Home
C-more Color Micro-Graphic Hardware User Manual
Contents
1. With Rotation highlighted press i ENT F5 to show ROTATION Y the current Porvat Node NEN cama ir z orientation Press UP S Reso Faeto Bet F3 and DWN F4 TEPA E Kes to toggle between the STE portrait vertical and landscape horizontal orientation Use the APL F5 function button to apply the selection Note Loading a project to the panel will override the orientation choosen from the System Setup Screens Rotation selection screen The selected orientation is displayed only when in the System Setup Screens 5 12 Comore EAI TCL M Hardware User Manual 2nd Ed Rev A 07 13 Chapter 5 System Setup Screens ET Test Menu Use the UP F3 and DWN F4 function keys to scroll through the list of tests The BAK F1 function key will return you to the previous screen Use the ENT F5 function 7 Seral Por Loop Back key to make your selection once you have the test ames 1 ER highlighted Serial Port Loop Back Test page 5 14 PLC Enquiry Test page 5 15 Buzzer Test page 5 15 Touch Panel Test page 5 16 E Comore EA1 TCL M Hardware User Manual 2nd Ed Rev A 07 13 l 5 13 Chapter 5 System Setup Screens TEST MENU 1 Serial Port Loop Back _ 2 PLC Enquiry Test 3 Buzzer Test 4 Touch Panel Test 5 Display Test RS 232 Lo
2. With PLC Enquiry cu pns Test highlighted TEST MENU zd press ENT F5 to TEST MENU 1 Serial Port Loop Back bring up the screen 1 Serial Port Loop Back 2 PLC En Te N ges cR uina mm ETICA M shown to the right gage 4 Touch Panel Test 4 PLC 5 Display Test If the PLC is 5 Display Test XT ay zJ connected to the E ES BA TES panel press ENT F5 to start the test Four data tests will be performed and indicated as either Test Passed or Test Failed as shown on DirectLogic K Sequence this page The BAK ated Tes Pease 1E F1 key can be Data Test Passed SES pressed to cancel the TE gr 5 test and or returned to the previous screen PLC ENQUIRY TEST With Buzzer Test selection highlighted press ENT F5 to run the test on the internal audible beeper The beeper will sequence up the scale through eight notes and then start over The BAK F1 key can be pressed to cancel the test TEST MENU 1 Serial Port Loop Back 2 PLC Enquiry Test 4 Touch Panel Test 5 Display Test ala Y NOTE The beeper tone is not selectable The beeper function can not be turned on or off from this screen B refer to the Setting menu NOTE When the panel is powered through Port1 from a connect
3. SETUP MENU T a Pressing ENT F5 with Exit highlighted will allow the used SW to decided whether to Exit or not Exit the System Setup Comore EA1 TCL M Hardware User Manual 2nd Ed Rev A 07 13 l 5 5 Chapter 5 System Setup Screens i Information Menu INFORMATION 1 Memory Protocol 3 Extensions 4 Versions LaLa Ev 7 INFORMATION 2 Protocol 3 Extensions 4 Versions 4 A v svr INFORMATION 1 Memory 2 Protocol 3 Extensions 4 Versions INFORMATION 1 Memory 2 Protocol 3 Extensions 4 Versions Pressing ENT F5 with Memory highlighted will show the total memory available memory usage and free memory available for the project Pressing ENT F5 with Protocol highlighted will show the PLC Protocol that has been assigned to the panel and the protocol version Pressing ENT F5 with Extensions highlighted will show if an optional keypad bezel is installed on the panel The example here shows the EA MG6 BZ2 Pressing ENT F5 with Versions highlighted will show the panel model firmware and boot loader versions MEMORY Total 3276800 Bytes Us
4. Setting Clear User Memory With Clear User l ea Memory SETTING J highlighted press SETTING 7 Brightness gt x ENT F5 You will m 2 Touch Key Beep gt i m R Are you sure you 3 Calibration gt U be given the choice want to clear 4 Clear User Memory gt memory 5 Reset to Fact Def 6 Hourglass R ERI to either proceed No F1 Yes F5 Bird with clearing the user memory by pressing F5 for YES or allowed to cancel by pressing F1 for NO Setting Reset to Factory Default With Reset to Factory Default SETTING 1 Brightness gt 2 Touch Key Beep gt 3 Calibration gt 4 Clear User Memory 5 Reset to Factory Def 6 Hourglass 7 Rotation highlighted press ENT F5 Press F5 to restore all settings to factory defaults and clear user SETTING Are you sure you want to clear memory l No F1 Yes F5 memory Press F1 to cancel Factory default values can also be reset by pressing F2 and F4 while cycling power to the panel The Factory Default values are Brightness value of 10 The internal audible beeper enabled Forced touch panel calibration User program cleared from memory Hourglass icon delay of 350 ms Horizontal orientation NOTE User memory is cleared when factory defaults are reset
