Home

Product Manual

image

Contents

1. TIGHTEN ALL FITTINGS COUPLING CAUTION AIR SUPPLY PUMP MUST BE PLACED IN A CLEAN AIR ENVIRONMENT WHERE BREATHABLE GRADE D AIR CAN BE ASSURED AT ALL TIMES 28 OSHA Occupational Safety amp Health Administration U S Department of Labor OSHA Regulations Standards 29 CFR 1910 1910 134 Respiratory Protection Standard Number 1970 134 Standard Title Respiratory Protection Subpart Number Subpart Title Personal Protective Equipment Produced by USDOL OSHA Directorate of Safety Standards amp Directorate of Health Standards Maintained by USDOL OSHA OCIS a Permissible practice a 1 n the control of those occupational diseases caused by breathing air contaminated with harmful dusts fogs fumes mists gases smokes sprays or vapors the primary objective shall be to prevent atmospheric contamination This shall be accomplished as far as feasible by accepted engineering control measures for example enclosure or confinement of the operation general and local ventilation and substitution of less toxic materials When effective engineering controls are not feasible or while they are being instituted appropriate respirators shall be used pursuant to this section a 2 Respirators shall be provided by the employer when such equipment is necessary to protect the health of the employee The employer shall provide the respirators which are applicable and suitable for the purpose
2. OPERATION MANUAL gt SAFETY CORP When Protection Counts SUPPLIED AIR SYSTEMS MODELS 9800 30 9800 32 ONE MAN FULLFACE SYSTEM 1 4 HP ONE MAN HALFMASK SYSTEM 1 4 HP 9800 00 9800 12 ONE MAN FULLFACE SYSTEM 1 2 HP ONE MAN HALFMASK SYSTEM 1 2 HP 9800 02 9800 22 TWO MAN FULLFACE SYSTEM 3 4 HP TWO MAN HALFMASK SYSTEM 3 4 HP 9800 40 9800 42 FOUR MAN FULLFACE SYSTEM 1 1 2 FOUR MAN HALFMASK SYSTEM 1 1 2 HP READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE USING THESE PRODUCTS WORKERS WHO HAVE BECOME SENSITIZED TO ISOCYANATES SHOULD NOT WORK WITH OR AROUND ISOCYANATES 3031 GARDENIA AVENUE LONG BEACH CA 90807 562 427 2775 FAX 562 427 4646 www sassafety com CUSTOMER ACCEPTANCE AND WARRANTY POLICY I the undersigned purchaser may be signed by either owner or shop manager of an SAS Safety Corp Supplied Air System or pump agree that have thoroughly read and understand the Instruction Manual for the safe operation of the air supply system By signing and returning this acceptance form acknowledge that did not try and operate the system before studying the manual and further agree to continue to follow the recommended guidelines for safe operation per OSHA 29CFR 1910 134 also know that can telephone SAS at any time with any questions concerning the Safe operation of the air supply system I further agree that there will be no warranty adjustments by SAS until return this signed ac
3. PART NUMBER DESCRIPTION 9700 01 INTAKE FILTER ELEMENT 9700 02 EXHAUST FILTER ELEMENT 9700 03 PRESSURE RELIEF VALVE 9700 04 PRESSURE GAUGE 9700 05 CARRYING HANDLE 9700 06 4 RUBBER FEET W NUTS amp BOLTS 9700 07 ELECTRIC CORD W GROUND PLUG 9700 08 INTAKE FILTER ASSEMBLY 9700 09 EXHAUST FILTER ASSEMBLY 9700 10 1 4 NPT MALE COUPLER 0200 022 3 8 BRASS T 0200 03 3 8 HEX NIPPLE 9700 11 PUMP CLEANING SOLUTION Not Shown 9700 25 INLET HOSE KIT 25 ft Not Shown 9700 30 INLET HOSE KIT 25 ft Not Shown 9700 50 SERVICE KIT VANES FILTER 8 PUMP CLEANER Not Shown Warning Exhaust filter DOES NOT REMOVE dangerous organic vapors or gases DO NOT USE this equipment if organic vapors or gases are present If this air pump is to be used as a breathing air source the air inlet MUST be located ina CLEAN AIR area where breathable air can be assured at all times 14 1 1 2 OIL LESS AIR PUMP MOTOR OPEN TYPE NOT EXPLOSIVE PROOF 115V SINGLE PHASE 60HZ INTAKE FILTER ELEMENT EXHAUST FILTER ELEMENT PRESSURE RELIEF VALVE PRESSURE GAUGE 3 4 HEX NIPPLE PUMP CLEANING SOLUTION Not Shown INLET HOSE KIT 25 ft Not Shown INLET HOSE KIT 25 ft Not Shown Warning Exhaust filter DOES NOT REMOVE dangerous organic vapors or gases DO NOT USE this equipment if organic vapors or gases are present If this air pump is to be used as a breathing air source the air inlet MUST be located ina CLEAN
4. Repairs The employer shall ensure that respirators that fail an inspection or are otherwise found to be defective are removed from service and are discarded or repaired or adjusted in accordance with the following procedures h 4 i Repairs or adjustments to respirators are to be made only by persons appropriately trained to perform such operations and shall use only the respirator manufacturer s NIOSH approved parts designed for the respirator h 4 ii Repairs shall be made according to the manufacturer s recommendations and specifications for the type and extent of repairs to be performed and h 4 iii Reducing and admission valves regulators and alarms shall be adjusted or repaired only by the manufacturer or a technician trained by the manufacturer i Breathing air quality and use This paragraph requires the employer to provide employees using atmosphere supplying respirators supplied air and SCBA with breathing gases of high purity i 1 The employer shall ensure that compressed air compressed oxygen liquid air and liquid oxygen used for respiration accords with the following specifications 1 i Compressed and liquid oxygen shall meet the United States Pharmacopoeia requirements for medical or breathing oxygen and 1910 134 i 1 ii i 1 ii Compressed breathing air shall meet at least the requirements for Grade D breathing air described in ANSI Compressed Gas Association Commodity
5. written description of any modifications 2 0100 827 Rev 05 06
6. polycarbonate lens with an anti fog coating on the inside and an anti scratch and solvent resistant coating outside Peel off lens covers are available Both half mask and full face respirators features a heavy duty nylon web belt and storage bag Oil Less Carbon Vane Air Pump The oil less air pump produces completely oil free air and does not generate carbon monoxide oil vapor or oil mists The 115V pump comes with intake and exhaust filters pressure relief valve pressure gauge and airline couplings CAUTION PUMP MUST BE PLACE IN A CLEAN AIR ENVIRONMENT WHERE BREATHABLE AIR CAN BE ASSURED AT ALL TIMES If clean air intake cannot be guaranteed a remote air intake may be used to assure safe breathable air for the user Pump must not be operated in potentially explosive atmosphere Respiratory Protection Program Item No HP Max No of Max No of PSI CFM Respirators Hoods OSHA requires a Respiratory Protection Program be implemented The SAS Instruction Manual outlines compliance requirements for employer and user NOT TO BE USED IN ATMOSPHERES IMMEDIATELY DANGEROUS TO LIFE OR HEALTH All products listed comply with the standards of the Occupational Safety and health Administration OSHA assuming that the materials are used as designed and engineered in accordance with instructions OIL LESS AIR PUMP ASSEMBLY INSTRUCTIONS 9805 00 OIL LESS AIR PUMP PUMP IS COMPLETELY ASSEMBLED AT FACTORY RUBBER FEET P N
7. 134 place air pump where air intake could be contaminated by spray booth exhaust other spraying operations i e primer application etc mixing operations auto exhausts etc place oil less air pump inside spray booth or in the same area in which you are spraying use 9805 00 1 4 amp 1 3hp or 9810 00 1 2hp oil less air pump for 2 man application run oil less air pump without breathing air line and mask attached This will cause pump to over heat and shut off use 9805 00 1 4 amp 1 3hp oil less pump for hood type respirator use ungrounded electrical receptacles use ANY electrical extension cords close off pressure relief value completely This will cause pump to over heat and shut off use respirator and airline in any combination other than in the approved NIOSH configurations before start up unscrew aluminum cup on exhaust filter assembly and check that exhaust filter in firmly seated in place Replace aluminum cup and tighten firmly before start up check intake filter to be sure it is secured to pump housing change intake filter and exhaust filer every 90 to 100 running hours or if pressure drops below recommendations place air inlet pump in a clean air environment where breathable air can be assured at all times check pressure gauge for a minimum 4 0 PSI while air is flowing into supplied air respirator Pressure relief valve is factory set to deliver more than the minimum OSHA required 4 0 CFM
8. AIR area where breathable air can be assured at all times 15 START UP If the motor fails to start or slows down significantly under load shut off and disconnect from power supply Check that the voltage is correct for motor and the motor is turning in the proper direction Vane life will be drastically reduced if motor is not operating properly Vanes can break or be damaged it motor pump runs in the wrong direction Motors are equipped with thermal protector that turns current of automatically when to mechanical or electrical overloads Also check the wiring instructions on motor case or on thermal plate cover LUBRICATION CAUTION NEVER LUBRICATE DRY OIL LESS AIR PUMPS The carbon vanes and grease packed bearing s require NO oil FLUSHING Flushing this product to remove excessive dirt foreign particles moisture or oil that occurs in the operating environment will help to maintain proper vane performance Most pump troubles can be corrected by flushing solvent rather than by taking apart A noisy or inefficient pump is frequently nothing more serious than vanes stuck in a rotor slot due to foreign material dust and or dirty filters CAUTION Recommended commercial solvents for SAS pumps are Loctite Safety Solvent Inhibisol Safety Solvent and Dow Chemical Chlorothane In the event one of the above are not available use any NON FLAMMABLE NON TOXIC NON PETROLEUM BASE INDUSTRIAL CLEANING SOLVENT SAS PUMP FLUSHING LIQU
