Home

LUMENTO X3 RGB - Eib Shop Russia

image

Contents

1. 23 Zennio LUMENTO X3 RGB With multiplication 9 On Color sets the colour desired in the LEDs during the ON state Either a predefined colour see Table 2 or a custom colour by manually configuring each of the RGB colour components can be selected 2 On Type sets the dimming type to be applied during the timed switch on of the LED module being the possible options At once Smooth 1 and Smooth 2 See section 3 2 for the parameterisation of the dimming types 3 3 5 FLASHING This function allows executing ON OFF ON OFF sequences in the LED module where it is possible to parameterise the length of the ON OFF stages Moreover the number of repeats can be set by parameter as well as the luminosity for the on state and the final luminosity of the LEDs after the last repetition The intermittence will start when LUMENTO X3 receives a 1 through the Flashing object and stops after executing all the configured repetitions endless repetition is possible by setting the value 0 in the corresponding box as shown later It is possible to stop the flashing at any time by sending the value O through the Flashing object or by sending any other control order that affects the output like an on off a sequence etc If during the flashing execution LUMENTO X3 receives a http www zennio com Technical Support http zennioenglish zendesk com 24 Zennio LUMENTO X3 RGB new
2. Zennio LUMENTO X3 RGB 9 Start up permits selecting a custom start up state after a bus failure or an ETS download reset for the LED module connected to the device as well as sending the status objects to the KNX bus immediately or after a delay 9 Error identification detection of anomalous situations affecting the correct behaviour of the device external voltage errors and overheating errors http www zennio com Technical Support http zennioenglish zendesk com 9 Zennio LUMENTO X3 RGB 3 ETS PARAMETRISATION To begin with the parameterisation process of LUMENTO X3 it is necessary once the ETS program has been opened to import the database of the product LUMENTO X3 RGB application program Next the device should be added to the project where desired And then one right click on the device will permit selecting Edit parameters in order to start the configuration 3 1 DEFAULT CONFIGURATION This section shows the default device configuration the parameter edition starts from 1 New Area mjo Dimming 4 bits dimmer ctrl 4 bit eB 11 ITE e T10 Precise Dimming 1 byte dimmer ctrl 1 Byte gt 4 111 LUMENTO G 1 n Off 1 0n 1 bit a nni On Off 0 Off 1 0 ER 9 Dimming 4 bits dimmer ctrl 10 Precise Dimming 1 byte dimmer cl 29 Dimming Speed 1 0 Min Speed 100 Max Speed 1 Byte EE 11 On Off 0 Off 1 On E30 Dimming Speed 2 0 Min Speed 100 Max Speed 1 Byte TE 29 Dimming Spe
3. 255 0 14 13 Red 255 0 0 15 14 Red Pink 255 0 77 16 15 Red Dark 102 0 0 17 16 Red Magenta 255 0 255 18 17 Red Fuchsia 255 26 51 19 18 Yellow 255 255 0 20 19 Orange 255 51 0 21 20 Lilac 255 128 128 22 21 Purple 170 0 25 BJ Table 2 Predefined colour palette http www zennio com Technical Support http zennioenglish zendesk com 18 Zennio LUMENTO X3 RGB 9 Color Shift a 1 bit object that lets the user trigger an automatic scan through the entire colour palette making it possible to stop the scan as soon as the desired colour is found This object is supposed to be combined with a hold and release push button so that pressing it the value 1 is sent starts the scan and releasing it the value 0 is sent stops it Figure 7 Colour scan The colour scan takes place according to the steps shown in Figure 7 however the starting point will not necessarily always be the same instead the closest point to the current colour will be adopted as the initial stage The complete cycle takes 15 seconds and it does not affect the current luminosity at all so no colour scan will take place if all the channels have been set to 096 Note the colour scan will be interrupted not only on the reception of the value 0 through the Color shift object but also on the arrival of any valid order through the following objects Scenes Sequences 1 byte Block 1 bit St
4. 9 Off Type sets the desired dimming type for the switch off of the LED module At once Smooth 1 and Smooth 2 2 On Action sets the action that will be executed on the LED module when LUMENTO X3 receives the value 1 through the Custom On Off X 1 bit object Analogously to the Off action mentioned above a luminosity or colour change is possible as well as state recovery switch on Last color so that whenever LUMENTO X3 receives a 0 through the corresponding Custom On Off object it saves into memory the value of the current colour of the LED module After that when the ON order arrives Custom On Off 1 LUMENTO X3 will set the LED module back to the previous colour Example Suppose that Custom On Off control number 2 is parameterised with Off Action Blue and On Action Last color and that at a certain time the active colour of the module is yellow A switch off order value O then arrives through the Custom On Off http www zennio com Technical Support http zennioenglish zendesk com 20 Zennio LUMENTO X3 RGB 2 object so the LEDs will turn blue Off Action prior to which LUMENTO X3 stores in memory the colour of the LED module that was active before the switch off yellow When a new switch on order value 1 is received the LEDs will light again in the colour stored before the switch off yellow 9 On Type sets the desired dimming type for the
5. Time sets the time length of the step i e the time LUMENTO X3 will wait before running the next step in seconds The steps or actions will be executed in order Thus when LUMENTO X3 receives the Scene number that triggers the sequence the first configured step will be executed http www zennio com Technical Support http zennioenglish zendesk com 29 Zennio LUMENTO X3 RGB Moreover if the sequence is cyclical once the last step finishes the sequence will be automatically executed again from the beginning An example of custom sequence configuration is shown in Figure 13 where the first three steps of Sequence 1 have been parameterised GENERAL Scene Sequence 1 FUNCTIONS Custom Orgi OrvOf 1 Scene Sequence Number 1 to 64 1 s Scenes Sequences f ene Sequence 1 Scene Sequence Type Custom Sequence Scene Sequence 2 f Scene Sequence 3 Cycic No Scene Sequence 4 Scene Sequence 5 Next Sequence No sequence v Scene Sequence 6 b E EE Scene Sequence 7 Luminosity Sending Send when sequence endi z Scene Sequence 8 gt Scene Sequence 3 Acton 1 Yes M Scene Sequence 10 Coke Predefined Color Predelined Colo RED Pr NM At Once Time x1 sec u a Acton 2 Yes Coke Predefined Colo Predefined Cole GREEN Dania ge EST Time x1 sec 15 Acton 3 Yes Coke RGBW Color R 255 z G 100 s B 65 a Dimming Type Equal to Action Time Time x