5. Clear User Memory value The default is 5 Reset to Factory Def 8 Hourglass gt 10 The contrast can be adjusted between l and 16 with 1 being the least contrast and 16 being the greatest SETTING Brightness Current Value MEIN LLs TL Ev fe because the panel is running in Low Power Mode Connect an external 12 24 VDC power source when the EB NOTE When the panel is powered through Port1 from a connected PC the screen brightness is diminished panel is installed in its application for full brightness Comore EA1 TCL M Hardware User Manual 2nd Ed Rev A 07 13 l 5 7 Chapter 5 System Setup Screens Setting Touch Key Beep SETTING 2 Touch Key Beep gt 3 Calibration gt 4 Clear User Memory 5 Reset to Factory Def gt 4llAl v sv With Touch Key Beep highlighted press ENT F5 to TOUCH KEY BEEP show the current Coven Vale En value for the internal beeper The default is ON The UP F3 and DWN F4 function keys can be used to toggle between the ON and OFF state for the beeper enable or disable Use the APL F5 function key to apply the selection System Setup Screens Beep on off selection screen The Beep on off choice can be changed through the B NOTE Loading a project to the panel will override whatev
6. Use the C more Micro Graphic programming software to read the program from the panel iand save a backup copy 5 10 Comore EAI TCL M Hardware User Manual 2nd Ed Rev A 07 13 Chapter 5 System Setup Screens Setting Hourglass SETTING 1 Brightness gt 2 Touch Key Beep gt 3 Calibration gt 4 Clear User Memory 5 Reset to Factory Def 6 Hourglass gt 7 Rotation gt LAILA V LENT The Hourglass selection listed under the Setting menu can be used to either disable the display of the hourglass icon or set the amount of delay time 0 ms to 1000 ms desired before it is displayed With Hourglass highlighted press ENT F5 The UP F3 and DWN F4 function keys scroll through the selections Use the APL F5 function key to apply the selection Explanation An hourglass icon is displayed on the panel anytime a new screen is being loaded until communication is established with the new screen If communication is established before the delay has timed out no hourglass will be displayed The hourglass icon can also be disabled from being displayed HOURGLASS Delay Disable ICON HOURGLASS Delay Disable ICON Comore EA1 TCL M Hardware User Manual 2nd Ed Rev A 07 13 l 5 11 Chapter 5 System Setup Screens Setting Rotation
7. test menu includes options to initiate communication tests of the serial port to test communications with the PLC to test operation of the panel s beeper and to test the touch panel surface Refer to the serial port loop back test section of this chapter for details on loop back connector wiring 5 2 Comore EAI TCL M Hardware User Manual 2nd Ed Rev A 07 13 Chapter 5 System Setup Screens n Accessing the System Setup Screens To access the Setup Menu of the panel System Setup Screens press the panel s BAK F1 and ENT F5 function keys simultaneously for three 3 seconds as shown below The System Setup Screens Setup Menu will be displayed as shown at the bottom of this page Press both the F1 and F5 function keys simultaneously for 3 seconds to bring up the System Setup Screens Setup Menu EBEBEBEBELBLPUIS SETUP MENU Lev ra fen cen urs EA1 TACL EA1 TACL Portrait Landscape EA1 T6CL Mode Mode Landscape Mode EA1 T6CL Portrait Mode Comore EA1 TCL M Hardware User Manual 2nd Ed Rev A 07 13 l 5 3 Chapter 5 System Setup Screens System Setup Screens Flowchart Setup Menu pg 5 5 pg 5 6 pg 5 6 2 Protocol pg 5 6 3 Extensions pg 5 6 4 Versions pg 5
8. 6 emes pg 5 7 2 Touch Key Beep pg 5 8 4 Calibration pg 5 9 5 Clear User Memory pg 5 10 6 Reset to Factory Default pg 5 10 7 Hourglass pg 5 11 __ 8 Rotation pg 5 12 3 Test Menu 1 Serial Port Loop Back Test pg 5 13 pg 5 14 2 PLC Enquiry Test pg 5 15 3 Buzzer Test pg 5 15 4 Touch Panel Test pg 5 16 5 Display Test pg 5 16 Do you want to exit from System Screen No F1 Yes F5 2 Setting pg 5 7 TEEN NEEE pg 5 17 5 4 Cnore EA1 TCL M Hardware User Manual 2nd Ed Rev A 07 13 Chapter 5 System Setup Screens Setup Menu To navigate the different selections under the Setup Menu use the function keys BAK F1 to return to the project seenen d RU screen or previous screen UP F3 to cursor up DWN F4 to cursor down and ENT F5 to enter a selection 1 Information 2 Setting 3 Test Menu 4 Exit Pressing ENT F5 with Information highlighted will take you to the Information menu screen See page 5 6 Pressing ENT F5 with Setting highlighted will take you to the Setting menu screen See page 5 7 v fer semu Pressing ENT F5 with Test Menu highlighted will take you 1 to the Test Menu screen See page 5 15 3 Test Menu 4 Exit