9. Specification for Air G 7 1 1989 to include 1 1 11 Oxygen content v v of 19 5 23 5 Hydrocarbon condensed content of 5 milligrams per cubic meter of air less 44 Carbon monoxide CO content of 10ppm or less Carbon dioxide content of 1 000 ppm less i 1 ii E Lack of noticeable odor i 2 The employer shall ensure that compressed oxygen is not used in atmosphere supplying respirators that have previously used compressed air i 3 The employer shall ensure that oxygen concentrations greater than 23 5 are used only in equipment designed for oxygen service distribution i 4 The employer shall ensure that cylinders used to supply breathing air to respirators meet the following requirements i 4 i Cylinders are tested and maintained as prescribed in the Shipping Container Specification Regulations of the Department of Transportation 49CFR part 173 and part 178 i 4 ii Cylinders of purchased breathing air have a certificate of analysis from the supplier that the breathing air meets the requirements for Grade D breathing air and i 4 iii The moisture content in the cylinder does not exceed a dew point of 50 degrees F 45 6 deg C at 1 atmosphere pressure i 5 The employer shall ensure that compressors used to supply breathing air to respirators are constructed and situated so as to i 5 i Pr
10. covered by the warranty and that Survivair neither assumes nor authorizes any other person to assume for it any other warranty The warran ty shall be void if the Serial Number affixed to the apparatus by Survivair is removed obliterated or defaced REGARDLESS OF CAUSE if a product you buy from Gast does not work right Gast will repair or replace it once at no charge for up to one year from the date of ship ment from the factory In the course of repair or replacement Gast may send you written recommendations on how to prevent a problem from happening again Gast reserves the right to with draw this warranty if you do not follow these recommendations Customer is re sponsible for freight charges both to and from Gast in all cases This warranty does not apply to electric motors electrical controls and gasoline engines which Gast obtains from other manufacturers A motor or engine carries only the warranty of the company that makes it THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORAL OR IMPLIED INCLUDING THE WARRANTY OF MER CHANTABILITY AND OF FITNESS FOR ANY PARTICULAR PURPOSE GASTS LI ABILITY IS IN ALL CASES LIMITED TO THE REPLACEMENT PRICE OF ITS PROD UCT GAST SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHETHER CON SEQUENTIAL INDIRECT OR INCIDENTAL ARISING FROM THE SALE OR USE OF ITS PRODUCTS Gast s sales personnel may modify this warranty but only by signing a specific
11. failure of the pump to build up pressure and eventual pump overheating Replace exhaust filter element every 90 to 100 running hours Do not be alarmed if temperature of exhaust air reaches 225 F when running continuously If there is evidence of overheating or excessive noise stop immediately for repairs Keep external surfaces clean for proper heat dissipation Most failures to build up pressure are due to leaks in connecting lines damaged filter jar threads collapsed air lines dirty filtering elements or sluggish vanes in the pump The latter is generally caused from the pump being operated above its recommended duty and getting too hot 14 amp 1 3 HP OIL LESS AIR PUMP MOTOR OPEN TYPE NOT EXPLOSIVE PROOF 115V SINGLE PHASE 60HZ INTAKE FILTER ELEMENT EXHAUST FILTER ELEMENT PRESSURE RELIEF VALVE PRESSURE GAUGE ELECTRIC CORD W GROUND PLUG PUMP CLEANING SOLUTION Not Shown INLET HOSE KIT 25 ft Not Shown INLET HOSE KIT 25 ft Not Shown SERVICE KIT VANES FILTER 8 PUMP CLEANER Not Shown Warning Exhaust filter DOES NOT REMOVE dangerous organic vapors or gases DO NOT USE this equipment if organic vapors or gases are present If this air pump is to be used as a breathing air source the air inlet MUST be located in a CLEAN AIR area where breathable air can be assured at all times 13 1 2 amp 3 4 OIL LESS AIR PUMP 9820 00 ONLY MOTOR OPEN TYPE NOT EXPLOSIVE PROOF 115V SINGLE PHASE 60HZ
12. hardeners isocyanates epoxy metal cutting fluids latex or any other material DO NOT USE this respirator system It WILL NOT protect you Failure to read understand and follow ALL warnings and instructions provided here in the respirator manual and with the materials you are using paint epoxy pesticides etc may cause INJURY DISEASE or DEATH If you do not understand the instructions and warning DO NOT USE this respirator system If these instructions and warning indicate that you should not use this respirator system or that it will not protect you DO NO USE IT even if conflicting instructions from somewhere else your boss or a paint store for example indicate you can YOU assume responsibility for any damage injury disease or death caused by YOUR failure to follow instructions an d heed warnings 3031 GARDENIA AVENUE LONG BEACH CA 90807 562 427 2775 FAX 562 427 4646 www sassafety com DO DO DO DO DO DO DO DO DO DO DO DO DO DO DO DO IMPORTANT GENERAL SAFETY INSTRUCTIONS use Supplied Air System in any atmosphere immediately Dangerous to Life or Health IDLH and or from which the worker cannot escape without the use of a respirator OSHA 29CFR 1910 134 place oil less air pump in an area that cannot guarantee clean breathable air grade D per OSHA 29CFR 1910
13. intended The employer shall be responsible for the establishment and maintenance of a respiratory protection program which shall include the requirements outlined in paragraph c of this section 1910 134 b b Definitions The following definitions are important terms used in the respiratory protection standard in this section Air purifying respirator means a respirator with an air purifying filter cartridge or canister that removes specific air contaminants by passing ambient air through the air purifying element Assigned protection factor APF Reserved Atmosphere supplying respirator means a respirator that supplies the respirator user with breathing air from a source independent of the ambient atmosphere and includes supplied air respirators SARs and self contained breathing apparatus SCBA units Canister or cartridge means a container with a filter sorbent or catalyst or combination of these items which removes specific contaminants from the air passed through the container 29 Demand respirator means atmosphere supplying respirator that admits breathing air to the face piece only when a negative pressure is created inside the face piece by inhalation Emergency situation means any occurrence such as but not limited to equipment failure rupture of containers or failure of control equipment that may or does result in an uncontrolled significant release of an airborne contaminant Emp
14. use grounded electrical connections GENERAL DESCRIPTION SAS SUPPLIED AIR RESPIRATOR SYSTEMS 9800 30 ONE MAN FULLFACE SYSTEM 1 4 HP 9800 32 ONE MAN HALFMASK SYSTEM 1 4 HP 9812 00 Supplied Air Respirator Full face 9810 02 Supplied Air Respirator Half mask 9852 42 50 ft Breathing Air Line Hose 9852 42 50 ft Breathing Air Line Hose 9850 31 Heavy Duty Nylon Web Belt 9850 31 Heavy Duty Nylon Web Belt 1400 95 Peel Off Lens Cover 1 Single 5111 Peel Off Lens Cover 1 Single 9401 18 Respirator Storage Bag 9401 18 Respirator Storage Bag 9805 00 1 4 amp 1 3 hp Oil Less Carbon Vane Air Pump 9805 00 1 4 amp 1 3 hp Oil Less Carbon Vane Air Pump 9700 56 5 ft Booth Kit Assembly 9700 56 5 ft Booth Kit Assembly 9800 00 ONE MAN FULLFACE SYSTEM 1 2 9800 12 ONE MAN HALFMASK SYSTEM 1 2 HP 9812 00 Supplied Air Respirator Full face 9810 02 Supplied Air Respirator Half mask 9852 42 50 ft Breathing Air Line Hose 9852 42 50 ft Breathing Air Line Hose 9850 31 Heavy Duty Nylon Web Belt 9850 31 Heavy Duty Nylon Web Belt 1400 95 Peel Off Lens Cover 1 Single 5111 Peel Off Lens Cover 1 Single 9401 18 Respirator Storage Bag 9401 18 Respirator Storage Bag 9810 00 1 2 hp Oil Less Carbon Vane Air Pump 9810 00 1 2 hp Oil Less Carbon Vane Air Pump 9700 56 5 ft Booth Kit Assembly 9700 56 5 ft Booth Kit Assembly 9800 02 TWO MAN FULLFACE SYSTEM 3 4 HP 9800 22 TWO MAN HALFMASK SYSTEM 3 4 HP 9812 00 Supplied Air Respirator Full face Qty 2 9810 02 Supplied A
15. 2 micrometers an air purifying respirator equipped with any filter certified for particulates by NIOSH TABLE 1 Assigned Protection Factors Reserved TABLE II Oxygen defident Atmospheres 0 for Altitude ft which the employer may rely oil atmosphere supplying respirators 16 0 19 5 16 4 19 5 17 1 19 5 17 8 19 5 18 5 19 5 19 3 19 5 Above 8 000 feet the exception does not supply Oxygen enriched breathing air must be supplied above 14 000 feet 35 1910 134 Medical evaluation Using respirator may place physiological burden on employees that varies with the type of respirator worn the job and workplace conditions in which the respirator is used and the medical status of the employee Accordingly this paragraph specifies the minimum requirements for medical evaluation that employers must implement to determine the employee s ability to use a respirator e 1 General The employer shall provide a medical evaluation to determine the employee s ability to use a respirator before the employee is fit tested or required to use the respirator in the workplace The employer may discontinue an employee s medical evaluations when the employee is no longer required to use a respirator e 2 Medical evaluation procedures e 2 i The employer shall identify a physician or other licensed health care professional PLHCP to perform medical evaluations using a m
