Home
Operating Instructions
Contents
1. Hit two grounding rods deeply into the ground at a humid place directly nearby your fence having a distance of 3 feet to each other Connect the two grounding rods with an appropriate earthing cable and connect them also to the ground connector of the energizer For connections always use corrosion resistant grounding cable Note that the most performance and output power of your energizer can only be achieved by best grounding and fence isolation conditions Connect your fence and the fence connector of your energizer using the red fencing cable Connect the energizer to the 12V battery in the right connection order of the battery clamps red clamp black clamp Now the green battery control LED in the energizer should light constantly and the energizer should start working Using the battery deep discharging protection The energizer GA4500 protects the battery with an in built deep discharging protection If the battery voltage sinks below 10 8V the deep discharging protection turns off the energizer and the green battery control LED blinks Please note O 12V lead acid batteries must be charged approx every 6 months even when they are not in use O Ifthe green battery control LED does not light constantly after connecting the energizer to the battery probably the battery is not charged well or the battery is not suitable for the energizer O When the green battery control LED starts flashing during normal operation of the energizer t
2. The energizer GA4500 is also fitted with an in built power saving circuitry connected to a good fence without faults and without arc overs and to a good grounding the power consumption is being reduced to a minimum The more impulse energy is transferred into ground by bad fence isolation animals touching or fouling more power is taken out of the battery by the energizer Below is shown how long a battery could operate the energizer depending on the fence conditions capacity min operating time max operating time 36Ah 3 days 20 days 44Ah 4 days 28 days 88Ah 7 days 50 days
3. Warranty Card Terms of Warranty User manual english version C To your energizer Granit GA4500 Battery Energizer GA4500 we issue warranty for a period of Best Nr 580580106 3 years at following conditions We issue warranty to your energizer GA4500 for a period of 3 years from date of selling at following conditions The selling date has to be proved by this certificate of guarantee which has to be accurately completed by your dealer All deficiencies or damages during this period that can be traced back to faults of material or faults of fabrication will be repaired costless when the device is returned to us prepaid This warranty cannot be issued when the device is being connected to wrong power supply or when it was damaged due to an Act of God e g lightning stroke or water damage It also cannot be issued in any case of unauthorized intervention or maloperation Device Battery Energizer Granit GA4500 Selling date Serial number Packing unit 1 battery energizer GA4500 1 set fence and grounding cable 1 warning plate i f dealer Bedlerstamnipisignatureordcale 1 user manual and warranty card p65 To execute repair works please contact your local GRANIT dealer GRANIT QUALITY PARTS GRANIT QUALITY PARTS 86283C_BAL_GA4500_Granit_ENGLISCH Mounting Mount the energizer Granit GA4500 upright at a wooden rod at a wall or in an appropriate housing or case Protect the energizer from water
4. he battery has to be charged Keep the battery terminals clean and grease them lightly with battery grease The most performance and output power of your energizer is achieved by proper grounding conditions Connectors fence control and energizer control The energizer GA4500 has two fence connectors O Fence connector 1 strong puts out maximum impulse energy It is used for long fences and non sensitive animals O Fence connector 2 reduced power output puts out half the impulse energy of fence connector 1 It is used for shorter fences and sensitive animals O Both fence connector 1 and 2 can be used at the same time and independant to each other Note that if one fence connector is shorted to ground then this can affect the power output of the other fence connector in negative way O O The energizer GA4500 has both an integrated fence control and an energizer control O The red energizer control LED flashes shortly with each energy impulse and shows correct working of the energizer and good fence isolation If the energy driven into the fence is being transferred into ground e g by animal touching or by plants touching the fence or by fouling the red energizer control LED is lit for a longer period while flashing O The fence control bar indicates the voltage at the fence connector 1 by each fence impulse If the control bar flashes completely green then voltage at fence connector 1 is above 5000 volts The last yellow bar fla
5. shes at approx 4000V and when the voltage sinks below 2000 volts then no bar will flash In this case you will not be able to herd animals any more due to the low output voltage of the electric fence If you notice changes in the amplitude of the fence control bar then changes in the fencing conditions or bad isolators could be a reason Ground test connector O The ground test connector is designed to control the grounding conditions permanently Use a separate groundig rod hit it into the ground separated 3 to 6 feet away from the normal grounding rods When the yellow grounding control LED flashes then grounding conditions are normally suitable Safety informations Not following the safety instructions and an incorrect energizer setup could lead to hazard and may cause technical malfunction of the energizer Please observe strictly following items O Connect your energizer GA4500 only to a 12V battery O Always use proper fencing material when using flexible fencing wire Wire of low quality is not recommended O Your energizer GA4500 cannot be used for herding sensitive animals O Build up your fence solidly Avoid your animals from getting tangled in your electric fence Check the condition of your fence and your energizer daily O Check the condition of your 12V battery daily and charge it if required Avoid deep discharging Consider that a 12V lead acid battery discharges slowly by itself even if it is not used Power saving
Download Pdf Manuals
Related Search
Related Contents
USER MANUAL & INSTALLATION INSTRUCTIONS HYXION 36 Bravetti XSP21HCU User's Manual Series MP Bedienungsanleitung Beutel-Bodenstaubsauger allegato_119. - Comune di Trescore Cremasco LT-4203 Parallel Plate Test Cell Specifications Receptor de Tipo Pared FOSTER GASTRO ECO PRO 2011 FD2-10 Copyright © All rights reserved.