9. SYSTEM SETUP SCREENS In This Chapter lacersiirest prm 5 2 Accessing the System Setup Screens 0 cece cee eee eee eee eens 5 3 System Setup Screens Flowchart 0 ccc cece eee eee eens 5 4 Setup MOM EET 5 5 Information MENUS senten ntc RR A ERR ak Sea a a a aye wae genie ee t 5 6 Setting Menu sei ceo 9 RRERWARAWAARWARORRRRRWEAFRSESPIIRSEEVECDLERETE P A e 5 7 Brighlitness cd iue pae o8 Babee ae ee pie RERTR TRUCK EORR RR Sok dva pd AGL Be dPi 5 7 Touich Key Beep 2 3 5 cetera ae MEM RE RUE RE erae ded 5 8 ebur 5 9 Clear User MEmory ss ses pee RR ERE EXE ER EE E E Er ey 5 10 Reset to Factory Default ep entei ennn a E tera d i aie letus ea ie ur Ad 5 10 Hourglass 3E pPRRSRerPPREENEODDDDDDCIIR MENFE e rr r eeen ede 5 11 Rotation ses esas cema aa aaae b Eq Ue E ENE EEE EEE K e y OR a ear 5 12 Test Menu i52 nieder EC 3E airea tage E obra i a e ele eet ane ita aed 5 13 Serial Port2 Loop Back Test 6 cece EEE EEE EEE ESES 5 14 PLC Enquiry Test issu p ERRARE RE Y ie bee eee mno REDE RE ae CE RSS GR 5 15 Buzzer lest esee REE GE Ske RR URGE OR E RR e EU e dos 5 15 Touch Panel TeSt s ss seess cepe er eR EA PER ee eR RR kee ee ee 5 16 Display Test iiie ese RR eme Gea EEN a wea Y E Gk He rr ea eek 5 16 Chapter 5 System Setup Screens C O Introduction The C more Micro Graphic panels include a series of built in System Setup Screens that allow the user to view detailed information about the pane
10. age 0 Bytes Free 3276800 Bytes PROTOCOL Protocol Type K Sequence Version 2 1 0 2 EXTENSIONS Detected Devices Bz2 VERSIONS Model Firmware Boot Loader NOTE Software and Firmware Version 3 0 or later is required with model EA1 T4CL Version 2 5 or later is required with model EA1 T6CL Available for free download at www automationdirect com 5 6 V MOre EA1 TCL M Hardware User Manual 2nd Ed Rev A 07 13 Chapter 5 System Setup Screens ET Setting Menu Use the UP F3 and DWN F4 function keys to scroll through the list of settings The BAK F1 function key will SETTING i return you to the previous screen Use the ENT F5 ties 2 function key to make your selection once you have the 2 Touch Key Beep gt s scala a setting highlighted 4 Clear User Memory 5 Reset to Factory Def 6 Hourglass gt We The Setting screen includes the following 7 Rotation gt Brightness page 5 7 Touch Key Beep page 5 8 Calibration page 5 9 E Clear User Memory page 5 10 Reset to Factory Default page 5 10 Hourglass page 5 11 Rotation page 5 12 Setting Brightness With Brightness highlighted press ENT F5 to bring up the screen PAE mI showing the current 3 Calibration 4
11. ed PC the screen brightness is diminished because the panel is running in Low Power Mode Connect an external 12 24 VDC power source when the panel is installed in its application for full brightness Comore EA1 TCL M Hardware User Manual 2nd Ed Rev A 07 13 l 5 15 Chapter 5 System Setup Screens Test Menu Touch Panel Test With Touch Panel Test highlighted press ENT F5 to bring up the ee screen shown to the 2 PLO Enguity Test right Touch any area of m Lt the screen to visualize the active area of the touch screen If the touch panel area is working properly the screen will blacken at the area touched Use this test to identify any area that is not responding properly Press any key F1 to F5 to return to the Test Menu Test Menu Display Test TEST MENU 4 A With Display Test highlighted press ENT F5 to bring up the screen shown to the 2 PL Enquiry Test right After a few 3 Buzzer Test 4 Touch Panel Test le creme qm J gt seconds a scrolling RGB EET color test will begin Use this test to identify any area that is displaying colors incorrectly Press any key F1 to F5 to return to the Test Menu TEST MENU 5 16 Comore EAI TCL M Hardware User Manual 2nd Ed Rev A 07 13 Chapter 5 System Setup Screens Exit With Exit highlighted press ENT F5 to brin
