1.   The AirSim Advance Larynx has been designed to offer realism in the training  of microlaryngeal surgical and laser techniques  Evolving from Trucorp s  AirSim Advance Crico it has been uniquely designed to give optimal realism  while training in a theatre environment  The AirSim Advance Larynx comes  with disposable silicone vocal cord inserts for training in surgical techniques  for removing cancerous pathologies on the vocal cords  It also comes with  Trucorp   s new specially developed    TLT    material vocal cords which highlight  a range of cancers and polyps for the use of training in CO2 laser removal  techniques     These features combined with the    real feel    skin covering make the AirSim  Advance Larynx the most comprehensive and cost effective training tool  available for training and aspiring ENT surgeons     Each model will come with 3 silicone and 3 TLT vocal cord inserts as  standard  The AirSim Advance larynx is presented on a light and sturdy base  frame and is neatly packaged with it   s own black carrier case for ease of  transportation  There is also an option for an extra shelf piece which can be  retrofitted to the model to hold the laser apparatus     Contents  Included in the black carry case are the following items    1 x AirSim Advance Larynx Airway Management Manikin  1 x Blue Lung Bag with connector   1 x User manual CD   1 x Larynx cover   1 x Skin cover   1 x Consumable re order form    11    AirSim Baby       The AirSim Baby is the latest
2.  AirSim Multi can be used in the training of all the procedures facilitated by  the AirSim Standard with the addition of     e Naso tracheal intubation  e Awake fibreoptic examination  e Bag  amp  mask ventilation techniques     TruCorp recommend the following equipment sizes for optimal performance     e 7 0 7 5 mm ID for nasal intubation  e 8 0 9 0 mm ID for oral intubation  e Size 3 and 4 for LMA laryngeal masks   similar respective sizes for other supraglottic devices     The AirSim Bronchi  The AirSim Bronchi unit will provide a solution to your training needs in     e Diagnostic bronchoscopy    e Lung isolation techniques using left and right endobronchial tubes and  bronchial blockers    e Lung suctioning techniques    e For clinicians and industrial clients  the AirSim Bronchi is a leading  choice for demonstration of items such as    e Fibreoptic bronchoscopic equipment    e Single and double lumen tubes and bronchial blockers     27    e Specialised bronchial stents     The AirSim Bronchi can also be used in a similar manner to the AirSim Multi  and can cover an extensive range of training requirements     Trucorp recommend the following equipment sizes for optimal performance     e 7 0 7 5 mm ID for nasal intubation  e 8 0 9 0 mm ID for oral intubation  e Size 3 and 4 for LMA laryngeal masks   similar respective sizes for other supraglottic devices   e Size 35F   37F for endobronchial tubes     The AirSim Advance    The AirSim Advance can be used in the training of
3.  addition to the AirSim Family  Uniquely  constructed to allow realistic feedback during airway management procedures  and provides true  anatomically correct and visually accurate internal features     AirSim Baby has a realistic anatomy that enables basic and advanced  paediatric airway management  The AirSim Baby facilities training in the use  of bag mask ventilation  supraglottic airway insertion and both naso and  orotracheal intubation  In addition is can be used with all current video  laryngoscopes     Presented in a lightweight but sturdy frame  AirSim Baby comes shipped with  its own lungs to demonstrate correct tube placement and is neatly packaged  with its own lightweight case for easy transportation    Contents   Included in the black carry case are the following items     1 x AirSim Baby airway management manikin  2 x Blue Lung Bags with connectors    12    AirSim Pierre Robin     gt        The AirSim Pierre Robin is the next evolutionary addition to the TruCorp  Paediatric range  It was developed to highlight difficult airway management  techniques on infants with Pierre Robin Sequence  In line with Trucorp   s  current products this has been built with realistic anatomical features and our     real feel skin  The model allows for training in all aspects of infant airway  management including bag mask ventilation  both naso and orotracheal  intubation and difficult intubation techniques necessary for an infant with  mandibular hypoplasia     Features signific
4.  all the procedures  facilitated by the AirSim multi  which includes     e Naso tracheal intubation  e Awake fibreoptic examination  e Bag  amp  mask ventilation techniques     TruCorp recommend the following equipment sizes for optimal performance     e 7 0 7 5 mm ID for nasal intubation  e 8 0 9 0 mm ID for oral intubation  e Size 3 and 4 for LMA laryngeal masks   similar respective sizes for other supraglottic devices     The AirSim Advance Bronchi    The AirSim Advance Bronchi can be used in a similar manner to the AirSim  Advance and can cover an extensive range of training requirements including     e Naso tracheal intubation  e Awake fibreoptic examination  e Bag  amp  mask ventilation techniques     The AirSim Advance Bronchi unit will provide a solution to your training needs  in     e Diagnostic bronchoscopy    e Lung isolation techniques using left and right endobronchial tubes and  bronchial blockers    e Lung suctioning techniques    e For clinicians and industrial clients  the AirSim Bronchi is a leading  choice for demonstration of items such as     28    e Fibreoptic bronchoscopic equipment   e Single and double lumen tubes and bronchial blockers   e Specialised bronchial stents     TruCorp recommend the following equipment sizes for optimal performance     e 7 0 7 5 mm ID for nasal intubation  e 8 0 9 0 mm ID for oral intubation  e Size 3 and 4 for LMA laryngeal masks   similar respective sizes for other supraglottic devices   e Size 35F   37F for endobronchi
