Home
        Ladder Program Converter Operation Manual
         Contents
1.                                                                                           Instruction z Convert  No   S7 200  Class Function Static Remark  125   INCB Math Instructions Bit Increment O  126   DECB Math Instructions Bit Decrement O  127   INCW Math Instructions Word Increment O  128   DECW Math Instructions Word Decrement O  129   INCD Math Instructions Double Word Increment O  130   DECD Math Instructions Double Word Decrement O  131   ADD_R Real Math Instructions   Add Real IN1 OUT OUT O  132   SUB_R Real Math Instructions   Subtract Real IN1 OUT OUT     133   MUL_R Real Math Instructions   Multiply Real IN1 OUT OUT O  134  DIV_R Real Math Instructions   Divide Real IN1 OUT OUT     135   SQRT Real Math Instructions   Square Root x  136  LN Real Math Instructions   Natural Logarithm x  137   EXP Real Math Instructions   Natural Exponential x  138   SIN Real Math Instructions   Sine x  139   cos Real Math Instructions   Cosine x  140   TAN Real Math Instructions   Tangent x  141 PID Real Math Instructions   PID Loop x  142   MOV B Move Instructions Move Byte O  143   MOV_W Move Instructions Move Word O  144   MOV_DW Move Instructions Move Double Word O  145   MOV_R Move Instructions Move Real O  146   BLKMOV_B   Move Instructions Block Move Byte x  147 A IC Move Instructions Block Move Word O  148   BLKMOV_D   Move Instructions Block Move Double Word O  149   SWAP Move Instructions Conversion Byet O  150   MOV_BIR Move Instructions Move Byte Immediate Read x  1
2.                                                                                         Instruction    Convert  No   S7 200  Class Function Status Remark  195  DI_S Conversion Double Integer to String x  Instructions  196   RS Conversion Real to String O  mi Instructions  197 Is   Conversion String to Integer x    Instructions  198  s_DI Conversion String to Double Integer x    Instructions  199  SR Conversion String to Real O  Instructions  Program Control  200   JMP   Jump to Label O  Instructions  201   LBL Program ontra Label O  Instructions  Program Control     202  SBR   Subroutine Start O  Instructions  203 CRET Program Control Condutional Return from x   Instructions Subroutine  204   FOR Program Gontro For Next Loop O  Instructions  Program Control  205   NEXT   For Next Loop O  Instructions  Program Control  206   SCR Load SCR O  Instructions  207  SCRT Program  control SCR Transition O  Instructions  208   CSCRE Program control Conditional SCR End x  Instructions  Program Control  209   SCRE   SCR End x  Instructions  Program Control    210  CALL   Call Subroutine O  Instructions       Control FOR NEXT loop number  211   FINAL gran  Included in FOR when O  Instructions  converted   212 END Program Control END x  Instructions  213 DIAG  LED    Program Control Diagnostic LED x  Instructions  214 STOP Program Control Stop y  Instructions  215   WDR Program  Control Watchdot Reset  300ms  x  Instructions  216   LPS Logic Stack Logic Push O  Instructions  217   LRD Logi
3.                                                       5 Fx   Fx   Fx   Fx   Convert  No  Instruction Function Class 3 2 AN   4S Status Remark  367   TRDP Read RTC data Real Time clock e e e e x  Control  368   TWR Set RTC data Real Time clock e e e e x  Control  369   TWRP Set RTC data Real Time clock e e e e x  Control  370   DHOUR Hour meter Real Time clock e e e e x  Control  371   HOUR Hour meter Real Time clock e e e e x  Control  372   GRY Decimal to Gray Gray Codes 919     Code  373   GRYP Decimal to Gray Gray Codes 919     Code  374   DGRY Decimal to Gray Gray Codes 919     Code  375   DGRYP Decimal to Gray Gray Codes 919     Code  376   GBIN Gray Code to Gray Codes e eoe x  Decimal  377   GBINP Gray Code to Gray Codes 919     Decimal  378   DGBIN Gray Code to Gray Codes 919     Decimal  379   DGBINP Gray Code to Gray Codes 919     Decimal  380   RD3A Read form External Device e e e x  Dedicated Analog  Block  381   RD3AP Read form External Device e e e x  Dedicated Analog  Block  382   WR3A Write to Dedicated External Device e e e x  Analog Block  383   WR3AP Write to Dedicated External Device e e e x  Analog Block  384   EXTR External ROM Extension Function e e x  Function  385   EXTRP External ROM Extension Function e e x  Function  386   DEXTR External ROM Extension Function e e x  Function  387   DEXTRP External ROM Extension Function e e x  Function  388   COMRD Read Device Others e x  Comment Data  389   COMRDP Read Device Others e x  Comment Data  390   RND Ra
4.                      V Generate a conversion list    File path of the conversion list       Browse         Fig  5 14 Ladder Conversion Dialogue box    21 54    Ladder Program Converter Operation Manual     7  Click the Browse Button  Designate the name and path of conversion list file     Save in   5  My Documents          ck E3   my Music     a My Pictures             Save as type   Converting list file    csv     Cancel         Fig 5 15 conversion list file selection Dialogue box     8  Select the conversion destination PLC type  Click the OK Button and the Converting progress bar will be  displayed              Fig  5 16 Converting Progress Bar    22154    Ladder Program Converter Operation Manual     9  The converted program will be displayed in the CK Programmer  Corresponding converter information  will display in the output window If the conversion list file designated in step 6  the conversion results will  be output to this file                       7  new     CK Programmer      HewPLC1 HewProgrami Sectioni  Diagram     5 Fite Edit View Insert Program PLC Simulation Tools Window Help   x  Dee       SR BS Bos             r   2      11 1    n  m          mm             Bp Ae B EB EDGE  29  4  ARE Ha    889  EB    d PP             gt         d    NewProject     fa NewPLC1 CP1E  Offline    Symbols  D Network Gonnent  Settings 1  0 00 0  190 00  iy uh    e Memory    Programs         gi NewProgrami  00  NOV  021  Nove     symbols      Source word  TENP_CH_01 This is a ten
5.              mn      4  En             ym  TEMP         Data Bl    E System   PROGRAM COMMENTS    58 9 Cross F Network 1  EB Commu    Wizard    E e Tools  B Instructions       Favorite    Bit Logi  5   58 Clock     6  Compar Network 2    Conver  1 1  Counte v    I   Tr Tr ma  n A SBROAINTO   11                     Network 2 Ln 1  Col 1    Fig  5 12 Siemens Instruction  Mnemonic  list View   4  Select the program needed to be converted     Note  It has to start from Network1  and the minimum copy unit is one Network     20154    Ladder Program Converter Operation Manual     5  Start up CX Programmer and create a new project               new     CX Programmer      NewPLCI NewPrograml Sectionl  Diagram          File Edit View Insert Program PLC Simulation Tools Window Help  Deh             BR A           CM  m M RI Ee      SD  E  S  22 39 8    xl    NewProject     NewPLC1 CP1E  Offline    gt  Symbols   5  Settings          Memory    A Programs      Sg  NewProgranl  00       Symbols    373         Sectionl         Em    Project      For Help  press Fi NewPLC1  Net 0  Node 0    Offline rung 0  0  0        Fig  5 13 OMRON CX Programmer     6  Paste the source program in the Diagram view or Mnemonics view  And the in following dialogue box will    be displayed         Ladder Program Converter Verl 2    Caution    This software is only a supporting tool for ladder program  conversion  So you should review and debug the conversion  result in real application          Source PLO Type 
6.     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        491    OR       S1  lt  S2     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        492    ORD       S1  lt  S2     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ           KSZ  KMZ         TV  CZ  CV  DZ  DV  NO  conversion        493    OR lt  gt      S1   S2     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ         TV  CZ  CV  DZ  DV  NO  conversion           494       ORD lt  gt         S1 Z S2        Inline Comparisons                      Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        45154       Ladder Program Converter Operation Manual                                                                                                                                                      Fx   Convert        Instruction Function Class 3 2  1     1S   Status Remark  495   OR lt    S1 I S2  Inline Comparisons 9 0 eo   A Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion   496   ORD     S1 I S2  Inline Comparisons 9 0 eo e A Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion   497   OR gt    8S1   82  Inline Comparisons 9 0   eo e A Operand incl
7.    1S   Status Remark  93 DMUL Multiplication Arithmetic and 9 0   eo e A Operand includes KZ   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   94 DMULP Multiplication Arithmetic and 9 0 eo e A Operand includes KZ   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   95 DIV Division Arithmetic and 9 0 eo   A Operand includes KZ  KV   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion   96 DIVP Division Arithmetic and 9 0   eo e A Operand includes KZ  KV   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion   97 DDIV Division Arithmetic and 9 0   eo e A Operand includes KZ   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   98 DDIVP Division Arithmetic and 9 0 eo   A Operand includes KZ   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   99 INC Increment Arithmetic and 9 0 eo   A Operand includes KZ   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   100   INCP Increment Arithmetic and 9 0 eo e A Operand includes KZ   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   101   DINC Increment Arithmetic and eo oe eo A Operand includes          Logical operations KSZ  KMZ  TZ  CZ  NO  conversion   102   DINCP Increment Arithmetic and ee oe 9 A Operand includes          Logical operations KSZ  KMZ  TZ  CZ  NO  conversion   103   DEC Decrement Arithmetic and 9 0 eo e A Operand includes KZ   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   104   DECP
8.    BUSS      ze            PES   Ale alae        eal Fa Ea Bi  azman LL ziel  Hle z   ES  amp      2  m     alalta  27        Eilte  ele  TETTE II    mf    mlela  a  sael  alaa   lt el elal ale          SSeS est el ot  alaa  STE ON en NTN    x   E B  Unset project      Eg  Program  E MAIN   m Device comment  Parameter                      Device menory                 88  Project    Ready       0  Host station Ovrwrte       Fig 5 1 Mitsubishi GX Developer             12 54    Ladder Program Converter Operation Manual    Egh   2  ci al   enter the mnemonic list window     7  Project Edit Find Replace Convert View Online Diagnostics Tools Window Help   k           njan Bee ee   zfs eji  115  zlels  HS 5     eor  a  Hll  ml E ar     zat   pin miz Pon     Bm                             Unset project   Program  Eg  MAIN    Device comment                Parameter        Device memory       Mi          rave  Host station    Ovrwrte Z       Fig 5 2 Mitsubishi instruction list View     3  Select the Program needed to be converted and copy it     13 54    Ladder Program Converter Operation Manual     4  Start up CX Programmer and create a new project               new     CX Programmer      NewPLCI NewPrograml Sectionl  Diagram          File Edit View Insert Program PLC Simulation Tools Window Help  Deh             BR A           CM  m M RI Ee      SD  E  S  22 39 8    xl    NewProject     NewPLC1 CP1E  Offline    gt  Symbols   5  Settings          Memory    A Programs      Sg  NewProg
9.    E Status Chart   E  Data Block  BE Cross Reference   E  Output Window   i ymboll  symbols     B Instruction Tree Symbol  100  INT DUT F Symbol3 300 Status Display   E  Navigation Bar Symbal2 200 4 IN2     E Print    Symbolic Addressing   Display Symbol and Address                 Inside Instruction             Category       Type  MS Sans Serif zi  Style  Regular          Size  8 v       Sample Text       Network Title      Enable operand editing after placing instruction    t          Cancel Reset All       Fig 5 10    Options    Screen of Siemens    Select General in the left tree menu and International in the item of Mnemonic Set     General  Allows you to configure general software options     i  Options General   Defaults   Colors      Bez    BE Program Editor   Default Editor     Programming Mode   E  Symbol Table    STL Editor   SIMATIC  E Status Chart   Ladder Editor C IEC 1131 3     E  Data Block   C FBD Editor   E  Cross Reference N    E  Output Window Mnemonic Set URSUS   E  Instruction Tree   International      era Bar C SIMATIC  rin       Regional Settings    Measurement System   US     Time Format  12 hour X  Date Format   mm dd yy         Reset All            Fig 5 11    General    Screen of Siemens    19   54    Ladder Program Converter Operation Manual     3  Select view     STL  View the program in STL mode  Mnemonic list            5       T Nicro WIN     Projecti      SINATIC SIL   EJ File Edit View PLC Debug Tools Windows Help                          
