Contact Quality Display isi tor eae AcarrnaieesTeaedines tes ei lids ed cravat daniel 22 2 9 Neuroheadset Get Up 23 3 0 Achieving Good Signal Quallity cccccceeeeeseeccceeeeeeeeeseeeeeeeneeeeeeeseesnneeeeeeeeeeneeeeaeees 24 EMOTIV EPOC USER MANUAL EMOTIV 3Al EXPreSSiv t 26 3 1 1 UNDERSTANDING THE EXPRESSIV SUITE PANEL Dispt An 26 3 1 2 SENSITIVITY ADJUSTMENT PANEL sssssnsnnseeeesetstetettst netat tettere te taet rt tateen te renner ne tarere nenen 27 SESA EVS A EE 28 3 2 Ee EL EE 30 3 2 1 AFFECTIV
8. EMOTIV EPOC USER MANUAL 32 EMOTIV S EPOC Control Panell Emokey Help ENGINE STATUS System Status Emotiv Engine is ready d System Up Time 2541 89 Emot user epoc control panel Sa Wireless Signal Good eece Batery Power Hgh eese Lapo user genove user isave user Headset setup Fenn erer tee Figure 10 Cognitiv Suite Panel 3 3 2 Understanding the Cognitiv Panel Display The Cognitiv Suite panel uses a virtual 3D cube to display an animated representation of the Cognitiv detection output This 3D cube is also used to assist the user in visualizing the intended action during the training process The Power gauge to the left of the 3D display is an indicator of the action power or relative certainty that the user is consciously visualizing the current action This information to the right displays the current state of the Cognitiv detection and allows the user to define the current set of actions In order to enable the Cognitiv detection each chosen action plus the Neutral action must first be trained For more information about the training process please refer to Section 3 3 3 below A green checkmark is used to indicate that the corresponding action has been trained an orange X indicates a lack of training data Remember in order for the Cognitiv detection to be activated all actions plus Neutral the user s background mental state must be trained Use the drop down selection menu
9. SUITE INTRODUCTION Feriti a iiae a ae iea atea Dadasi 30 3 2 2 UNDERSTANDING THE AFFECTIV PANEL DISPLAY 1 cecceeceeeeeeeeeeeceaeeaeeeaeeceeeaeesseeeeeeaeeneeeaeeeaes 31 3 2 3 AFFECTIV SUITE DETECTION DETAILS 31 KSC a A SS ILS mee ate Satie tek ete Aus death i aaa ieaie i dea tay e etetea 32 3 3 1 COGNITIV SUITE INTRODUCTION nsssssssense tetet tset tet trett tt attert te tetet Att At Entente EEE er areae Enrere 32 3 3 2 UNDERSTANDING THE COGNITIV PANEL Dispt An 33 3 3 3 COGNIMIV TRAINING eege EE a aE Buc hatenae 34 3 3 4 TRAINING NEUTRAL ccescesceeseeseeeseeseeesecaaeseeceaesaesuaesseecaaesaecaaesaesaaesaeseaesaaesaeesaesaeesaesaresaeeaees 36 3 3 5 CLEAR TRAINING Buro 37 3 SO COGNIMIV IEN esc a deretnca hae aa a aa a a aa aaae e 37 3 3 7 EMOKEY FOR COGNITIV ACTIONS ccceccceccesceeeceseeeeeeaceeeeceeeceeeaaeeaecaecaeeeaesaeeeaeessesieesaeeeeeeaeeeees 37 K NT e E 39 3 4 1 UNDERSTANDING THE MOUSE EMULATOR Tap tter rtattnrrnee renn 39 3 4 2 MOUSE EMULATOR CONTROLS serrare eneee asenna deedee a irer aaeeea area ea aaien at 40 4 0 Trouble Shooting and Help EEN 41 EMOTIV EPOC USER MANUAL EMOTIV Quick Start Guide Items in the EPOC Headset Kit Make sure all items are present in your kit before starting e Headset Assembly with Rechargeable Lithium battery already installed e USB Transceiver Dongle e Hydration Sensor Pack with 16 Sensor Units e Saline solution e 50 60Hz 100 250 VAC Battery Charger US cust
10. and the Emotiv wireless USB receiver connected to your machine If you have not yet connected the display will show No Signal If the wireless signal strength drops too low displayed as Bad or No Signal then no detection results will be transmitted and the Control Panel will disable its detection suite UI controls Battery Power Displays an approximation of the remaining charge in an EPOC Neuroheadset s built in battery 2 7 User Status Use the controls in this section to manage user profiles and assign a specific user via their profile to a specific attached EPOC Neuroheadset Although the EmoEngine supports up to two simultaneously connected EPOC Neuroheadsets EPOC Control Panel only displays status information and detection results for a single EPOC Neuroheadset at a time The Headset combo box allows you to specify the EPOC Neuroheadset that has the current focus In Figure 3 the User Status controls tell us that the Control Panel is currently displaying information for the user with profile Emotiv User wearing EPOC Neuroheadset 0 If you wish to use multiple headsets you can switch between them using the Headset drop down box or you can launch a second instance of EPOC Control Panel and select a different headset for each instance Note neuroheadset numbering begins with 0 and not 1 as you might expect Other operations that are supported include adding saving removing and switching betwe
11. or disconnect other wireless and Bluetooth devices in the area to isolate possible causes EMOTIV EPOC USER MANUAL 41 EMOTIV Weak wireless connection or repeated drop outs expected range 3 5 metres within line of sight e Move closer to the Transceiver Dongle e Obtain a USB male USB female extension cable and plug into the PC Attach the Transceiver Dongle to the extension cable and position in a prominent location away from your PC monitor wireless router and other sources of radio frequency interference e Turn off or disconnect other wireless and Bluetooth devices in the area to isolate possible causes e Turn off neuroheadset unplug Transceiver Dongle and repeat the pairing exercise Sensors do not positively lock in place sensors should click in place as they are rotated a quarter turn clockwise after insertion into the socket e Sensors are made deliberately tight to start with and the locking tabs are slightly deformed to the correct shape during the first fitting Soetimes the sensors are very tight and the user feels they will not turn further into the socket e Take each sensor in turn and use an empty socket in the Hydrator Pack Forcibly rotate the sensor fully clockwise in the socket until a definite click is felt use a cloth or tool to hold the sensor if your fingers are easily damaged Click and unclick the sensor into the socket a few times to complete the process e The sensor can now be fitted to the headset M
12. position press and hold the 2 reference sensors located just above and behind your ears for about 5 10 seconds Good contact of reference sensors is the key for a good signal Check that the lights corresponding to these 2 reference sensors turn from red to green in the EPOC Control Panel Headset Setup screen EMOTIV EPOC USER MANUAL EMOTIV Gently press and hold each remaining sensor against your scalp until all the lights corresponding to those sensors turn to green in the EPOC Control Panel If you are unable to get anything except 2 red sensors add saline to the reference and other sensors or try the alternate reference locations swap the reference sensors with the rubber comfort pads located directly behind the ears making sure the reference sensors contact directly onto the bare skin on the bony bump Signal Quality Screen Your objective is to achieve as many green lights as possible using the EPOC Control Panel and adjusting the position of the various arms accordingly See full User Manual Document contained on the CD for detailed instructions Note that the EPOC will still function with some sensor locations showing yellow or orange and will even cope with a few red or black however the detections will be less reliable in this state Often the contact quality will gradually improve after a few minutes use so dont be too discouraged if setup is not perfect at first CC EPOC Control Panel Application Tool Connect Help
