Home

PowerPanel Business Edition User`s Manual

image

Contents

1. 63 CyberPower Reliability Quality Value Using the Previous and Next at the upper right corner of the event log list helps users to view the other range of filtered log result backward or forward Clicking Refresh will update the log result to display in the list according to the current filter options and paging settings The time displayed at the upper corner displays the local time of the hosted computer This time may be different from the time on your computer Detailed power status from the time of the event can be viewed in a pop up window when moving the mouse over a selected event 2009 09 01 01 03 09 AM 2009 09 01 01 03 09 AM 2009 09 01 01 03 09 AM 2009 09701 01 02 44 AM 200909701 01 02 12 AM 2009 09 01 12 34 46 AM 20090831 11 35 21 PM 20090831 11 01 25 PM 20090631 11 01 19 PM Event Communication with device E Output voltage is being boos Input Volt 110 5V Utility power has been resto Output Volt 109 6V Supplying Communication with device Input Freq 59 9Hz wer ewent Communication is establishe Load de Capacity 99 SE Runtime 7 hr 12 min Communication P establisheo gt or ablished at startup Utility power failure battery Communication is es The Battery test was successful battery is healthy Process battery test to verify that battery power can be provided normally A pop up status window is displayed from the selected event Filter
2. Device 192 168 2692 failed to be added POU POU 1SSWEFNET 192 168 2651 was added 3 devices were added UPSIPDUZOSWHVT 1SATNET 192 168 26 91 was removed VPS POUSOSWHVT1ISATNET 192 168 2691 was added ATS POUS0SWHVTISATNET 192 1658 26 91 was requested to moved fom group UPS to group ATS 2014 12103 03 44 20 UPS RMCARD203 192 168 26 88 was added 2014 12 03 03 43 17 2 devices failed to be added 2014 11 28 03 52 55 POU PDU15SWSFNET 192 168 2651 was added 2014 11 28 03 50 59 UPS 2A42 IT 192 168 26 102 was removed 2014 1 1 28 03 50 55 go UPS RMCARD303 192 168 26 50 was removed 2014 1 1 28 02 29 08 The battery test on UPSIRMCARD303 192 168 26 50 was successful battery is healthy 2014 1 1 28 02 28 58 UPS RMCARD303 192 168 26 50 was requested to perform battery tested 2014 11 28 02 27 26 UPS RMCARD303 192 168 26 50 was added 2014 11 28 0226 43 UPS RMCARD202 192 168 26 108 was removed 2014 1 1 28 02 18 57 Q Failed to request UPS RMCARD202 192 168 26 108 to power cycle 2014 1 1 28 02 18 57 Q Failed to request UPS RMCARD202 192 168 26 108 to power cycle 364626544790 AD 12 428 w e ot ee ee ee WT ZS WT T XT a a Se ee aan T BR i 4 Page 141 zs i e Displaying logs 1 25 0f25 Clean Se Se SS SS WS ER ER SEER SW SS RSS Logs page Each log has details which can be viewed by clicking the icon next the each log Using the paging toolbar at the bottom of the log list allows users t
3. Copy the below example code and save as the new file named setup varfile installModule agent_or_client installationDir ppbe_installation_directory profilePath exported_zip_location Users can assign the installation module installation directory and the located folder of the profile installModule Sets which module wish to install This should be agent or client installationDir Assigns the absolute path of the installation directory of PowerPanel Business Edition e g C Programs CyberPower PowerPanel Business Edition PowerPanel Business Edition or opt opbe profilePath Assigns the absolute and complete path of the profile which is located e g C Import profile zip or import profile Zip CyberPower Reliability Quality Value Place the setup varfile and installer in the same directory and make sure that filename must be the same e g setup exe and setup varfile Different filename will result in unknown fault during installation For Windows run the below command to launch the installation in the command prompt setup exe g console Dinstall4j detailStdout true For most Linux distributions run the below command to launch the installation in terminal sudo setup sh q console Dinstall4j detailStdout true After the installation is complete the profile will be imported and all settings will be applied successfully Note When you would like to upgrade the pre installed Agent or Client during th
4. Inputs both fail ATS doesn t switch input source ATS doesn t switch the source due to both input sources are power failure When the current source of ATS is power failure ATS attempts to switch to another source which is functioning well If both sources of ATS are power failure at the same time the ATS cannot switch to another source Switch to redundant input source of ATS automatically When the current source of ATS is power failure and another redundant source is functioning well ATS will switch to the redundant source to afford the power to its load Redundant input source of ATS is power failure The current source of ATS is functioning well but the redundant source is power failure In this situation once the current source is power failure ATS cannot switch to redundant source to afford power to its load ATS is faulty ATS has malfunctioned in internal More events are available for the environment sensor within UPS PDU ATS in Client Environment sensor is no response Environment sensor of the UPS PDU ATS has no response The sensor may be malfunction or removal from the UPS PDU ATS Environment temperature is overheated The temperature is measured by the sensor exceeds the high threshold Environment temperature is undercooled The temperature is measured by the sensor violates the low threshold Environment humidity is over wet The relative humidity is measured by the sensor exceeds the high threshold
5. Session Timeout Never Security Login page Account Change Username Enter the password in the Current Password field Select the Change Username option and enter a new username in the New Username field Username must be alphanumeric 0 9 A Z and a z Click Apply to complete the change Change Password 70 CyberPower Reliability Quality Value Enter the password in the Current Password field Select the Change Password option and enter a new password in the New Password and Confirm Password fields Click Apply to complete the change Session Session Timeout is the option which determines the duration of the session after the login If the page isn t accessed during this period and remains inactive users will be logged out automatically Users will need to login again on the Login page Authentication To secure and protect network communication between the PowerPanel applications and the devices security settings must be configured in the Security Authentication page The Secret Phrase and SNMP settings are be configured and used for authenticating network communication between the PowerPanel applications and devices such as PDU or UPS Authentication PowerPanel Secret Phrase powerpanel encryption key SNMP Protocol Version SNMPv1 SNMP Comn private SNMP Trap Communit public SNMPv3 Jser Name S4uthentication 4uthenticatio Prvaci Protocol rrivacy Ke Securit
6. The following filter options can be utilized by selecting Filter in the upper right corner Once the configuration of the filter pane is configured the logs will be requested and displayed Event Logs Days 2009 08 30 Partial entries are fatered Display of 2010108719 10 35 pm Fitter D x FH Al Thisday Lastday Previous day Nextday Thatday Time 12 00 AM Le 11 00PM Le All Duty On Duty Off Weekday Sun Mon W Tue F Wed F Thu F Fri 7 Sat All Working Rest Severity Severe Warning V Information Category System Event V Power Event All Events Max logs 100 Le Filter pane on Logs Event page in Agent Days Selects the day s for the events to be displayed The dropdown menus next to the Days setting can be used for additional preconfigured filters Time Selects the time range for the events Weekday Choose the days of the event occurrence Severity amp Category The events can be filtered by category and severity The events can be further divided by Power Event and System Event categories and choosing the specific event Even the events can be also filtered 64 CyberPower Reliability Quality Value out by the specific device type in Client When any event option is selected from the event list the logs only related to this event will be displayed Max logs Indicates the maximum number of events that will be displayed Export Click the Save shortcut at th
7. Inverter Overload The module inverter is overloaded Inverter Extended Overload The module s inverter has been overloaded for intolerable duration the UPS will stop output power soon Fan Fault The module fan is faulty It may cause overheat in module Shutdown The module has been shutdown and stopped its output power Information UPS Information Information Model PRIOCOLCORTAL2Ua Firmware Version 1 3 5 UPS Type Sine Wave Line Interactive VA 1000 VA Power Rating 750 Watts Voltage Rating 110 130 V Frequency Rating 47 63 Hz Battery Replaced Date 2009 06 10 Reset NCL Outiet 1 Extended Battery Pact 1 installation Place Find it UPS Information page of a PR1000LCDRTXL2Ua The UPS Information page shows information about the UPS Model The model name of the UPS Firmware Version The firmware version of the UPS Serial Number The serial number of the UPS UPS Type The type of the UPS e g On Line Line Interactive or Sinewave Line Interactive Power Rating The Volt Amp rating and power rating Watts of the UPS Current Rating The output current rating Amps of the UPS CyberPower Reliability Quality Value Voltage Rating The input voltage range Volts of the UPS Frequency Rating The input frequency range Hz of the UPS Battery Replacement Date The date that the batteries were last replaced This can only be set at the time of battery replacement This date should be set after the ba
8. Run command files for custom applications Historical logs of events and power conditions Detailed load management for all powered equipment scheduled shutdown and restart Status monitoring of the UPS and utility power UPS configuration Quick view system summary Client The Client provides unattended shutdown for the hosted computer following a notification from the UPS PDU ATS The Client also provides the following functions Unattended shutdown in response to various power conditions User notification of power conditions Flexible configuration of actions for each specific event and notifications via E mail Instant Message and SMS Historical logs of power events Quick view system summary Center The Center provides users the following functions for multiple Simultaneous monitoring of multiple UPS PDU ATSs equipment and computers which have Agent or Client installed Control access to all monitored UPS PDU computers and equipment Detailed load management between UPS PDU ATS and all powered computers equipment Equipment groups for easy monitoring or individual access Viewing additional information and status of monitored UPS PDU computers and equipment Historical logs for events and results about demands to power management CyberPower Reliability Quality Value Getting Started Prerequisites Hardware Limitation 733 MHz or higher Pentium compatible CPU 256 megabytes MB of
9. PDU Outlet and ATS Outlet Indicates which power outlet of the UPS or PDU ATS is supplying power to the computer that has been installed PowerPanel Business Edition Client software The outlet list will be updated after entering a network address of UPS or PDU ATS Outlet preview will be shown with a selected outlet accordingly for assisting to verify whether the computer is connected to the proper outlet The Identify button is only visible after the Client has established communication with the network PDU the identification function helps to identify which outlet has the connected equipment The PDU will blink the outlet number on the LCD screen to verify the actual connection on the PDU matches when the Identify button is pressed How to Configure Proper Power Connection In order to identify the difference between the power connections the proper power connection should be chosen accordingly If Client only connects with single UPS or single PDU the Power Connection should be set UPS or PDU Enter the required IP address and assign the correct outlet Click OK to establish communication Note The UPS must be installed a standalone RMCARD or controlled by a computer which has been installed the Agent the PDU must have the network function If Client connects with a network PDU that is a power extension from the UPS the Power Connection should be set UPS with network PDU Enter the IP address of UPS Enter the IP address of PDU and assign
10. PPBE Client option and click OK to finish Modify the Equipment You can modify the Name Location and Contact fields of equipment Enter the new data and click OK If the Installed PPBE Client option is enabled this indicates the generic equipment will be changed to a computer which has PowerPanel installed Refer to Attach New Generic Equipment for further details If the nstalled PPBE Client option is disabled this indicates that a computer has uninstalled PowerPanel and will become generic equipment If one computer which has PowerPanel installed replaces another existing one on the same outlet change the Address field and Center will attempt to establish communication with the new computer Rename the Equipment Select the Rename item from the context menu and a rename window will appears Click OK to rename the equipment User can also rename the equipment by modifying the Name field in the Settings tab of the Details window IT Equipment Details Summary The Summary tab provides the operating status of the UPS PDU ATS and which outlet it is plugged into 98 CyberPower Reliability Quality Value Name The name of the UPS PDU ATS Status The operating status of the UPS PDU ATS Outlet Indicates the outlet number of this current equipment It also indicates whether the outlet type is NCL Battery or CL Settings The Settings tab allows you to configure powered equipment Enabled If this option is checked
11. Reliability Quality Value Troubleshooting the Client s inability to communicate with the power device Verify the network address is correct Verify the network configuration for the UPS or PDU is correct The Power Device Network Utility tool can be used to configure the network configuration The tool can be installed from the tools folder on the installation CD Verify that the settings in the Security Authentication page are correct and match the settings of the device See Security Authentication for more details Verify the port in the Security Network page is matched with settings of PowerPanel Business Edition Agent Check that the network status of computer and devices Verify that firewall settings Port 3052 UDP TCP port 53568 TCP port 162 UDP and port 53566 UDP should be unblocked The computer communicates with the power device on these ports The installer of PowerPanel software will automatically configure Windows firewall to allow PowerPanel Applications to access through firewall Verify that SSL certificate of Client has been added into the trust list of Agent If the Client applies the new SSL certificate and not available in the trust list this will result in communication loss Event Action An event is generated when the UPS PDU ATS encounters specific power conditions The PowerPanel Business Edition software can be configured to respond to specific events and perform actions based on the event
12. The UPS Status page displays detailed status on the UPS power conditions batteries and system 24 CyberPower Input Reliability Quality Value UPS Status Input Status Normal Voltage 109 1 V Frequency 59 9 Hz Output Status Normal Voltage 109 9 V Frequericy 59 9 HI Load NCL 1 NCL 2 Battery Status Fully Charged Capacity 100 Voltage 42 5 V Remaining Runtime d hr 20 min Remaining Charge Time D min System Status Normal Temperature UPS Status page of a PR1000LCDRTXL2Ua Status Displays the present status of the utility power supplied to the UPS Normal The voltage and frequency of the utility power is normal Blackout There is no utility power being supplied to the UPS and it is supplying battery power to connected equipment Over Voltage The utility voltage is higher than the high voltage threshold and the UPS is using the battery to supply power Under Voltage The utility voltage is lower than the low voltage threshold and the UPS is using the battery to supply power Frequency Failure The frequency of the utility power is out of tolerance and the UPS is supplying battery power with a fixed frequency Wiring Fault The UPS has detected a wiring fault in the outlet it is plugged into No Neutral The neutral wire is not connected well Generator Detected UPS is being supplying power by generator Power Failure The utility power being supplied to the UPS is not qualify due
13. VM All Programs Je CyberPower PowerPanel Business Edition PB PowerPanel Business Edition Agent Log OFF Turn OFF Computer Launching PowerPanef Business Edition software on a local computer On Linux users can enter http localhost 3052 in the address of the web browser to access the interface Users can also enter the URL http localhost 3052 in the local computer or http hosted_computer_ip address 3052 in the remote computer to the address field of the web browser to access the PowerPanel Business Edition software web interface hosted_computer_ip_address is the IP address of the computer which has the PowerPanel Business Edition software installed For vMA on the ESX or ESXi hosted_computer_ip address is the IP address of the vMA Note hosted_computer_ip_ address is the IP address of the host computer on ESX PowerPanel Business Edition supports multiple language function and allows users to change language It will choose the suitable language as the default one to display at the initial access Users can change the language from the banner After the language is changed the page will refresh automatically and choose the assigned language as the default one to display 20 CyberPower Reliability Quality Value Agent on P8IT35 192 168 159 1 e English System summary BAGS Francais Summary Polski The UPS is working normally TERS P Sz Deutsch EEP Change language Login T
14. Windows 2003 or Windows XP and or on a different computer the service will work normally The recipient on the remote computer should be formatted as Server name Users name m If PowerPanel Business Edition and the recipients are on Windows Vista Windows Server 2008 Windows 7 Windows Server 2012 or Windows 8 and then the alert messages will only be sent to a local user account on the computer running PowerPanel Business Edition Note Computer Name filed and Alert column are only available on the PowerPanef Business Edition which installed on Windows On Linux if Linux Message service is activated the message will be sent to all users on the computer Mobile Phone Number The mobile number of the recipient to receive the mobile text message It must contain the country code Activation Day Configures the days on which recipients can receive the notification Users can define the specific ways to notify the assigned administrators on different days Activation Time Configures the time which recipients will receive the notification Users can define the specific ways to notify the assigned administrators during different times Device Sources Selects the device sources for each recipient to receive the notification In case of power events from these selected device sources the recipient will receive the notification Note This field is only available in Center Enabled Displays which notification s are active for the r
15. the result and the date of the last calibration When a runtime calibration is initiated the connected equipment will be run on battery power until the batteries are completely discharged The batteries will be then automatically recharged following the calibration Users can click the Start button to initiate a runtime calibration Click the Cancel button to interrupt the runtime calibration The result will be reported after a calibration is finished or canceled Estimated Runtime The estimated runtime of the batteries Last Calibration Result The result of the last runtime calibration m Passed The runtime calibration completed and the batteries are good m None The UPS has never performed a runtime calibration WR Failed The UPS failed during the runtime calibration H Canceled The calibration was interrupted Last Calibration Date The date the last runtime calibration was performed Alarm Test The Alarm Test allows users to verify that the alarm can beep normally and shows the date of the last test Click the Initiate button to begin an alarm test The details will be reported after an alarm test is complete Last Processing Date The date the last alarm test was performed Indicator Test Indicators on the front panel or on the LCD screen are used to present the UPS status Once the indicators are malfunctioning users won t know the current UPS status The Indicator Test allows users to ensure whether indicat
16. this indicates that this outlet is being used by the computer or the equipment you assign Installed PPBE Client Determines whether the item is generic equipment or a computer which has Agent or Client installed IP Address The IP address of the Agent computer Client computer or the equipment on this outlet When the nstalled PPBE Client option is checked the Client IP address is necessary to search for the Client computer Name The name of the computer or equipment Location Where the computer or equipment is Contact Who to contact about this computer or equipment IT Equipment Operations Shutdown Restart Select Shutdown or Restart from the context menu and a confirmation window will appear Click OK to initiate the shutdown or restart This is only valid for a computer with Agent or Client installed Power Control Power Off Select Power Off from the context menu Decide whether to turn off the outlet immediately or in sequence Click OK to begin A computer which has Agent or Client installed will initiate a graceful shutdown prior to turning off the outlet On specified modes turning off or restarting one outlet of the bank will also turn off other outlets of this bank This may cause other computers on this bank to be shut down unexpectedly Power On Select Power On from the context menu Decide whether to turn on the outlet immediately or in sequence Click OK to turn on the outlet Power Cycle Select Power Cycle f
17. 2 CyberPower Reliability Quality Value Boost Charging Boost charging involves a high current for a short period of time to charge the battery Boost charger enables the quick charging of depleted batteries m Float Charging The float charger starts charging the battery by exerting a charging voltage As the battery is charged its charging current reduces gradually The float charger senses the reduction in charging current and reduces the charging voltage Exhausted Batteries are exhausted UPS stops the output power Reversed Connection Connection between UPS and batteries is wrong on electrical polarity Capacity Critically Low The battery capacity is too low and the UPS may shut down immediately Not Present There are no batteries present in the UPS Testing The UPS is performing a battery diagnostic test See the UPS Diagnostics page for more details about the test results WR Normal The batteries are working normally Voltage The present voltage supplied by the batteries Remaining Runtime The amount of time that the UPS can supply power to its load Remaining Charge Time The remaining time the batteries required to be fully charged Capacity The present capacity of the batteries expressed as a percentage of full charge System Status Displays the present operating status of the UPS WR Normal The operating status is normal Fault The UPS is in fault state due to an internal malfunction O
18. Access Control or Network Service SNMPv1 Service page in the UPS remote management card RMCARD web or on the Network SNMP Settings or Network Service SNMPv1 Service page in the PDU web Outlet Off Delay Setting Specify the necessary time for the Client to shut down the computer on the Outlet Outlet Configuration page in the PDU web Add the IP address of the Client computer to the Trap Receiver list of the UPS RMCARD PDU ATS on the Network Trap Notification page in the UPS RMCARD web or in the PDU web CyberPower Management Console Logged in cyber Monitoring Access Control Current Status 2 w Information Manager IP Community Permission UPS Control OO00 public Read Only UPS Reboot 0 0 0 0 private Write Read Schedule System System Time dnij We User Accounts Identification Network TCP IP Access Control Trap Notification Events Event Log Event Generation UPS Shutdown Summary Logout r Network Access Control page in the UPS RMCARD201 web SNMP Trap Community The Client uses the community to authenticate the SNMP trap from a secure device The community default is public The IP address of the Client computer must be added to the Trap Receiver list on the Network Trap Notification page of the UPS RMCARD and the PDU to ensure the community is matched CyberPower Reliability Quality Value CyberPower Management Console Logged in cyber Monitoring Trap Notification Current Status UPS In
19. Linux and VMware ESXi only PowerPanel Business Edition Client can be installed The default installation directory is usr local ppbe on the Linux platforms and opt ppbe on VMware ESXi Execute the uninstall sh command in the installation directory to uninstall the program 10 How can I get a notice when a power condition has cleared 126 CyberPower 11 12 13 14 15 16 Reliability Quality Value When a power condition is clear it will broadcast a notification and also run the command file A custom script can be created for events The script can utilize the environment variable EVENT_STAGE to compare the key OCCUR to identify an event that has occurred or FINISH to identify an event that has cleared What network protocol is used in PowerPanel Business Edition SNMP is used on communications between Client Center PDU or UPS with remote management card HTTP and HTTPS are used between the Agent and the Client What the network ports are used by PowerPanel Business Edition Port 3052 UDP TCP port 53568 TCP port 162 UDP and port 53566 UDP I try to set the Client to establish to communication with one of PDUs How do identify the targeted device IP Refer to the Easy to Setup Device IP for details How do I ensure that the SNMP settings between the Client and UPS PDU ATS are properly setup To receive the trap notification from the UPS PDU ATS all the time follow steps to verify the SN
20. OK button will attempt to establish communication with the device at the specified IP address Add Device Device Address 192 168 10 205 197 168 24 71 Name Location IP Address Type OL2000RMX Server Room 192 168 10 205 UPS LI OL2000RMX Server Room 192 168 2471 UPS Cl PDUI5SW Serer Room 192 168 2454 PDU EI POUI5SWs TF 192 168 2434 PDU OK Cancel Select IP address by clicking Browse button Move Device E Refresh Uptime 2h 37m 3 2h 3m 33s 47m 20s 137 days Highlight the device you wish to move and select Move in the context menu A Move window will display and select the target group from the list After selecting the target group click OK to move the group Remove Device Highlight the device to remove or click Remove in the context menu Click OK to remove the device When a device is removed its powered computers and equipment will also be removed Rename Device CyberPower Reliability Quality Value Highlight the device node you wish to rename and select Rename in the context menu The Rename Device window will display After entering the new device name click OK to apply the modification Device Details Each UPS PDU ATS provides further information from Details in the context menu This includes summary status and information When local communication or network communication is lost only the Summary tab can be accessed Details a
21. PDU Agent or Client on the Security Authentication page Setup that the port used by the Center on the Security Network page to match the port used by the Agent or Client Using PowerPanel Business Edition Agent and Client System Summary 22 CyberPower Reliability Quality Value System Summary Summary The UPS is working normally System Summary page in Agent In Agent the System Summary page provides an overview of the system operation This includes the utility power status operating status of the UPS issues with the system and items requiring user attention In Client the System Summary page provides an overview of the system including the communication status with the UPS PDU ATS issues with the system and items requiring user attention Information The content in this section is only applicable to the Client 23 CyberPower Reliability Quality Value Information Name ERP Server Location Server Room Rack A Contact Thomas tel 1234 System Information page The System Information page shows detailed information about the Client as follows Name The name of the hosted computer e g Web Server or Bill s Computer Location Where the hosted computer is located e g Server room or Rack A Contact Who to contact about this hosted computer e g someone s name E mail or phone number UPS The content in this section is only applicable to the Agent Status
22. PDU Information Device Type Model Firmware Version PDU Type Current Rating oltage Rating Outlet Name LocCabon Contact MAC Address IP Address POU PDUTISSWSFNET 0 980 Switched 12 0 Amp 100 120 V g PDUTSSWSENET Server Room Administrator 00 0C 15 40 06 D6 192 168 265 165 UPS Information Oevice Type Model Firmware Version Power Rating Curremt Rating Voltage Rating Frequency Rating Battery Replacement Date NCL Bank Extended Battery Pact Name Location Contact MAC Address iP Address UPS OLT500RTAL2ZU S1A05 1500 VA 1350 W 15 0 Amp 110 V 40 70 Hz 2073 10 05 1 0 RMCARDIO2 Server Room Administrator 00 0C 15 00 1F A0 192 168 26 118 Power Information page The Power Information page shows information about the UPS PDU ATS which supplies power to the Client computer When the Client establishes with a PDU which is connected to a UPS Information page displays the information about the PDU and the UPS individually Information illustrates as follows Device Type The type of the UPS PDU ATS e g UPS PDU ATS Model The model name of the UPS PDU ATS Serial Number The serial number of the UPS PDU ATS Firmware Version The firmware version of the UPS PDU ATS UPS Type The type of the UPS e g On Line or Line Interactive PDU Type The type of the PDU e g Monitored or Switched ATS Type The type of the ATS e g Monitored or Switched Power Rating The Volt Amp rating and pow
23. Summary T Status If reece Name RMCARD2015 Status Normal Location Server Room Contact Administrator6 Address 192 168 10 178 DS Equip 4 Power Source Utility Remaining Runtime 2h 15m Capacity 100 Details of UPS RMCARD Summary The Summary tab provides an overview of the system information Name The name of the selected device Status Displays the present status of the selected UPS PDU ATS Location Where the UPS PDU ATS is located Contact Who to contact about the UPS PDU ATS Address The IP address of the UPS RMCARD PDU or Agent computer s network interface PC amp Equip The number of the powered computers and equipment Outlets The amount of outlets on the UPS PDU ATS Outlet On The outlets which are supplying power Outlet Off The outlets which are not supplying power Power Source The power source of the UPS e g Utility or Battery Remaining Runtime The estimated amount of time remaining that the UPS can supply power given its current load Capacity The capacity of the batteries expressed as a percentage of full charge Statistics Indicates the state of the device as Normal Severe Warning or Lost 89 CyberPower Reliability Quality Value m Severe Devices with severe level events such as Overheat or Output is off m Warning Devices with warning level events such as Utility power failure or Battery need replacement m Lost Devices which have lost communication with Center Type
