1. Changing the basic value The basic value can be adapted as follows in the event of different exposure conditions 1 Setthe large patient symbol to the middle range up per jaw premolar lower jaw molar of the object se lection switch 1 Press the D key approx 4 sec until the ready for operation LED and Digital flash Let go of the D key The basic value can be increased step by step or decreased by turning the object selection switch Press the D key to save the value Set the object selection switch 5 back to the start ing position The basic value is displayed 3 steps higher If you do not want to save the value do not press the D key You must then switch the unit OFF and then ON again Adjacent example Changing the basic value in digital radiography from 8 cone to 12 cone 3 steps higher 23 12 Care 12 1 Cleaning 12 12 1 Care Cleaning Disinfecting 24 Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral Handle the highly sensitive X ray sensor with its cable carefully When cleaning do not pull on the connection cable Do not kink the cable o NOTE Please also make sure to observe the Care Instruction for SIDEXIS Intraoral Sensors Part No 59 74 329 Remove dirt and disinfectant residue regularly using a mild commercially available cleaning agent Make sure that no liquids c
2. Import Export Select X ray component Status Name L Intraoral plug in card KIO ay Room 1 XRay Room 2 XRay Room Vee 20 To make the system ready for exposure SIDEXIS must be called up on the corresponding computer You must initially register a patient in the SIDEXIS pro gram If you want to make a single exposure click on the XI button To make multiple exposures for the same patient select the Multiple exposure subitem in the menu bar The Select X ray component window then appears If several X ray units or acquisition units are installed in the practice you must then select the required unit by clicking in the Status column indicated by a blue square Acquisition units identified with a question mark are pos sibly not switched on After confirmation the unit is connected Q nore If only one station has been set up this dialog is skipped You will find detailed descriptions of these operating steps in the SIDEXIS User Manual 60 87 816 D 3334 D 3334 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral PC screen Ready for intraoral X ray 60 87 816 D 3334 D 3334 201 01 13 02 10 Making the system ready for exposure 8 2 Switching the unit on Following buildup of the connection the message Place the sensor is displayed briefly After a few seconds the system is ready for the
3. The Dental Company SIDEXIS Intraoral Operating Instructions onn girona Dear Customer Maintenance Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral Thank you for purchasing your new Intraoral X ray prod uct from the SIDEXIS family This product enables the digital image acquisition of intraoral X rays For this unit we have also provided the technical docu mentation Keep this documentation nearby for quick and easy ref erence in the Federal Republic of Germany in the X ray System book In order to protect your warranty rights please fill out the Installation Report Warranty Passport provided together with the technician immediately after installa tion of the system These Operating Instructions cover the operation of the Wall Model X ray Box the Universal sensor and the Full Size sensor Read the Operating Instructions to familiarize yourself with the product before taking X rays on the patient Be sure to observe the currently valid Radiation Protection Guidelines and the Safety Notes in these Operating Instructions These Operating Instructions assume a thorough famil iarity with the SIDEXIS software In the Federal Republic of Germany the system integra tor is required to fill out the enclosed declaration of con formity in accordance with the Medical Device Directive Your SIDEXIS Team To ensure the safety of the patient the operators and third
4. s at 60 70 kV and 8 Tube 11 3 Operating and display elements 3 1 VVall model X ray box Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral Operating and display elements Wall model X ray box Sirona ET h II 1 2 345 1413 6 7 8 e 4 12 10 11 12 DJ m o 10 11 12 13 14 Universal sensor 20 x 30 mm active area plug marked gray Full Size sensor 26 x 34 mm active area plug marked blue Signal LED for readiness to operate Signal LED for Universal sensor Signal LED for Full Size sensor Holder for sensor removable for cleaning Suspension device for excess sensor cable length X ray box for image acquisition as wall model Main ON OFF switch Socket for sensor plug Round plug on the relevant sensor lead Name plate Symbol f Application component of type BF Symbol ATTENTION Please read accompanying papers 60 87 816 D 3334 D 3334 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral 4 Accessories 4 Accessories 3 1 Wall model X ray box Test phantom for constancy test REF 51 68 062 X ray field limitation blue with twist grip for Full Size sensor REF 46 81 974 X ray field limitation black with twist grip for Universal sensor REF 60 00 579 Sensor holder set with sight rings and guide rods from DE
