Home
C&K Systems 238 Keypad User Manual
Contents
1. PartNumber5 051 372 00 Rev B Using your LED Plus keypad _ System 238 L System 238i C System 2316 System 2316i GK SYSTEMS Congratulations Thankyou forpurchasing thisC amp Ka la m system Yoursystem isone ofthe mostpowertul and advanced alarmsystemsonthe markettoday designed to provide you with yea rsof relia ble operation Thisma nualexplainshow to operate youra la m system Basic operating instruc tionsare also printed onthe smalllabelattac hed to the insde of yourkeypad s door Ifyou have questionsorneed help with your Ifyou have monitoring questionsorin cases alarmsystem call ofaccidentalalarms call AlamCompanyName Monitoring tationName gt QR Whencalling the monitoring company know the following MyAccountNumberis My Pa sword is 2 Table of contents Getting aCquainted ee eeeeeeeeeeeeeeeeeeeeeees 4 5 Whatthe lightsmean eeeeeeeeeeeeeeeeteeeeees 6 7 Whatthe SOUNCSMEAN 1 eeeeeeeeeeeeeetteeteeeeees 8 Aming the SYSOM ce ceeceeeete ects ceeeeteeeteeeteeeeeees 9 15 BYPASSING ZONES ee seceeeeeeeeeeteteetteeteeeeeee 14 15 AMMing OPtiONS crion eraras iarsan 16 17 Disa ming the system ssssesssssissessrsrerrsrrsrnrrseees 18 Afteranala MN enoe 19 ODDO MS uan eee e teas 20 31 Guegcombination sssssessssesreissrsrrerrrrenes 23 Changing a userPIN System 238 23
2. expires the GUESTC OMBINATION willhave to be reprogrammed before itcanbe used again RING BACK AFTER CLOSING Whenthisoption isinsta lled the bell siren willsound fortwo secondsafter the systemisarmed fyoursystem isprogrammed to send closing reportsto a monitoring station ring back occursafterthe sgnalissentand acknowledged otherise ring backoccurswhenthe exitdelayexpires 23 Options CHANGING A SYSTEM 238 AND 238i USER PIN User1 can use hisMaster PIN to change the PINsof Users 1 8 MASTER PIN W _ Enter your Master PIN push the rege key enter the digit 0 then ed push the key KE EA The READY ARMED and SERVICE lights will flashdowlyto indicate programming mode a Tii he awai ad pish JAAA The new PIN can be from two to five digits long butmuststartwith the same first digit as the old PIN 33 Enter the new PIN again and Ly Ly LJLJL push the key Ifthe new PIN isaccepted the keypad willbeep twice Ifyou make a misa ke while programming orifthe system rejectsthe new PIN the keypad willbeep five times 24 Options Exit the programming mode by pushing the EJ l A key then the key 5 Make sure the new PIN works Afterleaving the programming mode Amand Disarmyoursystemto ensure thatthe new PIN functionspropeny 25 Options MASTER PIN REQUIRED DELETING A USER PIN SYSTEM 238 AND 238i User 1 can use hisMasterPIN to dele
3. 8i 24 25 Deleting a userPIN System 238 238i 26 Changing a userPIN System 2316 2316 27 28 Deleting a userPIN System 2316 2316 29 Resetting smoke detectors sssr 30 DOONG HIME risorge inin ani 31 Standby battery sssini iniinda 31 Testing yoursystem o eeeeeeeseeeeeeeeeeteeetteeeneeeaees 32 34 Telephone trouble ssssssssessesirssrrssrrrrssrerrsrnssnn 35 Smoke detectormlaceMent ccssceesessreeeees 36 Emermgencyevacuation cecceeeeeeeeeeteeetereeeees 37 DEFINO NS disiri E Ta 38 Limitationsofyoura la MyStem sesser 39 Tegprocedu eindeX ssssesssesssssrrsresrrrersrnssns 40 Zone descrptionlis oo eee eee eee ette ete teeeteeeeeees 41 42 FCC Industry Canada yiii 43 44 Getting acquainted What your alam system is Youralarmsystemismade up ofa controlpaneland severaldetection deviceslike motion sensors magnetic contacts and soon Specific areasofdetectionare called zones Znescanbe programmed to have differentcharacteristics Some zonesmay be 24 hourzones thatis they re ma in a med even when the alarmsystem isoff Zonesused forfire detection forexample are always24 hourzones Inaddition some zonescanbe programmed to allow bypassing Whenyoubypassa zone you temporarilyremove itfrom the alarm system Alwaysremember however thatbypassed zonesare notprotected How your alam system works Whena detection device istriggered the statusofitszone goesfrom nomalto FAULTED Ifarmed th
