1.     Weight   3 Kg     6 8lbs      CE    The product is in compliance with Directive 89 336 EEC  Electromagnetic Compatibility   and following modifications 92 31 EEC and 93 68 EEC  as the following standards   EN 50082 1 1997  EN 55013 1990  EN 55020 1994    it is also in compliance with Directive 73 23 EEC  Low Voltage   and following modifications 93 68 EEC  as the following standard   EN 60065 1998       PROEL    PROEL S p A     World Headguarters   Factory   Via alla Ruenia 37 43  64027 Sant   Omero  Te      Italy  Tel   39 0861 811241  Fax   39 0861 887862    E mail  info proelgroup com    installation proelgroup com    
2. Grounding is useful for user   safety   Use only connectors and accessories suggested by the manufacturer     This unit should be placed in a rack  see INSTALLATION  and kept far from     gt  Wet places    gt  Direct exposure to heat sources  like sun light     gt  Non properly ventilated places  Disconnect the power cord during storms or when the unit is not used     A In order to prevent fire and electric shock risks  it s necessary to keep the unit far  from sprinkling and drops  Please don   t put cups  vases or other object containing liquids  over the unit  In case of interferences from source signal  THD value will raise over 10    Don t place this unit in a bookshelf o in other places with small room    PROEL S P A  is not responsible for any damage that occurs due to a wrong unit  installation     Thank you for choosing one of Proel products  and for your confidence towards  our brand  synonymous of professionalism  accuracy  high quality and reliability   All our products are CE approved and designed for continuous use in  professional installation systems     Description    This unit has been specifically designed to eliminate feedback that may  incur in a PA system     FEATURES    Advanced design and manufacturing accuracy  Very easy installation   Four independent NOTCH filters   Frequency cut controls   Frequency level LED indicator   Filter bypass master switch   24V DC emergency power    Front panel description       POWER switch and LED  Freguency level LED i
3. USER S MANUAL    FEEDBACK SUPPRESSOR       AF4       PROEL    DD    1  IMPORTANT SAFETY INSTRUCTIONS    CAUTION       RISK OF ELECTRIC SHOCK j  DO NOT OPEN    CAUTION  To reduce the risk of electric shock do not remove cover  or back panel   No  user serviceable parts inside  Refer servicing to qualified personnel only     WARNING  To reduce the risk of fire or electric shock  do not expose this apparatus to  rain or moisture     This symbol is intended to alert the user of the presence of uninsulated  dangerous voltage within the product enclosure that may be of sufficient  magnitude to constitute a risk of electric shock to persons     A This symbol is intended to alert the user of the presence of important operating  and maintenance  servicing  instruction in the literature accompanying the  appliance  Please carefully read the owner s manual     INSTRUCTIONS     All safety and operating instructions should be read before the product is operated     Retain these instructions    All safety and operating instructions should be retained for future reference    This owner s manual should be considered as a part of the product and it must accompany it  every time  and delivered to the new user when this product is sold  In this way the new owner will  be aware of all the installations  operating and safety instructions     Heed all warnings     All warnings on the product and in owner s manual should be adhered to   Heed all warnings     Follow all instructions   All operating 
4. and user s instructions must be followed     UI    Sentences preceded by A symbol contain important safety instruction  Please read it carefully     DETAILED SAFETY INSTRUCTIONS     Water and moisture   This apparatus should not be used near water  i e  bathtub  kitchen sink  swimming pools   etc      Ventilation   This apparatus should be placed in position that doesn t interfere with correct ventilation  This  unit  for example  should not be placed on a bed  sofa cover o similar surfaces that could  cover ventilation openings  or placed in a built in installation  such a bookcase or a cabinet  that could block air flow trough ventilation openings     Heat   This apparatus should be placed away from heat sources  like radiators  heat registers  stoves  or other products  including amplifiers  that produce heat     Power sources      This apparatus should be connected only to power source type specified in this owner s  manual or on the unit   e If the supplied AC power cable plug is different from wall socket  please contact an  electrician to change the AC power plug     Grounding or Polarization   e All precautions must be observed in order to avoid grounding or polarization defeating   e Unit metal parts are grounded through the AC power cord      If the AC power outlet doesn t have grounding  consult an electrician for outlet grounding     Power cord protection   The power cord should be routed in a way it will not be walked on or pinched by items placed  upon or agains