5. 34 mm Full Size 20 x 30 mm Universal Size 30 93 x 40 96 x 7 0 mm Full Size 25 6 x 36 9 x 6 8 mm Universal 0 40 C 10 C to 70 C on dispatch in original packaging 40 C to 70 C for max 48 h 60 87 816 D 3334 D 3334 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral 3 Image acquisition Wall model X ray box US version Worldwide version Type of protection against electrical shock Degree of protection against penetration of water Operating mode 4 Minimum requirements for the PC systems Hard disk RAM Drives Operating system Graphics system Network 2 Technical data 1 3 Concerning the physics of electrostatic charges 120 V 50 60Hz max 40W 100 240V 50 60 Hz max 40W unit of Protection Class I normal unit without protection against penetration of water continuous operation 2 GByte database 50 MByte SIDEXIS installation at least 64 MB CD ROM 3 5 diskette one per system network MOD drive min 640 MByte one per system net work Windows 98 Windows NT 4 0 Service Pack 5 Resolution at least 1024 x 768 pixels color depth at least 8 bits 10 100 MBit Ethernet 5 Requirement for the intraoral X ray tube assembly 60 87 816 D 3334 D 3334 201 01 13 02 Multipulse units mAs product These data apply correspondingly for sin gle pulse units or other cone lengths 0 14 1 4 m
6. List of Contents Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral 60 87 816 D 3334 D 3334 201 01 13 02 Sirona Dental Systems GmbH 1 VVarning and safety information Operating Instructions SIDEXIS Intraoral 1 1 General safety information VVarning and safety information General safety information Intended use This unit is not to be operated in areas where an explo sion hazard exists Symbols used Observe accompanying documents on name plate Maintenance and repair As manufacturers of electromedical equipment we can assume responsibility for the safety properties of the System in particular only if maintenance and repairs on the system are performed by us or by agencies we have expressly authorized to perform these and if compo nents affecting safe operation of the system are replaced by original spare parts in case of failure We suggest that you request a certificate showing the nature and extent of the work performed from those who carry out such work and specify that the certificate show any changes in rated parameters or working ranges as well as the date the name of the firm and a signature For product safety reasons this product may be operated only with original Sirona accessories or accessories of third parties expressly approved by Sirona The user assumes the risk for the use of nonapproved accesso ries impair the functional reliability of the system e g patient safety and EMC
7. The X ray sensor AN CAUTION When the highly sensitive X ray sensor is notin use al ways hang it in its holder The round plug 11 must be plugged into the socket pro vided for it 10 The red dot A must point to the front The excess length of the sensor cable B can be hooked into the suspension device 7 NOTE Since the plug is connected to the housing it must be plugged in before placing the sensor NOTE Please also make sure to observe the Care Instruction for SIDEXIS Intraoral Sensors Part No 59 74 329 Switching the unit on A CAUTION If an acquisition unit is switched off briefly a few seconds waiting time are required to completely discharge the in Wall model X ray box ternal energy store 345 Wall model X ray box The unit is switched on from the main switch 9 on the bottom of the box I After switching on an automatic system self test exe o cutes The three LED 3 4 5 signal this by a running light o Du Sirona The green signal LED 3 then shows that the unit is ready for operation 60 87 816 D 3334 D 3334 201 01 13 02 17 9 System statuses 8 2 Switching the unit on System statuses The three signal LEDs serve for indicating the system statuses 18 Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral The operating messages of the acquisition units