24. The type of software the selected device is running e g Agent Client or Equipment Current Source Indicates which input source is being using and will be also annotated preferred or redundant source Environment Sensor Indicates whether the environment sensor has been installed on the UPS PDU ATS Note When the sensor cannot be detected anymore it will be annotated No Response Users can click the Uninstall to reflect it if it had been removed physically from the UPS PDU ATS Status The Status tab displays details about the UPS PDU ATS Current The output current in Amps Outlets The status of each outlet on the UPS PDU ATS and the name of the connected computer or equipment Input Displays the status of the utility power supplied to the UPS Voltage The voltage of the utility power supplied to the UPS Frequency The frequency of the utility power supplied to the UPS in Hertz Output Displays the status of the output power that is being supplied to connected equipment Load Consumption The power draw of the connected equipment expressed as a percentage of the total load capacity This displays as watts on some UPS models Battery Displays the status of the battery packs Capacity The capacity of the batteries expressed as a percentage of full charge Remaining Runtime The estimated amount of time that the UPS can supply power to its load System Displays the operating status of the UPS Environment Temperature Indicat
25. UPS Diagnostics Battery Test Last Test Result Passed Last Test Date 2010 06 30 06 31 13 PM Runtime Calibration Estimated Runtime None Last Calibration Result Canceled Last Calibration Date 2010 06 30 06 31 31 PM Alarm Test Last Processing Date 2010 06 30 06 31 31 PM Indicator Test Last Processing Date 2010 06 30 06 31 31 PM UPS Diagnostics page Battery Test The Battery Test performs a battery test to verify that the batteries are good and shows information including the result and the date of the last battery test Click the Initiate button to begin a battery test Performing a battery test is prohibited when the Frequency Working Mode option is set to fixed The results will be reported after a battery test completes Last Test Date The date the last battery test was performed Last Test Result The result of the last battery test E Passed The battery performed normally during the test m None The UPS has never performed the battery test m Failed The battery test resulted in failure Follow the below steps if the battery test fails Repeat the battery test and replace the batteries if the test fails again Contact CyberPower for assistance if the battery test fails after the batteries have been replaced CyberPower Reliability Quality Value Runtime Calibration The Runtime Calibration ensures the runtime estimate is accurate with the current load The results show the runtime
26. an immediate or a sequenced power off Click OK to begin When the UPS PDU ATS initiates a sequenced power off computers with Agent or Client installed will initiate a shutdown prior to the sequenced power off An immediate power off will likely cause those lose power Power Off gt lt Below devices will switch off output power Name Directly PDU3S0SWHVT16FNET RSS server E PDU155W8FNET12 Power Off directly without seugneced delay OK Cancel A confirmation window of a bulk power off operation Power On Click Power On and a popup window appear Pick the UPS PDU ATS from the list and determine whether to perform an immediate or a sequenced power on Click OK to begin Note Some computers require manual booting when a UPS or a PDU powers on To change this set the computers BIOS to boot when power is restored Power On x Below devices will switch on output power Name Directhy PDOUSOSWHYVTI6FNET PDUTS5SWSFNET12 Bower Gn directly without seugneced delay OR Cancel A confirmation window of a bulk power on operation Power Cycle Click Power Cycle and a popup window appear Pick the UPS PDU ATS from the list and determine whether to perform an immediate or a sequenced power cycle Click OK to begin 96 CyberPower Reliability Quality Value Power Cycle x Below devices will restart output power Name Directly PDU3S0SWHVT16FNET e RSS server d PDU1I5SW8F
27. and General Provisions This Agreement will be governed by the laws of the State of Minnesota U S A excluding the application of its conflicts of law rules This Agreement will not be governed by the United Nations Convention on Contracts for the International Sale of Goods the application of which is expressly excluded If any part of this Agreement is found void and unenforceable it will not affect the validity of the balance of the Agreement which shall remain valid and enforceable according to its terms You agree that the Software will not be shipped transferred or exported into any country or used in any manner prohibited by the United States Export Administration Act or any other export laws restrictions or regulations This Agreement shall automatically terminate upon failure by you to comply with its terms This Agreement may only be modified in writing signed by an authorized officer of Cyber Power Systems USA Inc CyberPower Reliability Quality Value Table of Contents FTO CG UGTION PEME EE A E A A EAE E E E A S 7 e E 8 NS MU EAE E TE E saz e sees nes O cease vase TE N AA E A 8 CORET E E E EE EE E EE E E E E E E 8 cenno STN Ee e E dewusesa se ie pavseeseseseeedeccddesues auteunotsesieaueoesecsud 9 Seel 9 PROV AE o WE de EE 9 Operating SYS EE 9 e BON E 9 Me det 8 Je E dLeit ele E 8 Installation on ul se sect secrenrsta terecemasnmacendamenicauiesinembsateaateehnaiaiteiidaresacenett anieenGintaiesniaissannididanea
28. from the list After selecting the target group click OK to move the group Remove Group Select a target group and select Remove from the context menu A pop up window will open Click OK to remove this group Removing a group will not remove sub groups groups or computers and equipment belonging to this group These items will be moved to the main group Rename Group Choose a group and select Rename from the context menu A Rename Group window will appear and requires new group name to replace origin one Enter the new group name and click OK Note that a duplicate group name is not allowed Group Details Details SN Summary Group Name Block B Statistics Normal 18 Severe 1 Warming 4 Untouched D Type UPS 12 PDU 11 Summary tab of Details 102 CyberPower Reliability Quality Value Each group provides information about the communication state or the computer type from the Summary tab of Details Group Name The name of the selected group Statistics Indicates statistics about the operating conditions of the equipment belong this group WR Normal Indicates computers and equipment being monitored by Center WR Lost Indicates computers and equipment which have lost communication with Center Type Indicates computers that have Agent or Client installed or other equipment which are only being supplied power Group Operations Computers Shutdown Restart Select Shutdown or Restar
29. icon indicates it has been performed or expired Shutdown Time Configures when to perform the schedule and when to shut down computers Restore Configures whether to restore the controlled outlet power If the Yes option is selected the UPS will restore the power or power on the NCL outlet at the time specified in the Restore Time option Otherwise the UPS output will stay powered off Restore Time The time to restore the output or to turn on the NCL outlet This shutdown time must occur prior to the restore time The maximum duration between the turn off and turn on must depends on UPS model Returned Delay in the UPS Configuration page will affects Restore Time If a schedule is set to restore power at 6 00 PM and the Returned Delay is set 5 minutes the schedule will actually restore power at 6 05 PM Comment Sets the user defined comments for this schedule Note If the computer bios is set to boot when power restores the computer will automatically restart when the power is restored Consult your motherboard documentation or PC Server supplier for additional details CyberPower Reliability Quality Value Security Login The Security Login page is used to change the PowerPanel Business Edition login account information including user account password and the duration of login session Login Account Current Password Change Usemame New Username Change Password New Password Confirm Password Session
30. localhost cyberpowersystems com tw Normal 4 localhost cyberpowersystems com tw GA Normal Centos Normal Hyper v A ppbe250_client_centos Normal ppbe260_agent_centos I ppbe260_client_centos GA CH ppbe271_client_centos Normal GC ppbe280_client_centos Normal TEST XenServer Gel Win7 ULT Normal a FJ VMware vCenter Server Normal PS 192 168 10 132 192 168 26 160 Normal Service Infrastructure view Monitor the operating status from the infrastructures Define detailed action setting for each event of the infrastructure s power source Manage the service infrastructures Toolbar The Toolbar provides information about the status of the entire infrastructures and the option to add infrastructures The button allows users to add an infrastructure such as VMware vCenter server or ESXi host Indicates the devices which have lost communication with Center Center cannot monitor or control the VMware vCenter servers or VMware ESXi hosts when communication is lost Indicates that there are no problems with the VMware vCenter servers or VMware ESXi hosts Node Components 107 CyberPower Reliability Quality Value Each node has a name and an icon indicating what type it is Each node provides detailed information about what power events have occurred and what the current status is A context menu for each node is available by click
31. mail to deliver the messages to SMS providers Select the Using E mail option at the Service Provider field Insert EVENT ACTION PHONE NUMBER as recipient s mobile phone number and the EVENT ACTION MESSAGE as event message content described in the specification Fill in the Address Subject and Content fields The expressions will be replaced with relevant content before the Agent Client sends a notification to the SMS provider e g 62 CyberPower Reliability Quality Value Address sms send sms company com Subject xxxxxx Content user xxxxxx password xxxxxx to EVENT ACTION PHONE NUMBER text EVENT ACTION MESSAGE Note Each message sent by the SMS system through the SMS provider will be subject to the SMS provider fee Logs Event Logs Logs Event Logs page lets you view logs that record power event details in the Agent or the Client The logs can be analyzed to determine whether the system and the power device are operating correctly Event Logs Jul 21 2014 11 08 06 AM U Loca communication with the device has been ics Jul 18 2014 5 44 35 PM Jul 18 2014 5 44 35 PM Jul 18 2014 5 44 29 PM Jul 18 2014 4 12 54 PM Jul 18 2014 4 12 54 Pu Jul 18 2014 3 20 07 PM Jul 18 2014 3 09 57 PM Jul 18 2014 3 09 23 PM Jul 18 2014 2 58 26 Pu jul 18 2014 2 57 43 Pu Jul 18 2014 2 53 02 PM jul 18 2014 2 50 56 PM Jul 18 2014 243 54 PH Jul 18 2014 2 41 47 PU Jul 18 2014 2 24 36 PM Jul 16 2014 2 13 06 PM Jul 18 2014 2
32. or serial connection Installation on Hyper V Server Use the PowerPanel Business Edition installation CD to complete the installation on the target computer Run the lt CD_Drive gt Software Windows setup exe of the command prompt such as below illustration to start the installation 19 CyberPower Reliability Quality Value procedure CD_Drive is a CD drive formatted as D or E Apopup window will be displayed when the installation is launched Refer to Installation on Windows section to follow the same steps to complete installation Administrator C Windows system32 cmd exe Ci Users Administrator D Software Windows Setup exe eee T EELEE eg 1 Setup CyberPower PowerPanel Business Edition H IS Welcome to the CyberPower PowerPanel Business Edition Setup Wizard This will install CyberPower PowerPanel Business Edition on your computer The wizard will lead you step by step through the installation Click Next to continue or Cancel to exit Setup Accessing PowerPanel Business Edition The PowerPanel Business Edition web interface can be accessed following the directions below To access the web interface on a local computer select Start gt All Programs gt CyberPower PowerPanel Business Edition gt PowerPanel Business Edition Agent PowerPanel Business Edition Client or PowerPanel Business Edition Center in the Windows Desktop or enter the http localhost 3052 as the URL in the browser
33. rotating arrow causes to search the network to update the results If a UPS communicates with a computer that has been installed PowerPanel Business Edition Agent assign the IP address of the computer as the UPS network address This option appears when power connection is set up making computer connect to UPS directly When the power of a computer is configured to connect to an ATS two UPS addresses will appear to be assigned Any one of input source of ATS is being supplying power by a UPS the network address of UPS should be assigned An UPS address which is set blank indicates that the input source of ATS did not connect to an UPS 192 168 26 118 el Available Address MAC 00 00 15 00 45 F3 192 168 265 157 IP 192 168 26 65 192 168 26 68 Uptime 25 m 46 s 192 168 26 158 Name POUSOSWHYTISATNET 197 1628 26 76 Contact Administrator Location Server Room 192 155 25 93 Move the cursor over the target address to display details about the device The computer searches the device with the least uptime to be a default device after an installation One available outlet will be assigned to connect automatically with the computer If no outlet is available the first critical load outlet will be assigned to be used by a computer The uptime of the devices indicates the length of time that the device has been functioning When the computer scans the network the device with shortest uptime will be marked a yellow star icon You can p
34. supply battery power to connected equipment Frequency Upper Lower Bound When the utility frequency exceeds the threshold the UPS will supply battery power at a fixed frequency to the connected equipment 31 CyberPower Reliability Quality Value Detected Sensitivity When the UPS detects that utility voltage is out of range the UPS will switch to battery mode to protect the equipment plugged into the UPS Low sensitivity has a wider voltage range and the supplied power may vary more The UPS switches to battery mode rarely and also saves more battery power The power from a fuel generator may cause the UPS to switch to battery mode more frequently and low sensitivity is recommended High sensitivity allows the UPS to supply more stable power to equipment but switches to battery mode frequently Power Restore When a utility power failure occurs PowerPanel Business Edition software may order the computer to shut down and power off after the specified remaining runtime is met or if the battery capacity is low After the utility power is restored the UPS turns on automatically and supplies power to the computer If the computer BIOS is set to boot when power is restored the computer will automatically restart The following settings are used to configure the UPS restore behavior Automatic Restore When this option is enabled the UPS will restore output immediately when the utility power is restored When this opt
35. the firmware version on the RMCARD202 is earlier than 1 1 excluding 1 1 you should refer to SNMP SNMPv1 and SNMPv3 sections for the correct configurations SNMP The Client establishes communication and access device information via SNMPv1 and SNMPv3s Early UPS and PDU models only support SNMPv1 protocol and some newer models have supported SNMPv3 protocol User can choose the proper SNMP protocol according to the device SNMP Protocol User can determines which SNMP protocol to use over the network communication between Client and devices It is recommended to choose Both option because Client attempts on the correct SNMP protocol for device to interact 72 CyberPower Reliability Quality Value SNMPv1 SNMP Community The Client uses this community to authenticate communication between the PDU and UPS in order to access their information The default community is private By default the UPS PDU ATS use private as the community with write permission and public with read only permission The community used by the Client to access the UPS RMCARD PDU ATS must have a minimum of read permission for basic operation If the community has write permission the Client can complete some configuration tasks automatically If the Client cannot complete these tasks due to a permission limitation the following settings must be configured manually in the UPS RMCARD web or in the PDU web Note The community can be configured on the Network
36. the logs only related to this event will be displayed Max logs Indicates the maximum number of events that will be displayed Type Selects the event log whose type is system group or device Keywords Each event log whose detail contains this keyword will be filtered out Settings Please refer to Logs Settings section about how to configure Event Viewer settings Security Login Please refer to Security Login section about how to configure Account and Session settings Authentication The Center uses the secret phrase and SNMP protocol to secure and protect network communication between Agent Client and the devices The security settings on Security Authentication page in the Center must be configured If the Center establishes the communications with below devices refer to Secret Phrase section A computer running Agent and Client UPS RMCARD202 and higher version PDU whose mode is not PPU2Z0SW8RNET or PDU15SW8RNET If the Center doesn t interact with aforementioned application and devices refer to SNMP SNMPv1 and SNMPv3 sections for further details PowerPanel Secret Phrase Center can interact with Agent Client UPS RMCARD and PDU by using the secret phrase to create secure communication The default phrase is powerpanel encryption key The Secret Phrase can be configured on the Security Authentication page in the PowerPanel Applications or on the System Security page in the PDU and UPS RMCARD web The Secret Ph
37. window from the context menu of the correct outlet Click the Enabled option and Installed PPBE Client then enter the Client s IP address Click OK to attempt to establish communication After the process is successful the Name Location and Contact will be updated Attach New Generic Equipment 97 CyberPower Reliability Quality Value Example New generic equipment such as a printer or LCD monitor has been connected to UPS outlet 2 use the following steps to attach this new generic equipment Select Show Outlets from the context menu of the UPS to expand all outlets Select the Settings tab of the Details window from the context menu of the correct outlet Click the Enable option and fill in the Name Location and Contact fields Click OK to attach the generic equipment Move the Equipment If you reconnect existing equipment to another outlet or another device you should assign the equipment to the correct outlet with the following steps Select Move from the context menu of this equipment Choose the correct outlet and target device in the Move window Click OK to complete the operation Note A computer running Agent is only allowed to move to outlets on a single UPS In order for Agent to have sufficient time to complete a shutdown an Agent cannot be moved to NCL outlets Detach the Equipment When you unplug equipment from the UPS PDU ATS this equipment should be detached Uncheck the nstalled
38. 0 encoding UTF 8 standalone yes gt lt webServer gt lt httosMode gt ENABLE lt httpsMode gt lt httpsPort gt port_number lt httpsPort gt lt webServer gt lt webServer gt Change the port of the lt httpsPort gt and make sure that the port is not occupied by other services or applications Save the webserver xml file httpsNumber is numeric from 1 65535 Note The default port number is 53568 122 CyberPower Reliability Quality Value e Find the PowerPanel Business Edition service at the Control Panel Administrator Tools Services and restart the service in order to access through this new setting 11 The host name and IP address at the Agent s banner on the vMA of the VMware ESXi host displays Unknown Follow below steps to correct this condition Run the command sudo vi etc hosts with root permission Add the below snippet with the IP address and hostname 192 168 1 1 hostname Note IP address and host name can be inquired using the commands ifconfig and hostname Restart the service using the commands sudo service ppbed stop and sudo ppbed service start Login the page again The host name and IP address will be correct 12 My Client computer always shuts down hibernates on each time my system starts It may be caused by the following conditions Due io too short shutdown time or an unresolved problem a power event which causes system shutdown may
39. 12 39 PM Jul 18 2014 2 12 24 Pu Jul 18 2014 2 11 35 Eu Jul 18 2014 2 09 40 PM Jul 16 2014 2 09 37 PM There is not sufficient runtime for a complete shutdown even if the battery has fully recharged i Communicaton wth the device has resumed Local communication with the device has been los There is not sufficient runtime for a complete shutdown even if the battery has fully recharged Communication wih the device has resumed Caitration was infiated the battery runtime wil be evaluated There is not sufficient runtime for a complete shutdown even if the battery has fully recharged Communication wth the device has resumed i Utility power has been restored the battery has stopped supplying power Utiity power faure battery power wil be supped Utility power has been restored the battery has stopped supplying power Utility power faiure battery power will be suppbed Utiity power has been restored the battery has stopped supplying power Utility power failure battery power wil be supphed Utility power has been restored ne battery has stopped supplying power Utility power faure battery power wil be supplied UtikRy power has been restored the battery has stopped supplying power Utity power failure battery power wil be suppted Utity power has been restored the battery has stopped supplying power Utiity power faiure battery power wil be supped Utity power has been restored tne battery has stopped supplying power Logs Event Logs page
40. 5 min The setting for the Local communication lost event would be copied from the settings of the UPS is faulty event Event List The Event List displays power events The events displayed vary depending on whether they are listed in Agent or Client and which UPS PDU ATS is providing the events Battery capacity is critically low Battery capacity is critically low power could be lost immediately Local communication lost in a power event Communication with device has been lost during a power event Communication between the Agent and the UPS using the USB or serial cable has been lost during a power failure Batteries are not present Batteries are not present the UPS cannot provide battery power in this condition Available runtime is insufficient There is not sufficient runtime for a complete shutdown even if battery has fully recharged This event will occur if the UPS has insufficient runtime based off of the necessary shutdown time in the Event Action page for the Agent computer and all Client computers to shut down completely even if the batteries have fully charged An excessive load or long shutdown time may cause this event Reduce some UPS load or set a more accurate shutdown time to avoid this event occurrence Enters bypass mode Entering bypass mode battery power protection will no longer be provided Utility power failure Utility power failure battery power will be supplied Remaining runtime will be exhausted Remaining ru
41. 70 AA quest OS 32 MB Device Type What sort of device do you wish to add to your virtual machine Device Type USB Controller Ready to Complete eet fe erties 3 Parallel Port Choose the type of device you wish to add This device can be added to this Virtual Machine sab SCSI Device 129 CyberPower Gah Quality Value Ei IS will add a USB Controller click Next to add a USB Device b Add Hardware USB Controller Provides a 2 port USB controller that allows connecting and disconnecting USB devices Device Type USB Controller Ready to Complete Device Information The presence of a USB controller allows USB devices to be connected to the virtual machine The controller itself has no configurable settings lt Back ae Cancel J Select New USB Controller and click Add to add a USB device vSphere Management Assistan Hardware Options Resources Te l Show All Devices Hardware a Memory UI cPus E Video card CO VMCI device e SCSI controller 0 CO Hard diski Bi Network adapter 1 New USB Controller addi Present 12 MB 1 Video card Restricted LSI Logic Parallel Virtual Disk VM Network Virtual Machine Version 7 The presence of a virtual USB controller allows this virtual machine to connect to USB devices but the controller itself has no configurable options Host USB devices are connected to virtual machines ersistently in
42. 9 08 08 PM 2014 12 18 07 5254 PM 2014 12 18 07 10 55 PM 2014 12 18 07 08 12 PM 2014 12 18 06 41 35 PM 2014 12 18 06 35 36 PM 2014 12 18 06 33 38 PM 2014 12 18 05 3421 PM 2014 12 18 04 47 25 PM 2014 12 18 04 47 04 PM 145 gt A 2 Event i UPS RMCARD303 192 168 256 5975 battery has fully charged i POU PDU 15SWBFNET 192 1568 26 51 has no load output i ATS POU 1SMHVIEC 12AT 192 168 26 70 has no load output Redundant input source of ATS PDU 1SMHVIEC 12AT 192 168 26 70 is power faiture i UPS RMCARD303 192_ 168 26 59 s battery has fully charged UPSIPOUIOSWHVTISATNET 192 168 26 88 s utility power failure i UPS PDUI0SWHVT ISATNET 192 168 26 88 s battery has fully charged i UPS PDUS0SWHVT ISATNET 192 168 26 88 s battery has fully charged i UPSIPDUSOSWHVT ISATNET 192 168 26 88 s battery has fully charged i UPS PDOUIOSWHVT 19ATNET 192 168 265 8875 battery has fully charged i UPS PDUIJOSWHVT 19ATNET 192 168 26 88 s battery has fully charged i UPS POUIGSWHVT 1I9ATNET 192 168 26 88 s battery has fully charged i UPS POUSOSWHVT ISATNETG 192 168 26 88 s battery has fully charged i UPS PDUSO0SWHVT 19ATNET 192 168 26 88 s battery has fully charged i UPS PDUJOSWHVT I9ATNET 192 168 26 88 s battery has fully charged i UPS POUSOSWHVT ISATNET 192 168 26 88 s batery has fully charged i UPS PDU30SWHVT 1S9ATNET 192 168 26 88 s battery has fully charged UPS PDUS0SWHYT 19ATNET 192 168 26 88 s network communication h
43. Cy ber Power Reliability Quality Value PowerPanel Business Edition User s Manual Rev 20 2015 08 18 CyberPower Reliability Quality Value ELECTRONIC END USER LICENSE AGREEMENT FOR CYBERPOWER POWERPANEL BUSINESS EDITION NOTICE TO USER THIS IS A CONTRACT BY INSTALLING THIS SOFTWARE YOU ACCEPT ALL THE TERMS AND CONDITIONS OF THIS AGREEMENT The End User License Agreement and copyright of CyberPower PowerPanel Business Edition product and related explanatory materials Software are owned by its Cyber Power Systems USA Inc The term Software also shall include any upgrades modified versions or updates of the Software licensed to you by Cyber Power Systems USA Inc Please read this Agreement carefully At the end you will be asked to accept this agreement and continue to install or if you do not wish to accept this Agreement to decline this agreement in which case you will not be able to use the Software Upon your acceptance of this Agreement The Cyber Power Systems USA Inc grants to you a nonexclusive license to use the Software provided that you agree to the following 1 Use of the Software You may install the Software on a hard disk or other storage device install and use the Software on a file server for use on a network for the purposes of i permanent installation onto hard disks or other storage devices or ii use of the Software over such network and make backup copies of the Soft
44. ESX or ESXi to run virtual machines Hosts provide the CPU and memory resources that virtual machines use and give virtual machines access to storage and network connectivity You can add a virtual machine to a host by creating a new one or by deploying a virtual appliance The easiest way to add a virtual machine is to deploy a Virtual appliance A virtual appliance is a pre built virtual machine with an operating system and software already installed A new virtual machine will need an operating system installed on it such as Windows or Linux Click Browse to import the ppbeXXX_centos ovf extracted from the downloaded zip file Click Next to start a deployment task Select the source location OVF Template Details End User License Agreement Name and Location Deployment Configuration Disk Format Deploy from a file or URL hires m ng E walppbe 32_centos_bugfix ppbe232_centos ppbe232_1 e Enter a URL ates JE ELETE e E ETE j j ssible from your computer such as a local hard drive a network share or a CD DVD drive The OVF template detail is displayed Click Next to continue 16 CyberPower Reliability Quality Value G Deploy OVF Template OVF Template Details Verify OVF template details Source OVF Template Details Product Download size Size on disk Description Enter the name for the deployed virtual appliance This name should be unique within the inventory E Deploy OVF Te
45. Environment humidity is overdried The relative humidity is measured by the sensor violates the low threshold Principles for Client Firing Events If both power sources of the ATS which connects with Client can be provided power by two UPS the UPS event will be fired in the events of two power sources failure at the same time If there is one single or none UPS providing power to the ATS the event will be fired in case of power failure Note In Client events will be divided into categories according to its power connection Each event has the individual settings for each category 55 CyberPower Reliability Quality Value Notification Recipient The Agent and Client can send notifications to multiple recipients in various ways including Windows Alert Messages Instant Messages and Mobile phone text messages SMS The Notification Recipient page lists all recipients in the recipient list and displays all defined notifications and whether the notification is active Notification Recipient Active Sg Yes No Language English Recapient Name E mail Address Enabled ME Account Enabled WUM Account Enabled Computer Username Enabled Mobile Phone Number Enabled Active Days Mon V Tue Wed Thu Fri Sat 4 Sun Woring Rest Al Active Time OAN el GAN el On Duty Qtt Duty Al Cancel Ven Recent Active Recent Name E mail XMPP WLM Alert SMS Plan eeeessen eeenvee en se wm mmm Event Action Reci
46. ION_FAILURE LOST IN LOCAL Local communication lost LOST IN NETWORK Network communication lost FAULT GENERIC_FAULT UPS is faulty BYPASS FAN FAULT Bypass fan is faulty BYPASS FAULT Bypass is faulty MODULE_RECTIFIER FAULT Module rectifier is faulty MODULE_INVERTER_FAULT Module inverter is faulty MODULE_FAN_FAULT Module fan is faulty RUNTIME_INSUFFICIENT Available runtime is insufficient URGENT_COMMUNICATION _ FAILURE LOST IN LOCAL Local communication lost in a power event LOST_IN_NETWORK Network communication lost in a power event RUNTIME_WILL_EXHAUST Remaining runtime will be exhausted OUTPUT_WILL_STOP The output power is going to stop soon SHUTDOWN TIME Shutdown time is in INSUFFICIENT insufficient ALL_SOURCE_FAILURE Inputs both fail ATS doesn t switch input source CURRENT SOURCE FAILUR Switch to redundant input E source of ATS automatically REDUNDANT SOURCE FAIL Redundant input source of URE ATS is power failure ENV GENGOR LOST Environment sensor is no response ENV SENSOR_OVERHEAT Environment temperature is overheated ENV SENSOR _UNDERCOOL Environment temperature is undercooled ENV _SENSOR_OVERWET Environment humidity is over wet ENV _SENSOR_OVERDRY Environment humidity is overdried 1 This event only occurs for the Modular UPS in Agent This event only occurs for the PDU in Client 3 This event only occurs in Client 4 This EVENT variable must come with a E