6. Zennio Passion for KNX innovation Se 3 1 o E lt SS 7 ce A e Ea LUMENTO X3 RGB PWM Dimmer for 4 Channel Constant Voltage LED DC Colour Modules ZN1DI RGBX3 Application program version 1 3 User manual edition 1 3 a m lt gt z lt 2 cc LLI un www zennio com Zennio LUMENTO X3 RGB Contents Document Updates tata tata 3 LINO UC Nr A A AA ti 4 TI NUMENEIOX3 aia 4 1 2 Installation E Q kkaiiEn 4 1 3 RGB LED DIOGd6Ss eet ere re en en en Me n Mee e eee nee e nea 7 2 Configuratio coit c oie estet oae euet descrive ve iS duet O E kn anand 8 3 ERS Parametrisatlon eie teet 10 3 1 Default Configuration ooooooooccnnncncnnonononnnonnnnnnnnnnnnnonnnnnnconnnnn ono nnnnnnnnnnnnno nr nnnnnnnnnnnnos 10 SA ee nanenane ananena enaa aa eana NIE IIR NI MEE 11 3 3 PUMNGUONS o2c2cec2ce ctor Beectcecdeecteecdeecteecdeecteecdeecdeedeecdeacdeacdeectesstesstunstenstecsten teste teetctats 16 3 3 1 Status Objects MEM T 17 3 3 2 Colour Selection ODjects ccccccccccccccsseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseeseesseseeeeeeeeess 18 3 3 3 Custom On Off SRM 19 3 3 4 Simple TIME iia 21 3 3 5 A 24 3 3 6 A oaee nas anne a eachs sagas sbeaazeacta sagas sbeaaseacha sagas a AEREE ESENE 25 3 3 7 je E ems 30 3 3 8 cUm T d 31 Annex I Communication Objects cccccnnocooocnnnnnccnnnononnnnnnnnconnnanononnnn
7. and moreover the same luminosity level 49 Max Light Level 96 defines the maximum effective brightness in percentage from 596 to 10096 that can be applied to the channels through a http www zennio com Technical Support http zennioenglish zendesk com 14 Zennio LUMENTO X3 RGB dimming order If this parameter is set to a value other than 100 a proportional reduction of the luminosity will apply However for coordination and update purposes LUMENTO X3 will always send to the KNX bus the theoretical luminosity value between 0 and 100 Example Let the value of this parameter be 70 In such case dimming orders for a luminosity of 10096 will actually set the luminosity to 7096 although the status object will in fact show the value 100 Analogously orders for a luminosity of 50 will actually set it to 35 although the status object will show 5096 2 Independent Channel Control RGB enabling this option brings up several communication objects that make it possible to switch on off each channel independently X On Off as well as to control their luminosity levels separately X Dimming and X Precise dimming If after sending a control order to an individual channel precise dimming step dimming dimming stop order etc an additional global dimming order precise or by steps is also sent the last colour proportion will be taken as the new base for the glob
8. communication objects which report the state of each channel independently and at any http www zennio com Technical Support http zennioenglish zendesk com 17 Zennio LUMENTO X3 RGB time These objects are X On Off Status and X Luminosity Status which behave analogously to the general status objects 3 3 2 COLOUR SELECTION OBJECTS Enabling this function brings up two new communication objects Direct color 1 byte and Color shift 1 bit 9 Direct Color it is a 1 byte communication object that permits directly selecting one of the 22 colours of the predefined palette It works similarly to Scene objects Every predefined colour is associated to a certain number from 1 to 22 as shown in Table 2 If one of these values decremented by 1 is written to the Direct color object the LED module will change to the corresponding colour immediately regardless of the dimming types At once Smooth 1 or Smooth 2 parameterised under the General screen Scene Value Colour R G B 1 0 OFF 0 o o0 gg 2 1 White 0 0 0 3 2 White Light 0 0 0 4 3 Blue 0 0 255 5 4 Blue Light 102 204 255 6 5 Blue Navy 0 0 102 7 6 Blue Cyan 0 255 255 8 7 Blue Turquoise 0 255 TT 9 8 Blue Lavender 128 128 255 10 9 Green 0 255 0 11 10 Green Light 128 255 51 12 11 Green Dark 0 102 0 13 12 Green Lime 128
9. possible to customise the state of the LED module after a bus voltage recovery and after a download from ETS lt lt GENERAL gt gt Start Up lt lt FUNCTIONS gt gt Start P Initial Status on BUS voltage recovery On z Initial Color BGB Color 7777 R 0 G D B 0 Status Sending No M Figure 14 Start up The following parameters can be configured 9 Initial Status on bus voltage recovery sets the initial status the LED module will adopt when the bus power failure situation ends or after a download from ETS http www zennio com Technical Support http zennioenglish zendesk com 31 Zennio LUMENTO X3 RGB Last the LED module will recover the same colour and brightness level it had before the bus power failure Note that this option does not apply after a download the LEDs will stay off gt Off the LEDs will always be initially off gt On the LEDs will always be initially on lighting in the colour defined through the Initial Color parameter which can be an RGB colour or a predefined colour see Table 2 9 Status Sending by enabling this parameter Yes the state of the LED module will be sent to the KNX bus on a power recovery or after a download thus updating other devices in the KNX system that may need it When enabled a new parameter is shown Delay This field sets the time in seconds that LUMENTO X3 waits until it transmits the status obj
10. shown making it possible to choose an At once Smooth 1 or Smooth 2 dimming for this action Luminosity The scene execution will in this case consist in changing the luminosity level without changing the active colour This option displays two new parameters Luminosity which sets the desired level from O to 255 and Dimming Type which sets the desired transition type At once Smooth 1 or Smooth 2 gt Predefined Sequence Three different pre set sequences are available Colorful Cool colors and Warm colors Scene Sequence Type Predefined Sequence M Predefined Sequence Colorful Time 1 min Warm colors Luminosity Sending Send continuously Y Every sequence consists of 5 steps smooth transitions between different colours of a particular time length They behave cyclically so when the last step of the sequence finishes it automatically starts over from the first step The default duration of every cycle is 1 minute being possible to modify it through the Time textbox the typed value must be in the range 1 255 minutes Note LUMENTO X3 will proportionally modify the action time of every step of the sequence according to the parameterised cycle time The Luminosity Sending field is intended to set when LUMENTO X3 will send the KNX bus the brightness status objects being the following options available http www zennio com Technical Support http zennioenglish zendesk co