4. LURE off ondeady Powerfail Systtemon battery SYSTEM IS READY ALL ZONES NORMAL onsteady Readytoam FAULTED ZONE WHILE DISARMED off ondeady Oneormorezonesare faulted SYSTEM IS ARMED F ALL PROTECTION ON off onsteady Readylightwillbe on untilsysem isa med SYSTEM IS DISARMED ee eee ALL PROTECTION OFF on Readylightison ifallzonesa re nomal SYSTEM IS ARMED WITH DELAY ZONES off slow flash Amed with 7 CONVERTED TO INSIANT PERIMETER ARMED dowflash onsteady dow flash Amed with 4 WITH DELAYS INTACT Fla shing zonesare bypassed 6 What the lights mean POWER READY ARMED SERVICE ZONES REMARKS LIGHT LIGHT UGHT LIGHT LIGHTS Oa Bey Sone slowflash dowflash slowflash_ Armed with 47 Fla shing zonesare bypassed CONVERTED TO INSTANT slowflash slowflash Service and zone introuble ZONE TROUBLE Flashatthe same rate ZONE S IS OR slow flash on fastflash Analarmhasoccuned onthiszone WAS IN ALARM Armmed lightison ifthe system isarmed ZONE BYPASSED dow flash slow flash Readyand bypassed zone flashatthe samerate LOW BATTERY slow flash ongeady Callforservice BELL FUSE FAILURE ongeady Callforservice WATCHDOG RESET slow flash Panelhasresetitself Sytem OK To resetthe Service Light press 1 Sq a fastflash Callforservice fone dow flash dow flash slow flash Systemisin programming mode What the sounds mean SOUND MEANING 2beeps
5. VE TELEPHONE TROUBLE First unplug the control panelfromitstelephone jackto determine ifthe alarmsystem isc ausing the trouble The phone jac kislocated Ifthe trouble goesawaywhen you unplug the control callusforservice lIfyoustillhave telephone trouble afterunplugging the alarmsystem plug the system backin thencall yourtelephone company NOTE If yourtelephone system isservic ed make sure to test youra la m system to insure thatithasnotbeendisc onnected fromthe telephone network 35
6. Y BATTERY Should there be a lossofAC power the green POWERIlightonthe keypad willgo out and youra lam system willswitc h to itsstandby battery Ifan AC powerfailure lastsformore than 15 minutes the yellow SERVIC Elighton the keypad willcomeon The standby battery should be replaced every fourto six yearswith a rechargeable 12 volt 6 5Ah sealed lead acid battery suchasC amp KModel1265 31 Testing gour system LOCAL SYSTEM TEST Thisoption allowson site testing of each zone in yoursystem To initiate the LOCAL SYSTEM TEST m lt Enter your PIN if required ae ee ee ee po push the gt key enter the digit 6 the digit 0 then push the key ae Oncethe keypad lightsgo out the sytem Leu KE EA willbe readyfortesting Walkthrough the areasprotected bymotionsensors openand close protected doorsand windows Each time a zone isfaulted itsc omesponding red ZO NElightonthe keypad willbegin flashing and the keypad willchime To exit the system test push any key lt gt WARNING Your alam system will not report alarms during the LOCAL SYSTEM TEST 32 Testing your system OPTION INSTALLED OPTION INSTALLED PIN REQUIRED STANDBY BATERY TEST Youralarmsytemcanbe programmed to automaticallytestitssttandby battery every 24hours During the test AC poweristumed offin orderto monitorthe batteryunderload To manually test the sta