47. Initiate the wizard by running the ppbe linux x86 sh command or double clicking ppbe linux x86 sh on 32 bit systems or by running the ppbe linux x86_64 sh command or double clicking ppbe linux x86_64 sh on 64 bit systems Note On Linux systems users may mount the CD by using the mount command Run mount t iso9660 dev cdrom mnt cdrom as a root user dev cdrom is the CD drive and mnt cdrom will be the mount point To install follow these steps Click the Next button to start an installation Setup CyberPower PowerPanel Business Edition Welcome to the CyberPower PowerPanel Business Edition Setup Wizard This will install CyberPower PowerPanel Business Edition on your computer It is recommended that you close all other applications before continuing Click Next to continue or Cancel to exit Setup Next gt Cancel Accept the license agreement 11 CyberPower Reliability Quality Value Setup CyberPower PowerPanel Business Edition License Agreement Please read the following important information before continuing Please read the following License Agreement You must accept the terms of this agreement before continuing with the installation ELECTRONIC END USER LICENSE AGREEMENT FOR CYBERPOWER POWERPANEL BUSINESS EDITION NOTICE TO USER THIS IS A CONTRACT BY INSTALLING THIS SOFTWARE YOU ACCEPT ALL THE TERMS AND CONDITIONS OF THIS accept the agreement O Ido not accept
48. MP settings Open the Network Trap Notification page on the UPS PDU ATS web and the Security Authentication page on the Client Confirm that the IP address of the Client can be found on the Network Trap Notification page of the UPS PDU ATS web If the IP address can be searched skip the step 3 lf the IP address of the Client could not be found click the Trap Receiver shortcut of the Network Trap Notification page to enter the Trap Configuration page Enter the required data to add a new trap receiver lf the IP address of the Client could be found verify the SNMP settings are matched How do I determine that if my computer is using hibernation or not If the operating system is Windows 2000 Windows XP or Windows Server 2003 please follow the below steps to enable the hibernation Open Power Options in the Control Panel Go to Start gt Control Panel gt Power Options Click the Hibernate tab and then select the Enable hibernate support option Click the OK button to close the Power Options dialog box The hibernation has been enabled If the tab is not available your computer doesn t support this hibernation If the operating system is Windows Vista Windows 7 Windows Server 2008 Windows 8 or Windows Server 2012 please follow the below steps to enable the hibernation Open the Command Prompt dialog box Use the command powercfg exe hibernate on to enable the hibernation Which series does my UPS model belong
49. NET12 RMCARD303 i Bower Cycle directly without seugneced delay OK Cancel A confirmation window of a bulk power cycle operation Note If a group contains the UPS systems which has connected with PDU units a power cycle or a power off to the selected group will result in computers shutdown on the PDU units Battery Test Only UPS units can perform a battery test Click Battery Test from the context menu of the selected group All UPS units in that group will be listed in the confirmation window Click OK to initiate the battery test on all selected UPS units Mute Click Mute from the context menu to mute the alarm Alarm Click Alarm from the context menu to enable or disable the UPS alarm IT Equipment Details IT equipment is computers which have PowerPanel Agent or Client installed or generic equipment that has power supplied by a UPS PDU ATS Center provides the following options to attach new equipment to an outlet attach existing equipment from another outlet or another device detach unused equipment and rename equipment Attach New Computer When a new computer running Agent or Client is plugged into a UPS PDU ATS it should be assigned to the correct outlet Example A computer running Client connects to outlet 1 on a PDU The Client should be assigned to an outlet by the following steps select Show Outlets item from the context menu of the PDU to expand all outlets Select the Settings tab in the Detai s
50. RAM recommended minimum more memory generally improves responsiveness Minimum of 150 MB of free space of hard disk Serial port or USB port Required by the Agent Network interface Operating System PowerPanel Business Edition software can be installed on the following operation systems 32 Bit Versions WR Windows 10 Windows 8 Windows 7 Windows Server 2008 Windows Server 2008 R2 Windows Vista Windows Server 2003 Windows Server 2003 R2 64 Bit Versions Windows Server 2012 Windows Server 2012 R2 Windows Hyper V Server 2012 Windows Hyper V Server 2012 R2 Windows 10 Windows 8 Windows 7 m Windows Server 2008 Windows XP Windows 2000 Citrix XenServer 5 or later Red Hat Enterprise 5 1 Fedora 7 or later SUSE 10 1 or later Debian 5 1 or later Ubuntu 9 10 or later Windows Server 2008 R2 Windows Vista Windows Server 2003 Windows Server 2003 R2 Windows XP Ubuntu 11 04 or later Open SUSE 11 4 or later VMware ESX ESXi 4 or later Note Because of the abundance of different Linux builds not all builds are tested with PowerPanel Business Edition but most builds will be able to run the program Web Browser PowerPanel Business Edition software is accessed using a web browser and is compatible with the following browsers Microsoft Internet Explorer 7 or above CyberPower Reliability Quality Value Firefox 2 0 or above Google Chrome Konqueror Installation Installati
51. S JP SS Remote Management Und Ba ze L n art Ch Tl p hong ge k em ent Chent Client Client D P a i ka p gt omiguration A ontiguration H Configuration L Configuration D Center E la Nutr l i e PowerPanel Business Edition structure A UPS with a remote management card has the ability to communicate with multiple computers which have Client installed and are on the same network and relay the UPS status to each Client In the event of a power failure each Client will request the hosted computer to shut down following notifications from the UPS Refer to Configuration B of the PowerPanel Business Edition structure illustration The Client also has the ability to communicate with a PDU Each computer powered by a PDU can utilize the Client for protection and control When a PDU outlet supplying power to a computer running Client is going to CyberPower Reliability Quality Value be switched off the Client will perform a shutdown prior to switching off the power Refer to Configuration C of the PowerPanel Business Edition structure illustration Agent Aside from the primary function of shutting systems down in the event of an outage the Agent also provides the following functions Unattended shutdown in response to various power conditions User notification of power conditions Flexible configuration of actions for each event and notifications via E mail Instant Message and SMS
52. S 15 4 CONTRACT BY INSTALLING THIS SOFTWARE YOU ACCEPT ALL THE TERMS AND CONDITIONS OF THIS 4GREEMENT The End User License Agreement and copyright of PowerPanel r Business Edition product and related explanatory materials Software are owned by its originated company The term Software also shall include any upgrades modified versions or updates of the Software licensed to you by I do not accept the agreement Choose the component If one single computer is connected to the UPS directly via a USB or serial connection Agent should be installed If the computer is powered by a UPS already connected to an Agent has a remote management card installed or is connected to a PDU Client should be installed If the administrator requires simultaneous monitoring and access to multiple UPS PDU ATSs equipment and computers on a local network Center should be installed Note Agent Client and Center cannot be installed on the same computer P Setup CyberPower PowerPanel Business Edition Select Components Which components should be installed Select the components you wank to install clear the components you do not want to install Click Next when vou are ready to continue TI Center C d Client TT cr Agent Choose the destination directory CyberPower Reliability Quality Value Setup CyberPower PowerPanel Business Edition Seles Select Destination Directory Where should CyberPower PowerPanel Business Edit
53. Sphere Client Select the VMware host Click Configuration Select the target datastore from the right hand side Right click the target datastore and click Browse Datastore Click Upload button on the toolbar and select the file you want to upload Click OK button to continue with the upload files into the target datastore How do upgrade the virtual hardware version of VMA For vMA running on ESXi 5 x it is recommended to upgrade the virtual hardware to version 8 To upgrade the virtual hardware version of VMA as below steps Start the vSphere Client and power off the target vMA Right click the virtual machine and select the Upgrade Virtual Hardware menu option to upgrade virtual hardware Power Guest Snapshot Open Console Edit Settings Upgrade Virtual Hardware Add Permission Ctrl P Report Performance Rename Open in New Window Ctrl Alt N Remove trom Inventory Delete tram Disk Click Yes to continue with the vMA upgrade Confirm irtual Machine Upgrade x l This operation will cause the virtual hardware your guest operating system runs onto change It is an irreversible operation that will make your virtual machine incompatible with earlier versions of VMware software products Ik is strongly recommended that you make a backup copy of your disks before proceeding re vou sure you Wank to upgrade your configuration Power on the vMA to make the changes take effect 20 How do I r
54. These actions include notification command execution and computer shutdown If a Client establishes with a PDU which is connected to a UPS the Client can generate actions in response to events from the PDU or the UPS Events When an event occurs PowerPanel Business Edition software can notify administrators execute a command and initiate a computer shutdown sequence The Event Action Events page lists events and the action settings for the events The severity of each event is marked by a symbol Severe level indicates users must be alerted and the computer shut down to avoid an improper shutdown Warning level indicates a warning and users should be notified when it occurs If a warning condition persists a system shutdown may be imminent Information level 1 indicates the state of the UPS or that the utility power condition has changed 48 CyberPower Reliability Quality Value Ho Event infibated UPS is taulty instant f Local communication lost in a power event ingtant Remaining runtime will be exhausted instant System is overheated instant UDIY power failure ingiant Outpul is overloaded instant Batteries are not present instant Local communication lost natant Communication cannot estadlish instant Avadable runtime ts insuMcient instant i Shuldown initiated instant i A schedule has initisted i Battery test is processing i Calibration intiated i Output voltage is being bo
55. VENT_CONDITION variable This event only occurs for the ATS in Client This event only occurs for the environment sensor for UPS PDU ATS in Client Shutdown CyberPower Reliability Quality Value Initiate a shutdown sequence when an event occurs A shutdown sequence is only initiated by events which are of severe level and warning level type As Initiated Determines whether to request the computer to be shut down and the delay before initiating the shutdown sequence The shutdown will be canceled if the event is cleared during this delay time The minimum delay time to initiate shut down is based on the time set for the execution of the other actions to complete This includes the notify delay time command delay time and command execution time This feature is used to apply identical settings to the particular event within the same category Severe Warning and Information Once the As field of one event have been assigned the settings of this event will use the assigned event s settings The settings of this event will match with an assigned event s Notify Command Shutdown Ho Event Initiated Repeat Initiated Duration File Initiated UPS is faulty Inactive Inactive 15ec 5 min 2 Local communication lostin a power eventinstant Inactive Inactive 3 Remaining runtime will be exhausted Instant Inactive Inactive 15ec 10 sec 4 System is overheated Instant Inactive Inactive 15ec
56. _address 3052 in the address filed of the web browser from a remote computer On Linux you only enter the URL http localhost 3052 the address field of the web browser from a remote computer for a local access You can also enter the URL http nhosted_computer_IP_address 3052 in the address filed of the web browser from a remote computer Which operation systems are supported by PowerPanel Business Edition software And which browser supports them 125 CyberPower Reliability Quality Value Refer to the Getting Started Prerequisites for more details 4 My Client computer connects to a PDU How do I ensure the IP address assigned on the Power Configuration page matches the actual PDU IP address How do I ensure the outlet configured on the Power Configuration page matches with the actual connection Click the Identify button at the Outlet block screen The PDU LCD screen will blink the outlet number on the connected PDU The PDU IP address can be verified by pressing the select button on the PDU until the IP address displays on the LCD 5 What is the difference of the NCL Non Critical Load outlet and CL Critical Load outlet Which equipment should connect to NCL outlet or CL outlets The NCL outlets are only available on specific UPS models and are designed to be powered off early to maximize the battery runtime for the CL outlets Non critical equipment such as redundant equipment monitors or other non c
57. a new tab which displays Center web page Specify the product type and enter the necessary data Press the OK button to add the infrastructure Remove an Infrastructure Highlight the topmost vCenter server or ESXi host you wish to remove and select Remove in the context menu The Rename an Infrastructure window will display Click OK to apply the removal lf the plugin has been installed in vCenter server the plugin will also be uninstalled during removal If the infrastructure has been connected with the power device the power source will also detach the infrastructure Service Infrastructure Details 108 CyberPower Reliability Quality Value Summary The Summary tab provides an overview of the infrastructure information Virtual Machine Indicates the selected infrastructure is virtual machines E Name The name of the selected virtual machine m Status Displays the present status of the selected virtual machine m Address The IP address of the virtual machine when the virtual machine is running VMware ESXi Host Indicates the selected infrastructure is an ESXi host It may be the ESXi host to which the selected virtual machine belongs m Name The name of the selected ESXi host Address The IP address of the ESXi host Status Displays the present status of the ESXi host Type Specifies the node is ESX or ESXi host VM Amount The amount of virtual machines on the target ESXi host VMware vCente
58. al power consumption of today this month this year and entire system in the System Energy block Note Internet explorer 6 and lower versions cannot support the graphic chart The Internet explorer should be upgraded to the higher version which is capable of rendering the graphic charts Settings Energy Alerts All Energy 665000 0 100000 0 Default Energy High Threshold Low ihresmoid Energy Consumption Settings page Center has capability of reminding administrators of being violated in power consumption The Setting page allows administrators to configure thresholds When power consumption violates thresholds Center will be aware of the violation and warn administrators System Energy set the thresholds for the Center system High Threshold When the whole power consumption of the system exceeds this threshold the tip System consumption is too high will show on the banner of the Power Equipment page 112 CyberPower Reliability Quality Value Low Threshold When the whole power consumption of the system violates this threshold the tip System consumption is too low Will show at the banner of the Power Equipment page Default Energy Set the default thresholds for each group or power equipment When the thresholds of Excess Consumption Alert have never been set Center will use these thresholds as the default settings o High Threshold When the power consumption which the gro
59. alibration initiated Calibration was initiated the battery runtime will be evaluated A schedule has initiated A schedule has initiated the system may be shutdown Battery is fully charged Battery has fully charged The capacity of battery is full Shutdown initiated Shutdown process initiated A shutdown process has initiated and the system will shut down or hibernate ECO is active The UPS is in ECO mode The UPS switches to bypass and starts to monitor whether the utility voltage and utility frequency is in range of the thresholds The battery has been exhausted Battery is exhausted and UPS stops the output EPO is active EPO was activated the UPS output power was turned off immediately EPO Emergency power off is intended to allow the administrator to have a method of immediately turning off output power from the UPS Bypass power is failure The condition of bypass power is out of regular range or blackout In this condition the UPS will shut down and never enter the bypass mode once UPS is faulty Inverter capacity insufficient UPS did not have enough capacity of inverter s power to enter line mode from bypass mode Power redundancy is not enough The quantity of UPS module has not enough to be redundancy completely and the fault tolerant ability was reduce or lost completely Power redundancy provides additional protection against failures of UPS modules If one module has a fault the other module will take over This event will occ
60. alk google com 2 9 Google Talk service name gmail com Service port 52272 Account ppbe_user Password O Apply Verity XMPP Instant Messaging service To use XMPP Instant Messaging users must provide a unique XMPP Instant Messaging Service account as a sender and assign different account as a receiver on Event Action Notification Recipient page Activate Specifies whether the Agent Client XMPP Instant Messaging service to notification is active or inactive Service address Sets the XMPP server address according to your XMPP Server configuration Select Google Talk to use predefined settings for Google Talk service Service name Sets the service name on an XMPP Instant Messaging server This option is usually not required Contact the systems administrator of the server for the service name if required Service port The port number which the XMPP Instant Messaging server will use Account Sets the account to access the XMPP Instant Messaging server Password Sets the password for the account Messenger Service Terminal Services Remote Desktop Services 60 CyberPower Reliability Quality Value Terminal Services Activate Yes No Apply Messenger service Messenger Service Terminal Services Remote Desktop Service only works on Windows platforms Options are explained below Activate Specify whether to use this service to send a notification to recipients If the service is not started clicking Yes optio
61. as failed i UPS PDUSOSWHVT 19ATNET 192 168 26 88 s batery has fully charged i UPS PDUSOSWHVT 19ATNET 192 168 26 88 s battery has fully charged Environment sensor of UPS PDU30SWHVT 1SATNET 192 168 26 88 has no respon Displaying logs 1 100 0f498 Clean Save Logs Event Logs page Filter The following filter options can be utilized by expanding Filter panel Once the configuration of the filter pane is configured the logs will be requested and displayed Filter Display all a Days 10 01 2014 BL 01 30 2015 All Thisday Last day Previousday Next day That dau Time 09 00 AM e 05 00 PM All Duty On Duty Off Weekday Sun Mon Tue Wed Thu i Fri Sat All Working Rest Severity d Severe Warning lt Information Category 4 System Event Power Event All Events ly Max logs 500 ix Type Ups be Keyword RMCARD Filter pane on Logs Event page Days Selects the day s for the events to be displayed The dropdown menus next to the Days setting can be used for additional preconfigured filters Time Selects the time range for the events Weekday Choose the days of the event occurrence 117 CyberPower Reliability Quality Value Severity amp Category The events can be filtered by category and severity The events can be further divided by Power Event and System Event categories and choosing the specific event When any event option is selected from the event list
62. asted i Output voltage ts being bucked i Battery is fully charged Notrfy Command Shutdown Repeat initiated Duration He Initiated inachve inactive inactive inactive inactye inactive inactive inactive inactive inactive inachye inacive inacthye inactive She inactive inactive inactive inactive Cu af live inactive Event Action Events page in the Agent After selecting an event the event will become configurable Configure all of the action settings for the selected event and apply to save the settings 5 Output is overloaded Instant Inactive Inactive lt 1 Sec Inactive Instant Inactive we Inactve 1 sec w Inactive Ww T Batteries are not present Instant Inactive Inactive lt Sec Inactive The clicked event item will be configurable Use these parameters to configure actions for individual events Notify The administrator can be notified when an event occurs See Event Action Notification Recipient page for more details about the notification methods and recipient assignment Command A command will be executed when an event occurs Initiated Determines whether to send a notification or not and sets the notification delay If the event is cleared within the notification delay the notification of the occurrence and the event cleared notification will not be sent Repeat Determines whether to send one additional notification after the initial notification Only events which are
63. attended shutdowns scheduled shutdowns and notifications for computers powered by the UPS Uninterruptible Power Supply PDU Power Distribution Unit or the ATS Automatic Transfer Switch PowerPanel Business Edition software consists of Agent Client and Center The Agent monitors and configures the UPS through the USB or serial connection It logs the UPS status and power events and generates action in response to events The Client establishes communication with the Agent UPS RMCARD and PDU and generates actions according to notifications from the UPS PDU ATS when a power event occurs The Center simultaneously monitors and controls multiple UPS PDU ATSs and computers which have Agent or Client installed via the local network It also logs events and results about commands for power management The Agent should be installed on a single computer connected to the UPS with a USB or serial connection The Agent controls the UPS and establishes communication with the Client if the UPS has no remote management card The Agent relays the UPS state to each Client and the Client performs actions based on the notifications Each computer powered by the UPS can be protected and controlled using the Client In the event of power failure the Agent will shut down the hosted computer and request the Client computers to shut down prior to the UPS shutting down Refer to Configuration A of the PowerPanel Business Edition structure illustration UPS UP
64. ay be a computer or powered equipment Computer This computer is the VMware vCenter host Computer This computer is the VMware ESXi server A node also provides a column to indicate what the current state is and what power events have occurred A UPS node column can display power events such as Utility power failure or Runtime is insufficient and a PDU node column can display power events such as nput is low load or Input is overload Each node provides a column to describe what the current status is and what operation is processing A computer node displays whether it is going to be shut down and a generic equipment node displays whether it is going to be powered off in event of the device it is plugged into turning off Group Management Multiple computers and generic equipment can be managed by grouping them All computers and generic equipment can be added to a group and moved between groups Add Group 101 CyberPower Reliability Quality Value Users can click Add Group on the toolbar to create a new group La Add Group button on toolbar F LA Or click the Add Group item to create a new sub group from the context menu of a selected group Enter the new group name and click OK to add a new group You may have sub groups but a duplicate name is not allowed Move Group Select the group you wish to move and select Move in the context menu The Move Group window will display select the target group
65. bility Quality Value Note Some computers require manual booting when a UPS or a PDU powers on To change this set the computers BIOS to boot when power is restored Power On EN oh PDULSSWSFNETI2 will power on Are you sure to wf perfrom this operation Power on directly without sequenced delay OK Cancel A confirmation window of a PDU power on operation Power Cycle Initiates a Power Cycle on the UPS PDU ATS This will turn the UPS PDU ATS off then back on or vice versa Decide whether to initiate an immediate or a sequenced power cycle and click OK to begin A sequenced power cycle will cause computers connected to the UPS PDU ATS that have Agent or Client installed to shut down prior to the power cycle Note An immediate power cycle off will likely result in connected computers losing power Power Cycle EN ch PDULSSWSFNET1L2 will power cycle Are you sure GZ to perfrom this operation Power cycle directly without sequenced delay OK Cancel A confirmation window of a PDU power cycle operation Note If a PDU is connected to a UPS a power off or a power cycle to the UPS may also cause all computers on this PDU to shutdown Battery Test Click Battery Test from the context menu and the UPS will initiate a battery test Mute Click Mute from the context menu to mute the alarm Alarm Click Alarm from the context menu to enable or disable the UPS alarm Preferred Source Click Preferred Source from the context menu
66. cation Contact IP Address Ce DVRDSO Rack A Torre Tel 4321 192 168 24 59 Hosted computer 2 Le ERP Server Rack A Ray Tel 3412 192 168 24 64 4 Es Rounter A Rack A Billy Tel 1205 2 Ss Fan Controller Rack A Thomas Tel 1234 6 T B Client computer is printed in gray when the communication is not established The details in list are described as following Indicates which power outlet of the UPS or PDU is supplying power to the connected equipment Bank The bank type of the power outlet on the UPS e g NCL CL or Surge Name The name of the power equipment Location Where the power equipment is located Contact Who to contact about this power equipment IP Address The IP address of the computer that installed PowerPanel Business edition Client software In UPS tab a PDU with network function also shows its own IP address IP Address Available Address 192 168 24 16 a 192 166 244 64 192 166 24 240 Agent searches all Clients on local network EnergyWise Cisco EnergyWise technology allows Cisco switch to discover Cisco EnergyWise controllable devices keep track of the power use and take actions to reduce the power consumption The EnergyWise page allows users to configure the connection details with Cisco switch and manipulate the device as endpoints in the children list CyberPower Reliability Quality Value EnergyWise el Configure Version 1 2 0 Access Port 43440 Doam
67. ce The communication with Power Device has been lost The Client cannot establish communication with the UPS PDU ATS on the network or established communication has been interrupted Network communication lost with UPS in a power event The communication with UPS has been lost after a power event occurred When the utility power becomes abnormal and the UPS is using the battery to supply power loss of network communication between the Client and the UPS causes the Client to generate a critical priority event because it cannot respond to changes in the status of utility and battery power More events are available for a PDU in Client 04 CyberPower Reliability Quality Value Input is near overload A PDU is near an overload condition The load level is near the maximum safe load for the PDU Input is overloaded A PDU is in an overload condition The maximum safe load has been exceeded and the PDU is in an overload condition Shutdown time is insufficient System shutdown time is insufficient After communication with the PDU is established and the outlet assignment is set up the Client will detect whether the connected outlet has sufficient time to allow for a shutdown A sufficient shutdown time for the Client computer requires at least the sum of the Necessary shutdown time option and shutdown delay time as configured in the The output power is going to stop soon event More events are available for an ATS in Client
68. cture will be moved to another outlet or another UPS Only ESXi hosts can be set power protection In order to make sure that the infrastructure can be protected you should connect the infrastructure to the target UPS by assigning the UPS outlet When the Device setting is set blank this indicates that the infrastructure will be disconnected the power from the target UPS outlet In order to make sure that vCenter servers can be protected you should do following steps by the according deployment Ifthe vCenter server is a virtual appliance which has been deployed on the ESXi host the ESXi host should be also added to the Service Infrastructure page Connect the ESXi host with the UPS Ifthe vCenter server is running on a standalone Windows system it is recommended to install Agent or Client to get the power protection Note The infrastructure can be only allowed to set its power to UPS Event Action When an ESXi host has been configured the power source properly in the aforementioned section Center can send the notification to the administrator and initiate a shutdown sequence if the event occurs The Event Action tab lists all events and allows users to configure the shutdown delay time for each event Each event in the Event Action tab will use the identical Shutdown for Infrastructure setting to the according event in the Event Action Events page When users change the shutdown delay time the identical setting of the accord
69. d 0 UPS 12 PDU 11 Summary tab of Details Each group provides the statistics of all UPS PDU ATS from the Summary tab of Details and includes the following summary information Group Name A name of the selected group Statistics Indicates statistics about the operating conditions of the UPS PDU ATS Normal Indicates a UPS PDU ATS which is normal Severe Indicates a UPS PDU ATS with severe level power events such as Runtime is insufficient Warning Indicates a UPS PDU ATS with warning level power events such as Utility power failure Lost Indicates a UPS PDU ATS which has lost communication with Center Type Indicates the statistics of UPS PDU ATS Group Operations some or all devices in a group can have the following commands issued to them Computers on Outlets Shutdown Restart Select Shutdown or Restart from the context menu of the selected group and a pop up window will appear Pick the computers to shutdown or restart and click X on those you wish to remove from the list Click OK to initiate the shutdown or restart Note If a group contains the UPS systems which have connected with PDU units shutting down the selected group may cause the computers shutdown on these PDU units 95 CyberPower Reliability Quality Value Power Control Power Off Click Power Off and a confirmation window will appear Pick the UPS PDU ATS from the list and decide whether to perform