10.   Fx   Convert  No  Instruction Function Class 3 2   1N   1S   Status Remark  73 DXCH Exchange Move and Compare         A To CP1E No Conversion   74 DXCHP Exchange Move and Compare 9019 A To CP1E No Conversion   75 BCD Conversion to Move and Compare 9 0 eo   A Operand includes KZ  KV   Binary Coded         KYZ  KSZ           Decimal TZ  TV  CZ  CV NO  conversion   76 BCDP Conversion to Move and Compare 9 0   eo   A Operand includes KZ  KV   Binary Coded         KYZ  KSZ           Decimal TZ  TV  CZ  CV NO  conversion   77 DBCD Conversion to Move and Compare 9 0   eo e A Operand includes KZ   Binary Coded KXZ  KYZ  KSZ  KMZ   Decimal TZ  CZ  NO conversion   78 DBCDP Conversion to Move and Compare 9 0   eo   A Operand includes KZ   Binary Coded         KYZ  KSZ  KMZ   Decimal TZ  CZ  NO conversion   79 BIN Conversion to Move and Compare 9 0 eo e A Operand includes KZ  KV   Binary         KYZ  KSZ           TZ  TV  CZ  CV NO  conversion   80 BINP Conversion to Move and Compare 9 0   eo e A Operand includes KZ  KV   Binary         KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion   81 DBIN Conversion to Move and Compare 9 0   eo e A Operand includes KZ   Binary         KYZ  KSZ  KMZ   TZ  CZ  NO conversion   82 DBINP Conversion to Move and Compare 9 0 eo   A Operand includes KZ   Binary KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   83 ADD Addition Arithmetic and 9 0 eo e A Operand includes KZ  KV   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion   84 ADDP Addit
11.   ge G R Akun       o 2 8 C       e gs   n  TAPAS a  gt  NN PA  gt   gt                   NewProject    NewPLCI CP1E  Offline    3 Symbols   5  Settings          Memory  E     Programs    8 NewProgrami  00     Symbols     Sectiont     amp  END             IF                     TAK k a emp sint  Decthation                     xFRB GE    Tracer Bie    1005    Corot wore    TENP_CH_02   Tak ka emp symbol br comerthg Rt abt prog ram   Fistsonrer word    HO Firztdeztihation word    TIME    100m  Timer Time n         Type      gt     Name     Address or Value  0 00 Comment                           r     Project   BE                Source step 5 Converted step  0                 Comment File converter log  gt  gt  gt  gt  gt  gt  gt   Converted TEMP      02 to W42        Compile    Find Report    Transfer   4    For Help  press Fi   NewPLC1 Net 0 Node 0    Offline rung 0  0  0    100     Smart NUM       Fig 5 7 the result of conservation    16   54    Ladder Program Converter Operation Manual     9  Insert the temporary variable created during the conversion into the global variable table     ew   CX Programmer    NewPLC1  Symbols     t9 File Edit View Insert Program PLC Simulation Tools Window Help              SEA LAK   IE Kalak sa e leaf Hmm       o Balk   m m Ra EAS  db               18      u    je               gt  m mp     Name  Datatype   Address Wale  Racktocation  Usage  Comment              AE Pes       42       AENG   B 1   T  0                                  10 39 1
12.  Decrement Arithmetic and 9 0   eo e A Operand includes KZ   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   105   DDEC Decrement Arithmetic and eo oe   A Operand includes          Logical operations KSZ  KMZ  TZ  CZ  NO  conversion   106   DDECP Decrement Arithmetic and ee oe o A Operand includes          Logical operations KSZ  KMZ  TZ  CZ  NO  conversion   107   WAND Logical Word AND   Arithmetic and 9 0 eo   A Operand includes KZ  KV   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion   108   WANDP Logical Word AND   Arithmetic and 9 0 eo e A Operand includes KZ  KV   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion   109   DAND Logical Word AND   Arithmetic and 9 0 eo e A Operand includes KZ   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   110   DANDP Logical Word AND   Arithmetic and 9 eo eo e A Operand includes KZ   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   111   WOR Logical Word OR Arithmetic and 9 0 eo e A Operand includes KZ  KV   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion   112   WORP Logical Word OR Arithmetic and 9 0   eo e A Operand includes KZ  KV   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion        31 54       Ladder Program Converter Operation Manual                                                                                                   Fx   Convert        Instruction Function Class 3 2  1     1S   
13.  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion   466   LD    S1  lt  S2  Inline Comparisons 9 0 eo e A Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion   467   LDD gt   S1  gt  S1  Inline Comparisons 9 0   eo e A Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion   468   LDD    S1  lt  S2  Inline Comparisons 9 0 eo e A Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion                                   43154       Ladder Program Converter Operation Manual       No     Instruction    Function    Class    Fx    Fx  1N    Fx  1S    Convert  Status    Remark       469    LD lt  gt      S1   S2     Inline Comparisons    A    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        470    LDD lt  gt      S1 Z S2     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        471    LD        S1          52     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ         TV  CZ  CV  DZ  DV  NO  conversion        472    LDD        S1          52     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        473    LD gt       S1 0        S2     Inline Comparisons    Op
14.  Ladder Program Converter  This tool is used to convert the instructions of Mitsubishi and Siemens to instructions of OMRON according    to the conversion rules     Operation Environment   Operation System   Ladder Program Converter can only run in Microsoft Windows 2000  Service Pack2 or higher    Microsoft  Windows XP  Microsoft Windows Vista  32bit version      Object PLC Series  PLC type of Conversion Source includes FX3 2 1N 1S of Mitsubishi as well as S7 200 series of Siemens   OMRON PLC type of Conversion Destination is CP1H CP1L CP1E     8 54    3     3 1     3 2     Ladder Program Converter Operation Manual    Installation and uninstall   Installation   The install steps are as follows     1  Uninstall the previous version of Ladder Program Converter before installing the new version  Please  refer to the section 3 2 for details of the method of uninstall     2  Copy the install files of Ladder Program Converter to object folder specified by users     3  Run    setup exe    in the install files     4  Install Ladder Program Converter according to the installation prompts    Note    When installing CX Programmer 9 0  the converter tool    Ladder Program Converter v1 1  will be   installed at the same time  For the new version with  Ladder Program Converter v1 2   please refer   to the above install step  2     4     Uninstall   Please perform the Uninstall of Ladder Program Converter through the Add Remove Programs    Select Start  Setting   Control Panel   Add Remove
15.  Memory Point Contact Instruction 9 0   oe 0 O  Store  16 MRD Memory Read Contact Instruction 9    09   O  17 MPP Memory POP Contact Instruction 9    eo oe O  18 INV Inverse Contact Instruction e e e e O  19 MEF MEF Contact Instruction e O  20 MEP MEP Contact Instruction e oO  21 OUT Out Out Instruction e e e e Q  22 OUT  C  Out Out Instruction 9 0   eo eo O  23 OUT  T  Out Out Instruction 9    eo eo O  24 SET Set Out Instruction e e e e O  25 RST Reset Out Instruction e e e e O  26 PLS Pulse Out Instruction e e e e O  27 PLF Falling pulse Out Instruction e 0   eo oe O  28 MC Master Control Master Control e e e e O  Instruction  29 MCR Master control reset   Master Control e e e e O  Instruction  30 NOP No Operation Other Instruction 9    eo oe O  31 END End End Instruction e e e e O  32 STL Step Ladder Step Ladder 9 0   eo e x  Instruction  33 RET Return Step Ladder 9 0 eo e x  Instruction  34 CJ Conditional jump Program Flow 9 0   eo eo O  35 CJP Conditional jump Program Flow 9 0   0      O  36 CALL Call Subroutine Program Flow 9    vo oe O  37 CALLP Call Subroutine Program Flow 9       eo 9 O  38 SRET Subroutine Return Program Flow 9 0   eo oe O  39 IRET Interrupt Return Program Flow 9 0   0          40      Enable linterrupt Program Flow 9 0    o    O  41 DI Disable Interrupt Program Flow    0    e 9 O  42 FEND Main Routine Program Flow eo oe   O  Program End  43 WDT Watchdog Timer Program Flow 9 0   oe   O  Refresh  44 WDTP Watchdog Timer Program Flow 9 0   ojo O  Refres
16.  Move and Compare ee oe o0 A Operand includes       KV           KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion    56 MOVP Move Move and Compare ee oe 9 A Operand includes       KV                   KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion    57 DMOV Move Move and Compare ee oe o0 A Operand includes KZ                   KSZ  KMZ                   conversion    58 DMOVP Move Move and Compare ee oe 0 A Operand includes KZ                   KSZ  KMZ                   conversion    59 SMOV Shifi Move Move and Compare         x   60 SMOVP Shift Move Move and Compare         x   61 CML Complement Move and Compare 919 O   62 CMLP Complement Move and Compare         O   63 DCML Complement Move and Compare         A To CP1E No Conversion    64 DCMLP Complement Move and Compare         A To CP1E No Conversion    65 BMOV Block Move Move and Compare 9 0   ojo    Operand includes KZ  KV           KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion    66 BMOVP Block Move Move and Compare 9 0 eo e A Operand includes KZ  KV           KYZ  KSZ  KMZ   TZ  TV  CZ  CV NO  conversion    67 FMOV Fill Move Move and Compare         x   68 FMOVP Fill Move Move and Compare         x   69 DFMOV Fill Move Move and Compare 9019      70 DFMOVP Fill Move Move and Compare 919                  Exchange Move and Compare 9 9 O   72 XCHP Exchange Move and Compare 9 9 O       29   54       Ladder Program Converter Operation Manual                                                                      3 z Fx   Fx   Fx 
17.  NewPLC1 Qet 0  Node 0    Offline  rung 0  2  15    30    Classic           Fig  5 18 Insert temporary variable    24154    Ladder Program Converter Operation Manual    5 3  Conversion List File    Conversion List File is the instruction list before and after the conversion  It is a CSV file      1  Conversion List File specification    6 columns   1  Conversion Source Step  Step No  for Mitsubishi instruction  NetWork No  for Siemens  instruction   2  Conversion Source Instruction  3  Conversion Source Operand  4  Conversion Destination Step  5  Conversion Destination Instruction  6  Conversion Destination Operand    When the conversion type is 1    quse only the first OMRON instruction of conversion destination has    the Step No   When the instruction conversion error occurs  the instruction of conversion destination has not Step No     When the operand conversion error occurs  the Step No  will be generated normally   When converting the Mitsubishi program by the COPY PASTE conversion method  the content of CSV file  first column  Conversion Source Step  is not the Step No  in GX D but the Instruction Quantity No      Note 1     One source instruction is converted to more than one destination instruction or one source    instruction being converted to one destination instruction with different number and order of    operands     2  Open the CSV File in Excel  When Opening the CSV file in Excel  please pay attention to the following items     1     When the operand of OMRO