8. according to tooth region Lovver javv anterior Upper javv molars Upper javv canine 1 lovver Lovver javv canine jaw molars Upper jaw anterior e 7 Children 0 04 s NOTE Please check according to exposure region the time set ting on the digital time display of the unit before the expo sure Occlusal exposure The above exposure times are doubled when a 12 SSD cone and Sirona Full Size Universal X ray sensors are used HELIODENT DS up to Serial No 15863 wall model and 4415 ceiling model Possible exposure times epep ep ep ipa papspapapepehupapapapapa Recommended exposure times with 8 SSD cone The recommended exposure times are limited to the fol and Sirona Full Size Universal X ray sensor lowing values from the number of possible exposure times papapapa Q NOTE The previous orientation to the tooth symbols for setting the exposure time is no longer valid for these sensors 60 87 816 D 3334 D 3334 201 01 13 02 27 13 Exposure values Sirona Dental Systems GmbH 13 2 HELIODENT DS up to Serial No 15863 wall model and 4415 ceiling model Operating Instructions SIDEXIS Intraoral Classification of the recommended exposure times according to tooth region Lower jaw anterior Upper jaw molars Lower jaw canine Upper jaw canine lower jaw molars Upper jaw anterior Occlusal exposure LI i Children o NOTE Please check according to exposure reg
9. are shown below Further statuses not shown here represent information for service or maintenance purposes Self test after switching on Running light of the three signal LEDs System message e g network not ready The green signal LED flashes A system error has occurred Please call your service technician Ready for operation The green signal LED lights up Making an exposure No Sensor plugged in The green signal LED lights up and the two yellow signal LEDs flash simultaneously 4 2 Sensor plugged in If the sensor cable is plugged in only the corresponding signal LED flashes until the system is ready for expo sure 60 87 816 D 3334 D 3334 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral Slow flashing rate TO Q Fast mm NE NEM E o NE E D SO a flashing rate mm mum NEM NEM NEMO REN NES ENS n 60 87 816 D 3334 D 3334 201 01 13 02 9 Systemstatuses 8 2 Switching the unit on 4 3 Ready for exposure with plugged in sensor cable The readiness for operation status message is gen erated on the PC by SIDEXIS The green LED lights up together with the yellow signal LED for the corresponding sensor 4 4 Image transfer to the database During the transfer process the green signal LED and the yellow signal LED of the corresponding sen sor flash slowly alternatingly When the image is transferred to the database the unit switches automa
10. compatibility The person who makes the extension which is not expressly approved by Sirona undertakes the warranty for the functional reliability of the system ATTENTION If extensions are made to the PC this can Combination with other equipment Permissible combinations are defined by the system administrator in the declaration of conformity The declaration of conformity is included with the techni cal documents Electromagnetic compatibility EMC The SIDEXIS Intraoral complies with the requirements of IEC 60601 1 2 2001 Medical electrical devices are subject to special precau tionary measures regarding EMC They must be installed and operated as specified in the document Installation Requirements Portable and mobile HF communication devices can influence medical electrical equipment The use of mobile telephones in the practice or hospital area there fore must be prohibited Please also observe the ESD protective measures in Chapter 1 2 60 87 816 D 3334 D 3334 201 01 13 02 5 1 Warning and safety information 1 1 General safety information Allocation of acquisition system to patient Hygiene information Identification of warning and safety information Interference with electronic devices worn on the body of the patient Maintenance performed by the operator Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral In the course of the dental practice procedure in order to guar
11. expo Sure The message Waiting for exposure appears in the dialog box In addition the green indicator in the window starts to flash Readiness for exposure is now signalled on the acquisi tion unit as well The yellow signal LED 4 or 5 assigned to the corre sponding sensor lights up in addition to the green signal LED 3 Assemble the holder combination for right angle tech nique intended for the relevant type of exposure accord ing to the Operating Instructions fit the required hygiene protection and place it with the X ray tube assembly and the sensor on the patient The exposure can now be made with the X ray tube assembly For exposure times refer to Chapter 11 Exposure val ues If no radiation is released the unit status changes after 15 minutes from ready for exposure back to ready for operation A CAUTION If no readiness dialog appears and the display in the dia log does not flash or the signal LEDs on the acquisition unit do not light up then no X ray exposures may be tak en on the patient until the cause of this problem is recti fied After the exposure the LED assigned to the sensor starts to flash alternatingly with the operating indicator LED 3 and the data are transferred A CAUTION The unit may not be switched off until the data transfer is completed This status is shown by the operating indica tor LED 3 lighting up continuously 21 11 Exposure control adap