70. de section to follow the same steps to complete installation The installer requires root permission to initiate the installation procedure Mount CD by running mount t iso9660 dev cdrom mnt cdrom as a root user dev cdrom is the CD drive and mnt cdrom will be the mount point Browse the CD drive and find the installer in the Software Linux folder Initiate an installation procedure by running the ppbe linux x86_64 sh command CyberPower Reliability Quality Value Before installing Agent with the USB or serial connection make sure that the platform running the Agent supports USB or serial connection VMware ESXi 4 1 and later versions support a USB device to be passed through from an ESXi host to vMA Note In order to make sure that Agent on vMA of the ESXi host can establish communication with UPS through USB connection you should upgrade virtual hardware to the latest version Refer to How do upgrade virtual hardware version of vMA of FAQ chapter from PowerPanel Business Edition User Manual to know how to upgrade Note In order to allow the interactions between physical and virtual machines VMware tools have to be installed on each virtual machine Refer to VMware ESXi Server documentation for further information about VMware Tools Installation on ESX Installation must be launched in the Service Console aka Console Operation System To initiate the installation procedure on VMware ESX also requires root permissio
71. des Follow up and Fixed In the Follow up mode the UPS supplies power based off of the utility frequency If utility frequency varies and is out of tolerance the UPS supplies battery power with a fixed frequency to avoid supplying the connected equipment an improper frequency The fixed frequency depends on the utility frequency detected as the UPS Is powering up In Fixed mode the UPS supplies power at a fixed frequency with no regard to utility frequency When the input frequency is unstable such as with power supplied by generators set the UPS to fixed mode to supply power with a stable frequency The UPS can be set to fixed mode if the equipment needs a different frequency from the utility power For example the equipment is rated at 50 Hz but utility frequency is at 60 Hz Follow up Tolerance Sets the acceptable range of the output frequency on the Follow up mode Fixed Frequency Sets the fixed value of the output frequency on the Fixed mode Caution The wrong frequency settings may damage the connected equipment Make sure the selected frequency is correct for the connected equipment An alert warning message will remind you of the following conditions m The frequency mode has changed from the Follow up mode to the Fixed mode and the fixed frequency is not equal to the utility frequency m The frequency mode is Fixed mode and the fixed frequency is going to be changed ECO Mode The UPS will enter bypass mode according to the utili
72. dition Center Management Power Equipment Power Equipment page has the following capabilities in Center Monitor status and events from a connected UPS PDU ATS to shut down or a reboot Manage grouped UPS PDU ATSs Power Equipment Management di Server Room A RMCARD205 F Battery needs replacement NCL bank 1 2 have turned on E RMCARD205 NCL bank 1 2 have turned on Normal 3 RMCARD205 NCL bank has turned on Normal 4 _ Server Room B PDU20SWVT24FNET Normal 4 i Server Room C PDU15SWV16FNET Inputis overloaded 1 PR2200LCDRTXL2U Battery has fully charged Normal RMCARD303 Normal Power Equipment page Toolbar Issue commands to the UPS PDU ATSs such as a power off power cycle or power restore Request that the UPS perform a battery test sound its alarm or mute the audible alarms owh 120 0 V 64 0 E 120 0 V E 1h 53m 0 0W 120 0 V 99 0 By 120 0V i 2h 39m Fo 0 0W E 105 0 V 100 0 T 1190V 3h 59m D DA 493Wh 6 0A i 570 0W Q 15Wh 0 0A D Owi 105 3 V 100 10 E 1053 V El An 2m O 520w Si 105 5V 100 0 115 0V 1h 43m O o 0w Manage equipment and computers which are powered by UPS units and PDUs and order connected computers 508wh 90 2 Q o 5 Retesh The Toolbar provides information about the status of monitored devices and options to expand add group or device Toolbar of Power Equipment page These three buttons will allow users
73. down process The computer will shut down or enter hibernation Battery has fully charged Battery has fully charged The capacity of battery is full Battery capacity is critically low Battery capacity is critically low power could be lost immediately 114 CyberPower Reliability Quality Value An outlet on a UPS has turned on A UPS outlet has been turned on The outlet can afford the power to its connected equipment PDU Network communication lost Center cannot establish communication with PDU on the network or established network communication has been interrupted Input is near overload A PDU is near an overload condition The load level is near the safe load threshold for the PDU Input is overload A PDU is in an overload condition The safe load threshold has been exceeded Power consumption is too high Power the specific PDU consumes has been exceeded the high threshold Power consumption is too low Power the specific PDU consumes has been violated the low threshold Shutdown initiated A computer which connects with PDU initiated the shutdown process The computer will shut down or enter hibernation ATS Network communication lost Center cannot establish communication with ATS on the network or established network communication has been interrupted ATS is faulty UPS has malfunctioned in internal Both input sources are power failure ATS stays in current one ATS doesn t switch the source due t
74. dundancy This power redundancy can provide the fault tolerant protection against failures of equivalent UPS modules UPS should avoid exceeding output load from whom deducted the power redundancy otherwise UPS cannot afford the equivalent fault tolerant protection as user s desire NCL Outlet NCL stands for Non Critical Load Under the following conditions the UPS will turn off the NCL outlet to conserve battery power and maximize battery runtime for the remaining outlets Turn Off Threshold When supplying battery power the UPS will power off this NCL outlet if the remaining battery capacity is lower than this threshold Turn Off Delay When supplying battery power the UPS will power off this NCL outlet after this delay time is met Turn On Delay When the utility power is restored the UPS will restore the output of this NCL outlet after the delay time is met This prevents excessive power consumption caused by all the connected equipment starting at the same time Diagnostics The UPS Diagnostics page provides the ability to verify that the UPS can supply adequate battery runtime for the connected computers to shutdown properly Perform a complete runtime calibration to ensure an accurate estimate of the runtime for the connected load The buzzer can be tested to ensure that the UPS can issue an alarm and that the indicator lights will display properly if requested by the UPS 35 CyberPower Reliability Quality Value
75. e Verify the network configuration in the device is correct Use the Power Device Network Utility tool to configure the device network configuration Verify the settings on the Security Authentication page are correct and match the settings of the UPS PDU ATS See Security Authentication for more details Verify the port on the Security Network page is matched if establishing communication with Agent Check the network status of the UPS PDU ATS and Clients Verify firewall settings Port 3052 UDP TCP port 53568 TCP port 162 UDP and port 53566 UDP should be unblocked The Client communicates with UPS PDU ATS and Agents using these ports 4 The battery test failed Replace the batteries if the batteries have used over 3 years Contact CyberPower for assistance and replace the batteries if the battery test still fails 5 The PowerPanel Business Edition installation failed lf the installation file is from CyberPower web site it may have downloaded incompletely or become corrupt Download the installation file again 6 I failed to extend the off delay time of Necessary shutdown time option The communities on the Security Authentication page in the Client and on the Network Access of Control page in the PDU may be not matched Confirm that the communities with the write permission are matched The Client may use the community without write permission to access the PDU Please promote the permission of the community wh
76. e server We recommend that you close this webpage and do not continue to this website Click here to close this webpage DI Continue to this website not recommended Gei More information Internet Explorer displays that the security certification is not trusted Mozilla Firefox At first click I Understand the Risks item to expand the content and click Add Exception bution to continue the next step CyberPower Reliability Quality Value This Connection is Untrusted You have asked Firefox to connect securely to 127 0 0 1 8443 but we can t confirm that your connection is secure Normally when you try to connect securely sites will present trusted identification to prove that you are going to the right place However this site s identity can t be verified What Should I Do If you usually connect to this site without problems this error could mean that someone is trying to impersonate the site and you shouldn t continue Get me out of here Technical Details I Understand the Risks If you understand what s going on you can tell Firefox to start trusting this site s identification Even if you trust the site this error could mean that someone is tampering with your connection Don t add an exception unless you know there s a good reason why this site doesn t use trusted identification Add Exception Firefox displays that the security certification is not trusted Second select Permanent
77. e PDU to ensure that the community must match SNMPv3 The Center will use the below SNMPvs8 settings to interact with a secure device These settings can be configured on the Security Authentication page of Center and on the Network Service SNMPv3 Service page of the UPS RMCARD PDU ATS web These settings must be matched one User Name Specifies a username match for protocol Authentication Protocol Sets the protocol to be used for authenticating the network communication between the Client and devices Authentication Key Sets the authentication key which is used for the aforementioned authentication protocol Privacy Protocol Sets the privacy protocol to be used for encrypting data during transmission between the Client and devices Privacy Key Sets the privacy key to encrypt data for the aforementioned privacy protocol Network Please refer to Security Network section about how to configure Network settings Help 119 CyberPower Reliability Quality Value Content Please refer to Help Content section about further details About Please refer to Help About section about further details Logout The Logout page allows users to log the user out of the web interface The user will be asked to assure whether to log out and users can log out web by clicking the Logout buiton Technical Support Troubleshooting 1 cannot access the PowerPanel Business Edition web interface after complete instal
78. e Schedule Shutdown page manages scheduled shutdowns and lists all configured schedules Each schedule row displays the details of when the schedule will take effect and when to perform it The time displayed at the upper right corner is the local time of the hosted computer If you are connected to a remote Agent this time may be different from the time on your computer Scheduled Shutdown Active Yes No Bank Ail e Frequency Once v Shutdown Time 2011 ip in minute Restore Yes 2011 Comment New Schedule Active Shutdown Time Restore Time Frequency Lomment 2009 10 19 06 29 PM force shutdown for pow Schedule page Create schedule Select the New Schedule shortcut to have the blank fields or use the data of the selected schedule Enter all required data and click Add to add a new schedule Modify the schedule Select the schedule you wish to modify After entering the new data click the Apply button to apply the schedule modification CyberPower Reliability Quality Value Remove the schedule Select the schedule to remove from the schedule list and click the Remove button to complete the schedule deletion The schedule detailed settings are explained below Active Choose Yes to activate this schedule effective If No is selected the schedule will be ignored Bank There are two conditions for this option Power off the output completely When users choose the Master Power option a
79. e direction of energy flow The portion of power flow remaining after being averaged over a complete AC waveform is the real power that is energy that can be used to do work On the other hand the portion of power flow that is temporarily stored in the form of magnetic or electric fields due to inductive and capacitive network elements and then returned to source is known as reactive power Apparent Power The product of the current and voltage of the circuit Power Factor The radio of the active power flowing to the load to the apparent power in the circuit In an electric power systems a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred NCL Outlet Displays the present status of the NCL outlet WR On This outlet is turned on and supplying power to the connected equipment Off This outlet is turned off and is not supplying power to the connected equipment WH Pending On This outlet is going to turn on following an action such as a scheduled turn on H Pending Off This outlet is going to turn off following an action such as a scheduled turn off Battery Status Displays the present status of the battery packs Fully Charged The batteries are at 100 capacity Discharging The UPS is supplying battery power to support the load This is caused by a utility power failure or battery test Charging The batteries are charging
80. e right upper corner of the event log table and select CSV or PDF file as the export file format The exported file will be saved in the default download directory of your web browser Status Records The Logs Status Records page is used to view the logs of the UPS status This page is only available for the Agent Status Records Fitter gt Refresh Save v input Vott Vv Output Mob Vi input Frea Hz Output FreafHz Loads Logs Status page Additional log pages can be accessed by selecting Previous and Next in the upper right corner of the Status Records page Clicking Refresh will update the log result to display in the list according to the current filter options and paging settings The time displayed at the upper corner displays the local time of the hosted computer This time may be different from the time on your computer Export 65 CyberPower Reliability Quality Value Click the Save shortcut at the right upper corner of the status record table and select CSV or PDF file as the export file format The exported file will be saved in the default download directory of your web browser Filter Users can use the following filter options by clicking Filter in the right corner Once the configuration of the filter panel is changed the filtered logs will be displayed status Records _ Partial entries are filtered Display all 2040 08 19 10 37 PM PD x Days 2009 08 30 FA 2009 09 01 H All Thisday Lastda
81. e threshold The sensor on the UPS PDU ATS has the following states according to the relative humidity Normal Indicates the humidity as a percentage measured by the sensor is in a predefined normal range Over wet Indicates the current humidity exceeds the high humidity threshold Overdried Indicates the current humidity violates the low humidity threshold A group has the following states according to the total power consumption Indicates the total power consumption of the group falls in the normal range Indicates the total power consumption of the group exceeds the high threshold Indicates the total power consumption of the group violates the low threshold Device Management Add Device In order to monitor and control UPS PDU ATS it first must be added to the Center by clicking Add Device button on the toolbar Power Equipment Management ag Ee Add Device button on toolbar Or it can be added directly to a group by selecting the Add Device item in the context menu for the selected group 8 CyberPower Reliability Quality Value Block A Add Group 4 On Maint PDU Rename Normal PDUi Move CA Normal Remove PDU2 el RMCARE Normal Details Add Device item in the context menu of target group ee Network com a WEL PR s Enter the comma separated IP addresses in the Device Address field or select the IP addresses by clicking Browse The
82. e unattended installation set the installationDir parameter blank The installer will automatically detect where preinstallation PPBE directory locates and attempt to complete the upgrade installation Computers which never installed Agent or Client can be installed the PPBE by assigning a valid path Assigning a blank path to the installationDir parameter during the unattended installation will allow the installer to use the default path as the installation directory C Program Files CyberPower PowerPanel Business Edition will be the default installation directory in Windows systems opt ppbe or usr local ppbe will be the default installation directory in most Linux distributions Help Content The Content page provides an overview which introduces the brief functions of what Agent Client and Center to do and indicates how to get related online help content for current function page It indicates a button to access to online help directly About The About page is an overview which includes the PowerPanel Business Edition and host operating system It also provides resources to contact website for assistances and the EnergyWise version that is using Logout The Logout page allows users to log the user out of the web interface The user will be asked if they are sure that they want log out and users can then log out by clicking the Logout button CyberPower Reliability Quality Value Using PowerPanel Business E
83. ecipient Test Sends the notification in accordance with current settings in order to verify the function The service can be tested only when the corresponding service on the Event Action Settings page is configured as activated Plan The dots and line indicates the specific days and time to send a defined notification to the recipient When an event occurs at the activated time of the activated days the notification will be sent to recipients Recipient Name E mail XMPP WLM y a amp a Tomas a server Room Admin A a a X Database Admin on PCZ a a a ag Backup Sever Admin a a a y File Sewer users a a The dots and the line indicate the specific time and day of the week to notify the recipient of the event Action Settings Settings page allows for configuration of various event actions including the necessary shutdown time of the hosted computer CyberPower Reliability Quality Value After configuring all of the action parameters and applying the settings the Verify button can be used to verify whether the user s configurations are correct To test whether a notification is configured properly and a recipient can receive the notification successfully use the Test function on the Event Action Notification Recipient page Each action has its own Activate option to specify whether to use the service to send a notification If No is checked the Verify button and the corresponding Test function wil
84. ecute the commands When an event occurred and enters OCCUR stage the assigned commands will be executed When an event is ended the variable will be FINISH and the assigned commands will be executed EVENT Indicates which event is fired to execute the commands EVENT_CONDITION Indicates which the detailed event condition of a firing event MODULE_NO Indicates which UPS module on a firing event This variable is used on Modular UPS models Users can know how to configure commands from the following table which lists all details of Y EVENT and EVENT_CONDITION BATTERY_CRITICAL_ LOW ENTER_BYPASS BATTERY_EXHAUSTED Battery capacity Is critically low Enters bypass mode The battery has been exhausted LOSS REDUNDANT ABNORMAL FATAL_ABNORMAL NO NEUTRAL WIRING_FAULT OUTPUT_OVERLOAD BYPASS OVERLOAD MODULE OVERLOAD SHORT CIRCUIT MODULE RECTIFIER OVERHEAT MODULE INVERTER OVERHEAT MODULE INVERTER PROTECTED Power redundancy is not enough UPS is abnormal Input is no neutral Site wiring fault UPS is fatal abnormal Output is overloaded Bypass is overloaded Module is overloaded Output circuit short Module rectifier is overheated Module inverter is overheated Module inverter is protected 50 CyberPower Reliability Quality Value BATTERY REVERSED The polarity of battery is reversed BYPASS SEQUENCE ERROR The phase sequence of bypass is wrong COMMUNICAT
85. ed The account which is used to receive WLM notifications may be not available Using the Test button of the WLM account field to verify is recommended The port 1863 used by the WLM service on PPBE software may be blocked by a firewall The shutdown occurs earlier than expected time It may be caused by the following conditions When batteries have been used for a long time they are unable to reach a full charge Check to see if the output load is too high A high load on the UPS will cause the batteries to discharge faster and the remaining runtime quickly decrease Disconnect some load from the UPS to reduce the load in order to extend the runtime Verify that the batteries are fully charged If the capacity is too low please charge the batteries to full capacity Pages cannot be displayed after set up another port number in the Security Network page The port that was set up in the Security Network page may be occupied by other applications or services This indicates that the pages can t be accessed through the assigned port Follow below steps to continue accessing the Agent Client Center web Find the webserver xmli file located at lt nstallation_directory gt etc agent folder on the Agent computer or lt Installation_directory gt etc client folder on the Client computer Use the text editor to open the webserver xml and you can find the lt httsPort gt tag in the file as below example lt xml version 1
86. ent to establish communication Follow these steps to add a USB connection Launch vSphere Client to click edit virtual machine settings to the target vMA gm 168 10 138 ySphere Cliert kee K Cen Ke SS File Edit View Invertory Adminstration Plug ins He oo e d re A ma k DN go D I 92 08 80 138 i vSotere Management Acuntart VMA e ry i gt Sestetey Herrag iegur Pefureence Fvente Come Peieiesiare vS teg Vanagevrert 4esalars vo af What is a Virtual Machine A wriual machine ts a software computer fiat tke a MWSKG tomp ile uns ei Operatry cysiem and ppicaions An operaling system insiaied on a la machine amp Caled a gues oporaing systern 1 KE Tun 1 e t Se yi as L al KI 4 fe E kia pirato I machines run op hos d i ef eh j A Basic Tasks gt Power on the virtual machine gt Eat virtual machine settings i E Tuks Suiten Mode don nmg wo A 128 CyberPower Reliability Quality Value Click Add button of the VMware Machine Properties to add a USB controller vSphere Management Assistant vMA Virtual Machine Properties Hardware Options Resources Memory Configuration M Show All Devices Hardware H cPus St ment a EZ Video card Video card Sse eine SR vie SCSI controller 0 LSI Logic Parallel Gy Hard diski Virtual Disk ERP Network adapter 1 VM Network auitrecommenced for Minimum recommended for this be ir Am CO
87. eplaced This should be set at the time of battery replacement If this date has not been set it is recommended that this date should be set immediately External Batteries The amount of external battery packs connected to the UPS Outlets The amount of outlets on the PDU ATS UPS The UPS tab allows you to set up to connect the PDU with the monitored UPS in the Center Select the Connect to UPS option Enter UPS IP address and assign the connected outlet Click OK button to initiate a negotiation to connect PDU with a UPS When the PDU connects to the UPS successfully this PDU connects to the assigned outlet All Clients which have communicated with this PDU will also establish the communication with UPS The UPS tab also allows you to set to connect the ATS with the UPS in Center Select the Source A connect to UPS or Source B connect to UPS option Enter UPS IP address and assign the connected outlet for according input source of ATS Click OK button to initiate a negotiation to connect ATS with the UPS When ATS connects to the UPS successfully all Clients which have communicated with ATS will also establish the communication with UPS Do not connect both sources to one single UPS An ATS whose sources come from the same UPS cannot protect connected computers and equipment from the power outage When one or more Clients are detected not to establish the communication with the UPS the Center will show a warning to inform users o
88. equence error The sequence of phases is different between utility and bypass Communication lost Communication between the UPS and computer has been lost Computer cannot have good communication with the UPS via USB serial port or network that conditions includes WR Local communication lost Communication between the UPS and computer via USB or serial cable cannot establish or was lost WR Network communication Lost Software cannot establish communication with UPS or PDU on the network or established network communication has been interrupted UPS is faulty UPS has malfunctioned in internal UPS may not be operating as user s desire and cannot afford power protection Conditions include Bypass Fan fault Bypass Fault Module Rectifier Fault One of module rectifier is faulty this module will stop supplying output power Module Inverter Fault One of module inverter is faulty this module will stop supplying output power Module Fan Fault One of module fan has been malfunctioned Note Batteries are not present and A schedule has initiated events are only available in the Agent More events are available for the Client The output power is going to stop soon Output power will stop due to power event or user commands When an UPS or a PDU is about to stop supplying the power to a Client computer the Client will be notified The Client will shut down the hosted computer Cannot establish network communication with Power Devi
89. er rating Watts of the UPS Current Rating The output current rating Amps of the UPS PDU ATS Voltage Rating The output voltage rating Volts of the UPS PDU ATS Frequency Rating The output frequency rating Hz of the UPS Battery Replacement Date The date that the batteries were last replaced NCL Outlet The amount of NCL Non Critical Load outlets in the UPS Extended Battery Pack The number of extended battery packs connected to the UPS Name The name of the UPS PDU ATS Location Where the UPS PDU ATS is located Contact Who to contact about the UPS PDU ATS CyberPower Reliability Quality Value MAC Address The MAC address of the UPS RMCARD PDU or Agent s network interface IP Address The IP address of the UPS RMCARD PDU or Agent s network interface Click the hyperlink to open the web interface of the UPS RMCARD PDU or Agent UPS on Source A Indicates which UPS connects to input source A of ATS UPS on Source B Indicates which UPS connects to input source B of ATS Environment Sensor Indicates whether the environment sensor has been installed on the UPS PDU ATS Note When the sensor cannot be detected anymore it will be annotated No Response Users can click the Uninstall to reflect it if it had been removed physically from the UPS PDU ATS Configuration In order for computers which have been installed PowerPanel Business Edition Client software to be aware of the state and get shutdown protection from
90. er standby power source after a power outage ATS is an abbreviation for Automatic Transfer Switch Environment Sensor A sensor accessory that can be installed on UPS PDU ATS for monitoring environment condition and obtaining information about the temperature and humidity 134
91. es the measured temperature from the environment sensor Environment Humidity Indicates the measured humidity from the environment sensor Contact Indicates generic equipment connects to this sensor Users can define the name and state in RMCARD web for each contact and monitor the state is normal Source A Voltage The voltage of the input power supplied to the source A of ATS Source B Voltage The voltage of the input power supplied to the source B of ATS Load The power draw of PDU ATS supplying power to connected equipment Bank Load The power of the PDU ATS bank supplied power to the connected equipment Information Information tab shows information about the UPS PDU ATS Type The type of the device such as On Line Line Interactive or Sinewave Line Interactive for UPS or Monitored or Switched for PDU ATS Model Name The model name of the UPS PDU ATS Firmware Version The firmware version of the UPS PDU ATS 90 CyberPower Reliability Quality Value MAC address The MAC address of the UPS RMCARD PDU or Agent computer s network interface Serial Number The serial number of the UPS Note This will give the internal serial number on some models Power Rating The Volt Amp rating VA and power rating Watts of the UPS Voltage Rating The output voltage rating Volts of the UPS Frequency Rating The output frequency rating Hz of the UPS Battery Replacement Date The date that the batteries were last r
92. eshold Group Power consumption is too high Power entire devices consume has been exceeded the high threshold Power consumption is too low Power entire devices consume has been violated the low threshold UPS Remaining runtime will be exhausted Remaining runtime will be exhausted and is not sufficient for a complete shutdown System is overheated he sensor measures the UPS temperature exceeds the high threshold Network communication lost Center cannot establish communication with UPS on the network or established network communication has been interrupted UPS is faulty UPS has malfunctioned in internal UPS may not be operating as user s desire and cannot afford power protection Utility power failure Utility power failure battery power will be supplied Battery is not present Batteries are not present the UPS cannot provide battery power in this condition Available runtime is insufficient There is not sufficient runtime for a complete shutdown even if battery has fully recharged UPS is fatal abnormal UPS is working abnormally due conditions includes as following list that may cause UPS shutdown and no longer supply power soon or even immediately Power consumption is too high Power the specific UPS consumes has been exceeded the high threshold Power consumption is too low Power the specific UPS consumes has been violated the low threshold Shutdown initiated A computer which connects with UPS initiated the shut
93. estart the PowerPanel Business Edition service For windows restart the service from the PowerPanel Business Edition Service gt Services gt Administrative Tools gt Control Panel 132 CyberPower 21 22 Reliability Quality Value For Linux run the commands in order to restart the service sudo service pobed stop and sudo service ppbed Start How do I change the password to access the trust list of PowerPanel Business Edition The default password is changeit User can edit lt PPBE_installation_directory gt web etc cacertpd in the text editor to replace the default password with the default one PPBE_installation_directory is the directory to install the PowerPanel Business Edition cannot add the new SSL certificate into the trust list Due the duplicate alias name is available in the trust list the certificate cannot be added In order to add the new certificate into the list the certificate which has the duplicate alias name should be removed from the list Follow the steps to remove the certificate Switch to the lt agent_installation_directory gt jre lib security directory in the command prompt cd lt agent_installation_directory gt jre lib security Run the below command to remove the certificate from the trust list lt agent_installation_directory gt jre bin keytool exe delete alias lt alias_name gt keystore cacerts Enter changeit as the password for the certificate removal E