5.  lubricated     6  Ensure that all airway devices are prepared to the manufactures  recommendations and instructions  Before insertion of the device  generous amounts of lubricant should be used to cover the surfaces in  contact with the AirSim airway     7  Please ensure that the AirSim airway is cleaned after use  Please use  warm water of a dilute  8 10  w w  Sodium Bicarbonate solution until  all visible foreign matter and residue is removed     8  The head and neck skin of the models are made from durable and very  elastic polyurethane material  It can be cleaned using a lightly soaped   damp cloth  Please do not use and detergents or cleaning agents on  the skin material    9  Please replace the models unit back into the carrier case and  store in clean  dry conditions away from heat and light  avoid  contact with metals  solvents  oils or greases and strong detergents     16    Removing the AirSim Advance and AirSim Advance Bronchi  head from base    The head can be detached from the base by removing the 3 bolts from the  underside of the base as shown below        The head can be reattached to the base by attaching screws in positions 1  amp   2 before attaching 3     17    Quick set up guide for AirSim Advance Crico    10     11     Remove AirSim advance Crico from the black carrier case  with blue  bag and plastic connector     Connect one end of the plastic connector to the open section of the left  Bronchi on the AirSim airway     Connect the other end of the plas
6.  respective sizes for other supraglottic devices   e Size 1 for video laryngoscopes    The AirSim Child    The AirSim Child can be used in the training of all the procedures facilitated  by child airway management  which includes     Naso tracheal intubation   Positive pressure ventilation    Bag  amp  mask ventilation techniques   Endotracheal intubations     TruCorp recommend the following equipment sizes for optimal performance     e Size 5 5   6 oro tracheal tubes  size 4 5   5 0 naso tracheal tubes  e Size 2 for LMA laryngeal masks    similar respective sizes for other supraglottic devices   e Size 2 for video laryngoscopes    Needle Access    The AirSim product range for the AirSim Standard  Multi and Bronchi can be  readily used for training in Needle Cricothyroidotomy     For needle Cricothyroidotomy we supply the airway with a pinhole that has  been precut in the correct anatomical area  The material which the airway is  constructed from has unique properties in that when dilated from pinhole size  it accommodates the size of the dilation tool and thus gives an airtight seal  around the instrument whether this is a needle or a dilator     The pin hole is positioned in the correct anatomical area and is covered with a  specialized and replaceable tape  The trainee has to identify the pinhole by    31    palpation and then insert the needle and or the dilators  When the needle or  dilators are removed the material reverts to its original size  We also supply  spare sea
7.  which  includes     Full range of supraglottic devices  Laryngoscopes   Tracheal Tubes   Fibreoptic Laryngoscopes  Needle Surgical Cricothryoidotomy  Naso tracheal intubation   Awake Fibreoptic examination   Bag  amp  mask ventilation techniques     TruCorp recommend the following equipment sizes for optimal performance     e 7 0 7 5 mm ID for nasal intubation  e 8 0 9 0 mm ID for oral intubation  e Size 3 and 4 for LMA laryngeal masks   similar respective sizes for other supraglottic devices     The AirSim Baby    The AirSim Baby can be used in the training of all the procedures facilitated  by infant airway management  which includes     Naso tracheal intubation   Positive pressure ventilation    Bag  amp  mask ventilation techniques   Endotracheal intubations     TruCorp recommend the following equipment sizes for optimal performance   e Size 3 5   4 tracheal tubes  e Size 1 for LMA laryngeal masks   similar respective sizes for other supraglottic devices   e Size 1 for video laryngoscopes    30    The AirSim Pierre Robin    The AirSim Pierre Robin can be used in the training of all the procedures  facilitated by a difficult infant with congenital defects for airway management   which includes     Naso tracheal intubation   Positive pressure ventilation    Bag  amp  mask ventilation techniques   Endotracheal intubations     TruCorp recommend the following equipment sizes for optimal performance     e Size 3 5   4 tracheal tubes  e Size 1 for LMA laryngeal masks    similar
