user manual outdoor unit - sinclair air conditioners

image

Contents

1. M gt TEMP SENSOR TEMP SENSOR w EXHAUST OVERLOAD PROTECTOR uA SAT comp WH DPE YEGN vanene RINGL 3k BU YE RD A J X1 A U BU V YE W RD A T SENSOR OVC COMP COM INNER AP1 PRINTED CIRCUIT BOARD N1 HEAT B ibid is PE V V RD 12 X VT VT M1 PE YEGN EHE gt V T BOTTOM AV S PE PE PUT aaway FAN MOTOR HEATER VALVE 14 RATING LABEL SINCLAIR AIRCONDITIONER OUTDOOR UNIT Model ASH 09AIM2 PT Rated Voltage 220 240 V Cooling Capacity 2600W Heating Capacity 3000W Cooling Power Input 870W Heating Power Input 900W R410A Cooling Rated Input 1300W Refri Charge 0 70kg Heating Rated Input 1400W Sound Pressure Level SIdB A Maximum Allowable Pressure 4 3MPa Operating Pressure Discharge Side Suction Side 4 3 2 5MPa Manufactured Date Moisture Protection IPM Contains fluorinated greenhouse gases covered by the Kyoto Protocol TUV E IS09001 Sinclair Corporation Ltd 1 4 Argyll St London UK SINCLAIR AIR CONDITIONER OUTDOOR UNIT Model ASH 18AIM2 PT Rated Frequency 50Hz ye eating Capacity 5800W Cooling Power Input 1625W Heating Power Input 1760W Isolation I 5 R410A Cooling Rated Input 2650W Refri Charge 1 35ke Heating Rated Input 2650W Sound Pressure Level S6dB A Maximum Allowable Pres
2. Step two install drain joint Step three fix outdoor unit Only for cooling and heating 1 Place the outdoor unit on the unit support 1 Connect the outdoor drain joint into 2 Fix the foot holes of outdoor unit the hole on the chassis as shown in with bolts the picture below 2 Connect the drain hose into the drain vent foot holes foot holes nm drain vent B chassis Drain hose outdoor drain joint Installation of outdoor unit Step four connect indoor and outdoor pipes 1 Remove the screw on the right han dle of outdoor unit and then remove the handle screw handle EU 2 Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe gas valve 3 Pretightening the union nut with hand 4 Tighten the union nut with torque wrench by referring to the sheet below Hex nut diameter 9 52 Step five connect outdoor electric wire 1 Remove the wire clip connect the power connection wire and signal control wire only for cooling and heating unit to the wiring terminal according to the color fix them with screws 09 handle LUCI 717 yellow green POWER yellow green Indoor unit connection Indoor unit connection Installation of outd
3. Check if there is leakage with leakage detector With soap water If leakage detector is not available please use soap water for leakage detection Apply soap water at the suspected position and keep the soap water for more than 3min If there are air bubbles coming out of this position there s a leakage Check after installation e Check according to the following requirement after finishing installation Items to be checked Possible malfunction Has the unit been installed firmly The unit may drop shake or emit noise Have you done the refrigerant leakage It may cause insufficient cooling test heating capacity It may cause condensation and water dripping It may cause condensation and water dripping Is heat insulation of pipeline sufficient Is water drained well Is the voltage of power supply accord ing to the voltage marked on the nameplate It may cause malfunction or damaging the parts Is electric wiring and pipeline installed correctly It may cause malfunction or damaging the parts Is the unit grounded securely It may cause electric leakage It may cause malfunction or damaging the parts Does the power cord follow the speci fication Is there any obstruction in the air inlet It may cause insufficient cooling and outlet heating capacity The dust and sundries caused during installation are removed It may cause malfunction or damaging the parts The gas valve and liqui
4. USER S MANUAL MATRIX 2 SERIES outdoor unit ASH 09AIM2 PT ASH 13AIM2 PT ASH 18AIM2 PT ASH 24AIM2 PT AIR CONDITIONING Precautions WARNING e This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory ormental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved e Children shall not play with the appliance e Cleaning and user maintenance shall not be made by children without supervision e Do not connect air conditioner to multi purpose socket Other wise it may cause fire hazard e Do disconnect power supply when cleaning air conditioner Otherwise it may cause electric shock e Do not spray water on indoor unit It may cause electric shock or malfunction e Do not spill water on the remote controller otherwise the rem ote controller may be broken e Do not repair air conditioner by yourself It may cause electric shock or damage Please contact dealer when you need to re pair air conditioner e Do not block air outlet or air inlet It may cause malfunction e f you need to relocate the air conditioner to another place only the qualified person can perform the work Otherwise it may cause personal injury or damage e Do not step on top panel of outdoor unit or put heavy objects It may cause damage or person
5. pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note e Please contact the local agent for installation e Don t use unqualified power cord Selection of installation location Basic requirement Installing the unit in the following places maycause malfunction If it is un avoidable please consult the localdealer 1 The place with strong heat sources vapors flammableor explosive gas or volatile objects spread in the air 2 The place with high frequency devices such as welding machine medical equipment 3 The place near coast area 4 The place with oil or fumes in the air 5 The place with sulfureted gas 6 Other places with special circumstances 7 The appliance shall not be installed in the laundry Outdoor unit Select a location where the noise and outflow air emitted by the outdoor unit will not affect neighborhood 2 The location should be well ventilated and dry in which the outdoor unit won t be exposed directly to sunlight or strong wind 3 The location should be able to withstand the weight of outdoor unit 4 Make sure that the installation follows the requirement of installation dimension diagram 5 Select a location which is out of reach for children and far away from animals or plants If it is unavoidable please add the fence for safety purpose Requirements for electric connection Safety precaution Must follow the electric sa
6. see the fig 1 The drain plug consists of one 25 5 two kidney plugs Hose available commercially inner dia 16 The figures in this manual may be different with the material objects please refer to the material objects for reference j Didney holes Didney holes HD Didney holes 8 Fig 1 Vacuum pumping Open the piezometer com Close the vacuum pump Use vacuum pump Remove the valve caps on o0 the liquid valve and gas liquid valve piezometer valve and the nut of refri 2 gerant charging vent gas valve RA Connect the charging hose refrigerant charging 22 valve cap of piezometer to the refri vent y gerant charging vent of gas nut of refrigerant 7 valve and then connect the charging vent other charging hose to the C727 vacuum pump vacuum pump inner hexagon pletely and operate for 10 15min to check if the pressure of piezometer re mains in 0 1 and maintain this status for 1 2min to check if the pres sure of piezometer remains in 0 1MPa If the pressure decreases there may be leakage Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner Tighten the screw caps of valves and refrigerant charging vent Reinstall the handle Leakage detection 1 2 With leakage detector
7. al injury e Do not extend fingers or objects into air inlet or air outlet It may cause personal injury or damage e Air Conditioner should be properly grounded Incorrect ground ing may cause electric shock e Do install the circuit break If not it may cause malfunction e Installation and maintenance must be performed by qualified pr ofessionals Otherwise it may cause personal injury or damage 1 Precautions Working temperature range Indoor side DB WB C Outdoor side DB WB C 32 23 48 26 Maximum heating 24 18 NOTICE e The operating temperature range outdoor temperature for cooling is 15 C 48 C The operating temperature range outdoor temperature for heating is 20 C 24 C Parts Name Outdoor Unit air inlet handle air outlet NOTICE Actual product may be different from above graphics please refer to actual products Installation dimension diagram i ne obstruction Space to t dul 8 F em wall MEER 5 F L A CQ 1 S GE id At least 50cm EET f e er SS Lov Sages to the Obstruction SSG N Tools for installation 1 Level meter 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum
8. d valve of It may cause insufficient cooling connection pipe are open completely heating capacity Test operation 1 Preparation of test operation e The client approves the air conditioner e Specify the important notes for air conditioner to the client 2 Method of test operation e Put through the power press ON OFF button on the remote controller to start operation e Press MODE button to select AUTO COOL DRY FAN and HEAT to check whether the operation is normal or not e f the ambient temperature is lower than 16 C 61 F the air conditioner can t start cooling 10 Configuration of connection pipe 1 Standard length of connection pipe e 5m 7 5m 8m 2 Min length of connection pipe is 3m 3 Max length of connection pipe and max high difference Cooling Max height Cooling du Max height of connec of connec capacity tion pipe difference capacity ten aize difference 5000Btu h 24000Btu h 1465W UE 7032W 22 E 7000Btu h 28000Btu h 2051W 8204W 30 10 9000Btu h 36000Btu h M 2637W 10548W 12000Btu h 42000Btu h 3516W 12306W 18000Btu h 48000Btu h 5274W 14064W 4 The additional refrigerant oil and refrigerant charging required after prolonging connection pipe e After the length of connection pipe is prolonged for 10m at the basis of standard length you should add 5ml of refrigerant oil for each additional 5m of connection pipe e The calculation method of addi