18.  OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL  INDIRECT  OR CONSEQUENTIAL DAMAGES   LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS     WHETHER SUCH CLAIM IS BASED ON CONTRACT  WARRANTY  NEGLIGENCE  OR STRICT  LIABILITY     3 54    Ladder Program Converter Operation Manual    3  SUITABILITY FOR USE    OMRON shall not be responsible for conformity with any standards  codes  or regulations that apply to the  combination of products in the customer s application or use of the products     At the customer s request  OMRON will provide applicable third party certification documents identifying  ratings and limitations of use that apply to the products  This information by itself is not sufficient for a  complete determination of the suitability of the products in combination with the end product  machine   system  or other application or use     The following are some examples of applications for which particular attention must be given  This is not  intended to be an exhaustive list of all possible uses of the products  nor is it intended to imply that the uses  listed may be suitable for the products        Outdoor use  uses involving potential chemical contamination or electrical interference  or conditions or  uses not described in this manual    e Nuclear energy control systems  combustion systems  railroad systems  aviation systems  medical  equipment  amusement machines  vehicles  safety equipment  and installations subject to separate  industry or g
19.  Operation 2 919 A Operand includes address                               out of converter range and  KY  KM  KS  TV  TZ   CV  CZ  DV  DZ           KSZ  KMZ  NO  conversion        38   54       Ladder Program Converter Operation Manual                                                                                                                   z Fx   Fx   Fx   Fx   Convert  No  Instruction Function Class 3 2 AN   4S   Status Remark  333   DSWAP Float to Scientific Data Operation 2 919 A Operand includes address  out of converter range and  KY  KM  KS  TV  TZ   CV  CZ  DV  DZ  KYZ   KSZ  KMZ  NO  conversion   334   DSWAPP Float to Scientific Data Operation 2 919 A Operand includes address  out of converter range and  KY  KM  KS  TV  TZ   CV  CZ  DV  DZ           KSZ  KMZ  NO  conversion   335   SORT2 Sort Tabulated Data Operation 2 e x  Data 2  336   DSORT2 Sort Tabulated Data Operation 2 e x  Data 2  337   DSZR DOG Search Zero Positioning Control e x  Return  338   DVIT Interrupt Positioning Control e x  Positioning  339   DDVIT Interrupt Positioning Control e x  Positioning  340   DTBL Batch Data Positioning Control e x  Positioning Mode  341   DABS Absolute current Positioning Control 9 0   eo e x  value read  342   ZRN Zero return Positioning Control e  o 09 e x  343   DZRN Zero return Positioning Control 9 0   0          344   PLSV Pulse V Positioning Control 9 0   eo e x  345   DPLSV Pulse V Positioning Control 9 0   0          346   DRVI Drive to increment Positioni
20.  Programs    Select Ladder Program Converter from the dialogue box    Click the Remove Button    And then finish uninstall under the instruction of install shield wizard     Note     1  Please don t delete the folder where Ladder Program Converter is installed directly  otherwise  the operation of reinstall and uninstall can t carry out correctly     2  If the converter tool is installed  updated  in the CX Programmer 9 0  it can t be uninstalled  without CX Programmer 9 0  When uninstalling CX Programmer 9 0  the converter tool will be  uninstalled at the same time     9 54    Ladder Program Converter Operation Manual    4  Notice about the conversion  4 1  Notice of the Copy Paste Conversion Method     1  Setting FX3 2 1N 1S series of Mitsubishi as the copy source has been tested  The program of    other series PLC could not be identified      2  In Omron CX P  paste can be performed in the Diagram view and Mnemonic view of Section    3  The UNDEFINST will be output when Instruction of Mitsubishi can not be identified  The UNDEFOPER  will be output to substitute for the operand of Mitsubishi which can not be identified     before the Mitsubishi instruction and a  Si      conversion result in the CXT file     otherwise some programs will lost     When the Source instruction can not been converted to the OMRON instruction  a  Mi   will be added  will be added before the Siemens instruction as the    That copy from Siemens program should start with Network 1 and the minimum co
21.  e Operand includes TZ  TV   CZ  CV  NO conversion    153   DECO Decode Data Operation ee oe 0 Operand includes       KV   KX  KY  KS  KM                   KSZ  KMZ TZ   TV        CV  NO  conversion    154   DECOP Decode Data Operation ee oe   A Operand includes KZ  KV         KY  KS  KM                   KSZ          TZ   TV        CV  NO  conversion    155   ENCO Encode Data Operation ee oe 0 A Operand 1 isn t T  C  D   V      DZ  DV  NO  conversion    Operand 2 isn t T  C  D   V      DV  DZ  NO  conversion                                   33   54       Ladder Program Converter Operation Manual                                                                                                                                 5 Fx   Fx   Fx   Fx   Convert  No  Instruction Function Class 3 2  1     1S   Status Remark  156   ENCOP Encode Data Operation ee oe o A Operand 1 isn t T  C  D   V      DZ  DV  NO  conversion   Operand 2 isn t T  C  D   V      DV  DZ  NO  conversion   157   SUM Sum of Active Bits Data Operation 919     158   SUMP Sum of Active Bits Data Operation 919     159   DSUM Sum of Active Bits Data Operation 9019     160   DSUMP Sum of Active Bits Data Operation         x  161   BON Check Specified Bit   Data Operation 919     Stauts  162   BONP Check Specified Bit   Data Operation 919     Stauts  163   DBON Check Specified Bit   Data Operation 919     Stauts  164   DBONP Check Specified Bit   Data Operation 919     Stauts  165   MEAN Mean Data Operation 9019     16
22.  in text     The filled circle symbol indicates operations that you  must do  The specific operation is shown in the circle  and explained in text  This example shows a general  precaution for something that you must do     6 54    Ladder Program Converter Operation Manual  The triangle symbol indicates precautions  including    warnings   The specific operation is shown in the  triangle and explained in text  This example indicates  a general precaution     The triangle symbol indicates precautions  including  warnings   The specific operation is shown in the  triangle and explained in text  This example indicates  a precaution for hot surfaces             WARNING       This tool is just used to convert the instructions of Mitsubishi and  Siemens to instructions of OMRON according to the conversion rules as  much as possible  Because the ladder program can not be converted  completely  it is necessary to modify the instructions and memory area  which have not been converted  The operation of the made ladder  program must be confirmed enough before carrying out a formal  operational    System operation may be abnormal without confirmation              The I O memory convert specification is made before instruction  conversion  If you want to add program after conversion  it is necessary  to confirm there is no repetition of      memory     System operation may be abnormal without confirmation           7154    2 1     2 2     Ladder Program Converter Operation Manual    About
23. 1 gt S2   411   DBKCMP gt  Block Data Block Data Operation   6 x  Compare S1 gt S2   412   DBKCMP gt P Block Data Block Data Operation   6 x  Compare S1 gt S2   413   BKCMP lt  Block Data Block Data Operation   6 x  Compare S1 lt S2   414   BKCMP lt P Block Data Block Data Operation   6 x  Compare S1 lt S2   415   DBKCMP lt  Block Data Block Data Operation   6 x  Compare S1 lt S2   416   DBKCMP lt P Block Data Block Data Operation   6 x  Compare S1 lt S2   417   BKCMP lt  gt  Block Data Block Data Operation   6 x  Compare S1 lt  gt S2   418   BKCMP lt  gt P Block Data Block Data Operation   6 x  Compare S1 lt  gt S2   419   DBKCMP lt  gt  Block Data Block Data Operation   6 x  Compare S1 lt  gt S2   420   DBKCMP lt  gt P   Block Data Block Data Operation   6 x  Compare S1 lt  gt S2   421   BKCMP lt   Block Data Block Data Operation   6 x  Compare S1 lt  S2   422   BKCMP lt  P Block Data Block Data Operation   6 x  Compare S1 lt  S2   423   DBKCMP lt   Block Data Block Data Operation   6 x  Compare S1 lt  S2   424   DBKCMP lt  P   Block Data Block Data Operation   6 x  Compare S1 lt  S2   425   BKCMP gt   Block Data Block Data Operation   6 x  Compare S1 gt  S2   426   BKCMP gt  P Block Data Block Data Operation   6 x  Compare S1 gt  S2   427   DBKCMP gt   Block Data Block Data Operation   6 x  Compare S1 gt  S2   428   DBKCMP gt  P   Block Data Block Data Operation   6 x  Compare S1 gt  S2   429   STR BIN to Character Character String e x  String Control  Conversion   430   S
24. 51 MOV_BIW Move Instructions Move Byte Immediate Write x  152  wANp            Operations   ang Byte     Instructions  153 WOR B Logical Operations Or Byte     Instructions  154   WXOR_B Logical praon Exclusive Or Byet O  Instructions  155  WAND w   LegicalOperalons_   And Word     Instructions  156  wor w   Logical Operations   Word     E Instructions  157   WXOR_W logical ne Exclusive Or Word O  Instructions  158   WAND pw   Logical Operations   Ang Double Word O  Instructions  159  woR pw   Logical Operations   O  Double Word O  Instructions  160  WXOR pw   Logical Operations Exclusive Or Double Word O  Instructions  161  INV B Logical Operations     jis Byte     Instructions  162   INV_W Logical      Invert Word  O  Instructions  163  INV DW Logical         Invert Double Word O  Instructions                         51 54    Ladder Program Converter Operation Manual                                                                                                       Instruction    Convert  No   S7 200  Class Function Status Remark   164  SHR B Shift and Rotate Shift Right Byte x    Instructions   165  SHL B Snift and Rotate Shift Left Byte x    Instructions   166   SHR W       Shift Right Word     Instructions   167   SHL_W ani and Rotate Shift Left Word O  RT Instructions   168    SHR DW     Shiffand Rotate Shift Right Double Word O  Instructions   169   sH pw   Shift and Rotate Shift Left Double Word O  Instructions   170   ROR_B snitt ang Ba Rotate Right Byte x  Instruc
25. 536   LOADRP Load From ER Extension File e x  Register Control  537   SAVER Save to ER Extension File e x  Register Control  538   INITR Initialize Rand ER Extension File e x  Register Control  539   INITRP Initialize Rand ER Extension File e x  Register Control  540   LOGR Logging Rand ER Extension File e x  Register Control  541   LOGRP Logging Rand ER Extension File e x  Register Control  542   RWER Rewrite to ER Extension File e x  Register Control  543   RWERP Rewrite to ER Extension File e x  Register Control  544   INITER Initialize ER Extension File e x  Register Control  545   INITERP Initialize ER Extension File e x             Register Control                            47154     2  Siemens PLC Instruction Convert List     Note  Specific conversion information  refer to Appendix  Siemens Convert Specification     Ladder Program Converter Operation Manual                                                                                                                                                       No  an Class Function Fe Remark  1 AENO Bit Logic Instructions   And ENO O  2 LD Bit Logic Instructions   Load O  3 LDN Bit Logic Instructions Load Not O  4 A Bit Logic Instructions   And O  5 AN Bit Logic Instructions   And Not O  6 O Bit Logic Instructions   Or O  7 ON Bit Logic Instructions   Or Not O  8 LDI Bit Logic Instructions Load immediate O  9 LDNI Bit Logic Instructions Load Not immediate O  10 Al Bit Logic Instructions   And immediate O  11 ANI Bit Logic I
26. 6              Mean Data Operation 919     167   DMEAN Mean Data Operation         x  168   DMEANP Mean Data Operation 919     169   ANS  Timed Annunciator   Data Operation 919     Set  170   ANR Annunciator Reset Data Operation         x  171   ANRP Annunciator Reset Data Operation         x  172   SQR Square Root Data Operation 9019     173   SQRP Square Root Data Operation 919     174   DSQR Square Root Data Operation 9 9         CP1E No Conversion   175   DSQRP Square Root Data Operation 9 9 A To CP1E No Conversion   176   FLT Conversion to Data Operation e oe O  Floating Point  177   FLTP Conversion to Data Operation e    O  Floating Point  178   DFLT Conversion to Data Operation e oe O  Floating Point  179   DFLTP Conversion to Data Operation e oe O  Floating Point  180   REF Refresh High Speed 9 0   eo e x  Processing  181   REFP Refresh High Speed 9 0   eo e x  Processing  182   REFF Refresh and filter High Speed 9 0 eo e x  adjust Processing  183   REFFP Refresh and filter High Speed 9 0 eo   x  adjust Processing  184   MTR Input matrix High Speed 9 0   eo e x  Processing  185   DHSCR High speed cunter High Speed 9 0 eo e x  reset Processing  186   DHSCS High speed cunter High Speed 9 0 eo e x  set Processing  187   DHSZ High speed zone High Speed 919     compare Processing  188   SPD Speed detection High Speed 9 0   eo e x  Processing  189   DSPD Speed detection High Speed e x  Processing  190   PLSY Pulse Y output High Speed 9 0   eo e x  Processing  191   DPLSY Pu