11. 1 sec 10 Achon 4 No Acton 5 No Figure 13 Custom sequence 3 3 7 BLOCK This function permits locking the output of the device i e disabling the control of the LED module http www zennio com Technical Support http zennioenglish zendesk com 30 Zennio LUMENTO X3 RGB LUMENTO X3 will lock the output when it receives a 1 through the Block 1 bit communication object which is displayed after enabling this function From that moment any action being executed will be stopped and the LED module will maintain the colour and luminosity it had when the lock order arrived While locked any order received from the KNX bus will be ignored by the device i e the output will perform no actions LUMENTO X3 will unlock the output when the value O arrives through the Block object The LEDs will still maintain the colour they had before receiving the lock order No luminosity change commands received during the lock state will be taken into account by the output not even after the unlock event 3 3 8 START UP This function permits setting the desired state to be applied to the module when the device starts up A default or a custom configuration may be selected If the default configuration is chosen the LEDs will stay off after a download from ETS On the other hand after a bus voltage recovery the luminosity will be the same as before the bus power failure Under a custom configuration it is
12. 2 Programming Button 3 Programming Indicator 4 Test Button 5 Test Reverse Polarity Indicator 6 External Voltage Terminal 7 LED Control Terminal Figure 2 Connection scheme The device connects to the KNX bus via the incorporated terminal 1 which provides the device with bus power On the other hand an additional power supply 12 24 VDC depending on the specific LED module is needed for dimming the LEDs The external power supply is connected to the device through the corresponding screw terminal block included in the original packaging 6 The polarity of the external supply must be respected the positive pole of the external power supply corresponds to the positive pole of the terminal block and analogously for the negative pole If for whatever reason the connection of the power supply is carried out in the inverse way LUMENTO X3 will report this event through the Test Reverse Polarity Indicator 5 which will turn orange Also provided with the device is a second screw terminal block 7 where every LED module must be connected as well as the power line V The scheme of the terminal block is shown in Figure 2 Note the output terminal block can be wired before it is inserted into the device Note keep in mind that only LED loads can be connected to LUMENTO X3 Once the device is provided with bus power both the physical address and the application program can be downloaded even if no external p
13. Bit l C W DPT_Start 0 1 Start Stop Sequence 0 Stop 1 Start 29 1 Byte VO C RW DPT Scaling 0 100 Dimming Speed 1 0 Min Speed 100 Max Speed 30 1 Byte 1 0 C RW DPT_Scaling 0 100 Dimming Speed 2 0 Min Speed 100 Max Speed loc 31 1 Byte VO C RW DPT SceneControl 0 21 Direct Color Color number Scene 1 22 32 1 Bit O CTR DPT_Alarm 0 1 0 Error External Voltage 0 Normal 1 Low Ext Voltage 33 1 Bit O CTR DPT_Alarm 0 1 0 Error Overheating 0 Normal 1 Overheating 34 1 Bit l C W DPT_Start 0 1 Color Shift 0 Stop 1 Start 35 3 Bytes C W DPT_Colour_RGB 0 100 3 z 7 RGB Color 3 bytes RGB ctrl http www zennio com Technical Support http zennioenglish zendesk com 34 Join and send us your inquiries about Zennio devices http zennioenglish zendesk com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 Fax 34 925 337 310 www zennio com ee C info zennio com K NX Zennio Passion for KNX innovation RoHS
14. Dimming 0x0 Stop Ox1 Dec by 100 0x2 Dec by 50 0x3 Dec by 25 Dimming 4 bits dimmer ctrl http www zennio com Technical Support http zennioenglish zendesk com 33 Zennio LUMENTO X3 RGB Number Data type DPT Implemented range 1st boot P Reboot P Name Function 0X3 Dec by 12 0x5 Dec by 6 0x6 Dec by 3 0x7 Dec by 1 0x8 Stop 0x9 Inc by 10096 OXA Inc by 50 OxB Inc by 25 OxC Inc by 12 OxD Inc by 6 OxE Inc by 3 OxF Inc by 1 10 1 Byte l C W DPT_Scaling 0 100 Precise Dimming 1 byte dimmer ctrl 11 1 Bit l C W DPT_Switch 0 1 On Off 0 Off 1 On dic 14 1 Bit O CTR DPT_Switch 0 1 W y W v X On Off Status 0 Off 1 0n 15 17 1 Byte O CTR DPT_Scaling 0 100 W y W V X Luminosity Status 0 100 18 1 Bit O CTR DPT_Switch 0 1 W y W V On Off Status 0 Off 1 On 19 1 Byte O CTR DPT_Scaling 0 100 W y W Vv Luminosity Status 0 100 20 23 1 Bit l C W DPT_Switch 0 1 Custom On Off X 0 Off 1 On 24 1 Bit C W DPT_Switch 0 1 Simple Timer 0 Deactivate 1 Activate 25 1 Bit C W DPT_Start 0 1 Flashing 0 Deactivate 1 Activate W 0 63 run 26 1 Byte C W DPT SceneControl 128 191 save Scenes Sequences Scene Sequence value 27 1 Bit C W DPT_Enable 0 1 0 Block 0 Unblock 1 Block 28 1
15. Smooth 2 The times here refer to the complete transition from 0 to 10096 and the permitted values are from 3 to 65535 tenths of a second Both parameters are 10 i e 1 second by default The Smooth Dimming Times 1 and 2 can be decreased although not increased in runtime via the Dimming Speed 1 and Dimming Speed 2 communication objects respectively Please refer to Table 1 for the relationship between the most common speed values and their associated dimming times 7 Dimming Times ginning e eed T Sec ise time 0 25 AT 33 AT 50 RT 75 AT 10096 0 Table 1 Dimming speeds and times The minimum dimming time is actually 3 tenths of a second Example Let the parameterised time for the Smooth Dimming Time 1 be equal to 20 seconds At a given time during the execution the smooth dimming is required to be performed in half the time so this time becomes 10 seconds To achieve this the value 5096 should be sent to the Dimming Speed 1 object If the original time were to be reduced to the fourth part from 20 to 5 seconds it should be 75 the value to be sent to the mentioned object Sending the value 096 through Dimming Speed 1 will recover the original smooth dimming time 1 20 seconds Smooth dimming from to values other than 0 10096 on off is also performed at the same speed so the time required to carry it out will always be proportional to and lower th