13. socket Make sure the gold contact plate is clean and there is nothing trapped in the socket which could affect the contact The gold contacts inside the socket consist of three spring tabs which bend slightly upwards towards the sensor Make sure they are not bent away damaged or dirty Swap a different sensor into that location from somewhere that is known to be working This will eliminate a faulty sensor Please contact Customer Service if you cannot resolve this problem and the location seems to be failing for each fitting and all users If you have other problems or your problem is not rectified by the above procedures please check the updated Troubleshooting information visit our Live Chat Support or email hello emotiv com for further assistance EMOTIV EPOC USER MANUAL 44
14. usual reference locations and place them in the sockets recently vacated by the RUBBER COMFORT PADS You can put the COMFORT PADS into the original reference sockets or leave them out if you prefer Make sure you don t lose them if you choose to leave them out Make sure the sensors are sufficiently damp and repeat the above procedure taking care to locate the new reference sensors onto a patch of bare skin on or near the bony lump located just behind the ear flap Within a few seconds the sensors should come to life especially if you press gently on some of the other sensors for a few seconds One or both of the sensors immediately adjacent to the ears remains black These sensors are located on the main body of the Arm assembly closest to the arm pivot point They detect activity in the temporal lobes and are known as T7 left side and T8 right side A combination of the shape of the arm assembly and the user s head shape particularly long narrow heads with relatively flat sides can sometimes result in these sensors failing to touch the head being held off by some of the other sensors Check that the sensors are clean and attached properly as per the general comments in the next section Check that the sensors are clean and attached properly as per the general Remove the RUBBER COMFORT PAD including the plastic holder from the side or sides where the contact cannot be achieved The neuroheadset can be worn comfortably without th
15. Emulator ZIN Headset Setup Guide Step 1 Before putting on the Emotiv headset ensure that each of the 16 electrode recesses are fitted with a moist felt pad If the pads are not already moist wet them with saline solution before inserting into the headset or alternatively use a medicine dropper to carefully moisten the pads while already in place Step 2 Switch on the Emotiv headset and verify that the built in battery is charged and is providing power by looking for the blue LED located near the power switch at the back of the headset If the headset battery needs charging then set the power switch to the off position and plug the headset into the Emotiv battery charger using the mini USB cable provided with the headset Allow the headset battery to charge for at least 15 minutes before trying again Step 3 Verify that the Wireless Signal reception is reported as Good by looking at the Engine Status box in the Emotiv Control Panel If itis not make sure that the Emotiv Dongle is inserted into a USB port on your computer and that the single LED on the top half of the dongle is on continuously or flickering very rapidly If the LED is blinking slowly or is not illuminated then remove the dongle from the computer reinsert it and try again Remove any metallic or dense physical obstructions located near the dongle or the headset and move away from any powerful sources of electromagnetic interference such as microwave ovens or high power
16. Press CTRL SHIFT M EMOTIV EPOC USER MANUAL 40 4 0 EMOTIV Trouble Shooting and Help Transceiver Dongle lights don t work Should see either one slow flashing LED if unpaired or one bright and one dim LED if paired Try different USB port different computer Check other USB equipment works in same port Possible LED failure carry on regardless Transceiver Dongle not recognized USB ding on insertion stream of Hardware Identifier strings observed on first installation Use only on XP Window Vista and Windows 7 and virtual Windows XP Vista 7 machines in Mac OS X Check Device Manager list as Dongle is inserted and removed Try different USB port different computer If Control Panel is running it will ask for User Profile selection when the Transceiver Dongle is recognized whether the neuroheadset is paired or not Does not pair Transceiver Dongle switches from single slow flashing LED to one bright amp one dim LED if correctly paired Check for blue LED on neuroheadset recharge neuroheadset if absent Hold neuroheadset very close to USB switch off and on Unplug and replace Transceiver Dongle in USB port repeat pairing attempt Obtain a USB male USB female extension cable and plug into the PC Attach the Transceiver Dongle to the extension cable and position in a prominent location away from your PC monitor wireless router and other sources of radio frequency interference Turn off
17. ake sure ou feel a distinct catch as ou rotate the sensor into the socket and the finger tabs are aligned along the axis of each arm All sensors black except RED references directly below ears on Contact Quality map e Start with RUBBER COMFORT PADS in locations directly behind the ears e The primary reference sensor locations are behind the head elevated at about 30 degrees backwards behind the ears see diagram in main section of this manual e Ensure reference sensors and at least one forehead sensor are sufficiently wet e Ensure all sensors are properly located in the neuroheadset receptacles They should not spin or fall out when gently moved e Try to minimize the amount of hair trapped underneath the reference sensors The neuroheadset can be wriggled to allow the sensors to pass through the hair or you can try to displace some of the hair with a pencil or similar EMOTIV EPOC USER MANUAL EMOTIV Gently press reference sensors onto the head for at least 5 seconds then release It may take another 20 seconds or so for the sensors to respond Gently press wet forehead sensor for 5 seconds then release It may take another 20 seconds or so for the sensors to respond If still no signals switch reference sensors to the alternate location as follows remove the RUBBER COMFORT PADS including the plastic holders from their location behind the ears They should twist out just like any of the sensors Move the felt pads from the
18. at the same location 2 1 Charging the EPOC Neuroheadset Battery The Emotiv EPOC Neuroheadset contains a built in rechargeable lithium battery which is designed to run for approximately 12 hours when fully charged To charge the EPOC battery set the power switch to the off position and plug the EPOC Neuroheadset into the Emotiv battery charger using the mini USB cable provided with the EPOC Neuroheadset Using the supplied battery charger a fully drained battery can be recharged to 100 capacity in approximately 6 hours charging for 30 minutes usually yields about a 10 increase in charge The EPOC Neuroheadset contains a status LED located next to the power switch at the back of the headband When the power switch is set to the on position the LED will illuminate and appear blue if there is sufficient charge for correct operation The LED will appear red during battery charging when the battery is fully charged the LED will display green NOTE 1 The Neuroheadset should not be charged when still on the head NOTE 2 Do not expose battery or neuroheadset to prolonged temperatures above 122 F 50 C Damage to the battery or neuroheadset may occur EMOTIV EPOC USER MANUAL 16 EMOTIV 2 2 Use of Saline Hydration Sensor Pack and Felt Inserts Open the Saline Hydration Sensor Pack with the white felt inserts inside The inserts will be mounted in the neuroheadset arms but must be properly wetted with saline solution