16. 9700 06 AND HANDLE P N 9700 05 MAY BE ORDERED IF DESIRED 9810 00 AND 9820 00 OIL LESS AIR PUMP INSTALL HANDLE TOWARD PUMP FRONT END WITH HANDLE FLANGES ONTO OF MOTOR BASE USE RUBBER FEET INSTALLATION FOR HANDLE SUPPORT INSTALL REMAINING RUBBER FEET WITH NUTS AND BOLTS PROVIDED PARTIAL PUMP ASSEMBLY HAS BEEN COMPLETED AT FACTORY SCREW INLET FILTER ASSEMBLY INTO INLET PORT MARKED IN IF INLET HOSE KITS ARE TO BE USED FOR REMOTE LOCATION OF INLET AIR INSTALL EXHAUST FILTER HOUSING ASSEMBLY WITH PRESSURE GAUGE AND HOSE COUPLING PRE ASSEMBLED AT FACTORY TO OUTLET TEE EXHAUST PORT 9840 00 OIL LESS AIR PUMP PARTIAL PUMP ASSEMBLY HAS BEEN COMPLETED AT FACTORY SCREW INLET FILTER ASSEMBLY INTO INLET PORT MARKED IF INLET HOSE KITS ARE TO BE USED FOR REMOTE LOCATION OF INLET AIR INSTALL EXHAUST FILTER HOUSING ASSEMBLY WITH PRESSURE GAUGE AND HOSE COUPLING PRE ASSEMBLED AT FACTORY TO OUTLET TEE EXHAUST PORT OIL LESS AIR PUMP OPERATING INSTRUCTIONS MODEL 9805 00 9810 00 9820 00 amp 9840 00 FOR SURVIVAIR RESPIRATOR AND AIR LINE ASSEMBLIES PRESSURE RELIEF VALVE IS FACTORY SET AT MINIMUM 4 0 PSI FOR USE WITH 50 TO 100 FOOT AIR SUPPLY LINE DO NOT CLOSE OFF PRESSURE RELIEF WHERE NO AIR CAN ESCAPE IMPORTANT FOR RESPIRATOR SYSTEMS OTHER THAN SAS SAFETY CORP FOR RESPIRATOR AIR LINE SYSTEMS OTHER THAN SAS ADJUST PRESSURE RELIEF VALVE IF NECESSARY USE PRESSURE RELIEF VALVE
17. AS A ADJUSTMENT DEVICE DELIBERATELY BLEED OFF AIR TO ACHIEVE DESIRED GAUGE READING GAUGE READING SHOULD CONFORM TO MSHA NIOSH APPROVED MINIMUMS FOR EACH SPECIFIC RESPIRATOR MODE MANUFACTURER S OWNER S MANUALS OR INSTRUCTIONS WILL SPECIFY THESE PRESSURE RANGES COUPLING MAY NEED TO BE REPLACED ON PUMP IF AIR LINE CONNECTION IS OTHER THAN SAS SAFETY CORP THIS DOES NOT VIOLATE NIOSH APPROVAL DO NOT CHANGE FITTINGS ON HOSE AS THIS COULD NULLIFY RESPIRATOR NIOSH APPROVAL HOW PERFORMANCE AND LONG LIFE FROM SAS PUMPS GENERAL INFORMATION This pump is only to be used for the purpose of pumping air and under NO circumstances be used with any other gases The pump must not be used for the pumping of fluids particles solids or any substance mixed with air particularly combustible substances likely to cause explosions Your rotary pump is a precision product with a clearance of Top 0015 End 0015 for model 0523 1 4 HP amp 1 3HP and Top 003 End 002 for models 0823 and 1023 1 2HP and 3 4HP Foreign particles or excessive dirt and or dust could cause eventual jamming of the pump The unit is built of steel and cast iron and is designed for pumping dry air Consequently any moisture especially when pump stands idle will tend to corrode interior The Carbon Vanes life is between 5 000 15 000 hours depending upon application NEVER lubricate this oil less rotary vane pump The sealed bearing are gre
18. ELINE The length of hoseline to be used will be determined by the job to be done In NOcase may the hose length exceed 100 feet OPERATING INSTRUCTIONS Donning 1 2 7 Connect the air supply hose to the air supply Put the waist belt on tighten the belt snugly around your waist Tuck the Full face mask or Half mask under your arm and attach the clip on end of the low pressure hose downtube coming from your mask to the ring on your waist belt Attach it so the plug on the end of the hose pints rearward Plug the end of the low pressure hose coming from your mask into the hoseline and turn on the air supply Your mask should now be supplying air Don the Full face mask or Half mask 5 1 Full face Mask a Extend all headstraps to their full length b Push the whole headstrap up and over the forehead part of the mask as far as possible Insert your chin into the Face piece first then pull the headstraps down over the back of your head and down as far as they will go 5 2 Half mask a Place the Half mask against your face and pull the cradle headstrap down behind your head Ensure the straps are above your ears b Connect the lower two straps together behind your head Tighten the straps lower straps first then the upper straps The straps must be tight enough so that they securely hold the Full face mask or Half mask on and prevent leakage Do not make them so tight that you become uncomfortable Your res
19. ESCRIPTION Survivair Supplied Air Respirators provide long duration respiratory protection in toxic atmospheres 1 Air is supplied to the facepiece through a hoseline WARNING Selection or use of this respirator must be done in accordance with American National Standard Practices for Respiratory Protection Z88 2 1980 and the Occupational Safety and Health statutes to which you are subjected DO NOT use this facepiece on a pressure demand unit SURVIVAIR Full face Supplied Air Respirators are approved by the Mine Safety and Health Administration MSHA and the National Institute for Occupational Safety and Health NIOSH approval number TC 19C 230 DO NOT wear supplied air respirators in any atmosphere that is immediately dangerous to life or health Atmospheres immediately dangerous to life or health are a Those which the wearer could not breath for short periods b Those from which the wearer could not escape without the aid of the respirator c Those which would have an immediate or delayed adverse effect on health 22 COMPONENTS Each Full face amp Halfmask Supplied Air Respirator consists of the following major components Face piece Assembly Down Tube Assembly Nylon Web Waist Belt 50 ft Breathing Air Supply Line Use only the components having the part numbers listed on the MSHA NIOSH approval plate Use of any other components voids the approval Accessories To extend the utility of the Full face Supplied Ai
20. Filter s dirty X Clean or replace Relief valve set to high X Inspect and adjust Relief valve set to low X Inspect and adjust Plugged vacuum pressure line X X X Inspect and adjust Vanes sticking X Clean or replace Vanes worn X Replace Shaft seal worn X Replace Dust or offset powder in pump X Inspect and clean Motor not wired correctly X Check wiring diagram and line voltage Damaged jar thread X Replace Damaged jar gasket X Replace Plugged pressure line X Inspect and or replace Running to high RPM Inspect and adjust TROUBLE SHOOTING Reason for Problem Low Pressure High Pressure Pump Motor Over eese LL pee 4l eee I X Ix ew TAKE FL 1771 18 CONTROL OF AIR QUALITY FILTER NOT INCLUDED RESPIRATORS MUST BE SUPPLIED WITH CLEAN BREATHABLE AIR AT ALL TIMES OSHA 29 CFR 1910 134 LOCATE OIL LESS AIR PUMP IN A CLEAN ENVIRONMENT WHERE BREATHABLE AIR CAN BE ASSURED AT ALL TIME NOTE IF CLEAN AIR CANNOT BE GUARANTEED AT ALL TIMES USE PART NO 9700 25 INLET HOSE KIT PERMITTING REMOTE LOCATION OF AIR INLET 25 FEET FROM OIL LESS PUMP ADDITIONAL 25 FOOT CONVOLUTED INLET HOSE SECTIONS PART NO 9700 30 MAY BE ADDED TO A MAXIMUM LENGTH OF 250 FEET WITH USE OF 50 ft BREATHING AIR LINE HOSE TO ASSURE QUALITY OF AIR WARNING PLACE INLET FILTER ASSEMBLY WHERE BREATHING AIR CANNOT BE CONTAMINATED BY SPRAY BOOTH EXHAUST PAINT MIXING OPERATIONS OTHER SPRAY OPERA
21. ID 9700 11 FLUSHING PROCEDURES Remove Intake Filter Assembly and Exhaust Port Assembly Flushing should be done while the unit is running and in a well ventilated area Then while wearing proper protection have a clean cloth over the exhaust port marked OUT Spray or pour a small amount of flushing solution in the intake port marked IN Continue flushing until solution coming out exhaust port appears to be clear After all solvent has passed through the pump continue to let the pump run while unseen solution can dissipate into the air then re attach the Intake Filter Assembly to the port marked IN and Exhaust Port Assembly to the port marked OUT Frequent flushing is recommended to help maintain proper vane performance FILTER ELEMENTS Replace Intake and Exhaust Filter every 90 to 100 running hours DISASSEMBLY If foreign matter has entered pump try flushing If this does not eliminate the foreign matter unplug pump remove only the dead end plate and the four vanes DO NOT at any time remove the rotor Wash vanes end plate and pump chamber with solvent see above for correct type of solvents to be used Dry and reassemble DANGER PREVENT EXPLOSIVE HAZARD DO NOT PUMP COMBUSTIBLE LIQUIDS OR VAPORS WITH ANY SAS UNIT FOR MAXIMUM PUMP LIFE USE MINIMUM PRESSURE NEEDED TO DO THE JOB TROUBLE SHOOTING CHART Reason and remedy for Problem Low High Pump Motor Pressure Pressure Overheat Overheat
22. S To maintain this warranty the purchaser must perform maintenance and inspec tions as prescribed in the owner s instruction manual which shall include prompt replacement or repair of defective parts a complete annual overhaul and such other necessary maintenance and repair as may be required according to the use of the equipment in the reasonable judgment of Survivair Parts damaged by misuse negligence or acci dents are excluded from this warranty Rubber components and the face piece lens are also specifically excluded from this warranty Purchaser acknowledges that notwithstanding any contrary term or provision in purchaser s purchase order or other wise the only warranty extended by Survivair is the express warranty contained herein Purchaser further acknowledges that there are NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITA TION THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE that no oral war ranties representations or guarantees of any kind have been made by Survivair its distributors or the agents of either of them that in any way alter the terms of this warranty that Survivair and its distributors shall in no event be liable for any consequential or incidental damages in Cluding but not limited to injury to the person or property of the purchaser or others and from other losses or expenses incurred by the purchaser arising from the use operation Storage or maintenance of the product
23. TIONS AUTO OR OTHER MACHINERY EXHAUST HARMFUL VAPORS AND GASES ETC 4 9700 25 p JI 6 c 3 11000007 IN i SUPPLIED AIR HALFMASK BLUE 1 MODEL 9810 02 NUMBER NUMBER me _ ea je C E pe JF FE SUPPLIED AIR FULL FACE MODEL 9812 00 ITEM PART DESCRIPTION ITEM PART DESCRIPTION NUMBER NUMBER 1 200 10 FACEPIECE STANDARD SILICONE ONLY STANDARD SILICONE ONLY FACEPIECE STANDARD SILICONE ONLY 14 9852 03 5 6 B amp CABLETIE sem Los oem jemmen res nene ncenece earn e feom p es eese e s s ___ 21 USER INSTRUCTIONS LOW PRESSURE SUPPLIED AIR RESPIRATOR TYPE C CONSTANT FLOW CLASS HALFMASK amp FULLFACE RESPIRATOR SAFETY PRECAUTIONS Warnings Causation and Notes used in this manual have the following significance WARNING Maintenance or operation procedures and techniques will result in personal injury or loss of life if not carefully followed CAUTION Maintenance or operation procedures and techniques will result in damage to equipment if not carefully followed NOTE Maintenance or operating procedures and techniques that are considered important enough to emphasize D