27. 6    zd ad                      gt     5 NewProject A                 BOOL CF004 work Carry  CY  Flag    NewPLC1 CP1E  Offline   P_Cycle_Time_Error BOOL A401 08 Work Cycle Time Error Flag  2 Symbols  p Cyde Time  Value UDINT A264 Work Present Scan Time  3 Settings   PEQ BOOL            Work Equals  EQ  Flag  PEN er   PER BOOL CF003 Work Instruction Execution Error  ER  Flag  kn G      iux    P First Cyde BOOL A200 11 Work First Cycle Flag  C3 symbols   P First Cycle Task BOOL A200 15 Work First Task Execution Flag  E   P_GE BOOL CFOOO  ork Greater Than or Equals  GE  Flag  8 Sectioni Work h Is  GE  Fl     Pi L ori reater Than lag       END P_GT BOOI CFOS Work Greater Than  GT  Fl     PIE BOOL CF002 Work Less Than or Equals  LE  Flag    P Low Battery BOOL 4402 04 Work Low Battery Flag          BOOL CF007 Work Less Than  LT  Flag    P Max Cycle Time UDINT A262 Work Maximum Cycle Time     PN BOOL CFOOS Work Negative  N  Flag    PNE BOOL CF001 Work Not Equals  NE  Flag    POF BOOL  lt F009 Work   Overflow  OF  Flag    P  off BOOL CF114 Work Always OFF Flag    P On BOOL CF113 Work Always ON Flag    P  Output  Off Bit BOOL 4500 15 Work Output OFF Bit    P_Step BOOL A200 12 Work Step Flag    PUF BOOL CFO10 Work   Underflow  UF  Flag l   Project       TEMP CH 02 CHANNEL w42 Work This is a temp symbol for converting                     Source step 5 Converted step                  Comment File converter log  gt  gt  gt  gt  gt  gt  gt   Converted TEMP_CH_02 to wW42      ES 2j    For H
28. 8   DRCLP Rotation Left with Rotation and Shift       x  Carry Operation  139   SFTL Bit Shift Left Rotation and Shift ee oe o A  Operation  140   SFTLP Bit Shift Left Rotation and Shift 9 0   oe o A  Operation  141   SFTR Bit Shift Right Rotation and Shift ee oe o0 A  Operation  142   SFTRP Bit Shift Right Rotation and Shift ee oe 9 A  Operation  143   WSFR Word Shift Right Rotation and Shift 919     Operation  144   WSFRP Word Shift Right Rotation and Shift 919     Operation  145   WSFL Word Shift Left Rotation and Shift 919     Operation  146   WSFLP Word Shift Left Rotation and Shift 919     Operation  147   SFWR Shift write Rotation and Shift ee oe 0 A Operand 1 includes KZ    FIFO FILO control  KV                  KSZ   KMZ  TZ  TV  CZ  CV  NO  conversion   Operand 2 isn t T  C  D   NO conversion   148   SFWRP Shift write Rotation and Shift ee oe o0 A Operand 1 includes KZ    FIFO FILO control  KV                  KSZ   KMZ  TZ  TV  CZ  CV  NO  conversion   Operand 2 isn t T  C  D   NO conversion   149   SFRD Shift Read  FIFO Rotation and Shift ee oe   A Operand 1 isn t T  C  D   Control  NO conversion   Operand 2 isn t T  C  D   V      DV  DZ  NO  conversion    150   SFRDP Shift Read  FIFO Rotation and Shift ee oe   A Operand 1 isn t T  C  D    Control  NO conversion   Operand 2 isn t T  C  D   V      DV  DZ  NO  conversion    151   ZRST Zone Reset Data Operation 9 0 eo   A Operand includes TZ  TV   CZ  CV  NO conversion    152   ZRSTP Zone Reset Data Operation 9 eo eo
29. IO corresponds a physical I O   Mitsubishi area The area C200 C255 of Mitsubishi is 32 bits length     C200 C255 gt  Omron area The area C200 C255 of Omron is 16 bits length   C200 C255       When data is beyond max  range in Mitsubishi  the result is  recalculated from 0  The carry flag is active    When data is less than min  range in Mitsubishi  the result is  recalculated from 0  The borrow flag is active    The flag couldn t reset until changing next time    Ex when the operand is 16 bit length   32767 1 0  32768 1 0  The carry and borrow flag is the same flag  CF  in Omron   The marker bit and the   It s the difference with that in Mitsubishi    structure of arithmetic is   CF is active when data changes from plus to negative or from  difference  negative to plus    When data is beyond max  range in Omron  the data is cycle  operation The overflow flag is active    When data is less than min  range in Omron  the data is cycle  operation  The underflow flag is active    The flag will reset next cycle    Ex when the operand is 16 bit length   32767 1  32768  32768 1 32767   The pulse instruction of Mitsubishi P instruction will execute one time after contact M8000        Mitsubishi is difference with   Omron   instruction won t execute after cotact P  on   that of Omron       Sequence Control Mitsubishi s sequence control logo can t be converted So Function  Instructions and can not be achieved    SUBROUTINE instructions  will no function after being  converted       ol t
30. Ladder Program Converter    Operation Manual    Rev  V1 20    Ladder Program Converter Operation Manual    CONTENTS    About Ladder Program Converter           uu4444444HRRRRRRRnnnn nennen nennen nn nenn 8    Operation Environment    u  ca een ea aaa anaes 8  2 1  OS Object Operation System         uunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 8  2 2  Object PLC Series           nnna 8    Installation and uninstall                                      eeeeeeeeeeeeeeeeeeeeeeeeeeeeeneee 9  3 1  installation m nn 9  3 2  Uninstall  ass 9    Notice about the conversion               24444444444000nnnnnnnnnnnnn nenn nun nnnnnnnnnnnnnnnn 10  4 1  Notice of the Copy Paste Conversion Method                              10  4 2  Conversion                                 5                                                                                                    10    Copy Paste Conversion Method                                                            12  5 1  Copy Program from GX Developer of Mitsubishi                          12  5 2  Copy Program from STEP 7 MicroWIN of Siemens                      18  5 3  Conversion List File    222 25    ERROR List and Solutions    27  EM jp qe                       Ka 28  7 1  Instruction Convert list    28    2154    Ladder Program Converter Operation Manual    Introduction    This manual contains information required to use the Ladder Program Converter   Please refer to the user s manual of PLC unit while you use Ladder Progr
31. N instruction is bool type and the decimal fraction part is 0  the  decimal fraction part will be lost  For example 0 00 will be displayed as 0    The  L   L    L and   L instruction of OMRON will be displayed as     NAME       Please modify it  manually    The          and    instruction of OMRON in excel will be as maths symbols  Please modify it  manually    Please edit the CSV file in Notepad  not in Excel     25154    Ladder Program Converter Operation Manual     3  Conversion Example  Example of Mitsubishi                                SrcStep Srelnst SrcMem DstStep Dstlnst DstMem  0 LD X000 0 LD 0 00  1 BIN TO 1 BIN  023    TO  T1  No Step number  T1  LD X001 2 LD 0 01  REF X000  No Step number    MI REF X000  KO  No Step number  KO  12 END 3 END                         Example of Siemens                                            SrcStep Srelnst SrcMem DstStep Dstlnst DstMem   NetWork 1 LD 10 0 0 LD 0 00   NetWork 1 MOVW VWO 1 MOV  021    DO  VW2  No Step number  D2   NetWork 2 LD 10 1 2 LD 0 01   NetWork 2 STR VBO  No Step number    SI_STR VBO  VB1  No Step number  VB1  VB2  No Step number  VB2   END   ORGANIZATION ENDP 3 END   BLOCK                26154    Ladder Program Converter Operation Manual    6  ERROR Listand Solutions       Error List Solutions         Choose the    Generated a  Converting list file conversion list    and click the       OK    button when the path and  A the Herne i pn  name of conversion list file is    not designated  The warning  will b
32. Status Remark  113   DOR Logical Word OR Arithmetic and 9 0   eo e A Operand includes KZ   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   114   DORP Logical Word OR Arithmetic and 9 0 eo e A Operand includes KZ   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   115   WXOR Logical Exclusive Arithmetic and 9 0 eo   A Operand includes KZ  KV   OR Logical operations KXZ  KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion   116   WXORP Logical Exclusive Arithmetic and 9 0   eo e A Operand includes KZ  KV   OR Logical operations KXZ  KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion   117   DXOR Logical Exclusive Arithmetic and 9 0   eo e A Operand includes KZ   OR Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   118   DXORP Logical Exclusive Arithmetic and       ojo A Operand includes KZ   OR Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   119   NEG Negation Arithmetic and       Operand includes address  Logical operations out of converter range and  KY  KM  KS  TV  TZ   CV  CZ  DV  DZ  KYZ   KSZ  KMZ  NO  conversion   120   NEGP Negation Arithmetic and 919 A Operand includes address  Logical operations out of converter range and  KY  KM  KS  TV  TZ   CV  CZ  DV  DZ  KYZ   KSZ  KMZ  NO  conversion   121   DNEG Negation Arithmetic and 919 AN Operand includes address  Logical operations out of converter range and  KY  KM  KS  TV  TZ   CV  CZ  DV  DZ           KSZ  KMZ  NO  conversion   To CP1E  NO conversion   122   DNEGP Negat
33. TRP BIN to Character Character String e x  String Control  Conversion   431   DSTR BIN to Character Character String e x  String Control  Conversion   432   DSTRP BIN to Character Character String e x  String Control  Conversion                                     41154    Ladder Program Converter Operation Manual                                                                   No  Instruction Function Class n  En A ee Remark  433   VAL Character String to   Character String e x  BIN Control  Conversion  434   VALP Character Stringto   Character String e x  BIN Control  Conversion  435   DVAL Character Stringto   Character String e x  BIN Control  Conversion  436   DVALP Character Stringto   Character String e x  BIN Control  Conversion  437      Link Character Character String e A To CP1E No Conversion   Strings Control  438     P Link Character Character String e To CP1E No Conversion   Strings Control  439   LEN Character String Character String e To CP1E No Conversion   Length Control  Detection  440   LENP Character String Character String e A To CP1E No Conversion   Length Control  Detection  441   RIGHT Extracting Character String e A Operand includes address  Character String Control out of converter range and  Data from the Right KX  KY  KM  KS  TV   TZ  CV  CZ  DV  DZ           KYZ  KSZ           NO conversion   To CP1E No Conversion   442   RIGHTP Extracting Character String e A Operand includes address  Character String Control out of converter range and  Data fr
34. Transfer Control  453   FDEL Deleting Data from Data Operation 3 e A Operand includes address  Tables out of converter range and  TV  TZ        CZ  DV   DZ  NO conversion   To CP1E No Conversion   454   FDELP Deleting Data from Data Operation 3 e A Operand includes address  Tables out of converter range and  TV  TZ        CZ  DV   DZ  NO conversion   To CP1E No Conversion   455   FINS Inserting Data to Data Operation 3 e A Operand includes address  Tables out of converter range and  TV  TZ        CZ  DV   DZ  NO conversion   To CP1E No Conversion   456   FINSP Inserting Data to Data Operation 3 e A Operand includes address  Tables out of converter range and  TV  TZ        CZ  DV   DZ NO conversion   To CP1E No Conversion   457   POP Shift Last Data Data Operation 3 e x  Read  FILO Control  458   POPP Shift Last Data Data Operation 3 e x  Read  FILO Control  459   SFR Bit Shift Right with Data Operation 3 9 O  Carry  460   SFRP Bit Shift Right with Data Operation 3 6 O  Carry  461   SFL Bit Shift Left with Data Operation 3 e oO  Carry  462   SFLP Bit Shift Left with Data Operation 3 e O  Carry  463   LD   S1   S2  Inline Comparisons 9 0 eo e A Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion   464   LDD   S1   S2  Inline Comparisons 9 0   eo   A Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion   465   LD    S1  gt  S1  Inline Comparisons 9 0   eo e A Operand includes KZ 
