        USER MANUAL
         Contents
1.      BERIL    vai    BERIL VIP       15    IPX3  protected against spatter                                                        Model Rated Rated Weight Dimensions   Heated area   voltage power kg mm m3  V kW   BERIL 2 5 220 2 5 1 5 70x230 62 5  BERIL 3 220 3 1 0 70x230 75  BERIL 4 220 4 1 5 70  230 100  BERIL 5 220 5 1 0 70x230 125  BERIL 6 380 6 6 5 130x440 150  BERIL 9 380 9 6 5 130x440 225  BERIL12 380 12 6 5 130x440 300  BERIL 15 380 15 6 5 130x440 375  BERIL 25 380 25 6 5 130x440 625   2  PACKAGE   1  Boiler    Beril      2  Boiler manual   3  Boiler packaging   4  CP    Beril    control unit or    BERIL    control module   5  Control unit or module packaging   6  CP    Beril    manual   3  SAFETY REQUIREMENTS    When installing the boiler heating system  it must be grounded   Boiler conducting parts  clamps  must be protected   Electrical power protection against power overloads and short circuiting are made with an  automatic switch to a power interruption  depending on the boiler capacity   Must be strictly followed  PHASE ZERO GROUND     Heating system threaded or welded joints must ensure airtight     Not allowed water on the external surfaces of the boiler     To the boiler service is admitted to persons who are older than 18 years old  who know the boiler    design and the provisions of the boiler                  It is prohibited to use boiler without an expansion tank  and when in the heating system is  frozen water    The manufacturer boiler duration is 10 y
2.  drinking water     When using heating liquid    Beril    or    Beril V I P     in heating system  it is useful to pour out  heating liquid from system to prevent system silting  filter it  trough the multi layer gauze or  filter paper   rinse the heating system and fill it up with the filtered heating liquid     To increase boiler and whole heating system lifetime  as wall as to increase its efficiency  we  recommend to combine system rinse with boiler prophylaxis  cleaning boiler heaters to metal  shine  removing installed electric unit    If the heating liquid evaporates from your systems expansion tank  just add appropriate amount  of boiled water  In time the intensity of special additives decreases  because of the continuous  entering of oxygen in system from surrounding environment  It is recommended to change  heating liquid in every 3 years    All heating system maintenance repairs must be executed with boiler shut down               9  Boiler doesn   t switch  on  automatic protection  is triggered    2  Heating system doesn   t  warm up  warms up  poorly     3  Room where the heating  system is mounted  doesn   t warm up  enough    4  Boiler uses rated power    but heating is going only to   closest boiler pipe     5  Boiler is losing power    1  Short circuiting in  Electricity Grid caused  by wrong connection   2  Check flow trough the  boiler     3  Temperature of heating    is set too low  Boiler  and radiator connection  schemes don   t  compliance with  schem
3. USER MANUAL    Ionic boiler heating system               SIA    BERIL     Ieri  u iela 48  Riga  LV 1084  Latvija   Tel    37167501262  Mob tel    37126605309    Ltd     BERIL     Ieriku street 48  Riga  LV 1084  Latvia   Ph    37167501262  Mob ph    37126605309           befil  Dear Costumer     Thank you for purchasing our production  Carefully read the instructions contained in this  instruction booklet  Before instalation  carefully read throught all terms and regulations of  instalation  This Instruction contains information  wich must be known and used in  expluatation period of this product     1  After boiler installation  inform the user regarding its operation and give him this  manual  which is an integral and essential part of the product and must be kept with care for  future reference    2  Installation and maintenance must be carried out by professionally qualified personnel   according to current regulations and the manufacturer s instructions  Do not carry out any  operation on the sealed control parts   3  Incorrect installation or inadequate maintenance can result in damage or injury  The  Manufacturer declines any liability for damage due to errors in installation and use or failure  to follow the instructions    4  Before carrying out any cleaning or maintenance operation  disconnect the unit from the  power supply using the system switch and or the special cut off devices    5  In case of a fault and or poor operation  deactivate the unit and do not atte