24. all be cleaned and disinfected after every each use h 2 Storage The employer shall ensure that respirators are stored as follows h 2 i All respirators shall be stored to protect them from damage contamination dust sunlight extreme temperatures excessive moisture and damaging chemicals and they shall be packed or stored to prevent deformation of the face piece and exhalation valve h 2 ii n addition to the requirements of paragraph h 2 i of this section emergency respirators shall be 42 h 2 ii XA Kept accessible to the work area h 2 ii B Stored in compartments or in covers that are clearly marked as containing emergency respirators and h 2 ii C Stored in accordance with any applicable manufacturer instructions 1910 134 h 3 h 3 Inspection h 3 i The employer shall ensure that respirators are inspected as follows h 3 i A All respirators used in routine situations shall be inspected before each use and during cleaning h 3 i B All respirators maintained for use in emergency situations shall be inspected at least monthly and in accordance with the manufacturer s recommendations and shall be checked for proper function before and after each use and h 3 i C Emergency escape only respirators shall be inspected before being carried into the workplace for use h 3 ii The employer shall ensure that respirator ins
25. ase packed The service life of the carbon vanes will be reduced by petroleum or hydrocarbon products Precision ground vanes take up their own wear and will last thousands of hours depending upon speed and degree of pressure Excessive dirt foreign particles or moisture could cause the vanes to stick in the rotor slots and even break Periodic Flushing could prevent this see page 10 PRODUCT USE CRITERIA Pump only clean dry air and operate at 32 F 104 F 0 C 40 C Protect unit from dirt and moisture Do not pump flamable or explsive gases or use in an atmosphere that contains such gases INSTALLATION WARNING ELECTRICAL SHOCK HAZARD Disconnect electrical power at the circuit breaker or fuse box before installing this product Install this product where it will not come into contact with water or other liquids Install this product where it will be weather protected Electrically ground this product Failure to follow these instructions can result in death fire or electrical shock CAUTION Blocking air flow around the product in any way can cause the product to over heat and shut off MOUNTING This product may be installed in any orientation Mounting the product to a stable rigid operating surface and using shock mounts will reduce noise and vibration INSPECTION Regular inspection cleaning filters and flushing see page 10 may prevent extensive repairs Dirty or clogged intake filter felt can be responsible for
26. ceptance to them at 3031 Gardenia Avenue Long Beach CA 90807 800 262 0200 FAX 800 244 1938 NAME and TITLE ACCOUNT NAME ADDRESS CITY STATE ZIP CODE TELEPHONE GAST MODEL SAS SERIAL DATE CODE SUPPLIER or SALESMAN DATE OF DELIVERY AND INVOICE RECEIVED BY SAS MUST BE RETURNED TO SAS SAFETY CORP TO INITIATE WARRANTY 2 3 15 19 20 21 22 43 44 45 INDEX GENERAL SAFETY INSTRUCTION DO S amp DON T GENERAL DESCRIPTION ASSEMBLY INSTRUCTIONS OIL LESS AIR PUMP OPERATING INSTRUCTIONS OIL LESS AIR PUMP PARTS DESCRIPTION 9805 00 PARTS DESCRIPTION 9810 00 amp 9820 00 PARTS DESCRIPTION 9840 00 MAINTENANCE OIL LESS AIR PUMP TROUBLE SHOOTING CONTROL OF AIR QUALITY PARTS DESCRIPTION 9810 02 HALF MASK PARTS DESCRIPTION 9812 00 FULLFACE USER INSTRUCTIONS SAR RESPIRATORS SPECTACLE KIT INSTALLATION INSTRUCTIONS BOOTH KIT INSTALLATION INSTRUCTIONS OSHA CODE OF FEDERAL REGULATIONS RESPIRATORY PROTECTION PROGRAM SURVIVAIR 8 GAST WARRANTY SAFETY CORP When Protection Counts This respirator system reduces but does not eliminate exposure and inhalation of contami nants it DOES NOT provide complete protection If you are sensitized to paint paint hardeners isocyanates epoxy metal cutting fluid latex or any other material this respirator system WILL NOT protect you If you have ever had breathing problems while or after using or being around paint or pain
27. commendation shall provide only the following information e 6 i A Any limitations on respirator use related to the medical condition of the employee or relating to the workplace conditions in which the respirator will be used including whether or not the employee is medically able to use the respirator e 6 i B The need if any for follow up medical evaluations and 37 e 6 i C statement that the PLHCP has provided the employee with a copy of the PLHCP s written recommendation e 6 ii the respirator is a negative pressure respirator and the PLHCP finds a medical condition that may place the employee s health at increased risk if the respirator is used the employer shall provide a PAPR if the PLHCP s medical evaluation finds that the employee can use such a respirator if a subsequent medical evaluation finds that the employee is medically able to use a negative pressure respirator then the employer is no longer required to provide a PAPR e 7 Additional medical evaluations At a minimum the employer shall provide additional medical evaluations that comply with the requirements of this section if e 7 i An employee reports medical signs or symptoms that are related to ability to use a respirator e 7 ii PLHCP supervisor or the respirator program administrator informs the employer that an employee needs to be reevaluated e 7 iii Information from the respirator
28. dix B 1 Appendix B 2 and Appendix of this section is mandatory 0 2 Appendix D of this section is non mandatory and is not intended to create any additional obligations not otherwise imposed or to detract from any existing obligations 6 1152 Jan 8 1998 63 FR 20098 April 23 1998 50 RESPIRATORY PROTECTION PROGRAM Written standard operating procedures governing the selection and use of respirators shall be established Respirators shall be selected on the basis of hazards to which the worker is exposed The user shall be instructed and trained in the proper use of respirators and their limitations Where practicable the respirators should be assigned to individual workers for their exclusive use Respirators shall be regularly cleaned and disinfected Those issued for the exclusive use of one worker should be cleaned after each day s use or more often if necessary Those used by more than one worker shall be thoroughly cleaned and disinfected after each use Respirators shall be stored in a convenient clean and sanitary location Respirators used routinely shall be inspected during cleaning Worn or deteriorated parts shall be replaced Respirators for emergency use such as self contained devices shall be thoroughly inspected at least once a month and after each use Appropriated surveillance of work area conditions and degree of employee exposure of stress shall be maintained There shall be regu
29. e the PLHCP makes a recommendation concerning an employee s ability to use a respirator e 5 i A A The type and weight of the respirator to be used by the employee e 5 i B The duration and frequency of respirator use including use for rescue and escape e 5 I C The expected physical work effort e 5 i D Additional protective clothing and equipment to be worn and e 5 i E Temperature and humidity extremes that may be encountered e 5 ii Any supplemental information provided previously to the PLHCP regarding an employee need not be provided for a subsequent medical evaluation if the information and the PLHCP remain the same e 5 iii The employer shall provide the PLHCP with a copy of the written respiratory protection program and a copy of this section Note to Paragraph e 5 iii When the employer replaces a PLHCP the employer must ensure that the new PLHCP obtains this information either by providing the documents directly to the PLHCP or having the documents transferred from the former PLHCP to the new PLHCP However OSHA does not expect employers to have employees medically reevaluated solely because a new PLHCP has been selected e 6 Medical determination In determining the employee s ability to use a respirator the employer shall e 6 i Obtain a written recommendation regarding the employee s ability to use the respirator from the PLHCP The re
30. edical questionnaire or an initial medical examination that obtains the same information as the medical questionnaire e 2 ii The medical evaluation shall obtain the information requested by the questionnaire in Sections 1 and 2 Part A of Appendix C of this section e 3 Follow up medical examination e 3 i The employer shall ensure that a follow up medical examination is provided for an employee who gives a positive response to any question among questions 1 through 8 in Section 2 Part A of Appendix C or whose initial medical examination demonstrates the need for a follow up medical examination e 3 ii The follow up medical examination shall include any medical tests consultations or diagnostic procedures that the PLHCP deems necessary to make a final determination e 4 Administration of the medical questionnaire and examinations e 4 i The medical questionnaire and examinations shall be administered confidentially during the employee s normal working hours or at a time and place convenient to the employee The medical questionnaire shall be administered in a manner that ensures that the employee understands its content e 4 ii The employer shall provide the employee with an opportunity to discuss the questionnaire and examination results with the PLHCP 36 5 Supplemental information for the PLHCP e 5 i The following information must be provided to the PLHCP befor