19. cations Swap the Comfort Pads with the Reference Sensors as shown Also check that all of the sensor pads are damp Use the Reference Sensors location which gives best overall performance 2 6 EmoEngine Status Panel The top pane of EPOC Control Panel is known as the EmoEngine Status Pane This pane displays indicators that provide real time information about EmoEngine status and EPOC Neuroheadset sensor contact quality It also exposes user profile management controls V EPOC Control Panel Application Tool Connect Help ENGINE STATUS USER STATUS System Status Emotiv Engine is ready Headset User f System Up Time 326 515 fo x Emotiv User epoc control panel Z Wireless Signal Good Batery Power High ecco ADD USER REMOVE USER save user Figure 2 EmoEngine Status Pane EM EMOTIV Engine Status By default the Control Panel will automatically connect to the EmoEngine when launched In this mode it will automatically discover attached USB transceivers and Emotiv EPOC Neuroheadsets There are four status indicators System Status A summary of the general EmoEngine status System Up Time The timestamp in seconds attached to the most recently received EmoState event Generally this corresponds to the length of time that the EmoEngine has been running with an EPOC Neuroheadset connected to the USB receiver Wireless Signal This displays the quality of the connection between the EPOC Neuroheadset
20. ction The Cognitiv detection suite evaluates a user s real time brainwave activity to discern the user s conscious intent to perform distinct physical actions on a real or virtual object The detection is designed to work with up to 13 different actions 6 directional movements push pull left right up and down and 6 rotations clockwise counter clockwise left right forward and backward plus one additional action that exists only in the realm of the user s imagination disappear Cognitiv allows the user to choose up to 4 actions that can be recognized at any given time The detection reports a single action or neutral i e no action at a time along with an action power which represents the detection s certainty that the user has entered the cognitive state associated with that action Increasing the number of concurrent actions increases the difficulty in maintaining conscious control over the Cognitiv detection results Almost all new users readily gain control over a single action quite quickly Learning to control multiple actions typically requires practice and becomes progressively harder as additional actions are added Although EPOC Control Panel allows a user to select up to 4 actions at a time it is important that each user masters the use of the Cognitiv detection one action at a time only increasing the number of concurrent actions after he or she has first gained confidence and accuracy with a lower number of actions
21. d Only actions that have keystrokes allocated will be sent to an application window that is active This is shown in Figure 8 where a smile triggers the keystroke X To make this happen enter the desired keystrokes and carefully choose the trigger condition Note the some Expressions have the option occurs while others have is equal to is greater than is less than Select is greater than and type 0 2 into the condition box which will trigger your smile keystrokes whenever a Smile greater than 20 of full scale is detected EPOC Control Panel Application Tool Emotiv Engine is ready User CR Enoti User z epoc control panel Z a ance apo user Remove user save user Affectiv Suite Cognitiv Suite Mouse Emulator H look left right blink left wink right wink Figure 8 EmoKey Smile detection linked to You can manage and save Emokey mappings using the EmoKey menu at the top of the Control Panel Window Mappings can be loaded or saved and you can also temporarily suspend EmoKey activity using the Activate tick selector in the EmoKey menu EMOTIV EPOC USER MANUAL 29 EMOTIV 3 2 Affectiv Suite The Affectiv Suite of functions measures and displays a wide range of subjective emotional responses Levels of interest excitement and engagement that you experience in a cyber environment are translated into graphical measurements on the con
22. ed radio transmitters WEE Figure 4 Neuroheadset Setup Panel The image on the left side of the panel is a representation of the sensor locations when looking down from above onto the user s head Each circle represents one sensor and its approximate location when wearing the neuroheadset The color of the sensor circle is a representation of the contact quality To achieve the best possible contact quality all of the sensors should show as green Other sensor colors indicate Black No signal Not Acceptable EMOTIV EPOC USER MANUAL EMOTIV Red Very poor signal Not Acceptable Orange Poor signal Yellow Fair signal All Green Ideal signal Green Some Yellows Acceptable Green Black and or Orange Red Not Acceptable EPOC may continue to function with several black or red sensors however many detections will be disabled and others will be less reliable The setup procedure used to achieve good contact quality is outlined below Only after the EPOC Neuroheadset sensor contact quality has been maximised should you move on to other EPOC Control Panel tabs 3 0 Achieving Good Signal Quality STEP 1 Before putting on the EPOC Neuroheadset ensure that each of the 16 electrode sockets are fitted with a sensor unit with a moist felt pad If the pads are not already moist wet them with saline solution before inserting into the neuroheadset using the procedure outlined in Section 2 2 above STEP 2 Sw
23. en user profiles Note EPOC Control Panel will automatically save user profile data to disk when it exits so it is generally not necessary to use the Save Profile button EMOTIV EPOC USER MANUAL 21 Emotiv Engine is ready 87 2078 Good ELE High ecco ADD USER REMOVE USER save user Expressiv Suite Affectiv Suite EMOTIV epoc control panel eC Enter new username Emotiv User Existing Users No saved users exist Remove User Figure 3 Add New User Profile into a USB port on your computer and that the single LED on the top half of the dongle is on continuously or flickering very rapidly If the LED is blinking slowly or is not illuminated then remove the dongle from the computer reinsert it and try again Remove any metallic or dense physical obstructions located near the dongle or the headset and move away from any powerful sources of electromagnetic interference such as microwave ovens or high powered radio transmitters each of the 16 electrode recesses are fitted oist wet them with saline solution before medicine dropper to carefully moisten the pads jat the built in battery is charged and is d near the power switch at the back of the en set the power switch to the off position and ising the mini USB cable provided with the atleast 15 minutes before trying again reported as Good by looking at the Engine make sure that the Emotiv Dongle is inser