12. parties equipment inspections and maintenance work must be carried out at specified intervals in order to guarantee the operational safety and functional reliability of your product It is the responsibility of the operator to ensure that the inspections and maintenance work are carried out In the event that the operator fails to fulfil the obligation to carry out inspections and maintenance work or ignores error messages Sirona Dental Systems GmbH or their contracted dealer cannot assume liability for any damage attributable to this 60 87 816 D 3334 D 3334 201 01 13 02 Sirona Dental Systems GmbH List of Contents Operating Instructions SIDEXIS Intraoral List of Contents u Warning and safety information nepunsacasas animi nsn paro aic s c COR KH ae ET REOR B RR 5 1 1 General safety informalion eccentric st dt ie a Ee n 5 1 2 ESD PS 8 1 3 Concerning the physics of electrostatic charges anha an nana na ana ann nanen nese tere enter e tetit e eee eee ee eee ee eee nnns 8 Technical GA ta m ees 10 Operating and display elements 1 nana unin nene ce reres e nonen sene nore eee e ne eee eee n ene eren nen eee esen nes 12 3 1 li rlu P gridi cmE iia EEE 12 P esllQ l M H 13 en E 14 Hygiene protection T 15
13. 334 201 01 13 02 The recommended exposure times are limited to the fol lowing values from the number of possible exposure times papapapa A CAUTION The previous orientation to the tooth symbols for setting the exposure time is no longer valid for these sensors Upper jaw molars Lower jaw molars Upper jaw canine Occlusal exposure Oo NOTE Please check according to exposure region the time set ting on the digital time display of the unit before the expo surel The above exposure times are doubled when a 12 SSD cone and Sirona Full Size Universal X ray sensors are used 31 13 Exposure values 13 5 HELIODENT 70 not USA versioni Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral HELIODENT 70 not USA version Recommended exposure times with 8 SSD cone and Sirona Full Size Universal X ray sensor Classification of the recommended exposure times according to tooth region Lower jaw anterior Lower jaw canine Upper jaw anterior e i Children 32 The recommended exposure times are limited to the fol lowing values from the number of possible exposure times II A CAUTION The previous orientation to the tooth symbols for setting the exposure time is no longer valid for these sensors Upper jaw molars Lower jaw molars Upper jaw canine Occlusal exposure o NOTE Please check according to exposure region the time set ting on t
14. 6 D 3334 D 3334 201 01 13 02 1 VVarning and safety information 1 1 General safety information It generally applies that any disposal of this product must comply with the relevant national regulations Please observe the regulations applicable in your country Within the European Economic Community Council Directive 2002 96 EU WEEE requires environmentally sound recycling disposal of electrical and electronic devices Your product is marked with the adjacent symbol Dis posal of your product with domestic refuse is not compatible with the objectives of environ mentally sound recycling disposal The black bar underneath the garbage can symbol means that it was put into circulation after Aug 13 2005 see EN 50419 2005 Please note that this product is subject to Council Direc tive 2002 96 EU WEEE and the applicable national law of your country and must be recycled or disposed of in an environmentally sound manner The X ray tube assembly of this product contains a tube with a potential implosion hazard a small amount of beryllium a lead lining and mineral oil Please contact your dealer if final disposal of your prod uct is required 1 Warning and safety information 1 2 ESD protective measures ESD protective measures KALAS Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral ESD is the abbreviation for ElectroStatic Discharge A CAUTION Connector pins or sockets beari