31. event entry of contaminated air into the air supply system i 5 ii Minimize moisture content so that the dew point at 1 atmosphere pressure is 10 degrees F 5 56 deg C below the ambient temperature i 5 iii Have suitable in line air purifying sorbent beds and filters to further ensure breathing air quality Sorbent beds and filters shall be maintained and replaced or refurbished periodically following the manufacturer s instructions 45 i 5 iv Have a tag containing the most recent change date and the signature of the person authorized by the employer to perform the change The tag shall be maintained at the compressor i 6 For compressors that are not oil lubricated the employer shall ensure that carbon monoxide levels in the breathing air do not exceed 10 ppm i 7 For oil lubricated compressors the employer shall use a high temperature or carbon monoxide alarm or both to monitor carbon monoxide levels If only high temperature alarms are used the air supply shall be monitored at intervals sufficient to prevent carbon monoxide in the breathing air from exceeding 10ppm i 8 The employer shall ensure that breathing air couplings are incompatible with outlets for non respirable worksite air or other gas systems No asphyxiating substance shall be introduced into breathing air lines i 9 The employer shall use breathing gas containers marked in accordance with the NIOSH respirator certifica
32. fectiveness of this program c 2 Where respirator use is not required 32 c 1 i An employer may provide respirators at the request of employees or permit employees to use their own respirators if the employer determines that such respirator use will not in itself create a hazard If the employer determines that any voluntary respirator use is permissible the employer shall provide the respirator users with the information contained in Appendix D to this section Information for Employees Using Respirators When Not Required Under the Standard and c 2 ii In addition the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator and that the respirator is cleaned stored and maintained so that its use does not present a health hazard to the user Exception Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering face pieces dust masks c 3 The employer shall designate a program administrator who is qualified by appropriate training or experience that is commensurate with the complexity of the program to administer or oversee the respiratory protection program and conduct the required evaluations of program effectiveness c 4 The employer shall p
33. g water with any detergent that contains effective disinfectants such as quaternary ammonium compounds 3 Heat the solution to 140 160 60 71 1 C 4 Immerse the face piece top first in the cleaning solution Immerse it only until the exhalation valve is covered 5 Using a soft brush gently clean the face piece 6 Rinse the face piece in a fresh water bath and allow it to air dry Mild heat less than 160 F 71 1 may be used to speed up the drying Use of towel to dry the face piece is not recommended unless a clean lint free towel is used 7 Use caution when cleaning the face piece lens Although the outer surface of the lens has a proprietary anti scratch coating it can be damaged through careless or abusive handling Do not attempt to polish out scratches with any abrasive agent as this will only cause further damage to the remaining coating Warm soapy water using Joy Mr Clean Lestoil etc is usually adequate to remove adhering grime Stubborn deposits may require the use of denatured or isopropyl alcohol or other mild solvents DO NOT allow any solvent to come into contact with rubber or plastic parts Use solvents only in a well ventilated area REPAIR Repair of the Supplied Air Respirator by the user is limited to replacement of the components as 25 listed the MSHA NIOSH approval label Disassembly should be performed only to extent necessary to replace the components WARNING Bef
34. gnize medical signs and symptoms that may limit or prevent the effective use of respirators and k 1 vii The general requirements of this section k 2 The training shall be conducted in a manner that is understandable to the employee k 3 The employer shall provide the training prior to requiring the employee to use a respirator in the workplace k 4 An employer who is able to demonstrate that a new employee has received training within the last 12 months that addresses the elements specified in paragraph k 1 i through vii is not required to repeat such training provided that as required by paragraph k 1 the employee can demonstrate knowledge of those element s Previous training not repeated initially by the employer must be provided no later than 12 months from the date of the previous training k 5 Retraining shall be administered annually and when the following situations occur k 5 i Changes in the workplace or the type of respirator render previous training obsolete k 5 ii Inadequacies in the employee s knowledge or use of the respirator indicate that the employee has not retained the requisite understanding or skill or k 5 iii Any other situation arises in which retraining appears necessary to ensure safe respirator use k 6 The basic advisory information on respirators as presented in Appendix D of this section shall be provided by the employer in a
35. hat could affect respirator fit Such conditions include but are not limited to facial scarring dental changes cosmetic surgery or an obvious changes in body weight 38 f 4 If after passing a QLFT or the employee subsequently notifies the employer program administrator supervisor or PLHCP that the fit of the respirator is unacceptable the employee shall be given a reasonable opportunity to select a different respirator face piece and to be re tested 1910 134 f 5 f 5 The fit test shall be administered using an OSHA accepted QLFT or QNFT protocol The OSHA accepted QLFT and QNFT protocols and procedures are contained in Appendix A of this section f 6 QLFT may only be used to fit test negative pressure air purifying respirators that must achieve a fit factor of 100 or less f 7 If the fit factor as determined through an OSHA accepted protocol is equal or greater than 100 for tight fitting half facepieces or equal to or greater than 500 for tight fitting full face pieces the QNFT has been passed with that respirator f 8 Fit testing of tight fitting atmosphere supplying respirators and tight fitting powered air purifying respirators shall be accomplished by performing quantitative or qualitative fit testing in the negative pressure mode regardless of the mode of operation negative or positive pressure that is used for respiratory protection f 1 8 i Qualitative f
36. he chemical state and physical form of the contaminant d 3 iii For protection against gases and vapors the employer shall provide 34 9 3 11 atmosphere supplying respirator 9 3 11 An air purifying respirator provided that 9 3 111 1 1 The respirator is equipped with end of service life indicator ESLI certified by NIOSH for the contaminant or d 3 iii B 2 If there is no ESLI appropriate for conditions in the employer s workplace the employer implements a change schedule for canisters and cartridges that is based on objective information or data that will ensure that canisters and cartridges are changed before the end of their service life The employer shall describe in the respirator program the information and data relied upon and the basis for the canister and cartridge change schedule and the basis for reliance on the data d 3 iv For protection against particulates the employer shall provide d 3 iv A An atmosphere supplying respirator or d 3 iv B An air purifying respirator equipped with a filter certified by NIOSH under 30 CFR part 11 as a high efficiency particulate air HEPA filter or an air purifying respirator equipped with a filter certified for particulates by NIOSH under 42 CFR part 84 or d 3 iv C For contaminants consisting primarily of particles with mass median aerodynamic diameters MMAD of at least
37. his individual is able to perform assistance or rescue activities without jeopardizing the safety or health of any firefighter working at the incident Note 2 to paragraph g Nothing in this section is meant to preclude firefighters from performing emergency rescue activities before an entire team has assembled h h Maintenance and care of respirators This paragraph requires the employer to provide for the cleaning and disinfecting storage inspection and repair of respirators used by employees h 1 Cleaning and disinfecting The employer shall provide each respirator user with a respirator that is clean sanitary and in good working order The employer shall ensure that respirators are cleaned and disinfected using the procedures in Appendix B 2 of this section or procedures recommended by the respirator manufacturer provided that such procedures are of equivalent effectiveness The respirators shall be cleaned and disinfected at the following intervals h 1 i Respirators issued for the exclusive use of an employee shall be cleaned and disinfected as often as necessary to be maintained in a sanitary condition h 1 ii Respirators issued to more than one employee shall be cleaned and disinfected before being worn by different individuals h 1 iii Respirators maintained for emergency use shall be cleaned and disinfected after each use and h 1 iv Respirators used in fit testing and training sh
