Save space when mounting servers in long or narrow

image

Contents

1. 6 ZN Introduction ater aan nee id Aap ren 8 232 ENC 8 23 What s Oi cea 8 24 Optional ACCESSOMES certo erahnen 8 1719171011 1611181110 51518101 A lA en 9 3 1 Receiving Unpacking and Removing the Server Side Mount Wall Cabinet from the Box 9 322 Wood studded ACE 3 3 Masonry Wall Surface 3 4 Loading Equipment 3 3 POWER armste 3 61 Protechive GrOUNGING snares tantes ad to a 3 6 1 Connecting the Main Protective Grouding Stud to the Dedicated Branch Ground 10 3 6 2 Connecting the Main Protective Grounding Stud to the Protective Bonding Conductors neren 10 4 Operation LS RS A enen de be nea the eae Aere ete 11 4 1 Operating the DOOL arseen a en 11 4 27 Removing or Installing ADO nan ea ee 11 Removing the Front Panels a tend ink Ria 11 5 Optional Accessories DraWINOS waarvan A neten naren a ee JU 12 RM610A R2 Page 3 Preface Safety Information Preface This manual is provided to prevent service personnel from committing an act that results in the risk of fire electric shock or injury to persons Only trained service personnel should receive unpack and assemble the Server Side Mount Wall Cabinet In addition only trained service personnel should install equipment in enclosures Safety
2. Finish Black powder coat Maximum Rail Depth 29 75 75 6 cm Mounting Holes Designed for 4 hardware Number of Rack Units RUs 10 Rail Type M5 Size 24 H x 36 1 W x 20 5 D 60 1 x 91 7 x 52 1 cm Weight Capacity 250 lb 113 6 kg 36 1 96 1 cm Figure 1 1 Front view Chapter 1 Specifications EC24U3032 724 746 5500 blackbox com Page 5 Chapter 1 Specifications 19 5 49 5 cm Figure 1 2 Right side view 34 86 4 cm 20 5 52 1 cm 36 1 91 6 cm Figure 1 3 Top view Page 6 RM610A R2 724 746 5500 blackbox com Chapter 1 Specifications 16 0 40 6cm DD i 9 4 on E Ho 4 gH 16 0 40 6cm 16 0 40 6cm Figure 1 4 Back view RM610A R2 Page 7 Chapter 2 Overview 2 Overview 2 1 Introduction The Server Side Mount Wall Cabinet is designed for servers and other networking equipment 2 2 Features e Ships with one conduit panel on the bottom and one gland plate on the top e 3 RU cabinet accessories also fit the RU openings top and bottom e Welded steel frame e Includes two pairs of M5 rails e Front door is mesh e Rear door has mounting positions for fans e Side panel and doors are removable for equipment access e Locking doors and side panels 2 3 What s Included
3. Safety Symbols Used in this Manual This manual provides general safety guidelines to be observed during installation operation and maintenance of the Server Side Mount Wall Cabinet WARNING Failure to follow directions in the warning could result in injury to persons or loss of life CAUTION Failure to follow directions in the caution could result in damage to equipment or storage data Safety Considerations WARNING Improper handling and use of the RM610A R2 could result in equipment damage serious injury or possible death Only trained service personnel should be used to remove the enclosure from the pallet Also be sure you have a sufficient number of service personnel Do not attempt to move enclosures by yourself Only UL Listed ITE units should be installed inside the RM610A R2 Be sure to read and follow all individual manufacturer equipment manuals for safety and installation instructions The RM610A R2 was not evaluated as a fire enclosure Proper spacing is required when installing electrical equipment to avoid electrical shock The ambient temperature operating range for the RM610A R2 and accessories is 50 to 95 F 10 to 35 C The non operating temperature is 4 to 140 F 20 to 60 C RM610A R2 Page 4 724 746 5500 blackbox com 1 Specifications Construction Body 14 gauge steel Doors 16 gauge steel Rails 12 gauge steel Door Height 24 60 1 cm Door Width 18 5 46 7 cm
4. Your package should include the following items If anything is missing or damaged please contact Black Box Technical Support at 724 746 5500 or info blackbox com e 1 Server Side Mount Cabinet e 2 sets of keys e 1 gland plate e 1 conduit panel e 20 M5 screws and cage nuts e 16 M5 flat head screws and nuts e 4 fan guards e This user manual 2 4 Optional Accessories e Fan Tray RM4002A e Filter Tray RM4003A e Blanking Panel RM4004A e Fan for rear door RMT373 R2 e 3 RU Conduit Adapter Plate ECP3U e 3 RU Brush Grommet Kit ECBGK3U e 3 RU Waterfall Radius Bracket ECW3U e 3 RU Gland Plate Kit EC3UGP e 3 RU Filler Panel RMTBO3 Page 8 724 746 5500 blackbox com RM610A R2 Chapter 3 Mounting Instructions 3 Mounting Instructions 3 1 Receiving Unpacking and Removing the Server Side Mount Cabinet from the Box Inspect for damage and report damage if there is damage before receiving Refer to Section 2 3 for what s included in the package Unpack the enclosure by carefully removing the corrugated carton and corners Avoid damaging the enclosure when removing packaging WARNING Only trained service personnel should remove the enclosure from the pallet Also be sure you have a sufficient number of service personnel Do not attempt to move enclosures by yourself WARNING Be careful when moving enclosures before installation Sudden stops and starts excessive force obstructed routes