16. al regulation Example Assume that the initial colour is 20 O 60 A precise dimming order is then sent to the blue channel B Precise Dimming 50 so the new base colour becomes 20 0 128 If a global dimming to the three channels is then sent for example Precise dimming 25 the resulting colour will be 10 0 64 9 Error Identification this option displays two 1 bit communication objects to report anomalous behaviours that may arise when LUMENTO X3 is working Error Overheating Object through which LUMENTO X3 notifies it is exposed to an excessive temperature higher than 90 C by sending the value 1 In that moment LUMENTO X3 will reduce the brightness level of the channels to 50 only if their current level is higher and the working frequency will be set to its minimum value 150 Hz When the temperature is again lower than 80 C LUMENTO X3 will send the value 0 through http www zennio com Technical Support http zennioenglish zendesk com 15 Zennio LUMENTO X3 RGB this object thus showing the end of this event and it will recover the brightness and frequency values it had before the error If 15 minutes after the beginning of the Overheating error the temperature is still not lower LUMENTO X3 will directly switch off its output for safety reasons Note take into account that even if the error identification has not been enabled by parameter the overheating protect
17. an that parameterised under Smooth Dimming Time http www zennio com Technical Support http zennioenglish zendesk com 12 Zennio LUMENTO X3 RGB Example Let the parameterised value for the Smooth dimming time 1 be 10 seconds 100 A global switch on order is then sent when the output is off so it will take 10 seconds to reach the maximum brightness level if the Dimming parameter has been configured as Smooth 1 However if the LEDs were already at a brightness percentage of 50 the time required to reach the full brightness 10096 will be 5 seconds one half of the 10 seconds parameterised Three more parameters are shown next grouped as Dimming Times 49 Precise Dimming this field can be used to define whether transitions commanded through both the general and the channel dependent Precise Dimming objects and also through the 3 byte RGB Color object in other words dimming orders performed by sending a certain luminosity value in percentage should be At once immediate Smooth 1 a progressive transition according to the defined Smooth Time 1 or Smooth 2 a progressive transition according to Smooth Time 2 49 Dimming defines whether step by step transitions i e through the 4 bit Dimming objects both the global object and those referring to each channel independently should be Smooth 1 a progressive transition will be performed according to the defined Smooth Time 1 or Smo
18. art stop sequence 1 bit and Direct color 1 byte 3 3 3 CUSTOM ON OFF Once enabled this function offers up to 4 additional ON OFF controls independently customisable GENERAL Custom On Off lt lt FUNCTIONS gt gt Custom On Off Onora No On Off 2 No y Or Qff 3 No On Off 4 No M Figure 8 Custom ON OFF http www zennio com Technical Support http zennioenglish zendesk com 19 Zennio LUMENTO X3 RGB The following parameters can be set for each of the custom ON OFF controls lt lt GENERAL gt gt On Off 1 lt lt FUNCTIONS gt gt Custom On Off y On Off 1 Off Action Luminosity Luminosity 0 Off Type At Once n Action Luminosity X Luminosity 255 On Type At Once Figure 9 Custom ON OFF configuration 9 Off Action sets the action to be run over the LED module when LUMENTO X3 receives the value 0 through the Custom ON OFF 1 bit object This can consist in a change in the luminosity Luminosity which will display a new parameter to set the desired value or a colour change being possible to select a specific colour from the predefined palette Predefined color which displays a drop down list with all the possible values see Table 2 or a manually defined colour RGB Color which will permit inserting numeric values from 0 to 255 for every colour component R G or B
19. e Scene Sequence 1 1 Fixed Color X Predefined Color OFF OOo oy At Once y Figure 12 Scenes Sequences For each of them the following configurable fields are available 49 Scene Sequence Number indicates the scene sequence identifying number from 1 to 64 whose reception decreased by 1 according to the KNX standard through the Scenes Sequences object will make the device apply the configuration to the LED module 9 Scene Sequence Type selects the desired action for each enabled scene sequence gt Fixed Color The scene will consist in setting the LED module to a specific colour when the Scenes Sequences object is received with the configured scene number Either a predefined colour see Table 2 or a custom colour by manually setting the RGB colour components can be selected If Fixed Color is selected besides running the scene it will be also possible to save it if the device receives a scene save order values http www zennio com Technical Support http zennioenglish zendesk com 26 Zennio LUMENTO X3 RGB 128 191 through the mentioned object the current luminosity levels of the LED module will be saved so when the same scene is executed again the colour acquired by the LEDs will be the one that was saved and not the originally parameterised in ETS Finally if Fixed Color is selected the Dimming type parameter will also be
20. ects To get an immediate transmission no delay this field should remain zero The start up state transmission is performed through the On Off Status and Luminosity Status communication objects and the analogous objects referred to the separate channels if enabled Note that the status objects need to stay enabled see section 3 3 1 Note bus power failures do not turn the LED module off unless the external power supply is also affected by the failure http www zennio com Technical Support http zennioenglish zendesk com 32 Zennio LUMENTO X3 RGB ANNEX I COMMUNICATION OBJECTS 0 2 Functional range shows the values that with independence of any other values permitted by the bus according to the object size may be of any use or have a particular meaning because of the specifications or restrictions from both the KNX standard or the application program itself 1st boot shows the cases where an object is assigned a certain value by the application program after a device download or a full reset In case the value of such assignment can be parameterised V is shown in column P Objects showing a hyphen are not assigned a particular value and therefore can be assumed to be initialised with the value 0 or with the corresponding updated value in case they depend on an external element sensors etc Moreover if the object is sent or is there an option to send it to the bus write or read re