94. f this condition Energy The Energy tab shows the chart how to spend the energy in a specified period and also shows the energy statistics of the current target node and entire system Each UPS PDU and ATS whose consumption will be logged per hour and each group which contains these UPS PDU ATS will work accumulating the consumption of data These data which logged the consumption in the past can be gathered to render a chart in a past day a past month a past year and a past decade accordingly Administrators will realize how much energy has been spent in a past period Energy can be spent more efficiently and reduce the waste The Energy tab allows administrators to configure the proper thresholds to aware of violating consumption thresholds Once the power consumption violates thresholds Center will warn administrators of the violation The thresholds are only applicable to current group or power equipment When the thresholds are set blank Center will use the thresholds of the Default Energy in Energy Consumption Settings page instead of thresholds in Energy tab 91 CyberPower Reliability Quality Value Note Internet explorer 6 and lower versions cannot support the graphic chart The Internet explorer should be upgraded to the higher version which is capable of rendering the graphic charts Device Operations Center provides management functions for a UPS PDU ATS Computers on Outlets Shutdown Restart A shutdown
95. fari cant verify the identity of the website 192 168 22 53 The certificate For this website is invalid You might be connecting to a website that is pretending to be 197 168 22 53 which could put your confidential information at risk Would you like bo connect to the website anyway Show Certificate Safari displays the security certification alert Note The performance will be lower once accessing to the website over the HTTPS connection SSL Certificate Import SSL Certificates The user s browser that connects with the PowerPanel Business Edition web interface will serve the SSL certificate The certificate proves to the browser that the provider believes that it has issued a certificate to the owner of the PowerPanel Business Edition The Security Network page allows users to import your own SSL certificate and SSL Certificate displays the date and result for the last time to import SSL certificates Users can import the certificates as following steps Click the Settings button to switch the SSL Certificates Wizard Click the Import button to upload the SSL certificate file Enter the Key Passphrase field and the Keystore Password field Click the Continue button to import the SSL certificates 78 CyberPower Reliability Quality Value Note Applying for a certificate from the commercial certificate provider will be subject to the provider fee Add SSL Certificate into Trust List A certificate t
96. for shutdown protection in a UPS or PDU click Yes on the Shutdown Protected option enter the IP address of computer and then click the Apply button to complete If you want to plug generic equipment that have not been installed or cannot install PowerPanel Business Edition Client software for shutdown protection in a UPS or PDU click No on the Shutdown Protected option enter the name and optional information for the equipment and then click the Apply to complete Clicking the reversed triangle icon helps to input IP address of computer easily and quickly A drop down list shows the search result of available computers that have been installed PowerPanel Business Edition Client software Clicking the rotating arrow will start a new search to update the search result Change the load information Click the target load you wish to change from the list Update the data in editable fields and then click Apply to complete Move load s plug to another outlet Click the target load you want to move from the list If you want to move the load s plug from one outlet to another one assign the target outlet in the Outlet option if you want to move the 38 CyberPower Reliability Quality Value load s plug from UPS to PDU from PDU to UPS or between PDUs assign the target UPS or PDU in the Device option and then click Apply to complete Unplug the load from UPS or PDU Click the target load you wish to unplug from the list Click No o
97. formation Name Receiver IP Community Status Control ee 7 UPS Control 1 Test 192 168 20 54 public Enable UPS Reboot Schedule Add a new Irap Receiver to notify System System Time User Accounts Identification Network TCP IP Access Control Trap Notification Events Event Log Event Generation UPS Shutdown Summary Logout Network Trap Notification page in the UPS RMCARD201 web SNMPv3 The Client uses the below SNMPv3 settings to interact with a secure device These settings can be configured on the Security Authentication page in Client and on the Network Service SNMPv3 Service page of the UPS RMCARD PDU ATS web These settings must be matched User Name Specifies a username match for protocol Authentication Protocol Sets the protocol to be used for authenticating the network communication between the Client and devices Authentication Key Sets the authentication key which is used for the aforementioned authentication protocol Privacy Protocol Sets the privacy protocol to be used for encrypting data during transmission between the Client and devices Privacy Key Sets the privacy key to encrypt data for the aforementioned privacy protocol Network Data may be eavesdropped upon or falsified due to eavesdroppers or unknown network attacks when using the PowerPanel Business Edition HTTP is insecure and subject to eavesdroppers or other network attacks which can obtain the sensitive information such as website accounts
98. he Add Computer Equipment window will z appear Expand All All computers and equipment will be visible by clicking this button The Toolbar also displays the amount of times monitored equipment have had severe level or warning level events occur which devices have lost communication with Center and which devices are normal Center cannot monitor or control computers and equipment when communication is lost 100 CyberPower Reliability Quality Value Indicates that there are no problems with this computers or equipment Node Components Each node is named and indicates what type it is A computer or generic node provides more information A context menu for each node can be accessed by clicking icon This allows you to view detailed information such as Summary and request operations such as Shutdown or Restart A menu item becomes disabled when this operation is in progress or is not Supported Ai 1 Serer Room Computers xp testing Power Control Power Off ad Unclassified Add Group Data Excha Power Cycle Add Computer Equipment RSS Publis Rename Move Remove Expand All Details A context menu appears by accessing a computer node Each node can be one of the following types Computer A computer which has Agent installed and is supplied power by the UPS Computer A computer which has Client installed Generic Equipment Equipment which m
99. he Login page When the secure level has been changed from Basic to Sensitive Complete the browser warning will be presented after the new level is taken effect This indicates that the user s browser considers the connection is risky Users can ignore the warning page and continue the web access or provide a SSL certificate which is produced by the commercial certificate providers or any trusted certificate authority igs CyberPower Reliability Quality Value If the user would like ignore the warning page refer to the Ignore Warning Messages section to continue web access If the user has his own SSL certificate refer to Import SSL Certificates section for further details how to import the new certificate Ignore Warning Messages Users that plan not to import the SSL certificate may have to ignore these warning and continue the web access Below illustration are the warning pages displayed on popular browsers Follow the steps according to your browser to continue the web access Internet Explorer Click Continue to this website not recommended in order to proceed There is a problem with this website s security certificate The security certificate presented by this website was not issued by a trusted certificate authority The security certificate presented by this website was issued for a different website s address Security certificate problems may indicate an attempt to fool you or intercept any data you send to th
100. he default username is admin and the password is admin For security it is recommended to change the username and password on the Security Login page after the initial login 7 A pr gn PowerPanel ai A on H EA s PowerPanel Business Editiot Usemame admin Password enges J Remember me on Ra LOGIN The local and remote login pages are the same Selecting the Remember me on this computer option on the login page allows the credentials to be remembered for automatic logon at the next session To terminate the session click the Logout button on the Logout page The session will timeout and you will be logged out if no activity takes place during the time of Session Timeout The Session Timeout can be configured on the Security Login page Essential Setup In order to ensure the PowerPanel Business Edition software functions properly make sure that the Agent Client and Center have been configured correctly 21 CyberPower Reliability Quality Value Agent Make sure a USB or serial cable is connected between the Agent computer and the UPS If Agent is installed on a vMA running on an ESXi host refer to FAQ chapter for further details how to add USB connection If Agent is installed on a VMA running on ESXi 5 x refer to FAQ chapter to upgrade virtual hardware in order to add the USB device of target UPS NCL Non Critical Load outlets on specific models are designed to shut off under certain circumsta
101. ich is used by the Client to access the PDU 7 The web interface is displayed abnormally due to large or tiny size on Google Chrome 3 lt is caused by the default settings for minimum font size on the Google Chrome Verify the below steps to improve the web pages due to font size Close the Chrome first Find the preference file located at Documents and Settings Users_Name Local Settings Application Data Google Chrome User Data Default Preferences in Windows XP and Users User_Name AppData Local Google Chrome User Data Default Preferences in Windows Vista Use the text editor to open preference file You will find the keyword webkit in the file and insert minimum_font_size and minimum_logic_font_size in the below example webkit webprefs default_fixed_font_size 13 default_font_size 16 tixed_font_family Courier New minimum_font_size 10 minimum_logical_font_size 10 EE skipped 121 CyberPower 10 Reliability Quality Value Set both minimum _font_size and minimum_logic_font_size to 10 in order to display the pages normally Save the preference file and launch the Chrome again to access PPBE software The PPBE software cannot send WLM notifications in case of power events The account which is used to send WLM notifications may be not available Using the Verify button on the Windows Live Messenger block to verify the account details is recommend
102. id Voltage If the utility voltage is in range of the voltage thresholds the UPS will enter bypass mode Otherwise the UPS will stop supplying output power WR Never Bypass If this option is selected the UPS will not enter bypass mode and will stop supplying output power Mandatory If this option is enabled the UPS always enters bypass mode due to a fault or overload even the utility voltage is outside of the normal range Otherwise the UPS will stop supplying output power Caution Bad utility voltage while in bypass mode may damage the connected equipment Manually Execution Determines whether to allow the UPS to enter Manual Bypass mode If this Start option is selected the UPS will be forced to enter bypass mode Caution Make sure that the UPS is not using generator power or converted power When the UPS enters bypass mode the UPS will use input power to supply to equipment The unstable frequency of the input power may damage connected equipment Caution If this option is enabled the UPS can t function in the Generator mode Voltage Upper Lower Bound When a UPS fault or overload occurs UPS will determine whether to enter bypass mode according to range of thresholds from utility power If the utility voltage exceeds thresholds UPS will be forbidden to enter bypass mode and will stop supplying output power Overload This configures the ability of the UPS to switch to bypass mode and supply utility power when the Output is
103. in Name cyber Off State Cache Secure Mode a Shared Secret zeer Endpoint Agent Enable Endpoint Agent Fort Apply Children List Name Role Keywords Importance Apply Name Role Keywords Importance 0 UPS Base base role endpoint child base 1 Parent 1 UPS ups role endpoint child ups 1 2 CLBank cl role bank endpoint child cl bank 1 Connect with Cisco Switch Users can enter all required data and click Apply button to establish connection with the Cisco switch Access Port Sets the port for Agent to interact with Cisco switch The default port is 43440 Domain Name Sets the domain name for Agent interact with the Cisco switch The default domain name is cyber Off State Cache If this option is enabled Client will be allowed to be cached its own endpoint data on the Cisco switch when it becomes non operational Secure Mode Determines whether to use the shared secret to interact with Cisco switch Shared Secret Sets the secret for Agent to interact with Cisco switch The default secret is cyber Endpoint Agent Determines whether to establish the communication with Cisco switch 41 CyberPower Reliability Quality Value Endpoint Agent Port Displays the port between the Agent and EnergyWise service Agent will interact with Cisco switch through the EnergyWise service Start EnergyWise Service In order for Agent to establish the connection with Cisco switch enter the required data and
104. in progress or is not supported adi 1 Block A Computers on Outlets f Shutdown el CEA H Power Control sl DXRO Battery Test DI RMCA Ass E Block B Add Group Add Device Rename Move Remove Expand All Details A context menu appears by accessing a device node Each node can be one of the following types A UPS This UPS may have an RMCARD or is connected to a computer which is controlled 85 CyberPower Reliability Quality Value Came SOS Each node also has a column that indicates what the current state is and what power events have occurred The column in a UPS node displays power events such as Utility power failure or Runtime is insufficient event while the column in a PDU node displays power events such as nput is low load or Input is overload The UPS PDU ATS nodes display a brief operating status consisting of schedules utility power batteries support load and outlets The brief status column displays in gray when local or network communication has failed A UPS can have the following states Normal The UPS is working normally Power Failure There is no utility power supplied to UPS Bypass The UPS has switched to bypass mode and is supplying direct utility power 7 Boost The utility voltage is below the regular voltage and UPS is increasing the utility T voltage Buck The utility voltage is beyond the regular voltage and UPS is decreasing the utili
105. ing icon This allows users to view detailed information such as Summary A menu item becomes disabled when this function is not supported Each node can be one of the following types Indicates that is a VMware vCenter server E Indicates that is a VMware ESXi host The ESXi host may be included by a vCenter server Indicates that is a virtual machine running on the VMware ESXi server Service Infrastructure Management Add an Infrastructure In order to monitor and control the VMware infrastructures users can click the Add Infrastructure button on the toolbar An Add an Infrastructure dialog will appear for users to add an infrastructure Service Infrastructure Management The detailed data describes as below Add an infrastructure on the toolbar Product Specifies whether to add a vCenter server or an ESXi host IP Address Name Configures the IP address or hostname for the vCenter server or the ESXi host Port Sets the port number for Center to access the vCenter host Username Sets the user name to access the vCenter server or ESXi host Password Sets the password for the username Attach plugin to vCenter Server Decides whether to attach a vCenter server plug in If this option is enabled Center will install a plugin which expands the capability of vCenter server to present the Center web interface during establishing connection After the plugin is installed the vSphere Client interface will attach
106. ing event will be also changed After the Custom option is enabled the selected event will be configurable Users can change the shutdown delay time for each event and click OK to apply the setting When the event occurs Center will take the new shutdown delay time instead of the default one that can be configured in the Event Action Events page Alarms for vCenter Server and ESXi Host The vSphere includes the user configurable events and alarms system The alarm system logs the events happening throughout the vSphere and allows users to specify the conditions under which alarms are triggered Alarms are notifications which are activated in response to events The Center will specify the alarm definitions for the vCenter servers and ESXi hosts selected in the inventory after the power source has been configured properly When the power event occurs the alarms will be issued from the Triggered Alarms view under the Alarm tab The Center defines the below alarms and issues the alarm when its related events are triggered Alarm Definition Description Triggered Event Trigger Level Communication lost with UPS in Alert battery mode Communication lost with UPS Warning Communication established Normal Alarm is triggered when PPBE lost communication with UPS PPBE UPS Communication Event 110 CyberPower Reliability Quality Value UPS Low battery Alert Alarm is triggered when a UPS Remaining runtime exhausted Ale
107. ion and enter a name for the PDU Click Apply to complete Install an ATS on UPS Select the Install ATS from the dropdown menu by clicking the Power Distribution shortcut on the list Assign the target UPS outlet that the ATS has plugged in select the target input source of ATS to connect with UPS and enter the network address of ATS Click Apply to complete Move PDU ATS s plug to another UPS outlet Select the target PDU ATS tab you want to move Select Configure PDU ATS from the drop down menu by clicking the Power Distribution shortcut on the list and select another UPS outlet on UPS outlet option Click Apply to complete Uninstall the PDU ATS from UPS Select the target PDU ATS tab you want to uninstall Select Configure PDU ATS from the dropdown menu by clicking the Power Distribution shortcut on the list Select Disconnect PDU ATS with UPS option and click Apply to complete Note When a PDU SATS is uninstalled from the UPS all loads include generic equipment and computers on this PDU SATS will be removed computers will also no longer keep communication with the UPS Note PDU or ATS may be configured in the Power Configuration page of PPBE Client s web interface directly A named PDU SATS tab with tip Does PDU ATS connect to UPS will appear automatically to inform you to ensure it Note PPBE did not allow ATS to connect two input sources to one single UPS 39 CyberPower Reliability Quality Value SA Name Lo
108. ion Tools gt Event Viewer to review all events in the Application category of the Windows Logs directory Note Event Viewer is only function on the Windows platforms If this option is not activated you can activate this option by installing the PowerShell through Windows Update Status Recording Enable If this option is enabled the Agent will start to record the UPS status Entry Expiration This option specifies how long the log files will be retained Recording Interval The Agent will record the UPS status at the specified intervals Clear All Records When this option selected with Yes Now all record status logs will be removed immediately after clicking Apply The log clearing is permanent and once applied the log files cannot be recovered Schedule Di CyberPower Reliability Quality Value Shutdown In the Agent an active schedule will cause the computer to shut down or hibernate and then ask the UPS to completely power off the output or turn the specific outlets off at a specified date and time It also allows users to specify the date and the time to turn on output or turn the specific outlets on The UPS will turn on the specific outlets and begin supplying power which causes the computer to restart or wake from the hibernation Before the Agent shuts down because of a schedule shutdown Client computers running PowerPanel Business Edition Client will be shut down or hibernated to prevent data loss Th
109. ion be installed Select the Folder where you would like CyberPower PowerPanel Business Edition to be installed then click Next Destination directory C Program Files CyberPower PowerPanel Business Edition Required disk space 92 4 MB Free disk space 2 160 MB Choose the start menu directory P Setup CyberPower PowerPanel Business Edition Select Start Menu Folder web Where should Setup place the program s shortcuts S Select the Start Menu Folder in which you would like Setup to create the program s shortcuts then click West Administrative Tools FastStone Capture Games Click the Finish button to complete the installation CyberPower Reliability Quality Value P Setup CyberPower PowerPanel Business Edition Completing the CyberPower PowerPanel Business Edition Setup Wizard Setup has Finished installing CyberPower PowerPanel Business Edition on your computer The application may be launched by selecting the installed icons Click Finish to exit Setup Login CyberPower PowerPanel Business Edition Default username and password is admin CyberPower PowerPanel Business Edition has configured Windows Firewall settings Installation on Linux The installer is used to install the software and requires root permission The installation wizard will guide users in completing the installation Browse to the CD drive and find the installer in the Software Linux folder
110. ion is disabled the UPS will not restore output at that moment and users have to turn it on manually Mandatory Power Cycle When a shutdown sequence is initiated due to a power failure the connected computers may be ordered to shut down and the UPS will be also ordered to turn off after a time delay If the utility power is restored prior to the UPS shutting off the UPS will still turn itself off In this circumstance the utility power has restored but the connected computers have shut down and the UPS has turned off If the Mandatory Power Cycle option is enabled the UPS will also turn off after a time delay but it will turn on again about 10 seconds later The UPS has restarted and then all connected computers will boot Recharged Delay When the utility power is restored the UPS will start to recharge until the specified delay is expired before restoring output power Recharged Capacity When the utility power is restored the UPS will start to recharge until the specified battery Capacity is met before restoring output power Startup Delay When the utility power is restored the UPS will delay the restoration of output power This option can be used to stagger the startup time of multiple UPS to avoid overloading the utility power circuit or power source The Startup Delay option will take effect every time when the UPS is about to restore power This also includes the scheduling task Stable Utility Delay When the utility power is rest
111. ion window will appear Click OK to initiate the shutdown or restart This is only available for a computer with Agent or Client installed Power Control Power Off Select Power Off from the context menu Decide whether to turn off the outlet immediately or in sequence Click OK to turn off the outlets A computer which has Agent or Client installed will initiate a graceful shutdown prior to turning off the outlet On specified modes turning off or restarting one outlet of the bank will also turn off other outlets of this bank This may cause other computers on this bank to be shut down unexpectedly Power On Select Power On from the context menu Decide whether to turn on the outlet immediately or in sequence Click OK to turn on the outlet Power Cycle Select Power Cycle item from the context menu Determine whether to restart the outlet Click OK to proceed A computer which has Agent or Client installed will also initiate a shutdown prior to restarting outlet Turning off the outlet of a bank restarting the outlet of the bank will also cause other computers on other outlets to be shut down Locate Select Locate from the context menu The computer uses speakers to generate the audible sounds Service Infrastructure Service Infrastructure page provides the management for infrastructures such as VMware virtualization 106 CyberPower Reliability Quality Value Service Infrastructure Management kA wa 0 3 Refresh T
112. l be disabled The column displayed in the recipient list will be marked gray to indicate that action is disabled Shutdown Necessary shutdown time This setting will set the amount of time which Agent and Client computers will take to shut down The host computer will initiate the shutdown before power is stopped from the PDU or UPS in order to avoid a sudden blackout This setting should be configured to allow for the normal shutdown time of the computer When Client connects to a PDU outlet the shutdown time must be set properly to avoid the delay off time of the connected inability to support a complete shutdown When a PDU performs a sequenced off reboot action each outlet has a specified delay time delay off before it is turned off This delay time must be greater than the Necessary shutdown time required by a Client computer The Client will communicate with the PDU to verify whether this delay time is sufficient If the delay time is insufficient a warning message will display The user can expand it and configure the outlet delay off of the PDU or configure it in the PDU web interface manually The warning message will be visible until these options are setup properly Note This function must have write permission See Security Authentication for more details If the Client is given write permission on the PDU it can setup the PDU directly shutdown Necessary shutdown time 5 e minutes Warning o The system may not shutdown properly d
113. lation Please follow the below steps resolve the problem Make sure that there is no other application utilizing port 3052 UDP TCP and port 53568 TCP Use a command prompt with the command netstat o to obtain information about which ports are used by which programs e Ensure the PowerPanel Business Edition service is running on the hosted computer If the service is stopped restart the service and then try again in the same way Make sure the port 3052 UDP TCP and port 53568 TCP on the hosted computer are not blocked by a firewall Make sure the URL in the address filed of the browser for a remote computer is correct have installed the PowerPanel Business Edition Agent on my computer but the Agent cannot establish communication with the UPS Make sure that no other application is using the serial port if the UPS is connected with a serial cable Make sure the serial or USB cable is securely and properly connected to the UPS and computer The Client cannot establish communication with the UPS PDU ATS The lack of communication may be caused by the following conditions The network communication between the Client computer and the UPS PDU ATS is down The device network address is configured improperly The authentication settings are configured improperly Follow the steps below to resolve the problem Verify the device network address is correct 120 CyberPower Reliability Quality Valu
114. ll equipment connected to the outlets labeled both SURGE and BATTERY or all the outlets on the UPS includes labeled CL NCL NCL 1 NCL 2 will be turned off Only the UPS with NCL support the NCL outlets are available and if there are two NCL outlets on the UPS the NCL 1 NCL 2 outlets are available Caution Surge protected outlets provides surge protection to the equipment but does not provides battery power once a power outage occurs When utility power fails computers on the surge outlets will be shut down immediately due to power loss Turn off the NCL outlet If the NCL option is chosen users can assign a scheduled shutdown to particular outlets on the UPS with NCL support If there are two NCL outlets on the UPS the NCL 1 and NCL 2 outlet can be assigned individual schedules Frequency There are three frequencies that can be assigned Once Daily and Weekly Daily and Weekly schedules will be repeated If a Once schedule has been performed or expired the schedule will display a gray active icon in the schedule list Restore Time Active Shutdown Time Freauency 2011 0614 05 25 PM 2011 0614 06 25 PM 2011 0615 04 15 AM 20110615 05 15 AM Daily Force shutdown for power s ag 2011 0616 04 15 AM 2017 0616 05 15 AM Weekly All server backup amp Maintain 2011 06 19 02 15AM 2011 06 19 03 15 AM Once NCL Test Schedule 2011 06 20 02 15 PM 2011 0620 03 15 PM Once NCL Test Schedule a A once schedule with a gray active
115. llation Setup CyberPower PowerPanel Business Edition Completing the CyberPower PowerPanel Business Edition Setup Wizard Setup has finished installing CyberPower PowerPanel Business Edition on your computer The application may be launched by executing the installed start scripts Click Finish to exit Setup D Login CyberPower PowerPanel Business Edi Default username and password is admin Finish Installation on Text Mode When the system does not support graphic mode the Linux installation needs to be initiated in the terminal by using the ppbe linux x86 sh c command on 32 bit systems or use ppbe linux x86_64 sh c command on 64 bit systems The installation procedure will be initiated as following steps Press Enter to start an installation Starting Installer This will install CyberPower OK o Enter Cancel c ege Accept the license agreement 13 CyberPower Reliability Quality Value OUR ACCEPTANCE OF THE FOREGOING AGREEMENT WAS INDICATED DURING INSTALLATION I accept the agreement es 1 No 2 Choose the component If one single computer is connected to the UPS directly via a USB or serial connection Agent should be installed If the computer is powered by a UPS already connected to an Agent has a remote management card installed or is connected to a PDU Client should be installed If the administrator requires simultaneous monitoring and acces