35. am Converter     Intended Audience    This manual is intended for the following personnel  who must also have knowledge of electrical systems   an electrical engineer or the equivalent      e Personnel in charge of installing FA systems   e Personnel in charge of designing FA systems     e Personnel in charge of managing FA systems and facilities     Note    This manual contains information required to use the Ladder Program Converter     Read this manual completely and be sure you understand the contents before attempting to use the Ladder  Program Converter     Pease keep the manual and always keep it at hand after reading     Read and Understand this Manual    1     WARRANTY   This software is used to convert the instructions of FX3 2 1N 1S series made by Mitsubishi Electric  Corporation and S7 200 series made by Siemens to OMRON instructions according to the conversion rules  as much as possible    OMRON MAKES NO WARRANTY OR REPRESENTATION  EXPRESS OR IMPLIED  REGARDING  NONINFRINGEMENT  MERCHANTABILITY  OR FITNESS FOR PARTICULAR PURPOSE OF THE  PRODUCTS     After conversion operation  the Programmable Logic Controller is responsible for the operation of  CX Programmer  Please refer to the programmable manual of our company   Related Manuals    CP1H CPU Unit Operation Manual  Cat  No W450     CP1L CPU Unit Operation Manual  Cat  No W462   CP1E CPU Unit Hardware User s Manual  Cat  No  W479   CP1E CPU Unit Software User s Manual  Cat  No  W480     LIMITATIONS OF LIABILITY 
36. as In Mitsubishi PLC  program can be divided into a shorter period of  WDT function is changed   x j l    time  through WDT  watchdog timer  monitor the cycle time   after being converted       EI DI function is changed The Mitsubishi PLC default disable interrupts   after being converted The Omron PLC default ensable interrupts          To ASC instructions  if the string of first operand contains symbol           The function of ASCII code        us then the characters after this symbol will be abandoned  If this string  instructions is difference    f contains two or more symbols          then the second operand will be  after being converted             abandoned too        11 54    Ladder Program Converter Operation Manual    5  Copy Paste Conversion Method in CX P    The Ladder Program Converter supports copying the program from the conversion source software     Mitsubishi GX Developer  Siemens STEP 7 MicroWIN  directly and pasting to the CX Programmer 9 0     CX Programmer for CP1E 1 00 or higher Version   5 1  Copy Program from GX Developer of Mitsubishi    Only Fx3 2 1N 1S series PLC of Mitsubishi supports the direct copy method  The integrity of program    reading can not be guaranteed when the method are used to other series PLC      1  Open the source program in GX Developer         EELSOFI series GX Developer  Unset project       LD Edit mode  9 Stepl    C  Project Edit Find Replace Convert View Online Diagnostics Tools Window Help                                
37. ation   6 x  BIN  Conversion  519   BINDA BIN to Decimal Data Table Operation   6 x  ASCII  Conversion  520   BINDAP BIN to Decimal Data Table Operation   6 x  ASCII  Conversion  521   DBINDA BIN to Decimal Data Table Operation   6 x  ASCII  Conversion  522   DBINDAP BIN to Decimal Data Table Operation   6 x          ASCII  Conversion                            46   54       Ladder Program Converter Operation Manual                                                                                 5 Fx   Fx   Fx   Fx   Convert  No  Instruction Function Class 3 2 AN   4S Status Remark  523   SCL2 Scaling 2 Data Table Operation   6 x   Coordinate by X Y  Data   524   SCL2P Scaling 2 Data Table Operation   6 x   Coordinate by X Y  Data   525   DSCL2 Scaling 2 Data Table Operation   6 x   Coordinate by X Y  Data   526   DSCL2P Scaling 2 Data Table Operation   6 x   Coordinate by X Y  Data   527   IVCK Inverter Status External Device e x  Check Communication  528   IVDR Inverter Drive External Device e x  Communication  529   IVRD Inverter Parameter External Device e x  Read Communication  530   IVWR Inverter Parameter External Device e x  Write Communication  531   IVBWR Inverter Parameter External Device e x  Block Write Communication  532   RBFM Divided BFM Read Data Transfer 3 e x  533   WBFM Divided BFM Write Data Transfer 3     x  534   DHSCT High Speed High Speed e x  Counter Compare Processing 2  With Data Table  535   LOADR Load From ER Extension File e x  Register Control  
38. c Stack Logic Read O  Instructions  218   LPP Logic Stack Logic Pop O  Instructions  219   LDS Ede PM Load Stack x  Instructions  220   HDEF pligh Spsed Counter High Speed Counter Definition x  Instructions  221 HSC High Speed ounter High Speed Counter x  Instructions  222   PLS High Speed Counter   pulse Output x  Instructions  223   READ_RTC   Clock Instructions Read Time Clock  224   SET_RTC Clock Instructions Set Read Time Clock  225 LA Clock Instructions Read Real Time Clock Extended x          53154    Ladder Program Converter Operation Manual                                                                                           No  ne Class Function ps Remark  226   SET_RTCX   Clock Instructions Set Real Time Clock Extended x  227   ATT Table Instructions Add to Table x  228   FND  Table Instructions Table Find x  229   FND lt  gt  Table Instructions Table Find x  230   FND lt  Table Instructions Table Find x  231 FND gt  Table Instructions Table Find x  232   FIFO Table Instructions First In First Out x  233   LIFO Table Instructions Last In First Out x  234   FILL Table Instructions Memory Fill x  235   ATCH Interrupt Instructions Attach Interrupt x  236   DTCH Interrupt Instructions Detach Interrupt x  237              Interrupt Instructions Conditional Return from Interrupt x  238  ENI Interrupt Instructions Enable Interrupt x  239   DISI Interrupt Instructions Disable Interrupt x  240   CEVNT Interrupt Instructions Clear Interrupt Event x  241 NETR Fe Network R
39. ck pulse bit  SW ees   P_AER BOOL CFO11 Work Access Error Flag  cO NewProgrant  00    PCY BOOL CFOD4 Work Carry  CY  Flag    PoCycle Time Error BOOL 4401 08 Work Cycle Time Error Flag       Cycle Time Value     UDINT A264 Work Present Scan Time    PEQ BOOL CFOOB Work Equals  EQ  Flag    PER BOOL CF003 Work Instruction Execution Error    R  Flag    P_First_Cycle BOOL A200  11 Work First Cycle Flag    P First Cycle Task BOOL A200  15 Work First Task Execution Flag    PGE BODL         Work Greater Than or Equals  GE  Flag    PGT BOOL CFOOS Work Greater Than  GT  Flag    PIE BOOL CF002 Work Less Than or Equals  LE  Flag    P Low Battery BOOL A402  04 Work Low Battery Flag    RIT BOOL CFOOT Work Less Than  LT  Flag       Mar Cycle Time UDINT A262 Work Maximum Cycle Time       BOOL CFO008 Work Negative  N  Flag    PONE BOOL CFOO1 Work Not Equals  NE  Flag    POF BOOL cF009 Work Overflow  OF  Flag    POff BOOL CF114 Work Always OFF Flag    P_On BOOL CF113 Work Always ON Flag    P Output O     Bit BOOL A500  15 Work Output OFF Bit    P_Step BOOL 4200 12 Work Step Flag  RUF BODL CF010 Work Underflow  UF  Flag             CH O01 CHANNEL Hal Work This is a temp symbol for converting Siemens p        TEMP CH 02 CHANNEL H42 Work This is a temp symbol for converting Siemens p       TEMP_CH_03 CHANNEL H43 Work This is a temp symbol for converting Siemens p        TEMP_CH_04 CHANNEL Had Work This is a temp symbol for converting Siemens p     Project    lt   gt           For SEES press Fl il 
40. e 99     Devices                                     35 54    Ladder Program Converter Operation Manual                                                                                                                  B Fx   Fx   Fx   Fx   Convert  No  Instruction Function Class 3 2 AN   4S Status Remark  233   DPRUNP Parallel run External FX Serial e e e e x  Devices  234   ASCI HEX to ASCII External FX Serial e e e e x  Devices  235   ASCIP HEX to ASCII External FX Serial e e e e x  Devices  236   HEX ASCII to HEX External FX Serial e e e e x  Devices  237   HEXP ASCII to HEX External FX Serial e e e e x  Devices  238   CCD Check Code External FX Serial e e e e x  Devices  239   CCDP Check Code External FX Serial e e e e x  Devices  240   VRRD Volume Read External FX Serial e e e e x  Devices  241   VRRDP Volume Read External FX Serial e e e e x  Devices  242   VRSC Volume Scale External FX Serial e e e e x  Devices  243   VRSCP Volume Scale External FX Serial e e e e x  Devices  244   RS2 Serial External FX Serial e x  Communication 2 Devices  245   PID PID Control Loop External FX Serial 6 eo    x  Devices  246   ANRD Analog Read Special Module e x  Instruction  247   ANRDP Analog Read Special Module e x  Instruction  248   ANWR Analog Write Special Module e x  Instruction  249   ANWRP Analog Write Special Module e x  Instruction  250   BLK BLOCK Special Module e x  Instruction  251   BLKP BLOCK Special Module e x  Instruction  252   MCDE Machine Code Special Module e x  I
41. e displayed        If the converter destination    GX Proerammer v9 0    PLC type is not supported  the  warning dialog box will display                    27154    7  Appendik    7 1  Instruction Convert list    Conversion status     O  Complete conversion    x  No conversion     1  Mitsubishi PLC Instruction Convert List   Note  Specific conversion information  refer to Appendix  Mitsubishi Convert Specification     Ladder Program Converter Operation Manual    A  Incomplete conversion  Restrict Condition   e  Corresponding Mitsubish PLC                                                                                                                                                                         A           Fx   Fx   Fx   Convert  No  Instruction Function Class 3 2 AN   4S Status Remark  1 LD Load Contact Instruction e e 9 9 O  2 LDI Load Inverse Contact Instruction 9 9 9 9 O  3 LDP Load Pulse Contact Instruction e e e e O  4 LDF Load Falling Pulse Contact Instruction 9 0   0      O  5 AND And Contact Instruction e e e e O  6 ANI And Inverse Contact Instruction e e e e O  7 ANDP And Pulse Contact Instruction e e e e O  8 ANDF And Falling Pulse Contact Instruction    0    e 9 O  9 OR Or Contact Instruction e e e e O  10 ORI Or Inverse Contact Instruction e e e e O  11 ORP Or Pulse Contact Instruction e e e e O  12 ORF Or Falling Pulse Contact Instruction        e 9 O  13 ANB And Block Contact Instruction e e e e oO  14 ORB Or Block Contact Instruction e e e e O  15 MPS
42. ead x  Instructions   242   NETW IE Network Write x  Instructions   243   XMT Communications Transmit x  Instructions   244   RCV Sa Receive x  Instructions   245   GET ADDR   Communications Get Port Address x  Instructions   246   SET ADDR   Communications Set Port Address x  Instructions   247   STR_LEN String Instructions String Length x   248   STR_CPY String Instructions Copy String x   249   STR_CAT String Instructions Concatenate String x   250   SSTR_CPY   String Instructions Copy Substring from String x   251 STR_FIND String Instructions Find String Within String x   252  CHR FIND   String Instructions Eind First charac Wikhin x             String                54154    
43. elp  press F1       NewPLC1 Net 0 Node 0    Offline   rung 0  0  D    100     smart   NUM          Fig  5 8 insert the temporary variable    17154    Ladder Program Converter Operation Manual    5 2  Copy Program from STEP 7 MicroWIN of Siemens  S7 200 series PLC of Siemens can be selected as the copy source      1  Open the program needed to be converted by STEP 7 MicroWIN of Siemens     f  STEP                       Projecti      SIMATIC LAD     Edit View PLO Debug Tools Windows Help                                                    FE au L H                     CPU 2    E Prograr        amp   Symbol      5  Status       Data Bl   AE  System PROGRAM COMMENTS  e  Cross F Network 1    10 0   E e Instructions      Favorite  3   8   Bit Logi   m Clock            41 Commu      Compa    Conver         Counte  8 Floatine       11 Integer                Internir Y   gt        Compiling Program Block     MAIN  081    SBR 0  SBR0    INT  0  INTO    Block Size   27  bytes   0 errors             Network 1 Row 3  Col 2 INS 7    Fig 5 9 STEP 7 MicroWIN of Siemens    18   54    Ladder Program Converter Operation Manual     2  Convert Siemens SIMATIC to International Symbol    When STEP 7 MicroWIN is started  click Tools menu or right button  select Options  the    Options    screen  is displayed     Program Editor  Allows you to configure the Program Editor by changing font  color  and other display options     Program Editor   STL Status    Preview ei    Ei   E  Symbol Table Width  100 