21. ed 1 0 Min Speed 1435 RGB Color 3 bytes RGB ctrl 3 Byte T 30 Dimming Speed 2 0 Min Speed ER 35 RGB Color 3 bytes RGB ctrl Figure 4 LUMENTO X3 RGB Default topology The following communication objects appear 49 Dimming a 4 bit object destined to step dimming the general brightness luminosity level Steps upwards or downwards of 1 2 3 6 12 25 50 and 100 are possible Precise Dimming a 1 byte object destined to perform a precise dimming over the general brightness level by setting a concrete percentage value 9 On Off a 1 bit object destined to perform a general switch on or switch off of the LED strip A switch on order through this object will recover in any case the colour that was active prior to the switch off with either the maximum luminosity 10096 or with the luminosity level it had before the switch off depending on the On Light Level parameter see section 3 2 9 Dimming Speed 1 a 1 byte object that allows modifying in runtime the speed of the Smooth 1 dimming see section 3 2 http www zennio com Technical Support http zennioenglish zendesk com 10 Zennio LUMENTO X3 RGB 49 Dimming Speed 2 similar to Dimming Speed 1 but referred to the Smooth 2 dimming RGB Color 3 byte object that permits selecting a particular colour by precisely specifying the luminosity level of each output channel R G and B Therefore each of the three bytes i
22. g O order is received Either a predefined colour see Table 2 or a custom colour by manually defining each of the RGB colour components can be selected 3 3 6 SCENES SEQUENCES This function allows defining different scenes which consist in a specific light ambient or a dimming sequence so they can be triggered when the corresponding value is http www zennio com Technical Support http zennioenglish zendesk com 25 Zennio LUMENTO X3 RGB received from the bus through the Scenes Sequences 1 byte object The Start Stop Sequence 1 bit object will be displayed to allow re executing the last sequence played by writing the value 1 or stopping the current sequence in execution 0 Note the Start Stop Sequence object only applies to dimming sequences and has no effect over static scenes Moreover after a download from ETS partial or complete if the value 1 is sent through this object the triggered sequence will be the first one that was parameterised unless it is of the Fixed Color type in such case the first one different from this type will be executed LUMENTO X3 RGB allows configuring up to ten scenes sequences which can be individually enabled from Scenes Sequences in ETS lt lt GENERAL gt gt lt lt FUNCTIONS gt gt Scenes Sequences Scene Sequence 1 Scene Sequence Number 1 to 64 Scene Sequence Type Color Predefined Color Dimming Typ
23. he following parameters Cyclic Yes will define a cyclic sequence after the last parameterised step the sequence will start over while No will define a non cyclic sequence in such case there is also the possibility of triggering after the last step of the sequence another parameterised sequence Luminosity Sending this parameter can be set to Send continuously during the light dimming the brightness level will be sent to the KNX bus through the Luminosity Status object as well those corresponding to the individual channels if enabled only if the option to send statuses has been activated from the Functions screen or to Send when sequence ends the brightness level of the output will be sent to the bus once the last step of the sequence finishes no matter if the option to send the status objects during the dimming is enabled or not from the General screen However in both cases the status objects need to be enabled by parameter see section 3 3 1 Note that the minimum time parameterised for sending the status objects will apply For every step the following parameters can be configured Color sets the desired colour for the LED module either RGB or predefined Dimming Type At once Smooth 1 Smooth 2 or Equal to action time If the latter is selected the dimming will be carried out gradually switching from the current level to the new one by taking the time defined for the Time field
24. hite Red while the LED channels turn on successively 1 2 3 4 1 depending on the channel enabled with every press If the LED modules are properly connected to the device the colour that will turn on with every press red green or blue will be the same as in the Test indicator meaning that no channel was interchanged during the connection process To leave the Test Mode just push the Test button at least for 3 seconds until the associated indicator and the LED module switch off Note while the Test Mode is active any order received from the KNX bus will be ignored until the deactivation of the mode To obtain detailed information about the technical features of LUMENTO X3 as well as on security and on the installation process please refer to the Datasheet included in the original packaging of the device and also available at http www zennio com http www zennio com Technical Support http zennioenglish zendesk com 6 Zennio LUMENTO X3 RGB 1 3 RGB LED DIODES The LUMENTO X3 RGB application is able to dim the colour and the luminosity of a RGB LED i e featuring R G and B components module In reality both the colour and the luminosity are controlled by adjusting the level of the light emitted by the component colours i e a change in the global luminosity is actually a joint adjustment of the luminosity of the component colours however luminosity changes are performed by maintaining the proportion be
25. ion is always enabled although in that case the bus will not be notified gt Error External Voltage Object through which LUMENTO X3 notifies that the received external power is incorrect due to any of these events too low voltage total absence of power source disconnected or inversion in the polarity of the power supply this is also visually notified by the Test indicator which turns on in orange When LUMENTO X3 detects any of these anomalous situations it sends the value 1 through this object When the event finishes it sends a O 3 3 FUNCTIONS LUMENTO X3 RGB offers a set of different functions see Figure 6 which may be selectively enabled depending on the requirements of the KNX system GENERAL lt lt FUNCTIONS gt gt lt lt FUNCTIONS gt gt Status Object No NEM Color Selection Objects No X Custom On Off No v Simple Timer No Flashing No v Scenes Sequences No 7 Block No Start Up Default Figure 6 Functions The available functions are detailed next http www zennio com Technical Support http zennioenglish zendesk com 16 Zennio LUMENTO X3 RGB 3 3 1 STATUS OBJECTS This function allows enabling a 1 bit status object On Off Status and a 1 byte status object Luminosity Status responsible for reporting the general state of the output at any time thus updating other devices in the KNX system if re