24. ese pads for people with this head shape and no harm will come to the connector sockets because they are fully enclosed The change in balance point is usually sufficient to ensure contact occurs In the unlikely event that contact is still impossible to obtain you can use a longer felt pad or use a cotton ball soaked in saline to fill the gap or replace the felt piece EMOTIV EPOC USER MANUAL 43 EMOTIV One or more sensors remain black or red for every fitting and user Check that the sensor is properly located in the socket It should click firmly in place the finger tabs should be aligned along the axis of the arm and it should not freely rotate in the socket Check that the sensor is sufficiently damp for operation Check that the sensor is applying gentle but positive pressure to your head in this location When pressed it should not move inwards You may find that slightly relocating the neuroheadset settles the sensors into a better location Remove the neuroheadset and gently press the felt pad into the sensor It should protrude by no more than 2mm It should also feel damp and be free of obstructions Remove the sensor and inspect it The sensor should have a felt pad on the front side and a domed gold plated metal plate which is visible from the rear side The metal plate should be clean and free of obstructions at least across the central third of the domed section in order to make proper contact when inserted Check the
25. first The saline solution is harmless but allows the felt pads to make good contact with the skull when properly positioned on the head This is a very important step Pour a small amount of saline onto each of the sensors 6 or 7 drops if completely dry Once you have moistened the sensors pour a small amount of saline onto the large white hydrator pad to evenly moisten the entire pad Close the hydrator and allow the sensors to absorb some of the saline You can shake or invert the hydrator unit so that the liquid is evenly distributed and absorbed into the felt pads Note For user comfort the sensor pads should be damp but not dripping wet If the pads do not feel slightly wet you may also place one or two more drops of the solution directly on the pads from the top to speed the process of absorption Following the initial hydration step each of the inserts must be removed from the pack and securely mounted in the EPOC neuroheadset arms by turning the inserts one quarter turn to the right and listen feel for the click If you do not hear or feel the click try again until you do A very firm force may be needed the first couple of times but be careful not to exert excessive force or you may damage the headset arms Practice on the sockets in the hydrator a few times if you are unsure Ensure that each sensor is locked in place Note that the sensor location behind the ears is fitted with a soft rubber comfort pad This should remain in place
26. h one clockwise one quarter turn until you feel a definite click The click indicates each sensor is correctly installed in a headset arm If you have difficulty with this step apply a little more force until you feel the click but be careful not to exert excessive force as damage might occur Please see the Troubleshooting section if the sensors do not click in place easily NOTE When not in use the sensor units should be removed from the headset arms and stored in the hydrator pack for subsequent use EMOTIV EPOC USER MANUAL EMOTIV Pairing the Neuroheadset Insert the supplied USB Transceiver Dongle into one of your computer s USB slots Use a USB extension cable and position the Transceiver in a prominent location away from your monitor and PC to improve poor reception Then turn on the headset using the switch at the bottom end of the headset holding it close to the Transceiver Headset Placement You are now ready to put the EPOC headset on your head Using both hands slide the headset down from the top of your head Place the arms approximately as depicted being careful to place the sensors with the black rubber insert on the bone just behind each ear lobe Correct placement of the rubber sensor is critical for correct operation EMOTIV EPOC USER MANUAL EMOTIV Notice the 2 front sensors should be approximately at the hairline or about the width of 3 fingers above your eyebrows After the headset is in
27. hrough sliders to the right of avatar For each facial expression check the performance of the detection If you feel that the Expressiv detection is not responding readily to a particular expression then increase the sensitivity for that expression If you feel that it is too easy to trigger a particular expression or you are seeing false positive expressions then decrease the sensitivity for that expression Sensitivity can be increased or decreased by moving the sensitivity slider to the right or left respectively Application Tool Connect Help ENGINE STATUS System Status Emotiv Engine is ready Headset User 908 765 Emotiv user epoc control panel Y mo seee Lanousen enove usen save sel Affectiv Suite Cognitiv Suite Mouse Emulator look left right blink left wink right wink raise bow Figure 6 Expressiv Suite Sensitivity Adjustment Panel EMOTIV EPOC USER MANUAL 27 EMOTIV 3 1 3 EmoKey EmoKey links the Emotiv technology to your applications by easily converting detected events into any combination of keystrokes EmoKey is a nonintrusive lightweight background process that runs behind your existing games or applications EmoKey lets you create mappings that define how detections are converted to keystroke combinations Your mappings can then be saved and shared so you can use mappings that your friends have created for your favorite games and software EmoKey mappings can be as
28. ickering very rapidly If the LED is blinking slowly or is not illuminated then remove the dongle from the computer reinsert it and try again Remove any metallic or dense physical obstructions located near the dongle or the headset and move away from any powerful sources of electromagnetic interference such as microwave ovens or high powered radio transmitters a i You are now ready to begin using the EPOC headset If you experience difficulties with initial headset start up fine tuning or operation you may contact Emotiv EPOC Customer Support by live chat or support tickets at www emotiv com EMOTIV EPOC USER MANUAL 10 EMOTIV Introduction to Emotiv EPOC Neuro technology Neuroheadset Fulfill the fantasy of having supernatural powers and controlling the world with your mind For over a millennium mankind has dreamed of the ability to control objects with the power of thought Today that dream has become reality Now you can experience the fantasy of having supernatural powers and controlling the world with your mind Based on the latest developments in neuro technology Emotiv has developed a revolutionary new personal interface for human computer interaction The Emotiv EPOC uses a set of sensors to tune into electric signals produced by the brain to detect player thoughts feelings and expressions and connects wirelessly to most PCs Neuroheadset Features Limited edition design 14 biopotential