8. agement manikin   1 x Blue Lung Bag with connector   1 x Foam Block  for securing the head in a neutral position during storage   1 x User manual CD    AirSim Bronchi       The AirSim Bronchi is the latest product addition to the AirSim family   providing anatomically correct detail down to the fourth generation bronchi     The AirSim Bronchi provides exceptional detail in both internal and external  features  made possible through a combination of cutting edge moulding  technology and carefully handcrafted processes     Contents  Included in the black carry case are the following items  1 x AirSim Bronchi airway management manikin    1 x Foam Block  for securing the head in a neutral position during storage   1 x User manual CD    AirSim Advance       The AirSim Advance is the most recent addition to the AirSim family  The  advance model still maintains the features of the AirSim Multi unit  however  for added realism a head and neck skin has been added  It is lightweight and  portability  and maintains the unique features such as the AirSim airway and  nasal passage     Contents  Included in the black carry case are the following items  1 x AirSim Advance Airway Management Manikin    1 x Blue Lung Bag with connector  1 x User manual CD    AirSim Advance Bronchi       The AirSim Advance Bronchi is the next generation to the AirSim family   providing anatomically correct detail down to the fourth generation bronchi  together with the addition of our    real feel    skin cover
9. al tubes     The AirSim Advance Crico    In addition to Needle Surgical Cricothryoidotomy the AirSim Advance Crico is  also ideal for training in     Full range of supraglottic devices  Laryngoscopes   Tracheal Tubes   Fibreoptic Laryngoscopes  Naso tracheal intubation   Awake Fibreoptic examination   Bag  amp  mask ventilation techniques     TruCorp recommend the following equipment sizes for optimal performance     e 7 0 7 5 mm ID for nasal intubation  e 8 0 9 0 mm ID for oral intubation  e Size 3 and 4 for LMA laryngeal masks   similar respective sizes for other supraglottic devices     The AirSim Advance Traci    In addition to percutaneous Tracheostomy the AirSim Advance Traci is also  ideal for training in     Full range of supraglottic devices  Laryngoscopes   Tracheal Tubes   Fibreoptic Laryngoscopes  Naso tracheal intubation   Awake Fibreoptic examination   Bag  amp  mask ventilation techniques     TruCorp recommend the following equipment sizes for optimal performance     29    e 7 0 7 5 mm ID for nasal intubation  e 8 0 9 0 mm ID for oral intubation  e Size 3 and 4 for LMA laryngeal masks   similar respective sizes for other supraglottic devices     The AirSim Advance Larynx    The AirSim Advance Larynx can be used in the training of all laser techniques  for removing cancerous pathologies on the vocal cords using a Co  laser   Applicable Co  laser companies are to be used for this application     On top of this the model can still be used to facilitate procedures 
10. ant mandibular hypoplasia  glossoptosis  cleft palate and a  bifid uvula  It is an anatomically correct model with very realistic features to  allow for high fidelity training of difficult airway management     True to Trucorp   s well known branding the model is presented on a lightweight  and sturdy frame     The model comes shipped with its own lungs to demonstrate correct tube  placement  It is neatly packaged in its own lightweight case for easy  transportation     Recommended sizes of tracheal tubes are 3 5 4 0 and recommended  supraglottic airway is size 1    Contents    Included in the black carry case are the following items     1 x AirSim Pierre Robin airway management manikin  2 x Blue Lung Bags with connectors    13    AirSim Child       AirSim Child is the latest addition to the AirSim Paediatric range of advanced  airway models  This anatomically correct six year old child manikin has both  realistic size and anatomical features perfect for practicing paediatric airway  management skills  including bag mask ventilation  supraglottic airway  insertion  naso and orotracheal intubation     The AirSim Child model allows for training in all aspects of infant airway  management  including insertion of Laryngeal masks and endotracheal  intubation both nasal and oral     Realistic and true internal anatomical features allow for an efficient and  successful demonstration of all paediatric videolaryngoscopes     True to Trucorp   s products this model is presented in an a
11. cal procedure     19    Quick set up guide for AirSim Advance Traci    10     11     Remove AirSim Advance Traci from the black carrier case  with blue  bag and plastic connector     Connect one end of the plastic connector to the open section of the left  Bronchi on the AirSim airway     Connect the other end of the plastic connector to the blue lung bag     Ensure that the tongue is inflated with approx 20ml of air  This will  create normal lingual tension  Increasing the amount of air will create  a more difficult airway management scenario     Each model shipped will be able to begin the tracheostomy procedure  immediately but please ensure that the airway has sealing tape  covering the Traci hole located between the 2    and 3    Tracheal ring   the larynx is in its secured resting position and that the skin is attached  to all the velcro points to enable a fully functioning product     After a nominal amount of procedures ensure that the airway sealing  tape is replaced as this will affect the airtight quality of the product     The larynx can be removed easily and another piece of sealing tape cut  to approx 5 6cm and attached over the Traci hole in the airway  Please  ensure that the airway is clean and dry before attaching the tape to  ensure secure tape adhesion     To ensure the larynx is in it   s secure and correct resting position line up  the gap on the larynx that resembles the 2   and 3  tracheal ring and  line up with white sealing tape     Each replaceable 