26. ity level of an RGB diode module Moreover it permits configuring a set of additional functionalities which makes LUMENTO X3 a very versatile device 9 Wide range of alternatives for the LED module colour control both for a general control and for a per channel R G B control gt 1 bit objects for a general and per channel switch on switch off gt 4 bit objects for general and per channel step dimming gt 1 byte objects for general and per channel precise dimming in percentage gt 3 byte object for an RGB precise dimming in percentage gt 1 byte scene friendly object with a number of pre set colours gt 1 bit object for colour scanning and selection 49 General dimming features such as Smooth dimming times for progressive colour transitions gt Different dimming modes At once Smooth 1 or Smooth 2 for each case Restriction of the maximum allowed light level 9 Custom ON OFF possibility of enabling up to four different ON OFF controls with a specific colour luminosity and dimming type for each case 2 Simple Timer and Flashing timed ON OFF sequences of the LED module 9 Scenes Sequences possibility of enabling up to ten different scenes sequences which can consist in a single luminosity change or a custom sequence 5 customisable steps e Block option to lock unlock the control over the LED module http www zennio com Technical Support http zennioenglish zendesk com 8
27. m 21 Zennio LUMENTO X3 RGB Send Continuously the brightness level will be continuously sent through the Luminosity Status object only if the Send Luminosity when LEDs are dimming parameter has been enabled from the Functions screen restricted to the parameterized minimum time for values sent consecutively Don t Send No matter if the status sending option is enabled or not under the Functions tab no status object will be sent to the KNX bus during the execution of the sequence The next three tables show the predefined colour patterns and the action times of the three sequences Sequence 1 Colorful Step Colour RGB Action time 1 Red 255 0 0 t 5 2 Green 0 255 0 t 5 3 Blue 0 0 255 t 5 4 Magenta 255 0 255 t 5 5 Yellow 255 255 0 t 5 Sequence 2 Cool colors Step Colour RGB Action time 1 Blue 1 100 128 255 t 5 2 Green 1 20 255 100 t 5 3 Green 0 255 0 t 5 4 Green 2 0 255 77 t 5 5 Blue 0 0 255 t 5 Sequence 3 Warm colors Step Colour RGB Action time 1 Red 255 0 0 0 t 5 2 Magenta 255 0 255 0 t 5 3 Pink 255 80 128 0 t 5 4 Orange 255 51 0 0 t 5 5 Yellow 255 255 0 0 t 5 http www zennio com Technical Support http zennioenglish zendesk com 28 Zennio LUMENTO X3 RGB Custom Sequence Selecting this option will make it possible to customise sequences of up to 5 steps actions by setting t
28. nnioenglish zendesk com 21 Zennio LUMENTO X3 RGB 9 On Duration this parameter sets the time the LED module will stay on before switching off again A O in this field means endless i e no timing is applied to the switch on In other words the behaviour of the simple timer is as follows When LUMENTO X3 receives a 1 through the Simple Timer communication object an ON order is sent to the output applying the On Delay if parameterised The output stays on depending on the On Duration and then turns off unless this duration has been parameterised with 0 gt When LUMENTO X3 receives a 0 through the Simple Timer communication object the output is switched off with the corresponding Off Delay if parameterised 9 Multiply allows progressively increasing multiplying in runtime the On Duration time or the On Off delays of the output Two situations are distinguished gt No Multiply e If the On delay count is already running it will be reset every time a new 1 is received through the Simple Timer object e lf the output has already been activated and the On Duration time is counting it will be reset whenever a new 1 is received e If the Off delay count is already running it will be reset every time a new 0 is received gt Multiply e fthe On delay count is already running and the value 1 is received several times through the Simple Timer objec
29. nnnnnnnnnnnrnnnnnnnnnnnnnnnnnnnnnnnos 33 http www zennio com Technical Support http zennioenglish zendesk com 2 Zennio LUMENTO X3 RGB DOCUMENT UPDATES Version Changes Changes in application program Unconditional transmission of the ON OFF status object after a switch on or switch off order through any of the objects that permit it even if it did not imply an actual switch of the previous state and with independence of the parameterised minimum time between transmissions which is only considered for the Luminosity level status object Change in the smooth dimming algorithm on the reception of successive orders increments are applied to the final luminosity of the previous order no matter if the dimming process was interrupted Changes in application program New general ON OFF control object with memory Improvement of the Custom On Off controls new option to change only the luminosity without affecting the colour Improvement of the Scenes function according to the above approach 1 bit object hold amp release for colour scanning Independence between the 3 general controls 1 byte 4 bits 1 bit and their dimming speeds immediate smooth 1 smooth 2 New 3 byte control RGB Color Page s http www zennio com Technical Support http zennioenglish zendesk com 3 Zennio LUMENTO X3 RGB 1 INTRODUCTION 1 1 LUMENTO X3 LUMENTO X3 is the LED dimming s
30. o the switch off although the luminosity itself will turn maximum or not depending on the option selected for this parameter Apart from the exception of the first switch on which will imply white colour and full luminosity in the particular case of performing the switch on after having set accidentally or not all three channels to zero through their respective dimming or precise dimming objects the colour acquired on the switch on will as well be white and the luminosity maximum The following example illustrates this Example The following sequence shows a set of actions and their effects Assume that the On Light Level has been parameterised as Previous Action Effect 1 Download a 2 Global switch on order White 100 brightness 3 Direct Color 12 Green 100 brightness 4 R Precise dimming 5 Red level 5 5 G Precise dimming 5 Green level 596 6 B Precise dimming 5 Blue level 5 7 R Precise dimming 0 Red level 0 8 G Precise dimming 0 Green level 0 9 B Precise dimming 0 Blue level 0 10 Global switch off order 11 Global switch on order White 10096 brightness Refer to section 3 3 2 for the Direct Color object If a complete switch off had not occurred as a consequence of individually setting all three channels to zero the global switch on would have recovered because of the parameterisation the previous colour