7. aving the programming mode Amand Disarmyoursystemto ensure thatthe new PIN functionspropeny 28 Options MASTER PIN REQUIRED DELETING A USER PIN SYSIEM 2316 AND 2316i User 1 can use his Ma ster PIN to delete the PINs of Users 2 32 See Note pg 27 Enter your Master PIN push the Le LH j key enter the digit 0 then push the key LON LEN The READY ARMED and SERVICE lights will flashdowlyto indicate programming mode Enter the User number and push the key 2 ee lt 3 Enter zero and push the key KE EA l Enterzero again and push the key Loyley Exitthe programming mode by pushing the ES key then the key 29 Options on RESETTING SMOKE DETECTORS OPTI INSTALLED Whena smoke detec toristriggered the red ZO NElightofthe zone where it s located willcome on and the bell sren willsound Before you do anything else evacuate the building Don tgo back inside until you re sure its safe When it ssafe to do so youcanresetthe smoke detec torsby doing the following Push the key enter the digit 6 Lou LZE LEN the digit 2 and push the key 30 Options OPTION INSTALLED OPTION INSTALLED DOOR CHIME When thisoption isinstalled the keypad willbeep fortwo sec ondseachtime a designated zone isfaulted To tumthe DoorChime onand off Push the key enter the digit 5 EJ E Tl EJ then push the key STANDB
8. e controlpanelrespondsbyreporting analarmcondition onste flashing keypad lights sounding bells and ifprogrammed bytransmitting an alam signaloverthe telephone wiresto a central monitoring station The monitoring stationthen dispatc hesthe appropriate authonties Some ofyoursystem soperationsrequire youto enteryourpersonalidentificationnumber PIN onthe keypad These include ARMING and DISARMING Along with itsmany otherfeatures yoursystem canbe programmed to ARM INSTANTLY orto ARM WITH TIME DELAY i e aftergiving you time to leave the premises Getting acquainted Each alam sygem in the 2300fa mily isdesigned to meetthe specific needsofa varietyofapplications Sytems 238and 2316are designed forapplic ationsrequiring protectionofeightand sxteenzones respectively Some ofthe availa ble featuresofyouralarmsystemare also optional and willonlybe installed ifappropriate for yourinsta llation In addition some system feature swill require youto enteryourpersonalidentification number PIN Asyouread through thisma nual watch forboxeslike these INSTALLED REQUIRED Ifanoptionalfeature hasbeen installed in yoursystem its WY OPTION INSTALLED box will be checked Ifa feature ofyoursystem requiresyou to enteryourpersonal identific ation number itsPIN REQUIRED boxwillbe checked What the lights mean POWER READY ARMED SERVICE ZONES REMARKS LIGHT UGHT LUGHT LIGHT LIGHTS AC FAI
9. fan alam Bypassing interiorzoneswillallow you to move aboutfreely inside the premiseswhile the system isarmed Referto BYPASSING ZONES on page 14 11 Maming the system HOME ARMING Home Aming armsperimeterzones while bypassing interiorzones except 24 hourzones Make sure the green READY light is on m 2 Enter your PIN if required Ll Ll Lol Cll ir push the key enter the digit 4 then push the key The keypad willbeep twice to confimthatthe system isarmed Home Aming allowsyouto move aboutfreely insde the premiseswhile the system is amed When the system isHome Amed you canenterthe premiseswithoutsetting offan alamthrougha delayed entryzone Don tforgetto disa mthe systema fterentry 12 Aaming the system INSTANT HOME ARMING Instant Home Aming armsperimeterzones and bypassesintenorzones exc ept24 hourzones Entry time delaysare converted to INSTANT 7 Make sure the green READY light is on pn Enter your PIN if required LH Ly Lal Lali push the key enter the digit 7 E the digit 4 then push the key ay Ge The keypad willbeep twice to confirm thatthe system OR abel EE EA The red ARM light willflash while the perimeterzones areinstantamed ep CAUTION Whenthe systemisinstant Home Amed youwillnotbe able to enter throughanypenmeterdoorwithoutsetting offanalam 13 Heaming the system BYPASSING ZONES T