12. d       The AirSim Standard is uniquely constructed to allow realistic feedback during  airway management procedures and provides true  anatomically correct and  visually accurate internal features     The neck construction allows the head to be moved and secured in a number  of positions  This ranges from the standard    sniffing    position to more difficult  scenarios     The AirSim Standard also features an inflatable tongue with real life size and  texture  There is also an option to include    breakout    teeth to simulate the  effects of bad practice in laryngoscopy     Contents   Included in the black carry case are the following items  1 x AirSim Standard airway management manikin   1 x Blue Lung Bag with connector    1 x Foam Block  for securing the head in a neutral position during storage   1 x User manual CD    AirSim Multi       The AirSim Multi contains the key features of the AirSim Standard with the  addition of a nasal passage and a chin     The AirSim Multi facilitates training on nasal procedures as well as bag and  mask ventilation techniques     The nasal passage has been developed in a manner similar to the main  airway  This gives the same anatomical realism and functionality  important  landmarks such as the turbinates are clearly defined  In addition the material  used offers the same tactile feedback which is delivered with the main airway  itself     Contents    Included in the black carry case are the following items    1 x AirSim Multi airway man
13. e lubricant ensure that the internal airway is well  lubricated including the tongue  hard palate  back of the mouth and  epiglottis  If appropriate ensure that the nasal passage is lubricated     Ensure that all airway devices are prepared to the manufactures  recommendations and instructions  Before insertion of the device  generous amounts of lubricant should be used to cover the surfaces in  contact with the AirSim airway     Please ensure that the AirSim airway is cleaned after use  Please use  warm water of a dilute  8 10  w w  Sodium Bicarbonate solution until  all visible foreign matter and residue is removed     Please replace the AirSim unit back into the carrier case and store in    clean  dry conditions away from heat and light  avoid contact with  metals  solvents  oils or greases and strong detergents     15    Quick set up guide for AirSim Advance and AirSim Advance  Bronchi    1  Remove models from the black carrier case  with blue bag and  plastic connector     2  Connect one end of the plastic connector to the open section of the left  Bronchi on AirSim airway   If applicable     3  Connect the other end of the plastic connector to the blue lung bag    If applicable     4  Ensure that the tongue is inflated with approx 20ml of air  This will  create normal lingual tension  Increasing the amount of air will create  amore difficult airway management scenario     5  Using Trucorp   s silicone lubricant ensure that the internal airway and  Nasal passage are well
14. esthetically pleasing  lightweight frame with lung bags included to illustrate correct tube placement   This model also comes with a lightweight carrier case as standard for ease of  transport     Contents    Included in the black carry case are the following items     1 x AirSim Child airway management manikin  2 x Blue Lung Bags with connectors    PLEASE NOTE THAT MOUTH TO MOUTH RESUSCITATION TRAINING IS  NOT RECOMMENDED ON THESE MODELS AS THE AIRWAY AND  LUNGS ARE NOT DISPOSABLE OR REPLACEABLE     14    Quick set up guide for AirSim Standard  Multi and Bronchi    1     Remove the AirSim unit from the black carrier case  with blue bag and  plastic connector  if applicable      Connect one end of the plastic connector to the open section of the left  Bronchi on AirSim airway  if applicable     Connect the other end of the plastic connector to the blue lung bag  if  applicable     Ensure that the tongue is inflated with approx 20ml of air  This will  create normal lingual tension  Increasing the amount of air will create  a more difficult airway management scenario     The neck can be adjusted and locked using the    Wing nut    tensioner   Using this neck lock system  the head can be accurately placed in the     sniffing the morning air position  This is achieved when the head is  moved so that the red marks on the fixed neck joint are in alignment   For more difficult airway management scenarios the head can be fixed  in a more forward position     Using Trucorp   s silicon