5. n order to choose the desired frequency  60Hz   6KHz  use  FREQ knob in conjunction with its multiplication switch  x1  x10   You  can set each frequency attenuation using the DEPTH knob     UI    6  Filter bypass master switch  In case you desire to deactivate or to control unit filters operation  it s  possible to simultaneously deactivate all the filters pressing the switch   fig 1 ref 3  to its OUT position  To make filters active again press again  the switch  IN     Operations    a  Toturn on the unit press the POWER switch ON  its led is lit    b  Toturn offthe unit press the POWER switch OFF  its led too will be off  as well    c  In order to do an accurate frequency setting  please use the unit front  panel freguency level LED indicator    d  To activate de activate all NOTCH filters use the IN OUT switch  fig 1  ref 3     e  In order to modify attenuation frequency  please use FREQ knob and  x1 x10 switch  the choose the attenuation use DEPTH knob  fig 1 ref 4      A Warning  In order to avoid forthcoming units damage  please before  connecting any sound source to this unit  control that its volume is totally  lowered     Technical Specifications    Model AF4    Input connector Balanced 6 3mm  1 4     jack   Output connector Balanced 6 3mm  1 4     jack  Freguency response 20Hz 20KHz  gt   1dB          Power requirements AC 110 120   220 230V     50 60Hz  DC 24V    Rack dimension   1U 19    standard    Dimensions WxHxD 483x44x210  mm       19in  x 1 75in  x 8 2 in  
6. ndicator   Filter bypass master switch   Freguency and filter attenuation settings    poe Md    Rear panel description          E          IEC standard AC power supply socket  Fuse holder   24V DC emergency power supply terminals  Balanced 6 3mm  1 4     output jack connector  Balanced 6 3mm  1 4     input jack connector    MAN    UI    Installation    1     AC power supply connection   To connect this unit to AC power supply please use supplied linecord     Input connection   The input connector  fig 2 ref 5  is a balanced 6 3mm  1 4     jack  connector  This connector accepts line level sound sources  like tuner   CD player  tape recorder  etc  Please refer to following picture for  wiring     BALANCED    TIP    RING  xD SLEEVE    Output connection   The output connector  fig 2 ref 4  is a balanced 6 3mm  1 4     jack  connector  This connector may be used to connect other units  like  sound processors or amplifiers     Emergency power   By using the rear panel terminals  fig 2 ref 3  this unit can be connected  to 24V DC power supply  allowing use during black out  DC power  supply can be supplied by an external generator or a battery  24V  able  to supply 0 5 A at least     Frequency level LED indicator   Using this display  fig 1 rif 2  it s possible to check the signal behaviour   In this way its easier to control feedback or noises generating  frequencies     Filters adjustment controls   The unit has four filters  for each filter there are two knobs and one  switch  I
7. ration could result in fire or electric shock     Damages requiring services      Don t attempt to do operations not described in this user s manual   e In the following cases please refer to an authorized maintenance center or skilled  personnel      When the unit works improperly or it doesn t work at all     If power cord or plug are damaged     If liquid has spilled  or objects have fallen into the unit     The unit has been exposed to rain     The unit doesn t operate normally o it exhibits a marked change in performance     If the product has dropped or it has been damaged in any way     Maintenance   The user shouldn t attempt maintenance operation not described in this user s manual  Every  maintenance operation should be done by gualified personnel only     IMPORTANT SAFETY INSTRUCTIONS       Install this unit following owner s manual instructions    e Don t install  connect or disconnect power supply when the unit is powered  otherwise  there   s an high risk of electric shock    e Don t open the unit  there are no user serviceable parts inside    e If you detect a particular smell from the unit  please turn it off immediately and disconnect  the AC power cord       Don t block the unit ventilation openings    e Avoid using this unit in overload for a long period       Don t force commands  switches  controls  etc      UI    To obtain good speakers wire contacts  please tighten the screw terminals firmly     For safety reason  don t defeat the grounding connection  
8. t it  paying particular attention to cords at plugs  convenience receptacles and  wall outlet     Cleaning   e You can clean the unit with a compressed air flow or a wet cloth      Don t clean the unit using solvents like trichloroethylene  thinners  alcohol  or other fluids  with very strong volatility and flammability     Non use periods   The unit AC power cord should be unplugged from the outlet if it s unused for a long period     Objects or liguid entry inside the unit   Be careful that no objects fall or liguid is spilled inside the unit through ventilation openings     Safe power line use    e Keep firmly the plug and the wall outlet while disconnecting the unit from AC power       If you re not going to use the unit for a long period of time  please unplug the power cord  from AC power outlet       To avoid unit power cord damaging  please don t strain the AC power cable and don t  bundle it    e In order to avoid unit power cord damaging  please be sure that the power cord is not  walked on or pinched by heavy objects     Unit relocation   Before any unit relocation please control the unit is turned off  The power cord must be  unplugged by the wall outlet  and all the connections wires should be disconnected as well     Don   t open this unit   Don t attempt to open or to repair this unit by yourself  For any problem solution not described  in this owner s manual  please refer to qualified personnel only or consult us or your National  Distributor  Any improper ope
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Leírás  OPERATION MANUAL Walk behind power trowels Type  取扱説明書のダウンロード  fiche-inscription-mode-emploi - Club d`Activités Subaquatiques  暮らし・彩り・公民館 [PDFファイル/673KB]  RL78 Family EEPROM Emulation Library Pack02 Ver.1.01 for the  Samsung 473 л. холодильник с верхней мороз. камерой RT59FBPN Инструкция по использованию    Copyright © All rights reserved. 