44. erand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        474    LDD gt       S1          52     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ         TV  CZ  CV  DZ  DV  NO  conversion        475    AND      S1   S2     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        476    ANDD      S1   S2     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        477    AND gt      S1  gt  S1     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        478    ANDD gt      S1  gt  S1     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        479    AND       S1  lt  S2     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ           KSZ  KMZ         TV  CZ  CV  DZ  DV  NO  conversion        480    ANDD       S1  lt  S2     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ         TV  CZ  CV  DZ  DV  NO  conversion           481       AND lt  gt         S1 Z S2        Inline Comparisons                      Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        44154       Ladder Program Conve
45. h          28   54    Ladder Program Converter Operation Manual                                                                                                                           B Fx   Fx   Fx   Fx   Convert  No  Instruction Function Class 3 2  1     1S   Status Remark  45 FOR Start of a For Next Program Flow 9 0   oe   A Operand includes       KV   loop                 KSZ  KMZ    TZ  TV  CZ  CV  NO  conversion    46 NEXT End a For Next Program Flow 9 eo eo e   loop   47 CMP Compare Move and Compare ee oe   A Operand includes KZ  KV           KYZ  KSZ  KMZ   TZ  TV        CV  NO  conversion    48 CMPP Compare Move and Compare ee oe 0 A Operand includes       KV           KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion    49 DCMP Compare Move and Compare eo oe o A Operand includes KZ           KYZ  KSZ  KMZ   TZ  CZ NO conversion    50 DCMPP Compare Move and Compare ee oe o0 A Operand includes KZ           KYZ  KSZ  KMZ   TZ  CZ NO conversion    51 ZCP Zone Compare Move and Compare 9 0   oe   A Operand includes KZ  KV                   KSZ  KMZ   TZ  TV        CV  NO  conversion    52 ZCPP Zone Compare Move and Compare ee oe   A Operand includes KZ  KV           KYZ  KSZ  KMZ   TZ  TV        CV  NO  conversion    53 DZCP Zone Compare Move and Compare ee oe   A Operand includes KZ                   KSZ  KMZ                   conversion    54 DZCPP Zone Compare Move and Compare eo oe   A Operand includes KZ                   KSZ  KMZ   TZ  CZ NO conversion    55 MOV Move
46. ion Arithmetic and 9 0   eo e A Operand includes KZ  KV   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion   85 DADD Addition Arithmetic and 9 eo eo e A Operand includes KZ   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   86 DADDP Addition Arithmetic and 9 0   eo e A Operand includes KZ   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   87 SUB Subtraction Arithmetic and 9 0 eo   A Operand includes KZ  KV   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion   88 SUBP Subtraction Arithmetic and 9 0 eo e A Operand includes KZ  KV   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion   89 DSUB Subtraction Arithmetic and 9 0 eo eO A Operand includes KZ   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   90 DSUBP Subtraction Arithmetic and 9 eo eo e A Operand includes KZ   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  CZ  NO conversion   91 MUL Multiplication Arithmetic and 9 0 eo e A Operand includes KZ  KV   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion   92 MULP Multiplication Arithmetic and 9 0   eo e A Operand includes KZ  KV   Logical operations KXZ  KYZ  KSZ  KMZ   TZ  TV  CZ  CV  NO  conversion                                   30 54       Ladder Program Converter Operation Manual                                                                                                 7 5 Fx   Fx   Fx   Fx   Convert  No  Instruction Function Class 3 2  1  
47. ion Arithmetic and 919 A Operand includes address  Logical operations out of converter range and  KY  KM  KS  TV  TZ   CV  CZ  DV  DZ  KYZ   KSZ  KMZ  NO  conversion   To CP1E  NO conversion   123   ROR Rotation Right Rotation and Shift e eoe x  Operation  124   RORP Rotation Right Rotation and Shift 919     Operation  125   DROR Rotation Right Rotation and Shift 919     Operation  126   DRORP Rotation Right Rotation and Shift e eoe x  Operation  127   ROL Rotation Left Rotation and Shift 919     Operation  128   ROLP Rotation Left Rotation and Shift 919     Operation  129   DROL Rotation Left Rotation and Shift 919     Operation  130   DROLP Rotation Left Rotation and Shift 919     Operation  131   RCR Rotation Right with   Rotation and Shift 919     Carry Operation  132   RCRP Rotation Right with   Rotation and Shift 919     Carry Operation  133   DRCR Rotation Right with   Rotation and Shift 919     Carry Operation                                  32154       Ladder Program Converter Operation Manual                                                                                                             Convert        Instruction Function Class 3 2  1     1S   Status Remark  134   DRCRP Rotation Right with   Rotation and Shift 919     Carry Operation  135   RCL Rotation Left with Rotation and Shift e e x  Carry Operation  136   RCLP Rotation Left with Rotation and Shift 919     Carry Operation  137   DRCL Rotation Left with Rotation and Shift 919     Carry Operation  13
48. l FX I O 919     Devices  212   HKY Hexadecimal Input External FX I O 919     Devices  213   DHKY Hexadecimal Input External FX I O 919     Devices  214   DSW Digital Switch External FX I O 9 0 eo e x  Devices  215   SEGD Seven Segment External FX I O         x  Decoder Devices  216   SEGDP Seven Segment External FX I O 919     Decoder Devices  217   SEGL Seven Segment External FX I O 9 0   eo e x  With Latch Devices  218   ARWS Arrow Switch External FX I O e e x  Devices  219   ASC ASCII Code External FX I O 919     Devices  220   PR Print  To A Display External FX I O 919     Devices  221   FROM Read From A External FX I O 919 9     Special Function Devices  Block  222   FROMP Read From A External FX I O         e x  Special Function Devices  Block  223   DFROM Read From A External FX      919 9     Special Function Devices  Block  224   DFROMP Read From A External FX      919 9     Special Function Devices  Block  225   TO Write To A Special External FX      e  oe    x  Function Block Devices  226   TOP Write To A Special External FX      6   eo        Function Block Devices  227   DTO Write To A Special External FX      6 0       Function Block Devices  228   DTOP Write To A Special External FX      e  oe    x  Function Block Devices  229   RS RS External FX Serial 919 99     Communications Devices  230   PRUN Parallel run External FX Serial 919 99     Devices  231   PRUNP Parallel run External FX Serial       99     Devices  232   DPRUN Parallel run External FX Serial e 
49. lse Y output High Speed 9 0   eo e x  Processing  192   PWM Pulse width High Speed ee oe 0 x  modulation Processing  193   PLSR Ramp Pulse output   High Speed 9 0   eo e x  Processing  194   DPLSR Ramp Pulse output   High Speed 9 0   eo e x  Processing                                     34154    Ladder Program Converter Operation Manual                                                                                                                              5 Fx   Fx   Fx   Fx   Convert  No  Instruction Function Class 3 2 AN   4S   Status Remark  195   IST Initial State Handy Instructions 9 0   0          196   SER Search Handy Instructions 9019     197   SERP Search Handy Instructions         x  198   DSER Search Handy Instructions         x  199   DSERP Search Handy Instructions         x  200   ABSD Absolute Drum Handy Instructions 9 0   eo e x  201   DABSD Absolute Drum Handy Instructions 9 0   eo        202   INCD Incremental Drum Handy Instructions 9 0   0          203   TTMR Teaching Timer Handy Instructions         x  204   STMR Special Timer   Handy Instructions 919     Definable  205   ALT Altermate State Handy Instructions 9 0             206            Altermate State Handy Instructions 9 0             207   RAMP Ramp Variable Handy Instructions 9 0 eo e x  Value  208   ROTC Rotart Table Handy Instructions 919     Control  209   SORT Sort Data Handy Instructions 919     210          Ten Key Input External FX I O 919     Devices  211   DTKY Ten Key Input Externa
50. mpanies     5154       Ladder Program Converter Operation Manual    Safety Precautions       Definition of Precautionary Information   The following notation is used in this manual to provide precautions required to ensure safe usage of Ladder  Program Converter  CX Programmer and Programmable Logic Controller  PLC   The safety precautions  that are provided are extremely important to safety  Always read and heed the information provided in all  safety precautions        Indicates an imminently hazardous situation which   AX AR if not avoided  will result in death or serious injury   Additionally  there may be severe property damage           Indicates a potentially hazardous situation which        2 8 if not avoided  may result in minor or moderate          injury  or property damage        Precautions for Safe Use  Indicates precautions on what to do and what not to do to ensure using the product safely     Precautions for Correct Use  Indicates precautions on what to do and what not to do to ensure proper operation and performance     Additional Information    Additional information to increase understanding or make operation easier     Symbols    The triangle symbol indicates precautions  including  warnings   The specific operation is shown in the  triangle and explained in text  This example indicates  a precaution for electric shock     The circle and slash symbol indicates operations that  you must not do  The specific operation is shown in    the circle and explained
51. n Logarithm  295   DESQR Floating Point Floating Point            CP1E No Conversion   Square Root  296   DESQRP Floating Point Floating Point e    A To CP1E No Conversion   Square Root  297   DENEG Floating Point Floating Point e x  Negation  298   DENEGP Floating Point Floating Point e x  Negation  299   INT Floating Point to Floating Point e oe O          Integer                               37154    Ladder Program Converter Operation Manual                                                                                                                                       Fx   Convert        Instruction Function Class 3 2  4AN   1S   Status Remark  300   INTP Floating Point to Floating Point e oe O  Integer  301   DINT Floating Point to Floating Point e    O  Integer  302   DINTP Floating Point to Floating Point e oe O  Integer  303   DSIN Sine Floating Point         A To CP1E No Conversion   304   DSINP Sine Floating Point 919 A To CP1E No Conversion   305   DCOS Cosine Floating Point 9019 A To CP1E No Conversion   306   DCOSP Cosine Floating Point         A To CP1E No Conversion   307   DTAN Tangent Floating Point         A To CP1E No Conversion   308   DTANP Tangent Floating Point         A To CP1E No Conversion   309   DASIN Floating Point Arc Floating Point e A To CP1E No Conversion   Sine  310   DASINP Floating Point Arc Floating Point e A To CP1E No Conversion   Sine  311   DACOS Floating Point Arc Floating Point e A To CP1E No Conversion   Cosine  312   DACOSP Fl
52. ndom Number Others e x  Generation  391   RNDP Random Number Others e x  Generation  392   DUTY Timing Pulse Others e x  Generation  393   CRC Cyclic Redundancy   Others e x  Check  394   CRCP Cyclic Redundancy   Others e x  Check  395   DHCMOV High Speed Others e x  Counter Move  396   ADPRW Adapter Others e x  397   BK  Block Data Addition   Block Data Operation   6 x  398   BK P Block Data Addition   Block Data Operation   6 x  399   DBK  Block Data Addition   Block Data Operation      x  400   DBK P Block Data Addition   Block Data Operation   6 x  401   BK  Block Data Block Data Operation   6 x  Subtraction          40   54    Ladder Program Converter Operation Manual                                                                                                                                        Convert         Instruction Function Class 3 2  1     1S   Status Remark   402   BK P Block Data Block Data Operation   6 x  Subtraction   403   DBK  Block Data Block Data Operation   6 x  Subtraction   404   DBK P Block Data Block Data Operation   6 x  Subtraction   405   BKCMP  Block Data Block Data Operation   6 x  Compare S1 S2   406   BKCMP P Block Data Block Data Operation   6 x  Compare S1 S2   407   DBKCMP  Block Data Block Data Operation   6 x  Compare S1 S2   408   DBKCMP P Block Data Block Data Operation   6 x  Compare S1 S2   409   BKCMP gt  Block Data Block Data Operation   6 x  Compare S1 gt S2   410   BKCMP gt P Block Data Block Data Operation   6 x  Compare S