29. is device may not cause interference and 2 This device must accept any interference received including interference that may cause undesired operation of this device This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la Classe B est conforme a la norme NMB 003 du Canada EMOTIV EPOC USER MANUAL 13 EMOTIV Europe Australia New Zealand Product Name and Model Emotiv EPOC Model 1 0 Product description EPOC Neuroheadset USB 01 Transceiver Hydrator Pack charger or charge cable conforms to the following Product Specifications and Regulations EMC and Telecom Class B ETSI EN 300 440 2 V1 4 1 EN 301 489 1 EN 301 489 3 AS NZS CISPR22 2009 AS NZS 4268 2008 FCC CFR 47 Part 15C identifiers XUE EPOC01 XUE USBD01 Safety EN 60950 1 2006 IEC 60950 1 2005 2nd Edition AS NZS 60950 1 2003 including amendments 1 2 amp 3 CB Certificate JPTUV 029914 TUV Rheinland The product herewith complies with the requirements of the Low Voltage Directive 2006 95 EC the EMC Directive 2004 108 EC the R amp TTE Directive 1999 5 EC and carries the CE and C Tick marks accordingly EMOTIV EPOC USER MANUAL 14 EMOTIV 1 0 Getting Started EPOC Neuroheadset Kit Components EPOC Neuroheadset Assembly with Rechargeable Lithium battery already installed USB Transceiver Dongle Hydration Sensor Pack with 16 Sensor Units Saline Solution For US customers 50 60Hz 100 250 VAC Ba
30. itch on the EPOC Neuroheadset and verify that the built in battery is charged and is providing power by looking for the blue LED located near the power switch at the back of the neuroheadset If the neuroheadset battery needs charging set the power switch to the off position and plug the neuroheadset into the Emotiv battery charger using the mini USB cable provided with the EPOC Neuroheadset or alternatively through a spare USB socket on your PC using a USB MiniB cable Allow the EPOC Neuroheadset battery to charge for at least 15 minutes before trying again A fully discharged neuroheadset will take up to 6 hours to reach full charge STEP 3 Verify that the Wireless Signal reception is reported as Good by looking at the Engine Status area in the EmoEngine Status Pane described in Section 2 6 If the Wireless Signal status is reported as Bad or No Signal then make sure that the Emotiv Wireless USB Receiver is inserted into a USB port on your computer and that the bright LED and dim flickering data transfer LED on the top half of the receiver are visible If the LED is blinking slowly or is not illuminated then remove the receiver from the computer reinsert it and try again Remove any metallic or dense physical obstructions located near the receiver or the EPOC Neuroheadset and move away from any powerful sources of electromagnetic interference such as microwave ovens large motors or high powered radio transmitters You may a
31. lso attach the USB Transceiver to the end of a USB extension cable in order to position the Transceiver prominently in the space away from potential sources of interference such as monitors and wireless routers STEP 4 Put on the EPOC Neuroheadset by gently pulling apart the headband and lowering the sensor arms onto your head from the top down near the rear of the skull Next slide the neuroheadset forward until the sensors closest to the neuroheadset pivot points are located directly above your ears and as close to your hairline as possible Adjust the fit so that the rectangular EMOTIV EPOC USER MANUAL 24 EMOTIV compartments at the front ends of the headband sit comfortably just above and behind your ears Tilt the neuroheadset so that the two lowest front most sensors are symmetric on your forehead and positioned about 2 to 2 5 inches above your eyebrows Finally check that all sensors are touching your head and if not then fine tune the neuroheadset fit by gently sliding the neuroheadset in small increments until an ideal fit has been achieved STEP 5 Starting with the two sensors just above and about an inch 25mm behind your ears these are reference sensors for which good contact with your scalp is essential adjust the sensors so they make proper contact with your scalp i e show green on the contact quality display If the indicators are Black Check that the sensor has a felt pad fitted Check that the felt pad is pres
32. n excitement over longer time periods typically measured in minutes Engagement is experienced as alertness and the conscious direction of attention towards task relevant stimuli It is characterized by increased physiological arousal and beta waves a well known type of EEG waveform along with attenuated alpha waves another type of EEG waveform The opposite pole of this detection is referred to as Boredom in EPOC Control Panel and the Emotiv API however please note that this does not always correspond to a subjective emotional experience that all users describe as boredom Related emotions alertness vigilance concentration stimulation interest Scoring behavior The greater the attention focus and cognitive workload the greater the output score reported by the detection Examples of engaging video game events that result in a peak in the detection are difficult tasks requiring concentration discovering something new and entering a new area Deaths in a game often result in bell shaped transient responses Shooting or sniping targets also produce similar transient responses Writing something on paper or typing typically increase the engagement score while closing the eyes almost always rapidly decreases the score EMOTIV EPOC USER MANUAL 31 EMOTIV 3 3 Cognitiv Suite The Cognitiv Suite panel uses a virtual 3D cube to display an animated representation of the Cognitiv detection output 3 3 1 Cognitiv Suite Introdu
33. of unintended actions it may also be helpful to emulate other mental states and facial expressions that are likely to be encountered in the application context and environment in which you ll be using Cognitiv For many users providing more Neutral training data will result in better overall Cognitiv performance EMOTIV EPOC USER MANUAL 36 EMOTIV Neutral training must be completed first before any actions can be trained and activated EE Clear Training Button Occasionally you may find that a particular trained action doesn t work as well as it once did This may indicate that the training data used to construct your personalized Cognitiv signature was contaminated by a more recent inconsistent training session or that some characteristics of your brainwaves have changed over time It may also happen that you wish to change the mental imagery or technique that you associate with a particular action In either situation you can use the RESET button to delete the training data for the selected action Keep in mind that doing so will disable the Cognitiv detection until new training data has been recorded for this action 3 3 6 Cognitiv Tips Mental dexterity with the Cognitiv Suite is a skill that will improve over time As you learn to train distinct reproducible mental states for each action the detection becomes increasingly precise Most users typically achieve their best results after training each action several times Over
