Home
        GUARDIAN PLUS™ CM-1701 USER MANUAL
         Contents
1.       Strategies  Solutions  Innovation       GUARDIAN PLUS    CM 1701 USER MANUAL    DESCRIPTION   This Guardian PLUS     CM 1701 is a single person and workstation continuous monitor  The first channel monitors  the path of the ground to the operator wearing a single wire wrist strap  The other channel monitors the path of the  ground to the ESD work surface  Table Mat   When using the monitor  any breaking of the path to earth electrical  ground of operator wearing a wrist strap or breaking the path to earth electrical ground the work surface  Table Mat   would be known at once because of the blinking RED LED and piezo buzzer  The operator or work surface  Table  Mat  is always connected to ground automatically even when the on off switch is in the off state  The Guardian Plus  CM 1701 thus becomes a common point ground even when the CT 1701 is in the off state     IMPORTANT  Always connect the Guardian Plus CM 1701 to earth ground     INSTALLATION    1 Connect this equipment to the earth electrical  ground  of the building  This equipment comes with a grounding  wire  One end of the ground wire is connected to the back of the CM 1700  The other end is connected to the  earth electrical ground   FIGURE 1    Always check that the electrical ground is correctly attached    2 Connect the CM 1701 to the ESD work surface  Table Mat  by using a cord with banana plug  Not provided  See   FIGURE 1      3 Connect the ESD work surface  Table Mat  to the earth electrical ground the m
2.  the resistance of the path  Work surface   Table Mat  to ground  is higher or lower than the preset value  the green LED of its testing side will change from a  green LED to a flashing red LED and buzzer alarm     SPECIFICATION    Power source  9V DC adaptor    Preset impedance  Operator   The wrist strap person adjustment can be changed The monitor can be changed by  turning the adjustment screw to another value  FIGURE 2   depending on the weight and or height of the user   Preset resistance  Work surface  Table Mat    This is 10 Meg ohms  This can be adjusted to a different value    FIGURE 2   Merely turn the adjustment from 10Meg to 5 Meg or 11 5 Meg Ohm     ADJUSTMENT    Operator   A 5 Meg Ohm  original setting  was used to set up and calibrate the CM 1702  In case the user has lost or wants to  recalibrate the setting connect a Smeg ohm resistor between the ground and banana jack for wrist strap  Then turn the  calibration knob in Figure 2 until the LED    JUST    changes from flashing red LED to solid green LED to a flashing  red LED     Work surface  Table Mat    A 10 Meg Ohm  original setting  was used to calibrate the CM 17as example in case the user has lost on setting   Firstly  connect a 10 Meg Ohm resistor between the ground and banana jack for work surface  then turn the knob in  Figure 2 until the LED has    JUST    change from flashing red to green or green to flashing red     TROUBLESHOOTING    Operator   The red LED is always flashing red with a buzzer ala
3. at must have a conductive layer   See  FIGURE 1      4 Connect the 9VDC power adaptor to the back of the equipment  The other end is connected to AC power supply of  the building See  FIGURE 1      5 The CM 1701I monitor may be installed either under or on top of the table or workstation  There are two holes and  enclosed screws which can be used to attach the monitor to the workstation  Two sided pressure sensitive tape or  hook loop Velcro may also be used     YOU MUST CONNECT TO GROUND WHEN USING THIS EQUIPMENT    et 9 VDC C     CONNECT TO Work surface  Table Mat      p  WORK SURFACE    L PASS  GREEN        OFF AND        PASS  GREE         Connect to earth of the building  by using our grounding cord  or any  gentle metal wire     Adjust the trigger resistance    Connect to our DC adaptor  the of work surface  Table Mat   other end is connected to the  120VAC power       Connect to earth of the building       Adjust the trigger impedance  resistance   of operator    FIGURE 1  FIGURE 2     OPERATION    Operator   When the path of the ground to the operator wearing the wrist strap is broken or the installed resistance of wrist strap  is higher or lower than the preset value  This mean the impedance of the user  wrist strap and ground is higher than  the preset value   the green LED of its testing side will change from the green LED to flashing red LED and buzzer  alarm     Work surface  Table Mat    When the path of the ground to the work surface  Table Mat  is broken or if
4. our work surface  just turn the resistance setting pot to lower  sensitivity    4 The earth wire of the building is not connected correctly to the earth      gt  331 Boston Post Road East   Marlborough  MA  01752   gt  tel  508 480 0700 fax  508 485 3353   gt  www staticsolutions com contactus staticsolutions com    
5. rms even the user wears in specification wrist straps    1 The wrist strap is broken in the coil cord    2 The wristband on the operator is not connected correctly to the skin of the wrist  Check to see if the strap is in  contact with the skin of the operator  Use an ESD hand lotion if necessary   3 The equipment is not connected correctly to earthy electrical ground    4 The impedance setting is not calibrated correctly to the operator due to the difference in weight or height Turn and  adjust the impedance setting pot inside the rectangular hole in the front panel  FIGURE 2   to a lower or higher  sensitivity    5 The building ground wire of the building is not in good contact with the to the earth ground      The LED is always on the green    PASS    state even the user is not wearing the wrist strap but has laid the wrist strap   on the ESD table mat or ESD work surface    1 The sensitivity of the impedance is too low  You need to turn and adjust the impedance setting pot inside the  rectangular hole in the front panel  FIGURE 2   to higher sensitivity     Work surface  Table Mat    The LED is on flashing a RED LED and alarms the buzzer even if the connection is well attached as in Figure 1    1 The work surface  Table Mat  is not well connected correctly to the earth or electrical ground    2 The connection wire between the CM 1701 and work surface  Table Mat  is broken or contains some internal  resistance    3 The resistance setting does not fit to the resistance of y
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
BACTEL  カタログ  PC-NJ70A トラブル解決ガイド  important safety instructions do not reach into the water save th instruct  Philips VisaPure SC5265/12  BUW-0255-12 LaserMeter50 Web FR.indd  SDA 23 - Fabco Automotive Corporation  M-Cab 100m SAT Coax  Whirlpool RH4300XL User's Manual  Instruction Manual - Sunpentown International, Inc.    Copyright © All rights reserved. 