Home
View PDU User Manual - A
Contents
1. Type of Plug NEMA 5 20P 20A 125V Straight Blade INCLUDED FREE Straight Blade to Twist Lock Jumper Color of Cord Black Cord Location Exits the rear of the housing Switch None Display LCD with backlight Note 20amp plugs DO NOT FIT 15amp outlets 15amp is typical for a residence This power strip WILL NOT work in your residence As product improvement is continuous specifications subject to change and without notice LCD DISPLAY METER FUNCTION METER FUNCTION 8 FUNCTIONS PROVIDED Plug in the power strip and it starts to display current power supply status e Voltage Amp A Watt VA e Hz PF e Kwh e Runtime Clock No start button required FUNCTION and SET buttons are located on the right side of the LCD Display O manis AMP A JANGULONICS OPERATION Plug in the strip the display shows voltage reading Press FNC button shows amperage reading Press FNC button again shows watt reading Press FNC button again shows VA apparent power reading C mamanis Press FNC button again shows Hz frequency reading Press FNC button again shows PF power factor reading Press FNC button again shows KWH kilo watt per hour reading O mamis Press FNC again shows runtime clock O mamis OVER VOLTAGE AND OVER CURRENT WARNING 1 LCD display will show OUP when input voltage
2. is over 145V 2 LCD display will blink when input current is over 20A RE SET KWH AND CLOCK Power cycle unit by turning OFF and then ON again This will reset the KWH and clock SET OVER CURRENT WARNING LEVEL This power strip is designed to operate at 20Amps Changing this Over Current Warning Level value does not allow more then the specified amperage as specified on the product label 1 Press SET button for 3 seconds FUNCTION RANGE ACCURACY 2 Press FUN button so display is either 15A or 30A 3 Press SET button to select the new setting 4 Press FUN button to return to normal operation LIMITED WARRANTY This Warranty is given ONLY to purchasers who buy for commercial or industrial use in the ordinary course of each purchaser s business General A Neutronics Inc products are in our opinion the finest available We take pride in our products and are pleased that you have chosen them Under certain circumstances we offer with our products the following three 3 year Warranty against Defects in Material and Workmanship Please read your Warranty carefully This Warranty sets forth our responsibilities in the unlikely event of defect and tells you how to obtain performance under this Warranty TWO YEAR LIMITED WARRANTY AGAINST DEFECTS IN MATERIAL AND WORKMANSHIP A NEUTRONICS INC PRODUCTS COVERED ANI 17015ASUR Series Terms of Warranty As provided herein the A Neutronics Inc product
3. NP 26024 24 0utlet LCD Display Vertical Power Strip 20Amp INSTRUCTION MANUAL A Neutronics 122 Rose Ln Suite 303 Frisco Texas 75034 TOLL FREE 1 877 ANEUTRON TOLL 469 362 9228 Email sales a neutronics com A Neutronics com 10 11 12 13 14 15 16 17 18 19 SAFETY INFORMATION To ensure the best results from this product please read this manual and all other documentation before operating your equipment Retain all documentation for future reference Follow all instructions printed on unit chassis for proper operation To reduce the risk of fire do not spill water or other liquids into or on the unit or operate the unit while standing in liquid Make sure power outlets conform to the power requirements listed on the back of the unit Keep unit protected from rain water and excessive moisture Do not attempt to clean the unit with chemical solvents or aerosol cleaners as this may damage the unit Dust with a clean dry cloth Do not use the unit if the electrical power cord is frayed or broken The power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords and plugs convenience receptacles and the point where they exit from the appliance Do not force switched or external connections in any way They should all connect easily without needing to be forced Always operate the u
4. alternate waveform UPS or generator power in rack enclosures network closets and more Includes 15 foot AC power cord 20 amp circuit breaker and a 2 Year Warranty There is a lighted LCD Volt Meter to let technicians know exactly how much power is being drawn before they plug in additional equipment SAFETY PRECAUTIONS Please read all instructions before attempting to unpack install or operate this equipment and before connecting the power supply Please keep the following in mind as you unpack and install this equipment Always follow basic safety precautions to reduce the risk of fire electrical shock and injury to persons To prevent fire or shock hazard do not expose the unit to rain moisture or install this product near water lt Never spill liquid of any kind on or into this product e Never push an object of any kind into this product through any openings or empty slots in the unit as you may damage parts inside the unit Do not attach the power supply cabling to building surfaces Use only the supplied power supply unit PSU Do not use the PSU if it is damaged Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it To protect the unit from overheating do not block any vents or openings in the unit housing that provide ventilation and allow for sufficient space for air to circulate around the unit DISCLAIMERS The information in t
5. his manual has been carefully checked and is believed to be accurate We assume no responsibility for any infringements of patents or other rights of third parties which may result from its use We assume no responsibility for any inaccuracies that may be contained in this document We make no commitment to update or to keep current the information contained in this document We reserve the right to make improvements to this document and or product at any time and without notice COPYRIGHT NOTICE No part of this document may be reproduced transmitted transcribed stored a retrieval system or any ofits part translated into any language or computer file in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without express written permission and consent Copyright 2015 All Rights Reserved Version 1 2 JAN 2015 TRADEMARK ACKNOWLEDGMENTS All products or service names mentioned in this document may be trademarks of the companies with which they are associated SPECIFICATIONS SPECIFICATIONS Overall Length 19 inch with rack mount Number of Receptacles 24 Cord Length 15ft Mounting Type 3 Flange Removable rack mounting screws not provided Approval UL Approved Maximum Rating 60Hz 20A 120V Housing Brushed Aluminum Dimentions HxWxD 60 5 x 1 75 x 2 in Type of Receptacle 5 20R 20A 125V Black Outlet Circuit Breaker 20 amp Cord Type 12 3 SJT