9. fety regulations when installing the unit 2 According to the local safety regulations use qualified power supply circuit and air switch Make sure the power supply matches with the requirement of air conditioner Unstable power supply or incorrect wiring or malfunction Please install proper power supply cables before using the air conditioner Properly connect the live wire neutral wire and grounding wire of power socket Be sure to cut off the power supply before proceeding any work related to electricity and safety Do not put through the power before finishing installation If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The temperature of refrigerant circuit will be high please keep the interconnec tion cable away from the copper tube The appliance shall be installed in accordance with national wiring regulations Grounding requirement Ts The air conditioner is the first class electric appliance It must be properly grounding with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock The yellow green wire in air conditioner is grounding wire which can t be used for other purposes The grounding resistance should comply with national electric safety regulations The appliance must be positioned so that the plug is accessib
10. le An all pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring Including an circuit break with suitable capacity please note the following table Air switch should be included magnet buckle and heating buckle function it can protect the circuit short and overload Caution please do not use the fuse only for protect the circuit Circuit break capacity 09 13K 18 24K Installation of outdoor unit Step one fix the support of outdoor unit select it according to the actual installation situation 1 Select installation location according to the house structure 2 Fix the support of outdoor unit on the selected location with expansion screws Note e Take sufficient protective measures when installing the outdoor unit e Make sure the support can withstand at least four times of the unit weight e he outdoor unit should be installed at least 3cm above the floor in order to install drain joint e For the unit with cooling capacity of 2200W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacity of 10000W at least 3cm above the floor 16000W 10 expansion screws are needed
11. ndon U ENERGY LABEL Evepyeia ENERG OO Model ASH 09AIM2 PT SEER Qa kw 2 7 kw 3 0 2 8 3 8 SEER 6 1 SCOP 4 6 4 0 2 8 kWh annum 155 kWh annum 913 980 2850 ENERGIA EHEPTV8 ENEPTEIA ENERGIJA ENERGY ENERGIE ENERGI 626 2011 Oo ENERG 60 Model ASH 18AIM2 PT kw 5 2 SEER 6 1 kWh annum 298 4 5 6 2 SCOP 4 5 4 0 3 1 kWh annum1649 1575 4200 o 6 ENERGIA ENERGIJA ENERGY ENERGIE ENERGI 626 2011 16 Oo ENERG Model ASH 13AIM2 PT kw 3 5 SEER 6 1 kWh annum 201 kw 3 0 3 2 4 0 SCOP 4 8 4 0 2 8 kWh annum 875 1120 3000 63 ENERGIA EHEPTVR ENEPTEIA ENERGIJA ENERGY ENERGIE ENERGI 626 2011 ENERG eVEpyeia Model ASH 24AIM2 PT kw 6 4 SEER 6 1 kWh annum 367 kw 6 0 5 8 SCOP 4 8 v ENERGIA ENEPTEIA ENERGUA ENERGY ENERGIE ENERGI 626 2011 NOTE CONCERNING PROTECTION OF ENVIRONMENT service life but must be taken to a collection station for the recycling of electrical and electronic devices The symbol on the product the Operating instructions or the packaging indicate such disposal procedures The materials are recyclable in accordance with their respective symbols By means of re use material recycling or any other form of recycling old appliances you are making an important contribution to the protection of our environment Please ask your local co
12. oor unit 2 Fix the power connection wire and signal control wire with wire clip only for cooling and heating unit Note e After tighten the screw pull the power cord slightly to check if it is firm e Never cut the power connection wire to prolong or shorten the distance Step six neaten the pipes EN LII 1 The pipes should be placed along the wall bent reasonably and hidden possibly Min semidiameter of bending the pipe is 10cm 2 If the outdoor unit is higher than the wall hole you must set a U shaped curve in the pipe before pipe goes into the room in order to prevent rain from getting into the room A drain hose Outdoor Condensate Drainage 18K MC UNIT During heating operation the condensate and defrosting water should be drained out reliably through the drain hose SK Install the outdoor drain connector in a 25 hole the base plate and attach the drain hose to the connector so that the waste water formed in the outdoor unit be drained out The hole diameter 25 must plugged 24K MD UNIT Whether to plug other holes will be determined by the dealers to actual conditions i A Wf 7 Didney holes Drain water hole Bottom frame E The 18K MC 24K MD UNIT drainage hole consists of two 25 and Drain plug two kidney holes