15. NTSPLY RINN REF 58 58 522 Hygiene protection for Full Size sensor 500 pcs REF 51 69 110 Hygiene protection for Universal sensor 500 pcs REF 58 06 497 NOTE Not all accessories described here are included in the scope of supply 60 87 816 D 3334 D 3334 201 01 13 02 13 5 Collimation 3 1 VVall model X ray box li Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral 46 81 974 blue for Full Size sensor 60 00 579 black for Universal sensor Check whether the diaphragm provided is inserted in the HELIODENT cone Insert the corresponding diaphragm with twist grip depending on the sensor being used i e blue for Full Size sensor and black for Universal sensor Adjust the window of the collimator according to the alignment of the sensor Use of the collimator in the cone of the HELIODENT gives a rectangular radiation area adapted to the size of the sensor Q nore Use the collimator only with a sensor holder Set 58 58 522 14 HELIODENT DS HELIODENT MD Diaphragm 1 blue Order No 46 81 974 or black Order No 60 00 579 for digital X ray sensors Push the twist grip 3 over the collimator 1 and bring the snap hooks 4 into the mid position The sight ring A must be fitted with its recesses on the four corners of the collimator 1 Sensor holder set 5 with sight rings and guide rods for different exposur
16. Use of the X ray Sensor auus dd dd IL KDE RR 16 Preparations for the expoSUL uiuis racio nini dra E ERE RT TCR RT CHR 17 8 1 ILS nda aa vde vid debit v re nd den dd teen Oa t hindi eni 17 82 Switching the UNION m 17 System STALUSOS ja 18 Making the system ready for expoSUFO 1 nana nane nes anen enen er eee ee nene none ne sere eee renome nene nenen 20 Exposure control adapting exposure data eee eee ne nene nenen eee se 22 TAA Expos re Control nises n ee eet nee ee yet ee She e tepert oe 22 11 22 Adapting exposure data eei sht pod nd ini d r mvesh e pi eunte Tene ao deno Ee ndier shtyn 22 GP e 24 12 15 SGJSANIN E EPE E E E T t ME dI Denier 24 12 2 Disiniectin diva ten tie ten ao et eot ese det a e oce de Bee Peso ee 24 Exposure VE LES sq neama asd banaa anina rana iana ndi aniaananinrannu masas ani 26 13 1 HELIODENT DS as from Serial No 15864 wall model and 4416 ceiling model 26 13 2 HELIODENT DS up to Serial No 15863 wall model and 4415 ceiling model 27 13 3 HELIODENT VANO sesa socio ues reuerti dk nti ata reve ane 30 184 HELODBENT MD iii pie Hora ERR RE Fue e era de Husain hh u DH Ae 31 13 5 HELIODENT 70 not USA versionl sesssssssssseeeeenneenen nennen nenen rennen trennen nnne nennen 32 60 87 816 D 3334 D 3334 201 01 13 02 3
17. an penetrate through the ven tilation slots Immediately wipe away medicaments from the surface Do not use agents containing phenol peracetic acid peroxide and other oxygen cleaving agents sodium hypochlorite and iodine cleaving agents PC and screen For cleaning the PC and the screen please refer to the Service Instructions for these components The wall model X ray box both sensors and the wall holder for the sensors can be disinfected by wiping 60 87 816 D 3334 D 3334 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral ON IZ gt AS K Qn Wy rat NN NS 60 87 816 D 3334 D 3334 201 01 13 02 12 Care 12 2 Disinfecting The sensor holders sight rings and guide rods can be sterilized See the instructions from DENTSPLY RINN A CAUTION Do not thermodisinfect the Universal and the Full Size sensors with connection cable do not immerse them in disinfectant solutions do not disinfect them with radiation and do not sterilize them 25 13 Exposure values 13 1 HELIODENT DS as from Serial No 15864 wall model and 4416 ceiling model Exposure values for Sirona Full Size Universal X ray sensors Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral Only a few exposure values are sufficient for the highly sensitive Sirona Full Size and Universal X ray sensors The exposure values for X ray senso
18. antee reliable assignment of the X ray exposures to the patient data stored by SIDEXIS it must be guaran teed that the unequivocal assignment of the acquisition system to the examined patient is assured The protective covers must be exchanged for each new patient and the sterilizable accessories must be steri lized to prevent any transmission of infective agents which might cause serious illnesses Suitable hygienic measures must be taken to prevent cross contamination among patients users and other persons To avoid personal injury and material damage also observe the warning and safety instructions given in these Operating Instructions These are specially identi fied with ATTENTION To avoid failures of electronic devices and data memo ries such as radio controlled clocks and telephone cards these must be removed before the X ray expo sure If a second protective ground wire connection is speci fied in the installation instructions to be used the opera tor must ensure that no changes are made to the second protective ground wire connection as shown in the pic ture V DIT Example No further maintenance measures are required on the part of the operator The operator must ensure that all components are in undamaged condition cables sensors housing parts 60 87 816 D 3334 D 3334 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral Disposal 60 87 81