31. olution from Zennio for single colour LED DC diode modules or combined LED DC diode modules of up to three colours Red Green and Blue It offers three independent output channels for modules powered with 12 24 VDC up to 2 5 A each The device may be programmed with three different application programs depending on the type of the LED modules to be controlled 9 LUMENTO X3 LED independent control over up to three single colour LED modules e each channel connected to the output corresponds to an independent single colour module which will generally be installed and operated independently of the other modules 9 LUMENTO X3 RGB joint control over one three colour RGB LED module i e each channel connected to the output corresponds to one colour component R G or B of the same module being all of them typically controlled jointly ds E TEST gt i Zennio Push 3sec 20 LED USE ema lone UMENTO X3 E LED DIMMING ZN1DI RGBX3 COMOut COM C 12 24v R 0 q Je cE 2 TA la ae IE leo ES KNX 2 5A Channel Null Figure 1 LED Dimmer 1 2 INSTALLATION Figure 2 shows the connection scheme of LUMENTO X3 http www zennio com Technical Support http zennioenglish zendesk com 4 Zennio LUMENTO X3 RGB LED module terminal C LED module power V 1 Red Channel R 2 Green Channel G 3 Blue Channel B 4 Not in use 1 KNX Connector
32. order to start the flashing sequence Flashing 1 it will be reset no matter what the current stage of the sequence is GENERAL Flashing lt lt FUNCTIONS gt gt Flashing On Duration 40 1 sec 20 Off Duration x0 1 sec 20 Number of Repetitions 0 Endless 0 On Color Predefined Color z Predefined Color WHITE uE Final Color Predefined Color X Predefined Color OFF 7 Figure 11 Flashing These are the parameters that can be configured for the flashing function 9 On Duration sets the length of ON stages of the flashing sequence i e the time the channels will remain on before turning off again 9 Off Duration sets the length of OFF stages of the flashing sequence i e the time the channels will remain off before turning on again 499 Number of Repetitions defines the number of times the ON OFF sequence will be repeated when the flashing function is triggered For an unlimited number of repeats the value 0 should be typed here the sequence will be repeated until the reception of an order to deactivate the flashing 9 On Color sets the colour to be adopted by the LEDs during the on stages Either a predefined colour see Table 2 or a custom colour by manually defining each of the RGB colour components can be selected 9 Final Color sets the colour to be adopted by the LEDs once the last flashing sequence ends as well as when the Flashin
33. oth 2 progressive transition according to the defined Smooth Time 2 9 On Off permits defining the transition type At once Smooth 1 or Smooth 2 that will apply to the switch on or switch off orders Note smooth dimming is intended to let the user appreciate a progressive change in the luminosity level with the option to interrupt it once the desired level is reached Therefore this function is typically linked to a pushbutton that once released by the user stops the smooth dimming that began when it was pressed Because of this it is advisable to parameterise a dimming step of 10096 so a sole long press instead of successive long presses is enough to step through all the available light levels and to stop at the most comfortable one Finally apart from the desired dimming times the following parameters are shown http www zennio com Technical Support http zennioenglish zendesk com 13 Zennio LUMENTO X3 RGB 9 On Light Level sets the desired level of luminosity for the switch on orders received through the global On Off object In other words it permits setting whether the LEDs will acquire the maximum brightness level 100 or the one they had prior to the switch off Previous whenever a switch on order arrives On the very first switch on the luminosity will be set at 10096 and the colour will be white Note on a global switch on the LED module recovers the colour it had prior t
34. ower is being provided http www zennio com Technical Support http zennioenglish zendesk com 5 Zennio LUMENTO X3 RGB After the first connection to the KNX bus or after a download the programming indicator 3 will typically start blinking in blue while the Test Reverse polarity indicator 5 remains in constant blue for about 25 seconds Before performing any action over the device it is important to wait until both indicators turn off again i e they are not lighting in blue anymore since LUMENTO X3 is carrying out an internal update Note if the device is found to be only connected to the KNX bus and the external power is not being supplied this internal update will be postponed until it is The functionality of the main elements of the device is described below 49 Programming button a short press on this button sets the device into the programming mode while the associated indicator turns red If this button is held while plugging the device into the KNX bus LUMENTO X3 goes into the secure mode The indicator blinks in red 49 Test button a long press on this button of at least 3 seconds until the associated indicator lights in white activates the Test Mode of the device which allows verifying the correct connection of the LED modules This test is carried out as follows once the Test Mode is activated every time the button is short pressed the associated indicator colour will change Red Green Blue W
35. quests after a download or a device reset from ETS the marks W or R will be shown respectively for transmissions or read requests Reboot shows the cases where an object is assigned a certain value by the application program after a bus power failure In case the value of such assignment can be parameterised v is shown in column P Objects showing a hyphen are not assigned a particular value and therefore can be assumed to maintain their previous value after the failure or with the corresponding updated value in case they depend on external elements sensors etc Moreover if the object is sent or is there an option to send it to the bus write or read requests after a bus failure the marks W or R will be shown respectively for transmissions or read requests 1 bit vo Flags C W Data type DPT DPT_Switch Implemented range 0 1 1st boot P Reboot P X On Off 0 Off 1 On Function 4 bits C W DPT_Control_Dimming 0x0 Stop Ox1 Dec by 100 0x2 Dec by 5096 0x3 Dec by 25 0X3 Dec by 1296 0x5 Dec by 6 0x6 Dec by 3 0x7 Dec by 1 0x8 Stop 0x9 Inc by 10096 OxA Inc by 5096 0xB Inc by 2596 OxC Inc by 1296 OxD Inc by 6 OxE Inc by 396 OxF Inc by 196 X Dimming 4 bits dimmer ctrl 1 bit C W DPT_Scaling 0 100 X Precise Dimming 1 byte dimmer ctrl 4 bits C W DPT_Control_