38. ir Respirator Half mask Qty 2 9852 42 50 ft Breathing Air Line Hose Qty 2 9852 42 50 ft Breathing Air Line Hose Qty 2 9850 31 Heavy Duty Nylon Web Belt Qty 2 9850 31 Heavy Duty Nylon Web Belt Qty 2 1400 95 Peel Off Lens Cover 2 Single 5111 Peel Off Lens Cover 2 Single 9401 18 Respirator Storage Bag 2 9401 18 Respirator Storage Bag 2 9820 00 3 4 hp Oil Less Carbon Vane Air Pump 9820 00 3 4 hp Oil Less Carbon Vane Air Pump 9700 56 5 ft Booth Kit Assembly Qty 2 9700 56 5 ft Booth Kit Assembly Qty 2 9800 40 FOUR MAN FULLFACE SYSTEM 1 1 2 HP 9800 42 FOUR MAN HALFMASK SYSTEM 1 1 2 HP 9812 00 Supplied Air Respirator Full face Qty 4 9810 02 Supplied Air Respirator Half mask Qty 4 9852 42 50 ft Breathing Air Line Hose Qty 4 9852 42 50 ft Breathing Air Line Hose Qty 4 9850 31 Heavy Duty Nylon Web Belt Qty 4 9850 31 Heavy Duty Nylon Web Belt Qty 4 1400 95 Peel Off Lens Cover 2 Single 5111 Peel Off Lens Cover 2 Single 9401 18 Respirator Storage Bag 4 9401 18 Respirator Storage Bag 4 9840 00 1 1 2 hp Oil Less Carbon Vane Air Pump 9840 00 1 1 2 hp Oil Less Carbon Vane Air Pump 9700 56 5 ft Booth Kit Assembly Qty 4 9700 56 5 ft Booth Kit Assembly Qty 4 Supplied Air Respirator SAR The SAS Safety s facemask is molded from silicone rubber for superior comfort and fit The multipoint headstrap is fully adjustable to maintain a comfortable no slip fit The full face mask features a wide view
39. it testing of these respirators shall be accomplished by temporarily converting the respirator user s actual face piece into a negative pressure respirator with appropriate filters or by using an identical negative pressure air purifying respirator face piece with the same sealing surfaces as a Surrogate for the atmosphere supplying or powered air purifying respirator face piece f 1 8 ii Quantitative fit testing of these respirators shall be accomplished by modifying the face piece to allow sampling inside the face piece in the breathing zone of the user midway between the nose and mouth This requirement shall be accomplished by installing a permanent sampling probe onto a surrogate face piece or by using a sampling adapter designed to temporarily provide a means of sampling air from inside the face piece f 1 8 iii Any modifications to the respirator face piece for fit testing shall be completely removed and the face piece restored to NIOSH approved configuration before that face piece can be used in the workplace g Use of respirators This paragraph requires employers to establish and implement procedures for the proper use of respirators These requirements include prohibiting conditions that may result in face piece seal leakage preventing employees from removing respirators in hazardous environments taking actions to ensure continued effective respirator operation throughout the work shift and establishing procedu
40. lar inspection and evaluation to determine the continued effectiveness of the program Persons should not be assigned to tasks requiring use of respirators unless it has been determined that they are physically able to perform the work and use the equipment The local physician shall determine what health and physical conditions are pertinent The respirator user s medical status should be reviewed periodically for instance annually Approved or accepted respirators shall be issued when they are available The respirator furnished shall provide adequate respiratory protection against a particular hazard for which it is designed in accordance with standards established by competent authorities A RESPIRATORY PROTECTION PROGRAM MUST BE IMPLEMENTED PER OSHA 29CFR 1910 134 51 One Warranty Survivair a Division of Comasec Inc warrants to the original owner for a period of one year trom the date of purchase that the Surviviar product will be free from defects in materials and workmanship During this period Survivair will repair or replace defective parts on an exchange basis FO B the factory Santa Ana California allowing no transportation or mileage charges The decision to repair or replace defective parts shall be determined by Survivair VALIDATION To validate this warranty the registration card must be detached completed and returned to Survivair offices within 30 days of purchase CONDITIONS AND EXCLUSION
41. loyee exposure means exposure to a concentration of an airborne contaminant that would occur if the employee were not using respiratory protection End of service life indicator ESLI means a system that warns the respirator user of the approach of the end of adequate respiratory protection for example that the sorbent is approaching saturation or is no longer effective Escape only respirator means a respirator intended to be used only for emergency exit Filter or air purifying element means a component used in respirators to remove solid or liquid aerosols from the inspired air Filtering face piece dust mask means a negative pressure particulate respirator with a filter as an integral part of the face piece or with the entire face piece composed of the filtering medium Fit factor means a quantitative estimate of the fit of a particular respirator to a specific individual and typically estimates the ratio of the concentration of a substance in ambient air to its concentration inside the respirator when worn Fit test means the use of a protocol to qualitatively or quantitatively evaluate the fit of a respirator on an individual See also Qualitative fit test QLFT and Quantitative fit test QNFT Helmet means a rigid respiratory inlet covering that also provides head protection against impact and penetration High efficiency particulate air HEPA filter means a filter that is at least 99 97 efficient in removing mo
42. nd reasonably fits the user d 2 Respirators for IDLH atmospheres d 2 i The employer shall provide for the following respirators for employee use in IDLH atmospheres d 2 i A A full face piece pressure demand SCBA certified by NIOSH for a minimum service life of thirty minutes or d 2 i B A combination full face piece pressure demand supplied air respirator SAR with auxiliary self contained air supply d 2 ii Respirators provided only for escape from IDLH atmospheres shall be NIOSH certified for escape from the atmosphere in which they will be used d 2 iii All oxygen deficient atmospheres shall be considered IDHL Exception If the employer demonstrates that under all foreseeable conditions the oxygen concentration can be maintained within the ranges specified in Table II of this section i e for the altitudes set out in the table then any atmosphere supplying respirator may be used d 3 Respirators for atmospheres that are not IDLH d 3 i The employer shall provide a respirator that is adequate to protect the health of the employee and ensure compliance with all other OSHA statutory and regulatory requirements under routine and reasonably foreseeable emergency situations d 3 i A Assigned Protection Factors APFs Reserved d 3 i B Maximum Use Concentration Reserved d 3 ii The respirator selected shall be appropriate for t
43. ng and the respirator program This information will facilitate employee involvement in the respirator program assist the employer in auditing the adequacy of the program and provide a record for compliance determinations by OSHA 1910 134 m 1 m 1 Medical evaluation Records of medical evaluations required by this section must be retained and made available in accordance with 29 CFR 1910 1020 m 2 Fit testing m 2 i The employer shall establish a record of the qualitative and quantitative fit tests administered to an employee including m 2 i A The name or identification of the employee tested m 2 i B Type of fit test performed m 2 i C Specific make model style and size of respirator tested 48 m 2 i D Date of test and m 2 i E The pass fail results for QLFTs or the fit factor and strip chart recording or other recording of the test results for QNFTs m 2 ii Fit test records shall be retained for respirator users until the next fit test is administered m 3 A written copy of the current respirator program shall be retained by the employer m 4 Written materials required to be retained under this paragraph shall be made available upon request to affected employees and to the Assistant Secretary or designee for examination and copying n Dates 1 Effective date This section is effective April 8 1998 The obliga
44. nodisperse particles of 0 3 micrometers in diameter The equivalent NIOSH 42 CFR 84 particulate filters are the N100 R100 and P100 filters Hood means a respiratory inlet covering that completely covers the head and neck and may also cover portions of the shoulders and torso Immediately dangerous to life or health IDLH means an atmosphere that poses an immediate threat to life would cause irreversible adverse health effects or would impair an individual s ability to escape from a dangerous atmosphere Interior structural firefighting means the physical activity of fire suppression rescue or both inside of buildings or enclosed structures which are involved in a fire situation beyond the incipient stage See 29 CFR 1910 155 Loose fitting face piece means a respiratory inlet covering that is designed to form a partial seal with the face Maximum use concentration MUC Reserved 30 Negative pressure respirator tight fitting means respirator in which air pressure inside the face piece is negative during inhalation with respect to the ambient air pressure outside the respirator Oxygen deficient atmosphere means an atmosphere with an oxygen content below 19 5 by volume Physician or other licensed health care professional PLHCP means an individual whose legally permitted scope of practice i e license registration or certification allows him or her to independently provide or be delegated to the re
45. ny written or oral format to employees who wear respirators when such use is not required by this section or by the employer I Program evaluation This section requires the employer to conduct evaluations of the workplace to ensure that the written respiratory protection program is being properly implemented and to consult employees to ensure that they are using the respirators properly 47 1 1 The employer shall conduct evaluations of the workplace as necessary to ensure that the provisions of the current written program are being effectively implemented and that it continues to be effective 1 2 The employer shall regularly consult employees required to use respirators to assess the employees views on program effectiveness and to identify any problems Any problems that are identified during this assessment shall be corrected Factors to be assessed include but are not limited to 1910 134 I 2 i I 2 i Respirator fit including the ability to use the respirator without interfering with effective workplace performance 1 2 ii Appropriate respirator selection for the hazards to which the employee is exposed 1 2 iii Proper respirator use under the workplace conditions the employee encounters and 1 2 iv Proper respirator maintenance m Recordkeeping This section requires the employer to establish and retain written information regarding medical evaluations fit testi