34. omers or USB charger non US customers e CD Installation Disk for Windows XP or Vista for EPOC consumer headset SDKs are delivered electronically EMOTIV EPOC USER MANUAL EMOTIV Initial charging of headset Make sure the small switch on the rear underside of the headset is set to the Off position before starting Plug the mini USB cable attached to the supplied battery charger into the slot at the top of the headset and to the USB port on your PC or the power cord into a 50 or 60 Hz 100 250 V electrical outlet The Lithium battery can be recharged to 100 capacity in approximately 4 hours depending on the initial state of charge Charging for 30 minutes usually yields about a 10 increase in charge The EPOC Headset contains two status LEDs located at the rear and next to the power switch at the back of the headband When the power switch is set to the on position the rear LED will illuminate and appear blue if there is sufficient charge for correct operation unless charging is in progress The charging LED will appear red during battery charging when the battery is fully charged the charging LED will display green NOTE The Headset should not be charged when still on the head Software Installation Access software from your Emotiv user account MY EMOTIV gt MY DOWNLOADS You will be prompted to enter a serial key and order number found when clicking the key button After software installation start up
35. pen in a similar way to moving a limb or remembering a tune A short latency of up to two seconds in the initiation and cessation of the cube s animated action on screen is typical E EmoKey for Cognitiv Actions Emokey links the Emotiv technology to your applications by easily converting detected events into any combination of keystrokes EmoKey is a nonintrusive lightweight background process that runs behind your existing games or applications EmoKey lets you create mappings that define how detections are converted to keystroke combinations Your mappings can then be saved and shared EMOTIV EPOC USER MANUAL 37 EMOTIV so you can use mappings that your friends have created for your favorite games and software EmoKey can be as complex as linking a lift command to a sequence of keystrokes that trigger a levitation spell in a game To configure a Cognitiv action to EmoKey select the action you wish to link and click on the KEY button to the far right of the Cognitiv Panel Display This will bring up a Configuration Dialogue box as shown in Figure 7 Type into the text box the specific keystroke s you wish to send You can also make the facial expression send a continuous string of keys by checking the Hold the key box There are also options to further configure the Key hold time and Key trigger delay time Once you are satisfied with the settings click the Apply button Emotiv Engine is ready 1336 3 Good High s
36. screen and press GO when you are ready A progress bar will appear as your brainwaves are observed Once training is complete you will be asked to accept or reject the training session by pressing YES or NO Once you accept you will be automatically returned to the Cognitiv Panel Display EMOTIV EPOC USER MANUAL EMOTIV ENGINE STATUS Sd a System Status Emoty Engine is ready Headset User System Up Time 3006 15 Emoty User s Wireless Signal Good MA e VI se Batery P High ccoo ADO USER Lesser user SAVE USER lt Headset Setup Expressiv Suite Affectiv Suite SE Emulator Zr Training Completed e Tani on Neutral s comieted ARE CALIBRATING YOUR SIGNAL FOR NEUTRAL Accept tis taring CLEAR YOUR MIND RELAX AND BE NORMAL FOR SECONDS FOR BEST RESULT Figure 12 Accepting a Training Session When you are ready to begin imagining or visualizing an action you wish to train select the action from the dropdown list Actions that have already been trained are paired with a green checkmark actions with no training data are paired with an orange X During the training process it is very important to maintain your mental focus for the duration of the training period currently 8 seconds Physical gestures such as pushing an imaginary object with one hand may be used to heighten your focus on the intended action but are not required You should also refrain from making substantial head movements or dramatic facial expres
37. sensors with gold plated connectors offer optimal positioning for accurate spatial resolution Gyroscope generates optimal positional information for cursor and camera controls Hi performance wireless gives users total range of motion Dongle is USB compatible and requires no custom drivers Rechargeable Lithium battery provides 12 hours of continuous use EMOTIV EPOC USER MANUAL 11 EMOTIV Safety Please note the following safety considerations CHOKING HAZARD detachable small parts Keep away from small children DO NOT attach the neuroheadset to the charger or USB connector while in use AWAYS remove the neuroheadset during charging and avoid touching the sensors if fitted Although unlikely an insulation failure in the charger or USB source may cause the neuroheadset to become live The neuroheadset will automatically enter sleep mode while attached to the charger so it is not possible to extend use while charging WARNING Radio emissions may interfere with appliances and medical equipment including heart pacemakers and automated medical dosimetry systems Use with caution WARNING Discontinue use if the system becomes uncomfortable to wear or if skin irritation occurs Users are advised not to share sets of sensors to avoid cross infection risks EMOTIV EPOC USER MANUAL 12 EMOTIV Regulatory Requirements FCC Requirements Part 15 This device complies with Part 15 of the FCC Rules Operation is subject to the follo
38. should be recognized and installed automatically by your computer as a USB Human Interface Device Please wait for a moment until Windows indicates that the new hardware is installed and ready to use Hold the Emotiv EPOC close to the USB receiver and turn it on using the switch at the rear of the headband You should see a new steady LED on the receiver which indicates that the neuroheadset has properly paired with the USB receiver and a more dim LED which flashes indicating successful data transfer 2 4 EPOC Control Panel This section explains how to use EPOC Control Panel to explore the Emotiv detection suites Launch EPOC Control Panel by selecting Windows Start Programs Emotiv EPOC Control Panel When the Control Panel is launched for the first time your firewall software if installed on your computer may notify you that the Control Panel is trying to accept connections from the network For proper operation you must allow EPOC Control Panel to use this port by selecting Unblock or a similar option depending on your firewall software WW Windows Securty Alert Name EmotivControlPane lt 4 Publisher Unknown Path C users ames desktop buid emotiveortrolpanel exe Network location Public network What are network locations _ is Figure 1 Windows Firewall warning about EPOC Control Panel select Unblock EPOC Control Panel showcases the capabilities of the Emotiv EPOC Neuroheadset
39. simple as linking the Expressiv smile detection to text characters such as so that chat applications instantly know when you smile Configuring EmoKey To configure a facial expression to EmoKey select the expression you wish to link and click on the Key button next to the Facial Expression description This will bring up a Configuration Dialogue box as shown in Figure 7 Type into the text box the specific keystroke s you wish to send You can also make the facial expression send a continuous string of keys by checking the Hold the key box There are also options to further configure the Key hold time and Key trigger delay time Once you are satisfied with the settings click the Apply button Emotiv Engine is ready Headset d 2911 Emotiv User D epoc control panel Z a k x a App user REMOVE user save user Affectiv Suite Cognitiv Suite Mouse Emulator aA KeySimulationConfigureDialog e EE look left right Hold the key Send hot keys F blink Ecri E At E Shift E Win left wink Key hold time 20 ms Key trigger delay time 20 ms right wink Figure 7 Emokey Configuration Dialogue Box EMOTIV EPOC USER MANUAL 28 EMOTIV Once EmokKey is activated the keystroke s allocated to the facial expression will be marked in the corresponding box An orange highlight will flash in the box to the right of the facial expression description that is being triggere