36. quired Status bject Yes Y Send On Off 1 when Luminosity is not equal to 0 xj Send Luminosity when LEDs are dimming Yes Y Min time between status 1 sending x 1 sec Independent Status Objects No X 49 Send On Offz1 when sets when the value 1 on is sent through the On Off Status object to the bus being the following options possible gt Luminosity is not equal to 0 when the brightness level gets to a value different from 0 the object On Off status will be send the value 1 The value 0 will be only sent when the luminosity reaches 0 gt Luminosity is equal to 100 the On Off Status object will only send the value 1 when the brightness level gets equal to 10096 The value O will be only sent when the luminosity reaches 0 The ON OFF status object is sent in any case after the reception of an ON OFF order through the analogous control object 49 Send Luminosity when the LEDs are Dimming this option allows selecting whether to send the brightness status of the output through the Luminosity Status object or not default option If enabled the following field will be also shown Minimum Time Between Status Sending sets the minimum time in seconds between consecutive brightness values sent to the bus through the Luminosity Status object This restriction applies to smooth dimming 9 Independent Status Objects activates eight additional
37. s related to one specific channel When entering the parameter edition of LUMENTO X3 RGB for the first time the following window will be shown GENERAL lt lt GENERAL gt gt lt lt FUNCTIONS gt gt PWM Frequency 488 Hz X Smooth Dimming Smooth Dimming Time 1 10 0 to 100 in x0 1 sec Smooth Dimming Time 2 10 T 0 to 100 in 0 1 sec Dimming times Precise Dimming At Once X Dimming Smooth 1 On Off At Once X On Light Level Previous v Max Light Level 100 Independent channel control No Error Identification No X Figure 5 Parameterisation screen by default As seen in Figure 5 the parameterisation window is divided into two main tabs which will be explained in detail in the next sections 9 General permits parameterising global features of the device 9 Functions permits enabling and configuring specific functions of the device 3 2 GENERAL WINDOW This section of the parameter edition allows setting several global features of LUMENTO X3 RGB 9 PWM frequency the working frequency of the LED regulator The available values are 150 300 488 and 600 Hz The default frequency is 488 Hz http www zennio com Technical Support http zennioenglish zendesk com 11 Zennio LUMENTO X3 RGB 9 Smooth Dimming the time LUMENTO X3 takes to perform soft luminosity transitions Two different smooth transition modes are available Smooth 1 and
38. switch on of the LED strip At once Smooth 1 or Smooth 2 3 3 4 SIMPLE TIMER This function allows performing a switch on of the LED module connected to LUMENTO X3 and a later automatic timed switch off being also possible to insert delays The time length the luminosity level and the switch on type can also be parameterised This function may be useful when a switch on of a certain duration i e the LEDs will be automatically switched off afterwards is required for example upon movement detection lt lt GENERAL gt gt Simple Timer lt lt FUNCTIONS gt gt Simple Timer On Delay x0 1 sec 0 No delay 50 7 Off Delay 0 1 sec 0 No delay 0 On Duration x0 1 sec 0 Endless 50 Multiply Ves On Color Predefined Color Predefined Color WHITE X On Type Smooth 1 Figure 10 Simple timer 9 On Delay this parameter sets the time LUMENTO X3 will wait since the reception of the Timer ON order Simple Timer 1 and the actual switch on of the LED module This value must be set in tenths of a second e g for a delay of 2 5 seconds typing 25 is required If no delay is needed this field must remain zero 9 Off Delay this parameter sets the time to be waited between the reception of the Timer OFF order Simple Timer 0 and the actual switch off of the LED module Works similarly to the On Delay http www zennio com Technical Support http ze
39. t then the actual delay time will be n times the parameterised time being n the number of times the value 1 is received e If the output has already been activated and while the On Duration time is counting the value 1 is received several times then the actual http www zennio com Technical Support http zennioenglish zendesk com 22 Zennio LUMENTO X3 RGB duration will be n times the parameterised time being n the number of times the value 1 is received e If the Off delay count is already running and the value 0 is received several times then the actual delay time will be n times the parameterised time being n the number of times the value 0 is received Note the multiply option may result particularly useful under parameterisations with no ON and OFF delays Nevertheless as already explained and as the following example shows these delay times if parameterised with a value other than 0 do also admit multiplication Example Let the following be parameterised On Delay 3 seconds Off Delay 3 seconds On Duration 5 seconds The graphs bellow reflect some possible situations if the values 0 or 1 are received from the which is represented as 0 and 41 respectively for the cases of having the multiply option enabled and disabled With no multiplication http www zennio com Technical Support http zennioenglish zendesk com
40. tween the components so in practice it is not the colour itself but the light intensity what is perceived to be changing RGB LED diodes are made of three different colours Red Green and Blue The result of mixing the three first colours in the same proportion is as well the White colour as shown in Figure 3 Other intermediate colours are obtained by combining the three main colours R G B in different proportions Figure 3 Combination of the Red Green and Blue colour components As already stated luminosity or brightness refers to the amount of light that the LED strip is emitting at a given time The value of the general or overall brightness of the set of diodes has been defined as the brightness of the component that emits with the highest intensity On the other hand the regulation of the general brightness is carried out so that the human eye perceives the visible colour as constant by increasing or decreasing the brightness of the three colour components together without losing their proportions Note the colour that is visually perceived the colour actually obtained may vary from the theoretical colour depending on the LED module and the colour diffuser being used http www zennio com Technical Support http zennioenglish zendesk com 7 Zennio LUMENTO X3 RGB 2 CONFIGURATION The LUMENTO X3 RGB application allows as stated in the previous section controlling the colour and the luminos

Download Pdf Manuals

image

Related Search

Related Contents

V-Tunnel Quick Installation Guide  要求水準書1 - 公立小野町地方綜合病院ホームページ  Sony PS-LX250H Turntable User Manual  Whirlpool ET1 8MK User's Manual  TRENDnet 108Mbps User's Manual  Indian Standards on DVDs Installation Manual Version 1.0  User`s Manual of ISaGRAF Embedded Controllers  USER`S MANUAL. .    Viewsonic Graphic Series 19" DIGITALMEDIA VG920  