46. of the respirator g 2 ii The employer shall ensure that employees leave the respirator use area 1910 134 g 2 ii A g 2 ii A To wash their faces and respirator face pieces as necessary to prevent eye or skin irritation associated with respirator use or g 2 ii B If they detect vapor or gas breakthrough changes in breathing resistance or leakage of the face piece or 9 2 ii C To replace the respirator or the filter cartridge or canister elements 40 g 2 iii If the employee detects vapor or gas breakthrough changes in breathing resistance or leakage of the face piece the employer must replace or repair the respirator before allowing the employee to return to the work area 9 3 Procedures for IDHL atmospheres For IDLH atmospheres the employer shall ensure that 9 3 i One employee or when needed more than one employee is located outside the IDLH atmosphere g 3 ii Visual voice or signal line communication is maintained between the employee s is the IDLH atmosphere and the employee s located outside the IDLH atmosphere g 3 iii The employee s located outside the IDLH atmosphere are trained and equipped to provide effective emergency rescue 9 3 iv The employer or designee is notified before the employee s located outside the IDLH atmosphere enter the IDLH atmosphere to provide emergency rescue 9 3 v The employer or designee au
47. ore disassembly make sure that all air is bled from the lines Shut off or deplete the air supply to prevent equipment damage or personal injury To protect your warranty and the MSHA NIOSH certification on the equipment all other repairs must be done only by authorized SURVIVAIR repairmen If there are none at your facility consult your SURVIVAIR distributor for the one nearest you STORAGE After inspection cleaning and necessary repair the Supplied Air Respirator should be stored to protect it against dust sunlight heat extreme cold excessive moisture or damaging chemicals The Supplied Air Respirator should be stored in compartments built for that purpose The compartments should be clearly marked 26 Spectacle Kit 9411 03 FOR USE WITH 9812 00 or 4200 10 MASKS INSTALLATION INSTRUCTIONS 1 TAKE FRAMES AND TEMPLE BARS TO AN OPTICIAN FOR INSTALLATION OF PRESCRIPTION LENSES YOU WILL NEED YOUR PRESCRIPTION FRAMES USE 48mm SIZE LENS ONLY 2 INSERT SPECTACLE TEMPLE BARS INTO HOLES IN TABS ON INSIDE OF MASK SKIRT 3 POSITION SPECTACLES AS DESIRED TABS ON SKIRT 27 BOOTH KIT INSTALLATION REMOVE FITTING WITH PRESSURE GAUGE AND AIR LINE COUPLING FROM PUMP DO NOT DISCARD INSTALL END OF 5 HOSE TO PUMP FOR EACH OUTLET DRILL 9 16 HOLE THROUGH SPRAY BOOTH WALL AT LOCATION DESIRED BRACKET THE BOOTH WALL WITH THE 2 WASHERS SUPPLIED AND INSTALL 5 HOSE TO GAUGE AND AIR COUPLING AS SHOWN BELOW
48. pections include the following h 3 ii A A check of respirator function tightness of connections and the condition of the various parts including but not limited to the face piece head straps valves connecting tube and cartridges canisters or filters and h 3 ii B check of elastomeric parts for pliability and signs of deterioration h 3 iii n addition to the requirements of paragraphs h 3 i and ii of this section self contained breathing apparatus shall be inspected monthly Air and oxygen cylinders shall be maintained in a fully charged state and shall be recharged when the pressure falls to 9096 of the manufacturer s recommended pressure level The employer shall determine that the regulator and warning devices function properly h 3 iv For respirators maintained for emergency use the employer shall 43 h 3 iv A Certify the respirator by documenting the date the inspection was performed the name signature of the person who made the inspection the findings required remedial action and a serial number or other means of identifying the inspected respirator and B Provide this information on a tag or label that is attached to the storage compartment for the respirator is kept with the respirator or is included in inspection reports stored as paper or electronic files This information shall be maintained until replaced following a subsequent certification h 4
49. pirator is now ready to use PERIODIC INSPECTION NOTE The Supplied Air Respirator should be inspected for defects after each use and at least once monthly if it is not used The Supplied Air Respirator should be repaired as necessary cleaned and disinfected and then stored properly to assure that it is maintained in satisfactory working condition A record should be kept of inspection dates and findings 24 INSPECTION 1 WAIST BELT Check the waist belt for broken twisted or excessively frayed straps defective or excessively rusty buckles defective stitching and cuts tears or holes 2 FACEPIECE The face piece skirt and headstrap should be inspected for pliability and signs of deterioration Stretching and manipulating the rubber with a massaging action will keep it pliable flexible and prevent it from taking a set during storage All parts and especially the lens should be clean and free of dirt and dust Examine the buckles to see that they function properly and free of excessive rust Check the face piece for leaks Special attention should be given to the exhalation valve and the joint between the lens and the skirt 3 HOSE Inspect the mask and air supply hose for leaks cuts cracks and abrasions Check the end fittings for tightness CLEANING 1 For sanitary reasons the respirator face piece should be cleaned and disinfected after each use even if it does not look dirty 2 Make a cleaning solution by mixin
50. r respirator the following accessories are offered as option equipment Spectacle Kit 9411 03 Nose Cup Kit Full face 9413 17 Protective Bag 9401 18 Lens Cover Full face 1400 95 Lens Cover Half Mask 5111 PREPARATION FOR USE Air Supply A PURITY Unless safety and health codes in your area specify otherwise air purity must meet t h e requirements of Type 1 Grade D gaseous air set forth in the Compressed Gas Association Commodity Specification for Air G 7 1 The responsibility of maintaining the quality of the air is yours Install purification and monitoring equipment as necessary B PRESSURE Pressure relief valve on SAS pump is factory set for maximum air flow Pressure of the air supply must be maintained within the range specified for the length of air supply line measured at the inlet to the air supply line Refer to respirator manufacturer s recommendation for specific settings WARNING If a compressor is used to supply breathing air the following precautions must be taken A The compressor air intake must be located so that only clean fresh air is drawn into the compressor Be especially careful that toxic gases are not drawn in Locate the air intake away from engine exhausts spray paint exhausts over spray chemical processes and or dust sources B The responsibility for compliance with safety and health codes applicable to you area is YOURS 23 LENGTH OF HOS
51. res for the use of respirators in IDLH atmospheres or in interior structural firefighting situations 39 9 1 Face piece seal protection g 1 i The employer shall not permit respirators with tight fitting face pieces to be worn by employees who have 9 1 1 Facial hair that comes between the sealing surface of the face piece and the face or that interferes with valve function or g 1 i B Any condition that interferes with the face to face piece seal or valve function g 1 ii If an employee wears corrective glasses or goggles or other personal protective equipment the employer shall ensure that such equipment is worn in a manner that does not interfere with the seal of the face piece to the face of the user g 1 iii For all tight fitting respirators the employer shall ensure that employees perform a user seal check each time they put on the respirator using the procedures in Appendix B 1 or procedures recommended by the respirator manufacturer that the employer demonstrates are as effective as those in Appendix B 1 of this section 9 2 Continuing respirator effectiveness 9 2 i Appropriate surveillance shall be maintained of work area conditions and degree of employee exposure or stress When there is a change in work area conditions or degree of employee exposure or stress that may affect respirator effectiveness the employer shall reevaluate the continued effectiveness
52. rovide respirators training and medical evaluations at no cost to the employee d Selection of respirators This paragraph requires the employer to evaluate respiratory hazard s in the workplace identify relevant workplace and user factors and base respirator selection on these factors The paragraph also specifies appropriately protective respirators for use in IDLH atmospheres and limits the selection and use of air purifying respirators d 1 General requirements d 1 i 1 The employer shall select and provide an appropriate respirator based on the respiratory hazard 5 to which the worker is exposed and workplace and user factors that affect respirator performance and reliability d 1 ii The employer shall select a NIOSH certified respirator The respirator shall be used in compliance with the conditions of its certification d 1 iii The employer shall identify and evaluate the respiratory hazard s in the workplace this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard s and an identification of the contaminant s chemical state and physical form Where the employer cannot identify or reasonably estimate the employee exposure the employer shall consider the atmosphere to be IDHL 33 1910 134 d 1 iv d 1 iv The employer shall select respirators from a sufficient number of respirator models and sizes so that the respirator is acceptable to a