40. sing firmly against your scalp Then try re moistening the felt pad If problems persist this may indicate a problem with the EPOC Neuroheadset Yellow Orange or Red The sensor has not established a good conductive path with your scalp Check that the felt pad is making comfortable yet firm contact with your scalp Try shifting the neuroheadset slightly back and forth on your head or press gently on the troublesome sensor to improve contact If the contact is adequate ensure that the felt pad is moist If the sensor s indicator color becomes lighter the signal quality is improving If the sensor s indicator color is getting darker the signal quality is deteriorating If problems still persist try parting the hair in the vicinity of the electrode so the felt pad touches your scalp See the TROUBLESHOOTING GUIDE at the end of this manual for more details on how to deal with poor contact STEP 6 Repeat Step 5 for each of the remaining sensors until all of the sensors have adequate contact quality i e are predominantly showing green If at any time the reference sensors located just above and behind your ears no longer have a good connection i e they show RED and most or all of the other sensors turn BLACK immediately restore these sensors to green before proceeding further Try the alternative reference locations behind the ears if you continue to have difficulty with the primary locations Section 2 5 EMOTIV EPOC USER MANUAL
41. sions during the training period as these actions can interfere with the recorded EEG signal Initially the cube on screen will not move as the system has not yet acquired the training data necessary to construct a personalized signature for the current set of actions After Neutral and each enabled action have been trained at least once the Cognitiv detection is activated and the cube will respond to the Cognitiv detection and your mental control in real time Some users will find it easier to maintain the necessary mental focus if the cube is automatically animated to perform the intended action as a visualization aid during training If you think you will benefit from this then you may select the Animate cube according to training action checkbox Otherwise the cube will remain stationary or if you have already supplied training data and the detection is active will be animated by the current detection results for the action being trained while you supply new training data EMOTIV EPOC USER MANUAL 35 EMOTIV Application Tool EmoKey Hep ENGINE STATUS USER STATUS L b ee d System Status Emotiv Engine is ready Meadset User po System Up Time 2759 bag epoc control panel H S Sol y See Power gie L ADO user REMOVE user SAVE USER Headset Setup Expressiv Suite Affectiv Suite cognitiv Suite Mouse Emulator TRAIN PUSH KEEP YOUR THOUGHTS CONSTANT AND CONSISTENT FOR SECONDS FOR BEST RESULT
42. ted 2 8 Sensor Contact Quality Display Accurate detection results depend on good sensor contact and signal quality This display is a visual representation of the current contact quality of the individual EROC Neuroheadset sensors The display is a smaller copy of the contact quality visualization found on the Control Panel s Neuroheadset Setup tab Please see Section 3 0 for more information about fitting the EPOC Neuroheadset and achieving good signal quality EMOTIV EPOC USER MANUAL 22 EMOTIV 2 9 Neuroheadset Set Up The Headset Setup panel is displayed by default when starting EPOC Control Panel The main function of this panel is to display contact quality feedback for the EPOC Neuroheadset s sensors and provide guidance to the user in fitting the EPOC Neuroheadset correctly It is important for the user to achieve the best possible contact quality before proceeding to the other EPOC Control Panel tabs Poor contact quality will result in poor Emotiv detection results although the EPOC will continue to perform moderately well with a small number of missing or lower quality sensors PA EPOC Control Panel Application Tool Connect Help ENGINE STATUS System Status Emotiv Engine is ready d Sikta p Tie mme Emote user epoc control panel Ca Wireless Signal Good Batery Power High ecese ADD USER REMOVE user save user Expressiv Suite Affectiv Suite Cognitiv Suite Mouse
43. the EPOC Control Panel program loading the Headset Setup screen EMOTIV EPOC USER MANUAL EMOTIV Hydrating the Sensors Open the Saline Hydration Sensor Pack with the white felt inserts inside The inserts will eventually be mounted in the headset arms but must be properly wetted with saline solution first Begin wetting each of the felt inserts with the supplied saline solution The felts should be wet to the touch but not soaking wet Note This is standard multipurpose contact lens saline solution and is available from any local drug store in case you run out of solution However the bottle supplied with the kit should be sufficient initially See the User Manual on the EPOC CD setup disk for recommendations Add a few drops of saline to saturate the large white hydrator pad attached to the top cover of the hydrator then close the cover and gently shake the hydrator pack This will maintain the moisture of the felt pads when they are not in use Open the pack and check that each of the pads had been wetted If not fully wetted then add a drop or two of saline to any pads not sufficiently wet using the dropper bottle Be careful not to over wet the pads If you have connection problems add more saline to each felt pad EMOTIV EPOC USER MANUAL EMOTIV Sensor Assembly After the wetting process remove the sensor units with their felt pads from the hydrator pack and insert each one into the black plastic headset arms turning eac
44. to decipher brain signals facial expressions and even mouse control using the in built motion sensors EMOTIV EPOC USER MANUAL 19 EMOTIV 2 5 Placement of Emotiv EPOC Neuroheadset on the Head Carefully expand the EPOC neuroheadset to place it on subject s head Using both hands slide the neuroheadset down from the top of your head Place the arms approximately as depicted being careful to place the sensors with the black rubber insert on the bone just behind each ear lobe Correct placement of the rubber sensor is critical for correct operation If any sensors fall out replace them and ensure they are locked in place The EPOC Neuroheadset should be positioned on the head as indicated by the following illustrations NOTE Caution should be exercised never to bend the arms of the neuroheadset backwards out of their natural curvature Damage may occur A view of a properly located Emotiv EPOC Note that the front sensors are 2 2 5 inches 50 60mm or about three finger widths above the eyebrows The Reference Sensors shown here must have good contact with the subject to assess the Contact Quality of the remaining sensors You many need to press these against the subject s scalp for a short period to establish a good conductive path In the event that the Reference Sensors do not make proper contact all or most sensors black on Control Panel screen the behind ear locations can be used as alternative Reference lo