53. ng Control 9 0   0          347   DDRVI Drive to increment Positioning Control 9 0   oo e x  348   DDRVA Drive to absolute Positioning Control 9 0      e     349   DRVA Drive     absolute Positioning Control 96 0   0          350            Time Compare Real Time clock 9 0 eo e x  Control  351   TCMPP Time Compare Real Time clock 9 0 eo e x  Control  352   TZCP Time Zone Real Time clock 919 99     Compare Control  353   TZCPP Time Zone Real Time clock 919 99     Compare Control  354   TADD Time Add Real Time clock e e e e x  Control  355   TADDP Time Add Real Time clock 919 99     Control  356   TSUB Time Subtract Real Time clock 919 99     Control  357   TSUBP Time Subtract Real Time clock 919 99     Control  358   HTOS Hour to second Real Time clock e x  conversion Control  359   HTOSP Hour to second Real Time clock e x  conversion Control  360   DHTOS Hour to second Real Time clock e x  conversion Control  361   DHTOSP Hour to second Real Time clock e x  conversion Control  362   STOH Second to hour Real Time clock e x  conversion Control  363   STOHP Second to hour Real Time clock e x  conversion Control  364   DSTOH Second to hour Real Time clock e x  conversion Control  365   DSTOHP Second to hour Real Time clock e x  conversion Control  366   TRD Read RTC data Real Time clock 919 99     Control                                     39  54    Ladder Program Converter Operation Manual                                                                                          
54. nstruction  253   MCDEP Machine Code Special Module e x  Instruction  254   MNET Mini Net Special Module e x  Instruction  255   MNETP Mini Net Special Module e x  Instruction  256   RMMN RM Monitor Special Module e x  Instruction  257   RMMNP RM Monitor Special Module e x  Instruction  258   RMRD RM Read Special Module e x  Instruction  259   RMRDP RM Read Special Module e x  Instruction  260   RMST RM Start Special Module e x  Instruction  261   RMWR RM Write Special Module e x  Instruction  262   RMWRP RM Write Special Module e x  Instruction  263   ZPUSH Batch Store of Data Transfer 2 e x  Index Register  264   ZPUSHP Batch Store of Data Transfer 2 e x  Index Register  265   ZPOP Batch POP of Index   Data Transfer 2 e x  Register  266   ZPOPP Batch POP of Index   Data Transfer 2 e x          Register                               36 54    Ladder Program Converter Operation Manual                                                                                                             3                         Fx   Convert        Instruction Function Class 3 2  1     1S   Status Remark  267   DECMP Floating Point Floating Point 919     Compare  268   DECMPP Floating Point Floating Point e e x  Compare  269   DEZCP Floating Point Zone   Floating Point       x  Compare  270   DEZCPP Floating Point Zone   Floating Point 919     Compare  271   DEMOV Floating Point Floating Point e O  Move  272   DEMOVP Floating Point Floating Point e O  Move  273   DESTR Floating Point to Fl
55. nstructions   And Not immediate O  12 Ol Bit Logic Instructions Or immediate O  13 ONI Bit Logic Instructions Or Not immediate O  14 ALD Bit Logic Instructions   And Block O  15 OLD Bit Logic Instructions Or Block O  16 NOT Bit Logic Instructions   Not O  17 EU Bit Logic Instructions   Pulse O  18 ED Bit Logic Instructions Falling Pulse O  19    Bit Logic Instructions   Output O   20    Bit Logic Instructions Output immediate O   21 S Bit Logic Instructions   Set O   22 R Bit Logic Instructions Reset O   23 SI Bit Logic Instructions Set immediate x   24 RI Bit Logic Instructions Reset immediate x   25 SR Bit Logic Instructions Set Dominant Bistable O   26 RS Bit Logic Instructions           Piste x   instruction  27 NOP Bit Logic Instructions Nop x  28 LDB  Compare Instructions   Compare Load Byte N1 N2 O  29 LDB lt  Compare Instructions   Compare Load Byte N1 lt N2 O  30 LDB gt  Compare Instructions   Compare Load Byte N1 gt N2 O  31 LDB lt  gt  Compare Instructions   Compare Load Byte N1 lt  gt N2 O  32 LDB lt   Compare Instructions   Compare Load Byte N1 lt  N2 O  33 LDB gt   Compare Instructions   Compare Load Byte N1 gt  N2 O  34 LDW  Compare Instructions   Compare Load Word N1 N2 O  35 LDW lt  Compare Instructions   Compare Load Word N1 lt N2 O  36 LDW gt  Compare Instructions   Compare Load Word N1 gt N2 O  37 LDW  lt  gt  Compare Instructions   Compare Load Word N1 lt  gt N2 O  38 LDW lt   Compare Instructions   Compare Load Word N1 lt  N2 O  39 LDW gt   Compare Instr
56. nstructions   Compare And String IN1 IN2 x  103   AS lt  gt  Compare Instructions   Compare And String IN1 lt  gt IN2 x  104   OS  Compare Instructions   Compare Or String IN1 IN2 x  105   OS lt  gt  Compare Instructions   Compare Or String IN1 lt  gt IN2 x  106   TON Timer Instructions On Delay Timer O  107   TONR Timer Instructions Retentive On Delay Timer O  108   TOF Timer Instructions Off Delay Timer x  109   TP Timer Instructions Pulse Timer x  110   BGN ITIME   Timer Instructions Beginning Interval Time x  111 CAL ITIME   Timer Instructions Calculate Interval Time x  112   CTU Counter Instructions CU increments the current value O  CU increments the current value  113   CTUD Counter Instructions CD decrements the current O  value  114   CTD Counter Instructions CD decrements QS LUD  O  value  115   ADDI Math Instructions Add Integer IN1 OUT OUT O  116   SUBI Math Instructions Subtract Integer IN1 OUT OUT O  117   ADD_DI Math Instructions oa O  118   SUB_DI Math Instructions Subtract Integer IN1 OUT OUT O  119   MULI Math Instructions Multiply Interger IN1 OUT OUT     120   DIV  Math Instructions Divide Interger IN1 OUT OUT O  Multiply Double Interger  121   MUL_DI Math Instructions IRI      9     Divide Double Interger  122  DIV_DI Math Instructions INOURZOUT g O  123   MUL Math Instructions ae ae     124   DIV Math Instructions Divide Interger  16 16   32  O                         50 54    Ladder Program Converter Operation Manual                                     
57. oating Point Arc Floating Point e AN      CP1E No Conversion   Cosine  313   DATAN Floating Point Arc Floating Point e A To CP1E No Conversion   Tangent  314   DATANP Floating Point Arc Floating Point e A To CP1E No Conversion   Tangent  315   DRAD Floating Point Floating Point e A To CP1E No Conversion   Degrees to  Radians  Conversion  316   DRADP Floating Point Floating Point e A To CP1E No Conversion   Degrees to  Radians  Conversion  317   DDEG Floating Point Floating Point e A To CP1E No Conversion   Radians to  Degrees  Conversion  318   DDEGP Floating Point Floating Point e A To CP1E No Conversion   Radians to  Degrees  Conversion  319   WSUM Sum of Word Data Data Operation 2 e x  320   WSUMP Sum of Word Data Data Operation 2 e x  321   DWSUM Sum of Word Data Data Operation 2 e x  322   DWSUMP Sum of Word Data Data Operation 2 e x  323   WTOB WORD to BYTE Data Operation 2 e x  324   WTOBP WORD to BYTE Data Operation 2 e x  325   BTOW BYTE to WORD Data Operation 2 e x  326   BTOWP BYTE to WORD Data Operation 2 e x  327   UNI 4 bit Linking of Data Operation 2 e x  Word Data  328   UNIP 4 bit Linking of Data Operation 2 e x  Word Data  329   DIS 4 bit Grouping of Data Operation 2 e x  Word Data  330   DISP 4 bit Grouping of Data Operation 2 e x  Word Data  331   SWAP Float to Scientific Data Operation 2 919 AN Operand includes address  out of converter range and  KY  KM  KS  TV  TZ   CV  CZ  DV  DZ           KSZ  KMZ  NO  conversion   332   SWAPP Float to Scientific Data
58. oating Point e x  Character String  Conversion  274   DESTRP Floating Point to Floating Point e x  Character String  Conversion  275   DEVAL Character String to   Floating Point e O  Floating Point  Conversion  276   DEVALP Character String to   Floating Point e O  Floating Point  Conversion  277   DEBCD Floating Point to Floating Point 919     Scientific  278   DEBCDP Floating Point to Floating Point 919     Scientific  279   DEBIN Scientific to Floating Point 919     Floating Point  280   DEBINP Scientific to Floating Point         x  Floating Point  281   DEADD Floating Point Add Floating Point 9 9 O  282   DEADDP Floating Point Add Floating Point 9 9 O  283   DESUB Floating Point Floating Point e    O  Subtract  284   DESUBP Floating Point Floating Point e    O  Subtract  285   DEMUL Floating Point Floating Point e    O  Multiplication  286   DEMULP Floating Point Floating Point e    O  Multiplication  287   DEDIV Floating Point Floating Point e oe O  Division  288   DEDIVP Floating Point Floating Point e    O  Division  289   DEXP Floating Point Floating Point e A To CP1E No Conversion   Exponent  290   DEXPP Floating Point Floating Point e A To CP1E No Conversion   Exponent  291   DLOGE Floating Point Floating Point e AN To CP1E No Conversion   Natural Logarithm  292   DLOGEP Floating Point Floating Point e A To CP1E No Conversion   Natural Logarithm  293   DLOG10 Floating Point Floating Point e x  Common Logarithm  294   DLOG10P Floating Point Floating Point e x  Commo
59. om the Right KX  KY  KM  KS  TV   TZ        CZ  DV  DZ           KYZ  KSZ           NO conversion   To CP1E No Conversion   443   LEFT Extracting Character String e A Operand includes address  Character String Control out of converter range and  Data from the Left KX  KY  KM  KS  TV   TZ        CZ  DV  DZ           KYZ  KSZ           NO conversion   To CP1E No Conversion   444   LEFTP Extracting Character String e A Operand includes address  Character String Control out of converter range and  Data from the Left KX  KY  KM  KS  TV   TZ        CZ  DV  DZ           KYZ  KSZ           NO conversion   To CP1E No Conversion   445   MIDR Random Selection Character String e x  of Character Control  Strings  446   MIDRP Random Selection Character String e x  of Character Control  Strings  447   MIDW Random Character String e x  Replacement of Control  Character Strings  448   MIDWP Random Character String e x  Replacement of Control  Character Strings  449   INSTR Character string Character String e x  search Control  450   INSTRP Character string Character String e x  search Control  451    MOV Character String Character String e O To CP1E No Conversion   Transfer Control                                  42154       Ladder Program Converter Operation Manual                                                               5 Fx   Fx   Fx   Fx   Convert  No  Instruction Function Class 3 2  1     1S   Status Remark  452    MOVP Character String Character String e O To CP1E No Conversion   
60. overnment regulations     e Systems  machines  and equipment that could present a risk to life or property   Please know and observe all prohibitions of use applicable to the products     NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR  PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO  ADDRESS THE RISKS  AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM     4  CHANGE IN SPECIFICATIONS  Product specifications and accessories may be changed at any time based on improvements and other  reasons     4154    Requirement of configuration  Environment of the converter can be installed    Ladder Program Converter Operation Manual       Microsoft Windows 2000    Microsoft Windows Vista       Service Pack2 or higher Microsoft Windows XP  32bit version   Pentium series CPU Pentium series CPU  150MHz or better CPU 300MHz or better CPU Microsoft recommended    Pentium IIl 1GHz or better    Pentium  1 1GHz or better    configuration  1GHz or       CPU central processors central processors better CPU   Must be 512MB or more  Memory  RAM  256MB or more 384MB or more 1GB or more is better          Hard drive space       50MB of free       50MB of free       50MB of free       Trademarks    Windows is a registered trademark of Microsoft Corporation     Other system names and product names in this document are the trademarks or registered trademarks  of their respective co