53. s are necessary to protect the health of the employee or whenever respirators are required by the employer the employer shall establish and implement a written respiratory protection program with worksite specific procedures The program shall be updated as necessary to reflect those changes in workplace conditions that affect respirator use The employer shall include in the program the following provisions of this section as applicable c 1 i Procedures for selecting respirators for use in the workplace c 1 ii Medical evaluations of employees required to use respirators c 1 iii Fit testing procedures for tight fitting respirators c 1 iv Procedures for proper use of respirators in routine and reasonably foreseeable emergency situations c 1 v Procedures and schedules for cleaning disinfecting storing inspecting repairing discarding and otherwise maintaining respirators c 1 vi Procedures to ensure adequate air quality quantity and flow of breathing air for atmosphere supplying respirators c 1 vii Training if employees in the respiratory hazards to which they are potentially exposed during routine and emergency situations 1910 134 c 1 viii c 1 viii Training of employees in the proper use of respirators including putting on and removing them any limitations on their use and their maintenance and c 1 ix Procedures for regularly evaluating the ef
54. sponsibility to provide some or all of the health care services required by paragraph e of this section Positive pressure respirator means a respirator in which the pressure inside the respiratory inlet covering exceeds the ambient air pressure outside the respirator Powered air purifying respirator PAPR means an air purifying respirator that uses a blower to force the ambient air through air purifying elements to the inlet covering Pressure demand respirator means a positive pressure atmosphere supplying respirator that admits breathing air to the face piece when the positive pressure is reduced inside the face piece by inhalation Qualitative fit test QLFT means a pass fail fit test to assess the adequacy of respirator fit that relies on the individual s response to the test agent Quantitative fit test QNFT means an assessment of the adequacy of respirator fit by numerically measuring the amount of leakage into the respirator Respiratory inlet covering means that portion of a respirator that forms the protective barrier between the user s respiratory tract and an air purifying device or breathing air source or both It may be a face piece helmet hood suit or a mouthpiece respirator with a nose clamp Self contained breathing apparatus SCBA means an atmosphere supplying respirator for which the breathing air source is designed to be carried to the user Service life means the period of time that a respira
55. thorized to do so the employer once notified provides necessary assistance appropriate to the situation 9 3 vi Employee s located outside the IDLH atmospheres are equipped with 9 3 vi A Pressure demand or other positive pressure SCBA s or a pressure demand or other positive pressure supplied air respirator with auxiliarv SCBA and either 9 3 vi B Appropriate retrieval equipment for removing the employee s who enter s these hazardous atmospheres where retrieval equipment would contribute to the rescue of the employee s and would not increase the overall risk resulting from entry or 9 3 vi P C Equivalent means for rescue where retrieval equipment is not required under paragraph g 3 vi B 9 4 Procedures for interior structural firefighting In addition to the requirements forth under paragraph 0 g 3 in interior structural fires the employer shall ensure that 9 4 i Atleast two emplovees enter the IDLH atmosphere and remain in visual or voice contact with one another at all times 41 4 At least two employees are located outside the IDLH atmosphere and 9 4 iii All emplovees engaged in interior structural firefighting use SCBA s Note 1 to paragraph g One of the two individuals located outside the IDLH atmosphere may be assigned to an additional role such as incident commander in charge of the emergency or safety officer so long as t
56. tion standard 42 CFR part 84 Identification of filters cartridges and canisters The employer shall ensure that all filters cartridges and canisters used in the workplace are labeled and color coded with the NIOSH approval label and that the label is not removed and remains legible Training and information This paragraph requires the employer to provide effective training to employees who are required to use respirators The training must be comprehensive understandable and recur annually and more often if necessary This paragraph also requires the employer to provide the basic information on respirators in Appendix D of this section to employees who wear respirators when not required by this section or by the employer to do so k 1 The employer shall ensure that each employee can demonstrate knowledge of at least the following 1910 134 k 1 i k 1 i Why the respirator is necessary and how improper fit usage or maintenance can compromise the protective effect of the respirator k 1 ii What the limitations and capabilities of the respirator are k 1 iii How to use the respirator effectively in emergency situations including situations in which the respirator malfunctions 46 k 1 iv How to inspect put on and remove use and check the seals of the respirator k 1 v What the procedures are for maintenance and storage of the respirator k 1 vi How to reco
57. tions imposed by this section commence on the effective date unless otherwise noted in this paragraph Compliance with obligations that do not commence on the effective date shall occur no later than the applicable start up date n 2 Compliance dates All obligations of this section commence on the effective date except as follows 1910 134 n 2 i n 2 i The determination that respirator use is required paragraph a shall be completed no later than September 8 1998 n 2 ii Compliance with provisions of this section for all other provisions shall be completed no later than October 8 1998 n 3 The provisions of 29 CFR 1910 134 and 29CFR 1926 103 contained in the 29 CFR parts 1900 to 1910 99 and the 29 CFR part 1926 editions revised as of July 1 1997 are in effect and enforceable until October 5 1998 or during any administrative or judicial stay of the provisions of this section n 4 Existing Respiratory Protection Programs f in the 12 month period preceding April 8 1998 the employer has conducted annual respirator training fit testing respirator program evaluation or medical evaluations the employer may use the results of those activities to comply with the corresponding provisions of this section providing that these activities were conducted in a manner that meets the requirements of this section 49 1910 134 o 0 Appendices o 1 Compliance with Appendix A Appen
58. tor filter or sorbent or other respiratory equipment provides protection to the wearer Supplied air respirator SAR or airline respirator means an atmosphere supplying respirator for which the source of breathing air is not designed to be carried by the user This section means this respiratory protection standard Tight fitting face piece means a respiratory inlet covering that forms a complete seal with the face User seal check means an action conducted by the respirator user to determine if the respirator is properly seated to the face c Respiratory protection program This paragraph requires the employer to develop and implement a written respiratory protection program with required worksite specific procedures 31 and elements for required respirator use The program must be administered by a suitably trained program administrator In addition certain program element may be required for voluntary use to prevent potential hazards associated with the use of the respirator The Small Entity Compliance Guide contains criteria for the selection of a program administrator and a sample program that meets the requirements of this paragraph Copies of the Small Entity Compliance Guide will be available on or about April 8 1998 from the Occupational Safety and Health Administration s Office of Publications Room N 3101 200 Constitution Avenue NW Washington DC 20210 202 219 4667 c 1 In any workplace where respirator
59. y protection program including observations made during fit testing and program evaluation indicates a need for emplovee reevaluation or e 7 iv A change occurs in workplace conditions e g phvsical work effort protective clothing temperature that mav result in a substantial increase in the phvsiological burden placed on an emplovee f Fittesting This paragraph requires that before an emplovee mav be required to use anv respirator with a negative or positive pressure tight fitting face piece the emplovee must be fit tested with the same make model style and size of respirator that will be used This paragraph specifies the kinds of fit tests allowed the procedures for conducting them and how the results of the fit test must be used f 1 The employer shall ensure that employees using a tight fitting face piece respirator pass an appropriate qualitative fit test QLFT or quantitative fit test QNFT as stated in this paragraph f 2 The employer shall ensure that an employee using a tight fitting face piece respirator is fit tested prior to initial use of the respirator whenever a different respirator face piece size style model or make is used and at least annually thereafter f 3 The employer shall conduct an additional fit test wnenever the employee reports or the employer PLHCP supervisor or program administrator makes visual observations of changes in the employee s physical condition t