5. dedicated branch circuit 3 6 Protective Grounding A main protective earthing stud and grounding studs are provided WARNING To avoid injury to persons or loss of life ground each enclosure individually to the dedicated branch circuit earthing ground 3 6 1 Connecting Main Protective Grouding Stud to the Dedicated Branch Circuit Earthing Ground Conductor Connect the dedicated branch circuit ground conductor to the main protective earthing stud located inside at the bottom rear of the enclosure chassis using a listed ring or closed loop terminal 3 6 2 Connecting Main Protective Grounding Stud to the Protective Bonding Conductors Connect the rear door to the main protective grounding stud located inside at the bottom rear of the enclosure chassis using a listed ring or closed loop terminal Connect the front door to the grounding stud located inside at the bottom front of the enclosure chassis using a listed ring or closed loop terminal RM610A R2 Page 10 724 746 5500 blackbox com Chapter 4 Operation 4 Operation 4 1 Operating the Door The Server Side Mount Wall Cabinet Enclosure is supplied with two locks one for the front door and one to lock the middle sec tion to the rear section The middle section and rear section incorporate a grabber catch that enables the middle section to be held shut without locking 4 2 Removing or Installing a Door Open the door beyond 90 remove the top half of the upper hinge then grasp
6. the door with both hands and carefully lift it upward When the door is free of two hinge pins pull the door away from the enclosure To attach the door align both door hinges to their respective hinge pins on the enclosure and slowly slide the door down until seated 4 3 Removing the Front Panel To remove the front panel unlock it and then slowly lift it upward RM610A R2 Page 11 Chapter 5 Optional Accessories Drawings 5 Optional Accessories Drawings Figures 5 1 and 5 2 illustrate two of the Server Side Mount Wall Cabinet s optional accessories Use the gland plate kit to close around cables to prevent unwanted airflow and keep dust and debris out Figure 5 1 Optional EC3UGP Gland Plate Kit Use the waterfall bracket to maintain bend radius when routing cables into the cabinet Optional ECW3U waterfall bracket Figure 5 2 Optional ECW3U Waterfall Bracket RM610A R2 Page 12 724 746 5500 blackbox com NOTES RM610A R2 Page 13 NOTES RM610A R2 Page 14 724 746 5500 blackbox com NOTES RM610A R2 Page 15 Black Box Tech Support FREE Live 24 7 Tech support the way it should be Ei UE Great tech support is just 30 seconds away at 724 746 5500 or blackbox com BLACK BOX About Black Box Black Box Network Services is your source for an extensive range of networking and infrastructure products You ll find everything from cabinets and racks and power a
7. RM610A R2 BLACK BOX NETWORK SERVICES Save space when mounting servers in long or narrow rooms Customer Order toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 Support FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Inf ti Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 de Web site www blackbox com E mail info blackbox com Trademarks Used in this Manual Trademarks Used in this Manual Black Box and the Double Diamond logo are registered trademarks of BB Technologies Inc Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners We re here to help If you have any questions about your application or our products contact Black Box Tech Support at 724 746 5500 or go to blackbox com and click on Talk to Black Box You ll be live with one of our technical experts in less than 30 seconds Page 2 724 746 5500 blackbox com nz Table of Contents la E etek en A ed 4 Ei 9 A dias 4 Safety Symbols Used im this Manual asiatica 4 Safety Considerations nn mannenteam Ag nue 4 1 a e a en dt en 5 2 ONT TE A
8. and uneven floor surfaces may cause the enclosure to topple over 3 2 Wood Studded Wall Once the location on the wall has been determined inspect the wall surface The wall must be flat and square in the horizontal and vertical plane to ensure the Server Side Mount Wall Cabinet closes correctly If the wall is not flat and square you might need to use shims You can remove the rear section of the cabinet by removing the hinges Mount the rear section to the wall using the included hardware or install two horizontal bolts in studs DO NOT TIGHTEN using a level Hang the rear section on the two bolts install the lower two bolts line up with a level and tighten Then tighten the upper two bolts WARNING Improper handling and use of the Server Side Mount Wall Cabinet could result in equipment damage serious injury or possible death 3 3 Masonry Wall Surface RM610A R2 Page 9 Chapter 3 Mounting Instructions For a masonry wall surface the installer must provide the appropriate hardware 3 4 Loading Equipment WARNING Only install equipment after the Server Side Mount Wall Cabinet has been properly secured and mounted to the wall Maximum Load Capacity 250 Ib 113 6 kg 3 5 Power When using power distribution units PDUs each PDU should be connected to a committed branch circuit that is rated for the continuous load of all the equipment connected When not using a PDU each piece of equipment should be connected to a
9. nd surge protection products to media converters and Ethernet switches all supported by free live 24 7 Tech support available in 30 seconds or less Copyright 2012 All rights reserved RM610A R2 rev 1 724 746 5500 blackbox com