10. fterthe fifth beep enteryourPINnumberagain forming the system Q Make sure the red ARM light comes on The keypad willbeep twice to confirm thatthe system isamed Exit through any TIME DELAY DOOR within___ seconds The exitdelaytime canbe programmed from 10secondsto 150seconds ornon __ If the EXITPRE ALARM option isinstalled the keypad willbeep slowly until 10 seconds INSTALLED before the delaytime expires then ra pidlyforthe lat 10seconds Once the exitdelaytime hasexpired the keypad willbeep twice to confimthatthe systtemisarmed The restof the ARMING THE SYSTEM section explainshow to bypasszonesbefore aming the system aswellascertainaming optionsourinstallerc an install However it simportant foryouto ememberthatno matterhow yoursystem isprogrammed youwillalwaysdisarm it in the same way enter your PIN then push the key 10 Htaming the system INSTANT ARMING InstantArming convertsalltime delayed zonestoINSTANTZzones Make sure the green READY light is on m 2 Enter your PIN if required Ll Li U j perce push the key enter the digit 7 then push the key The keypad willbeep twice to confirm thatthe system isarmed LJ The red ARM lightwillfla sh while the system isinsta nta med as CAUTION When the system isinstantArmed you willnotbe able to enterthroughany perimeterdoororwalkthroughany protected area withoutsetting of
11. hisprocedure allowsyou to bypassone ormore zoneswhile yoursystem is DISARMED ax NOTE System programming determineswhich PINscan bypasszones also which zonescanbe bypassed To leamifa zone canbe bypassed see the ZONE DESCRIPTION UST on pages 41 42 adio Enter your PIN if required LL Ld D Push the key enterthe zone to be AJL ALEN bypassed then push the key INOTE Zonescanbe also be bypassed by remote programming When remote pro gramming isused the sytemcaneitherbe armed ordisa med 14 Aaming the system PN Tobypass mor than one zone enter your Le Le LJ E REQUIRED PIN if required push the key enterthe first zone to be bypassed push the key A A again enterthe nextzone to be bypassed all Leal LEN and so on Whenthe lastzone to be bypassed hasbeen entered pushthe key To indicate thatzoneshave beenbypassed the READY lightand the Z NElight will flash slowly The red ZONElightsofallb ypassed zoneswillfla sh to remind you that bypassed zonesare notprotected The procedures foradding a bypass and removing a bypass are identical To remove a bypass enteryourPIN push the g ey enterthe zone from which the bypassisto be removed then push the key When you have finished bypassing zones armthe system by entering yourPIN and pushing the key I NOTE Disarming your alarm system REMOVES all bypasses except 24 hour zones 15 Maming op
12. imes then enteryour PIN again 18 sifter an alarm AFTER AN ALARM OCCURS mer your PIN and pus ine E E G U EA key Thiswillsilence the siren belland disarmthe system The red ZONElightson the keypad willfla shto help you remember where the violationsoc cured Ifthisisa false alarm and no emergency response is needed call our central station IMMEDIATELY at 4P to cancelthe alam Write downthe numberofthe triggered zonesto help usservice you Clearthe alarm memory and red ZONE lights by pushing the key entering the digit 1 Lal i Leal then pushing the key 19 Options orron 24 HOUR MONITORING C With thisoption insta lled yo ura la m system willtra nsmitalarm signa Isto ourcentralstation orton EMERGENCY KEY Holding the A key down forthree sec ondswilltriggeranalam The keypad willbeep twice to confimthe alarmcondition as NOTE The System 238 and System 2316 have notbeen investigated by Underwriters Laboratoriesforcompliance with UL1637 Home HealthCare Signalling Equipment orron FIRE KEY Coy rs When thisoption isinsta lled holding down th amp keyforthree secondswilltriggeranalam The keypad willbeep twice to confirm the alarmcondition 20 Options OPTION INSTALLED OPTION INSTALLED POLICE PANIC KEY cy When thisoption isinsta lled holding down