45. to modify the number and type of enabled actions EMOTIV EPOC USER MANUAL 33 EMOTIV 3 3 3 Cognitiv Training The Cognitiv training process enables the EmoEngine to analyze your brainwaves and develop a personalized signature which corresponds to each particular action as well as the background state or neutral As the EmoEngine learns and refines the signatures for each of the actions as well as neutral detections become more precise and easier to perform CH EPOC Control Panel Application Tool Emokey Help ENGINE STATUS USER STATUS System Status Erop Engine is ready Headset User Beggen 20 7 emer une epoc control panel H Ze Wireless Signal G BateryPower Hh ea ee Lave user nenove usen save user Headset Setup Expressiv Suite Affectiv Suite eene Suite Mouse Emulator WE ARE CALIBRATING YOUR SIGNAL FOR NEUTRAL CLEAR YOUR MIND RELAX AND BE NORMAL FOR SECONDS FOR BEST RESULT Figure 11 Cognitiv Neutral Training in action Pressing the TRAIN button next to the drop down menu activates the user interface controls that support the Cognitiv training process The training process consists of three steps First train a neutral state Neutral training must be completed first before any actions can be trained and activated To train neutral there is nothing in particular that you need to do Simply relax act natural and clear your mind Press the TRAIN button to bring up the training
46. training can sometimes produce a decrease in accuracy although this may also indicate a lack of consistency and mental fatigue Practice and experience will help determine the ideal amount of training required for each individual user If it becomes hard for you to return to neutral i e to stop the cube from moving you should try refreshing your mental state by momentarily shifting your focus away from the screen and relaxing It is easy to become immersed in the experience and to have the Cognitiv actions at the front of your mind while trying to be neutral Successful training relies on consistency and focus For best results you must perform the intended action continuously for the full training period It is common for novice users to become distracted at some point during the training period and then mentally restart an action but this practice will result in poorer results than training with a mental focus that spans the entire training period A common mistake is for users to attempt to force a particular action usually by straining head jaw tongue or neck muscles or squinting These actions will just disguise a poor signature and make the detection difficult to duplicate Try to relax and use your imagination to visualize the intended action especially during training Keep your eyes open if possible so you can see the visual feedback on screen Actions will occur most reliably if the user relaxes and lets the action hap
47. trol panel dials and in some cases into dynamically changing environments within games you are playing EPOC Control Panel Application Tool Connect Help ENGINE STATUS System Status Emotiv Engine is ready System Up Time 374 814 epoc control panel Z Batery Power zeg Set app user Remove user save user Headset Setup Expressiv Suite EERE Cognitiv Suite Mouse Emulator Status OK current excitement calm m engagement disinterest mm meditation m long term Figure 9 Affectiv Suite Panel 3 2 1 Affectiv Suite Introduction The Affectiv Suite reports real time changes in the subjective emotions experienced by the user EPOC Control Panel currently displays three short term and three long term Affectiv detections Meditation Engagement and Excitement Emotions related to Engagement are alertness vigilance concentration stimulation interest Examples of engaging video game events that result in a peak in the detection are difficult tasks requiring concentration discovering something new and entering a new area Deaths in a game EMOTIV EPOC USER MANUAL 30 EMOTIV often result in bell shaped transient responses Shooting or sniping targets also produce similar transient responses Writing something on paper or typing typically increase the engagement score while closing the eyes almost always rapidly decreases the score en Understanding the Affectiv Panel Display
48. ttery Charger For non US customers kit includes USB to USB MiniB battery charging cable providing 5 0V at 0 1A from a standard USB socket on any computer Quick Start Guide All of the components of the Emotiv EPOC Neuroheadset are delivered in our standard shipping box Inside the box you will find all of the components neatly stored for shipping and storage Note Never put the Emotiv EPOC or any of its components back into the packaging until they have dried completely Make sure the Hydrator sensor pack is sealed and is not leaking If wet wipe the seal clean before closing EMOTIV EPOC USER MANUAL 15 EMOTIV 2 0 Minimum Hardware and Software requirements 2 4 GHz Intel Pentium 4 processor or equivalent Microsoft Windows XP with Service Pack 2 Microsoft Windows Vista or Microsoft Windows 7 amp 8 2GB RAM 200 MB available disk space One or two unused USB 2 0 ports depending on the number of EPOC Neuroheadsets you wish to use simultaneously Insert the Installation Disk into you PC disk drive and install the EPOC software and follow the instructions For instructions on Windows 7 any other application issues contact Emotiv Support at hello emotiv com We recommend you download the latest versions of Emotiv software from http www emotiv com store apps to obtain the latest features Up to date versions of all software on the installation disk are available for free download Many other applications are also available
49. unless the normal Reference sensors do not contact properly see below for alternative Reference Sensor location The fully populated neuroheadset should look like this EMOTIV EPOC USER MANUAL 17 EMOTIV After first use the pads should be rewet the next time EPOC is used by using a dropper to wet the sensors and hydrator pad again The sensors should be removed from arms after use and stored in the hydrator unit to keep the sensors moist for subsequent use Note on saline solution When the initially provided saline solution has been exhausted additional saline should be purchased from a local drug store We recommend the use of Multi purpose Contact Lens Solution if possible but do not use Contact Lens Cleaning or Sterilizing Solutions Multi purpose Solution contains non allergenic anti microbial agents which help to keep your sensors fresh and prevent transfer of microbes between users Normal saline between 0 7 and 4 w w sodium chloride may also be used but we recommend adding a small quantity no more than 4 by volume of a household disinfectant such as 70 iso propyl alcohol EMOTIV EPOC USER MANUAL 18 EMOTIV 2 3 USB Transceiver Installation Plug the provided Emotiv USB transceiver into an unused USB port on your computer After one or two seconds you should see a single LED flashing slowly or a single bright LED and another dim LED if the transceiver has already paired with a nearby neuroheadset The transceiver
50. wing two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the radio or television off and on the user is encouraged to try to correct interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on another circuit 4 Consult the dealer or an experienced radio TV technician for help NOTE Modifications not expressly approved by Emotiv could void the user s authority to operate the equipment Canada This device complies with RSS 210 of Industry Canada IC Operation is subject to the following two conditions 1 Th