19. bserve the Care Instruction for SIDEXIS Intraoral Sensors Part No 59 74 329 60 87 816 D 3334 D 3334 201 01 13 02 15 7 Use of the X ray sensor 3 1 VVall model X ray box Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral Use of the X ray sensor Wis l X SNB S AN N N NEN WC NIN NI S Nx Sen o NOTE The sensors illustrated are representative of all Sirona X ray sensors The X ray sensor is placed according to the known prin ciples of the half angle or right angle technique Half angle technique without collimator According to the size of the tooth or position of the area to be exposed place the X ray sensor vertically or hori zontally into the mouth of the patient The patient can fix the sensor by independently holding it as usual 16 Right angle technique For reasons of dose reduction for the right angle tech nique we recommend using the holder system supplied Use of the different sensor holders with guide rods and sight rings with the right angle technique is described in separate operating instructions from Rinn Q nore For reasons of clarity no hygiene protection is shown in these figures 60 87 816 D 3334 D 3334 201 01 13 02 Sirona Dental Systems GmbH 8 Preparations for the exposure Operating Instructions SIDEXIS Intraoral 8 1 The X ray sensor Preparations for the exposure
20. e positions REF 58 58 522 Q nore The holder set for the right angle technique is part of the sensor set and is described there in separate operating instructions 60 87 816 D 3334 D 3334 201 01 13 02 Sirona Dental Systems GmbH 6 Hygiene protection Operating Instructions SIDEXIS Intraoral 3 1 Wall model X ray box Hygiene protection A CAUTION Use only the hygiene protection sleeves from Sirona Before every application on a new patient the sensor must be provided with a new hygiene protective sleeve Do not use the hygiene protection sleeves more than once Be careful not to kink the sensor lead when sliding on the hygiene protection Use the hygiene protection intended for use with your sensor type Hygiene protection for Universal sensor 500 pcs REF 58 06 497 Hygiene protection for Full Size sensor 500 pcs REF 51 69 110 When the RWT holder set from DENTSPLY RINN is used the hygiene protection between sensor and holder is provided according to the holder used A CAUTION Do not slide the hygiene protection over the entire holder with sensor Cp NOTE Take care that the connection cable from the sensor to the personal computer is led out from the mouth of the patient in such a way that the patient cannot bite into the cable With respect to the hygiene of the holder system observe the instructions from DENTSPLY RINN NOTE Please also make sure to o
21. he digital time display of the unit before the expo sure The exposure time is displayed by the orange mark on the dial The above exposure times are doubled when a 12 SSD cone and Sirona Full Size Universal X ray sensors are used 60 87 816 D 3334 D 3334 201 01 13 02 We reserve the right to make any alterations which may be due to technical improvements O Sirona Dental Systems GmbH 1999 2008 Sprache englisch Printed in Germany D 3334 201 01 13 02 11 2008 Nr 110 759 Imprim en Allemagne EE m c X m o ee mem uq eee Sirona Dental Systems GmbH in the USA FabrikstraBe 31 Sirona Dental Systems LLC Order No 60 87 816 D 3334 64625 Bensheim 4835 Sirona Drive Suite 100 Germany Charlotte NC 28273 vvvvyv sirona com USA
22. ion the time set ting on the digital time display of the unit before the expo sure The above exposure times are doubled when a 12 SSD cone and Sirona Full Size Universal X ray sensors are used 60 87 816 D 3334 28 D 3334 201 01 13 02 Sirona Dental Systems GmbH 13 Exposure values Operating Instructions SIDEXIS Intraoral 13 2 HELIODENT DS up to Serial No 15863 wall model and 4415 ceiling model Exposure time settings The following diagrams show as examples the exposure time settings for the Sirona Full Size and Universal X ray sensors on the HELIODENT DS up to Serial No 15863 wall model and 4415 ceiling model Setting for adult patient Setting for adult patient lower upper anterior tooth upper premolar lower upper molar lower premolar for 8 cone occlusal exposure for 8 cone 0 06 0 08 Setting for child Setting for child lower upper anterior tooth upper premolar lower upper molar lower premolar for 8 cone occlusal exposure for 8 cone o m PEM 0 05 Setting for adult patient E Setting for adult patient lovver upper anterior tooth upper premolar lower upper molar lower premolar for 12 cone occlusal exposure for 12 cone 0 Se 1 2 a Setting for child Setting for child lower upper anterior tooth upper premolar lower upper molar lower premolar for 12 cone occlusal exposure for 12 cone c3 nu jum 60 87 816 D 3334 D 3334 201 01 13 02 29 13 Exp