13. ndby battery push the key preg digit 6 the digit aly then push KE La LEN the key The standby batterytesta kes2 minutes During the test the green AC lightwillbe off Ifthe batteryisokay the keypad willbeep twice Ifthe battery islow ordead the POWER light will flash slowly the SERVIC E light willbe onsteady and the keypad willbeep five times __ BELL SIREN TEST Cyc cycy To test the bells sirensin yoursec unty system Enter your PIN if required push the key KE ER ES enter the digit 6 the digit 3 then push the key The bell siren and keypadswillsound for3seconds 33 Testing gour system OPTION INSTALLED PIN REQUIRED CENTRAL STATION TEST Thisoptionteststhe reporting capability of yoursystembysendinga testmessage to the centralstation Weekendsare the besttime forthe CENTRAL SIATION TEST To schedule one call ourcentral station at CENTRAL STATION AP To initiate the CENTRAL STATON TEST Enter your PIN if required Ly Ly Ly push the key enter the digit 6 the digit 1 then push the key Le elie Ifthe testmessage wassuc cessfully transmitted to the centralstation the keypad willbeep twice Ifthe test message wasnotsuc cessfully transmitted to the centralstation the keypad willbeep five times and the SERVIC Elightwillflash ra pidly CallourService Departmentforassistance 34 Telephone trouble F YOU HA
14. sytemammed ordisarmed successfulcentralstation testorbatterytest 5beeps wrong PINnumberentered invalid function unauthorzed commandattempted enorchanging PIN number continuoustone beeping fastforlasttenseconds entrydelaytime continuousbeeping speeding up forlasttenseconds exitdelaytime 2secondbeep doorchime ting backafterclosng report zonefaulted during walk test chirping lsecond on 4sec ondsoff chirp alertwaming systemisammed but a Delayzone isfaulted you mustdisarm the system before entrydelayexpiresoralamwilloccur zone programmed to chirp isin a la m continuoustone zone programmed fortea dy bellorsren isin alam circ uitmalfunction trouble onsupervised loopsonly pulsed tone 2secondson 2secondsoff zone programmed forpulsed bellorsirenisinalarm Saming the system TO ARM THE SYSTEM 7 Make sure the green READY light is on Ifthe READY lightisnoton the red ZONE lightswillindic ate which zone s are faulted Faulted zonesmustbe cleared orbypassed before the sytemcanbeamed Formore information referto the sectionsBypassing Zonesa ndAfterAn Ala m dti Enter your PIN and push the a Vv key YourPINnumbercanbe froomtwo to five digitslong Don tpause formore than 5sec ondswhile entering the digitsorthe c ontrolpanelwill rejectyourPIN number Ifyou make a mistake while entering yourPIN number the keypad willbeep five times A