15. he additional palpable thyroid cartilage  cricothryoid membrane  and cricoid cartilage     Contents    Included in the black carry case are the following items    1 x AirSim Advance Crico Airway Management Manikin   1 x Blue Lung Bag with connector   1 x User manual CD   1 x Roll of airway sealing tape   1 x Strip of replaceable neck skin onto model as supplied  1 x Consumable re order form    AirSim Advance Traci       The AirSim Advance Traci is an innovative addition to the AirSim family  The  Advance Traci model has the added benefit of a new design that allows for  greater realism  It has anatomically correct laryngeal cartilages and palpable  tracheal rings to provide positive user feedback  The Larynx has been  manipulated to contain the anatomical features which are highlighted during a  Percutaneous tracheostomy procedure  It is anatomically correct with a  replaceable neck skin which can last up to 25 times and a representative  larynx  It is lightweight and portable  and maintains the unique features such  as the AirSim airway and nasal passage together with the additional palpable  thyroid cartilage and cricoid cartilage     Contents  Included in the black carry case are the following items    1 x AirSim Advance Traci Airway Management Manikin   1 x Blue Lung Bag with connector   1 x User manual CD   1 x Roll of airway sealing tape   1 x Strip of replaceable neck skin attached onto model as supplied  1 x Consumable re order form    10    AirSim Advance Larynx     
16. he bronchi    Using Trucorp s silicone lubricant ensure that the internal airway and  Nasal passage are well lubricated     Ensure that all airway devices are prepared to the manufactures  recommendations and instructions  Before insertion of the device  generous amounts of lubricant should be used to cover the surfaces in  contact with the AirSim airway     Please ensure that the AirSim Child airway is cleaned after use   Please use warm water of a dilute  8 10  w w  Sodium Bicarbonate  solution until all visible foreign matter and residue is removed     The head and neck skin of the AirSim Child is made from durable and  very elastic polyurethane material  It can be cleaned using a lightly  soaped  damp cloth  Please do not use and detergents or cleaning  agents on the skin material     Please replace the AirSim Child unit back into the carrier case and    store in clean  dry conditions away from heat and light  avoid  contact with metals  solvents  oils or greases and strong detergents    26    Airway Management  The AirSim Standard  The AirSim Standard is ideal for training in the use of     Laryngeal Masks   Full range of supraglottic devices  Laryngoscopes   Tracheal Tubes   Fibreoptic Laryngoscopes   Needle Cricothyroidotomy Systems    TruCorp recommend the following equipment sizes for optimal performance     e 8 0 9 0 mm ID for oral intubation  e Size 3 and 4 for LMA laryngeal masks   similar respective sizes for other supraglottic devices     The AirSim Multi    The
17. he manufactures    18    recommendations and instructions  Before insertion of the device  generous amounts of lubricant should be used to cover the surfaces in  contact with the AirSim airway and Cricothryoid membrane     Please ensure that the AirSim airway is cleaned after use  Please use  warm water of a dilute  8 10  w w  Sodium Bicarbonate solution until  all visible foreign matter and residue is removed     The head and neck skin of the AirSim Advance is made from durable  and very elastic polyurethane material  It can be cleaned using a  lightly soaped  damp cloth  Please do not use and detergents or  cleaning agents on the skin material    Please replace the AirSim Advance Crico unit back into the carrier  case and store in clean  dry conditions away from heat and light  avoid  contact with metals  solvents  oils or greases and strong detergents    Trucorp provide the following spare parts for the AirSim Advance Crico  These  can be ordered while purchasing using the following codes     LA1000   1 x Larynx     Anatomical Larynx containing the Thyroid Cartilage   Cricothryoid membrane and Cricothryoid cartilage     RS1005     Overlay neck skin attachments   older model  Sold in packs of    five     RSN1005   Wrap around neck skin attachments     Sold in packs of five     ST1000   1 x Sealing tape   Sealing tape used to replicate the Cricothryoid  membrane  This interchangeable part is used to cover the cricothryoid hole in  the airway and is replaced after every surgi
18. ightly soaped  damp  cloth  Please do not use and detergents or cleaning agents on the skin  material     Please DO NOT USE any of the following when cleaning the  AirSim product range    e Germicides  disinfectants  or chemical agents such as  glutaraldehyde  e g  Cidex        e Ethylene oxide  phenol based cleaners or _ iodine containing  cleaners    Such substances are absorbed by the AirSim materials  resulting in exposure  of the user to unnecessary risk and possible deterioration of the device     32    Do not use a device that has been exposed to any of these substances     NB  IT IS IMPORTANT THAT GENEROUS AMOUNTS OF TRUCORP  LUBRICANT IS USED DURING AIRWAY AND DEVICE INTERVENTIONS     Warranty    TruCorp warrants this unit to be free of defects in materials and workmanship  and to give satisfactory service for a period of 1 year from the date of  purchase  The TruCorp warranty can now provide an additional 2  or 3   year warranty onto the products which will ensure full model repairs and  returns and any other issues with the model at an extra premium price  Please  contact sales for more details     This ensures that our customers receive maximum coverage on each product   If the unit should malfunction it must be returned to the factory for evaluation   Upon examination by TruCorp  if the unit is found to be defective it will be  repaired or replaced at no charge  However this warranty is VOID  if the unit  shows evidence of having been tampered with or shows evide