4. anual    BOILER ELECTRICAL CONNECTION   Boiler electrical connection must be executed by persons  who have permission to work with  electric systems with 100 W  in order that is strictly defined    Heating system must be grounded    Grounding resistance must not be less than 0 1 Om    All electric works must be executed using multicore  copper wire with crosscut adequate to  power loads    Wires  used for connection must be carefully cleaned  also from oxide layer    Power wires must be connected using connectors  which has anti corrosion coating  and are  cleaned from stratification    a  Connection with control unit CP       Picture 1  Electrical connections for boiler    Beril             In1 GND In2 GI                                        Picture 2  3 phase boiler    Beril    electrical connection with control panel ERTC 3 33      In1 GND In2                                   Picture 3  1 phase boiler    Beril    electrical connection with control panel ERTC 3 33                   Motual connections with heating system  heated floors  radiators and water heaters                                               1  Boiler  Beril   7  Circulation pump   2  Control panel  Beril   8  Three way valve    3  Heated floors  9  Connections of sensors   4  Radiators  10  Mounting element    5  Inside temperature controller                            Boiler    Beril         Control panel  Beril       Circulation pump      Hydrophores      Safety group    6  Armature    7  Filling valv
5. e    8  Safety group    9  Heated floors    10  Three way valve    11  Radiators    12  Combined water heater   13  Inside temperature controller   14  Connections of sensors   15  Mounting element         amp                                                                         5  IT IS FORBIDDEN TO USE BOILER       without grounding and zero wiring     without automatic switch  protection device      in explosive and flammable areas     in rooms with particular moisture  condensation  on the ceiling and walls      inrooms with current conductive dust     inrooms with chemically active environment     fully or partly locked isolating valves at boiler input or output without using  safety group  protection valve  manometer  automatic air output device  heating  systems with membrane expansion tank    6  HEATING LIQUID MANUAL    In heating system for boiler    Beril    must be used only specially for this boiler made heating  liquid    Beril    based on ethylene glycol or    Beril V I P     based on Propylene glycol   Using regular water in heating system  even if complies with requirements of the standard EN  26461 1  drinking water   can cause unintended consequences     water freezing in heating system if the air temperature is negative  this could cause  heating system damage    corrosion of heating system constructing elements    Internal heat transfer surface organic antifouling  which negatively affects whole heating  system technical status and working capacity   Hea
6. ears from the date of connection of the boiler  if the  consumer complies with those requirements and recommendations that are set out in this manual   All responsibility for any consequences that may occur when operating the boiler after the  specified expiry of boiler  switches to the consumer    The consumer may agree with the producer  seller  boiler usage extension     4  INSTALLING AND PREPARING    Warning  Secure boiler functioning depends on proper installation and connection   Installation and connection of the consumer must be reconciled in the following instances     Electrical energy supply company whose electric networks are used for  connecting the boiler     Local electric power monitoring instance     HEATING SYSTEM   Installing a heating system must comply with the purity of the pipeline to remove metal shavings  and other foreign matter from entering the pipelines  When installing the system the coarse  treatment filter is installed  After installation  the system must be thoroughly rinsed  it is  advisable to use inhibitors  Beril         Set the boiler  In the heating system the boiler is set vertically  Protection cap must be placed at  the bottom     Using this system with cast iron radiators is not recommended     Heating systems implementation and installation  as well as the boiler installation in the system   start and adjustment should be executed by specialized organizations with appropriate licenses   as well must be fulfilled ticket attached to m
7. es shown in this  manual  There is air in  heating system  caused  by wrong connection   Inadequacy of the boiler  power and the power of  heating system  pipes   radiators  convectors    3  All heating system  installation power must be  15     20   higher than  building heat losses   4  Disturbed heating liquid  circulation in heating  system     5  Inside of boiler may be  dirt  rust etc        7  POSSIBLE DEFECTS AND PREVENTING METHODS     1  Call electrician to check  connected system  compliance with    CP  setting and operating  manual    and this    User  manual       2  Increase temperature     Adjust connection schemes  according to schemes that  are shown in this manual   Prevent mounting mistakes   add heating liquid using  leak valve under pressure     Adjust boiler power to  heating installation power     3  Test building heat  balance accuracy    4  Clean and carefully rinse  heating system   recommended to use for this  purpose inhibitor    Beril      Use ragged filter  cleaning it  periodically     5  Clean boiler heaters to  metal shine  removing  installed electric unit               8  WARRANTY       1  Boiler service warranty period applies to all the working time   2  Warranty does not work  reclamation for boiler work will not be accepted  free repair or  change will not be done  in following cases      Electricity grid doesn   t comply required     one of the boiler heating element seals is damaged      heating system realization and installation  and 