61. p symbol for converting Sienens program  Destination  NOV  021  Nove       DO    Source word    TENP_CH_02 This iz a tenp symbol for converting Siewens program  Destination       El  AND  034  Logical AND Mord  5 Input 1  K000F Input 2  TENP_CH_03 This is a tenp zynbol for converting Siemens program  Result word     410  Signed Binary Subtract Without Garry     10 Ninuend word    TENP_CH_03 5 a tenp synbol for converting Sienens program    This i  Subtrahend word    TENP  CH 04 This is a tenp symbol for converting Siemens program   Result word          NASL  580  Shift N Bits Left    i   5 TENP GH 01 This ie a temo swubol for converting Siemens oroeran  gt   Project          gt   x WEST TE Compile A Find Report A  Transfer 7 E E    For Help  press Fl    NewPLC1 Wet  0  Node 0    Offline rung 0  2  15    90  Classic                                                 Fig  5 17 the result of conversion    23154    Ladder Program Converter Operation Manual     10 Insert the temporary variables created during the conversion into the global variable table           File Edit Vier Insert Program PLO Simulation Tools Window Help    vue  u on zu                              NewProject   P 0 02s BOOL CF103 Work 0 02 second clock pulse bit     88  WevPLCL  CPIE  Offline   POs BOOL CF100 Work 0 1 second clock pulse bit    Symbols   P_O_2s BOOL CF101 Work 0 2 second clock pulse bit   5  Settings   P_imin BOOL CF104 Work 1 minute clock pulse bit   9 Memory E Pis BOOL CF102 Work 1 0 second clo
62. pare Instructions   Compare OrWord N1 N2 O  83 OW lt  Compare Instructions   Compare Or Word N1 lt N2 O  84 OW  Compare Instructions   Compare Or Word N1 gt N2 O                         49 154    Ladder Program Converter Operation Manual                                                                                                                                  No  ak Class Function      Remark  85 OW lt  gt  Compare Instructions   Compare OrWord N1 lt  gt N2 O  86 OW lt   Compare Instructions   Compare Or Word N1 lt  N2 O  87 OW gt   Compare Instructions   Compare OrWord N1  gt N2 O  88 OD  Compare Instructions Compare Or Double Word O  N1 N2  89 OD lt  Compare Instructions Compare  Or Double  NO O  N1 lt N2  90 OD gt  Compare Instructions            O  N1 gt N2  91 OD lt  gt  Compare Instructions Compare  Or Double Wor O  N1 lt  gt N2  92 OD lt   Compare Instructions SENDE Double Word O  N1 lt  N2  93 OD gt   Compare Instructions DEN O  N1 gt  N2  94 OR  Compare Instructions   Compare Or Real N1 N2 O  95 OR lt  Compare Instructions   Compare Or Real N1 lt N2 O  96 OR gt  Compare Instructions   Compare Or Real N1 gt N2 O  97 OR lt  gt  Compare Instructions   Compare Or Real N1 lt  gt N2 O  98 OR lt   Compare Instructions   Compare Or Real N1 lt  N2 O  99 OR gt   Compare Instructions   Compare Or Real N1 gt  N2 O  100   LDS  Compare Instructions   Compare Load String IN1 IN2 x  101 LDS lt  gt  Compare Instructions   Compare Load String IN1 lt  gt IN2 x  102   AS  Compare I
63. py unit is one Network    Because the Channel length of Siemens is different from that of MONRON  Siemens channel length is 8    bits  while OMRON channel length is16 bits  the Error will occur during the conversion  Please pay    more attention to it     4 2  Conversion Limition     1  About Siemens Instructions        Problem    Detail       OB Series can not be  converted    Converting will break the LD s structure  so it can not be converted        TON    Because of the different Resolution  the Tim Number will change  after converted        TONR function is changed  after being converted    When set value is arrived  OMRON TIM will stop and Siemens TIM  will continue       DIV    It occur address across problem after converted        SBR CALL    It s a subroutine instruction   In Siemens  SBR CALL is used to jump to the subroutine section  directly  the section number is regarded as the sign     In OMRON  it jumps from SBS to SBN  SBN is regarded as the sign        Float can not be converted  directly    The OMRON PLC doesn t support float constant  so it can not be  converted           Flag SM1 1 can not be  converted       The Flag SM1 10f Siemens needs the special Flags  P CY  P OF  and P UF  of OMRON to correspond           10 54    Ladder Program Converter Operation Manual     2  About Mitsubishi Instructions              Problem Detail   Mitsubishi area X Y Each point of Mitsubishi area X Y corresponds a physical I O   Omron area CIO Not every point of Omron area C
64. ranl  00       Symbols    373         Sectionl         Em    Project      For Help  press Fi NewPLC1  Net 0  Node 0    Offline rung 0  0  0        Fig 5 3 OMRON CX Programmer View     5  Paste the source program in the Diagram view or Mnemonics view  And the following dialogue box will    be displayed         Ladder Program Converter Verl 2    Caution    This software is only a supporting tool for ladder program  conversion  So you should review and debug the conversion  result in real application          Source PLO Type                      V Generate a conversion list    File path of the conversion list       Browse         Fig  5 4 Ladder Conversion Dialogue box    14154    Ladder Program Converter Operation Manual     6  Click the Browse Button  designate the name and path of conversion list file  Fig 5 5     Save in      My Documents        xm  Amy Music     a My Pictures             Save as type   Converting list file    csv     Cancel    7       Fig  5 5 Conversion list file saving dialogue box     7  Select the conversion source PLC type  Click the OK Button and the Converting progress bar will be    displayed              Fig  5 6Converting progress bar    15 54    Ladder Program Converter Operation Manual     8  The converted program will be displayed in the CK Programmer              new   CX Programmer    NewPLC1   55 File Edit View Insert Program PLC Simulation Tools Window Help          Do       R Sa sem al2e   d ze 25  5   M     A 08    n  s n  xa  11515 kar  
65. rter Operation Manual       No     Instruction    Function    Class    Fx    Fx  1N    Fx  1S    Convert  Status    Remark       482    ANDD lt  gt      S1   S2     Inline Comparisons    A    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        483    AND        S1          52     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        484    ANDD lt       S1          52     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ         TV  CZ  CV  DZ  DV  NO  conversion        485    AND gt       S1          52     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        486    ANDD gt       S1 0        S2     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        487    OR      S1   S2     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        488    ORD      S1   S2     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        489    OR       S1  gt  S1     Inline Comparisons    Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion        490    ORD gt      S1  gt  S1 
66. t  Compare Instructions   Compare And Word N1 lt N2 O  60 AW gt  Compare Instructions   Compare And Word N1 gt N2 O  61 AW  lt  gt  Compare Instructions   Compare And Word N1 lt  gt N2 O  62 AW lt   Compare Instructions   Compare And Word N1 lt  N2 O  63 AW gt   Compare Instructions   Compare And Word N1  gt N2 O  64 AD  Compare Instructions Compare And Doubleorg O  N1 N2  65 AD lt  Compare Instructions Compare And                         O  N1 lt N2  66 AD gt  Compare Instructions Compare And  Double Word O  N1 gt N2  67 AD lt  gt  Compare Instructions Compare And Double Worda O  N1 lt  gt N2  68 AD lt   Compare Instructions Compare And Double Word O  N1 lt  N2  69 AD gt   Compare Instructions Compare And Double Word O  N1 gt  N2  70 AR  Compare Instructions   Compare And Real N1 N2 O  71 AR lt  Compare Instructions   Compare And Real N1 lt N2 O  72 AR gt  Compare Instructions   Compare And Real N1 gt N2 O  73 AR lt  gt  Compare Instructions   Compare And Real N1 lt  gt N2 O  74 AR lt   Compare Instructions   Compare And Real N1 lt  N2 O  75 AR gt   Compare Instructions   Compare And Real N1 gt  N2 O  76 OB  Compare Instructions   Compare Or Byte N1 N2 O  77 OB lt  Compare Instructions   Compare Or Byte N1  N2 O  78 OB gt  Compare Instructions   Compare Or Byte N1 gt N2 O  79 OB lt  gt  Compare Instructions   Compare Or Byte N1 lt  gt N2 O  80 OB lt   Compare Instructions   Compare Or Byte N1 lt  N2 O  81 OB gt   Compare Instructions   Compare Or Byte N1 gt  N2 O  82 OW  Com
67. tions   171 ROL_B Snitt ana Rotate Rotate Left Byte x  Instructions   172   ROR W Snin ang Rotate Rotate Right Word O    Instructions   173   ROL W Shift and Notate Rotate Left Word O    Instructions   174   RoR pw   Shift and Rotate Rotate Right Double Word O    Instructions   175  ROL DW Shift ang Rotate Rotate Left Double Word O    Instructions   176   SHRB Shift and Rotate Shift and Rotate Register x  Instructions   177   BCD  N BCD to integer O  Instructions   178    _ BCD nel Integer to BCD O  Instructions   179   DI_R DTR  Conversion Double Integer to Real O  Instructions   180   ROUND Conversion Round     Instructions   181   TRUNC Conversion Truncate O  Instructions   182   DII Conversion Double Integer to Integer x  Instructions   183   IDI Gonversion Integer to Double Integer O    Instructions   184  BI Conversion Byte to Integer x  Instructions   185    B conversion Interger to byte x  Instructions   186   DECO Conversi  n Decode O  Instructions   187   ENCO Sonversion Encode O  Instructions   188   SEG Conversion Segment O  Instructions   189   ATH Gonverion ASCII to Hexadecimal x  Instructions   190   HTA Conversion Hexadecimal to ASCII x  Instructions   191 ITA Solan Integer to ASCII x  Instructions   192   DTA Conversion Double Integer to ASCII x  Instructions   193   RTA eo eh Real to ASCII x  Instructions   194    5 ponen Integer to String x  Instructions                         52154    Ladder Program Converter Operation Manual                              
68. uctions   Compare Load Word N1 gt  N2 O  40 LDD  Compare Instructions Compare Load Double NOR O  N1 N2   41 LDD lt  Compare Instructions Compare Load Double Word O  N1 lt N2   42 LDD gt  Compare Instructions s      O          48   54    Ladder Program Converter Operation Manual                                                                                                                                        No     Class Function a Remark  43 LDD lt  gt  Compare Instructions CompareLoad Double  Werna O  N1 lt  gt N2  44 LDD lt   Compare Instructions Compare load Double Wong O  N1 lt  N2  45 LDD gt   Compare Instructions Compare Load Double Word O  N1 gt  N2  46 LDR  Compare Instructions   Compare Load Real N1 N2 O  47 LDR lt  Compare Instructions   Compare Load Real N1 lt N2 O  48 LDR gt  Compare Instructions   Compare Load Real N1 gt N2 O  49 LDR lt  gt  Compare Instructions   Compare Load Real N1 lt  gt N2 O  50 LDR lt   Compare Instructions   Compare Load Real N1 lt  N2 O  51 LDR gt   Compare Instructions   Compare Load Real N1 gt  N2 O  52 AB  Compare Instructions   Compare And Byte N1 N2 O  53 AB lt  Compare Instructions   Compare And Byte N1 lt N2 O  54 AB gt  Compare Instructions   Compare And Byte N1 gt N2 O  55 AB lt  gt  Compare Instructions   Compare And Byte N1 lt  gt N2 O  56 AB lt   Compare Instructions   Compare And Byte N1 lt  N2 O  57 AB gt   Compare Instructions   Compare And Byte N1 gt  N2 O  58 AW  Compare Instructions   Compare And Word N1 N2 O  59 AW l
69. udes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ         TV  CZ  CV  DZ  DV  NO  conversion   498   ORD gt    S1 I S2  Inline Comparisons eo eo e A Operand includes KZ  KV   KX  KY  KS  KM  KXZ   KYZ  KSZ  KMZ  TZ   TV  CZ  CV  DZ  DV  NO  conversion   499   LIMIT Limit Control Data Table Operation   9 x  500   LIMITP Limit Control Data Table Operation   9 x  501   DLIMIT Limit Control Data Table Operation   9 x  502   DLIMITP Limit Control Data Table Operation   9 x  503   BAND Dead Band Control   Data Table Operation   9 x  504   BANDP Dead Band Control   Data Table Operation   6 x  505   DBAND Dead Band Control   Data Table Operation   6 x  506   DBANDP Dead Band Control   Data Table Operation   6 x  507   ZONE Zone Control Data Table Operation   9 x  508   ZONEP Zone Control Data Table Operation   9 x  509   DZONE Zone Control Data Table Operation   9 x  510   DZONEP Zone Control Data Table Operation   9 x  511   SCL Scaling Data Table Operation   6 x   Coordinate by  Point Data   512   SCLP Scaling Data Table Operation   6 x   Coordinate by  Point Data   513   DSCL Scaling Data Table Operation   6 x   Coordinate by  Point Data   514   DSCLP Scaling Data Table Operation   6 x   Coordinate by  Point Data   515   DABIN Decimal ASCII to Data Table Operation   6 x  BIN  Conversion  516   DABINP Decimal ASCII to Data Table Operation   6 x  BIN  Conversion  517   DDABIN Decimal ASCII to Data Table Operation   6 x  BIN  Conversion  518   DDABINP Decimal ASCII to Data Table Oper
    
Download Pdf Manuals
 
 
    