19. ing  This model combines  together the skin covering of the AirSim Advance with all the combined  features of the AirSim Bronchi to provide a true  anatomically correct and  visually accurate Bronchi trainer  The AirSim Advance Bronchi features an  improved neck design allowing for accurate articulation and provides  exceptional detail in both internal and external features    Contents    Included in the black carry case are the following items    1 x AirSim Advance Bronchi Airway Management Manikin  1 x User Manual CD    Please note  bag mask ventilation cannot be achieved on this model due to the  closed cell Bronchi features  Additional lung bags can be attached onto the  bronchioles to highlight successful bag mask ventilation but please ask your  distributor representative or Trucorp for this feature if applicable as this is not a  product feature that comes as standard with the Bronchi range of models     AirSim Advance Crico       The AirSim Advance Crico is the newest addition to the AirSim family  The  Advance Crico model still maintains the features of the AirSim Advance unit   however for added realism during needle surgical Cricothyroidotomy the neck  area has been manipulated to contain the anatomical features which are  highlighted during a Cricothyroidotomy procedure  It is anatomically correct  with a replaceable neck skin and larynx  It is lightweight and portable  and  maintains the unique features such as the AirSim airway and nasal passage  together with t
20. ling tape for further use     Please note that the use of a scalpel or any sharp blade prior to  performing Cricothyroidotomy on the AirSim Standard  Multi or Bronchi  is NOT required  Doing so may damage the airway material in the area of  the preformed pinhole and will invalidate the warranty  The use of a  scalpel CAN be used on the AirSim Advance Crico model     Care and maintenance  Cleaning and Storage    Store in clean  dry conditions away from heat and direct sunlight  avoid  contact with metals  solvents  oils or greases and strong detergents     Thoroughly wash the AirSim airway in warm water  using a dilute  8 10  w w   sodium bicarbonate solution until all visible foreign matter is removed     Mild detergents or enzymatic cleaning agents may be used on the airway in  accordance with the manufacturer s instructions and at the proper dilution   The detergent must not contain skin or mucous membrane irritants     Clean the device using a small soft bristle brush  approximately 1   2 inch or  12 5mm in diameter   Gently insert the brush through the airway  taking care  not to damage the material  Extra care must be taken when cleaning around  the vocal cords     Thoroughly rinse the airway in warm flowing tap water to remove cleaning  residues  Carefully inspect the device to ensure that all visible foreign matter  has been removed     The head and neck skin of the AirSim Advance is made from durable and very  elastic polyurethane material  It can be cleaned using a l
21. nce of having  been damaged by excessive heat  the use of sharp instruments   misapplication  misuse or other operating conditions outside of TruCorp   s  control  Components which wear or are damaged by misuse are not  warranted and will charged if repair has been approved     Before returning any models please contact TruCorp  To avoid delays please  ensure the following information is available    1  Returnee   s name  address and phone number    2  Model and serial numbers   3  Repair instructions with potential issues  with images if possible   4  Apparatus devices and number of uses on the model    Please direct all warranty and repair requests inquires to    TruCorp Ltd   The Mount Business Park  2 Woodstock Link   Belfast  BT6 8DD  Northern Ireland    Tel   44  0 28 9073 7281  Fax   44  0 28 9073 7282    Email  info trucorp co uk and or rcolhoun trucorp co uk    Every precaution for accuracy has been taken in the preparation of this manual  however  TruCorp  neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any  damages that result from the use of the product in accordance with the information contained in the  manual     33    
22. neck skin can be easily removed and a new piece  attached  To ensure a completed fully functional neck skin  all velcro  locations must be attached to the skin     Using Trucorp   s silicone lubricant ensure that the internal airway and  the nasal passage is well lubricated     Ensure that all airway devices are prepared to the manufactures  recommendations and instructions  Before insertion of the device  generous amounts of lubricant should be used to cover the surfaces in    20    contact with the AirSim airway and the Tracheal rings     12  Please ensure that the AirSim airway is cleaned after use  Please use  warm water of a dilute  8 10  w w  Sodium Bicarbonate solution until  all visible foreign matter and residue is removed     13  The head and neck skin of the AirSim Advance Traci is made from  durable and very elastic polyurethane material  It can be cleaned using  a lightly soaped  damp cloth  Please do not use and detergents or  cleaning agents on the skin material    14  Please replace the AirSim Advance Traci unit back into the carrier case  and store in clean  dry conditions away from heat and light  avoid  contact with metals  solvents  oils or greases and strong detergents    Trucorp provide the following spare parts for the AirSim Advance Traci  These  can be ordered while purchasing using the following codes     TT1000   1 x Larynx     Anatomical Larynx containing the Thyroid Cartilage  and tracheal rings     RSN1005     Wrap around neck skin attachments  S