23. ity than with a high air humidity and higher with synthetic materials than with natural materials clothing floor coverings The following rule of thumb can be applied to gain an overview of the compensating voltages resulting from an electrostatic discharge An electrostatic discharge is e perceptible at 3000V or higher e audible at 5000V or higher cracking crackling e visible at 10 000V or higher arc over The compensating currents resulting from these dis charges have a magnitude of 10 amperes They are not hazardous for humans because they last for only several nanoseconds 60 87 816 D 3334 D 3334 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral 60 87 816 D 3334 D 3334 201 01 13 02 1 VVarning and safety information 1 3 Concerning the physics of electrostatic charges Voltage differences exceeding 30 000 volts per centi menter may lead to a charge compensation electro static discharge lightning arc over Integrated circuits logical circuits and microprocessors are used in order to enable a wide variety of functions in a dental X ray CEREC system The circuits must be miniaturized to a very high degree in order to include as many functions as possible on these chips This leads to layer thicknesses with a magnitude of several ten thou sandths of a millimeter It is obvious that integrated circuits which are connected to plugs leading outside of the unit via cables are
24. ng ESD warning labels must not be contacted or interconnected without ESD protective measures ESD protective measures include e Procedures for preventing electrostatic charges e g via air conditioning air moistening conductive floor coverings and nonsynthetic clothing e Discharging the electrostatic charges of your own body on the frame of the UNIT the protective ground wire or large metallic objects e Connecting yourself to ground using a wrist band We therefore recommend that all persons working with this system be instructed on the significance of this warning label Furthermore they also should receive training in the physics of electrostatic discharges which can occur in the practice and the destruction of elec tronic components which may result if such components are contacted by electrostatically charged USERS The content of this training is specified in Chapter 1 3 Concerning the physics of electrostatic charges 1 nanosecond 11 1 000 000 000 second 1 billionth of a second ESD is the abbreviation for ElectroStatic Discharge Electrostatic discharge must be preceded by electro static charging Static electric charges generally occur whenever two bodies are rubbed against each other e g when walking shoe soles against the floor or driving a car tires against the street pavement The amount of the charge depends on several factors l e the charge is higher with a low air humid
25. osure values Sirona Dental Systems GmbH 13 3 HELIODENT Vario Operating Instructions SIDEXIS Intraoral HELIODENT Vario Possible exposure times epp ep e epep e e ep E Recommended exposure times with 8 SSD cone The recommended exposure times are limited to the fol and Sirona Full Size Universal X ray sensor lowing values from the number of possible exposure times pep Classification of the recommended exposure times according to tooth region Upper jaw Lower jaw Lower jaw Upper jaw canine lower Upper jaw anterior canine anterior jaw molars molars e i Children o NOTE Please check according to exposure region the time set ting on the digital time display of the unit before the expo sure When a 12 SSD cone and Sirona Full Size Universal X ray sensor is used the above exposure times are increased by 2 exposure levels Example 0 05 s gt 0 09 s or 0 11 s 0 17 s 60 87 816 D 3334 30 D 3334 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral HELIODENT MD Possible exposure times 13 Exposure values 13 4 HELIODENT MD peppers pepepeppepepopepeTopoT epe Recommended exposure times with 8 SSD cone and Sirona Full Size Universal X ray sensor Classification of the recommended exposure times according to tooth region Lower jaw anterior Lower jaw canine Upper jaw anterior IIT Adults mn Children 60 87 816 D 3334 D 3
