Home

Smart Thermostat (CT100)

image

Contents

1. 1 F D N Touch Hi to return to the MENU screen a Chirp set Touch this to turn the audible chirp sound on or off F oc Set Touch this to switch the temperature display scale from OF to OC o LOCK The CT100 has 2 lock modes Touch icon for 5 seconds the unit will go into the PARTIAL lock mode The user can temporarily override the CT100 target with the buttons only 1 bar For FULL lock Touch the 1 bar icon again for 5 seconds to go to full lock No changes can be made in full lock 8 2 bars Once locked the CT100 will respond just to MENU To UNLOCK Press MENU Touch and hold amp icon for 5 seconds for 2 bars if not there already Then touch and hold the icon for another 5 seconds Each 5 second touch and hold must be separate Touch to return to the Home screen PG 7 CALIBRATE Your thermostat was accurately calibrated at the factory to 1 F of actual ambient temperature You do have the option however to change the display temperature to match that of a previous thermostat or to match another thermostat already in your home The range of change is from 6 F to 6 F or 3 C to 3 C To change your Thermostat Calibration touch MENU and then touch CALIBRATE Use the to adjust the displayed temperature up or down as desired The DELTA FACTOR that appears on the screen will also automatically increase or decrease for each 0 5 F or C adjustment so you can see your change The l
2. Operation Guide CT100 The CT100 communicating Z Wave thermostat operates via a high quality easy to use touch screen To set or adjust your CT100 simply touch your finger firmly to the screen The screen will automatically light up and you will hear a beep Do not use a sharp or metallic device it will scratch the screen Statement of use 100 Compatible with all popular residential HVAC systems 24VAC single two stage conventional heating systems gas oil electric heat pumps with up to two stages of heat and two stage auxiliary heat electric or fossil zoned forced air and zoned hot water 2 or 3 wire millivolt systems with a 12 24 AC or DC source one or two stage cooling and hybrid systems 1202 002 002 PG 1 nadie Tpemnose Radio Thermostat Company of America ENGLISH PG 2 HOME Screen Before you operate the CT100 please get familiar with these basic control screens All the CT100 functions are accessed through these screens HOME MENU and MANUAL The CT100 touch screen technology allows you to select by touching an item and change it using the arrows or the time arrows Current Room The HOME screen is displayed Time when the unit is operating Touching of Day Temperature eae the HOME icon Mi on another 790 y screen will always return you to this ic icb screen To set a Mode Temperature Press the mode button on the front l gt Controls The CT100 will step thro
3. arge display will show the modified temperature reading that will be displayed on the HOME screen and used as the new room temperature Touch Hi to return to the Home screen DIFF Used for multiple stage systems only not on screen for single stage The differential is the number of degrees between the room temperature and the Target Temperature at which the 2nd stage will be used DIFF may be set to a different value for HEAT or COOL Default is 2 F range is 2 F to 6 F 1 3 C To set the differential for the current mode touch MENU and then DIFF Use the arrows to set the DIFF Recommend 2 F for very cold climates and 6 F for warm climates pc 8 MANUAL Screen Functions The CT100 has 2 manual override commands The manual screen is accessed by touching the large current temperature display in the middle of the HOME screen IMPORTANT The MODE must be in HEAT COOL or AUTO to access the manual screen TEMPERATURE Touch the arrows to select your desired Target Temperature Touch HOME to return to operation EMER in HEAT PUMP type If you set your CT100 for HEAT PUMP with auxiliary heat EMER function is available on the MANUAL screen If you touch EMER it displays EMERJON Your HEAT PUMP is disabled and auxiliary heat is your sole source of heat This manual override stays active until you toggle EMER off Auxiliary heat is more expensive than the heat pump so use EMER only if the heat pump cannot keep up or is defecti
4. n go back to sleep The node type is fixed during network inclusion If C Wire is not present and the thermostat is battery powered during network inclusion the thermostat will remain a frequent listening routing slave FLIRS node until the thermostat is removed from the network via network exclusion Z Wave and C Wire Power When your thermostat is running on C Wire power the Z Wave radio will stay on and actively help in routing messages within the z wave network The node type is fixed during network inclusion If C Wire is present and powered during network inclusion the thermostat will remain an always listening node until the thermostat is removed from the network via network exclusion Caution HVAC Setup and Z Wave Do not change the HVAC setup or HVAC selection switches if the thermostat is included to Z Wave network If the HVAC system must be changed first EXCLUDE the thermostat from the network change the HVAC setup and INCLUDE the thermostat to the network