8. its connection to system wasn   t done by  specialized organization without according licenses      Violated requirements and recommendations mentioned in this manual  3  If customer wishes  the heating system with boiler    Beril    is installed and further system  service is done by licensed expert     1  STORAGE AND TRANSPORTATION TERMS  Boiler must be stored in closed space with natural ventilation  where temperature and humidity is  significantly lower than in the open air in temperate and cold climate regions  with temperatures    from  40    C to  50 C at a relative humidity of not more than 80  at temperature  25 C     Equipment can be transported by any closed transport  according to measures for bursting loads     Sales statement   Electrical ionic boiler    Beril    is in conformity with 73 23 EEC and 93 68 EEC    Seller s stamp   Sold     Sales date     befil                  SIA                 Latvija  Ieri  u iela 48 Riga  LV 1084   tel    37167501262   mob tel    37126605309    Ltd     BERIL     Ieriku street 48  Riga  LV 1084  Latvia  ph    37167501262  Mob ph    37126605309    
9. mpt to repair it or  directly intervene  Contact professionally qualified personnel  Repair replacement of the  products must only be carried out by professionally qualified using original spare parts   Failure to comply with the above could affect the safety of the unit    6  This unit must only be used for its intended purpose  Any other use is considered improper  and therefore dangerous    7  The images given in this manual are a simplified representation of the product  In this  representation there may be slight and insignificant differences with respect to the product  supplied    8  Information included it this booklet  has been thoroughly checked  but we do not  have any liability for any cartographical errors  technical or editors interpretation  shown in images or translations of originals                   Ionic boiler    Beril     further     boiler  is made for water heating for inhabited and uninhabited area    closed autonomous heating systems  with conditions that these areas has insulation and    ventilation  has no atmospheric precipitation or moisture condensation   outdoor air temperature    is  40   C to  40   C  relative air humidity 98  at  25   C     1     TECHNICAL SPECIFICATION    Rated power frequency  Hz    Max outgoing temperature from boiler  C    Usable heating liquid   Heating liquid capacity of the boiler consumed power  kW  1     Current    Execution of the anti humidity protection degree    Main dimensions and characteristics    50   1  80 
10. ting liquid    Beril    or    Beril V I P     Other heating liquids and antifreeze usage in heating  systems with boiler  Beril  can lead to emergency situation  because of their inadequacy   electric resistance  for boiler technical parameters   Company provides heating liquids    Beril    and  Beril V I P    whose crystal formation   freezing  temperature is   30   C  This temperature doesn t change using boiler for many years   only if heating liquid concentration says the same                           From the graph you can see that between crystal formation point and freezing point there are  considerable temperature gap  in were there are both phase conditions     liquid and ice crystals      and there are no    burst    effect        Thanks to this quality  the heating system is not subjected to damage in the time of un freezing   as it would be using water  Company made heating liquid final freezing temperature is   45   C   heating liquids    Beril    and    Beril V I P     has added special additives  which slows corrosion  of metals  prevents compactor damage  rubber  Teflon  and scale formation on heater     Heating liquid    Beril V I P     are made on base of Propylene glycol used in grocery products   like shampoo  medicinal products  cosmetics  animal food and non alcoholic drinks  Thanks to  its environmental cleanliness heating liquid    Beril V I P     can be used in dual contour heating  systems  without fear from result  if the heating liquid gets in the
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  CDA SV 980 User's Manual    Samsung AM26B1C13 User's Manual  pd41302876734JokerT User Manual  Mesures conductimétriques : étalonnages de la cellule  Mecânica e Ondas Introdução ao Osciloscópio e ao Gerador de  デジタル無線式バックカメラ&モニター CRV-800    Manuale d`uso del Nokia 8600 Luna    Copyright © All rights reserved. 