26. rs stated in the rel evant documentation of the different Sirona intraoral X ray units therefore do not apply for the Sirona Full Size and Universal X ray sensors For other X ray sensors please use the exposure times from their operating instructions HELIODENT DS as from Serial No 15864 wall model and 4416 ceiling model Possible exposure times oppe e pee pe na nennae Recommended exposure times with 8 SSD cone and Sirona Full Size Universal X ray sensor 26 The recommended exposure times are limited to the fol lowing values from the number of possible exposure times pepper When the desired patient symbol is set to the tooth sym bol the recommended exposure times are assigned automatically Each tooth symbol is subdivided into three different exposure levels In the case of digital X ray exposures make sure to set the largest exposure level within a tooth symbol for X rays of adults and the smallest exposure level for X rays of children Only then does the associated value appear on the dig ital display Adjacent example Upper jaw molar Valid as from software version 17 number appears briefly after the unit is switched on 60 87 816 D 3334 D 3334 201 01 13 02 Sirona Dental Systems GmbH 13 Exposure values Operating Instructions SIDEXIS Intraoral 13 2 HELIODENT DS up to Serial No 15863 wall model and 4415 ceiling model Classification of the recommended exposure times
27. sensi tive to electrostatic discharge Even voltages which are imperceptible to the user can cause breakdown of the layers thus leading to a discharge current which melts the chip in the affected areas Damage to individual inte grated circuits may cause malfunction or failure of the system To prevent this from happening the ESD warning label next to the plug warns of this hazard 2 Technical data 1 3 Concerning the physics of electrostatic charges Technical data 1 General 2 Sensors 10 Original language of the present document Reg No China Product Standard No Cable length Degree of protection against electrical shock Physical pixel size Active area Outer dimensions Ambient temperature Storage temperature Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral The Digital Intraoral X ray system type D 3334 was tested by the VDE test and certification insti tute according to EN 60 601 1 1996 in conjunction with EN 60 601 1 1 9 1994 A1 1996 It fulfils the requirements specified therein Patent This product is covered by US Patent Numbers US 5 513 252 Additional patents are pending German SFDA lI 20052302655 YZB GEM 1866 2005 This product bears a CE marking documenting its compliance with the provisions of Council Di 98 42 EEC of June 14 1993 con cerning medical devices 3m Type BF 19 5 um pixel binning to 39 um 26 x
28. tically with preselection of Single exposure to ready for operation and with preselection of Multiple exposure to ready for exposure The preselection can be set in SIDEXIS NOTE In the case of disturbances of the data transfer to the PC the unit switches automatically to a safe mode enabling renewed transfer of the image to SIDEXIS In case of a lasting fault the image can be transferred to another PC by the service program SiRescue A CAUTION In this condition the acquisition unit must not be switched off to prevent the stored image from being deleted The green signal LED and the yellow signal LED of the corresponding sensor flash with increasing speed alter natingly For the operation of the SiRescue service program please read the corresponding software description in the SIDEXIS User Manual 19 10 Making the system ready for exposure 8 2 Switching the unit on Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral 1 0 Making the system ready for exposure d d SIDEXIS Demo Patient 01 11 1911 Patient Image Edit Analysis View Window Utilities 2 Single exposure Ctrl Shift l Multiple exposure Ctrl Shift M Status exposure Ctrl Shift S Intra y Panoramic X ray Yideo Video Start Stop Select Ctrl Shift P tT SAE Bommen Eiig Delete gt Save gt Close Gar fnt Despatch Send as E Mail
29. ting exposure data Sirona Dental Systems GmbH 11 1 Exposure control Operating Instructions SIDEXIS Intraoral Exposure control adapting exposure data Exposure control The radiation dose acquired by the X ray sensor as a result of the exposure data selected affects the image quality The X ray sensor accepts a wide exposure tolerance Thanks to automated image preprocessing the expo sures are displayed with optimized brightness and opti mized contrast Nevertheless a noisy unsharp image can result if the dose is too low This is in contrast to an excessive dose which results in overmodulation of the sensor and can thus cause dark fields in the image A CAUTION Image artifacts due to excessively low dose can be com pressed in part through subsequent image postprocess ing Image artifacts due to overmodulation of the sensor on the other hand cannot be compensated for Adapting exposure data HELIODENT DS You can switch over from conventional to digital expo sure technique by briefly pressing the D key The reduced exposure time for this is displayed The Digital indicator must light up For the HELIODENT DS exposure values see page 24 60 87 816 D 3334 22 D 3334 201 01 13 02 Sirona Dental Systems GmbH Operating Instructions SIDEXIS Intraoral 60 87 816 D 3334 D 3334 201 01 13 02 11 Exposure control adapting exposure data 11 2 Adapting exposure data