5. ngs Press MENU to access the following commands from HOME screen Set time of day Touch the Time of Day arrows to move the time selection forward or backward until Pe Loga it displays the current time Touch and hold for faster setting CSi Set F C display Touch the OF and it will toggle to C oE o yo Set audible chirp Touch the musical note icon to select chirp or no chirp a ww Return HOME by touching the home icon iaia Ew pc 5 pc 6 MENU Screen Functions Press MENU to bring up MENU screen TIME of DAY Touch the left down or right up arrows next to the time display to set the current time 1 minute per touch Touch and hold the arrow for fast time set 15 minute jumps SWING HVAC cycling rate This feature allows you to set the desired variance in temperature between the CT100 setting and the room temperature required before the heating or cooling system will turn on Swing range 0 5 to 4 0 F 25 to 2 C For example if SWING is set to 2 0 F and the CT100 is set to 70 F Target Temperature the heat cycle will start when room temperature drops to 68 F Similarly the cooling system will start when the room temperature increases to 72 F The HVAC then runs and will shut off at the Target Temperature To set SWING Touch SWING Touch the left right arrows to set the SWING from 0 5 to 4 0 F 25 to 2 C The HVAC will run more frequently at 0 5 F and less at 4 0 F Default is
6. trollers User Manual for detailed instructions 2 Press and release the MENU button on the thermostat 3 Press the MATE button This will bring you to the network screen and a large r1 will be displayed 4 Press the MATE button again This will initiate the mating process When a device has joined a network the word LINK will appear under the radio tower Your controller will indicate the thermostat was successfully added to its network See your specific controller s User Manual for details Network EXCLUSION 1 Set your primary controller to EXCLUDE mode to remove the thermostat as a node on your network see your specific controller s User Manual for detailed instructions 2 Press and release the MENU button on the thermostat 3 Press the MATE button This will bring you to the network screen and a large r1 will be displayed 4 Press the MATE button this will initiate the mating process When a device has been removed from a network the word LINK below the radio tower will disappear Your controller will indicate the thermostat was successfully removed from its network see your specific controller s User Manual for details i PG pe 12 Z Wave and Battery Power When your thermostat is running on battery power the Z Wave radio will turn off to help conserve battery life The CT100 Z Wave radio module supports Z Wave beaming which allows other devices in the network to wake up the Z Wave module and accept commands and the
7. ugh the ENK 7 m modes HEAT OFF COOL OFF que a gt HA A AUTO OFF in order TARGET TEMP Radio Target ladicat Thermostat Temperature naicator Mode NOTE Icon blinks when the function is running and back light is on M EN U Screen The MENU screen is the gateway to many functions or settings of the CT100 It is displayed when you press the MENU button See page 6 for details Set Time RECOVERY set Differential to set Chirp set Touch this area to set FAST or ECON for 2nd Stage start Touch this to turn the the time of day audible chirp on or off Left arrow goes back ponhe ECON RECOVER Pi right arrow goes forward Return Temperature Swing set oe screen Lock Program RADIO icon Touch for 5 sec Shows radio status to lock or unlock and connection CALIBRATE 0N Calibration control Set Cc F HVAC SETUP Use this to calibrate your Touch this Touch this in OFF mode to LCD display to match to set temp configure the unit to work with another thermometer display units your HVAC system PG 3 pc 4 MAN UAL Screen The Manual Screen control screen is where you can make temporary changes to your CT100 s operation From the HOME screen touch the main temperature display to use this screen See page 9 for details Temp Up Temp Down arrows Touch these to raise and lower the manual override Target Temp Return HOME Room EMER heat for Target Temperature HEAT PUMP systems Temperature Initial Setti
8. ve Pe 9 pc 10 Other Functions MODE Button The mode button sets the CT100 to HEAT COOL AUTO or OFF modes Press it once to step to the next mode If the CT100 is in OFF and you want to return to the mode you were previously in touch the OFF indicator on screen FAN Button The fan control is normally in AUTO mode meaning that the fan operates automatically with the HVAC system and the thermostat When the fan button is pressed the fan goes ON the fan will run continuously in this manual override until switched back to AUTO by pressing the FAN button again NOTE Fan ON function is available in the OFF mode to allow simple ventilating RESET button The RESET button re boots the CT100 processor It does not effect the target temperatures that have been stored in permanent memory Compressor Protection The CT100 has a minimum cycle time of 4 minutes to protect your compressor in cool and in heat pump if you have one The Home screen will show a small clock icon during this time and the compressor will not come on until the 4 minute delay is over RH Display To display relative humidity touch the time display on the HOME screen touch again to return Communicating Thermostat The CT100 has a built in Z Wave radio This allows your thermostat to communicate with other systems Network INCLUSION 1 Set your primary controller to INCLUDE mode to add the thermostat as a node on your network see your specific con

Download Pdf Manuals

image

Related Search

Related Contents

Nokia 1661 (RH-121/RH-122) Service Manual Level 1&2  APC RS 550 Power Supply User Manual  S.H.Figuarts 仮面ライダー龍玄・黄泉 ヨモツヘグリアームズ 取扱説明書  Manuel d`utilisation de CONTACT v 1.3  Manual del usuario Bobina 18ch T/R para rodilla para sistemas de  Sony ICF-S22 User's Manual  Lig@ções virtu@is  HumidAire 2i™ User Manual  Mode d`emploi  Hobart 5212F User's Manual  