12. er selection is chosen for the beeper from the System Setup Screens after a project is loaded 5 8 Comore EAI TCL M Hardware User Manual 2nd Ed Rev A 07 13 Chapter 5 System Setup Screens Setting Calibration SETTING 1 Brightness 2 Touch Key Bee 4 Clear User Memory 5 Reset to Factory Def 6 Hourglass 7 Rotation With Calibration highlighted press ENT F5 to bring up the first calibration screen as shown on the right Touch the cross in the upper left corner as accurately as you can When the screen is touched the cross will move to each corner and finally to the center of the screen If the touch points are within the built in calibration tolerance the final screen will allow you to either save and quit from the calibration procedure or allow you to retry If the points that were touched are not within the calibration tolerance you will be returned to the first calibration screen and will need to start over Press Cross Mark Panel will not Communicate in this mode Press F1 to Quit Press Cross Mark Panel will not Communicate in this mode Press F1 to Quit Press Cross Mark Press F1 to Quit F5 to Save amp Quit F1 to Retry Comore EA1 TCL M Hardware User Manual 2nd Ed Rev A 07 13 Chapter 5 System Setup Screens i M M
13. g up the screen shown to the left You will be given the choice to either proceed with exiting the System Setup Screens by pressing F5 for YES or allowed to cancel by pressing F1 for NO You will be returned to the project screen if answering YES SETUP MENU lt j a v v If there is no user program loaded into the panel then a NO E USER PROGRAM message as shown to the left will be displayed SETUP MENU 1 Do you want to 4 exit from System NO USER PROGRAM No F1 Yes F5 Comore EA1 TCL M Hardware User Manual 2nd Ed Rev A 07 13 l 5 17
14. l adjust features test various functions of the panel clear memory and reset all values and conditions back to the original factory defaults The following is presented to give the user a detailed step by step look at e How to access the System Setup Screens e What adjustments and features are available e When and why the feature may need to be adjusted or used e How to adjust and or interrupt the features The System Setup Screens are split into three categories to make it easy for the user to view information make adjustments or test the panel The three Setup Menu selections are Information Here you will find the panel model number detailed information about the panel s available memory and usage the protocol being used by the panel if an optional keypad bezel is installed and version information for the firmware and boot loader Setting This is the area for adjusting the brightness of the display enabling or disabling the internal beeper calibrating the touch panel clearing the user memory resetting all of the settings back to the factory defaults and setting the loading screen hourglass icon delay time or disabling the display of the hourglass icon The Setting factory default values are Brightness value of 10 The internal audible beeper enabled Forced touch panel calibration User program cleared from memory Hourglass icon delay of 350 ms Horizontal display area orientation Test Menu The
15. op back Connector User Constructed 15 pin D sub 33 RxD male 8 5 RTS Wiring Diagram RS 422 485 Loop back Connector User Constructed mr CTS 15 pin D sub 8 5 RTS male 9 5 RXD ress 105 RxD mre Wiring Diagram Test Menu Serial Port Loop Back Test With Serial Port Loop Back Test highlighted press ENT F5 to bring up the screen shown to the right At this point either connect the RS 232 loop back connector or the RS 422 485 loop backconnector depending on which type of communications connection is being used and press ENT F5 to start the test If the test is passing the Receive Counts will equal the Bytes Sent If the serial port is not working then the Error Counts will equal the Bytes Sent The RTS CTS signals will also show either pass or fail as shown to the right The test will continue until the BAK F1 key is pressed TEST MENU Serial Port Loop Back Use Loop Back Connector and Press ENT 1 2 3 4 5 4 A Yv LOOP BACK TEST Serial Port Bytes Sent 124 Rev Counts 124 Err Counts 0 RTS CTS pass ESC LOOP BACK TEST Serial Port Bytes Sent 124 Rev Counts 0 Err Counts 124 RTS CTS ESC 5 14 Comore EA1 TCL M Hardware User Manual 2nd Ed Rev A 07 13 Chapter 5 System Setup Screens Test Menu PLC Enquiry Test
Download Pdf Manuals
Related Search
Related Contents
manual - Linea Acessórios CentreCOM x230シリーズ 取扱説明書 107- LAVE-GLACE Performance Perspectives GP-EXT External USB Printer User`s Manual Manual del usario v1.3 A X I S 5 6 0 0 Copyright © All rights reserved.
Failed to retrieve file