116. lled the customized battery packs the option should be set Customization Periodical Battery Test The UPS will periodically perform the battery test to ensure the batteries are fully functional Extended Battery Pack Sets the amount of extended battery packs This allows for an accurate runtime estimate based upon the total number of batteries Boost Charge Period Sets the period for UPS batteries being boost charged automatically and periodically Discharge Duration Limit Sets the duration to limit the battery discharging to avoid a deep discharge excessively System Cold Start Sets the ability of the UPS to start in the absence of input power When this option is enabled the UPS can be turned on without having input power Short Circuit Recovery Detect When the output of the UPS causes a short circuit the output will turn off immediately If this option is enabled the UPS will inspect the circumstance of the short circuit 3 times in 30 seconds If the short circuit is no longer present the UPS will restore power If the circumstance of the short circuit still remains the UPS will not supply power Utility Power Failure Alarm If this option is enabled the UPS will issue an audible alarm when the utility power fails Overload Alarm Threshold When the output load exceeds this threshold the UPS will issue an audible alarm Generator Mode If the UPS is using a generator for its input power this option should be enabled for UPS to f
117. ly store this exception option and click Confirm Security Exception button to continue the web access Google Chrome You are about to override how Firefox identities this site Legitimate banks stores and other public sites will not ask you to do this Server Location Vaedaka fvhkR E EE il Certificate Status This site attempts to identify itself with invalid information Wrong Site Certificate belongs to a different site which could indicate an identity theft Unknown Identity Certificate is not trusted because it hasn t been verified by a recognized authority Permanently store this exception Contirm Security Exception Click Proceed anyway button to continue the web access T CyberPower Reliability Quality Value A The site s security certificate is not trusted You attempted to reach 192 168 22 53 but the server presented a certificate issued by an entity that is not trusted by your Computere operating system This may mean that the server has generated its own security credentials which Google Chrome cannot rely on for identity information or an attacker may be trying to intercept your communications You should not proceed especially if you have never seen this warning before for this site Back to safet P Help me understand Google Chrome displays that the security certification is not trusted Safari Click the Continue button to continue the web access Sa
118. m sudo chmod u x ppbe XXxX linux x86 sh XXX is the version number of PPBE Run the below example command to change its permission of the 64 bit installer on 64 bit Linux platform sudo chmod u x ppbe XXxX linux x86_64 sh XXX is the version number of PPBE After the permission of the PPBE installer is changed the installation procedure will be allowed to launch Inability to Shutdown NAS during Power Failure When using sshpass tool cannot shut the NAS down during power failure the version of the sshpass tool may be 1 04 The sshpass tool whose version is 1 04 will result in inabiltiy to shutdown NAS You must check whether the version of the sshpass tool is 1 04 If the version is 1 04 you must change another version FAQ If multiple computers are connected to a single UPS how do I determine which computer to install the Agent or the Client on to ensure each computer can be shut down gracefully in event of power outage The computer that is connected to the UPS with a serial or USB cable should install the Agent and the remaining ones should install the Client After the PowerPanel Business Edition installation is complete how do access the web interface On Windows you can select the Start gt All programs gt PowerPanel Business Edition gt PowerPanel Business Edition Agent or PowerPanel Business Edition Client PowerPanel Business Edition Center for local use You can also enter the URL http hosted_computer_ IP
119. mplate Name and Location ppbe 3 _centos 662 2 MB 1 5 GB thin provisioned 20 0 GB thick provisioned PowerPanel Business Edition software Agent provides the service which communicates with the UPS through USB or Serial cable and relays the UPS state to each Client on other computers via a network It also monitors and logs the UPS status The computer which has been installed the Agent provides graceful unattended shutdown in the event of the power outage to protect the hosted computer lt Back nets Cancel E Specify a name and location for the deployed template SOUrce Name 7 OVE Template Details Name and Location Disk Format The name can contain up to 80 characters and it must be unique within the inventory folder Back next gt Cancel E Select the virtual disk format for the PPBE virtual appliance The default option is Thin Provision Refer to About Virtual Disk Provision Disk Policies for further information about how to select virtual disk format CyberPower Reliability Quality Value E Deploy OVF Template Disk Format In which format do you want to store the virtual disks Source Datastore datastore 1 OVE Template Details Name and Location Disk Format Besdy ta Comnlete Ready to Complete Available space GB 123 1 Thick Provision Lazy Zeroed Thick Provision Eager Zeroed e Thin Provision ceo Jess ze E A deploymen
120. n Use the same command to mount CD and initiate the installation procedure Before installing Agent with the USB connection make sure the host supports USB connection ESX 4 1 does support USB devices Refer to Installation on Text Mode section to complete the installation Virtual Appliance Deployment on ESXi A virtual appliance VA is a prebuilt software solution comprised of one or more virtual machines that is packaged maintained updated and managed as a unit It is fundamentally changing how software is developed distributed deployed and managed Download the PPBE virtual appliance which is pre installed Agent and Client from CyberPower In order to deploy the PPBE virtual appliance on VMware ESXi host users must install vSphere Client tool on another remote computer first To download vSphere Client tool users can enter the ESXi host IP address to access web page of ESXi host The deployment procedure will be initiated as below steps Launch the vShpere Client Open the Deploy OVF Template window from File gt Deploy OVF Template item CyberPower Gah Quality Value Edit View Inventory Administration Plug ins Help Deploy OVF Template Report calhost cyberpowersystems com tw VMware ESXi 5 0 0 768111 b Il Inventory Browse VA Marketplace etting Started Sey ee ee eee tc ue Print Maps Nhat is a Host Exit A host is a computer that uses virtualization software such as
121. n the Enabled option and then click Apply to complete The PowerPanel Business Edition Client software can be installed on computers to benefit shutdown protection in order to ensure a proper shutdown in the extended power outage event and control demands in UPS and extended PDU Assigning a correct outlet is important The Outlet option must be configured to match the actual equipment plugged into the UPS outlet Depending on the UPS configuration of specific models with NCL outlets these outlets will lose power before the entire UPS is shutdown The Agent will request Client computers powered by these outlets to perform a shutdown to avoid data loss because of the power outage Manage PDU and ATS When the PDU or ATS connects with the UPS as extensible outlets users can manage these PDU ATS in the list on this page Anamed PDU or ATS tab whose list contains connected generic equipment and computers will be created due to the connection with PDU ATS from UPS and removed due to the disconnection with PDU ATS from UPS Install a PDU on UPS Select the Install PDU from the dropdown menu by clicking the Power Distribution shortcut on the list If the PDU has network function select Network from the PDU Type option enter the network address of PDU and assign the target outlet of UPS outlet that PDU had plugged in if the PDU is generic PDU without network function select the Generic from the PDU Type option select a PDU model from the Model opt
122. n will also start the service Linux Message Linux Message Activate D Yes No Apply Linux Message Activate Specify whether the Agent and Client can use this service to send a notification to all users accessing to this hosted computer Short Message Service SMS Short Message Service SMS is a communication service used by mobile communication systems using standardized communications protocols allowing the interchange of short text messages between mobile devices The Agent Client sends mobile text messages to a receivers mobile phone using an online SMS service Users can choose Clickatell as a platform to send SMS or any SMS provider which sends a message via E mail or HTTP All account information and E mail HTTP specification must be acquired from the service provider before using SMS The different SMS providers are described below Service provider is Clickatell Select the Clickatell option at the Service Provider field Complete all the account details from Clickatell with the Username Password and HTTP API ID fields The Verify function can be used once the Activate gt YES option is checked and this option is selected and parameters are applied 61 CyberPower Reliability Quality Value Short Message Service 5M5 Activate Yes No Service Provider Clickatell A User Name ppbe_user Password ees HTTF API ID Apply Verity SMS Short Message Service service Service provider acce
123. nces to save battery power and maximize the runtime on the remaining outlets The Agent computer should not be connected to NCL outlets Refer to PPBE Installation Guide for UPS without RMCARD for detailed information about how to plug the Agent computer into the correct outlets Configure the Necessary shutdown time option properly on the Event Action Settings page based off of how long it takes for that computer to turn off completely after a shutdown has been initiated Perform a battery test to verify the UPS can supply battery power to the connected equipment and the equipment operates properly See the UPS Diagnostics section for more details Client Setup the SNMP community the same as in the remote management card of the UPS PDU ATS or the Secret Phrase used by the Agent on the Security Authentication page Set the port used by Client on the Security Network page to match the port used by the Agent s port Assign the network address of the remote management card of the UPS PDU or Agent and assigning the connected outlet on the Power Configuration page Configure the Necessary shutdown time option on the Event Action Settings page based off of how long it takes for that computer to turn off completely after a shutdown has been initiated Center In order to establish communication with the UPS PDU Agent or Client Set the SNMP Community to the same one used in the UPS PDU ATS or the Secret Phrase used by the remote card of UPS
124. nel Business Edition service of FAQ chapter for further details about how to restart PowerPanel Business Edition service Note agent_installation_diretory is the directory where the PowerPanel Business Edition Agent installation locates cert_name is the filename of the certificate file and alias_name is the alias for the certificate available in the trust list Note The aforementioned steps are applicable to the interactions between PowerPanel Business Edition software Note Due to security reasons user may have to change the password to access the trust list Refer to How to change the password to access the trust list of FAQ chapter for more details Preferences User Experience The User Experience page is used to configure common settings for the user s experience The settings configured here will be used on the Event Action Recipient Logs Event Logs and Logs Status Records pages CyberPower Reliability Quality Value User Experience Working Day and Time Working Day Mon Tue Wed Thu Fri Sat Sun Duty Time SAM e SPM e Apply EnergyWise Enable Preferences User Experience page Working Day and Time Working Day Set the days users normally work Duty Time Set the work hours for users EnergyWise Enable Sets to activate the EnergyWise function This function is only supported in Agent and is not activated After this option is activated the EnergyWise item will appear in the UPS categor
125. nter y to apply the certificate removal Restart the Agent service to reload the trust list and take effect Refer to How to restart PowerPanel Business Edition service of FAQ chapter for more details Glossary Citrix XenServer A virtual machine monitor allows several guest operating systems to execute on the same computer hardware concurrently XenServer is supported by Citrix systems Inc IP address An IP address is a series of numbers that identifies a particular computer or NIC on a network IP is an abbreviation for Internet Protocol HTTPS Abbreviation for HTTP Secure It provides encryption and secure identification of servers by using HTTP with SSL TLS protocol HTTPS connection is usually used for the sensitive transaction Power Device Network Utility ls an easy to use tool to setup network configurations of the UPS RMCARD PDU ATS This includes setting the IP address subnet mask or gateway of UPS RMCARD PDU ATS PDU A PDU is a device which provides power output controls for individual outlets and connected equipment PDU is an abbreviation for Power Distribution Unit SNMP The simple network management protocol It is used by network management systems for monitoring network attached devices for conditions that warrant administrative attention SSL Abbreviation for Secure Sockets Layer SSL is a transaction security standard that provides data encryption server authentication and message integrity TCP UDP Family of
126. ntime will be exhausted and is not sufficient for a complete shutdown When the UPS switches to battery mode due to a power event the battery power will be supplied to Agent computer and all Client computers in order to shut down completely If battery power consumption continues the remaining runtime will be exhausted Agent and all Client computers should start a shutdown procedure immediately 52 CyberPower Reliability Quality Value The Agent postpones the shutdown until the Clients computers completes the shutdowns if the remaining runtime is insufficient for Agent to perform a complete shutdown prior to the UPS turning off the Clients will shut down first to ensure sufficient time for Agent to shut down completely Note This event usually indicates that the Agent and Client risked losing battery power they will have a tolerance of 2 minutes to avoid crashing due to a UPS turning off Battery test is processing A battery test is active in order to verity that battery power can be provided normally Output voltage is being boosted Output voltage is being boosted from a lower level The UPS is receiving utility power with low voltage and raising the voltage to a proper level for operating the connected equipment Output voltage is being bucked Output voltage is being bucked from a higher level The UPS is receiving utility power with high voltage and is lowering the voltage to a proper level for operating the connected equipment C
127. o both input sources are power failure Input is near overload An ATS is near an overload condition The load level is near the safe load threshold for the ATS Input is overload An ATS is in an overload condition The safe load threshold has been exceeded Power consumption is too high Power the specific ATS consumes has been exceeded the high threshold Power consumption is too low Power the specific ATS consumes has been violated the low threshold Shutdown initiated A computer which connects with ATS initiated the shutdown process The computer will shut down or enter hibernation Notification Recipient Please refer to Event Action Recipient section about how to define notifications Settings Please refer to Event Action Settings section about how to configure the detail settings of event actions Logs System Logs The System Logs page in Center provides users logs of recorded details from operations performed in Center The logs can be used for analysis or to determine whether operations have been performed correctly Li CyberPower Reliability Quality Value System Logs Time 2015 0 1 05 01 37 05 2015 0 1 05 01 36 45 2015 0 105 01 31 15 2015 0 1 05 01 30 48 2015 0 105 01 30 11 2014 12 09 07 07 44 2014 12 09 06 41 31 2014 12 09 05 46 32 2014 12 05 01 21 39 Event ATSIPOU 15SMHVIEC 12AT 192 168 26 70 was added Devices 192 168 26 70 tailed to be added UPS Unknown 192 168 26 59 was added
128. o view older logs by changing the page displayed clicking the refresh icon updates the logs displayed in the list Event Logs Logs Event Logs page records the event logs that can be analyzed whether the devices and the system are functioning well Each log records what event occurred of the device Using the paging toolbar helps users to view the other range of the filtered logs backward or forward and update the result according to current filter options Click the Save shortcut at the paging toolbar of the event log table and select CSV or PDF file as the export file format The exported file will be saved in the default download directory of your web browser 116 CyberPower Reliability Quality Value 2015 01 08 02 13 PM 7 Event Logs Filter E Name RMCARD303 PDU 1SSWSFNET PDU ISMHVIEC 12AT POU 1SMHVIEC 12AT RMCARD303 PDUSOSWHVTISATNET POUSOSWHVTISATNET PDUSOSWHVTISATNET POUSOSWHVTISATNET POUSOSWHYVTISATNET PDOUS0SWHVTISATNET PDOUSOSWHYVTISATNET POUZSOSWHVTISATNET PDOUS0SWHVTISATNET POUS0OSWHVTISATNET PDOUSOSWHVTISATNET POU30SWHVTISATNET PDU30SWHVTISATNET POUJOSWHYVTTISATNET PDU30SWHVT 1SATNET PDUSOSWHVTISATNET A 8 Page Time 2015 01 08 01 27 46 PM 2015 01 08 01 27 45 PM 2015 01 05 01 37 36 PM 2015 01 05 01 37 06 PM 2015 01 05 01 31 16 PM 2014 12 18 11 05 22 PM 2014 12 18 10 45 33 PM 2014 12 18 10 10 14 PM 2014 12 18 10 07 30 PM 2014 12 18 09 58 27 PM 2014 12 18 09 5036 PM 2014 12 18 0
129. occur incessantly on each time system starts For example if a network communication lost event final results in system shutdown Client will be aware of communication loss and shutdown system soon Make sure that Client computer is assigned to match the actual outlet connection Computers on NCL outlets will shutdown prior to ones on CL outlets when a power event occurs Follow below steps to avoid the Client shutdown hibernation on each time system boots For Windows Users Press F8 when your computer boots Your system will go to Windows Advanced Options Menu and select Safe Mode option to enter the safe mode Log on to your computer as an administrator Note When your computer is in safe mode you ll see the words Safe Mode in the corners of your monitor Edit the preferences xml file located at lt nstallation_directory gt etc client folder on the Client computer and search the lt shutdown_pause gt tag as below example lt xml version 1 0 encoding UTF 8 gt lt preference gt lt shutdown gt lt shutdown_pause gt false lt shutdown_pause gt lt shutdown gt lt action gt lt oreference gt Change lt shutdown_pause gt value from false to true Save the preferences xml file and restart your computer 123 CyberPower Reliability Quality Value Login the PPBE page to check the setting Note All shutdown or hibernation in safe mode will not take effect by events evoked currently Restart the se
130. of severe level and warning level type support a repeat notification 49 CyberPower Reliability Quality Value Initiated Determines whether to execute a command and sets the delay for the command execution If the event is cleared within the command execution delay the command for this event and the corresponding event will not be executed Duration Sets the estimated time for the command to complete If the event requires the computer to shut down this delay provides time for commands and scripted actions to complete before the shutdown is initiated File Sets a command file to be executed when an event occurs Shell scripts for the command file uses cmd as the filename extension For more information about shell scripts read the detailed description in the default cmd file in the extcmd folder in the PowerPanel Business Edition installation directory Customized shell scripts must be saved in the extcmd folder in the PowerPanel Business Edition installation directory The command file will be listed on the Command File list and can be executed when the power event occurs Note The command file name will be displayed in italics if the command file which had used cannot be found in the extcmd folder The following environment variables can be placed to external commands to identify which event and which stage to be executed EVENT STAGE Indicates what stage of firing event to ex
131. on on Windows A pop up window will be displayed automatically when inserting the PowerPanel Business Edition installation CD Users can click the Install PowerPanel Business Edition shortcut on the pop up window to initiate the installation procedure If the pop up window is not displayed when inserting the CD browse to the CD drive and open the folder which locates at Software Windows and then double click the file named Setup exe to start the installation procedure Use the PowerPanel Business Edition installation CD to complete the installation on the target computer To install follow these steps Click the Next button to start an installation P Setup CyberPower PowerPanel Business Edition Welcome to the CyberPower PowerPanel Business Edition Setup Wizard This will install CyberPower PowerPanel Business Edition on your computer It is recommended that you close all other applications before continuing Click Next to continue or Cancel to exit Setup Cancel Accept the license agreement CyberPower Reliability Quality Value P Setup CyberPower PowerPanel Business Edition Seles License Agreement Please read the Following important information before continuing Please read the Following License Agreement You must accept the terms of this agreement before continuing with the installation ELECTRONIC END USER LICENSE AGREEMENT FOR POWERPANEL BUSINESS EDITION NOTICE TO USER THI
132. on one single virtual machine and then make amounts duplicates The Agent only interacts with one of them Please follow below steps When multiple virtual machines start this may result in duplicating network names Please contact the administrator to resolve this condition first 124 CyberPower 14 15 Reliability Quality Value Stop the PPBE service For Windows users stop the service from Start gt Control Panel gt Administrative Tools gt Services gt PowerPanel Business Edition Service For Linux users use the command service ppbed stop to stop the service Open the preference xml file located at lt nstallation_directory gt etc client Delete the lt uid gt tag as below example lt uld gt 2c779a9a 8 1 8a 4949 a8b9 50535bf26c 1 lt uid gt Start the PPBE service For Windows users start the service from Start gt Control Panel gt Administrative Tools gt Services gt PowerPanel Business Edition Service For Linux users use the command service ppbed start to start the service have downloaded the installer on the Linux from the website The installer cannot be launched Before launching the PPBE installer you must change its access permission on the installer You must have executable permission on the PPBE installer otherwise the message Permission Denied will be displayed Run the below example command to change its permission of the 32 bit installer on 32 bit Linux platfor
133. or passwords HTTPS provides secure identification and encryption HTTPS is usually used for sensitive transactions and PowerPanel Business Edition also provides HTTPS connections to access the web remotely 74 CyberPower Reliability Quality Value Network Security HTTP Secure Secure Level Basic HTTPS Port 53568 SSL Certificates Last Import Result None Last import Date None Settings Network page HTTP Secure PowerPanel Business Edition allows users to change the secure level and port explained below Secure Level Determines which security level to be used to access web interface m Basic Web access is not protected by HTTPS This indicates that the sensitive information may not be protected on the network H Sensitive Only web access including the sensitive information such as password or secret phrase will be protected by HTTPS The Login Event Action Settings Security Login Security Authentication and Security Network pages contain the sensitive information Complete All web access will be over the HTTPS connections HTTPS Port Determines which port to be used over the HTTPS connections The default port is 53568 Once the secure level is changed the new secure level will be taken effect All pages can t be displayed during the duration to restart server After the new security has been changed users will be logged out by Agent and Client automatically Users must login again on t
134. or restart can be initiated on a computer with either Agent or Client installed by going to Shutdown Restart in Computers on Outlets A window will list the computers which can be shutdown or restarted Clicking X will remove that computer from the list and they will not be shutdown restart Note If a PDU is connected to a UPS shutting down computers on UPS outlets will result in shutdown computers in the PDU Shutdown bei Below computers will preform the shutdown ubuntu testing xp testing OK Cancel A confirmation window lists computers able to be shutdown Power Control Power Off Click Power Off and a confirmation window will appear Decide whether to perform an immediate or a sequenced power off then click OK to begin When a UPS or a PDU initiates a sequenced power off computers connected to the UPS PDU ATS that have Agent or Client installed will initiate shutdown prior to the sequenced power off Note An immediate power off will likely result in connected computers losing power Power Off zw vi PDUI5SSWSFNET will power off Are you sure to s H e r perfrom this operation E Power off directly without sequenced delay OK Cancel A confirmation window of a PDU power off operation Power On Click Power On to have the UPS PDU ATS turn on output power Decide whether to turn on output power immediately or after a delay in the confirmation window Click OK to begin 92 CyberPower Relia
135. ored the UPS will delay switching to normal operation from using battery power If the battery capacity is lower than the Low Battery Threshold as power is restored the UPS will switch to normal operation immediately This option can be used to prevent frequent outage due to unstable utility power Restore Action Sets the operating mode after utility power restores If the Bypass option is selected the UPS will enter to bypass mode and supply power from the bypass module to connected equipment when utility power restores If the Online option is selected the UPS will supply power from the UPS modules to connected 32 CyberPower Reliability Quality Value equipment when utility power restores If the Standby option is selected the UPS will be off when utility power restores Bypass Condition The Online UPS series supports the bypass function When the UPS is in bypass mode the utility power is supplied directly to the connected equipment To configure whether the UPS is allowed to enter or remain in bypass mode in select from the following Qualification This configures the qualifications the UPS uses to determine if it will enter bypass mode when a UPS fault or overload occurs WR Valid Volt amp Freq If the utility voltage is in range of the voltage thresholds and the utility frequency is in range of the frequency tolerance the UPS will enter bypass mode Otherwise the UPS will stop supplying output power m Val
136. ors blink normally Click Initiate button to begin an indicator test The details will be reported after an indicator test is complete Last Processing Date The date the last indicator test was performed Load The UPS supplies power to generic equipment and shutdown protected computers that connect to native outlet sockets of UPS or extended PDU The UPS Load page provides detailed information about connected loads and the extended PDU or CyberPower Reliability Quality Value Load Management PowerPanel installed Yes No IP Address 192 168 276 960 Name DSRD100 Location RACK A Contact Torre Tek 1234 Outtet s5 e Fan Control sr Ss L WW es aoe i y wine t stng U lt Dt Vorkstation Rack A im POU 15S Wor JOnt access me piz Goden Cheng 192 168 26 93 Q D2RD100 23 192 168 25 90 UPS Load page Manage Loads Users can manage connected loads that include generic equipment and computers from the Load Management page A UPS and named PDU tabs whose lists contain connected loads All connected loads can be listed with detailed information including the name location contact and what type of outlet the equipment is plugged in from the list Plug a load on UPS or PDU Select the UPS or one named PDU tab click the target outlet from the list and ensure whether the outlet from the Outlet Preview is correct If you want to plug a computer that has been installed PowerPanel Business Edition Client software
137. overloaded Without this enabled the UPS will stop supplying power when overloaded Bypass at Power Off This determines whether the UPS will switch to bypass mode and supply utility power when the UPS is switched off Bypass Frequency Tolerance UPS enters bypass mode due to overload or fault and UPS will detects the bypass frequency If the frequency is out of range UPS will stop supplying output power Battery Prevent Excessive Discharge When the UPS uses the battery to supply power for output a deep discharge with a low load can shorten the battery life If this option is enabled the UPS will stop supplying power after discharging for 4 hours to avoid a deep battery discharge 33 CyberPower Reliability Quality Value Energy Saving When the utility power fails the batteries will start discharging If this option is enabled and there is no output load the UPS will shut down to save battery power after discharging for 5 minutes The UPS will restart automatically and restore output after the utility power is restored Low Battery Threshold When the UPS supplies battery power and the remaining capacity are lower than this threshold the UPS will sound an alarm Battery Pack Type Sets the type of extended battery packs When the UPS is installed the standard battery packs Agent has capability of measurement the runtime according to the capacity of the battery packs The option should be set Standard When the UPS is insta
138. pient page Recipients can be managed as follows Add anew recipient Click the New Recipient to have the blank notification recipient fields or use the data from a selected recipient Enter all required data and click the Add button to add a new recipient to the list Modify the recipient Select the recipient you wish to modify After entering in the new data click the Apply button to complete Remove the recipient Select the recipient to remove from the recipient list and then click Remove to complete the recipient deletion The recipient detail settings and descriptions are explained below Active States if the recipient is active Language The language to which the recipient prefers The notification sent to this recipient uses this language to display content Recipient Name The name of the recipient The recipient name must be unique E mail Address The E mail address of the recipient CyberPower Reliability Quality Value XMPP Account The XMPP Instant Messaging account of the recipient See Event Action Settings for more details about XMPP WLM Account The Windows Live Messenger Instant Messaging account of the recipient Computer Username The computer user account name which is used to receive the windows alert messages Due differences in the Messenger Service of different versions of Windows please refer to the descriptions below m If PowerPanel Business Edition and the recipients are on Windows 2000