15. te the PINsof Users 2 8 Enter your Master PIN push the key enter the digit 0 then push the ENTER key The READY ARMED and SERVICE lights will flash sowlyto indicate programming mode Enter the User number 2 8 you wish to delete and push the key lt 3 Enter the User number you wish to delete again and push the key l Exitthe programming mode by pushing the key then the key a ee ee j ee KE EF E EA Cal N ES ES 26 Options CHANGING A SYSTEM 2316 AND 23161 USER PIN User 1 can use the Master PIN to change the PINsof Users 1 32 See Below Enter your Master PIN push the i key enter the digit 0 then push the key Cogley The READY ARMED and SERVICE lights will flash Sowlyto indicate programming mode Enter the User number 1 32 and push l j BI j the key USER NUMBER Enter the new PIN and push D ee Le The new PIN canbe fromtwo to five digitslong NOTE On System 2316i UserC ode 82 isreserved forspecialfunctionsusing the OptionalRelayOutputModule 27 Options Enter the new PIN again and push Lyle yea le the key Ifthe new PIN isaccepted the keypad willbeep twice Ifyou make a mistake while programming orifthe system rejectsthe new PIN the keypad willbeep five times Exitthe programming mode by pushing the key then the key Las Lali Make sure the new PIN works Afterle
16. th key forthree secondswilltiggeranala m The keypad willbeep twice to confimthe alarmcondition DURESS ALARM 238 and 2316 ONLY Should an intruderforce youto tum yoursec unty system offoron youcan send a silent DURESSsignalto ourc entralstation byadding orsubtracting 1 from the last digitof yourPIN Forexample if yourPIN is 1 2 3 4 enter ing 1 2 3 3OR1 2 3 5willtriggera silentalarm Yoursystem willappearto be operating nomally There willbe no indication ofanalarmcondition IfyourPIN endswith a 0 entering 9 or l instead ofthe O willtiggera DURESS signal IfyourPIN endswitha 9 entering 8 or 0 instead ofthe 9 willtrhnggera DURESS signal 21 Options on DURESS ALARM 238jand 2316 ONLY Should an intruderforce youto tum yoursec unty system offoron youcan send a silent DURESSsignalto ourcentral station by entering UserC ode 7 a code designed exclusively fora DURESSsig nal Yoursystem willappearto be operating nomally There isno indicationofanalarmcondition 22 Options GUEST COMBINATION The SYSTEM 238 can store up to 8 PINs and the SYSTEM 2316 can store up to 32 PINs In both systems PIN 8 can be programmed asa GUESTCOMBINATION that willonly be valid fora specified numberofsuccessive days The countdownofdaysbeginsthe firsttime the GUEST COMBINATION is used NUMBER OF DAYS GUEST COMBINATION IS VALID Once the time
17. tions Youralarmsystemhasbeen programmed forone ofthe following three arming types omon GOOF PROOF ARMING INSTALLED x C Ifanyzone otherthana 24 hourzone isfa ulted open window malfunction ing sensor etc yoursystem willnota m Youwillnotbe able to amthe system untilthe fa ulted zone iscleared ormanuallybypassed ORTON FORCE ARMING Any zone exc eptfor24 hourzones thatisviolated afterthe EXITDELAY time hasexpired willbe automatically bypassed untilthe system isdisarmed Waming bypassed zones are not protected 16 Maming options on CHIRP ALERT The system willamevenifdelayzonesare faulted atthe time ofa ming Ifa zone istillfa ulted when the EXITDELAY time expires the bell siren will beginto chirp The chiming willc ontinue forthe duration ofthe ENTRY DELAY time You musre enterthe premisesand disa mthe system before the ENTRY DELAY time expiresoran alam willoccur 17 Disarming the system TO DISARM THE SYSTEM q Enter only through a TIME DELAY door ornon _ If the ENTRY PRE ALARM optionisinstalled the keypad willsound constantly until 10 oo secondsbefore the delaytime expires orthe panelisdisarmed thenbeep rapidlyfor the last10seconds PN Enter your PIN within Ei A ace key E Le Make sure the red ARM lighton the keypad goes off Ifthe ARM lightdoesnotgo off waitforthe keypad to beep five t
Download Pdf Manuals
Related Search
Related Contents
Zeppelin Bedienungsanleitung Télécharger ce fichier - hélicoptères Télécommandés 2468 フュートレック OPERATING INSTRUCTIONS MANUAL FOR “FMS DIGITAL 取扱説明書 Copyright © All rights reserved.
Failed to retrieve file