13. sure 4 3MPa Operating Pressure Discharge Side Suction Side 4 3 2 5MPa Manufactured Date Moisture Protection Contains fluorinated greenhouse gases covered by the Kyoto Protocol CE T E so Sinclair Corporation Ltd 1 4 Argyll St London U 15 AIR CONDITIONER OUTDOOR UNIT Model ASH 13AIM2 PT Rated Voltage 220 240 V Cooling Capacity 3500W Heating Capacity 4000W Climate Type Cooling Power Input 1170W Heating Power Input 1200W Isolation I R410A Cooling Rated Input 1400W Refri Charge 0 85 Heating Rated Input 1550W Sound Pressure Level 53dB A Maximum Allowable Pressure 4 3MPa Operating Pressure Discharge Side Suction Side 4 3 2 5MPa Manufactured Date Moisture Protection IP24 Contains fluorinated greenhouse gases covered by the Kyoto Protocol TW X som MI Sinclair Corporation Ltd 1 4 Argyll St London UK SINCLAIR AIR CONDITIONER OUTDOOR UNIT Modd ASH 24AIM2 PT Heating Capacity 7000W Cooling Power Input 2180W eee EN P R410A Cooling Rated Input 2650W Refri Charge 1 80ke Heating Rated Input 2800W Sound Pressure Level 58dB A Maximum Allowable Pressure 4 3MPa Operating Pressure Discharge Side Suction Side 4 3 2 5MPa Manufactured Date Moisture Protection IPM Contains fluorinated greenhouse gases covered by the Kyoto Protocol TVZ som MINNAN Sinclair Corporation Ltd 1 4 Argyll St Lo
14. the indoor connection pipe and outdoor valve install the union nut on the pipe smooth surface improper expanding Tf Yr wr wr lt gt leaning damaged crack uneven surface thickness the length is equal 13 ELECTRIC SCHEMATIC DIAGRAM ASH 09AIM2 PT outdoor ASH 13AIM2 PT outdoor MID ISOLATION SHEET Tse TEAL SENSOR TEM SENSOR TEM SENSOR RTI OUTROON EXHAUST RT L NY YEGN LX1 2 AWAY AP2 HEAT2 HEAT 1 ELECTRIC BOX YEGN RD t MOTOR v HEATER HEATER YEGN CHASSIS COMP a NOTE The electrical Motor ground only heaters are a the optional iron shell motor ASH 18AIM2 PT outdoor ASH 24AIM2 PT outdoor ZN WARNING Please don t touch any terminal when the voltage of terminal P DC and N DC at AP1 is higher than 30V to prevent the risk of electric shock 1 YEGN p PE TERMINAL Bis BLOCK i w BU CA 2 gt BN 3 BU LT BN BU lye LBU XT1 MAGNETIC YEGN RING L POWER
15. tional refrigerant charging amount on the basis of liquid pipe Additional refrigerant charging amount prolonged length of liquid pipe x additional refrigerant charging amount per meter e Basing on the length of standard pipe add refrigerant according to the requirement as shown in the table The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet 11 Configuration of connection pipe Additional refrigerant charging amount for R410A and R134a 12 Pipe expanding method Note Improper pipe expanding is the main cause of refrigerant leakage Please expand the pipe according to the following steps A Cut the pipe e Confirm the pipe length according to the distance of indoor unit and outdoor unit e Cut the required pipe with pipe cutter E Expand the port e Expand the port with expander X burr Li NW Note e A is different according to the diameter please refer to the sheet below B Remove the burrs e Remove the burrs with shaper and prevent the burrs from getting into the pipe i F Inspection e Check the quality of expanding port If there is any blemish expand the port again according to the steps above C Put on suitable insulating pipe D Put on the union nut e Remove the union nut on
16. uncil where your nearest disposal station is located INFORMATION CONCERNING USED REFRIGERANT MEDIUM This product must not be disposed of via normal household waste after its This unit is containing fluorinated gases included in the Kyoto protocol The maintanance and the liquidation must be carried out by qualified personel Type of refrigerant RA10A The composition of the cooling medium R410A 50 HFC 32 50 HFC 125 The quantity of the refrigerant please see the unit label The value GWP 2088 GWP Global Warming Potential In case of quality problem or other please contact your local supplier or authorized service center Emergency number 112 PRODUCER Producer SINCLAIR CORPORATION Ltd 1 4 Argyll St London W1F 7LD UK www sinclair eu com This product was manufactured in China Made in China REPRESENTATIVE TECHNICAL SUPPORT NEPA spol s r o Purkynova 45 612 00 Brno Czech Republic Tel 420 541 590 140 Fax 420 541 590 124 www nepa cz klimatizace nepa cz 4 aay

Download Pdf Manuals

image

Related Search

Related Contents

TYPE-T  Sachtler Video 15 SB Manual - MEDIA TV Video Systeme GmbH    Method for analyzing printer faults  NEWSLETTER N°16 Septembre 2012  to open in a new window  Bedienungsanleitung Hochfrequenzlader BHFB 05 Art. 120780  Buffalo TeraStation Pro II iSCSI 1.0TB  l`ecole  PASW® Data Preparation (Vorbereitung von Daten) 18  