139. protocols for the transport and network layers TLS Abbreviation for Transport Layer Security TLS is a cryptographic protocol which provides communication security over the internet TLS and SSL provide data encryption and server authentication for message reliability vMA Abbreviation for vSphere Management Assistant A virtual machine that includes prepackaged software and supported by the VMware Inc allows administrators to run scripts and agents to manage ESXi hosts 133 CyberPower Reliability Quality Value VMware ESXi An enterprise level computer virtualization product offered by VMware Inc It is a component of VMware s larger offering VMware Infrastructure and adds management and reliability services to the core server products Virtual Appliance A virtual machine image is designed to run on a virtualization platform developed by VMware Inc It is intended to eliminate the installation configuration and maintenance costs associated with running complex stacks of software VMware vCenter A vSphere s centralized tool that allows for the management of multiple ESXi servers and virtual machines from different ESXi servers through a single console application Microsoft Hyper V Server A native hypervisor based server virtualization product being offered by Microsoft Corporation ATS ATS is an electrical switch that switches a load between two sources It can switches power automatically to a generator or oth
140. pts HTTP POST to send messages This specification from an SMS provider is required before using the HTTP POST method to deliver messages to SMS providers Select the Using HTTP POST option at the Service Provider field Insert EVENT ACTION PHONE NUMBER as recipient s mobile phone number and EVENT ACTION MESSAGE as the event message content described in the specification and fill in the URL and POST BODY fields The expressions will be replaced by the relevant content before the Agent Client sends a notification to the SMS provider e g URL hittp send sms company com sms POST Body user xxxxxx amp password xxxxxx amp to EVENT_ACTION_ PHONE NUMBER amp text EVENT ACTION MESSAGE Service provider accepts HTTP GET to sends messages This specification from the SMS provider is required before using the HTTP GET method Select the Using HTTP GET option at the Service Provider field Insert the EVENT ACTION PHONE NUMBER as recipient s mobile phone number and the EVENT ACTION MESSAGE as event message s content described in the specification and fill in the UAL field The expressions will be replaced by relevant content before the Agent Client sends a notification to SMS provider e g URL hittp send sms company com sms user xxxxxx amp paSssword XXXXxxx amp to EVENT ACTION PHONE _NUMBER amp text EVENT_ ACTION MESSAGE Service provider accepts E mail to send messages This specification from an SMS provider is required before using the E
141. puter equipment is detached from the UPS PDU ATS on the Power Equipment page this computer equipment will be also removed from the IT Equipment page If a computer equipment is removed from the IT Equipment page this computer equipment will remain on the Power Equipment page IT Equipment Details Details E Summary IT Equipment Name Raser Printer Status Normal Type Equipment Address Location PDU Name PDUI5SSVWSFNET DEMO Status Normal Outlet 2 Summary tab of Details window of printer IT Equipment Name The name of this computer or equipment Status The operating status of this computer or equipment Type Which type this computer or equipment is Either Agent or Client depending on which the computer has installed Equipment if it is generic equipment such as fan cooler Address Indicates the address of this computer or equipment Location Indicates where this computer or equipment is located UPS PDU ATS Name The name of this UPS PDU ATS which supplies power to this computer or equipment Status The operating status of this UPS PDU ATS Outlet Indicates the current outlet which supplies power to this computer or equipment IT Equipment Operations Users can order all computers and equipment to do the following Shutdown Restart 105 CyberPower Reliability Quality Value Select Shutdown or Restart item from the context menu and the confirmat
142. r Server Indicates the selected infrastructure is a vCenter server It may be the vCenter server to which the selected ESXi host or selected virtual machine belongs m Name The name of the selected vCenter server m Address The IP address of the vCenter server m Status Displays the present status of the vCenter server WR ESXi Host Amount The amount of the ESXi hosts of the target vCenter server UPS Displays detailed information of the UPS which is supplying power to the selected infrastructure m Name The name of the UPS m Address The IP address of the UPS WR Outlet Indicates the outlet number and what the bank type of connected outlet m Status Displays the present status of the UPS Note Not each infrastructure provides the same information The information will vary by each infrastructure Settings The Settings tab allows you to configure the connection settings Port Sets the port number for Center to access the vCenter server Username Sets the user name to access the vCenter server or ESXi host Password Sets the password for the user name Attach plugin to vCenter Server Decides whether to attach a vCenter server plug in Note Changing the port user name or password may cause communication loss with Center Power Source of Service Infrastructure Settings 109 CyberPower Reliability Quality Value The Settings tab allows you to connect or disconnect the infrastructure with the target UPS The infrastru
143. rPower Reliability Quality Value WR Host Address This is the address of the VMware ESXi host that will be shut down by the software in the event of a power outage WR Account This is the account name for VMware ESXi host used by PowerPanel Business Edition The account must have root access m Password This is the password for the aforementioned account E mail E mail Activate Gi Yes No SMTF server address example com Secure connection TLS O SSL None Service port 25 Default port 587 sender name ppbe_ user sender E mail address ppbe_usen hotmail com Authentication Yes No Account ppbe user Password soeee Email service Activate Specify whether the Agent Client can use E mail to send an email notification to recipients SMTP server address Configure the SMTP server that will be used to send E mail to a recipient s mailbox Secure connection Sets which secure connection for the SMTP service to sent the E mail Service port Sets the port number for the SMTP service to use Sender name amp Sender E mail address Configure the sender information for the E mail Authentication Configure whether the SMTP server requires authentication or not If authentication is required complete the necessary account and password field Account Sets the account to access the SMTP server Password Sets the password for the account Windows Live Messenger Using Windows Live Messenger Instant Messaging service
144. rase which is used in the PowerPanel Applications PDU and UPS must match Note If the firmware version on the RMCARD202 is earlier than 1 1 you should refer to SNMP Community and SNMP Trap Community sections for the correct configurations SNMP The Center can interact and access device information via SNMPv1 and SNMPv3 Fewer early UPS and PDU models which only accept SNMPv1 demands and newer models which support SNMPv8 can be controlled by Center 118 CyberPower Reliability Quality Value SNMP Protocol User can determine which SNMP protocol to use over the network communication between Client and devices It is recommended to choose Both option because Client attempts on the correct SNMP protocol for device to interact SNMPv1 SNMP Community The Center uses this community to authenticate communication between the PDU and UPS in order to access their information The default community is private By default the UPS PDU ATS uses private as the community with write permission and public with read only permission The community used by the Center to access the UPS PDU ATS must have write permission for an administrative power control SNMP Trap Community The Center uses the community to authenticate the SNMP trap from the monitored PDU and UPS RMCARD The community default is public The IP address of the Center computer must be added to the Trap Receiver list on the Network Trap Notification page of the UPS RMCARD and th
145. rei 82 PICI WEE 84 ROG EE 84 e TEE 84 Beie 84 Using PowerPanel Business Edition Center ccccccccsesssseeeeeeeseeceenseeeeeeeeeeoensnseeeeeseeooesnsseeeseeseooeanes 85 Manageme E 85 Power 1 OUI SI stcrespeaietocmesnncnrnacsancuasaianennantetneimtininsesteeiaraientaiesheesilesttaauanstaesa R SE R EEE EEEE UE 85 Ph ar eu TE E 101 Service Infrastructure ecccccccseeseececcaeeeeeeeccaeusceeecseaseceeecsaeseceeesseaseeeeessauseeeeessaaseeeessaaeeeeessaaeeeeesssaaeeeees 107 EHe Oy CONSID UO NEE 112 A O E 112 STEALL E e a E N E E E PE E AN TNE N E TE NE E E E NE NE E 113 S e E 114 SE 114 Notification Kee VE EE 116 SEET E 116 Beie CNN 116 Se Mi Eo e lt E E N E EA E A TE S A I E A T A E E A E E E T 116 EVON EGOO E 117 SS e EEE E EE E E E E E E E 119 SLEE A AAPEEE ATI NETESE EAE ATA T E NE TE E TE TE 119 LOOM a a A A cab eiela ines aieceosanthemnete 119 PAU ACTING aO eege 119 CyberPower Reliability Quality Value INST ele EE 120 aE o E EE E A E AE E E T E E EeNge 120 OG AE E E N E A EN ANA TNE T TEO N E AE E NE ENE A E 121 ee 121 Beie 121 Technical SUPPONI ae eee ees cree eee aaa eure coe eee ieentieene enrnteecenteneeemmnenses 121 AO ONS Lee e ariane E sack tad Sees cees E T E 121 FPA EE 126 134 CyberPower Reliability Quality Value Introduction This is a new statement PowerPanel Business Edition PPBE software provides comprehensive advanced power management for UPS PDU ATS systems It controls un
146. ress the Reset button for 1 second to reset the uptime of device to have the top priority Do not press the reset button for more than 4 seconds Otherwise it will be recognized as a complete configuration reset demand 192 168 26 118 Available Address A 192 168 268 157 Click to refresh 192 165 26 68 EE 192 168 265 158 192 166 26 76 192 166 26 93 Clicking the refresh button to search all devices again on the local network PDU Address Assigns the network address of the PDU Enter the IP address or use the pull down to show the device list and select a device address from the list Clicking the refresh button the icon with the rotating arrow 45 CyberPower Reliability Quality Value causes to search the network to update the results This option appears when power connection is set from computer to network PDU directly ATS Address This option appears when the power of a computer is configured to connect to an ATS PDU Name Selects the target generic PDU from list After the UPS with Generic PDU of the Power Connection option is selected and entering a UPS address the computer will fetch the list of installed PDU from UPS If the list is empty then you have to install the PDU in UPS Load page of PowerPanel Business Edition Agent This option appears when power connection is set from the computer to a PDU that is an extension power of the UPS which is controlled by PowerPanel Business Edition Agent UPS Outlet
147. ritical equipment should be connect to the NCL outlets to be powered off early This will maximize the battery runtime for critical equipment such as servers on the CL outlets 6 The UPS Load page allows users to establish communication with the Client by assigning the Client s IP address Are there other ways to establish communication Communication can be established by assigning the Agent s IP address on the Device Network Address section on the Power Configuration page in the Client See the Power Configuration for more details about how to establish the communication with the Agent 7 How can I make PowerPanel Business Edition run a program when a particular event has occurred Create a cmd file and save it into the extemd folder of PowerPanel Business Edition installation folder Then write a command to run your own programs into this script file Please refer to the default cmd in the extcmd folder to write your own script 8 am not sure what the IP address of the UPS PDU ATS is How can I obtain the correct IP address Use the Power Device Network Utility tool to help you to find the correct IP address of UPS PDU ATS This device list will list the all CyberPower device s IP address on the local network 9 How do I uninstall PowerPanel Business Edition On Windows go to Start gt Control Panel gt Add or Remove Programs Click the Change Remove button of PowerPanel Business Edition to uninstall the program On
148. rom the context menu Decide whether to restart the outlet Click OK to restart the outlet A computer which has Agent or Client installed will also initiate a shutdown prior to the power cycling Turning off the outlet of a bank or restarting the outlet of the bank will also cause other computers on other outlets to be shut down Locate Select Locate from the context menu The computer uses speakers to generate the audible sounds IT Equipment 99 CyberPower Reliability Quality Value Monitor the status of computers and equipment connected to the UPS PDU ATS Issue orders such as shutdown or restart when the connected outlet is being turned off or turned on Request computers perform a shutdown or a reboot Manage computers and equipment in a group and issue orders to grouped computers or equipment IT Equipment Management eS C Generic Equip HP Printer DJ 4400 Normal 4 QNAP TS 120 Normal 2 QNAP TS 220 Normal Router WBR 520 E Normal 4 Severs Workstations cyberpowersystems co Normal T localhost cyberpowers Normal localhost localdomain C3 Normal localhostlocaldomain C3 Normal IT Equipment page Toolbar The Toolbar provides equipment states and buttons to expand add group or equipment kor al 0 8 Refresh Toolbar of the IT Equipment page Add Group Click this button and Add Group will appear Add Computer Equipment Click this button and t
149. rt PPBE UPS Critical Event critical UPS event occurs UPS Utility power failure Warning UPS Power restored Normal For example when the utility power fails a warning level alarm whose name is PPBE UPS Critical Event will be issued in the Triggered Alarms view under the Alarm tab A related event will be logged in the Events view of the Tasks amp Events tab Note Triggered alarms are visible through the vSphere Client or vSphere Web Client connected to a vCenter server Energy Consumption Statistics Total Today This Month This Year Energy Consumption Statistics page The Statistics page shows the chart how to spend the energy in a specified period and also shows the energy Statistics of the current target node and entire system Each UPS PDU and ATS whose consumption will be logged per hour and each group which contains these UPS PDU and ATS will work accumulating the consumption of data These data which logged the consumption in the past can be gathered to render a chart in a past day a past day a past year and a past decade accordingly Administrators 111 CyberPower Reliability Quality Value will realize how much energy has been spent in a past period Energy can be spent more efficiently and reduce the waste Each selected group UPS PDU and ATS whose statistics of the total and the average power consumption according to the current chart Center will also show the statistics about the tot
150. rust list is a pre defined list of SSL certificates that have been signed by a trusted entity A certificate trust list of PowerPanel Business Edition is used to identify the certificate authority of another one with whom interacts When importing a new SSL certificate this will result in communication loss between the Agent Client and Center As an example when the Client that has been connected with the Agent imports a new SSL certificate the Clint cannot interact with the Agent Users must to add the certificate of Client into the trust list of the Agent manually and thus the Agent considers the Client s SSL certificate valid Users can follow the steps to add the certificate into the trust list Client and Agent for example Place the SSL certificate of the Client as file extension of crt in the lt agent_installation_directory gt jre lib security Switch to the lt agent_installation_directory gt jre lib security directory in the command prompt cd lt agent_installation_directory gt re lib security Run the below command to add the certificate to the trust list lt agent_installation_directory gt jre bin keytool exe import trustcacerts file lt cert_name gt crt alias lt alias_name gt keystore cacerts Enter changeit as the password for the certificate addition Enter y to apply the certificate addition Restart the Agent service to reload the trust list and take effect Refer to How to restart PowerPa
151. rvice to apply new setting from the PowerPanel Business Edition service of the Control Panel Administrator Tools Services For Linux Users Example for Ubuntu Press and hold the Shift key as your computer reboot to enter the GRUB screen Press e key to edit the GRUB command Lookup the commands similar to below examples Append single parameter following the command as root UUIS 67f1 e90f d48b 40a3 9559 6 12cd821e4d1 ro quiet splash single root UUIS 67f1 e90f d48b 40a3 9559 612cd821e4d71 ro quiet splash Press the Ctrl x key or F10 key to restart the boot up process of your Linux Core in the runlevel1 mode single user mode Note These changes are not persistent Any change to the kernel boot options made this way will only affect the next boot and only if you start that boot by pressing either Ctrl x or F10 while still in GRUB edit mode Edit the preferences xml file located at lt Installation_directory gt etc client folder on the Client computer and search the lt shutdown_pause gt tag as below example lt xml version 1 0 encoding UTF 8 gt lt preference gt lt shutdown gt lt shutdown_pause gt false lt shutdown_pause gt lt shutdown gt lt action gt lt preference gt Change lt shutdown_pause gt value from false to true Save the preference xml file file and restart your computer Restart your computer to access the page to check the settings 13 I install the Client
152. s to multiple UPS PDU ATSs equipment and computers on a local network Center should be installed Note Agent and Client cannot be installed on the same computer Which components should be installed l Center 2 Client 3 Agent Please enter a comma separated List of the selected values or Enter for the de fault selection Choose the destination location Nhere should CyberPower PowerPanel Business Edition be installed usr Local ppbe Installation procedure starts to process until the installation is complete Please wait for CyberPower PowerPanel Business Edition configuring Default username and password is admin CyberPower PowerPanel Business Edition may not do hibernation Finishing installation Installation on VMware ESXi and ESX Installation on ESXi Installation must be launched in the vMA vSphere Management Assistant which is also a virtual machine on the ESXi host Agent should be installed on the vMA of ESXi 4 1 or later versions In order to deploy vMA on the ESXi host and install PPBE in the vMA users must install the vSphere Client tool on another remote computer first To download the vSphere Client installer users can enter the ESXi host IP address to access the web page Users can visit VMware website for vSphere Management Assistant Guide document about vMA deployment on VMware ESXi The installer will guide users in completing the installation Refer to Installation on Text Mo
153. station environments as testing environments or to Il Host consolidate server applications Virtual machines run on hosts The same host can run many virtual machines AN e i Se Be vSphere Client Basic Tasks p Power on the virtual machine te Edit virtual machine settings Login the virtual appliance The default username and password are admin In order to perform shutdown accurately you must change the time zone settings of the virtual appliance This can be a direct copy of the time zone file from the usr share zoneinfo folder We assume that the host is located under the Chicago CST zone in Chicago and the time zone can be changed by running the command cp usr share zoneinfo America Chicago etc localtime Installation on XenServer The installer requires root permission to install the PowerPanel Business Edition Mount CD by running mount t iso9660 dev cdrom mnt cdrom as a root user dev cdrom is the CD drive and mnt cdrom will be the mount point Browse the CD drive and run ppbe linux x86 sh command to initiate an installation procedure Installation must be launched on the Dom Refer to Installation on Text Mode section to complete the installation Agent should be installed on the Dom 0 of XenServer 5 or later versions Citrix XenServer 5 0 and later versions support USB device Before installing Agent with the USB or serial connection make sure that the platform running the Agent supports USB
154. suetiatiatisnbanaunheoanced 11 Installation on VMware ESXi and Es 14 Virtual Appliance Deployment ON ESXi wiciissiaccccssiueecdinauaccssoinvedderieneiteriewncicetensstersavedtcedunaciteduvediceicucctenaans 15 AS Te NUON OF E 19 Installation ON Hyper V Server cccccccccssssecccccseseeeecceeeseeececseassceeesseaseceeesseaseceeesseaseceessuaeeeeesseageeeeessaaass 19 Accessing PowerPanel Business Edition 20 LOO HE 21 SUE Ke EE 21 FANS 2 A eo eee a E E N E ee ee A ee ee ee eee eee 22 ET E 22 NS EE 22 Using PowerPanel Business Edition Agent and Client cccccsssssseeeeeeeesseeeeseeesseeeseeeesseeeseoessseesseneees 22 Eege 22 IMMA ANY see tce 2 hertetes E E E eee seesacnteed oes 22 MAO le DEE 23 BI 24 SUE 24 Je Weiden lte BET 29 elle e E 30 Kelter Ter 35 Bee 37 ENOTO I a A E A E E 40 Se 42 Tute dan le BEE 42 So EEEa AE tact EEEE E AT E ace E E E E E EAI E A 44 Evon ACION seere e E E E E E EE 48 CyberPower Reliability Quality Value SI E 48 Notification TASC IONS EE 56 POMONA SS LUNN S sarees nes crete toate eee nde E emacs N Sas enacs E N ENEA TE E N TENE E A On Eola GE 63 EVON E 63 TS FASC OS EE 65 SET E 67 EE 68 COW IM BE 68 TS TG E 70 LO GI D 70 attert EE 72 Kante soode auusthaaiuteutradieneuntGatieunsnden qeuitaduessivsdeneuntiatieandnaueaavitadutesmmadansunbiatdaunsndus qeuitadieomadencunt latices 15 PIG CS rocin aR E E E E EA E E E E A EEE EE E E E R 80 U OFE TE ne 80 Power Equipment EEN 81 B
155. t detail is displayed Click Finish to start the deployment task 4 Deploy OVF Template Ready to Complete Are these the options you want to use E ate Details When you dick Finish the deployment task will be started Name and Location Deployment settings Disk Format OVF file E wa ppbe232_centos_buofix ppbe232_centos ppbe 3z Ready to Complete Download size 662 2 MB Size ondisk 1 5 GB Name ppbe232_cenbos Host Cluster localhost cyberpowersystems comiw Datastore datastorel Disk provisioning Thin Provision Network Mapping VM Network to VM Network Power on after deployment After the deployment task is complete the PPBE virtual appliance will be added into the inventory CyberPower Reliability Quality Value 4 Deployment Completed Successfully src oc Deploying Die 2372 centos Completed Successfully Click Power on the virtual machine to power on the virtual appliance ppbe232_ centos Getting Started Summary Resource Allocation Performance Events Console Permissions close tab X What is a Virtual Machine A virtual machine is a software computer that like a Virtual Machines physical computer runs an operating system and applications An operating system installed on a virtual machine is called a quest operating system Because every virtual machine is an isolated computing environment you Can use virtual machines as desktop or S 2 work
156. t from the context menu of the selected group and a pop up window will appear Pick the computers to shutdown or restart and click X prevent a computer to shutdown or restart at this operation Click OK to begin Power Control Power Off Click Power Off in Power Control from the context menu and a pop up window will appear Click X to exclude a computer or equipment and decide whether to do this operation immediately or in sequence Click OK to turn off output power On specific UPS models turning off one outlet of a bank indicates turning off the whole outlets of this bank An immediate power off operation will result in data loss or system crash on computers due to an unexpected shutdown Power On Click Power On from Power Control in the context menu and a pop up window will appear Click X to exclude a computer or equipment and decide whether to do this operation immediately or in sequence Click OK to turn on output power Power Cycle Click Power Cycle in Power Control from the context menu and a pop up window will appear Click X to exclude a computer or equipment and decide whether to do this operation immediately or in sequence Click OK to start the power cycle A power cycle operation may cause other computers to be shutdown on this bank IT Equipment Management IT equipment can be a computer which has Agent or Client installed or generic equipment which is only being provided power Only computers and eq
157. that they are recorded in the virtual machine a ease and will be connected when the virtual machine powers on if the device is present and available 130 CyberPower Reliability Quality Value Select USB Device item and click Next to proceed GI Add Hardware Device Type What sort of device do you wish to add to your virtual machine Device Type USB Device Ready to Complete ve S Serial Port parallel Port Gl Floppy Drive CD DVD Drive Ga LISA Cont er unavailable ae PCI Device available Ethernet Adapte Hard Disk KA SCSI Device Select the USB Device of the target UPS which is connected with vMA Click the Next button to finish Add Hardware Select USB device Which USB device do you want to use Device Type vMotion Support USB Device Ready to Complete Select the host USB device below Description Choose the type of device you wish to add Information This device can be added to this Virtual Machine a EE l Support vMotion while device is connected 131 CyberPower Reliability Quality Value Note In order to make sure that USB device of the target UPS can connect to vMA after a USB controller is added it is strongly recommended to upgrade the virtual hardware to the latest version prior to adding a USB controller and a USB device See How do upgrade the virtual hardware version of vMA for details 18 How dol upload the installer to vMA 19 Login the v
158. the correct PDU outlet Click OK to establish the communication If Client connects with a generic PDU that is a power extension from the UPS the Power Connection should be set UPS with generic PDU Enter the IP address of UPS choose the according PDU model and assign the correct PDU outlet Click OK to establish the communication Note A generic PDU is a PDU that have no network function If Client connects with an ATS the Power Connection should be set ATS first Enter the IP address of ATS and assign the outlet Users should know whether ATS is being supplying power by any UPS to realize how to configure the detail WR fthe ATS is a power extension from the two UPS enter the IP address of UPS individually Click OK to establish the communication 46 CyberPower Reliability Quality Value UPS ATS UPS 1 OUT Powel i put ervey Network Communication m lf the ATS is a power extension from the one UPS enter the IP address of UPS for one power source and another power source should be set None Click OK to establish the communication input Power Output Power casaca Network Communication m fthe ATS is not the power extension from any UPS the IP address of UPS for two power sources should be set None Click OK to establish the communication mmm OUT Powe utput Power sessa Network Communication Troubleshooting Inability to Communication 47 CyberPower
159. the Agent Client can send an instant message to another user who has a WLM account Users must provide a unique WLM account as a sender and assign another one as a receiver on Event Action Notification Recipient page Windows Live Messenger Activate Yes No Account ppbe_user hotmail ce Password Apply Verity Windows Live Messenger service 59 CyberPower Reliability Quality Value Activate Specify whether the Agent Client can use the Windows Live Messenger service to send an instant message to recipients Account Sets the account to access the Windows Live Messenger service Password Sets the password for the account XMPP Instant Messaging The XMPP Extensible Messaging and Presence Protocol is an open protocol for instant messaging Users can setup the configuration to receive instant messages when an event has occurred Users may contact a network administrator to verify if there is a XMPP Instant Messaging server in the network If there is no XMPP Instant Messaging server Google talk service can be used Google Talk software can be downloaded and installed or Gmail can be used to receive event notifications via Google Talk A local network XMPP Instant Messenger server can be setup by downloading open source XMPP Instant Messenger server software such as Openfire More server software information can be found on XMPP server software list AMPP Instant Messenger Activate Yes No Sever address t
160. the agreement E Back Next gt Cancel Choose the component If one single computer is connected to the UPS directly via a USB or serial connection Agent should be installed If the computer is powered by a UPS already connected to an Agent has a remote management card installed or is connected to a PDU Client should be installed If the administrator requires simultaneous monitoring and access to multiple UPS PDU ATSs equipment and computers on a local network Center should be installed Note Agent and Client cannot be installed on the same computer Setup CyberPower PowerPanel Business Edition aay iF Select Components Which components should be installed Select the components you want to install clear the components you do not want to install Click Next when you are ready to continue Center Client e O Agent e lt Back Next gt Cancel Choose the destination directory 12 CyberPower Reliability Quality Value Setup CyberPower PowerPanel Business Edition Select Destination Directory Where should CyberPower PowerPanel Business Edition be installed Select the folder where you would like CyberPower PowerPanel Business Edition to be installed then click Next Destination directory Browse Required disk space 62 1 MB Free disk space 6 176 MB Back Next gt Cancel Click the Finish button to complete the insta
161. the power event of UPS or PDU the correct connection type the address and connected outlet must be assigned properly in the Power Configuration page Configuration Device ower Connection UPS with Network PDU v UPS Address 192 168 26 118 sl f b eg PDU Address 192 165 265 165 PDU Outlet SA identify Connected Cancel Power Configuration page Network communication between a computer and UPS or PDU can be established by assigning the correct power connection address of UPS or PDU and a computer connected outlet of UPS or PDU The details are described as following Power Connection Assigns the actual power connection how a computer connects to UPS or PDU The power connections include as below m UPS Indicates the computer is plugged in one single UPS 44 CyberPower Reliability Quality Value ATS Indicates the computer is plugged in an ATS Network PDU Indicates the computer is plugged in one single PDU with network function UPS with Network PDU Indicates the computer is plugged in a network PDU which is a power extension from the UPS WR UPS with Generic PDU Indicates the computer is plugged in a generic PDU which has no network function and is a power extension from the UPS UPS Address Assigns the network address of the UPS Enter the IP address or use the pull down to show the device list and select a device address from the list Clicking the refresh button the icon with the