6. is warranted to be free of defects in material and workmanship for a period of three 3 years from the date of delivery of the product to User The delivery date will be determined only from the A Neutronics Inc bill of lading If any of the A Neutronics Inc products fails to conform to the warranty within the warranty period A Neutronics Inc at its option will furnish new or factory remanufactured parts for repair or replacement of that part Warranty Extends to First Purchaser for Use Non transferable This Warranty is extended to the first person firm association or corporation for whom the A Neutronics Inc product specified herein is originally installed for use the United States the This Warranty is not transferable or assignable without the prior written permission of A Neutronics Inc Assignment of Warranties A Neutronics Inc assigns to User any warranties which are made by manufacturers and suppliers of components of the A Neutronics Inc product and which are assignable but A Neutronics Inc makes NO REPRESENTATIONS as to the effectiveness or extent of such warranties assumes NO RESPONSIBILITY for any matters which may be warranted by such manufacturers or suppliers and extends no coverage under this warranty to such components Descriptions A Neutronics Inc warrants for the period and on the terms of the Warranty set forth herein that the A Neutronics Inc product will conform to the descriptio
7. nit with the AC ground wire connected to the electrical system ground Precautions should be taken so that the means of grounding of a piece of equipment is not defeated AC voltage must be correct and the same as that printed on the rear of the unit Damage caused by connection to improper AC voltage is not covered by any warranty Turn power off and disconnect unit from AC current before making connections Never hold a power switch in the ON position This unit should be installed in a cool dry place away from sources of excessive heat vibration dust moisture and cold Do not use the unit near stoves heat registers radiators or other heat producing devices Do not block fan intake or exhaust ports Do not operate equipment on a surface or in an environment which may impede the normal flow of air around the unit such as a bed rug carpet or completely enclosed rack If the unit is used in an extremely dusty or smoky environment the unit should be periodically blown free of foreign dust and matter To reduce the risk of electric shock do not remove the cover There are no user serviceable parts inside Refer all servicing to qualified service personnel There are no user serviceable parts inside When moving the unit disconnect input ports first then remove the power cable finally disconnect the interconnecting cables to other devices Do not drive the inputs with a signal level greater than that required to drive equi
8. ns contained in A Neutronics Inc final invoices orders and A Neutronics Inc product brochures A Neutronics Inc does not control the installation and use of any A Neutronics Inc product Accordingly it is understood that the Descriptions are NOT WARRANTIES OF PERFORMANCE and NOT WARRANTIES OF FITNESS FORAPARTICULAR PURPOSE Obtaining Performance under This Warranty Within a reasonable time but in no case to exceed thirty 30 days after User s discovery of a defect User shall contact A Neutronics Inc and request a return authorization number User shall ship the product with proof of purchase to A Neutronics Inc freight prepaid A Neutronics Inc products shipped to A Neutronics Inc without a return authorization number will be refused and returned freight collect to User at User s expense A Neutronics Inc products shipped by User to A Neutronics Inc which have incurred freight damage due to User s improper packaging of the product will not be covered by this Warranty and any repairs or replacement parts components or products needed will be invoiced in the full current price amount and returned freight collect to User Subject to the limitations specified herein A Neutronics Inc will repair or replace at its option without charge for A Neutronics Inc labor or materials subsequent to its inspection and A Neutronics Inc facility the A Neutronics Inc product shipped to A Neutronics Inc with a return au
9. pment to full output The equipment power cord should be unplugged from the outlet when left unused for a long period of time Save the carton and packing material even if the equipment has arrived in good condition Should you ever need to ship the unit use only the original factory packing Service Information Equipment should be serviced by qualifier service personnel when A The power supply cord or the plug has been damaged B Objects have fallen or liquid has been spilled into the equipment C The equipment has been exposed to rain D The equipment does not appear to operate normally or exhibits a marked change in performance E The equipment has been dropped or the enclosure damaged THIS SAFETY INFORMATION IS OF A GENERAL NATURE AND MAY BE SUPERSEDED BY INSTRUCTIONS CONTAINED WITHIN THIS MANUAL TABLE OF CONTENTS CONTENTS INTRODUCTION SPECIFICATIONS LCD DISPLAY METER FUNCTION INTRODUCTION A Neutronics Inc NP 26024 AC power distribution unit offers 20 amp 120 volt capacity in a single rack mount cabinet The built in power meter has 8 different displays showing Volt Amps Watt VA Frequency Power Factor Kilowatts and KW per hour Offers horizontal or vertical power distribution in rack mount raceway or workbench applications Sturdy all metal extruded aluminum housing stands up to demanding network laboratory or factory environments Unfiltered electrical pass through and lighted switch Ideal for distributing
10. thorization number and warranted hereunder which does not conform to the Warranty Replacement parts components or products shipped to User prior to A Neutronics END OF DOCUMENT L O