23. old in packs of 5  ST1000   1 x Sealing tape   Sealing tape used to replicate the Tracheal ring  membrane  This interchangeable part is used to cover the space between the    2  and 3  tracheal ring hole in the airway and is replaced after every surgical  procedure     21    Quick set up guide for AirSim Advance Larynx    1     Remove AirSim Advance Larynx from the black carrier case  with blue  bag and plastic connector       Connect one end of the plastic connector to the open section of the left    Bronchi on AirSim airway if you carrying out airway management on  the model   If applicable       Connect the other end of the plastic connector to the blue lung bag       Ensure that the tongue is inflated with approx 20ml of air  This will    create normal lingual tension  Increasing the amount of air will create a  more difficult airway management scenario       Each model shipped will be able to begin usage immediately with the    addition of the appropriate vocal cord insert but please ensure that the  larynx is in its secured resting position  and that the skin is attached to  all the Velcro points to enable a fully functioning product     Ensure that the shelf accompanied with the model is secured and  positioned correctly so that it is facing away from the head so that the  laser securing apparatus can be mounted  Also please ensure the  screw nut is secured and in place       When choosing on the appropriate vocal cord insert please ensure that    if a laser is being u
24. on point lines up with the  location hole in the larynx  Re attach the larynx cover and secure the  neck skin into please at all the Velcro locations     11  Full care is needed when using the laser on the model and that only  the vocal cord area with the TLT material is used for ablation     12  Using Trucorp s silicone lubricant ensure that the internal airway and  Nasal passage is well lubricated if used for airway management   lf  applicable     13 Ensure that all airway devices are prepared to the manufactures  recommendations and instructions  Before insertion of the device  generous amounts of lubricant should be used to cover the surfaces in  contact with the AirSim airway     14 Please ensure that the AirSim airway is cleaned after use  Please use  warm water of a dilute  8 10  w w  Sodium Bicarbonate solution until  all visible foreign matter and residue is removed     15 The head and neck skin of the AirSim Advance Larynx is made from  durable and very elastic polyurethane material  It can be cleaned using  a lightly soaped  damp cloth  Please do not use and detergents or  cleaning agents on the skin material    16 Please replace the AirSim Advance Larynx unit back into the carrier  case and store in clean  dry conditions away from heat and light  avoid  contact with metals  solvents  oils or greases and storing detergents    23    Trucorp provide the following vocal cord inserts and parts for the AirSim  Advance Larynx  These can be ordered while purchasing using 
25. rata       ey    S         User Manual    AirSim    Version 4 1    tru    coro    Table of Contents    AIRSIM RANGE  Introduction    Introducing the AirSim range   Quick set up guides   AirSim Standard  Multi  amp  Bronchi   AirSim Advance   AirSim Advance Bronchi   AirSim Advance Crico   AirSim Advance Traci   AirSim Advance Larynx   AirSim Baby   AirSim Pierre Robin    AirSim Child    Airway management    Care and maintenance    Warranty    15  16  16  18  20  22  25  25  26    27    32    33    Introduction    Designed and produced by TruCorp  the AirSim range brings highly realistic  and fully functional airway training systems to the market     The main and most important component of the AirSim range is the unique  AirSim airway  This is a faithful reproduction of the human airway anatomy  and as such is invaluable as a training aid to facilitate the learning and  development of airway management skills for all health professionals     The innovated development and manufacture approach used makes the  AirSim airway unique  The main features of the AirSim Airway which makes it  unique include     e The airway is moulded from a master which was created from data  collected from a CT scan of a person    e The one piece mould together with the sophisticated dipping procedure  during manufacture makes possible much of the realism offered    e Integrated one piece and seamless construction for real life  functionality     Introducing the AirSim product range    AirSim Standar