162. thin the notification delay the notification of the occurrence and the event cleared notification will not be sent Repeat Determines whether to send one additional notification after the initial notification Only events which are of severe level and warning level type support a repeat notification Shutdown for Infrastructures Initiate a shutdown sequence when an event occurs A shutdown sequence Is only initiated by events specific for the target ESXi host 113 CyberPower Reliability Quality Value Initiated Determines whether to request the target ESXi host to be shut down and the delay before initiating the shutdown sequence The shutdown will be canceled if the event is cleared during this delay time The minimum delay time to initiate shut down is based on the time set for the execution of the notification to complete This includes the notify delay time Note The Center will use the Shutdown for Infrastructure setting of each event as the default shutdown delay time for each according event listed on the Event Action tab of the Power Source dialog in the Service Infrastructure page Refer to Event Action section for further details Event List The Event List displays power events The events are divided into below categories System Power consumption is too high Power system consumes has been exceeded the high threshold Power consumption is too low Power system consumes has been violated the low thr
163. to Check the UPS model and determine to which series your UPS belongs If the model name conforms to the format of OLxxxxRMXL OLxxxx it belongs to Smart App Online series 127 CyberPower Reliability Quality Value If the model name conforms to the format of PRxxxxLCDRM PRxxxxLCDRT PPxxxxSWRM or PPxxxxSW it belongs to Smart App Sinewave series If the model name conforms to the format of ORxxxxLCDRM or ORxxxxLCDRT it belongs to Smart App Intelligent LCD series If the model name conforms to the format of OPxxxx or CPSxxxxAVR it belongs to Smart App AVR series ifthe model name conforms to the format of OLxxxxTEXL or OLxxxxEXL M it belongs to Paragon Tower series If the model name conforms to the format of PRxxxxELCDRT or PRxxxxELCDRT XL it belongs to Professional Rack Mount LCD series If the model name conforms to the format of PRxxxxE it belongs to Professional Rack Mount series If the model name conforms to the format of PPxxxxE it belongs to Professional Tower series If the model name conforms to the format of ORxxxxELCD it belongs to Office Rack Mount series If the model name conforms to the format of OPxxxxE OPxxxxTE OPxxxxUE and OPxxxxUTE it belongs to Office Tower series 17 How do add USB connection to vMA vSphere Management Assistant on VMware ESXi for Ag
164. to add groups add devices or expand all groups 84 CyberPower Reliability Quality Value Add Group Click this button and the Add Group dialogue box will appear Add Device Click this button and the Add Device dialogue box will appear QB Expand All This button will expand all groups The other four icons indicate the amount of monitored devices that have had severe level or warning level events occur the numbers of devices that have lost communication with Center and the number of devices that are normal Indicates severe level power events such as Runtime is insufficient Indicates warning level power events such as Utility power failure Indicates the devices which have lost communication with Center Center cannot monitor or control computers and equipment when communication is lost Indicates the total power consumption of the entire system exceeds the high threshold Indicates the total power consumption of the entire system violates the low threshold Node Components Each node has a name and an icon indicating what type it is A UPS PDU ATS node provides detailed information about what power events have occurred and what the current status is A context menu for each node is available by clicking icon This allows users to view detailed information such as Summary or Status and request operations such as Shutdown or Restart A menu item becomes disabled when this operation is
165. to apply the same setting users can click Export button to export all configuration to the profile The profile will be exported as a zip file and save to the assigned location Agent will export the below power configuration and system settings to the profile Detailed configuration for UPS Detailed settings of each event recipient and action Preferences and security settings Client will export the below power configuration and system settings to the profile Detailed configuration with power device Detailed settings of each event recipient and action Preferences and security settings Organize an Import Importing the profile will reduce the duplicate steps during mass deployment For each computer running Agent or Client users click the Import button to apply the same profile When a profile is imported the content will be verified to determine whether can be applied One profile cannot be applied to each computer completely Not all settings and configuration are applicable to each Agent or Client For example when Agent attempts to import the profile exported by Client or another Agent which is connecting with different UPS the imported profile cannot be applied completely Import Profile on Installation PowerPanel Business Edition installer has capability to import a profile in unattended installation mode In order to reduce the interaction with users the installation will be launched in unattended mode
166. to other power noise and distorted conditions Voltage The voltage of the utility power supplied to the UPS Frequency The frequency of the utility power supplied to the UPS 2o CyberPower Reliability Quality Value Current The current of the utility power supplied to the UPS Power Factor The radio of the real power flowing to the UPS to the apparent power of utility power In an UPS system a UPS with a low power factor draws more current than a UPS with a high power factor for the same amount of useful power transferred Bypass Status Displays the present status of bypass circuit In bypass mode the UPS will provide the power from bypass input to the connected equipment directly m Normal The power quality of bypass circuit is normal Blackout There is no input power being supplied in bypass circuit Over Voltage The input voltage of bypass is higher than an acceptable threshold Under Voltage The input voltage of bypass is lower than an acceptable threshold Frequency Failure The frequency of bypass is out of tolerance Power Failure The power of bypass is not qualify due to other power noise and distorted conditions Wrong Phase Sequence The sequence of phases in bypass is different than utility input Overload Output power consumption exceeds the power rating of UPS Extended Overload The duration of overload has expired Voltage The voltage of the bypass supplied to the UPS Current The c
167. to select which input source to be preferred to use Group Management UPS PDU ATSs can be grouped for easy management Orders can then be issued to multiple devices in a group CyberPower Reliability Quality Value Add Group Click Add Group on the toolbar to create a new group kalit t Add Group button on toolbar You can also add sub groups in the context menu of a selected group Enter the new group name and click OK button to add a new group Move Group Select the group you wish to move and select Move in the context menu Select the target group from the list in the Move Group window After selecting the target group click OK to move the group Remove Group Choose a group and select Remove from the context menu The Remove window will open click OK to remove this group Removing a group will not remove the sub groups or the UPS PDU ATSs belonging to this group These items will be moved to the main group Rename Group Choose group and select Rename from the context menu The Rename Group window will appear and requires new group name to replace origin one Enter the new group name and click When a group has been deleted the sub groups and devices will be moved to main group Note that a duplicate group name is not allowed Group Details 94 CyberPower Reliability Quality Value Details a Summary Group Name Block B Statistics Normal 18 Severe 1 Warning 4 Untouche
168. ttempt to discover the source code of the Software Although you may customize the installer for the Software as documented on the CyberPower PowerPanel Business Edition Disk e g installation of additional plug in and help files you may not otherwise alter or modify the installer program or create a new installer for the Software CyberPower Reliability Quality Value 4 No Warranty The Software is being delivered to you AS IS and its supplier makes no warranty as to its use or performance THE CYBER POWER SYSTEMS USA INC AND ITS SUPPLIERS DO NOT AND CANNOT WARRANT THE PERFORMANCE OR RESULTS YOU MAY OBTAIN BY USING THE SOFTWARE OR DOCUMENTATION THE CYBER POWER SYSTEMS USA INC AND ITS SUPPLIERS MAKE NO WARRANTIES EXPRESS OR IMPLIED AS TO NONINFRINGEMENT OF THIRD PARTY RIGHTS MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE IN NO EVENT WILL THE CYBER POWER SYSTEM INC OR ITS SUPPLIERS BE LIABLE TO YOU FOR ANY CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES INCLUDING ANY LOST PROFITS OR LOST SAVINGS EVEN IF THE CYBER POWER SYSTEMS USA INC REPRESENTATIVE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR FOR ANY CLAIM BY ANY THIRD PARTY some states or jurisdictions do not allow the exclusion or limitation of incidental consequential or special damages or the exclusion of implied warranties or limitations on how long an implied warranty may last so the above limitations may not apply to you 5 Governing Law
169. ttery replacement If this date has not been set it is recommended that this date should be set immediately The battery lifetime varies by UPS models Once set the software will alert the customer when the battery age has reached the lifetime NCL Outlet The amount of the Non Critical Load outlets LCD Firmware Version The firmware version of the LCD screen on the UPS USB Version The version of the USB chipset on the UPS Extended Battery Pack The amount of extended battery packs connected to the UPS Installation Place Clicking the Find it button will ask alarm to beep or indicators to blind in order to inform users of the location This helps users to identify the specific UPS at installation sites with multiple UPS units Configuration The UPS Configuration page allows for customized UPS configurations to meet specific operational requirements UPS Configuration Utility Power Failure Condition High Voltage Threshold 143 Voit Low Voltage Threshold 3 Voit Battery Low Battery Threshold Extended Battery Pack System Cold Start Enabled Utility Power Failure Alarm Disabled NCL Outlet Turn Off Threshold Turn Off Delay Tum On Delay UPS Configuration page of a PR1000LCDRTXL2Ua Supplied Power Voltage Sets the output voltage which is supplied to the connected equipment 30 CyberPower Reliability Quality Value Frequency Working Mode Smart App Online series supports two frequency mo
170. ty voltage Test A battery test is processing Batteries can have the following states when UPS is operating Fully Charged Batteries are at 100 capacity UPS PDU ATSs have the following states according to their current load No Load There is no output load GG Low Load The PDU is in a low load condition Normal The output power is normal CyberPower Reliability Quality Value Near Overload The PDU is near the overload condition Overload Output consumption of equipment exceeds the rating load on UPS or the PDU is In an overload condition PDU also have a state to indicate whether outlet is turned on or off e Indicates this outlet is turned on o Indicates this outlet is turned off ATS have the following states on functioning D ATS uses this input source as current source and this source is normal ATS uses this input source as redundant source but this source is normal Be ATS uses this input source as current source and this source is power failure Y ATS uses this input source as redundant source but this source is power failure The sensor on the UPS PDU ATS has the following states according to the environment temperature A Normal Indicates the temperature measured by the sensor is in a predefined normal range Overheated Indicates the current temperature exceeds the high temperature threshold Undercooled Indicates the current temperature violates the low temperatur
171. ty voltage if it is in range of thresholds or the utility frequency is within 3Hz of the utility frequency If the utility voltage or the utility frequency exceeds thresholds the UPS will supply battery power to its loads lf this threshold is set to 10 and the current utility voltage is 120 V the UPS will enter bypass mode as long as the utility voltage within the range of 108 V 132 V Once the voltage threshold is exceeded the UPS will supply battery power to its loads Caution Once the UPS is allowed to enter the Fixed mode Generator Mode or Manual Bypass when the UPS is in the ECO mode the UPS will leave ECO mode Users can configure exclusive days and exclusive time to for UPS when to not enter ECO mode WR Exclusive Days Sets the days for UPS not to enter ECO mode m Exclusive Time Sets the time period for UPS not to enter ECO mode Power Failure Condition When the utility power exceeds specific thresholds the UPS will supply battery power to the connected equipment Utility Voltage Upper Lower Bound Before utility power is provided to the UPS the UPS will detect whether utility voltage exceeds the threshold If utility voltage exceeds the threshold the UPS will supply battery power to the connected equipment Output Voltage Upper Lower Bound Before the UPS uses utility power as its output power the UPS will detect whether utility voltage exceeds the threshold If the utility voltage exceeds the threshold the UPS will
172. ue to insufficient time for the off delay setting of PDU outlet 1 Configure the off delay setting of PDU outlet 1 now Ea Shutdown type Shutdown The Client will warn users there is insufficient time for a complete shutdown in the PDU Shutdown type This setting will soecify the manner in which the Agent Client computer is shutdown The options are Shutdown or Hibernation The Hibernation option is only visible on operating systems and hardware that support hibernation When the Agent Client shuts down the hosted computer using a Shutdown any unnamed files will be saved automatically in a folder named Auto Saved in the My Documents folder Save opened file amp log off When a power event occurs the computer will shut down in minutes This setting is used to determine whether to save open files on desktop and then log off before the computer is shutdown Also turn off UPS This setting is used for Agent to determine whether to turn off the UPS after the Agent and all Client computers are shut down completely If Yes is checked the UPS will be turned off after the Agent computer shutdown The output power supplied to all equipment will also be turned off If users wish that all equipment can continue being supplying power by the UPS after the Agent computer shutdown this setting should be checked No VM Host In VMware ESXi host root permission is required and a host address must be specified in order to initiate a shutdown 58 Cybe
173. uipment whose power devices are monitored by Center have the following options Add Computer Equipment Click Add Computer Equipment button on the toolbar to display the Add Computer Equipment window Add Computer Equioment button on toolbar 103 CyberPower Reliability Quality Value Select the Add Computer Equipment item from the context menu of any group to display the Add Computer Equipment window Power Control Rename Move Remove Expand All Details Add Computer Equipment item on the context menu Select the computers or equipment you wish to add and click OK Add Computer Equimpment 2 List of computers and equipments E Name Location IP Address Belong Device Contact D7RD107 CYBERPOWER 192 168 24 17 DfRDID Adminitrator E xptesting CYBER 192 168 24 57 PDUISSWEF CT esx vMA CYBERPOWER 192 168 110 139 OR1000LCD root Cancel Add Computer Equioment window Move IT Equipment Select Move from the context menu A pop up window will appear and you will have to assign a target group Click OK to move to the target group Rename IT Equipment Select Rename in the context menu A pop up window will appear and you must enter a new group name to replace the original one Click OK to apply Remove IT Equipment 104 CyberPower Reliability Quality Value Select Remove in the context menu A pop up window will appear Click OK to delete the selected item Note If a com
174. unction normally If this option is enabled the UPS will be forbidden to enter bypass mode to protect the powered equipment Caution If this option is enabled the UPS can t function in the Manual Bypass mode LCD Back light Saving When no UPS button is pressed or no power event occurs during this delay the LCD screen will be turned off Wiring Fault Detecting If this option is enabled the UPS will detect if the UPS wiring is not grounded or reversed It is recommended to assure the UPS wiring has ground connection first This option should be enabled if the UPS wiring has ground connection Dry Relay Function This configures the power condition for the UPS dry relay to function when the selected condition occurs Refer to UPS manual for further information about advanced UPS dry relay utilization The Dry Relay Function provides the following power conditions 34 CyberPower Reliability Quality Value Utility Failure The utility power fails and the UPS is using the battery power Low Battery The battery capacity is low and cannot support the connected computers if they require a shutdown Alarm The UPS is issuing an audible alarm due to a warning event such as Overload Bypass The UPS has switched to bypass mode due to an overload or UPS fault UPS Fault The UPS may be malfunctioning due to an internal problem such as an inverter fault bus fault or overheating Redundant Quantity Sets the quantity of UPS modules to be power re
175. up or power equipment spent exceeds the threshold the High power consumption event will occurs Low Threshold When the power consumption which the group or power equipment spent violates the threshold the Low power consumption event will occurs Event Action An event is generated when the UPS PDU ATS encounters specific power conditions The Center can monitor multiple power devices and computers and can be configured to respond to specific events and notify users based on the event In the event of power devices and computers the Center can send the notification in response to events from the devices and computers Events When an event occurs Center can notify administrators which device occurred event The Event Action Events page lists events and divides these events into several categories Each event is allowed to configure the individual notification settings The severity of each event is marked by a symbol After selecting an event the event will become configurable Configure all of the action settings for the selected event and apply to save the settings Use these parameters to configure actions for individual events Notify The administrator can be notified when an event occurs See Event Action Notification Recipient page for more details about the notification methods and recipient assignment Initiated Determines whether to send a notification or not and sets the notification delay If the event is cleared wi
176. ur when the load consumption are exceeded to use extra power that belong to redundant power some UPS modules are faulty or manual shutdown UPS is abnormal UPS is working abnormally due to power conditions that include as below WR Input is no neutral The neutral wiring is not connected well WR Site wiring fault The wiring is reversed or not grounded UPS is fatal abnormal UPS is working abnormally due conditions includes as following list that may cause UPS shutdown and no longer supply power soon or even immediately Output overload Power consumption exceeds the power rating of UPS If the overload is sustained the UPS will be stopped from operation WR Bypass overload Output is overloaded in bypass mode 53 CyberPower Reliability Quality Value HR Module overload One of UPS module is If the UPS module overload is sustained the UPS module will be protected from operation Output short circuit Outout circuit is shorten and causes UPS to stop supplying output power Module rectifier overheats The internal temperature of one module rectifier exceeds the normal rating Module inverter overheats The internal temperature of one module inverter exceeds the normal rating Module inverter protected A module inverter has been protected and stops operating The module inverter may be faulty or fatal abnormal WR Reversed battery connection The connection between UPS and battery is wrong on electrical polarity m Bypass phase s
177. urrent of the bypass supplied to the UPS Frequency The frequency of the bypass supplied to the UPS Power Factor The radio of the real power flowing to the bypass to the apparent power of bypass In an UPS system a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred Output Status Displays the present status of the output power the UPS is supplying to connected equipment WR Normal The output power is normal m Bypass The UPS has switched to bypass mode and the utility power is being supplied directly to the connected equipment bypassing the UPS circuitry Note Bypass mode is only applicable in Online Series UPS units No Output There is no output from the UPS The UPS is switched off Short Circuit There is a short circuit on the UPS output This causes the UPS to stop supplying output power Boost The utility voltage is below the regular voltage range The UPS is increasing the output voltage closer to normal Buck The utility voltage is beyond the regular voltage range The UPS is decreasing the output voltage closer to normal WR Overload The present load exceeds the load threshold of the UPS Remove some equipment from the UPS to reduce the load 26 CyberPower Reliability Quality Value ECO Mode On line UPS enters Economy mode The UPS will enter bypass mode according to thresholds for input voltage Once the utility voltage e
178. verheat The temperature exceeds the normal temperature threshold Bypass Fault The bypass module of UPS has been malfunctioned Bypass Fan Fault The fan of the bypass module has been malfunctioned Module Failure One of UPS modules is no more normal and offline Unable Recover UPS fails to recover to line mode from bypass on occurred overload condition in past one hour Temperature The present internal temperature of the UPS It is displayed in both Celsius C and Fahrenheit F Maintenance Break Displays the present operating status of maintenance break Note When the UPS needs maintenance or repair the load can be transferred to maintenance bypass without interruption and the power module can be removed for maintenance E Opened The UPS is in maintenance bypass mode m Closed The UPS is not in maintenance bypass mode Module Status Displays the present operating status of each UPS module WR Normal The module is operating normally Offline The module is not installed Rectifier Fault The module rectifier is faulty and stops output power Inverter Fault The module inverter is faulty and stops output power Inverter Protected The module inverter has been protected and stops operating 28 CyberPower Reliability Quality Value Rectifier Overheat The internal temperature of module rectifier exceeds the normal rating Inverter Overheat The internal temperature of module inverter exceeds the normal rating
179. verify that the data are matched After the Enabled of Endpoint Agent option is enabled click Apply to establish the connection Children List The Agent that has joined into the EnergyWise network will become the endpoint member and can be divided into several nodes in children list Each node has individual attributes for Cisco switch to manage the power usage These attributes describes as following Name Defines the device identity for which query the results are filtered Role Defines the function which is based on the business or deployment context Keywords Defines the description for this device for which query results are filtered Importance The device rating which is based on the business or deployment context Agent is annotated as the UPS Base node and UPS node indicates the UPS unit According to outlet function of the UPS the outlet bank will be managed as CLBank node and NCLBank node Due to limitation of UPS Cisco switch can only control NCLBank node to turn on or turn off Power The content in this section is only applicable to the Client The Client can interact with a UPS or a PDU through a network interface If the UPS has no remote management card the Agent can be installed on a single computer which is using a USB or a serial connection directly to the UPS in order to establish the network connection to the Client Information 42 CyberPower Reliability Quality Value Power Information
180. ware You may make and distribute unlimited copies of the Software including copies for commercial distribution as long as each copy that you make and distribute contains this Agreement the CyberPower PowerPanel Business Edition installer and the same copyright and other proprietary notices pertaining to this Software that appear in the Software If you download the Software from the Internet or similar on line source you must include the copyright notice for the Software with any on line distribution and on any media you distribute that includes the Software 2 Copyright and Trademark Rights The Software is owned by the Cyber Power Systems USA Inc and its Suppliers and its structure organization and code are the valuable trade secrets of its Cyber Power Systems USA Inc and its suppliers The Software also is protected by United States Copyright Law and International Treaty provisions You may use trademarks only insofar as required to comply with Section 1 of this Agreement and to identify printed output produced by the Software in accordance with accepted trademark practice including identification of trademark owner s name Such use of any trademark does not give you any rights of ownership in that trademark Except as stated above this Agreement does not grant you any intellectual property rights in the Software 3 Restrictions You agree not to modify adapt translate reverse engineer decompile disassemble or otherwise a
181. xceeds thresholds the UPS will supply battery power to its loads Users can configure exclusive days and exclusive time to for UPS when to not enter ECO mode Manual Bypass The Online UPS enters Manual Bypass mode due the Manual option being enabled The UPS will be forced to provide utility power to its equipment Insufficient Inverter Power There is no enough capacity of the inverter s power UPS cannot back to line mode from bypass mode Redundancy Lost The quantity of UPS modules has no enough power to be complete redundancy UPS has no complete fault tolerant ability EPO The function of EPO Emergency Power Off has been activated UPS output power was turned off Voltage The output voltage that the UPS is supplying to the connected equipment Frequency The output frequency that the UPS is supplying to the connected equipment Load The power draw of the connected equipment expressed as a percentage of the total load capacity This is displayed as watts on some UPS models Current The output current of the UPS which is supplying to connected equipment Active Power The capacity of the circuit for performing work in a particular time Reactive Power Reactive power is needed in an alternating current transmission system to support the transfer of real power over the network In alternating current circuits energy is stored temporarily in inductive and capacitive elements which can result in the periodic reversal of th
182. y Previous day Nextday Thatday Time 12 00 AM 44 00PM Le All Duty On Duty Off Weekday W Sun Mon Tue F Wed F Thu F Fri F Sat All Working Rest Max logs 100 Filter pane on Logs Status page Days Selects the day s for the status records to be displayed The dropdown menus next to the Days setting can be used for additional preconfigured filters Time Selects the time range of the status records Weekday Choose the days of the status records Max Logs Indicates the maximum number of status records that will be displayed Settings The Logs Settings page allows for the ability to configure the log options Click the Apply button to save the settings or remove all logs CyberPower Reliability Quality Value Logging Settings Event Logging Entry Expiration 1 week e Ciear All Logs Yes Now o No Status Recording Enabled O Yes No Recording Interval 10 min Entry Expiration 1 week e Clear All Records Yes Now o No Logs Settings page in the Agent Event Logging Entry Expiration This option specifies how long the log files will be retained Clear All Logs When this option selected with Yes Now all event logs will be removed immediately after clicking Apply The log clearing is permanent and once applied the log files cannot be recovered Log to Event Viewer Determines to log events to Event Viewer additionally Users can launch the Control Panel gt Administrat
183. y If the Agent never connects with any UPS this function is disallowed to be activated Power Equipment CyberPower Reliability Quality Value Power Equipment Preference Auto Configure Yes Prevent Early Of No In order for Client to operate properly with the power device device options can be configured in Client Auto Configure Any time the IP address of the power device is changed the Client will lose communication with the power device If this option is checked the Client will scan the network and automatically acquire the new IP address of the power device Prevent Early Off When the Client detects that the PDU outlet which is powering the Client computer is going to be shut off the Client will prepare to shut down the hosted computer If the necessary shutdown time of the Client computer is more than the delay off time of the outlet the Client will stop the computer shutdown and signal the PDU to cancel to outlet turn off Profile Profile Import Export Organize an import Organize on Export Export 81 CyberPower Reliability Quality Value In order for administrators to do mass deployment Profile page allows to export all power configuration and system settings from the target computer Each computer running PowerPanel Business Edition can import this profile to apply the same power configuration and system settings Organize an Export In order to let lots of computers
184. y Authentication page in Client If the Client establishes communication with below devices refer to PowerPanel section for further details PowerPanel applications such as Agent or Center RMCARD whose model name is RMCARD302 RMCARD301 RMCARD203 or RMCARD202 71 CyberPower Reliability Quality Value PDU whose model name is aside from PDU20SW8RNET or PDU15SW8RNET If the Client doesn t establish communication with the aforementioned UPS and PDU refer to SNMP SNMPv1 and SNMPv3 sections for further details PowerPanel Secret Phrase The Secret Phrase is used to create secure network communications between PowerPanel Applications such as Client and Agent Client and UPS RMCARD or Client and PDU The default phrase is powerpanel encryption key The Secret Phrase can be configured on the Security Authentication page in the Agent and Client or on the System Security page in the PDU and UPS RMCARD web The Secret Phrase which is used in the Client and devices must match UPS Remote Management Summary UPS Logs Security User Account Login Session Date amp Time Timeout 3 minute s Identification Security Event Action SMTP Server Cancel E mail Recipients Authentication Secret Phrase powerpanel enciyption key Trap Receivers Clients Shutdown TCP IP HTTP Service SNMP Service FIP Service Preference About Secret Phrase on the System Security page in the UPS RMCARD202 web Note If

Download Pdf Manuals