26. re     24    Quick Set up Guide for AirSim Baby  amp  AirSim Pierre Robin    1  Remove the AirSim Baby and AirSim Pierre Robin from the black  carrier case  with blue lung bag    2  Connect both ends of the lung bags to the open sections of the bronchi    3  Using Trucorp s silicone lubricant ensure that the internal airway and  Nasal passages are well lubricated     4  Ensure that all airway devices are prepared to the manufactures  recommendations and instructions  Before insertion of the device  generous amounts of lubricant should be used to cover the surfaces in  contact with the AirSim airway     5  Please ensure that the AirSim Baby and Pierre Robin airway is cleaned  after use  Please use warm water of a dilute  8 10  w w  Sodium  Bicarbonate solution until all visible foreign matter and residue is  removed     6  The head and neck skin of the AirSim Baby and Pierre Robin is made  from durable and very elastic polyurethane material  It can be cleaned  using a lightly soaped  damp cloth  Please do not use and detergents  or cleaning agents on the skin material     T  Please replace the AirSim Baby and Pierre Robin unit back into the  carrier case and store in clean  dry conditions away from heat and light   avoid contact with metals  solvents  oils or greases and strong  detergents    25    Quick set up guide For AirSim Child    1     Remove the AirSim Child from the black carrier case  with blue lung  bag    Connect both ends of the lung bags to the open sections of t
27. sed for laser techniques that only to use the TLT  material serial codes     LVC  This material has been tested to not give  out toxic fumes upon Co  laser ablation and is safe to use  Using a CO   laser on the silicone surgical inserts will be potentially harmful and your  warranty will be affected and you will not be viable for replacements     When choosing the vocal cord for surgical techniques please use the  silicone vocal cord inserts with serial codes   SVC as these are  specifically designed for surgical procedures only and NOT laser  techniques     When ordering the vocal cord inserts please ask for guidance upon  your intended purpose and we can guide you on the best inserts for  your application  We do advise that the inserts are only ordered as and  when for demand purposes and not ordered to build up stock as the  shelf life is short on the laser inserts     22    9  When the TLT material for laser techniques is not being used or is not  needed please ensure that is it kept in the air tight container  The  material can dry out rapidly if not stored correctly  We also advise not  ordering delivering the vocal cord inserts until a day or two before  you re intended purpose based on this fact  Your warranty will be  affected if the TLT inserts have found to be stored incorrectly     10 To insert the vocal cords peel back the neck skin  remove the larynx  cover and in the space provided in the larynx place the appropriate  vocal cords  Ensuring that the lower locati
28. the following  codes     For laser procedures   LVC C1  Cancer 1     Single small cancer on vocal cords  LVC P2  Polyp 2   Two small polyps opposing on the vocal cords    LVC C2     Cancer 2     One single large Tumour    For Surgical procedures    SVC C1   Cancer 1     Single small cancer on vocal cords  SVC P2   Polyp 2   Two small polyps opposing on the vocal cords    SVC C2   Cancer 2     One single large Tumour    LAR200   Larynx cover  LS1005   LS1010   Overlaying skin in packs of 5 or 10    Disclaimer  The AirSim Advance Larynx has materials that with  misuse or misdirection of a laser can cause very damaging effects  to the model and destroy the outer silicone facial skin and the  internal latex airway  Also there is a high risk chance of fire  damage to the models when exposing the laser to the areas  mentioned above  other than on the vocal cord inserts  The vocal  cord inserts should be the only area that is in direct contact with  the laser  Misuse or application of the laser at any other location  on the model other than the designated TLT vocal cord insert will  result in warranty being void  The laser should only be used for the  TLT vocal cord inserts and not the silicone vocal cords inserts   Again this would make the warranty void     Adequate ventilation is required when using the model in a theatre  environment when ablating the TLT inserts with a CO    laser  The  potential gases released have not been fully characterised and  please ensure minimal exposu
29. tic connector to the blue lung bag     Ensure that the tongue is inflated with approx 20ml of air  This will  create normal lingual tension  Increasing the amount of air will create  a more difficult airway management scenario     Each model shipped will be able to begin Cricothyroidotomy procedure  immediately but please ensure that the airway has sealing tape  covering the Cric hole  the larynx is in its secured resting position and  that the skin is attached to all the velcro points to enable a fully  functioning product     After a nominal amount of procedures ensure that the airway sealing  tape is replaced as this will affect the airtight quality of the product     The larynx can be removed easily and another piece of sealing tape  cut to approx 5 6cm and attached over the Cric hole in the airway   Please ensure that the airway is clean and dry before attaching the  tape to ensure secure tape adhesion     To ensure the larynx is in it   s secure resting position line up the gap on  the larynx that resembles the cricothryoid membrane to the white  sealing tape     Each replaceable neck skin can be easily removed and a new piece  attached and we hope that it will last up to 25 times before needing  replaced  To ensure a completed fully functional neck skin  all velcro  locations must be attached to the skin     Using Trucorp   s silicone lubricant ensure that the internal airway and  the nasal passage is well lubricated     Ensure that all airway devices are prepared to t
    
Download Pdf Manuals
 
 
    